Contents
1. 44 BEFORE YOU BEGIN PACKAGE CONTENTS CHECK THIS PACKING LIST BEFORE YOU BEGIN IF SOME PARTS ARE MISSING CONTACT YOUR DEALER OR A MINOLTA SERVICE FACILITY e Minolta Dim ge Scan Multi scanner e 35mm Film Holder FH M1 e 35mm Slide Mount Holder SH M1 e Medium Format Film Holder MH M1 Film Masks 6 x 4 5 Medium Format Film Mask 6 x 6 Medium Format Film Mask 6 x 7 Medium Format Film Mask 6 x 8 Medium Format Film Mask 6 x 9 Medium Format Film Mask APS Sleeve Film Mask 16mm Film Mask Power Cord PW M2 e SCSI Cable SC 11 e Dim ge Scan Multi CD ROM v1 0 Instruction Manuals 1 software 1 hardware e Warranty and Software Registration card Fluorescent lamp unit cover Connector cover Indicator lamp Eject button Accessory panel Film slot door Power lamp Power switch AC socket SCSI ID switch Centronics Terminator dip switch D sub 25 port UNLOCK THE OPTICS BEFORE USING THE SCANNER FOR THE FIRST TIME The optics inside the scanner have been parked and locked before shipment for their protection Before using the scanner for the first time unlock the locking pin e Gently turn the scanner up side down Using a flat head screwdriver turn the locking pin counter clockwise until it pops up SETTING THE SCSI ID The Dim ge Scan Multi s SCSI ID is factory preset to 5 If 5 is not being used by another operating SCSI device in the SCSI chain it is not neces
2. LAUNCHING THE SOFTWARE WINDOWS The utility software is a stand alone application used to control the scanner The TWAIN driver lets you control the software through another application such as your image editing software LAUNCHING THE TWAIN DRIVER This uses Adobe Photoshop 4 0 1 as the example Commands may vary among applications E Adobe Photoshop 1 Open the host application Select Filter View Window Help Edit lmage Layer 2 Select File Import Select PUR TWAIN 32 Source Open The Select Source dialog box appears penes CHES Save As Shieh es Save d Altera Revert Bacen Import Export Quick E dit Select TWAIN Sourc leina Bage SAECH TWAIN 32 Select Source 3 Select DS Multi 1 0 then click on Select EIN 4 Select File Import TWAIN 32 Hever e The start up screen will briefly appear The Place software is ready for use when the Command window appears E Quick E dit 2 Select TWAIN Source Select TWAIN 32 Source Bin LAUNCHING THE UTILITY SOFTWARE Select Start Programs Minolta Dim ge Scan Multi DS Multi Utility Es start up screen will briefly 23 Adobe appear The softwar
3. Please read and understand each caution before using this product N CAUTION To avoid fire or electric shock Only use the voltage specified for this unit Do not expose this unit to liquids Do not insert metal objects into this unit Do not touch the cord or plug if your hands are wet Unplug this unit when it is not in use Improper use of the power cord may result in fire or electric shock Insert the plug securely into an electrical outlet Do not pull on the cord Grasp the plug when removing the power cord from an outlet Do not scratch twist modify heat or place heavy object on the power cord Do not connect the ground to a gas pipe telephone ground or a water pipe Improper grounding can result in electric shock This product must have sufficient ventilation while in use Blocked ventilation ducts may cause the unit to overheat increasing the risk of fire Do not use or store this product in dusty or very humid areas If there is smoke a strange smell or any other unusual conditions shut down and unplug the unit then contact a Minolta Service Facility Do not attempt to disassemble this product It contains high voltage circuits Take the product to a Minolta Service facility for repairs Unexpected damage may occur if this unit is left unattended near young children TABLE OF 5 FOR PROPER AND SAFE USE 1 BEFORE YOU BEGIN Package sosta ro d
4. MINSLIA Dimage Scan Hardware Manual Thank you for purchasing the Minolta Dim ge Scan Multi The Dim ge Scan Multi is a multiple format film scanner capable of scanning medium format 35mm 16mm and sleeved APS film With the optional APS adapter advanced photo system film in the cassette can also be scanned Your new scanner has extraordinary features including Medium format film scanning capability The included medium format film holder uses antinewton glass and includes masks for 6x4 5 6x6 6x7 6x9 12 bit AD converter so fine detail is captured with a dynamic range This manual has been designed to help you understand the operation of your scanner To realize all the benefits of your scanner please read this manual and the accompanying software manual thoroughly The instructions in this manual assume you have a working knowledge of the operating system for your computer Mac OS Windows 95 or Windows NT and its conventions Familiarity with the mouse and standard operating system menus and commands is necessary before operating the Dim ge Scan Multi software This manual does not instruct in the basic use of personal computers use of Window 95 Windows NT or Mac OS use of Adobe Photoshop Paint Shop Pro or Corel Draw Microsoft Windows amp Windows 950 and Windows are registered trademarks of the Microsoft Corporation Macintosh Apple and Power Macintosh are registered t
