1. Use either keyboard port per computer To connect the keyboard ports of two CPU Switches use the 5 pin DIN ports only Note 1 Add a power adapter if the CPU Switch works abnormally 2 You cannot use the CPU1 or CPU2 ports of a CS 102 or CS 122 to connect back to a CS 104 or CS 106 You must use the Console ports 3 PS 2 users must connect a PS 2 mouse because a serial mouse can not replace a PS 2 mouse For cascaded operation connect PS 2 mouse ports of successive stages using a 6 pin mini DIN male to male cables 26 2004 08 18 THREE STAGE In a three stage installation the CS 102 or CS 122 is cascaded down from either a CS 104 or CS 106 second stage switch Set DIP switch 4 of the first stage unit On set all others Off Computers may be connected to the first stage the second stage and the third stage CPU Switches 5 pin DIN connectors are for AT style keyboard sockets 6 pin mini DIN connectors are for PS 2 style keyboard sockets Use either keyboard port per computer To connect the keyboard ports of two CPU Switches use the 5 pin DIN ports only Note 1 Add a power adapter if the CPU Switch works abnormally 2 You cannot use the CPU1 or CPU2 ports of a CS 102 or CS 122 to connect back to a CS 104 or CS 106 You must use the Console ports 3 PS 2 users must connect a PS 2 mouse because a serial mouse can not replace a PS 2 mouse For cascaded operation connec
2. Port Connects to a Computer Steady On lw Port Connects to a Computer Flashes Long On Short Off Under Previous Next Mode 5 Port Connects to a Computer Flashes On and Off Equally Under Scan Mode athe 2004 08 18 DIP SWITCH SETTING Scan Time is determined by the DIP Switch of the First Stage CPU Switch For the second and the third stage CS 102 122 units all DIP switches are set to Off DIP Switch Number Scan Time 1 2 3 4 ON ON X ON 3 seconds OFF ON X ON 10 seconds ON OFF X ON 20 seconds OFF OFF X ON 40 seconds The CPU Switch that the keyboard monitor and mouse connect to is the First Stage unit 12 2004 08 18 TROUBLESHOOTING Symptom Cause Action 1st stage Incorrect DIP Switch Set the First Stage unit s DIP Switch 4 CS 102 CS 122 settings to ON for all other cascaded units does not take set DIP Switch 4 to OFF Hot Keys Pressing Hot CS 102 CS 122 is in Press the Spacebar to exit Scan Mode Keys gets no Scan Mode or or Previous Next Mode response Previous Next Mode Selected port Change the port selection to a connects to a powered on computer powered off computer Improper keyboard Unplug the keyboard from the reset connector then plug it back in Improper CS 102 122 Turn off all CS 102s 122s wait for 5 reset seconds then turn them back on Turn off all computers wai
3. Ss VIsvy MSVVIT Srl ATEN 7 SSE So USER MANUAL CS 102 CS 122 Read this guide thoroughly and follow the installation and operation procedures carefully in order to prevent any damage to the unit and or any devices that connect to it This package contains 1 Master View CS 102 or CS 122 KVM Switch 1 User Manual If anything is damaged or missing contact your dealer Copyright 1995 2004 ATEN International Co Ltd Manual Part No PAPE 1249 100 Printed in Taiwan 08 2004 All brand names and trademarks are the registered property of their respective owners 2004 08 18 Note This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the re
4. Dimensions L x W x H CS 102 only CS 122 only 224 x 152 x 52 mm 2004 08 18 INSTALLATION Installation is fast and easy plugging cables into their appropriate ports is all that is entailed A Master View CS 102 CS 122 unit can control two PCs To control even more computers units can be cascaded to three levels CS 102 CS 122 units can also be cascaded down from CS 104 and CS 106 Master View switches SINGLE STAGE A Single Stage Installation enables one CS 102 or CS 122 to control up to two computers as shown in the diagram below P I i Ae 7 t CS amp 102122 CPU SWITCH i z u lli f Set DIP Switch 4 On Connect the monitor output port mouse port and keyboard port of the computer to either of the PC ports on the CPU SWITCH with appropriate cables 5 pin DIN connectors are for AT style keyboard sockets 6 pin mini DIN connectors are for PS 2 style keyboard sockets Use either port per computer Add a power adapter if the CPU Switch works abnormally 2004 08 18 Two STAGE In a two stage installation the CS 102 or CS 122 is cascaded down from either a CS 104 or CS 106 Set DIP Switch 4 of the first stage unit On set all others Off Computers may be connected to the first stage and the second stage CPU Switches 5 pin DIN connectors are for AT style keyboard sockets 6 pin mini DIN connectors are for PS 2 style keyboard sockets
