1. INSTALLATION FROM ACCESSIBLE ROD AREA ABOVE Using headers 1 From below drill a small hole in ceiling at the planned location Stick clothes hanger through hole to help locate the area from above 2 Locate hole in attic or crawl space 3 Refer to Figure 7 In attic or crawl space mark ceiling for cutout by using the housing as a template Cutout dimensions 10 6 x 14 The short side 10 6 or cutout must be next to the ceiling joist 4 Make cutout along marked line NOTE Refer to Figure 3 If ceiling is plaster cutout should be made from below to avoid chipping plaster 5 Refer to Figure 7 Install headers between joists using nails or screws leaving 10 6 between them 6 Refer to Figure 7 The mounting brackets must be mounted on the long sides of the housing NOTE Each of the mounting brackets are secured by two 2 hex nuts 7 Refer to pages 1 and 2 Mount damper section to housing install housing and connect wiring and ducting Install power unit blower assembly and grille HOOK HANGER RODS FROM INSIDE TO HANGER ROD FIGURE 6 HEADER FIGURE 7 U One Year Limited Warranty WARRANTY OWNER NuTone warrants to the original consumer purchaser of its products that such products will be free from defects in materials or workmanship for a period of one 1 year from the date of original purchase THERE ARE NO OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO IMPLIED WARRANTI
2. U INSTALLATION INSTRUCTIONS READ amp SAVE THESE INSTRUCTIONS Quiel Test Combination Fan Light with Night Light MODEL QT140L SUITABLE FOR USE OVER TUB OR SHOWER ENCLOSURE WHEN INSTALLED IN A GFCI PROTECTED BRANCH CIRCUIT e Suitable for use with solid state speed controls Not for use in kitchens e Uses standard 3 x 10 ducting e Designed for ceiling installation IMPORTANT SAFETY INSTRUCTIONS WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR INJURY TO PERSONS OBSERVE THE FOLLOWING A Use this unit only in the manner intended by the manufacturer If you have questions contact the manufacturer B Before servicing or cleaning unit switch power off at service panel and lock service panel to prevent power from being switched on accidentally When the service disconnecting means cannot be locked securely fasten a prominent warning device such as a tag to the service panel CAUTION For general ventilating use only Do not use to exhaust hazardous or explosive materials and vapors INSTALLATION INSTRUCTIONS WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR INJURY TO PERSONS OBSERVE THE FOLLOWING A Installation work and electrical wiring must be done by qualified person s in accordance with all applicable codes and standards including fire rated construction B Sufficient air is needed for proper combustion and exhausting of gases through the flue chimney of fuel burning eq
3. Asociaci n Norteamericana de Ingenieros de Calefacci n Refrigeraci n y Aire Acondicionado ASHRAE y por las autoridades de c digos locales C Cuando corte o taladre en la pared o el techo no da e el cableado el ctrico ni otros servicios escondidos D Los ventiladores entubados siempre deben estar ventilados hacia el exterior E Si la unidad se va a instalar encima de una ba era o ducha E aqu lla debe estar se alada como apropiada para la aplicaci n No coloque NUNCA un interruptor donde pueda ser alcanzado desde la ba era o ducha PARA OBTENER MEJORES RESULTADOS En la construcci n nueva instale la caja unidad de potencia durante la etapa de enterramiento de la instalaci n el ctrica del edificio El conjunto de l mpara y la rejilla deben de instalarse despu s de que el techo acabado est en su sitio La instalaci n en un edificio avabado ya existente requiere un rea accesible tico o s ntano de peque a altura que queda entre el primer piso y el terreno natural sobre la localizaci n planeada Consulte INSTALACION EN UNA CONSTRUCCION EXISTENTE INSTRUCCIONES DE INSTALACION LEA Y GUARDE ESTAS INSTRUCCIONES UNIDAD DE POTENCIA CONECTADOR DE POTENCIA He P lt RANURA TUERCA DE MARIPOSA VARILLA DE SUSPENSION VARILLA DE SUSPENSION FIGURA 1 DESCARGA CAPERUZA VERTICAL CONDUCTO DE 3 X 10 CAPERUZA DE PARED CAJA DEL VENTILADOR DESCARGA HOR
