Home
Amplifiers and battery charger
Contents
1. 0359 CDP 0177 0359 CDP 0140 ATEIS A amp Mechanical Dimensions H x W x D for tabletop use with feet for 19 rack use with brackets Weight SPA 2120 SPA 2240 Mounting Colour Environmental Operating temperature Storage temperature Relative humidity Air pressure Ordering information SPA 2120 SPA 2240 92 x 440 x 305 mm 88 x 483 x 305 mm 12 3 kg 27 1 Ib 18 5 kg 40 8 Ib Standalone or 19 rackmount RAL7016 5 C to 55 C 23 F to 131 F 40 C to 70 C 40 F to 158 F 15 to 90 600 to 1100 h Pa AC Power inlet AC DC Fuse Power switch Configuration switches for EN54 16 compliances Channel 1 2 24 VDC battery backup connector Fault contact Channel 1 output Channel 1 input Channel 2 output Channel 2 input BPA BASIC POWER AMPLIFIERS MAIN CHARACTERISTICS 2 audio outputs for BPA2120 2240 and 2480 100 V 70 V 50 V selectable outputs e Fault reporting outputs e Two audio inputs with gain set Supervision of amplifiers through DIVA8 or IDA8 systems Advanced audio processing for each amplifier channel through DIVA8 or IDA8 systems Amplifier supervision and spare amplifier switching through DIVAS and IDA8 systems Louspeaker line and loudspeaker supervision through DIVA8 and IDA8 systems CONTROLS AND INDICATORS LED VU metering Status indicators for Overload Temperature control Battery and Mains INTERCONNEC
2. 0 nF 100 V 125 nF 70 V 120 W 1 min at 40 C 60 W cont at 40 C BPA2240 40 ohm 100 V 20 ohm 70 V 125 nF 100 V 250 nF 70 V 240 W 1 min at 40 C 120 W cont at 40 C BPA2480 20 ohm 100 V 10 ohm 70 V 250 nF 100 V 500 nF 70 V 480 W 1 min at 40 C 240 W cont at 40 C 120 Hz to 20 kHz 3 dB gt 90 dB no pilot tone lt 80 dB at nominal load for 1 kHz lt 1 1 kHz O 10dB of rated output Mechanical Dimensions H x W x D for tabletop use with feet for 19 rack use with brackets Weight BPA 2120 BPA 2240 BPA 2480 Mounting Colour Environmental Operating temperature Storage temperature Relative humidity Air pressure Ordering Informations BPA 2120 BPA 2240 BPA 2480 92 x 440 x 305 mm 88 x 483 x 309 mm 10 6 kg 23 3 Ib 12 3 kg 27 1 Ib 18 5 kg 4 8 Ib standalone or 19 rackmount RAL7016 5 C to 55 C 23 F to 131 F 40 C to 70 C 40 F to 158 F 15 to 90 600 to 1100 h Pa 2x 120 W 2x 240 W 2x 480 W ATEIS A AC Power inlet AC DC Fuse Power switch Configuration switches for EN54 16 compliances Channel 1 2 24 VDC battery backup connector Fault contact Channel 1 output Channel 1 input Channel 2 output Channel 2 input SONAES CHARGER AND MONITORING UNIT EN 54 4 MAIN CHARACTERISTICS Soneas 6 40 e 2U rackmount charger e 3 Auxiliary outputs max 5 Amp combined
3. ARTS INCLUDED Quantities 1 1 1 BPA BASIC POWER AMPLIFIERS Components BPA 2xxx Basic Power Amplifierr Power cord Set of mounting brackets for 19 rack set of connectors set of feet TECHNICAL SPECIFICATIONS Electrical Mains power supply Voltage Power consumption BPA 2120 BPA 2240 BPA 2480 230 VAC 10 50 60 Hz standby idle Pmax 16 W 74W 154W 28 W 150 W 322 W 64 W 287 W 655 W Idle Measured with 10 Volt surveillance tone on the output Total Mains power consumption Battery power supply Voltage Power consumption BPA 2120 BPA 2240 BPA 2480 Per ch 28 VDC 21 28 VDC standby idle Imax 0 19A 15A 3 2A 0 25A 2 9A 64A 0 30A 5 47A 12 3A Alarm cycle 10 V pilot tone 28 VDC Line inputs Connector Frequency response S N THD Input range Input impedance 2 x One per channel 8 x for BPA8060 3 pin XLR and 3 pin phoenix electronically balanced 3 dB 40 Hz and 20 kHz gt 90 dBA lt 1 1 kHz 6 dBV to 6 dBV 770mV 22 kOhm Loudspeakers outputs Rated load resistance Rated load capacitance Rated output power per channel Loudspeakers outputs Rated load resistance Rated load capacitance Rated output power per channel Loudspeakers outputs Rated load resistance Rated load capacitance Rated output power per channel Frequency response S N Crosstalk Distortion BPA2120 100 ohm 100 V 50 ohm 70 V 6
