Home
Soleus MAC-12K Air Conditioner
Contents
1. the unit is running on heating mode the exhaust duct is inoperative and is not required 5 Auto Operation a Install the exhaust ducts properly b Plug the Power Cord to the power outlet c Turn on the unit by pressing the On Off Button on the control panel d Press the Mode Button until the AUTO appears on the LCD display e Select the fan speed by using FAN button During the AUTO model the unit operates at heating mode when the room temperature is below 68 degree It operates at dehumidifying mode when the room temperature is between 68 to 80 degree It operates at cooling mode when the room temperature is above 80 degree You may use the timer with the AUTO mode 6 Sleep Mode a The air conditioner in operation b Press SLEEP to enter into sleep mode c The fan motor of indoor unit runs in low speed d When in cooling mode within the first two hours the temperature will be increased 1 F per hour Then temperature will be keeping at 2 F higher than the original degree for 6 hours 6 hours later temperature will return to original degree you set e When in heating mode within the first 2 hours temperature will be decreased 1 F per hour Then temperature will be keeping at 2 F Lower than the original degree for 6 hours 6 hours later temperature will return to original degree you set g When in dehumidify mode the temperature will not be changed NOTE When the room temperature is low and the indoor hum
2. 2 NOTE 1 The above cooling capacity is measured at ambient temperature of DB 86 F WB 78 F 2 Noise level is measured at the point where is 3 28 ft away from the front of the unit in cooling mode 3 Power consumption is measured when fan runs at the highest speed Specifications above are for reference only Please see the actual data printed on the nameplate DISCLAIMER ALL INFORMATION AND THE TECHNICAL SPECIFICATIONS PRESENTED IN THIS USER S MANUAL ARE THE PRESENTATION OF THE MANUFACTURER SOLEUS INTERNATIONAL HAS NOT CONDUCTED INDEPENDENT TEST TO THE INFORMATION AND THE SPECIFICATIONS PRESENTED HEREWITHIN CONTACT INFORMATION Contact For Optional and Spare Parts Technical Support Warranty Claim Customer Service Soleus International Inc 9451 Telstar Ave El Monte CA 91731 USA 888 8 SOLEUS www soleusair com WARRANTY ONE YEAR LIMITED WARRANTY Soleus International Inc warrants the accompanying Soleus Air MAC 12K 10K Mobile Air Conditioner to be free of defects in material and workmanship for the applications specified in its operation instruction for a period of ONE 1 year from the date of original retail purchase in the United States or Canada If the air conditioner exhibits a defect in normal use Soleus International Inc will at its option either repair or replace it free of charge within a reasonable time after the air conditioner is returned during the warranty period As a condition to any warranty service o
3. Gl OWNER S MANUAL MAC T7OK MAC 12K Portable Air Conditioner Cooling Heating Dehumidifying Fan Please read this owner s Manual carefully before operating the unit ll TABLE OF CONTENTS Es EE IMPORTANT SAFEGUARDS ccc ccc cc ccccciiccciccccccesseeaae 2 PACKAGE CONTAINS EE 2 NAMES OF PARTS WEE 3 INSTALLATION BEFORE US 4 CONTROL PANEL AND LCD DISPLAY rererere 5 CONTROL PANEL FUNCTIONS 255362 2405255 2912462254720622 eee 6 OPERATION USING CONTROL DANI 7 OPERATION USING REMOTE CONTROLLER 9 MAINTENANCE sait ip Si t pata ba tapan ek ep buena s tan via an e bari patat koke eka erst Er 9 TECHNICAL SPECIFICATIONS EE ee ebe Deiere ee 10 DISCLAIMER EE 11 CONTACT INFORMATION cscs kd EENS EEN REENEN a 11 WARRANTY EE 12 INSTALLATION OF THE EWNTING KIT 0 0002rerreeerostrressrassrnassranssnnnnnn 13 2 INTRODUCTION Thank you for purchasing Soleus Air MAC 12K 10K portable air conditioner This unit is designed for improving living and working comfort by providing cooling dehumidifying and fan functions only with a minimum installation required With its quite operation and attractive design you will enjoy the convenience and comfort that this unit provides for many years to come When operating as an air conditioner this unit is designed for spot cooling or cooling for a room no larger than 400 square feet with the standard ceiling hei