4. contraria a las instrucciones de instalaci n recomendadas La duraci n de cualquier garant a no expresada est limitada a un per odo de un a o seg n se especifica en la garant a expresada Algunos estados no permiten limitaci n en cuanto a la duraci n de una garant a no expresada por lo que la limitaci n arriba indicada puede que no se aplique a Ud LA OBLIGACI N DE NUTONE DE REPARAR O REEMPLAZAR A SU OPCI N SER EL NICO Y EXCLUSIVO RECURSO QUE TENDR EL COMPRADOR BAJO ESTA GARANTIA NUTONE NO SERA RESPONSABLE POR DANOS INCIDENTALES CONSECUENTES O ESPECIALES QUE RESULTEN A CONSECUENCIA O SEAN INDEPENDIENTE DEL USO O DESEMPE O DEL PRODUCTO Algunos estados no permiten la exclusi n o limitaci n de da os incidentales o consecuentes de modo que la limitaci n o exclusi n arriba indicada pueda que no se aplique a Ud Esta garant a le proporciona derechos legales espec ficos y Ud puede tener otros derechos los cuales var an de estado a estado Esta garant a reemplaza a todas las garant as anteriores SERVICIO DE GARANT A Para tener derecho al servicio de garant a Ud debe a Notificar a NuTone a la direcci n indicada m s abajo o al tel fono 1 800 543 8687 b indicar el n mero de modelo y la identificaci n de la parte y c describir la naturaleza de cualquier defecto en el producto o parte Al momento de solicitar el servicio por la garant a Ud debe presentar la evidencia de la fecha original de compra Fecha d
5. e No se puede utilizar en cocinas e Utiliza un conducto est ndar de 3 x 10 e Dise ado para la instalaci n en techos INSTRUCCIONES IMPORTANTES DE SEGURIDAD ADVERTENCIA PARA REDUCIR EL RIESGO DE INCENDIO CHOCQUE ELECTRICO O LESIONES A LAS PERSONAS OBSERVE LO SIGUIENTE A Utilice esta unidad solamente de la manera planeada por el fabricante Si tiene alguna pregunta p ngase en contacto con el fabricante B Antes de reparar o limpiar la unidad apague la corriente del panel de servicio y cierre con llave el panel de servicio par evitar que la corriente se encienda accidentalmente PRECAUCION Solamente para ventilaci n general No lo utilice para expulsar materiales y vapores peligrosos o explosivos INSTRUCCIONES DE INSTALACION ADVERTENCIA PARA REDUCIR EL RIESGO DE INCENDIO CHOQUE ELECTRICO O LESIONES A LAS PERSONAS OBSERVE LO SIGUIENTE A El trabajo de instalaci n y el cableado el ctrico deben ser realizados por una s persona s calificada s de acuerdo con todos los c digos y est ndares aplicables incluyendo la contrucci n seg n los est ndares contra incendios B El flujo del aire de combusti n necesario para el manejo seguro del equipo quemador de combustible puede verse afectado por el funcionamiento de esta unidad Siga las pautas y est ndares de seguridad del fabricante para el equipo de calefacci n como las publicadas por la Asociaci n Nacional de Portecci n contra Incendios NFPA por la
6. la Figura 7 Las consolas para el montaje deben montarse en los lados largos del alojamiento NOTA Cada una de las consolas de montaje se fijan con dos 2 tuercas hexagonales 7 Refi rase a las p ginas 1 y 2 Monte la secci n del regulador de tiro en la caja instale la caja y conecte el E cableado y el conducto Instale la unidad de potencia FIGURA 7 el conjunto del ventilador y la rejilla Nulone Garant a Limitada de un A o GARANT A DEL PROPIETARIO NuTone garantiza al comprador consumidor original de sus productos por el per odo de un 1 a o desde la fecha original de compra que tales productos est n libres de defectos en material y mano de obra NO HAY OTRAS GARANTIAS EXPRESADAS O SOBREENTENDIDAS INCLUYENDO PERO NO LIMITADAS A GARANTIAS NO EXPRESADAS DE MERCANTIBILIDAD O ADAPTABLES A UN PROPOSITO EN PARTICULAR Durante este per odo de un a o NuTone reparar o reemplazar a su opci n y sin costo cualquier producto o parte que se encuentre defectuoso bajo condiciones normales de uso y servicio ESTA GARANT A NO CUBRE A LOS ARRANCADORES PARA L MPARAS FLUORESCENTES O A LOS TUBOS FLUORESCENTES FILTROS DUCTOS TAPAS DE TECHO TAPAS DE PARED Y OTROS ACCESORIOS PARA CANALIZACI N Esta garant a no cubre a Mantenimiento y servicios normales b Productos o partes sujetos al mal uso negligencia accidente mantenimiento inadecuado o reparaciones por otros ajenos a NuTone instalaci n defectuosa o a una instalaci n