4. Public Address Voice Alarm ATEIS DPAfour Digital Power Amplifiers DELIVERING YoOuR MESSAGE DPA four DIGITAL POWER AMPLIFIERS MAIN CHARACTERISTICS 4 audio outputs 100 70 50 V 4 Ohm selectable Fault reporting outputs Four audio inputs with gain Advanced audio processing for each amplifier channel using DIVAS or IDA8 systems Supervision of the amplifiers through DIVA8 or IDA8 systems Back up amplifier switching throught DIVAS or IDA8 sys tems Loudspeaker line and loudspeaker impedance surveil lance through DIVAS or IDA8 systems Output bridging for higher power CONTROLS AND INDICATORS LED VU metering Status indicators for Signal Clip Mains Battery Channel fault and General fault INTERCONNECTIONS Rear Rotary volume control Mains switch Mains input Battery backup input Four line inputs 100 V 70 V 50 V or 4 ohm outputs for each amplifier channel REGION CERTIFICATIONS Europe CE CE 0359 Intertek Immunity according to EN50103 4 PAVA EN54 16 certified 2012 The DPAfour is a 2U 19 rack mountable 4 channel class D power amplifier transformer isolated for 100 V 70 V 50 V and 4 Ohm distributed loudspeaker systems There are two models in the DPAfour range DPAfour125 rated at 4 x 125 W and DPAfour250 at 4 x 250 W Each channel can deliver up to 250 W when used as separate channel or can be bridged to deliver higher power The amplifier has
5. TIONS Rear e Rotary volume control at the rear of the device e Mains switch at the rear of the device e Mains input e Battery backup input e Two line inputs 100 V 70 V and 8 ohm outputs e for each amplifier channel CERTIFICATIONS AND APPROVALS REGION CERTIFICATIONS Europe CE CE 0359 Intertek Immunity according to EN50103 4 PAVA EN54 16 certified 2012 The BPA is a 2U 19 rack mountable 2 channel amplifier transformer isolated for 100 V 70 V and 8 Ohm distributed loudspeaker systems There are three models in the BPA range BPA2120 at 2 x 120 W BPA2240 at 2 x 240 W and BPA2480 at 2 x 480 W The BPA amplifier has a 230V AC mains supply input and a 24 V DC battery back up input which allows it to be used in combination with a battery backup system for maximum availability and reliability in an emergency evacuation system BPA amplifiers have short to ground short circuit detection and line impedance surveillance up to 5 deviation using the DIVA8 or IDA8 systems for loudspeaker line surveillance They support both single spure and redundant loop cabling A B and have a switchover facility that automatically reroutes power to a backup amplifier if present via the SONAES charger in the event of failure BPA amplifiers have a rear panel selector switch for amplifier monitoring according to EN 54 16 DIVAS EA AE AE BE RE AE BEBE BEBE AE AL Ar SY MOE E ee eee E EHEN DEDEIE Fe a ATEIS AG P
