Home
CS-1742 CS-1744
Contents
1. Hotkey Action Scroll Lock Scroll Lock Brings the KVM USB hub and audio focus from the port Enter that currently has the KVM focus to the next port on the installation 1 to 2 2 to 1 for the CS 1742 1 to 2 2 to 3 3 to 4 4 to 1 for the CS 1744 Note The KVM USB hub and audio focus all go to this port even if they were on different ports to begin with Scroll Lock Scroll Lock K Brings only the KVM focus from the port that currently Enter has it to the next port on the installation The USB hub and audio focus remain where they are Scroll Lock Scroll Lock U Brings only the USB hub focus from the port that Enter currently has it to the next port on the installation The KVM and audio focus remain where they are Scroll Lock Scroll Lock S Brings only the audio focus from the port that currently Enter has it to the next port on the installation The KVM and USB hub focus remain where they are 13 CS 1742 CS 1744 User Manual Going Directly to a Port Hotkey Action Scroll Lock Scroll Lock n Brings the KVM USB hub and audio focus to the Enter computer attached to the port corresponding to the specified Port ID Note The KVM USB hub and audio focus all go to this port even if they were on different ports to begin with Scroll Lock Scroll Lock n K Brings only the KVM focus to the computer attached Enter to the specified
2. A VIEW SWIT Gel USER MANUAL CS 1742 CS 1744 CS 1742 CS 1744 User Manual FCC Information This is an FCC Class A product In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense RoHS This product is RoHS compliant FE CE wom CS 1742 CS 1744 User Manual User Notice All information documentation and specifications contained in this manual are subject to change without prior notification by the manufacturer The manufacturer makes no representations or warranties either expressed or implied with respect to the contents hereof and specifically disclaims any warranties as to merchantability or fitness for any particular purpose Any of the manufacturer s software described in thi
3. Hotkey Action Scroll Lock Scroll Lock A Enter Starts Auto Scan The KVM focus cycles from port to port at 5 second intervals Scroll Lock Scroll Lock A n Enter Starts Auto Scan The KVM focus cycles from port to port at n second intervals Note 1 The n stands for the number of seconds that the CS 1742 CS 1744 should dwell on a port before moving on to the next Replace the n with a number between 1 and 99 when entering this hotkey combination 2 While Auto Scan Mode is in effect ordinary keyboard and mouse functions are suspended only Auto Scan Mode compliant keystrokes and mouse clicks can be input You must exit Auto Scan Mode in order to regain normal control of the console To exit Auto Scan Mode press Esc or Spacebar 15 CS 1742 CS 1744 User Manual Hotkey Setting Mode Hotkey Setting Mode is used to set up your CS 1742 CS 1744 switch configuration All operations begin with invoking Hotkey Setting Mode HSM Invoking HSM To invoke HSM do the following 1 Press and hold down the Num Lock key 2 Press and release the minus key 3 Release the Num Lock key Note 1 There is an alternate key combination to invoke HSM See below for details 2 The minus key must be released within one half second otherwise Hotkey invocation is canceled When HSM is active the Caps Lock and Scroll Lock LEDs flash in succession to indicate that HSM is i
4. rug etc as this will block its ventilation openings Likewise the device should not be placed in a built in enclosure unless adequate ventilation has been provided Never spill liquid of any kind on the device Unplug the device from the wall outlet before cleaning Do not use liquid or aerosol cleaners Use a damp cloth for cleaning The device should be operated from the type of power source indicated on the marking label If you are not sure of the type of power available consult your dealer or local power company The device is equipped with a 3 wire grounding type plug This is a safety feature If you are unable to insert the plug into the outlet contact your electrician to replace your obsolete outlet Do not attempt to defeat the purpose of the grounding type plug Always follow your local national wiring codes Do not allow anything to rest on the power cord or cables Route the power cord and cables so that they cannot be stepped on or tripped over If an extension cord is used with this device make sure that the total of the ampere ratings of all products used on this cord does not exceed the extension cord ampere rating Make sure that the total of all products plugged into the wall outlet does not exceed 15 amperes To help protect your system from sudden transient increases and decreases in electrical power use a surge suppressor line conditioner or un interruptible power supply UPS Position system cables and
