1. o 4 POST SVUYVrreri USER MANUAL CS 1262 Read this guide thoroughly and follow the installation and operation procedures carefully in order to prevent any damage to the unit and or any devices that connect to it This package contains 1 CS 1262 Two Port DVI Audio KVM Switch 2 Custom KVM Cables Part No 2L 7D02P 1 Power Adapter DC 5 3V 2 4A 1 User Manual 1 Quick Start Guide If anything is damaged or missing contact your dealer O Copyright 2004 2005 ATEN International Co Ltd Manual Part No PAPE 1259 100G Printed in Taiwan 07 2005 All brand names and trademarks are the registered property of their respective owners 2005 07 01 Note This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the inter
2. RESULTING FROM THE USE OF THE PRODUCT DISK OR ITS DOCUMENTATION The direct vendor makes no warranty or representation expressed implied or statutory with respect to the contents or use of this documentation and specially disclaims its quality performance merchantability or fitness for any particular purpose The direct vendor also reserves the right to revise or update the device or documentation without obligation to notify any individual or entity of such revisions or update For further inquires please contact your direct vendor 14 2005 07 01
3. Clock 9 TMDS Datat 24 TMDS Clock 10 TMDS Data1 C1 Analog Red 11 GND C2 Analog Green 12 N C C3 Analog Blue 13 N C C4 Analog H Sync 14 45V Power C5 Analog Ground Analog R G B Return 15 Ground return for 5V H Sync and V Sync 12 2005 07 01 SPECIFICATIONS Function Specification CPU Ports 2 Port Selection Push button switches Hotkeys Console Keyboard 1x6 pin mini DIN F Connectors Mouse 1x6 pin mini DIN F Video 1 x DVI I F Speakers 1 x Earphone jack Microphone 1 x Microphone jack CPU Port Keyboard 2 x 6 pin mini DIN F Connectors Mouse 2 x 6 pin mini DIN F Video 2 x DVI I F Speakers 2 x Earphone jacks Microphone 2 x Microphone jacks LEDs On Line 2 Orange Selected 2 Green Power Consumption DC 5 3V 3 2W max Scan Interval 5 secs default KB Mouse Emulation PS 2 Video Resolution 1600 x 1200 DDC2B PC Compatibility Windows Linux Netware Unix Environment Operating Temperature 0 50 C Storage Temperature 20 60 C Humidity 0 85 RH Noncondensing Housing Metal Weight 0 8kg Dimensions L x W x H 20 0 x 7 45 x 4 2 cm cieo 2005 07 01 LIMITED WARRANTY IN NO EVENT SHALL THE DIRECT VENDOR S LIABILITY EXCEED THE PRICE PAID FOR THE PRODUCT FROM THE DIRECT INDIRECT SPECIAL INCIDENTAL OR CONSEQUENTIAL DAMAGES
4. Each port is color coded and marked with an appropriate icon 2 CPU Port Section The cables that link the switch to your computers plug in here Each CPU section is comprised of a keyboard DVI video mouse microphone and speaker port Each port is color coded and marked with an appropriate icon 3 Power Jack The power adapter cable plugs into this jack 2005 07 01 INSTALLATION 1 Make sure that power to each of the devices you will be connecting up has been turned off You must unplug the power cords of any computers that have the Keyboard Power On function 2 Make sure that all devices you will be connecting up are properly grounded CABLE CONNECTION To set up your Master View CS 1262 installation refer to the installation diagram on the following page the numbers in the diagrams correspond to the steps below and do the following 1 Plug your keyboard DVI monitor mouse microphone and speakers into the Console Ports located on the unit s rear panel 2 Using a KVM cable set provided with this package plug the DVI connector into any available DVI socket in the CPU Port section of the switch and plug the accompanying keyboard mouse microphone and speaker connectors into their corresponding sockets Note 1 Use the end of the cable that has the shorter connector leads the end with the longer leads is for plugging into the computer 2 Be sure that all the plugs are in the same CPU Port s