5. ally one by one from the first computer of the first stage to the last computer of the last stage To start Previous Next mode enter this combination Alt Ctr1 Shift 9 Enter To select the previous port press Left Shift To select the next port press Right Shift To end Previous Next Mode press the Spacebar Direct Port Selection With Direct Port Selection you can access any powered on computer on the installation directly To directly select a first stage port enter this combination Alt Ctr1 Shift Enter Where represents the port number that the computer you wish to access is attached to To directly select a second stage port enter this combination Alt Ctrl1 Shiftt Enter Where the first represents the port number on the first stage switch that the second stage switch is connected to and the second represents the port number on the second stage switch that the computer you wish to access is attached to 2004 08 18 To directly select a third stage port enter this combination Alt Ctr1 Shift Enter Where the first represents the port number on the first stage switch that the second stage switch is connected to the second represents the port number on the second stage switch that the third stage switch is connected to and the third represents the port number on the third stage switch that the computer you wish to access is attached to Note
6. ceiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that which the receiver is connected Consult the dealer or an experienced radio television technician for help Fe CE 2004 08 18 OVERVIEW The CS 102 or CS 122 CPU Switch is a controller for one user to access multiple computers Before the development of the Master View the only way to control multiple computer configurations from a single console was through a complex and costly network system Now with a Master View CPU Switch you can easily access multiple computers in a cost effective manner The CS 102 and CS 122 are basically similar in their functions The difference is that the latter offers PS 2 mouse ports There are two methods to switch from one computer to the other with a pushbutton switch or with Hot Keys Setup is fast and easy plugging cables into their appropriate ports is all that is entailed There is no software to configure or install and there are no incompatibility problems Since the Master View intercepts keyboard input directly it works on any hardware platform and with all operating systems A CS 102 CS 122 can control up to two computers Units can be cascaded to three levels allowing the user to control even more computers A powerful auto scan feature scans all operational computers one by one and stops upon user requests Th
7. e CS 102 CS 122 CPU Switch is ideal for Server Control Room Testing etc 2004 08 18 FEATURES CS 102 for PCs CS 122 for PS 2s PS 2 Mouse and MS Mouse Emulation Supports SVGA VGA and Mutisync Monitors Simple Keystrokes or Pushbutton for PC Selection Buzzer Sounds for Switching Confirmation Three Stage Cascadable Power free Operation Auto Scan and Manual Selection Caps Lock Num Lock Scroll Lock States Automatically Saved and Restored When Switching Among Computers Scan Mode Automatically Switches Through Powered On Computers Scan Rate is DIP Switch Selectable Saves Space Equipment and Power Costs Easy Hot Key Control is Compatible With Normal Keyboard Operation 2004 08 18 FRONT REAR AND SIDE VIEWS MASTER VIEW ceu SWITCH CoOPREADY CS 102 Front and Rear Panels Psve 0 emue sru CS 122 Side Panel 2004 08 18 SPECIFICATIONS Function Specification Power Consumption DC 9V 160mA max PC Connections 2 PC Selected By Keyboard Button LEDs 1 Power 2 Ready 2 Select Scan Interval 3 10 20 40 Sec Keyboard Connector 5 pin DIN 6 pin mini DIN Mouse Connector 9 pin D Type Male Female PS 2 Mouse Connector 6 pin mini DIN Female Monitor Connector 15 pin D Type Female Male Enclosure Plastic and Metal Weight 1150g