5. Keyboard Sun Keyboard Ctrl T Stop Ctrl F2 Again Ctrl F3 Props Ctrl F4 Undo Ctrl F5 Front Ctrl F6 Copy Ctrl F7 Open Ctrl F8 Paste Ctrl F9 Find Ctrl F10 Cut Ctrl 1 m Ctrl 2 O S m Ctrl 3 O 0 Ctrl 4 C Ctrl H Help p Compose BE Note When using key combinations press and release the first key Ctrl then press and release the activation key 22 Chapter 6 The Firmware Upgrade Utility The Windows based Firmware Upgrade Utility FWUpgrade exe provides a smooth automated process for upgrading the KVM switch s firmware The Utility comes as part of a Firmware Upgrade Package that is specific for each device New firmware upgrade packages are posted on our web site as new firmware revisions become available Check the web site regularly to find the latest packages and information relating to them http www aten com tw Preparation 1 From a computer that is not part of your KVM installation go to our Internet support site and choose the model name that relates to your device CS 1742 or CS 1744 to get a list of available Firmware Upgrade Packages 2 Choose the Firmware Upgrade Package you want to install usually the most recent and download it to your computer 3 Use the Firmware Upgrade Cable provided with this unit to connect a COM port on your computer to the Firmware Upgrade Port of your switch 4 Invoke Firmware Upgrade Mode see p
6. User Manual Quick Start Guide Apa Check to make sure that all the components are present and that nothing got damaged in shipping If you encounter a problem contact your dealer Read this manual thoroughly and follow the installation and operation procedures carefully to prevent any damage to the unit and or any of the devices connected to it Features may have been added to this product since the manual was written Visit our website to download the latest version of this manual Copyright 2006 ATEN International Co Ltd Manual Part No PAPE XXXX XXXX Printing Date 05 2006 ATEN and the ATEN logo are registered trademarks of ATEN International Co Ltd All rights reserved All other brand names and trademarks are the registered property of their respective owners vii CS 1742 CS 1744 User Manual This Page Intentionally Left Blank viii CS 1742 CS 1744 User Manual Contents EGG Information sau sanada ESSE aaa ii WISER NOTICE rsss ii ta doo i aree kates ili Safety Instructions LL iv Generali io ee unta pa Roio iv Rack Mounting 0 vi Package Contents vii About this Manual 2 0 2 0 0 eee xi CONVENTIONS y sisi al a xii Getting Help x civic pad ead a eee ay xii 1 Introduction OVEIVICW sn eS cileni DE hte Soa pao letali debile eek ad lt 1 Features alii ie O E acai 2 Requirements sen ag a a a Sid papi a 3 A pere Sa 3 Computer s e aan La RA L
7. especially disclaims its quality performance merchantability or fitness for any particular purpose The direct vendor also reserves the right to revise or update the device or documentation without obligation to notify any individual or entity of such revisions or update For further inquiries please contact your direct vendor 31 CS 1742 CS 1744 User Manual This Page Intentionally Left Blank 32 Index A HSM Alternate HSM Keys 17 alternate keys 17 invoking 16 Alt itching K 17 ernate Switching Keys Summary Table 20 Auto Scanning 15 C Invoking HSM 16 Cable Connection 9 Components K Front View 4 Keyboard emulation Rear View 6 Mac 21 Sun 22 D Keyboard Operating Platform 18 Disable Port Switching Keys 19 L Limited Warranty 31 List Hotkey Settings 18 F FCC Information ii Firmware Upgrade Failed 28 M Interrupted 28 Mac keyboard emulation 21 Preparation 23 Manual conventions xii Starting 24 Succeeded 27 Manual port switching 11 Firmware Upgrade Mode 19 p G Package Contents vii Getting Help xii Port ID Numbering 12 Port switching H alternate keys 17 Hardware Setup 9 cycling 13 Hot Plugging 11 direct 14 disable keys 19 Hotkey hotkey 13 Beeper Control 19 manual 11 Default Settings 31 Setting Mode 16 Powering Off and Restarting 12 33 CS 1742 CS 1744 User Manual R Sun keyboard emulation 22 Rack Mounting System Req
8. from the USB port on the switch s rear panel then plug it back in Use the USB Reset hotkey combination see page 19 to reset the USB ports Device not Windows timing 1 Unplug the KVM cable from the computer s recognized problem USB port Wig 2 Go into Windows System Settings and remove Windows the Unknown Device entry 3 Plug the KVM cable back in Windows will now recognize the device Sun system CPU port not The first time that a Sun system runs from a port does not start configured correctly you must configure its port for the Sun keyboard operating platform before you turn the system on or else the Sun system will not start See page 18 for details 30 Appendix Hotkey Default Settings The hotkey factory default settings are given in the table below Setting Default Port Switching Scroll Lock Scroll Lock Invoking HSM Num Lock Auto Scan Interval 5 seconds Beeper On Keyboard Operating Platform PC Compatible Auto Detect Port Switching Keys Enabled Limited Warranty IN NO EVENT SHALL THE DIRECT VENDOR S LIABILITY EXCEED THE PRICE PAID FOR THE PRODUCT FROM DIRECT INDIRECT SPECIAL INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING FROM THE USE OF THE PRODUCT DISK OR ITS DOCUMENTATION The direct vendor makes no warranty or representation expressed implied or statutory with respect to the contents or use of this documentation and