7. wall or through roof and mount appropriate wall or roof cap optional IMPORTANT Be sure nothing obstructs the discharge of the unit Make sure the insulation does not get into the ductwork or into the blower unit WIRING NOTE All wiring connections must comply with local codes ordinances and the National Electric Code and the unit must be properly grounded 1 Loosen screws and remove junction box 2 Run 120vAC supply wiring with ground through switch box to e VENTILATOR knockout in ventilator housing and secure with box connector EE HOUSING 3 Refer to Figure 5 Connect supply wires to the unit s wires Black a to black white to white Connect ground to green ground lead MOUNTING 4 Replace junction box tighten screws BRACKET 5 Connect supply wire to a listed general use wall switch in switch box or use a listed timer suitable for the voltage and current rating of the fan POWER UNIT INSTALLATION 1 Refer to Figure 6 The Power Unit mounts with two hanger rods to the mounting brackets Insert the hanger rods through the holes in the mounting bracket 2 Position the power unit so that its discharge opening is in line with the installed ductwork Hold the power unit in position between the mounting brackets and swing the hanger rods into the slots on the power unit and securely tighten the wing nuts 3 Plug the three wire connector from the junction box into the three FIGURE 4 wire connector from the power unit m
8. ES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE During this one year period NuTone will at its option repair or replace without charge any product or part which is found to be defective under normal use and service THIS WARRANTY DOES NOT EXTEND TO FLUORESCENT LAMP STARTERS OR TUBES FILTERS DUCT ROOF CAPS WALL CAPS AND OTHER ACCESSORIES FOR DUCTING This warranty does not cover a normal maintenance and service or b any products or parts which have been subject to misuse negligence accident improper maintenance or repair other than by NuTone faulty installation or installation contrary to recommended installation instructions The duration of any implied warranty is limited to the one year period as specified for the express warranty Some states do not allow limitation on how long an implied warranty lasts so the above limitation may not apply to you NUTONE S OBLIGATION TO REPAIR OR REPLACE AT NUTONE S OPTION SHALL BE THE PURCHASER S SOLE AND EXCLUSIVE REMEDY UNDER THIS WARRANTY NUTONE SHALL NOT BE LIABLE FOR INCIDENTAL CONSEQUENTIAL OR SPECIAL DAMAGES ARISING OUT OF OR IN CONNECTION WITH PRODUCT USE OR PERFORMANCE Some states do not allow the exclusion or limitation of incidental or consequential damages so the above limitation or exclusion may not apply to you This warranty gives you specific legal rights and you may also have other rights which vary from state to state This warranty supersedes all prior warranti
9. IZONTAL INSTALACION EN UN LUGAR DE CONTRUCCION NUEVA Preparacion del conjunto de la caja PRECAUCION Cuando maneje la unidad de potencia no toque las aberturas de los extremos ni doble las rudeas del ventilador 1 Refierase a la Figura 1 Quite la unidad de potencia del conjunto de la caja A Si es necisario desenchufe la clavija de toma de corriente del conectador de acoplamiento B Afloje las tuercas de mariposa de las varillas de suspension que sostienen la unidad de potencia C Suelte las varillas de suspension de las ranuras y quite la unidad de potencia D Ponga la unidad de potencia a un lado hasta que la necesite 2 Quite uno de los agujeros ciegos del cableado de la caja 3 Refierase a la Figura 2 En esta unidad el conducto se puede colocar para descarga vertical u horizontal Determine el m todo de descarga que se utilizara 4 Refierase a la Figura 3 Monte la seccion del regulador de tiro de 3 x 10 sobre la caja para la descarga vertical o en el lado de la caja para la descarga horizontal con dos 2 tornillos incluidos MONTAJE DE LA CAJA NOTA Esta unidad est dise ada para la instalaci n entre viguetas de techo separadas 16 entre los centros sin necesidad de armaz n Si la estructura del edificio tiene una construcci n de viguetas separadas 24 entre los centros ser necesario un armaz n 1 Coloque la caja entre las viguetas de techo y ajuste la altura al techo acabado Afloje dos 2
