Home
SMC EZ Connect Network Adapter
Contents
1. HP1D USB EZ Connect Powerline to USB Adapter E Install USB Drivers E install EZ Configuration Utility E View User Guide pdf E Install Acrobat Acrobat Reader E Install ZoneAlarm Pro E Visit www smc com Note If the CD does not Auto Run you can click on your CD ROM drive and double mouse click on the SMCHP1D USB exe icon to launch this splash screen The USB Drivers are not compatible with the Mac OS However if you want to manage your Powerline Adapter from a Mac you can use the SMC EZ Configuration Utility The EZ Configuration Utility for those operating systems are located on the CD ROM in there respective folders OSX and OS9 To install the utility follow the steps below 1 Click on the Install EZ Configuration Utility option on the splash screen shown above 2 On the SMC Logo screen click the Next button to start 3 Click the Next button again R SMC EZ Configuration Utility 1 0 InstallShield Wizard Welcome to the InstallShield Wizard for SMC EZ Configuration Utility 1 0 The InstallShield R Wizard will install SMZ EZ Configuration Utility 1 0 on your computer To continue click Next SMC WARNING This program is protected by copyright law and Networks international treaties SMC Networks SMC EZ HomePlug Configuration Manager 1 0 Software License Agreement This Agreement sets forth the terms and conditions under which the sotware know
2. in utility to troubleshoot your Powerline network CHAPTER 6 Understanding the Information in the SMC EZ Configuration Utility When you launch the EZ Configuration utility it will automatically scan your Powerline network for all the available Powerline adapters If a new Powerline device is added to your network it will automatically show up in the utility Device List The Powerline adapters are displayed in the Device List window The default device name is the Model number of the Powerline adapter There will be two types of devices displayed in your device list Local Device This is the Powerline device that is connected to the PC that you are using or if you are connect to a router and the Powerline device is connected to The local device will not have a Rate associated to it or require you to enter a device password to change the Network Password Remote Device house such as a PC These are Powerline adapters that are connected to other devices in your These devices will show you the Rate they are linked up at If you wish to change the Network Password on these units then you will have to enter the Device Password SMC EZ Configuration Utility 1 0 E l0 x Device List Dtfic eE OAMEC tic ir wE SMCHPID ETH 12 4 Office Connection Properties Password Mot Required Address 00 90 47 05 F1 79 Rename Gtate Connected Local Ethernet Access Delete Add Device
3. If you don t want to review the details click the Finish button to return to the main utility screen CHAPTER 10 Understand the Diagnostic Report The SMC Diagnostic report is exported to a text file called DiagnoticDetails txt You can use this report to review the details of your Powerline network and get help resolving connectivity issues Thu Dec 18 21 12 01 2003 smc EZ Configuration utility 1 0 Report gt gt gt Host Information App Name ConnectMan exe App Version V1 05 02 00 Host Name XXXXXXXXXX os Platform windows 2000 V5 0 Build 2195 Library Path C Program Files SMC HomePlug CSTDI d11 Library Version V5 03 16 5401 Driver Path C Program Files SMC HomePlug CSTDIPDS SYS Driver Version V5 03 16 54 Image Path gt CI PROGRA L SMC HomeP lug CSTDIPD5 SYS gt gt gt Host Network Connections Name Status Adapter Address IP Address Subnet Mask SMC1255TX Connected OQ0 04 E2 64 c1 1E 192 168 2 103 Pao ho Pe ae es Jee fe gt gt gt Powerline devices Name Device Address Interface Status Manufacturer Product SMCHPLD ETH 00 90 47 05 F1 79 Local Ethernet Connected SME HP1LD ETH SMCHPLD ETH 00 90 47 05 ED 91 Remote Connected SMC HPLD ETH gt gt gt Network Key Mismatch Test Passed no key mismatch detected gt gt gt Local Device SMCHP1D ETH Configuration Network Connection smMc1l255Tx Interface Type Local Ethernet Firmware Version C5110x Mac 1 1 1 4 OFFC 20030507 xxxRCc4 Hom