9. M see page 16 2 Press and release the B key The Beeper toggles On or Off The Command Line displays Beeper On or Beeper Off for one second then the message disappears and you automatically exit Hotkey Mode Disable Port Switching Keys To disable the Port Switching Keys Scroll Lock Scroll Lock Ctrl Ctrl do the following 1 Invoke HSM see page 16 2 Press X Enter This procedure is a toggle To enable the Port Switching keys repeat steps 1 and 2 Firmware Upgrade Mode To set the CS 1742 CS 1744 to Firmware Upgrade Mode do the following 1 Invoke HSM see page 16 2 Key in upgrade 3 Press Enter The front panel LEDs flash to indicate Firmware Upgrade Mode is in effect Note To exit Firmware Upgrade Mode you must power off the switch CS 1742 CS 1744 User Manual Restore Default Settings To reset the CS 1742 CS 1744 to its default hotkey settings do the following 1 Invoke HSM see page 16 2 Press R Enter All hotkey settings return to the factory default settings A table showing the CS 1742 CS 1744 s default settings is provided in the appendix on page 31 HSM Summary Table After invoking HSM see page 16 key in one of the following keys to perform the corresponding function Key In Action H Toggles between the default and alternate HSM invocation keys T Toggles between the default and alternate Port Switchi
10. Searching for devi 25 CS 1742 CS 1744 User Manual 5 After you have made your device selection s Click Next to perform the upgrade If you enabled Check Firmware Version the Utility compares the device s firmware level with that of the upgrade files If it finds that the device s version is higher than the upgrade version it brings up a dialog box informing you of the situation and gives you the option to Continue or Cancel Prompt gt The firmware Ver 1 0 is not newer than current firmware Ver 1 0 090 2 in device CS 1742 1744 MAIN 000 Continue the upgrade Yes No _s If you didn t enable Check Firmware Version the Utility installs the upgrade files without checking whether they are a higher level or not As the Upgrade proceeds status messages appear in the Status Messages panel and the progress toward completion is shown on the Progress bar 26 6 The Firmware Upgrade Utility Upgrade Succeeded After the upgrade has completed a screen appears to inform you that the procedure was successful Firmware Upgrade Utility gt Loading amp testing files gt Loading amp testing files OK gt Searching for devices gt Preparing firmware upgrade gt Firmware version is not newer than device CS 1734 1732 MAIN 000 gt Preparing firmware upgrade OK gt Upgrading device C5 1734 1732 MAN w To complete the upgrade l 2 Cl
11. age 19 The front panel LEDs flash together to indicate Firmware Upgrade Mode is in effect z gt MAN ES SST a fo lo E fo MU LOCO Bei DO JH do Seo Do 4 ju E qa OB CPR 23 CS 1742 CS 1744 User Manual Starting the Upgrade To upgrade your firmware 1 Run the downloaded Firmware Upgrade Package file either by double clicking the file icon or by opening a command line and entering the full path to it The Firmware Upgrade Utility Welcome screen appears Firmware Upgrade Utility Note The screenshots in this section are for example purposes The screens that appear during your firmware upgrade may vary as to their wording and descriptions 24 6 The Firmware Upgrade Utility 2 Read and Agree to the License Agreement enable the J Agree radio button 3 Click Next to continue The Firmware Upgrade Utility main screen appears 25 Firmware Upgrade Utility The Utility inspects your installation All the devices capable of being upgraded by the package are listed in the Device List panel 4 As you select a device in the list its description appears in the Device Description panel 25 Firmware Upgrade Utility gt Loading amp testing files gt Loading amp testing files OK
12. ding port is the one that has the KVM focus Selected Flashes to indicate that the computer attached to its corresponding port is being accessed under Auto Scan mode USB Lights DIM GREEN to indicate that there is a USB cable connection to the computer Does not light if there is no USB connection to the computer see item 2 of the installation diagram on page 10 Changes to BRIGHT GREEN to indicate that the computer attached to its corresponding port is the one that has access to the USB peripherals USB Port Cables from your USB peripherals printers scanners etc can plug in here as well as into the USB port on the rear panel CS 1742 CS 1744 User Manual Rear View CS 1742 CS 1744 4 A e a 1 Introduction The rear panel components are described in the table below No Component Description 1 Power Jack If you choose to use external power the power adapter cable plugs into this jack Note Use of a power adapter DC 5V is optional and requires a separate purchase See the note on page 10 for power adapter details 2 Firmware The Firmware Upgrade Cable that transfers the firmware Upgrade Port upgrade data from the administrator s computer to the CS 1742 CS 1744 plugs into this RJ 11 connector See Chapter 6 for firmware upgrading details 3 Console Port The cables from your console components keyb
13. e O La 3 Gables to Deal De E o Bo TE Ev 3 OS Sci a SR na a ia a ohne oa a 3 Components tl dir dn pad SUE E pad e da rea ita 4 Front VIEW Essa nen ele a a kee ae aaa ii 4 GSA OE ha exe cote A Bas DESDE and atte ae A 4 CSV TAA ee A css ar cs eid Atay 4 Rear VIEW snnt afraid 6 CSATA denti Ania ere e ie 6 GS ITA ee pi a FM e a oa 6 2 Hardware Setup Gable Connections cirie Saks Bhs eat 9 3 Basic Operation Manual Switching 0 0 11 Hot Pluggingi site los Beek Wa eel done Be a aa 11 Powering Off and Restarting 00 0 cece e eee eee 12 Port ID Numbering 02 0 c eee eee 12 4 Hotkey Operation Port Switching osor eir ecw eens ode ya dee See en 13 Cycling Through the Ports 13 Going Directly to a Port 14 Auto Scafinifigi 1 gt sir aaa 15 Hotkey Setting Mode 0 0 cee cette ee 16 INVOKIN ASM ccoo ie rire ue 16 Alternate HSM Invocation Keys Li 17 CS 1742 CS 1744 User Manual Alternate Port Switching KeysS 000 e eee eee eee eee 17 Keyboard Operating Platform 18 List Hotkey Settings 0 0 cee eee eee 18 USB Reset ir Sr adits Ava pce apd e aaa 19 Hotkey Beeper Control 19 Disable Port Switching Keys 19 Firmware Upgrade Mode cee eee eee eee 19 Restore Default Settings 20 HSM Summary Table LL 20 5 Keyboard Emulation Mac Keyboard ss mus ema bbe i e o aa 21 SUN Keyboard uri rancia daa ea ES dg Rete SOR gee earn 22 6 The Firmwar