10. aking sure plug is properly aligned MOUNTING THE GRILLE ASSEMBLY 1 Place the reflector into the grille RECEPTACLE 2 Insert light plug and night light plug into receptacles 3 Using two provided screws secure grille and reflector to housing 4 Install 100 watt maximum light bulb into light socket 5 Install 7 watt maximum C 7 candelabra type bulb into night light socket 6 Snap lens into place MAINTENANCE Disconnect the power before cleaning or performing any maintenance on the unit If the grille becomes soiled use only a mild soap and water solution for cleaning Do not use solvents or abrasive cleaners FIGURE 3 SWITCH BOX I O N E I 9 l TO NIGHT FIGURE 5 INSTALLATION IN EXISTING T CONSTRUCTION BRACKET Installing the unit in an existing house requires at least a small accessible area attic or crawl space above the planned installation location Review INSTALLATION IN A NEW CONSTRUCTION SITE and follow all instructions which apply to your installation LOCATION Locate ventilator next to a ceiling joist WIRING AND DUCTING Refer to Figure 6 for wiring and to Figure 2 for ducting Plan ducting and wiring before proceeding with installation CAUTION Check area above planned installation to be sure that 1 Ducting can be installed 2 Wiring can be run to the planned location 3 No wiring or other obstruction might interfere with installation HANGER
11. bly A If necessary unplug power plug from mating connector B Loosen wing nuts on hanger rods that hold the power unit C Unfasten hanger rods from slots and remove power unit D Set power unit aside until needed 2 Remove one of the wiring knockouts from the housing 3 Refer to Figure 2 This unit can be ducted for either vertical or horizontal discharge Determine the method of discharge that will be used 4 Refer to Figure 3 Mount 3 x 10 damper section on top of housing for vertical discharge or on the side of housing for horizontal discharge with two 2 screws furnished MOUNTING THE HOUSING VERTICAL DISCHARGE NOTE This unit is designed for installation between 16 OC ceiling 3 X 10 DAMPER joists with no framing necessary if the building structure has 24 OC SECTION joist construction framing will be required 1 Position housing between ceiling joists and adjust height to finished ceiling Loosen two 2 hex nuts for each mounting bracket from inside the housing and make the adjustment Tighten the four 4 hex nuts 314 X 10 NOTE There are four 4 extra mounting slots in the housing long D AMPER sides for mounting or relocating the mounting brackets SECTION 2 Refer to Figure 4 Screw housing to joists using holes in mounting brackets and four 4 screws furnished 3 Refer to Figure 2 and mounting instructions included with caps Install standard 3 x 10 ductwork from damper section to outside
12. e instalaci n Constructor o instalado N de modelo y descripci n del producto SI NECESITA ASISTENCIA O SERIVIVIO Para obtener la localizaci n del Centro de Servicio Autorizado Los residentes de los Estados Unidos contiguos llam gratis al 1 800 543 8687 Por favor est preparado para suministrar Fecha y prueba de compra La naturaleza de la dificultad Los residentes de Alaska o Hawaii deben escribir a NuTone Inc Attn Department of National Field Service 4820 Red Bank Road Cincinnati Ohio USA 45227 1599 Los residentes de Canada Ecrivez a Broan NuTone Canada 1140 Tristar Drive Mississauga Ontario Canada L5T 1H9 Rev 03 2001 Las especificaciones del producto est n sujetas a cambio sin previo aviso 4820 Red Bank Road Cincinnati Ohio 45227 Impreso en los EE UU