5. Adapters icon Confirm that Minolta 2883 appears as a connected device for your SCSI board Minolta 22883 does not appear turn the system off and check all the connections Repeat the procedure 4 Insert the Dim ge Scan Multi CD ROM into the CD ROM drive 5 From the START button select RUN The Run dialog box will appear 36 6 Select D European ENGLISH Setup exe from the Open drop down list then click on OK e If your CD ROM drive is not the D drive replace the D with the appropriate letter for your CD ROM drive The Software License Agreement will appear T After reading the agreement click on Yes The Choose Destination Location dialog box will appear 8 To select another destination directory click on Browse and select the directory Click on Next The Setup Type dialog box will appear 9 Choose either Typical or Twain Files Only install then click on Next The Select Program Folder dialog box will appear 37 Run D European ENGLISH setup exe x OK Cancel Browse Type the name of a program folder or document and Windows will open itfor you Software License Agreement x IPAREFULLY READ THE LICENSE AGREEMENT BELOW BEFORE OPENING THIS PACKAGED SOFTWARE OPENING THIS PACKAGE INDICATES YOUR ACCEPTANCE TO THE TERMS AND CONDITION BELOW IF YOU DO NOT AGREE WITH THEM YOU SHOULD PROMPTLY RETURN ITHE PACKAGE UNOPENED This
6. HOLDER 1 Use the 1 for 120 220 film frames in 6x4 5 6x6 6x7 and 6x9 formats The MH M1 should also be used for sleeved APS film 16mm film and film Use the appropriate film mask for each film format The glass in the Medium Format Film Holder MH M1 has been treated to prevent the appearance of Newton s rings colored rings when scanning Handle the Medium Format Film Holder 1 with care Protect the glass from impact shock and scratches Touching the glass in the film holder may cause damage to the antinewton treatment Blow away any dust from the film holder before inserting the film If the film holder is dirty first blow away any dust or debris then moisten a lens cleaning tissue with lens cleaning fluid and gently wipe the surface Transmission Electron Microscope MEDIUM FORMAT AND TEM FILM 1 Press the lever marked PUSH then lift open the holder 2 Select the appropriate mask and place it in the film holder using the guides The cut corner on the mask should be on the bottom left side Choose the appropriate size mask for TEM film Align the slot in the mask with the rail on the film holder Align the holes in the mask with the pins on the film holder 3 Place the film in the film holder Secure the film by placing it flush against the rail on the film holder Place the film e
7. film with the VEI set to can be inserted into the APS Adapter AD 100 APS ADAPTER NAMES OF PARTS Film chamber release Film chamber door SETS Scanner contacts Do not touch 24 LOADING THE CASSETTE 1 Slide the film chamber release as shown The film chamber door will open 2 Insert the film cassette into the film chamber with the VEI on top Only load cassettes displaying the mark 3 Close the film chamber door The film chamber release will return to its start position when the door is closed properly 28 Y 25 INSERTING THE ADAPTER 26 1 Press the power switch to turn the scanner on Turn on your computer then launch the Dim ge Scan Multi software The green indicator lamp will blink slowly while the scanner is setting up 2 Pull the accessory panel on the scanner straight out then open it all the way pushing it until it clicks Do not force the accessory panel Do not open the accessory panel during the set up process Wait until set up is complete and the indicator lamp is off 3 Insert the holder into the scanner in the direction indicated by the white arrow on top of the adapter Do not insert the adapter at an angle 4 Gently push the adapter into the scanner until the raised insertion mark 4 is aligned with the film slot door The adapter wi