14. e Upgrade Utility Preparation A REL 23 Starting the Upgrade 1 0 0 0 eect tee 24 Upgrade Succeeded 0 cece ete ee 27 Upgrade Falled iii pi puma do eke ees 28 Upgrade Interrupted cece eee 28 Appendix Specifications sa sis asas ea ee ee ees 29 Troubleshooting i impari Seba Reeds ee 30 Hotkey Default Settings 31 Limited Warranty sas suar nia gia E a pa n 31 Index CS 1742 CS 1744 User Manual About this Manual This User Manual is provided to help you get the most from your c c system It covers all aspects of installation configuration and operation An overview of the information found in the manual is provided below Chapter 1 Introduction introduces you to the CS 1742 CS 1744 system Its purpose features and benefits are presented and its front and back panel components are described Chapter 2 Hardware Setup describes how to set up your installation The necessary steps from a basic single stage hookup to a complete 32 switch daisy chained operation are provided Chapter 3 Basic Operation explains the fundamental concepts involved in operating the CS 1742 CS 1744 Chapter 4 Hotkey Operation details all of the concepts and procedures involved in the Hotkey operation of your CS 1742 CS 1744 installation Chapter 5 Keyboard Emulation provides tables that list the PC to Mac and PC to Sun keyboard emulation mappings Chapter 6 The Firmware Upgrade Utility
15. en USB Peripheral Ports 2 x USB Type A female Firmware Upgrade Port Power Jack 1 x RJ 11socket 1x DC 5V Scan Interval 1 99 secs 5 secs default KB Mouse Emulation USB PC Mac Sun Resolution Up to 2048 x 1536 DDC2B Power Consumption DC5V 1 25W DC5V 1 35W Power Adapter optional 1x DC 5V 2 6A Environment Operating Temp 0 50 C Storage Temp 20 60 C Humidity 0 80 RH Physical Housing Metal Properties Weight 0 82 kg 1 03 kg LxWxH 20 x 7 45 x 4 3 cm 26 x 7 45 x 4 2 29 CS 1742 CS 1744 User Manual Troubleshooting Erratic Unit not Use a DC 5V power adapter if you are not already behavior receiving using one If you are already using a power adapter enough power check that it matches the system specifications DC 5V and that it is plugged in and functioning properly Keyboard and or Mouse not responding USB devices not responding Keyboard and or mouse need to be reset Unplug the cable s from the console port s then plug it them back in No connection to the computer Check the cable from the switch to the computer to make sure it is properly connected KVM switch needs to be reset USB ports need to be reset Power off all devices on the installation see the note at the top of page 9 power off the KVM switch wait five seconds then power up Unplug the device s USB cable
16. ess and release the T key again CS 1742 CS 1744 User Manual Keyboard Operating Platform The CS 1742 CS 1744 s default port configuration is for a PC Compatible keyboard operating platform If you have a Mac or Sun attached to a port you can change the port s keyboard operating platform configuration as follows 1 Bring the KVM focus to the port you want to set 2 Invoke HSM see page 16 3 Press and release the appropriate Function key see table After completing a setting you automatically exit HSM Function Key Action F2 Sets the Mac keyboard operating platform F3 Sets the Sun keyboard operating platform F10 Auto detects the keyboard operating platform for PC compatible systems The first time that the Sun system runs from a port you must configure its port for the Sun keyboard operating platform before you turn the system on or else the Sun system will not start List Hotkey Settings To see a listing of the current hotkey settings do the following 1 Open a text editor or word processor 2 Invoke HSM see page 16 3 Press and release the F4 function key 4 Hotkey Operation USB Reset If the USB loses focus and needs to be reset do the following 1 Invoke HSM see page 16 2 Press and release the F5 function key Hotkey Beeper Control The Beeper can be hotkey toggled On and Off To toggle the Beeper do the following 1 Invoke HS
17. explains how to use this utility to upgrade the CS 1742 CS 1744 s firmware with the latest available versions An Appendix provides specifications and other technical information regarding the CS 1742 CS 1744 xi CS 1742 CS 1744 User Manual Conventions This manual uses the following conventions Monospaced Indicates text that you should key in Indicates keys you should press For example Enter means to press the Enter key If keys need to be chorded they appear together in the same bracket with a plus sign between them Ctrl Alt ils Numbered lists represent procedures with sequential steps Bullet lists provide information but do not involve sequential steps gt Indicates selecting the option on a menu or dialog box for example that comes next For example Start Run means to open the Start menu and then select Run Indicates critical information Getting Help If you need to contact ATEN technical support with a problem visit or website at www aten com xii Chapter 1 Introduction Overview The Master View Dual View CS 1742 or CS 1744 USB KVM Switch brings dual head video functionality to ATEN s USB KVM switch technology Now two CS 1742 or four CS 1744 dual head computers can be accessed and controlled from a single console that consists of a USB keyboard USB mouse and two VGA SVGA or Multisync monitors In addition the CS 1742 CS 1744 incorporates a two por