4. PC with USB port e CD ROM Note A CD ROM drive is only required if you want to install the EZ Configuration Utility from EZ Install CD This utility can also be downloaded from www smc com CHAPTER 2 Getting to Know the Powerline Adapter The SMCHP1D ETH EZ Connect Powerline to USB Desktop Adapter is the perfect solution for the home office environment This Powerline Adapter offers 1 USB 1 1 Connection LAN e 1 Powerline Connecter e LEDs for network status and troubleshooting Note You will need at least two SMC Powerline devices to create a Powerline network LED Indicators The Barricade includes LED indicators on the front panel that simplify installation and network troubleshooting ee kal os Solid LED indicates that the unit is powered on No LED light indicates the unit is powered off a bin Solid LED indicates that a Powerline signal is detected Blinking LED indicates traffic is being transmitted No LED light indicates no Powerline signal is not detected The USB Powerline Adapter receives power from the USB port on your PC so the PWR LED will come on when you connect this Adapter to the USB port not when you connect it to the power outlet in the wall The power cord that is connected to the power outlet is simply to link that PC to the Powerline network Resetting the Powerline Adapter To reset the SMC EZ Connect Powerline Adapter you will need to use the EZ Configuration Utility to reset the password to th
5. C 50 60Hz internal 0 15A Security 56 bit Data Encryption DES with Dynamic Key Management Protocols Forward Error Correction FEC Automatic Channel Adaptation Software Device Detect Diagnostic DEK Password Setup for Local and Remote Device Supports Windows 98 Me 2000 XP Mac OS 9 x and OS X 10 1 x Driver Supports Windows 98SE Me 2000 XP Operating Temperature 32 F to 104 F 0 C to 40 C Operating Humidity 10 to 90 Non Condensing Frequency 4 3 MHZ 20 9 MHZ Modulation OFDM Symbol Modulation Modulation Schemes DQPSK DBPSK ROBO Carrier Modulation Dimensions 3 05 x 4 53 x 98 in 77 5 x 115 x 25mm Weight 4 590z 130g Certifications FCC Part 15 Class B CE U L Certified Warranty Limited Lifetime Appendix B Compliances FCC STATEMENT This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determi
6. ET E mail addresses e techsupport smc com e european techsupport smc europe com Product Updates e http www smc com World Wide Web e http www smc com e http www smc europe com U S A and Canada Spain UK France Italy Benelux Central Europe Switzerland Nordic Northern Europe Eastern Europe Sub Saharan Africa North Africa Russia PRC Taiwan Asia Pacific Korea Japan Australia India 800 SMC 4 YOU 34 93 477 4935 44 0 118 974 8700 33 0 41 38 32 32 39 02 739 12 33 31 33 455 72 88 49 0 89 92861 0 1 9409971 868 70700 118 974 8700 34 93 477 4920 27 11 314 1133 34 93 477 4920 7 095 290 29 96 86 10 6235 4958 886 2 2659 9669 65 238 6556 82 2 553 0860 81 3 5645 5715 61 2 8875 7887 91 22 8204437 41 0 46 0 44 0 Fax 949 679 1481 Fax 34 93 477 3774 Fax 44 0 118 974 8701 Fax 33 0 41 38 01 58 Fax 39 02 739 14 17 Fax 31 33 455 73 30 Fax 49 0 89 92861 230 Fax 41 0 1 9409972 Fax 46 0 887 62 62 Fax 44 0 118 974 8701 Fax 34 93 477 3774 Fax 27 11 314 9133 Fax 34 93 477 3774 Fax 7 095 290 29 96 Fax 86 10 6235 4962 Fax 886 2 2659 9666 Fax 65 238 6466 Fax 82 2 553 7202 Fax 81 3 5645 5716 Fax 61 2 8875 7777 Fax 91 22 8204443 If you are looking for other contact information please visit www smc com
7. Mismatch Test Fail multiple network keys detected Local Device Model Configuration This section will outline the hardware information about the local Powerline Device The local Powerline device is typically the one connected directly to the PC the utility is used on However if you have a Powerline device connected to one of the LAN ports on your router and the PC is connected to the Router via a wired or wireless connection it will show the Powerline device connected to the Router as your local device gt gt gt Local Device SMCHPLD ETH Configuration Network Connection smMcl2557Tx Interface Type Local Ethernet Firmware Version C8110 Mac 1 1 1 4 oOFFC 20030507 gt oocRCd HomePlug MAC PHY CS 110200 Loopback Rate 1610 0 fps Cok Link Quality Summary Table In this section it the link quality for each Powerline device on your network is listed To improve your PHY Rate plug the Powerline adapter into another power outlet in your house gt gt gt Link Quality Summary Table Source Device Destination bevice PHY Rate mbps SMCHPLD ETH SMICHPLD ETH l3 4 SMCHPLD ETH SMCHPLO ETH 11 2 Bridge Information Summary Table In this section it you will get a complete summary of your Powerline network The reason the first Powerline Device shown below has 5 Bridged Addresses listed is because this Powerline device is connected to the LAN port of a Barricade Router gt gt gt Bridge Information summary Table D
