Home

Broan-NuTone N-QT700 Exhaust Fan Exhaust Fan

image

Contents

1. U QuieTTest INSTALLATION INSTRUCTIONS READ amp SAVE THESE INSTRUCTIONS Twin Blower Ventilator MODELS QT 700 amp QT1000 IMPORTANT SAFETY INSTRUCTIONS WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR INJURY TO PERSONS OBSERVE THE FOLLOWING A Use this unit only in the manner intended by the manufacturer If you have questions contact the manufacturer B Before servicing or cleaning unit switch power off at service panel and lock service panel to prevent power from being switched on accidentally When the service disconnecting means cannot be locked securely fasten a prominent warning device such as a tag to the service panel CAUTION For general ventilating use only Do not use to exhaust hazardous or explosive materials and vapors INSTALLATION INSTRUCTIONS WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR INJURY TO PERSONS OBSERVE THE FOLLOWING A Installation work and electrical wiring must be done by qualified person s in accordance with all applicable codes and standards including fire rated construction B Sufficient air is needed for proper combustion and exhausting of gases through the flue chimney of fuel burning equipment to prevent back drafting Follow the heating equipment manufacturer s guideline and safety standards such as those published by the National Fire Protection Association NFPA and the American Society for Heating Refrigeration and Air Condit
2. ce que l ouverture du bo tier soit sur le c t plut t qu la base INSTALLATION AVEC SOLIVES METALLIQES GAINAGE 1 Voir Figure 6 Raccorder le registre a l vacuation Utiliser une bande adh sive pour tous les joints CABLAGE REMARQUE Tous les raccords de c blage doivent respecter les r glements locaux et le ventilateur doit tre convenablement reli la terre 1 Enlever les vis et tre le bo tier de raccordement 2 Amener un c ble de 120v CA avec terre du bo tier de l interrupteur au raccord du bo tier de raccordement en passant par la pr d coupe 3 Voir Figure 7 Raccorder les fils d alimentation aux fils du ventilateur le noir avec le noir le blanc avec le blanc Raccorder le fil de terre la vis de terre verte 4 Replacer le bo tier de raccordement et serrer les vis 5 Reccorder le c ble d alimentation l interrupteur REMARQUE L interrupteur peut tre achet s par ment Voir le catalogue NuTone pour les rensignements comlpets de commande INSTALLATION DU BLOC MOTEUR 1 Replacer le bloc moteur et bien serrer les crous hexagonaux pour un niveau sonore minimum 2 Brancher le ventilateur INSTALLATION DE LA GRILLE Installer la grille en utilisant les vis fournies ENTRETIEN e Couper le courant avant tout nettoyage ou entretien du ventilateur e Si la grille se salit n utiliser qu une solution d eau et de savon doux pour le nettoyage Ne pas utiliser de so
3. tableau de distribution pour viter que le courant ne soit remis accidentellement Lorsque vous ne pouvez verrouiller l interrupteur placez un avertissement clairement visible par exemple une tiquette sur le tableau de distribution ATTENTION Pour ventilation g n rale seulement Ne pas utiliser pour vacuer des vapeurs ou des mati res dangereuses ou explosives DIRECTIVES D INSTALLATION AVERTISSEMENT POUR REDUIRE LES RISQUES D INCENDIE DE CHOC ELECTRIQUE OU DE BLESSURES RESPECTER CE QUI SUIT A Les travaux d installation et d lectricit doivent tre confi s a des personnes qualifi es conform ment aux normes et aux codes en vigueur notamment en ce qui concerne les normes de protection contre les incendies B Pour viter les retours d air les appareils de chauffage doivent avoir suffisamment d air pour assurer une combustion et une vacuation appropri es des gaz Suivre les directives du fabricant de l appareil de chauffage ainsi que les normes de s curit dict es par des organismes comme la National Fire Protection Association NFPA l American Society for Heating INSTRUCTIONS D INSTALLATION LIRE ET CONSERVER CES INSTRUCTIONS 15 46 PO 21 46 PO FIGURE 1 Refrigeration and Air Conditioning Engineers ou les organismes de r glementation locaux C Lorsque vous percez les murs et plafonds viter d endommager les fils lectriques et les autres canalisations D Les ventilateu