18. he Ports 13 Going Directly to a Port 14 Auto Scafinifigi 1 sr nai ea 15 Hotkey Setting Mode 16 Invoking HSM cra ie lr ie ai ea 16 Alternate HSM Invocation Keys 17 CS 1742 CS 1744 User Manual Alternate Port Switching KeysS 000 e eee eee eee eee 17 Keyboard Operating Platform 18 List Hotkey Settings 0 0 cee eee eee 18 USB Reset ir Sr adits Ava pce apd e aaa 19 Hotkey Beeper Control 19 Disable Port Switching Keys 19 Firmware Upgrade Mode cee eee eee eee 19 Restore Default Settings 20 HSM Summary Table LL 20 5 Keyboard Emulation Mac Keyboard ss mus ema bbe i e o aa 21 SUN Keyboard uri rancia daa ea ES dg Rete SOR gee earn 22 6 The Firmware Upgrade Utility Preparation A REL 23 Starting the Upgrade 1 0 0 0 eect tee 24 Upgrade Succeeded 0 cece ete ee 27 Upgrade Falled iii pi puma do eke ees 28 Upgrade Interrupted cece eee 28 Appendix Specifications sa sis asas ea ee ee ees 29 Troubleshooting i impari Seba Reeds ee 30 Hotkey Default Settings 31 Limited Warranty sas suar nia gia E a pa n 31 Index
19. ick Finish to close the Firmware Upgrade Utility Power off the switch Unplug the KVM cables from the back of the switch If you are using a power adapter with your switch unplug its power adapter cable from the power jack Remove the Firmware Upgrade Cable Connect all the KVM cables If you are using a power adapter plug its cable back in 27 CS 1742 CS 1744 User Manual Upgrade Failed If the Upgrade Succeeded screen doesn t appear it means that the upgrade failed to complete successfully in which case you should repeat the upgrade procedure from the beginning Upgrade Interrupted If the firmware upgrade procedure is abnormally halted due to computer crash power failure etc the switch may become inoperable If you find that the switch does not work following an interrupted upgrade you must return it to the factory to have the firmware reinstalled Contact your dealer for details 28 Appendix Specifications Function CS 1742 CS 1744 Computer Connections 2 4 KVM CPU Port Selection Front Panel Switches Hotkey Console Keyboard 1 x USB Type A female Connectors Mouse 1 x USB Type A female Video 2 x HDB 15 female Audio 1 x Mini stereo jack 1 x Microphone jack Computer Connectors 2 x SPHD 15 female 2 x SPHD 15 male 4 x SPHD 15 female 4 x SPHD 15 male LEDs On Line Selected 2 Orange 4 Orange USB Link 2 Green 4 Gre
20. ied technician to repair CS 1742 CS 1744 User Manual Rack Mounting Before working on the rack make sure that the stabilizers are secured to the rack extended to the floor and that the full weight of the rack rests on the floor Install front and side stabilizers on a single rack or front stabilizers for joined multiple racks before working on the rack Always load the rack from the bottom up and load the heaviest item in the rack first Make sure that the rack is level and stable before extending a device from the rack Use caution when pressing the device rail release latches and sliding a device into or out of a rack the slide rails can pinch your fingers After a device is inserted into the rack carefully extend the rail into a locking position and then slide the device into the rack Do not overload the AC supply branch circuit that provides power to the rack The total rack load should not exceed 80 percent of the branch circuit rating Ensure that proper airflow is provided to devices in the rack Do not step on or stand on any device when servicing other devices in a rack vi CS 1742 CS 1744 User Manual Package Contents The complete CS 1742 CS 1744 package consists of CS 1742 or CS 1744 USB KVM Switch Custom Audio Video Cable Sets CS 1742 Custom USB Video Cable Sets CS 1742 Custom Audio Video Cable Sets CS 1744 Custom USB Video Cable Sets CS 1744 Firmware Upgrade Cable
21. moving from one computer to another CS 1742 CS 1744 User Manual Features Provides a second video channel to support dual head computers One console controls 2 CS 1742 or 4 CS 1744 dual head computers Two USB ports for USB device sharing Audio jacks for speaker and microphone sharing Independent asynchronous switching of the KVM USB and audio focus Fully compliant with the USB 1 1 specification supports transfer rates of 1 5 12 Mbps Easy to install no software required connecting cables is all it takes Easy to operate computer selection via push button switches or hotkeys Hotkey OS selection LED display for easy status monitoring Auto Scan Mode for monitoring all computers Caps Lock Num Lock and Scroll Lock states are saved and restored when switching Keyboard and mouse emulation for error free booting Supports multimedia USB keyboards supports Mac amp Sun keyboards Supports Microsoft Intellimouse and the scrolling wheel on most mice supports Logitech and Microsoft wireless keyboards and mice Supports multibutton mice with appropriate drivers installed Superior video quality 2048 x 1536 DDC2B Hot pluggable add or remove computers for maintenance without powering down the switch Upgradeable firmware Compatible with major operating platforms 1 Introduction Requirements Console Monitors capable of the highest resolution that y
