1. FILTER FILTER Remove aluminum filter by turning filter retainer to one side Fil ter should be washed once a month in a hot detergent solution Aluminum filters are dishwasher safe When installing filter make sure that filter slides under retaining tabs on back of fan housing Turn filter retainer so that arrows on retainer point toward front and back of hood WARNING ALWAYS DISCONNECT ELECTRIC POWER BEFORE SERVIC ING RANGE HOOD SCREWS FAN ASSEMBLY Remove filter Remove two screws holding motor bracket to range hood and unplug fan assembly Be careful not to allow fan as sembly to drop when screws are removed FIG 14 USE AND CARE CONTINUED CLEANING Clean your hood with a mild detergent suitable for painted sur faces DO NOT USE ABRASIVE CLOTH STEEL WOOL PADS OR SCOURING POWDERS Fan assembly may be vacuumed Fan assembly is permanently lubricated and never needs oiling HOW TO AVOID A COMMON RANGE TOP GREASE FIRE e Your range hood provides a protective barrier between the cooking surface and the cabinets e Keep fan filters and grease laden surfaces CLEAN accord ing to instructions e Always turn hood ON when cooking at high heat to keep the cooking area and the hood cooler e Use high heat settings only when necessary e Never leave cooking surface unattended Boil over causes smoking and greasy spillovers that may ignite e Always use adequate sized utensils elf preparing flaming foods
2. such as Cherries Jubilee always turn hood ON to HIGH to prevent a high heat situation which can cause damage or fire HOW TO EXTINGUISH A COMMON RANGE TOP GREASE FIRE e Never pick up a flaming pan If dropped flames can spread quickly e DO NOT USE WATER A violent steam explosion may re sult Wet dishcloths or towels are also dangerous e Smother flames with a close fitting lid cookie sheet or metal tray e Flaming grease can also be extinguished with baking soda or a multi purpose dry chemical extinguisher e Turn off surface units if you can do so without getting burned SERVICE PARTS 53000 SERIES 5 ROUND DUCTED HOOD KEY NO PART NO 98006621 99170245 99271248 99110437 97011217 99020248 99260428 98005568 97014665 97006931 99420472 97014729 97015347 99150471 99150470 DESCRIPTION Outlet Box Cover 8 x 3 8 Sheet Metal Screw Bulb Holder with Wires Light Lens Screw Nut Kit Includes 2 10 16 x 500 screws and 2 10 16 sheet metal nuts Fan Blade 6 32 Locking Nuts 2 Required Motor Mounting Bracket Motor Assembly Includes Key Nos 6 7 8 Aluminum Filter Filter Retainer Damper Assembly Motor Receptacle with Wires 10 32 x 1 2 Green Ground Screw 8 x 3 8 Sheet Metal Screw AB Point Light Bulb 75 Watt not included Order service parts by PART NO NOT by KEY NO Standard Hardware May be purchased locally Not Illustrated WARRANTY BROAN
3. 1 Follow appropriate directions below for type of duct run you install WALL CAP CABINET Wall Cap Discharge Use saber saw or keyhole saw to cut hole slightly larger than duct size used so that duct will line up easily with damper duct conector on hood Install casing strips if cap will be installed on siding Attach required amount of duct to wall cap and run duct back to hood Fasten cap to wall and caulk well ROOF CAP CABINET Roof Cap Discharge Cut a hole in roof slightly larger than duct size being used Run ductwork down to hood location Leave 3 4 of duct projecting above roof surface on high side Trim duct par allel to roof pitch and seal all around duct with roof cement Carefully trim shingles and slide back of roof sheet under shingles Nail roof sheet to roof under shingles at top two corners and two sides Nail sheet directly to roof in four places at bottom Using roof cement seal all nail heads and shingles which were cut or lifted Do not seal bottom edge of roof sheet INSTALL RANGE HOOD WARNING TURN OFF THE PROPER CIRCUIT AT THE SERVICE EN TRANCE BEFORE WIRING THIS RANGE HOOD IMPORTANT This hood is designed to be controlled using 2 separate gen eral use wall switches Use 3 wire plus ground power cable be tween switches and hood 3 WIRE PLUS GROUND POWER CABLE 1 Run power cable from location of switches to hood location and through hole drilled in wall or cabinet Split wiring for
4. 3 16 diameter mounting holes in hood PREPARE THE INSTALLATION LOCATION CONTINUED Ti HOOD WIDTH Additional 3 16 diameter mounting holes AIR y diameter 2 Measure and mark the following a Electrical wiring opening in wall or cabinet b Duct opening in wall or cabinet WARNING WHEN CUTTING OR DRILLING INTO WALL OR CABINET B CAREFUL NOT TO CUT EXISTING ELECTRICAL WIRING 3 Use 1 1 4 bit to drill opening for electric wiring 4 Cut out duct opening in cabinet with saber saw or keyhole saw Ir KEYHOLE SLOT OUTLINE 5 Center hood in installation opening and trace keyhole slots onto wood filler strips on cabinet bottom 6 Screw four 10 x 7 8 wood screws into exact center of narrow end of traced keyhole slots Allow 3 8 of screws to project so that hood can be fitted into place later INSTALL THE DUCTWORK NOTE These instructions will follow plans made on Page 2 Start at the exterior and run ductwork back to the range hood For best possible performance use the shortest possible duct run and a minimum number of elbows Do not vent a range hood into an attic space A buildup of grease in the attic could become a fire hazard Use only metal ductwork DO NOT USE PLASTIC DUCT Assemble duct run securely so that in case of a grease fire on the range the fire will be contained inside metal ductwork Use duct tape to make all duct connections secure and air tight