4. bligation the consumer must present this Warranty Certificate along with a copy of the original purchase invoice THIS WARRANTY DOES NOT COVER 1 Damage accidental or other wise to the air conditioner while in the possession of a consumer not caused by a defect in material or workmanship 2 Damage caused by consumer misuse tampering or failure to follow the care and special handling provisions in the instructions 3 Damage to the finish of the case or other appearance parts caused by wear 4 Filter 5 Damage caused by repairs or alterations of the air conditioner by anyone other than authorized by Soleus International Inc 6 Freight and Insurance cost for the warranty service ALL IMPLIED WARRANTIES INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY ARE LIMITED TO ONE YEAR DURATION OF THIS EXPRESS LIMITED WARRANTY SOLEUS INTERNATIONAL INC DISCLAIMS ANY LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES AND IN NO EVENT SHALL SOLEUS INTERNATIONAL INC S LIABILITY EXCEED THE RETAIL VALUE OF THE AIR CONDITIONER FOR BREACH OF ANY WRITTEN OR IMPLIED WARRANTY WITH RESPECT TO THIS AIR CONDITIONER Installation of the Venting Kit FOR SOLEUS AIR EVAPORATIVE PORTABLE AIR CONDITIONERS b The venting kit must be installed in order for the unit to work correctly in the air conditioning or dehumidifying mode The venting kit does not need to be used while the unit is heating or fanning The window kit has been designed to fit in
5. ce It is recommended to clean the filter once every two weeks or as needed a b c a 2 Case Pull up the filter from the filter compartment in the back of the unit Wash the air filter by immersing it gently into warm about 104 F water with a neutral detergent Rinse the filter and dry it thoroughly in a shaded place Replace the filter back to the filter compartment after it is thoroughly dried If the filter is torn or unusable order a new filter by calling the contact section of this manual Keep the unit from being exposed directly to the sun for possible color fading Clean the surface with a damp cloth Dry it with a soft towel 3 Storing the Unit for an Extended Period of Time or Transporting a b Empty water by unplugging the water drainage stop at the back towards the bottom of the unit Unplug the unit c The unit should be stored in a cool dry place TECHNICAL SPECIFICATIONS MODEL MAC 10K MAC 12K COOLING CAPACITY 10 000 BTU H 12 000 BTU H HEATING 1200 W 1200 W DEHUMIDIFYING CAPACITY 50pts Day 60pts Day POWER COOLING 980W 1350W HEATING 1350W 1350W AIR FLOW VOLUME 300m h 300m h POWER SOURCE 115 V 60 HZ 115 V 60 HZ 9 12 AMP 12 12AMP HEATING COOLING HEATING COOLING SOUND PRESSURE LEVEL 46 dB A 46 dB A NET WEIGHT 80 LBs 82 LBs DIMENSIONS BODY 18x32x18 Inch 18x32x18 Inch PACKAGE 20x35x23 Inch 20x35x23 Inch REFRIGERANT R22 R2
6. eed to hookup the window kits and exhaust hose when you use the unit as a fan or a heater a b c d e f g h Pull out of both ends of the exhaust ducts for approximately 6 Screw clockwise the exhaust ducts with one end to the terminal end and other end to the window kit adapter Remove exhaust outlet wall covers from the back of the unit by screwing the covers counter clockwise before lifting them up Mount terminal ends of the exhaust hoses to the unit Open window or sliding door for approximately 5 inches 130 mm Adjust the length of the window kit to the same length of the window or the sliding door Use all three panels if necessary Cut the window piece as needed to fit the length of your window or sliding door Make sure that both holes on the main piece are not covered by other pieces Place the window kit to the window or sliding door Close the window or door as far as it goes Adjust the lengths of exhaust hose and affix the window kid adapters onto the holes on the window kit NOTE When using the window kit on a window or sliding door it will cause the window or sliding door not to be properly closed and locked Additional security measurements should be taken Wall Mount 1 2 Do not use window kit adapter Mount the one end of the exhaust ducts onto holes of 5 on the wall Using exhaust outlet wall covers to cover the holes in the wall when the unit is not in use NOTE In order