22. n effect They stop flashing and revert to normal status when you exit HSM Ordinary keyboard and mouse functions are suspended only Hotkey compliant keystrokes and mouse clicks described in the sections that follow can be input At the conclusion of some hotkey operations you automatically exit hotkey mode With some operations you must exit manually To exit HSM manually press Esc or the Spacebar 4 Hotkey Operation Alternate HSM Invocation Keys An alternate set of HSM invocation keys is provided in case the default set conflicts with programs running on the computers To switch to the alternate HSM invocation set do the following 1 Invoke HSM see page 16 gt 2 Press and release the H key The HSM invocation keys become the Ctrl key instead of Num Lock and the F12 key instead of minus Note This procedure is a toggle between the two methods To revert back to the original HSM invocation keys invoke HSM then press and release the H key again Alternate Port Switching Keys The port switching activation keys can be changed from tapping the Scroll Lock key twice Scroll Lock Scroll Lock to tapping the Ctrl key twice To change the port switching activation keys do the following 1 Invoke HSM see page 16 2 Press and release the T key Note This procedure is a toggle between the two methods To revert back to the original Scroll Lock Scroll Lock method invoke HSM then pr
23. nd do the following 1 Plug your Console devices USB keyboard USB mouse monitors microphone and speakers into the switch s Console Ports Use the Port A KVM cable the one with the USB connector to connect any available CPU A port to the first VGA port and the USB port of the computer you are installing Use the Port B KVM cable the one with the microphone and speaker connectors to connect the CPU B port to the second VGA port and the audio jacks of the computer you are installing Note Be sure that the Port B cable is in the same CPU port as the Port A cable both in Port 1 both in Port 2 etc Connect your USB peripherals to the USB ports located on the front and rear panels lt Manual gt User Manual 5 If you choose to use external power plug the power adapter cable into the switch s Power Jack then plug the power adapter into an AC power source Note The power adapter should be DCSV 2 6A with e the inside positive and the outside negative 6 Turn on the power to the computers z gt AZ Wed BE O uz gt HE BBE EER om a E al Chapter 3 Basic Operation Manual Switching There are two convenient methods to access the computers Manual which involves pressi
24. ng keys F2 Sets the Mac keyboard operating platform F3 Sets the Sun keyboard operating platform F10 Auto detects the keyboard operating platform for PC compatible systems F4 Lists the current hotkey settings via the Paste function of a text editor or WP F5 Performs a USB reset B Toggles the beeper On and Off X Enter Enables Disables the Port Switching keys R Ente Resets the hotkey settings to their default status upgrade Enter Invokes Firmware Upgrade Mode 20 Mac Keyboard Chapter 5 Keyboard Emulation The PC compatible 101 104 key keyboard can emulate the functions of the Mac keyboard The emulation mappings are listed in the table below PC Keyboard Mac Keyboard Shift Shift Ctrl Ctrl Em Ctrl 1 d Ctrl 2 mq Ctrl 3 mq Ctrl 4 A Alt Alt Print Screen F13 Scroll Lock F14 E Enter Return Backspace Delete Insert Help Ctrl ER F15 Note When using key combinations press and release the first key Ctrl then press and release the activation key 21 CS 1742 CS 1744 User Manual Sun Keyboard The PC compatible 101 104 key keyboard can emulate the functions of the Sun keyboard when the Control key Ctrl is used in conjunction with other keys The corresponding functions are shown in the table below PC
25. ng the pushbutton port selection switches located on the unit s front panel and Hotkey which involves entering combinations from the keyboard Hotkey port selection is discussed in the next chapter For manual port selection Press and release a port selection switch to bring the KVM focus to the computer attached to its corresponding port The USB and Audio focus does not change they stay with the port that they are already on Press and hold a port selection switch for more than 2 seconds to bring the KVM focus plus the USB and Audio focus to the computer attached to its corresponding port Press and hold port selection switches 1 and 2 for more than 2 seconds to start Auto Scan Mode see page 15 for Auto Scan Mode details Press and release either port selection switch to stop Auto Scan Mode The KVM focus goes to the computer attached to the corresponding port of the switch you pressed Hot Plugging The Master View CS 1742 CS 1744 supports USB hot plugging Components can be removed and added back into the installation by unplugging their cables from the USB hub ports without the need to shut the unit down CS 1742 CS 1744 User Manual Powering Off and Restarting If it becomes necessary to Power Off the Master View unit do the following 1 Disconnect all the KVM cables from the CPU Port section of the switch refer back to the installation diagram on page 10 2 If you are using an external powe