8. Network Password Diagnostics Close Local Device SMC EZ Configuration Utility 1 0 E O x Device List al SUE Connection 12 4 SMCHP1D ETH Properties Password JHURWILIGWFTC Address 00 90 47 05 ED 91 Rename State Connected Powerline Access Delete Add Device Network Password Diagnostics Close Remote Device Device Names The SMC EZ Configuration Utility allows you to change the name of your Powerline devices to make them easier to manage For example if you have 4 Powerline adapters in your house you can give them a name that represents there locations To change the Device Name highlight the Powerline adapter in your Device list and click on the Rename button or right mouse click on the Device icon and select Rename Delete Devices You can also delete devices from the EZ Configuration Utility To do this simply highlight the Powerline adapter in your Device List and click on the Delete button or right mouse click on the Device icon and select Delete For more information on the other EZ Configuration Utility features see the sections outlined below CHAPTER 7 Add a Powerline Device The Add Device button is used to add a Powerline device to the EZ Configuration Utility before you connect the hardware to your network When you click the Add Device button the dialog box below will be displayed To add a device enter the Device Password
9. PTER 9 Running the Diagnostic Wizard CHAPTER 10 Understand the Diagnostic Report APPENDIX A Technical Specifications APPENDIX B Compliances APPENDIX C Technical Support CHAPTER 1 Introduction Congratulations on your purchase of an EZ Connect Powerline to USB Desktop Adapter SMCHP1D USB SMC is proud to provide you with a powerful yet simple communication device for creating a Powerline network that to extend the range of your wired or wireless network Features and Benefits EZ Configuration Utility Works on both Windows and Mac based PCs Plug and Play installation works out of the box Extends the range of your wired or wireless network Save time and money by using existing home wiring no need to run expensive CAT 5 cabling e Ideal solution for connecting your Game Console system to the Internet to play online games Package Contents Before installing the EZ Connect Powerline to USB Desktop Adapter verify that you have the items listed under Package Contents Also be sure that you have the necessary cabling If any of the items are missing or damaged contact your local SMC distributor EZ Connect Powerline to USB Desktop Adapter Powerline Cord One USB cable CD with User Guide and EZ Configuration Utility Quick Installation Guide If possible retain the carton and original packing materials in case there is a need to return the product Minimum Requirements e A Windows 98SE Me 2000 XP
10. SMGHP G USB EZ Gonneci 4Mbps Powerline to USB Adapter Copyright Information furnished by SMC Networks Inc SMC is believed to be accurate and reliable However no responsibility is assumed by SMC for its use nor for any infringements of patents or other rights of third parties which may result from its use No license is granted by implication or otherwise under any patent or patent rights of SMC SMC reserves the right to change specifications at any time without notice Copyright 2004 by SMC Networks Inc 38 Tesla Irvine CA 92618 All rights reserved Trademarks SMC is a registered trademark and EZ Connect is a trademark of SMC Networks Inc Other product and company names are trademarks or registered trademarks of their respective holders TABLE OF CONTENTS CHAPTER 1 Introduction Features and Benefits Package Contents Minimum Requirements CHAPTER 2 Getting to Know the Powerline Adapter LED Indicators Resetting the Powerline Adapter CHAPTER 3 Getting Connected Basic Installation Procedure Installing the USB Drivers CHAPTER 4 Installing EZ Configuration Utility Windows 98SE Me 2000 XP Macintosh Computer CHAPTER 5 Using the EZ Configuration Utility Launch the Utility Utility Layout CHAPTER 6 Understanding the Information in the SMC EZ Configuration Utility Device List Rename Devices Delete Devices CHAPTER 7 Add a Powerline Device CHAPTER 8 Setting a Network Password CHA
11. all devices are properly connected to AL outlets Please press Next to begin Back 2 Set the Network Password that you want to use The default network password is HomePlug Network Password x Change the Network Password by entering a new one in the edit bos Press Next to set the Network Password of all devices m the Device List Network Password lt Back Next gt Cancel Note It is highly recommended that you change this password from the default setting 3 This wizard will configure Network Passwords for the local adapter as well as the remote adapters in your Powerline network Network Password Setting password for device SMCHPID ETH Password successtully changed Setting password for device SMCHPID ETH Password successtully changed Note You can only set passwords for remote Powerline devices if you have the Device Password DEK configured in the SMC EZ Configuration Utility For information on how to do this please refer to the previous section When the wizard has completed click the Finish button to return to the EZ Configuration Utility CHAPTER 9 Running the Diagnostic Wizard The SMC EZ Configuration Utility has a built in diagnostic tool to help you trouble shoot your Powerline network To access this tool and detailed report follow the steps outlined below 1 After you click the Diagnostics button on the default utility page the P