7. g efficiency 2 Dehumidifying Operation a Install the exhaust ducts properly b Plug the Power Cord to the power outlet c Turn on the unit by pressing the On Off Button on the control panel d Press the Mode Button until the DRY appears on the LCD display NOTE The unit operates at low fan speed during dehumidifying The unit cools room slightly during the dehumidification Keep the windows and the doors closed to aid the effectiveness of the unit in removing the moisture from the room NOTE The unit will not perform dehumidification when the room temperature is lower than 61 degree 3 Fan Operation a Plug the Power Cord to the power outlet b Turn on the unit by pressing the On Off Button on the control panel c Press the Mode Button until FAN appears on the LCD display d Select the fan speed by pressing the Fan Speed Button NOTE When the unit is running on fan mode the exhaust duct is inoperative and is not required 4 Heating Operation a Plug the Power Cord to the power outlet b Turn on the unit by pressing the On Off Button on the control panel c Press the Mode Button until HEAT appears on the LCD display d Press the Temperature Time Button or v until the desired room temperature appears on the LCD The temperature ranges from 61 F 88 F 16 C 31 C e Select the fan speed by pressing the Fan Speed Button It is recommended to use a low fan setting NOTE When
8. ght The unit also has power outage auto reset function The unit automatically returns to the original setting after a power outage IMPORTANT SAFEGUARDS Before you use your portable air conditioner please read this operation manual carefully L Never use or store gasoline or other flammable vapor or liquid near this unit 2 Maintain at least 10 25 CM clearance space from this unit Avoid air inlet or outlet grilles from being covered or closed off 3 The power supply must be properly grounded 4 Do not use an adapter plug or extension cord 5 Do not use the unit in the immediate surroundings of a bath a shower or a swimming pool 6 Do not let children play near this unit PACKAGE CONTAINS Mobile Air Conditioner Exhaust Duct 2 Unit Terminal End 2 Window Kit Adapter 2 Remote Controller AAA Batteries 2 Window Kit 3 Sliding Panels Exhaust Outlet Wall Covers 2 User Manual NAMES OF PARTS Front e Back Evaporator Air Intake Air Outlet Hose Air Intake Hose Drain Port Drain Port Exhaust Duct Exhaust Duct Window Kit Adaptor Window Kits INSTALLATION BEFORE USE 1 Exhaust Duct When you use the unit as an air conditioner or a dehumidifier the fresh outdoor air must be directed to the unit and the hot air must be exhausted out of the room to complete the air exchange When the unit is operating on fan or heating models no outdoor air exchange takes place You do not n
9. idity is high the condensate of the air conditioner may not be discharged in time Water will accumulate in the unit that leads to the unit stops working automatically for a long time At the moment the indicator lamp WATER FULL in the LCD is light In order to let your unit recover working quickly you can pull out the Drain Port which is located in the middle and bottom of the back of the unit The condensate will be discharged several minutes after water be drained Please use at least 1 5 liter pan to catch the dripping water It is not advised to use continuous drain method when the room temperature is higher than 90 F OPERATION USING REMOTE CONTROLLER The remote controller provided with the unit may operate this portable air conditioner The remote controller uses two AAA batteries provided Install the batteries before using the remote controller REMOTE CONTROLLER You may use the remote controller to do all the operations You can only turn on or off the swing operation from the remote controller The LTD displays on remote controller either in Celsius or Fahrenheit Press and keys simultaneously to change the display from Celsius to Fahrenheit or vice verse 10 MAINTENANCE Note Make sure power is off and the plug is pulled out of the power outlet before performing any maintenance activities 1 Clean or replace filter If the air filter is blocked with a lot of dust the airflow volume will redu