8. for most users C TWAINFiles Only TWAIN Data Sources installed Space Required 3624K Space Available 419392 Back Cancel INSTALLING THE SOFTWARE 10 Click on Next Setup will begin When setup is complete a message will appear informing you installation was successful 11 Click on Close A message will appear asking if you want to restart the computer 12 Click on Yes Select Program Folder x Setup will add program icons to the Program Folder listed below You may type anew folder name or select one from the Existing Folders list Click Next to continue Program Folder Minolta Dimage Scan Multi Existing Folders Accessories Adobe MGA PowerDesk Minolta QuickScan 35 RD 175 StartUp wen Setup is complete and Minolta Dimage Scan Multi 1 0 is now installed Setup is complete Please read Readme file Minolta Dimage Scan Multi 1 0 Setup You must shut down and restart your computer before the new settings will take effect Do you want to restart your computer now The Dimage Scan Multi setup will have placed the following files on your computer ds multi exe Readme txt Job twain dll twain32 dll twunk_16 exe twunk_32 exe dsm tw ini Dsmulti hlp Dsmultij hlp ds_multi dll dsm resj dll DS multi ds 38 INSTALLING THE SOFTWARE MACINTOSH 1 Insert the Dim ge Scan Mu
9. icon The start up screen will briefly appear The software is ready for use when the Command window appears 8 File Edit View Label Special 9 09 PM My Computer 21 items 286 6 MB in disk 322 4 MB available System Folder About Mac OS 7 6 Adobe Photoshop 3 0 DS Multi 2 items 286 6 MB in disk 522 4 MB available 43
10. is a license agreement and not an agreement for sale Minolta owns or has been licensed from other owners copyrights in the computer programs Software You obtain no rights to the intellectual property in the Software other than the license granted to you regarding the Software under this agreement The title to the enclosed copy ofthe copy the Software and any copy made from itis retained by Minolta or such other owners 1 LICENSE You may 1 install and use the Software on only one computer at any one time Please read the following License Agreement Press the PAGE DOWN key to see the rest of the agreement Do you accept all the terms of the preceding License Agreement If you choose No Setup will close To install this product you must accept this agreement Print Choose Destination Location Setup will install Minolta Dimage Scan Multi in the following directory To install to this directory click Next To install to a different directory click Browse and select another directory You can choose notto install Minolta Dimage Scan Multi by clicking Cancel to exit Setup C PROGRAM FILES DS_MULTI Browse 3624K Space Required 419400 K Cancel Space Available lt Back Setup Type Clickthe type of Setup you prefer then click Next Typical Program will be installed with the most common options Recommended
11. the CD ROM drive then double click on the Dim ge Scan Multi icon The language folders will appear 2 Double click on the English folder to open it then double click on the ColorSync folder 3 Drag the ColorSync system extension to the Extensions folder 4 Drag the ColorSync System Profile to the Control Panels folder 5 Drag the ColorSync System Profiles folder to the Preferences folder 6 Drag the DS Multi Profiles into the ColorSync System Profile folder now in the Preferences folder 7 Drag the ColorSync filter to Adobe Photoshop s Filters folder located inside the Plug ins folder File Edit Label Special File Edit View Label Special English ColorSync English System Folder System Folder Colorsync 414 9 indisk 105 2 MB available aa MBd disi 417 1 MB in disk fa 5 items 331 1 MB in disk Preferences ColorSync ColorSyne Filter 417 1 MB in disk il ls LE ColorSync System Profile Extensions ColorSync ColorSync Filter 1 Acrobat Reader Prefs Extensions Manager Prefs 3 Startup It Control Panels ColorSyne System Profile Preferences ColorSync Profiles ColorSync Profiles B Sound Preferences ColorSync Profiles e F4 5 amp DS Multi Profile 5 Apple Menu Items 5 9 Z B
12. 0 SOLD 24 APS Adapter Names of Paris ite esso bti 24 Loading the 5 EE 25 Inserting the oon pedit ento uA A im 26 Ejecting the 27 CHANGING THE FLUORESCENT 28 IMPORTANT BEFORE TRANSPORTING THE SCANNER 30 TROUBLESHOOTINGS 2 He te re HE tonus 31 SN I 33 DETAILS ise han et t 34 CUSTOMER SERVICE ertt EE reis tte dabo 35 INSTALLING THE SOFTWARE Windows 95 Windows INT nente Mita oe etie 36 A rs ou sd 39 de mo Sant buio o ae vtta cca 40 Macintosh GolorSyme M2 eerie es veered repe tee rt tere ot pente c Spe Hope Eee 41 LAUNCHING THE SOFTWARE WINDOWS Launching the TWAINUDEINGE ion te ior aie qu recibe bo 42 Launching the Utility 42 LAUNCHING THE SOFTWARE MACINTOSH lute s E p Emm 43 Launching the Utility 43 MINOLTA