12. and press Add The password is located on the device or its packaging Device Password Add Network Password H omeFlug Done To add a Powerline device to your network you will need to enter in the Device Password The Device password is listed on the lablel on the back of your Powerline device On the SMCHP1D ETH and SMCHP1D USB the Device Password is listed as DEK XXXXXXXXXXXX Note DEK stands for Device Encryption Key Once you have added the Powerline hardware to the EZ Configuration Utility then you can connect the actual unit in the remote location where it is needed to extend your network connection over the Powerline network By using this feature you can easily setup a Powerline network with the EZ Configuration Utility and setup and manage the network very efficiently CHAPTER 8 Setting a Network Password When you click the Network Password button the Network Password wizard will launch This wizard is used to change the Security Key for all the devices configured with the EZ Configuration Manger Before then remote Powerline device s security network password can be changed with this wizard the Device Password must be configured in the utility 1 Click the Next button to start the wizard Network Password e x Set Powerline Hetwork Password wizard This wizard allows pou to change the Network Password used by all devices on your Powerline newark Before running the wizard check that
13. e default setting of HomePlug CHAPTER 3 Getting Connected The EZ Connect Powerline to USB Adapter is connected between the USB port on your Windows based PC and the Powerline Network The Powerline network is automatically created once you plug in the first Powerline Device Power cord COMPUTER connected to connected to Powerline Port n USB Port Basic Installation Procedure 1 CONNECT the LAN Connect an USB cable from your PC to the Powerline to USB Adapters USB 1 1 port on the back on the device 2 CONNECT the Powerline Run the included Power cord from the Powerline connector on the Adapter to an available power outlet in your home Note For best performance connect device directly to wall outlet Do not connect to surge protector power bar Installing USB Driver To install the USB drivers for the SMC EZ Connect Powerline to USB Adapter follow the steps outlined below 1 Put the EZ Install CD into your CD ROM drive The wizard will auto run Click on the Install USB Drivers option 3 When the USB drivers are installed you will be prompted to connect your SMACHP1D USB adapter to your PC and then reboot your PC Install Completed x Please shut down your PC and insert your adapter Click OK and then close all your open applications and manually reboot your PC 4 When you computer boots back up the New Hardware wizard should launch and guide you through the installation of the USB Adap
14. ePlug Mac PHY C5110200 Loopback Rate 1610 0 fps OK gt gt gt Link Quality Summary Table Source Device Destination Device PHY Rate Mbps SMCHPLD ETH SMCHPLD ETH 13 4 SMCHPLD ETH SMCHPLD ETH ake 2 gt gt gt Bridge Information Summary Table Device Name Device Address Bridged Address IP Address SMCHPLD ETH 00 90 47 05 F1 79 00 30 1B 11 34 86 192 168 2 101 00 20 E0 88 DB AA UNKNOWN 00 04 E2 64 C1 1E 192 168 2 103 user 00 70 46 00 00 O01 192 168 2 1 00 07 95 D8 A 7 AA UNKNOWN SMCHPLD ETH 00 90 47 05 ED 91 None UNKNOWN Diagnostic Summary Report No problems encountered with the powerline network This report has eight sections which are listed below e Host Information e Host Network Connections e Powerline Devices e Network Key Mismatch Test e Local Device Configuration e Link Quality Summary Table e Bridge Information Summary Table e Diagnostic Summary Report Host Information This section provides information about SMC EZ Configuration Utility and the PC you are running the utility on l E gt gt gt Host Information App Name gt ConnectMan exe App Version VL 05 02 00 Host Name i xxx E EEX os Platform windows 2000 V5 0 Build 2195 Library Path Ci Pragram Files sMmc HomePlug csSTOI dl Library version w5 03 16 5401 Driver Path Ci Proagram Fi lesssMcC HomePlugycsTDIPDS SYS Driver Version v5 03 16 54 Image Path COP PACINPROGRA LSSMC HomeP lug cSTDIPDS SYS Host Network C