26. oard Section mouse monitors speakers and microphone plug in here Each port is marked with an icon to indicate itself 4 KVM CPU Port The cables that link the switch to your computers plug in Section here Each port is comprised of two connectors The upper connector carries the audio data microphone and speakers and the video data for monitor B the lower connector carries the USB data keyboard mouse and peripherals and the video data for monitor A 5 USB Port Cables from your USB peripherals printers scanners etc can plug in here as well as into the USB port on the front panel Only cables specifically designed to work with this switch can be used see the Cables section on page 3 for details Do NOT attempt to use ordinary 15 pin VGA connector cables to link these ports to the computers CS 1742 CS 1744 User Manual This Page Intentionally Left Blank Chapter 2 Hardware Setup device is provided on page iv Please review it before l 1 Important safety information regarding the placement of this proceeding 2 Make sure that power to all the devices you will be connecting up have been turned off You must unplug the power cords of any computers that have the Keyboard Power On function Cable Connection To set up your Master View CS 1742 CS 1744 installation refer to the installation diagram on the next page the numbers in the diagram correspond to the steps below a
27. ou will be using on any computer in the installation A USB style mouse A USB style keyboard Computer A VGA SVGA or Multisyne port Type AUSB port Cables Only Custom cable sets specifically designed to work with this switch may be used to link to the computers Two CS 1742 or four CS 1744 cable sets are provided with this package Additional cable sets can be purchased from your dealer os Windows 98SE or higher Mac OS 8 6 or higher SUN Blade 2000 100 Sun Solaris 8 or higher Unix Linux RedHat 7 1 or higher CS 1742 CS 1744 User Manual Components Front View CS 1742 Dual vGA a J 8 Cc 1 amp 2 3 CS 1744 even oe za o ase Jo O 1 amp 2 3 1 Introduction The front panel components are described in the table below No Component Description Port Selection Switches Press a switch to access the computer attached to its corresponding port Pressing Buttons 1 and 2 simultaneously for 2 seconds starts Auto Scan Mode See page 15 for details Port LEDs The Port LEDs are built into the Port Selection Switches The upper ones are the KVM Port LEDs the lower ones are the USB LEDs KVM Lights DIM ORANGE to indicate that the computer attached to the corresponding port is up and running On Line Changes to BRIGHT ORANGE to indicate that the computer attached to its correspon
28. port The USB hub and audio focus remain where they are Scroll Lock Scroll Lock n U Brings only the USB hub focus to the computer Enter attached to the specified port The KVM and audio focus remain where they are Scroll Lock Scroll Lock n S Brings only the audio focus to the computer attached Enter to the specified port The KVM and USB hub focus remain where they are Scroll Lock Scroll Lock n K Brings the KVM and USB hub focus to the computer U Enter attached to the specified port The audio focus remains where it is Scroll Lock Scroll Lock n K Brings the KVM and audio focus to the computer S Enter attached to the specified port The USB hub focus remains where it is Scroll Lock Scroll Lock n U Brings the USB hub and audio focus to the computer S Enter attached to the specified port The KVM focus remains where it is Note The n stands for the computer s Port ID number 1 2 3 or 4 see Port ID Numbering page 12 Replace the n with the appropriate Port ID when entering hotkey combinations 14 4 Hotkey Operation Auto Scanning The CS 1742 CS 1744 s Auto Scan feature automatically cycles the KVM focus through the computer ports at regular intervals This allows you to monitor the computer activity without having to take the trouble of switching from port to port manually See the table below for details
29. power cables carefully Be sure that nothing rests on any cables CS 1742 CS 1744 User Manual When connecting or disconnecting power to hot pluggable power supplies observe the following guidelines Install the power supply before connecting the power cable to the power supply Unplug the power cable before removing the power supply Ifthe system has multiple sources of power disconnect power from the system by unplugging all power cables from the power supplies Never push objects of any kind into or through cabinet slots They may touch dangerous voltage points or short out parts resulting in a risk of fire or electrical shock Do not attempt to service the device yourself Refer all servicing to qualified service personnel If the following conditions occur unplug the device from the wall outlet and bring it to qualified service personnel for repair The power cord or plug has become damaged or frayed Liquid has been spilled into the device The device has been exposed to rain or water The device has been dropped or the cabinet has been damaged The device exhibits a distinct change in performance indicating a need for service The device does not operate normally when the operating instructions are followed Only adjust those controls that are covered in the operating instructions Improper adjustment of other controls may result in damage that will require extensive work by a qualif