4. ANCE OU DU SERVICE Pour conna tre le Centre de service NuTone autoris ind pendant le plus proche R sidents des Etats Unis continentaux composez le num ro sans frais 1 800 543 8687 Garder prot e de la main le num ro du mod le la date et la preuve d achat le type de probleme R sidents de I Alaska et d Hawaii crivez NuTone Inc Attn Department of National Field Service 4820 Red Bank Road Cincinnati Ohio USA 45227 1599 R sidents du Canada crivez Broan Nulone Canada 1140 Tristar Drive Mississauga Ontario Canada L5T 1H9 Rev 03 2001 Product specifications subject to change without notice Les caract ristiques de produits peuvent changer san pr vis U 4820 Red Bank Road Cincinnati Ohio 45227 1140 Tristar Drive Mississauga Ontario Canada L5T 1N2 Printed in U S A Imprim aux E U Rev 04 01 Part No 36468
5. Figure 4 Pr voir un solide cadre de montage pour un niveau sonore le plus bas possible REMARQUE S assurer que le bo tier vienne au ras de la surface du plafond fini 2 Voir Figure 5 Placer le bo tier contre le cadre et reproduire les fentes en forme de trou de serrure des pattes de fixation Fixer le bo tier au cadre en utilisant les vis fournies 3 En fixant le ventilateur bien serrer les vis de montage pour un niveau sonore le plus bas possible AUTRE METHODES DE MONTAGE On peut ajuster ou enlever les pattes de fixation pour divers types d installation Pour adjuster la position des pattes desserrer les Retourner les pattes pour permettre environ 1 po crous hexagonaux de 6 po et d placer les pattes vers d espace suppl mentaire Enlever les crous hexagonaux le haut ou vers le bas Bien resserrer les crous retrourner les pattes et replacer les crous hexagonaux hexagonaux Bien serrer les crous 1 PO MAXIMUM 1 46 PO MINIMUM A LES PATTES DE FIXATION PLACEES DE 2716 PO MAXIMUM CHAQUE COTE DU BOITIER SE REGLENT SELON LES DIFFERENTES EPAISSEURS DE PLAFOND Pour ter les pattes enlever les crous hexagonaux de 6 po Replacer les pattes sur les autres jeux de fentes Replacer les crous hexagonaux et bien serrer ao 12 PO MINIMUM A 13 6 PO MINIMUM 13 PO MAXIMUM A 14 6 PO MAXIMUM Pour une installation en ligne enlever les crous hexagonaux de 6 po Replacer les pattes de mani re a
6. SSES To move brackets remove 6 hex nuts Re position brackets on different set of slots Replace hex nuts and tighten securely ao 12 MINIMUM TO 13 MAXIMUM 13 6 MINIMUM TO 14 6 MAXIMUM For in line installation remove 6 hex nuts Re position brackets so that the housing s opening is at the side instead of the bottom INSTALLATION IN METAL CEILING JOISTS DUCTING 1 Refer to Figure 6 Connect the ductwork to damper duct connector Tape all joints with duct tape WIRING NOTE All wiring connections must comply with local codes ordinances and the National Electric Code and the ventilator must be properly grounded 1 Loosen screws and remove junction box 2 Run 120vAC supply wiring with ground through switch box to Knockout in ventilator housing and secure with box connector 3 Refer to Figure 7 Connect supply wires to ventilator wires black to black white to white Connect ground wire to green ground screw Replace junction box and tighten screws Connect supply wire to switch NOTE Switch must be purchased separately Refer to Nulone s catalog for complete ordering information ors POWER UNIT INSTALLATION 1 Reinstall the power unit and tighten the hex nuts securely to assure minimum sound levels 2 Plug in blower GRILLE INSTALLATION Install the grille using the screws provided MAINTENANCE e Disconnect the power before cleaning or performing any mainte