15. ewice Name Device Address Bridged Address IF Address SMCHPLO ETH OO 90 4 O5 Fl 9 O0 s0 1B 11 s4 86 192 158 2 101 O00 20 E0 88 DB 44 UNKNOWN O0 04 E2 64 C1 1E 192 168 2 103 Cuser O0 0 46 00 00 01 192 168 2 1 O0 O07 G5 De A 44 UNKNOWN SMICHPLO ETH O0 90 4 05 ED 91 None UNE Mow Diagnostic Summary Report This section of the diagnostic report will outline any steps required to fix a connectivity issue For example if you fail the Network Key Mismatch Test this section will provide an explanation of the issue display which device has the wrong password and provide a method to resolve this issue Diagnostic summary Report gt gt gt Multiple keys detected At least one device connected to the powerline 1s using a Network Password that is different than the Network Password used by the local adapter Use the Network Manager Add Device function to set the Network Password of all new devices connected to the powerline gt gt gt Deyice SMCHPLO ETH is using a different Network Password Use the Network Manager Network Password function to set the correct Network Password for this device Appendix A Product Specification Below is an outline of the Technical Specifications for the EZ Connect Powerline to USB Desktop Adapter SMCHP1D USB Standards HomePlug v1 01 compatible USB 1 1 Interface USB 1 1 Electrical plug Powerline LEDs Power PWR HomePlug LINK ACT HP Power Input 100 240VA
16. n as SMC EZ HomePlug Configuration Manager 1 0 1 SMC maintains all rights ttle and interest in and to SMC EZ HomePlug Configuration Manager 1 0 including all applicable copyrights trade secrets patents and other intellectual rights therein Ido not accept the terms in the license agreement Installshield lt Back Cancel 5 Enter in the Username and Organization information and set access rights then click the Next button to continue 6 Confirm the installation location and then click the Next button to continue Default install location is C Program Files SMC j SMC EZ Configuration Utility 1 0 InstallShield Wizard r SMC Networks Install SMC EZ Configuration Utility 1 0 to C Program Files SMC Change Installshield i Cancel Note You can change the installation location by clicking the Change button 7 Confirm the Installation information Then click the Install button to begin the process 8 To complete the Installation click the Finish button ia SMC EZ Configuration Utility 1 0 InstallShield Wizard InstallShield Wizard Completed The InstallShield Wizard has successfully installed SMC EZ Configuration Utility 1 0 Click Finish to exit the wizard Cancel 9 When finished you must restart your computer to finalize the installation Click the Yes button to reboot your PC ia SMC EZ Configuration Utility 1 0 Installer Informa
17. ned by turning the equipment off and on the user is encouraged to try to correct the interference by one of the following measures e Reorient or relocate the receiving antenna e Increase the separation between the equipment or device e Connect the equipment to an outlet other than the receiver s e Consult a dealer or an experienced radio TV technician for assistance This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation FCC Caution Any changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate this equipment IMPORTANT NOTE FCC Radiation Exposure Statement This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment This equipment should be installed and operated with a minimum distance of 20 centimeters 8 inches between the radiator and your body This transmitter must not be co located or operating in conjunction with any other antenna or transmitter Appendix C Technical Support PHONE From U S A and Canada 24 hours a day 7 days a week e 800 SMC 4 YOU e 949 679 8000 e Fax 949 679 1481 From Europe 8 00 AM 5 30 PM UK Time e 44 0 118 974 8700 e Fax 44 0 118 974 8701 INTERN
18. onnections This section will outline the model name if you are connected the MAC Address IP Address and Subnet Mask for the Network Adapter installed on your PC gt gt gt Host Network Connections Name Status Adapter Address IF Address Subnet Mask SMELTE Connected O0 04 E2 64 Cl 1E 192 168 272 103 2A Ae oN ee eh lar Powerline Devices This section lists out the Powerline devices on your network In this section on the diagnostic report you will get the Device Name Device Address MAC Address Interface Status Manufacture and Product Model of your Powerline device This section is useful to check the status of all your Powerline devices to insure they are connected and operating correctly gt gt gt Powerline deyices Mame Deyice Address Interface Status Manufacturer Product SMCHPLO ETH O0 90 47 05 FL 9 Local Ethernet Connected SMZ HPLO ETH SMCHPLO ETH oO GO 4 0O5 ED SlL Remote Connected SMZ HPLO ETH Network Key Mismatch Test This section will display the results of the Network Key test This test will check to confirm if each Powerline device on network has the same encryption key Positive Results Network is configured correctly gt gt gt Network Key Mismatch Test Passed no key mismatch detected Negative Results Power network is not configured correctly Please refer to the summary section at the bottom of the Diagnostic Report to see which device has the wrong password gt gt gt Network Key