30. r adapter unplug the switch s power adapter cable 3 Wait 10 seconds then reconnect the KVM cables 4 If you are using an external power adapter plug the switch s power adapter cable back in Port ID Numbering Each CPU port on the CS 1742 CS 1744 switch is assigned a port number 1 or 2 for the CS 1742 1 to 4 for the CS 1744 The port numbers are marked on the rear panel of the switch see page 6 The Port ID of a computer is derived from the CPU port number it is connected to For example a computer connected to CPU port 2 has a Port ID of 2 The Port ID is used to specify which computer gets the KVM USB peripheral and audio focus with the Hotkey port selection method see Going Directly to a Port page 14 for details Chapter 4 Hotkey Operation The CS 1742 CS 1744 hotkey function makes it convenient to operate your KVM installation from the keyboard Asynchronous independent switching of the KVM USB hub and audio focus is supported You can give one computer the KVM console focus another the USB hub focus while a third has the audio focus Port Switching All port switches begin with tapping the Scroll Lock key twice The tables below describe the actions that each combination performs Note If using the Scroll Lock key conflicts with other programs running on the computer the Ctrl key can be used instead See Alternate HSM Invocation Keys page 17 for details Cycling Through the Ports
31. s manual is sold or licensed as is Should the programs prove defective following their purchase the buyer and not the manufacturer its distributor or its dealer assumes the entire cost of all necessary servicing repair and any incidental or consequential damages resulting from any defect in the software The manufacturer of this system is not responsible for any radio and or TV interference caused by unauthorized modifications to this device It is the responsibility of the user to correct such interference The manufacturer is not responsible for any damage incurred in the operation of this system if the correct operational voltage setting was not selected prior to operation PLEASE VERIFY THAT THE VOLTAGE SETTING IS CORRECT BEFORE USE CS 1742 CS 1744 User Manual Safety Instructions General Read all of these instructions Save them for future reference Follow all warnings and instructions marked on the device Do not place the device on any unstable surface cart stand table etc If the device falls serious damage will result Do not use the device near water Do not place the device near or over radiators or heat registers The device cabinet is provided with slots and openings to allow for adequate ventilation To ensure reliable operation and to protect against overheating these openings must never be blocked or covered The device should never be placed on a soft surface bed sofa
32. t USB hub that allows each of the computers to share any USB peripherals connected to the hub on a one computer at a time basis Recognizing the importance of sound the switches are also audio enabled A single microphone can provide audio input to each of the computers and you can listen to the audio output of each computer on a single set of speakers on a one at a time basis The CS 1742 CS 1744 s independent asynchronous switching feature allows independent switching of the KVM USB hub and audio focus If you wish you can give one computer the KVM console focus another the USB hub focus while a third has the audio focus Setup is fast and easy simply plug cables into their appropriate ports There is no software to configure no installation routines and no incompatibility problems Since the CS 1742 CS 1744 intercepts keyboard input directly it works on multiple operating platforms PC compatible Mac and Sun There are two convenient methods to access the computers push button port selection switches located on the unit s front panel and hotkey combinations entered from the keyboard Since a single console manages all of the computers the CS 1742 CS 1744 setup 1 eliminates the expense of having to purchase separate peripheral components for each computer 2 saves all the space those extra components would take up 3 saves on energy costs and 4 eliminates the inconvenience and wasted effort involved in constantly
33. uirements Safety information vi Computers 3 Restore Default Settings 20 T S Troubleshooting 30 Safety Instructions General iv U Rack Mounting vi USB Reset 19 Specifications 29 User Notice iii 34 CS 1742 CS 1744 User Manual Contents EGG Information sau sanada ESSE aaa ii WISER NOTICE rsss ii ta doo i aree kates ili Safety Instructions LL iv Generali io ee unta pa Roio iv Rack Mounting 0 vi Package Contents vii About this Manual 2 0 2 0 0 eee xi CONVENTIONS y sisi al a xii Getting Help x civic pad ead a eee ay xii 1 Introduction OVEIVICW sn eS cileni DE hte Soa pao letali debile eek ad lt 1 Features alii ie O E acai 2 Requirements sen ag a a a Sid papi a 3 A pere Sa 3 Computer s e aan La RA Le O La 3 Gables to Deal De E o Bo TE Ev 3 OS Sci a SR na a ia a ohne oa a 3 Components tl dir dn pad SUE E pad e da rea ita 4 Front VIEW Essa nen ele a a kee ae aaa ii 4 GSA OE ha exe cote A Bas DESDE and atte ae A 4 CSV TAA ee A css ar cs eid Atay 4 Rear VIEW snnt afraid 6 CSATA denti Ania ere e ie 6 GS ITA ee pi a FM e a oa 6 2 Hardware Setup Gable Connections cirie Saks Bhs eat 9 3 Basic Operation Manual Switching 0 0 11 Hot Pluggingi site los Beek Wa eel done Be a aa 11 Powering Off and Restarting 00 0 cece e eee eee 12 Port ID Numbering 02 0 c eee eee 12 4 Hotkey Operation Port Switching osor eir ecw eens ode ya dee See en 13 Cycling Through t
Download Pdf Manuals
Related Search
Related Contents
POJJO VVS-10012 Instructions / Assembly Sony VPL-ES3 LCD projector Copyright © All rights reserved.
Failed to retrieve file