5. RS The following equipment must be installed on each computer that is to be connected to the system A DVI video port A6 pin mini DIN PS 2 sytle mouse port A6 pin mini DIN PS 2 sytle keyboard port CABLES Only CS Custom cable sets specifically designed to work with this switch may be used to link to the computers For optimum signal integrity and to simplify the layout two high quality cables sets are provided with this package Note There are three types of DVI signals DVI I DVI A DVI D The cable type must match the type of signal being used by the DVI source and the DVI display 2005 07 01 FRONT PANEL master uiew EN EXE cs s 1 Port Selection Switches 2 Port LEDs The Port LEDs are built into the Port Selection Switches The upper ones are the On Line LEDs the lower ones are the Selected Port LEDs An On Line LEDs lights ORANGE to indicate that the computer attached to the corresponding port is up and running A Selected LED lights GREEN to indicate that the computer attached to its corresponding port is the one that has the KVM focus 2005 07 01 REAR PANEL 1 2 OOo SIDA cm 8 o EE a DEEDE o EHEHE S o o cruz i cPU1 i HE 1 Console Port Section The cables from your keyboard monitor mouse microphone and speakers plug in here
6. aning 1 Manual port changes Start of Auto Scan Mode Beeper disabled 2 Power On End of Auto Scan Mode Hotkey port changes Beeper enabled The Beeper can be toggled off and on with the following hotkey combination Scroll Lock Scroll Lock B Enter 8 2005 07 01 PORT SWITCHING There are two convenient methods to switch the KVM and Audio focus between the computers Manual which involves pressing the pushbutton port selection switches located on the unit s front panel and Hotkey which involves entering combinations from the keyboard Manual Press the Port Selection switches as follows Press a switch for longer than two seconds to bring the KVM and audio focus to the computer attached to its corresponding port Press a switch for less than two seconds to bring only the KVM focus to the computer attached to its corresponding port Press switches 1 and 2 simultaneously for 3 seconds to start Auto Scan Mode See p 10 for details Hotkeys Key in the hotkey combinations according to the information in the following table Hotkey Action Scroll Lock Scroll Lock Enter Switches the KVM and audio focus from the port that currently has the KVM focus to the other port 1 to 2 2 to 1 Note that the KVM and audio focus both go to this port even if they were on different ports to begin with Scroll Lock Scroll L
7. ference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that which the receiver is connected Consult the dealer or an experienced radio television technician for help Fe CE 2005 07 01 OVERVIEW The Master View CS 1262 DVI KVM Switch improves on previous KVM Switch designs by incorporating DVI video and audio Now two computers can be accessed and controlled from a single PS 2 keyboard DVI monitor and PS 2 mouse console DVI Digital Visual Interface supports both digital video input flat panel displays data projectors plasma displays digital TVs and set top boxes and analog video input traditional monitors and TVs The CS 1262 is audio enabled A single microphone can provide audio input to each of the computers and you can listen to the audio output of each computer on a single set of speakers on a one at a time basis With the CS 1262 s independent asynchronous switching feature you can even have the KVM focus on one computer while the audio focus is on the other Setup is fast and easy simply plug the cables into their appropriate ports There are no installation routines and no software to configure There are two convenient methods to switch the KVM Audio focus between the computers manually with the push but
8. ock K Enter Brings only the KVM focus from the port that currently has it to the other port The audio focus remains where it is Scroll Lock Scroll Lock S Enter Brings only the audio focus from the port that currently has it to the other port The KVM focus remains where it is 2005 07 01 Auto Scanning The CS 1262 s Auto Scan feature automatically switches the KVM focus between the two computer ports at regular intervals This allows you to monitor the computer activity without having to take the trouble of switching from port to port manually See the table below for details Hotkey Action Scroll Lock Scroll Lock Starts Auto Scan Mode The KVM focus switches A Enter from port to port at 5 second intervals 1 2 3 or 4 Once Auto Scan Mode begins the scan interval can be changed at any time by keying in the number that represents the desired number of seconds as follows 1 3 seconds 2 5 seconds 3 10 seconds 4 20 seconds Esc or Spacebar Exits Auto Scan Mode Note 1 While Auto Scan Mode is in effect ordinary keyboard and mouse functions are suspended only Auto Scan Mode compliant keystrokes and mouse clicks can be input You must exit Auto Scan Mode in order to regain normal control of the console 2 Although the video focus switches from port to port the keyboard mouse and audio do not switch They stay at the port they