13. e techo CABLEADO Y CONDUCTO Refi rase a la Figura 6 para el cableado y a la Figura 2 para el conducto Planee el conducto y el cableado antes de continuar con la instalaci n PRECAUCION Compruebe el rea sobre la instalaci n planeada para asegurarse de que 1 El conducto se puede instalar o el rea es suficiente VARILLA DE para el montaje adecuado SUSPENSION INIDADDE 2 El cableado se puede llevar a la ubicaci n planeada y lt POTENCIA 3 Ning n cableado ni otra obstrucci n puede interferir con la instalaci n INSTALACION DESDE UN AREA 7 FIGURA 6 SUPERIOR ACCESIBLE Utilizando soportes 1 Desde abajo taladre un agujero de menos en el techo en el lugar planeado Meta una percha para colgar la ropa por el agujero para ayudarle a localizar el rea desde arriba 2 Localice el agujero en el tico o s tano de peque a altura 3 Refi rase a la Figura 7 En el tico o en el s tano de peque a altura marque el techo para el recorte utilizando la caja como plantilla Recorte las dimensiones 10 6 x 14 El lado corto 10 6 o el recorte debe estar junto a la vigueta de techo SOPORTE 4 Haga el recorte a lo largo de la l nea marcada 7 NOTA Refi rase a la Figura 3 Si el techo es de yeso el recorte se debe hacer desde abajo para evitar las virutas del yeso 5 Refi rase a la Figura 7 Instale los soportes entre las viguetas utilizando clavos o tornillos dejando 10 entre ellos 6 Refi rase a
14. es WARRANTY SERVICE To qualify for warranty service you must a notify NuTone at the address stated below or telephone 1 800 543 8687 b give the model number and part identification and c describe the nature of any defect in the product or part At the time of requesting warranty service you must present evidence of the original purchase date Date of Installation Builder or Installer Model No and Product Description IF YOU NEED ASSISTANCE OR SERVICE For the location of your nearest NuTone Independent Authorized Service Center Residents of the contiguous United States Dial Free 1 800 543 8687 Please be prepared to provide Product model number Date and Proof of purchase The nature of the difficulty Residents of Alaska or Hawaii should write to NuTone Inc Attn Department of National Field Service 4820 Red Bank Road Cincinnati Ohio 45227 1599 Residents of Canada should write to Broan NuTone Canada 1140 Tristar Drive Mississauga Ontario Canada L5T 1H9 M_ ANINNNA Product specifications subject to change without notice 4820 Red Bank Road Cincinnati Ohio 45227 Printed in U S A Rev 04 01 Part No 35746 U Combinaci n L mpara Ventilador QuielTest con iluminaci n nocturna MODELO QT140L APROPIADO PARA SER UTILIZADO EN EL RECINTO DE LA BANERA O DE LA DUCHA CUANDO SE INSTALA EN UN CIRCUITO DERIVADO PROTEGIDO POR GFCI Apropiado para usarla con controles de velocidad de estado s lido
15. tuercas hexagonales para cada consola para el montaje desde el interior de la caja y haga el ajuste Apriete las cuatro 4 tuercas hexagonales NOTA Hay cuatro 4 ranuras extras de montaje en los lados largos de la caja para montar o cambiar de sitio las consolas para el montaje 2 Refi rase a la Figura 4 Atornille la caja a las viguetas utilizando los agujeros de las consolas para el montaje y cuatro 4 tornillos incluidos 3 Refi rase a la Figura 2 y a las instrucciones para el montaje incluidas con las caperuzas Instale el conducto est ndar de 3 x 10 desde la secci n del regulador de tiro hasta la pared exterior o a trav s del tejado y monte la caperuza de pared o tejado opcional INPORTANTE Aseg rese de que nada obstruya la descarga de la unidad Aseg rese de que el aislamiento no entre en el conducto ni en la unidad del ventilador CABLEADO NOTA Todas las conexiones del cableado deben cumplir con los c digos y las ordenanzas locales y con el reglamento de instalaciones el ctricas nacionales y la unidad debe estar puesta a tierra adecuadamente 1 Afloje los tornillos y saque la caja de empalme 2 Pase un cableado de 120v CA con conexi n a tierra a trav s de la caja del interruptor al agujero ciego en la caja del ventilador y f jelo con un conectador de caja 3 Refi rase a la Figura 5 Conecte los cables de alimentaci n a los cables de la unidad Negro con negro blanco con blanco Conecte la p