8. is a digit between 1 and 6 for a CS 106 1 and 4 fora CS 104 and 1 and 2 for a CS 102 CS 122 Hot Key Summary Hot Key functions are summarized in the table below Mode Results For Correct Hot Keys Scan Filters out the Hot Keys and beeps once Scans powered on computers one by one and flashes corresponding LED Scan rate is set by the DIP switch of the 1st stage unit Pressing the Space bar stops this mode Prev Next Filters out the Hot Keys and beeps once Right Shift selects a higher numbered computer Left Shift selects a lower numbered computer Pressing the Space bar stops this mode Direct Filters out the Hot Keys and beeps once for a ready port otherwise beeps twice Switches to the selected port Inputting incorrect hot keys simply displays the keys 10 2004 08 18 APPENDIX LEDS The CS 102 CS 122 contains one Power LED two Ready LEDs and two Port Select LEDs on its front panel Their indications are as follows LED Indication Power LED Lights when the CPU Switch is running Ready LED Lights when the connected PC or CPU Switch is running Port Select LED Lights to indicate the currently selected port Depending on conditions the Port Select LED turns on and off according to the following pattern Condition Pattern 1 Port Not Selected Off 2 Port Connects to a CPU Switch Flashes Long Off Short On
9. t PS 2 mouse ports of successive stages using a 6 pin mini DIN male to male cables ST 2004 08 18 OPERATION There are two ways to access any computer on the installation by pressing the front panel SELECT BUTTON or by entering Hot Keys from the keyboard Once a computer has been accessed the CPU Switch directs keyboard control mouse control and video image of that computer to you as if the computer were right next to you FRONT PANEL BUTTON SELECTION To select a computer with this method Simply press the front panel SELECT BUTTON of the CPU Switch it connects to several times When it is selected the corresponding LED turns on to indicate so Fora two stage installation you have to select with both CPU Switches for a three stage installation you have to select with all three CPU Switches The SELECT LED turns on when the SELECT BUTTON is pressed HoT KEY SELECTION Hot Keys are entered by pressing and releasing the Alt Ctrl and Shift keys simultaneously followed by the command key s and end with pressing the Enter key Scan Mode Scan Mode automatically scans powered on computers one by one from the first computer of the first stage to the last computer of the last stage To start Scan mode enter this combination Alt Ctrl1 Shift 0 Enter To end Scan Mode press the Spacebar 2004 08 18 Previous Next Mode Previous Next Mode selects powered on computers manu
10. t for 5 seconds then turn them back on The The CS 102 122 can Use a DC 9V power adapter with the CS 102 122 not get enough power First Stage unit does not work from the computers properly aT 2004 08 18 LIMITED WARRANTY IN NO EVENT SHALL THE DIRECT VENDOR S LIABILITY EXCEED THE PRICE PAID FOR THE PRODUCT FROM DIRECT INDIRECT SPECIAL INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING FROM THE USE OF THE PRODUCT DISK OR ITS DOCUMENTATION The direct vendor makes no warranty or representation expressed implied or statutory with respect to the contents or use of this documentation and especially disclaims its quality performance merchantability or fitness for any particular purpose The direct vendor also reserves the right to revise or update the device or documentation without obligation to notify any individual or entity of such revisions or update For further inquiries please contact your direct vendor 14 2004 08 18
Download Pdf Manuals
Related Search
Related Contents
HP ProLiant SL2x170z G6 2 Trays 4xL5520 12x2GB Rack Server callas pdfChip Reference Manual (English, pdf). Ariston UPRIGHT FREEZER NO FROST UP 350 FI (FE) User's Manual 第5回定時株主総会 招集ご通知 (PDF: 1832KB) AUG 2002 issue of TOE - Channel Islands PC Users Group BW 350 D - vivanco accesorios s.a.u. AM16/32B Relay Analogue Multiplexer Copyright © All rights reserved.