13. OPENED This is license agreement and not an agreement for sale Minolta owns or has been licensed from other owners copyrights in the computer programs Software You obtain no rights to the intellectual property in the Software other than the license granted to you regarding the Software under this agreement The title to the enclosed copy of the copy the Software and any copy made from it is retained by Minolta or such other owners 1 LICENSE 5 DS Multi Installer Easy Install Installs both DS Multi Utility and DS Multi Plug in This option is recommended for all users r Install Location 7600 v onthe disk PowerPC Drive Installation was successful If you are finished click Quit to leave the Installer If you wish to perform additional installations click Continue MACINTOSH PLUG IN Once the installation procedure is complete move the DS Multi Plug in from the Dim ge Scan Multi folder to the appropriate folder for the host application Adobe Photoshop 3 0 5 Open Photoshop s Plug ins folder then drag and drop the DS Multi Plug in into the Plug ins Acquire Export folder Adobe Photoshop 4 0 1 Open Photoshop s Plug ins folder then drag and drop the DS Multi Plug in into the Plug ins Import Export folder 8 File Edit Label Special 7 05 PM 2 DS Multi 284 9 MB indisk 324 1 MB availa
14. ble Adobe Photoshop 3 0 284 9 MB in disk 324 1 MB available Power PC HD Adobe Photoshop 3 0 3 DS Multi Utility Goodies Plug ins 9 MB in disk 324 1 MB available nti aliased PICT aths to lllustrat Edit LE es DS Dual Plug in 9535 Plug in 2 5 n GIF893 Export 40 MACINTOSH COLORSYNC 2 0 ColorSync helps your colour devices monitor scanner printer etc match their colours This makes it faster and easier to obtain the correct colours in the final image The Dimage Scan Multi driver software is compatible with ColorSync 2 0 which is included with the software If ColorSync 1 0 is already installed on your computer please remove it before installing ColorSync 2 0 Removing ColorSync 1 0 To remove ColorSync 1 0 from your system drag the following items into the trash ColorSync system extension from the Extensions folder ColorSync System Profile control panel from the Control Panels folder ColorSync Profiles folder from the Preferences folder Installing ColorSync 2 0 The included ColorSync software can be installed directly from the Dim ge Scan Multi CD ROM For Mac OS 7 5 and 7 5 2 or later follow steps 1 2 6 and 7 only If using Adobe Photoshop 4 0 or higher in any Mac OS do not perform step 7 1 Insert the Dim ge Scan Multi CD ROM into
15. cking position through the software the scanner must perform the set up operation to return to normal The scanner automatically performs set up when it is first turned on Set up can also be initiated by pressing the following keys simultaneously while the software is active Windows95 NT Control Shift i Macintosh Command Shift i 30 TROUBLESHOOTING Symptom Cause Action Reference The computer will not start after connecting Check that all the SCSI cables are secure Page 8 the scanner Check that two SCSI devices are not sharing the same address The computer does not recognize the Was the scanner turned on before the scanner computer was turned on Check that all the SCSI cables are secure Windows 95 NT Check that the SCSI device driver been installed correctly 1 Select Start Settings Control Panel The Control Panel window will appear 2 Double click on the System Icon then click on the Device Manager tab 3 Click on the plus next to SCSI controllers A sub menu of SCSI controllers should appear 4 Confirm the appropriate SCSI Controller for your board is listed in the sub menu a Other devices H ay Ports COM amp LPT 4 Adaptec AHA 2940 AHA 2940 W PCI SCSI Controller H n Sound video and game controllers The scanner does not pull in the film holder Eject then reinsert the holder hen loadi whenloaaing The film holder must be inserted to th
16. e 4 marks for it to be engaged by the scanner s motor The scanned image is very green or blown The mask does not fit the image properly Be Pages 18 21 out white when using the Medium format sure to use a proper fitting mask that is not too holder big for the image There should be no uncovered space between the film and the mask The indicator lamp glows red If using a film holder The accessory panel is open Close the accessory panel If using the APS adapter Page 26 The accessory panel is not fully open Open it all the way and push it until it clicks 31 Continued on following page TROUBLESHOOTING Symptom The indicator lamp is red and blinks rapidly The scanned image is black Cause Action 1 Turn off the computer then the scanner Check that the fluorescent lamp cover is closed 2 Turn on the scanner If the fluorescent lamp does not glow replace the lamp 3 If the cover was closed the fluorescent lamp works and the red lamp continues to blink rapidly there is a hardware problem Turn off and unplug the scanner then call a Minolta Service Facility Reference Page 28 The scanned image color is strange Check that there is no dust on the film or film holder Check that the color palette START SETTINGS CONTROL PANEL DISPLAY SETTINGS is on High Color 16 bit or higher Different or additional steps may be necessary dependin