6. TS INCLUDED Quantities 1 1 1 1 Components DPA xxxx Digital Power Amplifier Power cord set of connectors Set of feet TECHNICAL SPECIFICATIONS Electrical Mains power supply Voltage Power consumption DPA4125 DPA4250 115 or 230 VAC 15 50 60 Hz standby idle Pmax 1W 38W 600W 1W 44W 1169 W Total Mains power consumption 230 VAC Alarm cycle 10 V pilot Battery power supply Voltage Power consumption DPA4125 DPA4250 tone 24 VDC 19 30 VDC standby idle Imax 0 03A 1 45A 22 5A 0 03 A 1 65 A 43 85 A Total DC current 24 VDC Alarm cycle 10 V pilot Line inputs Connector Frequency response S N THD Input sensitivity Input impedance tone 24 VDC 4 x One per channel 3 pin phoenix 3 dB 50 Hz and 20 kHz gt 90 dB lt 0 1 O 1 kHz 770 mV 20 kOhm DPA four DIGITAL POWER AMPLIFIERS Loudspeakers outputs Rated load resistance Rated load capacitance Rated output power per channel Two channels bridged Loudspeakers outputs Rated load resistance Rated load capacitance Rated output power per channel Two channels bridged Frequency response S N Crosstalk Distortion DPA4125 80 ohm 100 V 62 5 nF 100 V 125 W cont at 40 C 250 W cont at 40 C DPA4250 40 ohm 100 V 120 nF 100 V 250 W cont at 40 C 500 W cont at 40 C 40 Hz to 20 kHz 3 dB gt 90 dB no pilot to
7. a dual voltage mains supply 110 230V AC and a 24 V DC battery back up input which allows it to be used in combination with a battery backup system for maximum availability and reliability in an emergency evacuation system DPAfour amplifiers have short to ground short circuit detection and line impedance surveillance up to 5 deviation using the DIVA8 or IDA8 systems for loudspeaker line surveillance They support both single spure and redundant loop cabling A B The DPAfour amplifiers have a single power supply that shares redundancy via the SONAES battery charger and redundant power supply Using an intelligent switching construction one SONAES can serve up to seven DPAfour amplifiers and three IDA8 units or one DIVA8 with nine slaves In case an internal power supply fails the amplifier modules will automatically switch over to the backup power supply provided by the SONAES leaving the batteries untouched and available for emergency cases DIVA amp DPA Wiring example with DPA Ch 1 amp 2 bridged If DPA channels are f bridged gain settings Se p should be set at E A ji suas a equal level for both channel 1 amp 2 and tet worm or 384 O om 4 pre Brensasseuwawesajsn were me ea rg Baal 9 T o Lt a al il al bed has ls x PORRA dE Ba Poe eee i i Cia That Y pe ere Fe To 7 a ber gt mr zu Cees i IDA8 amp DPA gt Wiring example _ ATEIS A PAR
8. ions Public address systems do not draw a constant current The standard defines a Standby time and an evacuation time In this case it is important to pick a battery back up that can supply the minimum amount of power needed for a set amount of time ATEIS can provide you with a battery calculator program to determine the exact capacity REGULAR PROCEDURE AS FOLLOWS 1 Determine the standby current of the system This information is available in the voice alarm system manual 2 Multiply the standby current by the standby time that the local standards call for Typically this is 24 hours 3 Compare this value to the 24 hour discharge capacity of the battery 4 Determine the evacuation current of the system This information is available in the voice alarm system manual 5 Multiply the evacuation current by the time that the local standards call for Typically this is one hour or 30 minutes 6 Compare this value to the 30 minute or 60 minute hour discharge capacity of the battery ATEIS A do SONAES CHARGER AND MONITORING UNIT EN 54 4 REAR LAYOUT OF SONAES 12 150 TECHNICAL SPECIFICATIONS Electrical Mains power supply Voltage 115 or 230 VAC 15 50 60 Hz Power consumption 380 W at Full load Battery power supply Voltage 24 VDC Maximum charging current Soneas 6 40 6 Amp Soneas 12 150 12 Amp 1 Main power socket Ouputs 2 Auxiliary output terminals Main for amplifiers e Soneas 6 40 2X20A So