5. ONE YEAR LIMITED WARRANTY Broan warrants to the original consumer purchaser of its products that such products will be free from defects in materials or workmanship for a period of one year from the date of original purchase THERE ARE NO OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE During this one year period Broan will at its option repair or replace without charge any product or part which is found to be defective under normal use and service THIS WARRANTY DOES NOT EXTEND TO FLUORESCENT LAMP STARTERS AND TUBES This warranty does not cover a normal maintenance and service or b any products or parts which have been subject to misuse negligence accident improper maintenance or repair other than by Broan faulty installation or installation contrary to recommended installation instructions The duration of any implied warranty is limited to the one year period as specified for the express warranty Some states do not allow limitation on how long an implied warranty lasts so the above limitation may not apply to you BROAN S OBLIGATION TO REPAIR OR REPLACE AT BROAN S OPTION SHALL BE THE PURCHASER S SOLE AND EXCLUSIVE REMEDY UNDER THIS WARRANTY BROAN SHALL NOT BE LIABLE FOR INCIDENTAL CONSEQUENTIAL OR SPECIAL DAMAGES ARISING OUT OF OR IN CONNECTION WITH PRODUCT USE OR PERFORMANCE Some states do not allow the exclusion or limitat
6. 6 and install proper connector for type of wire used 2 Position hood so that a Power cable is routed through knockout opening b Large part of keyhole slots fit over hood mounting screws c Damper duct connector slides into ductwork 3 Adjust hood so that hood front is flush with cabinet frame Tighten hood mounting screws firmly A 5 Fasten wiring to hood with proper electrical connector for type of wire being used WIRING SCHEMATIC 3 wire plus ground power cable RANGE HOOD r BLACK BLACK LIGHT FAN 120 VAC LINE IN INSTALL RANGE HOOD conrtinueo RANGE HOOD WIRING WHITE A TO ye NN we oo Bare or green wire WARNING ALL ELECTRICAL CONNECTIONS MUST BE IN ACCOR DANCE WITH LOCAL CODES ORDINANCES OR NATIONAL ELECTRICAL CODE IF YOU ARE UNFAMILIAR WITH METH ODS OF INSTALLING ELECTRICAL WIRING SECURE THE SERVICES OF A QUALIFIED ELECTRICIAN 6 Strip 1 2 of insulation from wires Connect white to white black to black red to red and green or bare wire beneath green ground screw provided 7 Replace wiring box cover and screw Make sure that all wir ing is safely contained inside LIGHT LENS 8 Install light 75 Watt maximum For easier installation squeeze plastic lens and remove it from hood Remember to reinstall lens 9 Turn on power and check operation of fan and light Make sure that damper operates freely USE AND CARE FILTER RETAINER
7. A O OOOO BROAN 53000 SERIES RANGE HOOD 5 ROUND DISCHARGE READ AND SAVE THESE INSTRUCTIONS WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR IN JURY TO PERSONS OBSERVE THE FOLLOWING 1 Use this unit only in the manner intended by the manufacturer If you have questions contact the manufacturer at the address or telephone number listed in the warranty 2 Before servicing or cleaning unit switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally When the service disconnecting means cannot be locked securely fasten a prominent warning device such as a tag to the service panel 3 Installation work and electrical wiring must be done by a quali fied person s in accordance with all applicable codes and standards including fire rated construction codes and stan dards 4 Sufficient air is needed for proper combustion and exhausting of gases through the flue chimney of fuel burning equipment to prevent backdrafting Follow the heating equipment manufacturer s guideline and safety standards such as those published by the National Fire Protection Association NFPA and the American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE and the local code authori ties 5 When cutting or drilling into wall or ceiling do not damage elec trical wiring and other hidden utilities Ducted fans must always be vented to t