17. e is ready for use when the Command Find window appears s 9 175 gj StartUp Bun MS DOS Prompt Accessories PowerDesk Minolta Dima 19 Minolta QuickScan 35 2 QJ Windows Explorer Multi Dimage Scan Multi v1 0 Read Me is DS Multi Utility Remove Minolta Dimage Scan Multi 42 LAUNCHING THE SOFTWARE MACINTOSH The utility software is a stand alone application used to control the scanner The plug in lets you control the software through Adobe Photoshop LAUNCHING THE PLUG IN 1 Launch Adobe Photoshop 2 Photoshop 3 0 5 Select File Acquire DS Multi plug in ver 1 0 Photoshop 4 0 1 Select File Import DS Multi plug in ver 1 0 3 The start up screen will briefly appear The software is ready for use when the Edit Mode Image Filter Select Window Command window appears Open Place Close Save Save fis Save a Copy Revert Acquire Anti aliased PICT DS Multi Plug in ver 1 0 File Info PICT Resource 0555 Plug in v2 5E 5 Quick Edit Print TIFF with ColorSync Profile TWAIN Acquire Preferences gt TWAIN Select Source Quit LAUNCHING THE UTILITY SOFTWARE 1 the DS Multi folder This folder will be in the location selected during installation 2 Double click on the DS Multi Utility
18. essory panel is open Close the accessory panel If using the APS adapter The accessory panel is not fully open Open it all the way and push it until it clicks Red blinks quickly The fluorescent lamp unit cover is not fully closed or The fluorescent lamp is burnt out or There is a hardware malfunction Contact a Minolta Service facility 33 CUSTOMER SERVICE Please contact your dealer regarding installation SCSI interface recommendations or application compatibility If your dealer is unable to help you contact us toll free Technical Support 1 800 808 4888 Monday Friday 8 30 5 00 EST Minolta Corporation 101 Williams Dr Ramsey NJ 07446 201 825 4000 http www minolta com http www minolta de europe Please have the following information ready when calling Minolta Technical Support Make and model of your computer Available application RAM Operating system and version Other connected SCSI devices and their SCSI ID numbers DS Multi software version number Symptoms Messages that appear on the screen when the problem occurs Frequency of occurrence To determine the version number of your driver software Place the pointer over the Status Bar in the Command window The version number will be displayed in the status window 35 INSTALLING THE SOFTWARE WINDOWS 95 WINDOWS NT nm These installation instructi
19. g on your graphics board Refer to your graphics board s documentation If using the Medium format holder be sure to use a proper fitting mask If the holder is dirty clean it as directed Reinitialize the scanner Windows 95 NT Press Control Shift and i keys simultaneously Macintosh Press Command Shift and i keys simultaneously Reinitializing while using the APS adapter 1 Press the initialization key combination 2 The adapter will eject automatically 3 Initialization set up will stop 4 Remove the adapter 5 Close the accessory panel Initialization set up will resume 32 INDICATOR LAMP The indicator lamp on the front of the scanner reveals the status of the scanner Indicator Lamp Scanner Status Off Set up is complete and there is no holder inserted in the scanner Green blinking slowly Scanner is busy setting up initializing index scanning prescanning or scanning autofocus point AF manual focus Green blinking quickly If using a film holder the scanner is busy loading the film holder transporting the film holder ejecting the film holder If using the APS Adapter the scanner is busy rewinding the film in the APS adapter transporting the adapter Green glows steadily There is a film holder in the scanner The scanner is not busy Red glows steadily There is a problem with the accessory panel If using a film holder The acc
20. ll be automatically guided in past the mark If the adapter is not loaded correctly then eject and reinsert it EJECTING THE ADAPTER 1 Press the eject button on the front of the scanner The adapter will automatically eject partway then stop 2 Remove the adapter Wait for the Indicator lamp to turn off before removing the adapter The adapter should pull out easily When the Eject button on the front of the scanner is used the film will rewind into the cassette before the adapter is ejected regardless of the software Preference settings Please refer to the Preferences section in the software manual e f a film transport error occurs do not use that cassette in the adapter Contact a Minolta Service Facility Minolta is not responsible for damage to the cassette With some camera models the images will appear up side down Use the Rotate All Frames 180 option in the Preferences Please refer to the Preferences section in the software manual 27 CHANGING THE FLUORESCENT LAMP When the indicator light is red and blinks rapidly check to see of the fluorescent lamp is operational Replace the fluorescent lamp when it burns out See your dealer to purchase a replacement lamp unit CAUTION Turn off the scanner and allow the unit to cool for 10 minutes before removing the fluorescent lamp 1 Remove the fluorescent lamp unit cover 2 Pu