19. owerline Diagnostics Wizard will launch To start the wizard click the Next button Powerline Diagnostics x Powerline Connection Diagnostics Wizard This wizard performs diagnostics on Powerline devices attached directly this PC and any devices accessible via the power line Before running the diagnostics check that all devices are properly connected tis very important that devices be directly connected to AC outlets and not to a power bar Please press Next to begin Powerline Diagnostics E o x Process responses from remote devices and hosts Gathering host system information Venting local device contiguration and performance Building link quality table Building bridging mformation table Creating diagnostic summary 3 When the scan has completed click the Next button to view the report summary Powerline Diagnostics x Diagnostics complete Press Next to view the Summar Report Gathering host system information Verifying local device configuration and performance Building link quality table Building Bridging information table Creating diagnostic summary 4 The report summary will tell you in there is anything wrong with your Powerline network To access a complete report click the Detail Report button Powerline Diagnostics Diagnostic Summary Report No problems encountered with the powerline network Detail Report 2 Back Next gt alates
20. ter During the Driver Installation if you are prompted with following window Hardware Installation AN The software you are installing for this hardware SMC Powerline to USB Adapter has not passed Windows Logo testing to verify its compatibility with Windows eP Lell me why this testing is important Continuing your installation of this software may impair or destabilize the correct operation of your system either immediately or in the future Microsoft strongly recommends that you stop this installation now and contact the hardware vendor for software that has passed Windows Logo testing Continue Anyway Click the Continue Anyway button to complete the installation Note If the wizard is unable to locate the USB drivers you can manually install the drivers by browsing to the Drivers folder on the CD ROM When you have finished installing the USB to Powerline Adapter if this is the PC you are going to manage your Powerline network from then install the EZ Configuration Utility steps are outlined below CHAPTER 4 Installing EZ Configuration Utility Windows 98SE Me 2000 XP The screen shots were taken on a Windows 2000 machines but the same steps apply will apply for Windows 98SE Me and XP To access the User Guide and install the EZ Configuration Utility just insert the CD into your CD ROM drive and the Auto run splash screen will appear EZ Connect Powerline to USB Adapter SMC Networks
21. tion You must restart your system For the configuration changes made to SMC EZ Configuration Utility 1 0 bo take effect Click Yes to restart now or Mo if vou plan to restart later When you computer finishing restarting the installation is complete and you can now use this utility to configure your Powerline network CHAPTER 5 Using the EZ Configuration Utility To access the EZ Configuration Utility follow the steps below 1 Click on the Start button P Choose Programs SMC EZ 3 Select the SMC EZ HomePlug Configuration Manager 1 0 folder and hia then click on the SMC EZ HomePlug Configuration Manager 1 0 icon Note Before you run this utility please make sure that you have a SMC Powerline device connected directly to the PC The SMC EZ Configuration Utility window is shown below With this utility you can configure and manage all of your SMC Powerline devices SMC EZ Configuration Utility 1 0 5 x This section will show the Device List available Powerline devices Rate Devic on your network pe ME SMCHPID ETH Tals SMCHPID ETH 11 6 Mbps SMCHFIC ETH Properties The Add Device button znd aeda allows you to add remote Powerline devices Address 00 90 47 05 F1 79 Rename Crate Connected Local Ethernet Access Delete x The Network Password Add Device button gt Network Password Diagnostics Close The Diagnostics button launches the built
Download Pdf Manuals