8. With Homeowner HOMEOWNER Use and Care Information on Page 5 PLANNING DUCTWORK INSTALLATION Begin planning ductwork by deciding where the duct will run be tween the range hood and the outside For best performance use the shortest possible duct run and a minimum number of elbows ROOF CAP a 5 ROUND DUCT MODEL P85 DAMPER Straight up through the roof using 5 round duct for single story installations only ADJUSTABLE WALL CAP Ducting between the ceiling joists for multi story installations or through the soffit soace above the cabinets where the soffit con nects to an outside wall PREPARE THE HOOD 1 Unpack hood and check contents You should receive 1 Aluminum Filter 2 Remove wiring box cover Under cover find 1 Plastic Bag containing ware loose mounting hard 3 Remove top or rear electrical Knockout 4 Install Model P85 damper over opening in top of hood Use three 3 screws provided with damper PREPARE THE INSTALLATION LOCATION Omit STEP 1 if hood will be installed under cabinets with flush bottom 1 For installation on recessed bottom cabinets only Attach a wood filler strip at each side of recessed area under cabinet Use two 1 x 2 strips cut to length If recess is deeper than 1 use thicker strips Attach strips with 1 1 4 wood screws 3 from each end of strip Optional Attach wood filler strips under front and back of cabi net and use additional
9. by NFPA NO CAUTION 1 For general ventilating use only Do not use to exhaust hazardous or explosive materials and vapors 2 To avoid motor bearing damage and noisy and or unbalanced impellers keep drywall spray construction dust etc off power unit 3 For best capture of cooking impurities your range hood should be mounted 18 24 above the cooking surface 4 Please read specification label on product for further information and requirements 5 This range hood is designed for use with two 2 wall mounted general use 15 Amp switches for control of the fan and light purchase separately TOOLS AND MATERIALS REQUIRED Drill electric or ratchet drive 1 8 Drill bit for drilling pilot holes 1 1 4 wood bit for drilling electrical wiring access hole One straight blade and one phillips head screwdriver Pliers Pencil and ruler and or tape measure Saber saw or keyhole saw for cutting 1 x 2 wood strips to length and cutting wall or cabinet openings Caulking metal snips duct tape duct with elbows and transi tion if necessary and roof or wall cap as required LI Electrical wiring and supplies of type to comply with local codes The following materials are required only for installations on re cessed bottom kitchen cabinets 1 Two 1 x 2 x 12 approximate length wood strips purchase locally 1 Four 1 1 4 long flat head wood screws purchase locally DO DOCOCOCO INSTALLER Leave This Manual
10. he outdoors Do not use this range hood with an additional speed control device 8 To reduce the risk of fire use only metal ductwork 9 This unit must be grounded TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE 1 Never leave surface units unattended at high settings Boilovers cause smoking and greasy spillovers that may ig nite Heat oils slowly on low or medium settings 2 Always turn hood ON when cooking at high heat or when cooking flaming foods 3 Clean ventilating fans frequently Grease should not be al lowed to accumulate on fan or filter 4 Use proper pan size Always use cookware appropriate for the size of the surface element TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE OBSERVE THE FOLLOWING 1 SMOTHER FLAMES with a close fitting lid cookie sheet or metal tray then turn off the burner BE CAREFUL TO PRE VENT BURNS If the flames do not go out immediately EVACU ATE AND CALL THE FIRE DEPARTMENT 2 NEVER PICK UP A FLAMING PAN You may be burned 3 DO NOT USE WATER including wet dishcloths or towels a violent steam explosion will result 4 Use an extinguisher ONLY if A You know you have a Class ABC extinguisher and you already know how to operate it B The fire is small and contained in the area where it started C The fire department is being called D You can fight the fire with your back to an exit Based on Kitchen Fire Safety Tips published
11. ion of incidental or consequential damages so the above limitation or exclusion may not apply to you This warranty gives you specific legal rights and you may also have other rights which vary from state to state This warranty supersedes all prior warranties To qualify for warranty service you must a notify Broan at the address stated below or telephone 1 800 637 1453 b give the model number and part identification and c describe the nature of any defect in the product or part At the time of requesting warranty service you must present evidence of the original purchase date Broan NuTone LLC 926 West State Street Hartford WI 53027 1 800 637 1453 99043003B

Download Pdf Manuals

image

Related Search

Related Contents

Tripp Lite SmartOnline 110-120V 2.2kVA 1.6kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, Tower, USB, DB9 Serial  Micro-joystick - mo-Vis  La communication publique territoriale :  Brodit 513405 holder  #29266 XP LED RC Light Kit (12pcs)  DTMRX2 - Videotec  Installation and Operating Instructions  