21. ll up the locking bar 3 Press on the release tab on the plug and disconnect the old lamp 28 4 Connect the new lamp Snap the connectors together until they click 5 Place the lamp unit in the scanner by aligning the raised edge of the lamp unit 1 with the rectangular notch 2 on the scanner The arrows on the lamp and scanner should be lined up The lamp unit will not slide from side to side if itis inserted correctly 6 Hold the lamp unit in place and replace the locking bar 7 the fluorescent lamp unit cover 29 IMPORTANT BEFORE TRANSPORTING THE SCANNER Before transporting the scanner the optics must be parked and locked into place to prevent damage 1 With the Dim ge Scan Multi software active utility TWAIN driver or plug in Windows press Ctrl Shift Macintosh press Command Shift 2 The message informing you the optics will be moved will appear Click on OK 3 After the optics have been moved a message will appear asking you to turn the scanner off Click on OK The utility software will quit 4 Turn off the computer 5 Turn off the scanner and other SCSI devices 6 Gently turn the scanner up side down Using a flat head screwdriver push down and turn the locking pin clockwise until it locks down Once the optics have been moved to the lo
22. loosen it 2 Rotate the carrier as desired Use the angle scale on the holder for reference With larger film formats the corners of the frame may not fit in the scanning area when the carrier is rotated 3 Turn the holding screw clockwise to secure it 22 INSERTING THE HOLDER INTO THE SCANNER EJECTING 1 Press the power switch to turn the scanner on Turn on your computer then launch the Dim ge Scan Multi software The green indicator lamp will blink slowly while the scanner is setting up 2 Insert the holder into the scanner in the direction indicated by the white arrow on top of the holder Do not insert the holder at an angle 3 Gently push the holder into the scanner until the raised insertion mark I is aligned with the film slot door The film holder will be automatically guided in past the I mark f the holder is not loaded correctly then eject and reinsert it 23 1 Press the eject button on the front of the scanner The holder will automatically eject partway then stop 2 Remove the holder Wait for the Indicator lamp to turn off before removing the holder The holder should pull out easily APS ADAPTER AD 100 SOLD SEPARATELY The APS Adapter AD 100 optional accessory is required to scan APS film in the cassette with the Dim ge Scan Multi Only processed
23. lti CD ROM into the CD ROM drive The Dim ge Scan Multi CD ROM icon will appear on the desktop 8 File Edit Label Special B a 2 Double click on the Dim ge Scan Multi CD ROM icon The language folders will appear 3 Double click on the European English pimage Scan Multi language folder 85 items 13 5 MB in disk The Dim ge Scan Multi Installer icon will appear 4 Double click on the Dim ge Scan Multi Installer icon 2 items 331 1 MB in disk zero K available m The installer screen will appear ColorSunc DS Multi Installer 5 Click on Continue The User License Agreement will appear This installation was created with Installer VISE 4 6 1 from MindVision Software 39 Continued on next page 6 Click on Accept The Dim ge Scan Multi Installer will appear 7 Choose the Install Type and confirm the Install Location of the software then click on Install Installation will begin When installation is complete a message will appear informing you installation was successful 8 Click on Quit The software will be installed in a new folder titled Dim ge Scan Multi e If Easy Install was chosen the Dim ge Scan Multi folder will contain the following items the DS Multi Utility DS Multi Plug in and Read Me file ACCEPTANCE TO THE TERMS AND CONDITION BELOW IF YOU DO NOT AGREE WITH THEM YOU SHOULD PROMPTLY RETURN THE PACKAGE UN