9. load e 2 Main outputs max 40 Amp combined load e Battery capacity 85 AH to 225 AH Soneas 12 150 e 2U rack frame charger e 3 Auxilairy outputs max 5 Amp combined load e 6 Main outputs max 20A mp ch e Battery capacity 85 AH to 225 AH CERTIFICATIONS AND APPROVALS REGION CERTIFICATIONS Europe CE CE 0333 AFNOR Immunity according to EN50103 4 PAVA EN54 4 certified 2010 PARTS INCLUDED Quantities 1 1 1 Ordering Information SONEAS 6 40 SONEAS 12 150 Components SONEAS 6 40A or SONEAS 12 150A Power cord Set of connectors The SONEAS series of battery chargers 24 Vdc are intended for a Voice Alarm System The battery chargers are microprocessor based devices that have been designed to charge lead acid batteries back up batteries connected to the Voice Alarm System and simultaneously to provide power to auxiliary devices such as the DIVA8 and IDA8 system controllers The SONEAS battery chargers which are fully compliant with EN54 4 offers a maximum charge current of 6 or 12 A The battery charger is two rack units high and has to be installed in a 19 rack Maximum battery capacity 225 AH OVERVIEW To find the right power back up system for your needs you will need to determine the exact conditions under which you will be utilizing a back up system Determining the amount of battery back up you need for a system is not as simple as some other applicat
10. ne lt 0 dB at nominal load for 1 kHz lt 0 1 1 kHz 100B of rated outputpower Mechanical Dimensions H x W X D Ee 88 5 x 483 x 370 mm Weight DPA 4125 14 kg 31 Ib DPA 4250 18 kg 40 Ib Mounting 19 rackmount Colour RAL7016 Environmental Operating temperature 5 C to 55 C 23 F to 131 F Storage temperature 40 C to 70 C 40 F to 158 F Relative humidity 15 to 90 Air pressure 600 to 1100 h Pa Ordering Informations DPAfour125 Digital Power Amplifier DPAfour250 Digital Power Amplifier 0359 CDP 0177 0359 CDP 0140 12 ATEIS At h AC Power inlet AC DC Fuse Power switch 24 VDC backup Channel 1 4 audio outputs Channel 1 4 audio inputs General fault output contact Service request output contact ES 89 A Lamp test input contact Spare input contact SPA SINEWAVE POWER AMPLIFIERS MAIN CHARACTERISTICS e 2audio outputs 100 70 8 Ohm outputs selectable e Fault reporting outputs e Two audio inputs with gain set Supervision of the amplifiers using DIVA8 or IDA8 controllers Advanced audio processing for each amplifier channel using DIVAS or IDA8 systems Amplifier supervision and spare amplifier switching through DIVAS or IDA8 systems Loudspeaker line and loudspeaker supervision through DIVA8 or IDA8 systems CONTROLS AND INDICATORS LED VU metering Status indicators for Overload Temperature control Batter
11. neas 12 150 6x40A MR 5 Output contacts Auxiallairy ay for controllers 6 Battery terminal Maximum current 5 Amp Temperature sensor 0333 CPD 075382 4 Main output terminals Soneas 6 40 0333 CPD 075381 Soneas 12 150 Batteries 4x 12 VDC 85 to 225AH INSTALLATION NOTES FOR SONAES 6 40 Yuasa NPL series Powersonic GB series Brands ABT TM series Enersys VE series Effekta BTL series Long GB series Mechanical Dimensions H x W X D 19 rack use with brackets ul Weight SONEAS 6 40 4 9 kg 10 8 Ib SONEAS 12 150 6 kg 13 Ib Mounting 19 rackmount Colour RAL7016 Environmental Operating temperature 5 C to 45 C Storage temperature 25 C to 85 C Relative humidity 20 to 95 Air pressure 600 to 1100 h Pa ATEIS A do DELIVERING YoOuR MESSAGE Public Address Voice Alarm ATEIS SEN BPA 7 Sinewave Power Amplifiers Basic Power Amplifiers SONAES i ER Charger and Monitoring Unit Mi ATE S Europe B V Sydneystraat 42 3047 BP ROTTERDAM NETHERLANDS Phone 31 0 10 2088690 Fax 31 0 10 2088699 www ateis europe com info ateis europe com ATEIS reserve the right to change specifications without notice HELPROD COM Product pictures Robert Peek Fotografie Fotolia