16. uesta a tierra con el conductor verde de conexi n a tierra 4 Vuelva a colocar la caja de empalme apriete los tornillos 5 Conecte el cable de alimentaci n a un interruptor de pared certificado de uso general en la caja del interruptor o utilice un temporizador certificado apropiado para el voltaje y el tipo de corriente del ventilador INSTALACION DE LA UNIDAD DE POTENCIA 1 Refi rase a la Figura 6 La unidad de potencia se monta con dos varillas de suspensi n en la consola de montaje Inserte las varillas de suspensi n a trav s de los agujeros de la consola de montaje 2 Coloque la unidad de potencia de manera que la abertura de descarga est alindeada con el conducto instalado Sostenga la unidad de potencia en su lugar entre las consolas de montaje y gire las varillas de suspensi n para introducirlas en las ranuras de la unidad de potencia y apriete bien las tuercas de mariposa 3 Enchufe el conector de tres hilos de la caja de empalme en el conector de tres hilos de la unidad de potencia asegur ndose de que el enchufe est bien alineado MONTAJE DEL CONJUNTO DE LA REJILLA 1 Coloque el reflector en la rejilla 2 Inserte el enchufe de la luz y el enchufe de la luz nocturna en los recept culos 3 Utilizando dos tornillos incluidos fije la rejilla y el reflector a la caja 4 Instale una bombilla de 100 watt m ximo en el portal mparas 5 Instale una bombilla tipo candelabre C 7 de 7 watt m aximo en el ench
17. ufe de iluminaci n nocturna 6 Presione la lente hasta que quede en su sitio MANTENIMIENTO Desconecte la corriente antes de limpiar o realizar cualquier clase de mantenimiento en la unidad e Sila rejilla se ensucia use solamente una soluci n de jab n suave y agua para la limpiarla No utilice disolventes ni limpiadores abrasivos SECCION DEL REGULADOR DE TIRO DE 3 X 10 DE LA DESCARGA VERTICAL SECCION DEL REGULADOR DE TIRO DE 3 X 10 FIGURA 3 CAJA DEL VENTILADOR FIGURA 4 RECEPTACULO RECEPTACULO DE DE LA LUZ LA LUZ NOCTURNA RECEPTACULO DE VENTILACION DU CAJA DEL INTERRUPTOR oc O E oO cc co Lu zZ Lu a O lt x lt HACIA EL INTERRUPTOR DE ILUMINACION NOCTURNA HACIA EL INTERRUPTOR DEL VENTILADOR BLANCO CABLE PUESTO NEUTRO A TIERRA DEL EMPLAZAMIENTO FIGURA 5 INSTALACION EN UNA CONSTRUCCION CONSOLA PARA EL MONTAJE EXISTENTE _ _ _ oOo oo ENGANCHE LAS La instalaci n de la unidad en una casa existente requiere E SN al menos un rea peque a accesible tico o s tano de DESDE FUERA peque a altrua que queda entre el primer piso y el terreno HACIA Joy natural sobre la localizacion de la instalacion planeada DENTRO PELA VARILLA Repase INSTALACION EN UN LUGAR DE EIA gt DE SUSPENSION CONSTRUCCI N NUEVA y siga todas las instrucciones E que correspondan a su instalaci n UBICACION Coloque el ventilador junto a una vigueta d
18. uipment to prevent back draft Follow the heating equipment manufacturer s guideline and safety standards such as those published by the National Fire Protection Association NFPA and the American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE and the local code authorities When cutting or drilling into wall or ceiling do not damage electrical wiring and other hidden utilities Ducted fans must always be vented to the outdoors If this unit is to be installed over a tub or shower it must be marked as appropriate for the application NEVER place a switch where it can be reached from a tub or shower FOR BEST RESULTS In a new construction site install the housing during rough in construction of the building The blower assembly light and grille should be installed when the finished ceiling is in place Installation in an existing finished building requires an accessible area attic or crawl space above the planned location See INSTALLATION IN EXISTING CONSTRUCTION am mo INSTALLATION IN A NEW CONSTRUCTION SITE Preparation of Housing Assembly CAUTION When handling the power unit do not reach in the end openings and bend the blower wheels POWER CONNECTOR WING NUT HANGER ROD HANGER ROD FIGURE 1 VERTICAL DISCHARGE ROOF CAP 3 X 10 WALL CAP KNOCKOUTS HORIZONTAL DISCHARGE FIGURE 2 1 Refer to Figure 1 Remove power unit from housing assem