24. mulsion side down p 14 Secure the film by placing it flush against the rail on the film holder 4 Press the cover firmly closed until it clicks ways use proper fitting mask with medium format holder f no 99 is mask that 15 too on wil used refracting Ber 19 Align the slot in the mask with the rail on the film holder Align the holes in the mask with the pins on the film holder 20 1 Press on the lever marked PUSH then lift open the holder 2 Place the APS Sleeve mask or 16mm mask on the film holder The film guides on the mask should be on the right side Make sure the film lies flat between the 3 Place the film in the mask film guides using the film guides Place the film emulsion side down p 14 O PUSH Make sure the film lies flat between the film guides 4 Align the desired frame within the scanning window PUSH 5 Press the cover firmly closed until it clicks qu ality ROTATING THE FRAME The image area of the Medium Format Holder MH M1 can rotate 10 degrees in either direction to compensate for a tilted image composition By rotating the frame before scanning the need to rotate the scanned image thus resampling the pixels is eliminated 1 Turn the holding screw counter clockwise to
25. on Vio ED oo Od HR cb D an s Ue ME V CEA AU Ere Cela eo 4 System 5 NAMES OF PARTS OM s cab 6 LINER T OESTE SPURS 7 Important Locking Pin Informiatioli uos ue nae oe Rc Aes orti taedas 7 GB on Dp UD DoD OG vag bon Qf 8 CONNECTING TO THE COMPUTER If the Scanner is the Only or Last Device in the 9 If the Scanner is Inside the Chal oen retra n eae uo 11 GETTING STARTED 14 Gal oth RES 14 LOADING 35MM FILM HOLDERS Slide Mount Holder 1 15 35mm Film Holder oiii ho ode fo uana 16 LOADING THE MEDIUM FORMAT FILM HOLDER MH M1 Using the Medium Format Film Holder 1 18 Medium Format and TEM TI 28 ecole oo ete n iret tbid 18 16mm and APS Sleeve 20 Rotating FIAMIG csi oat nie poaait epe rae to de ucc rb Eta 22 INSERTING THE HOLDER INTO THE 5 23 PONERTE TECH 23 APS ADAPTER AD 10
26. on assume drive D is the CD ROM drive 1 Turn on the Dim ge Scan Multi then turn on your PC 2 Start Windows 95 or Windows NT 3 This step varies with your specific operating software Windows 95 The New Hardware Found dialog box will appear New Hardware Found 9 Unknown Device Select which driver you want to install for your new hardware Driver from disk provided by hardware manufacturer C Do not install a driver Windows will not prompt you again Sel 3 Click on Cancel This dialog box may appear several times Repeat step 3 until the dialog box no longer appears Windows NT Windows 95 Release 2 OSR2 The appearance and or wording of some dialog boxes may vary The following dialog box will appear Update Device Driver Wizard This wizard will complete the installation of Unknown Device by searching your local drives network and Internet locations for the most current driver If you have a disk or CD ROM that came with this device insert it now It is recommended that you let Windows search for an updated driver To do this click Next to continue Cancel 3a Click on Next A similar dialog box will appear 3b Click on Finish This dialog box may appear several times Repeat step 3 until the dialog box no longer appears 3 Select START SETTINGS CONTROL PANEL then double click on the SCSI
27. ount holder can hold up to 4 mounted slides 85mm or APS Slide mounts must be thicker than 1mm and thinner than 2mm to fit properly into the holder Results of scanning glass mounted slides can be unpredictable Blow dust off the slide before placing it into the film holder 1 Position the slide mount holder so the white arrow is on the top left side then open the slide mount Open the slide holder by pushing up on the two tabs from underneath 2 Place the slides within the indentations making sure they lie flat Insert the slides emulsion side down 3 Press the cover firmly closed until it clicks 35MM FILM HOLDER 1 Use the FH M1 for 35mm negatives and unmounted 35mm slide film The 35mm Film Holder FH M1 can hold film strips up to 6 frames long Blow dust off the film before placing it into the film holder Position the film holder so the white arrow is on the top left side then open the slide mount Open the slide holder by pushing up on the two tabs from underneath 2 Place the film in the film holder emulsion side down 3 Align the frames within the scanning windows 4 Press the cover firmly closed until it clicks LOADING THE MEDIUM FORMAT HOLDER 1 USING THE MEDIUM FORMAT