9. ockets all in Port 1 all in Port 2 etc 3 The CPU Port sockets and cable plugs are color coded and marked with an appropriate icon for easy installation 3 At the other end of the cable plug the keyboard DVI monitor mouse microphone and speaker connectors into their respective ports on the computer 4 Plug the power adapter that came with your switch into an AC power source then plug power adapter cable into the switch s Power Jack 2005 07 01 00099 5 DF a o m T E CPU 2 2005 07 01 OPERATION HOT PLUGGING The CS 1262 supports hot plugging components can be removed and added back into the installation by unplugging and replugging their cables without the need to shut the unit down POWERING OFF AND RESTARTING If it becomes necessary to Power Off the Master View unit before starting it back up you must do the following 1 Shut down all the computers that are attached to the switch 2 Unplug the switch s power adapter cable 3 Wait 10 seconds then plug the switch s power adapter cable back in 4 After the switch is up Power On the computers THE BEEPER The CS 1262 beeps to provide information about its operations as follows Beeps Me
10. ton port selection switches located on the unit s front panel and with hotkey combinations entered from the keyboard There is no better way to save time and money than with a Master View CS 1262 installation Since a single console manages all of the computers the CS 1262 setup eliminates the expense of having to purchase separate console components for each computer saves all the space those extra components would take up saves on energy costs and eliminates the inconvenience and wasted effort involved in constantly moving from one computer to another 2005 07 01 FEATURES One console controls two computers DVI digital and analog monitor support fully compliant with the DVI specification Audio enabled Easy to install no software required connecting cables to the computers is all it takes Easy to operate manual and hotkey computer selection Auto Scan function to monitor computer operation The KVM and audio focus can be switched together or separately asynchronous switching LED display for easy status monitoring Hot pluggable add or remove computers for maintenance without powering down the switch Keyboard and mouse emulation for error free computer booting Superior video quality up to 1600 x 1200 DDC2B Compatible with all PC compatible operating platforms 2005 07 01 HARDWARE REQUIREMENTS CONSOLE A DVI monitor A PS 2 mouse APS 2 keyboard COMPUTE
11. were on when Auto Scanning started 10 2005 07 01 HOTKEY SUMMARY TABLE Hotkey Action Scroll Lock Scroll Lock Switches the KVM and audio focus from the port Enter that currently has the KVM focus to the other port 1 to 2 2 to 1 Note that the KVM and audio focus both go to this port even if they were on different ports to begin with Scroll Lock Scroll Lock K Brings only the KVM focus from the port that Enter currently has it to the other port The audio focus remains where it is Scroll Lock Scroll Lock S Brings only the audio focus from the port that Enter currently has it to the other port The KVM focus remains where it is Scroll Lock Scroll Lock A Starts Auto Scan Mode The KVM focus switches Enter from port to port at 5 second intervals 1 2 3 or 4 Once Auto Scan Mode begins the scan time interval can be changed at any time by keying in the number that represents desired scan interval Scroll Lock Scroll Lock B Toggles the Beeper on and off Enter ashe 2005 07 01 APPENDIX DVI PIN ASSIGNMENTS Pin Signal Pin Signal 1 TMDS Data2 16 Hot Plug Detect 2 TMDS Data2 17 TMDS Datao 3 GND 18 TMDS Data0 4 NC 19 GND 5 N C 20 N C 6 DDC Clock 21 NC 7 DDC Data 22 TMDS Clock Shield 8 Analog Vertical Sync 23 TMDS