10. me Press Select key again until the display shows current time in a constant mode To program the timer press Select key until the LCD display shows a flashing on Pressing either A or V Temperature Time keys to change the clock to the desired time for the unit being turned on Press Select key one more time and the LCD display will show a flashing off Pressing either A or V Temperature Time keys to change the clock to the desired time for the unit being turned off Press the Select key again until the display shows a constant clock To activate the timer that you programmed press Set Cancel button to chose either on off or repeating on off of the timer operation OPERATION USING CONTROL PANEL 1 Cooling Operation a Install the exhaust ducts properly b Plug the Power Cord to the power outlet c Turn on the unit by pressing the On Off Button on the control panel d Press Mode Button until Cool appears on the LCD display e Press the Temperature Time Button or v until the desired room temperature appears on the LCD The temperature ranges from 61 F 88 F 16 C 31 C f Select the fan speed by pressing the Fan Button NOTE During hot days the unit will cool off the room most efficiently by setting the temperature at the lowest and the fan speed at the highest Reducing the length of the exhaust duct and insulating the exhaust duct and keeping direct sunlight to a minimum will also improve the coolin
11. to increase the efficiency the exhaust ducts should be keeping as short and straight as possible It is not recommended to increase the manufacturer s length of the exhaust hose This may impede or damage the unit CONTROL PANEL AND LCD DISPLAY CONTROL PANEL TEMP TIME TEMP TIME LCD DISPLAY AUTO COOL DRY HEAT FAN A vag TEMP pro TIMER EN C im IT o BEE Control Panel Functions 1 Power On Off Control Starts or Stops the Unit 2 Mode Control Select the functions of the unit for Fan Mode Air Conditioning Mode Heating Mode Dehumidifying Mode Auto Mode 3 4 5 Fan Speed Control Select the fan speed for High Medium Slow Auto Temperature Time Select the desired temperature by pressing either ror v key when using the unit in cooling or heating function The LCD flashes to displays the desired temperature during the setting The LCD displays set temperature when it is not at temperature setting mode The buttons are also used for setting time and timer The LTD display either in Celsius or Fahrenheit Press Temperature Time A and V keys simultaneously to change the display from Celsius to Fahrenheit or vice verse Select and Set Cancel Using Select and Temperature Time keys to set clock and timer To set clock press the Select key until the LCD display shows flashing current time Pressing either A or V Temperature Time keys to change the clock to the current ti
12. to most vertical and horizontal window openings The window kit can also be used in a sliding door 1 Choose an appropriate location close to a grounded electrical outlet and a suitable window or door 2 Remove the outlet covers from the back of the unit by screwing them counter clockwise then lifting up figure b 3 Pull out one end of the exhaust hose then screw on the adapter clockwise Repeat on other exhaust hose figure c 4 Pull out the opposite end of the exhaust hose then screw on the window kit adapter clockwise Repeat on other exhaust hose figure d 5 Mount the exhaust hoses onto the back of the unit figure e 7 Attach the window kit adapters to the window kit figure i Close the window or door tightly figure j Your Soleus Air portable air conditioner is now ready to cool 6 Open the window or door and adjust the length of the window kit to fit the opening figure f Mark the kit and cut it down to properly fit the opening if necessary figures g amp h When using the venting system keep the exhaust hose as short and straight as possible The exhaust hose can be shortened but it is not recommended to increase the length of the exhaust hose Do not use an extension cord with your portable air conditioner EE www soleusair com 15
Download Pdf Manuals
Related Search
Related Contents
boss®: back office system software Alcatel OneTouch 3040 Quick Start Manual V E CT R O N S Y S T E M S ACQUASPRINT IONO.indd FHE 550 A1 - Lidl Service Website VS-C - 富士フイルム FUTURA 26 IN FUTURA 35 IN Aaton Cantar-X2 Copyright © All rights reserved.
Failed to retrieve file