28. rademarks of Apple Computer Inc Other corporate and product names are the trademarks and registered trademarks of their respective companies Changes or modifications not approved by the party responsible for compliance could void the user s authority to operate the equipment This manual may not be copied in part or whole without prior written permission from Minolta Co Ltd 1998 Minolta Co Ltd Every necessary caution has been taken to ensure the accuracy of this instruction manual Please contact us if you have any questions find any errors or notice missing information Minolta is not responsible for loss damage or other results occurring during the operation of this product This mark certifies that this product meets the requirements of the EU European Union concerning interference causing equipment regulations CE stands for Conformit Europ enne Film Scanner Dimage Scan Multi This device complies with Part 15 of the FCC Rules Operation is subject to the following conditions 1 This device may not cause harmful interference and 2 this device must C 22 accept any interference received including interference that may cause undesired Operation FOR HOME OR OFFICE USE not remove the ferrite cores from the SCSI cable This Class B digital apparatus complies with Canadian ICES 0003 Cet appareil num rique de la classe B est conforme la norm NMB 003 du Canada FOR PROPER AND SAFE USE
29. rt can be used there is no dedicated in or out port 2 Connect the other end of the SCSI cable to the SCSI port on the computer or on the last SCSI device in the chain 3 Flip the dip switch marked 1 up to turn the terminator on Dip switches 2 through 4 are inactive Their position will not affect the scanner operation 9 Continued on following page 4 Plug the power cord into scanner s AC socket 5 Plug the other end of the power cord into a grounded outlet IF THE SCANNER IS INSIDE THE CHAIN TURN OFF THE COMPUTER AND ALL THE SCSI DEVICES BEFORE CHANGING SCSI IDS CONNECTING SCSI CABLES OR DISCONNECTING SCSI CABLES P One D sub 25 to Centronics 50 cable is included with your scanner Please see your dealer if you require additional cables The following is an example of one possible SCSI chain configuration Computer SCSI Device 1 SCSI Device 2 Scanner 1 Connect one end of the SCSI cable A into either SCSI port on the back of the scanner Either SCSI port can be used there is no dedicated in or out port UL 2 Plug the other end of SCSI cable into SCSI device 1 11 Continued on following page CONNECTING TO THE COMPUTER 3 Connect one end of SCSI cable B into the remaining SCSI port on the back of the scanner 4 Connect the other end of SCSI cable B into the ne
30. sary to change the SCSI ID A SCSI ID is a unique address you assign to each SCSI device connected to your computer The SCSI ID range of your computer is from 0 to 7 however some IDs are already occupied by your computer Occupied SCSI ID IBM PC AT 7 SCSI host adapter Macintosh 0 internal hard drive 3 internal CD ROM drive 7 system IDE Macintosh systems do not use SCSI ID 0 for the hard drive Macintosh systems with a dual bus have SCSI ID 3 available on the external bus TURN OFF THE COMPUTER AND ALL THE SCSI DEVICES BEFORE CHANGING SCSI IDS CONNECTING SCSI CABLES OR DISCONNECTING SCSI CABLES TO CHANGE THE SGSI ID 1 Turn off the computer and all connected SCSI devices 2 Determine which SCSI IDs are not being used 3 Change the SCSI ID using the upper or lower SCSI buttons Press the upper button to select a smaller SCSI number The current SCSI ID number Press the lower button to select a higher SCSI number CONNECTING TO THE COMPUTER IF THE SCANNER IS THE ONLY OR LAST DEVICE IN THE CHAIN BEFORE CHANGING SCSI IDS CONNECTING SCSI TURN OFF THE COMPUTER AND ALL THE SCSI DEVICES CABLES OR DISCONNECTING SCSI CABLES One D sub 25 to Centronics 50 cable is included with your scanner Please see your dealer if you require a different cable 1 Connect one end of the SCSI cable to either SCSI port on the back of the scanner Either SCSI po
31. xt device in the chain 5 Flip the dip switch marked 1 down to turn the terminator off Dip switches 2 through 4 are inactive Their position will not affect the scanner operation 6 Plug the power cord into the scanner s AC socket 7 Plug the other end of the power cord into a grounded outlet RR NOTE th of scsi chain cable in A should no 20 ft for most systems 13 GETTING STARTED FILM EMULSION The emulsion side of the film is the side coated with the photographic material The base side of the film has no photographic material and its surface is smooth and shiny The emulsion side of slide film has raised areas at subject contrast The emulsion side of negative film is dull compared to the base side It is easiest to determine the emulsion side when viewing the film at an angle Light Viewing angle lt FILM EMULSION Slightly dull or raised surface lt FILM BASE Smooth shiny surface The frame numbers and text are backward when the film s emulsion side is up HANDLING CARE Do not pull the film holder out of the scanner until the holder is properly ejected and the green indicator light is off Do not move the scanner or touch film holder while the transport motor is engaged such as while scanning Place the scanner a stable surface 14 LOADING 35MM FILM HOLDERS SLIDE MOUNT HOLDER SH M1 slide m