7. e expresse Certains tats ne reconnaissent pas les restrictions relatives la dur e des garanties implicites il se pourrait donc que cette restriction ne s applique pas dans votre cas LE REMPLACEMENT OU LA R PARATION PAR NUTONE SA PROPRE DISCR TION DE TOUT PRODUIT OU PI CE D FECTUEUX CONSTITUE LE SEUL REM DE DE L ACHETEUR EN VERTU DE CETTE GARANTIE NUTONE NE PEUT TRE TENUE RESPONSABLE DES DOMMAGES INDIRECTS CONS CUTIFS OU SP CIAUX ATTRIBUABLES L UTILISATION OU AU RENDEMENT DU PRODUIT Certains tats ne reconnaissent pas les restrictions ni les exclusions relatives aux dommages indirects cons cutifs ou sp ciaux il se pourrait donc que cette restriction ne s applique pas dans votre cas La pr sente garantie vous accorde des droits sp cifiques mais vous pourriez aussi avoir d autres droits en fonction de l tat dans lequel vous r sidez Cette garantie remplace toute autre garantie donn e pr c demment SERVICE SOUS GARANTIE Pour tre admissible au service sous garantie vous devez a aviser NuTone l adresse fournie ci dessous ou par t l phone au 1 800 543 3687 b fournir le num ro du mod le et la description de la pi ce et c d crire la nature du d faut de la pi ce ou du produit Au moment de la demande de service sous garantie vous devez fournir une preuve de la date d achat originale Date d installation Entrepreneur ou installateur N de mod le et description du produit POUR OBTENIR DE L ASSIST
8. for the express warranty Some states do not allow limitation on how long an implied warranty lasts so the above limitation may not apply to you NUTONE S OBLIGATION TO REPAIR OR REPLACE AT NUTONE S OPTION SHALL BE THE PURCHASER S SOLE AND EXCLUSIVE REMEDY UNDER THIS WARRANTY NUTONE SHALL NOT BE LIABLE FOR INCIDENTAL CONSEQUENTIAL OR SPECIAL DAMAGES ARISING OUT OF OR IN CONNECTION WITH PRODUCT USE OR PERFORMANCE Some states do not allow the exclusion or limitation of incidental or consequential damages so the above limitation or exclusion may not apply to you This warranty gives you specific legal rights and you may also have other rights which vary from state to state This warranty supersedes all prior warranties WARRANTY SERVICE To qualify for warranty service you must a notify NuTone at the address stated below or telephone 1 800 543 8687 b give the model number and part identification and c describe the nature of any defect in the product or part At the time of requesting warranty service you must present evidence of the original purchase date Date of Installation Builder or Installer Model No and Product Description IF YOU NEED ASSISTANCE OR SERVICE For the location of your nearest NuTone Independent Authorized Service Center Residents of the contiguous United States Dial Free 1 800 543 8687 Please be prepared to provide Product model number Date and Proof of purchase The nature of the difficulty Residents of A
9. ioning Engineers ASHRAE and the local code authorities C When cutting or drilling into wall or ceiling do not damage electrical wiring and other hidden utilities D Ducted fans must always be vented to the outdoors E If this unit is to be installed over a tub or shower it must be marked as appropriate for the application F NEVER place a switch where it can be reached from a tub or shower DESCRIPTION Designed for ceiling installation e Refer to Figure 8 Not for use in cooking area e Uses 6 x 19 duct e Suitable for use with solid state speed controls e Do not cover with insulation of a value greater than R 40 e The ventilator consists of the housing mounting brackets junction box power unit olower assembly damper section and grille assembly HOUSING DIMENSIONS FIGURE 1 FOR BEST RESULTS Refer to Figure 1 for dimensions of the housing When installing the ventilator in a new construction site install housing during the rough in construction of the building The power unit and grille should be installed after the finished ceiling is in place To install the ventilator in an existing building an accessible area attic or crawl space is required from above the planned location PREPARATION Unplug the electrical connector from the blower Do not pull on plug wires Remove the power unit from the housing assembly a Remove 9 46 hex nuts holding power unit in place b Pivot the blowe