12. r Amplifier Power cord Set of mounting brackets for 19 rack set of connectors set of feet TECHNICAL SPECIFICATIONS Electrical Mains power supply Voltage Power consumption SPA 2120 SPA 2240 230 VAC 10 50 60 Hz standby idle Pmax 28 W 150 W 322 W 64 W 287 W 655 W Idle Measured with 10 Volt surveillance tone on the output Total Mains power consumption Battery power supply Voltage Power consumption SPA 2120 SPA 2240 Per ch 28 VDC Alarm cycle 10 V pilot Line inputs Connector electronically balanced Frequency response S N THD Input range Input impedance 21 28 VDC standby idle Imax 0 25A 2 9A 64A 0 30A 5 47 A 12 3A tone 28 VDC 2 x One per channel 3 pin XLR and 3 pin phoenix 3 dB O 40 Hz and 20 kHz gt 90 dBA lt 1 1 kHz 6 dBV to 6 dBV 770mV 22 kOhm SPA2120 100 Ohm 100 V 50 Ohm 70 V 60 nF 100 V 125 nF 70 V Loudspeaker outputs Rated load resistance Rated load capacitance Rated output power per channel 120 W cont at 40 C SPA2240 40 Ohm 100 V 20 Ohm 70 V 125 nF 100 V 250 nF 70 V Loudspeaker outputs Rated load resistance Rated load capacitance Rated output power 240 W cont at 40 per channel Frequency response 40Hz to 20 kHz 3 dB S N gt 90 dB no pilot tone Crosstalk lt 80 dB at nominal load for 1 kHz Distortion lt 1 1 kHz 100B of rated output 12
13. y and Mains INTERCONNECTIONS Rear e Rotary volume control e Mains switch e Mains input e Battery backup input e Two line inputs 100 V 70 V and 8 ohm outputs for each amplifier channel CERTIFICATIONS AND APPROVALS REGION CERTIFICATIONS Europe CE CE 0359 Intertek Immunity according to EN50103 4 PAVA EN54 16 certified 2012 There are two types of power amplifier units in the SPA PAVA product range The overall power rating is 2x120 or 2x240 watts The power amplifiers can be set to 100 V 70 V and 8 Ohm output tappings They have short to ground short circuit detection and line impedance surveillance up to 5 deviation using the DIVA8 and IDA8 range of products for loudspeaker line surveillance They support both single spure and redundant loop cabling A B The amplifiers have a changeover facility for spare power amplifier switching Both features are facilitated by the DIVA8 and IDA8 controllers and slaves The amplifiers have a 24 VDC back up supply input FUNCTIONS The power amplifiers receive line level input signals from the DIVA8 and IDA8 controllers and slaves The display shows the VU meter reading when the EN54 16 default switch is inhibited DIVAS IDA8 8 CH2 ze RE rn Ic B RY FUSE up ok CHI K ENT a co T y Di 1 LJ AC230V 50Hz al ATEIS A le PARTS INCLUDED Quantities 1 1 1 SPA SINEWAVE POWER AMPLIFIERS Components SPA 2xxx Sinewave Powe
Download Pdf Manuals
Related Search
Related Contents
Phone (922)605200 -Fax (922) 修理を依頼される前に takeMS 8GB MEM-P3 Player passion Ultra Protect 5ESL Instructions / Assembly 50 ft x 3/8 in. Capacity Hand Crank Air Hose Reel Manuale di installazione e manutenzione Elettrovalvole con Diffuser Exibir - Service, Support Manual - BikeInn Copyright © All rights reserved.