10. laska or Hawaii should write to NuTone Inc Attn Department of National Field Service 4820 Red Bank Road Cincinnati Ohio 45227 1599 Residents of Canada should write to Broan NuTone Canada 1140 Tristar Drive Mississauga Ontario Canada L5T 1H9 Rev 03 2001 U Garantie limit e d un an GARANTIE DU PROPRI TAIRE NuTone garantie l acheteur original de ses produits que ces derniers seront exempts de tout d faut de mat riaux et de fabrication pour une p riode d un 1 an compter de la date d achat AUCUNE AUTRE GARANTIE IMPLICITE OU EXPRESSE N EST DONNEE Y COMPRIS MAIS SANS S Y LIMITER GARANTIE DE MARCHANDIBILIT OU D ADAPTATION UN USAGE PARTICULIER Pendant cette p riode d un an NuTone proc dera au remplacement ou la r paration sans aucuns frais mais sa propre discr tion de tout produit ou pi ce jug d fectueux dans le cadre d une utilisation normale CETTE GARANTIE NE VISE PAS LES DISPOSITIFS D AMOR AGE NI LES TUBES DES LUMINAIRES FLUORESCENTS Cette garantie ne couvre pas a l entretien et le service courants ni b les produits et les pi ces ayant fait l objet d un usage abusif de n gligence d un accident d un entretien ou d une r paration non appropri e par du personnel non autoris par NuTone d une mauvaise installation ou d une installation non conforme aux directives d installation fournies La dur e de toute garantie implicite est limit e la p riode de deux ans pr cis e pour la garanti
11. lvant ou de nettoyant abrasif INTERRUPTEUR J BOITIER MURAL STANDARD D INTERRUPTEUR COURANT DOMESTIQUE 120vCA 60 Hz FIGURE 7 ESPACE DE CUISSON NE PAS INSTALLER AU DESSUS OU A L INTERIEUR lt lt DE CET ESPACE gt N P N 7 S N 2 N 45 45 7 N 7 7 7 7 Z 7 EQUIPMENT DE CUISSON PLANCHER FIGURE 8 U One Year Limited Warranty WARRANTY OWNER NuTone warrants to the original consumer purchaser of its products that such products will be free from defects in materials or workmanship for a period of one 1 year from the date of original purchase THERE ARE NO OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE During this one year period NuTone will at its option repair or replace without charge any product or part which is found to be defective under normal use and service THIS WARRANTY DOES NOT EXTEND TO FLUORESCENT LAMP STARTERS OR TUBES FILTERS DUCT ROOF CAPS WALL CAPS AND OTHER ACCESSORIES FOR DUCTING This warranty does not cover a normal maintenance and service or b any products or parts which have been subject to misuse negligence accident improper maintenance or repair other than by NuTone faulty installation or installation contrary to recommended installation instructions The duration of any implied warranty is limited to the one year period as specified
12. nance on the ventilator e f the grille becomes dirty use only a mild soap and water solution for cleaning Do not use solvents or abrasive cleaners STANDARD WALL SWITCH 120vVAC 60 Hz HOUSE POWER COOKING AREA N N N SWITCH BOX DO NOT INSTALL ABOVE OR INSIDE N N N N N N 45 THIS AREA COOKING EQUIPMENT gt L H 45 7 Z 7 U Ve nti lateu r Qu iel lest DIMENSIONS DU BOITIER a rotor double MODELES QT 700 amp QT1000 DESCRIPTION e Concu pour installation au plafond e ATTENTION Pour r duire le risque de d charge lectrique couper le courant avant tout entretien e Voir Figure 8 Ne pas utiliser dans les espaces r serv s a la cuisson e Utilise une gaine de 6 po x 19 po e Convient une utilisation avec r gulateur de vitesse semi conducteurs e Ne pas recouvrir d isolant ayant un indice sup rieur a R 40 e Le ventilateur comprend le bo tier les pattes de fixation le bo tier de raccordement l ensemble bloc moteur rotors le registre et la grille IMPORTANTES DIRECTIVES DE S CURIT AVERTISSEMENT POUR R DUIRE LES RISQUES D INCENDIE DE CHOC ELECTRIQUE OU DE BLESSURES RESPECTER CE QUI SUIT Utiliser cet appareil seulement pour les fins pr vues par le fabricant Pour toute question communiquer avec le fabricant B Avant de faire l entretien ou le nettoyage de l appareil couper le courant au
13. r assembly slightly toward the back of the housing and lift straight out c Set the power unit aside DUCTING OPTIONS Refer to Figures 2 and 3 The ventilators may be ducted either horizontally or vertically As illustrated position and secure the damper section to the housing in the desired position VERTICAL DISCHARGE HORIZONTAL DISCHARGE SCREWS 8 SCREWS 8 VENTILATOR UNIT MOUNTING THE HOUSING TYPICAL MOUNTING 1 Refer to Figure 4 Provide a solid mounting frame to assure the lowest possible sound levels NOTE Be certain the housing will be flush with the finished ceiling surface 2 Refer to Figure 5 Position the housing against the frame and trace the mounting bracket s keyhole slots onto the frame Secure the housing to the frame using the screws provided 3 When hanging the unit tighten the mounting screws securely to assure the lowest possible sound levels OPTIONAL MOUNTING METHODS The mounting brackets may be adjusted and or moved for various types of installation Reverse brackets to allow approximately 1 of additional clearance space remove hex nuts flip brackets over and replace hex nuts Tighten nuts securely To adjust bracket position loosen 6 hex nuts and move brackets up or down Re tighten hex nuts securely 1 MAXIMUM 4 46 MINIMUM MOUNTING BRACKETS LOCATED OC TO 2746 MAXIMUM ON EACH SIDE OF THE HOUSING ARE ADJUSTABLE TO ALLOW FOR VARIOUS CEILING THICKNE
14. rs dot s de tuyau doivent toujours tre raccord s l ext rieur E Si cet appareil doit tre install au dessus d un bain ou d une cabine de douche il doit tre identifi comme convenant une telle installation F NE JAMAIS placer un interrupteur la port e d une personne qui se trouverait dans le bain ou la douche POUR DE MEILLEURS RESULTATS Voir Figure 1 pour les dimensions du bo tier Lorsqu on installe le ventilateur dans une construction neuve installe le bo tier avant de proc der aux finitions Le bloc moteur et la grille doivent tre install s apr s le finition du plafond Pour installer le ventilateur dans une construction ancienne un espace accessible au dessus de l emplacement choisi pour l installation est exig qrenier ou combles PREPARATION D brancher le raccord lectrique du ventilateur Ne pas tirer sur les fils Enlever le bloc moteur du boitier a Enlever les crous hexagonaux de 6 po retenant le bloc moteur b Faire pivoter l g rement le bloc moteur vers l arri re du bo tier et soulever verticalement c Mettre le bloc moteur de c t OPTIONS D EVACUATION Voir Figures 2 et 3 Les ventilateurs sont pr vus pour evacuation horizontale ou verticale Placer et fixer le registre au boitier en position voulue comme illustr EVACUATION VERTICALE EVACUATION HORIZONTALE VIS 8 VIS 8 VENTILATEUR MONTAGE DU BOITIER MONTAGE TYPE 1 Voir

Download Pdf Manuals

image

Related Search

Related Contents

WS400 Wastewater Sampler User Manual  ELSA Computer Monitor 530 User's Manual  Opticon CRD1006  User Manual  HOJA DE DATOS DE SEGURIDAD  Manual do Utilizador do Nokia E70  Polycom CX 700 User Guide  Wilo-NL  Philips In-Ear Headphones SHE9551  StarTech.com 3 ft HD15 to Component RCA Breakout Cable Adapter - M/M  