Home
Pyle PT-3200 Amplifier Car Audio Amplifier
Contents
1. CHANNEL A yy evee _ NM yy never mono aniosen C CHANNEL B Left and Right Output Level Controls Lets you adjust the sound levels for each channel Clip Circuit and Indicator This special circuitry protects the amplifier and speaker system from being damaged by overdriving power levels Indicator lights remind the user to reduce the volume when amplifier output is excessive REAR PANEL PT3200 and PT4000 CHB PYT 3200 POWER AMPLIFIER 7 Left and Right Power Meters Indicates the output signal level for each channel Prha A ol a1 2 ay Sig AEE BP u rr TOTAL OUTPUT POWER ne BAY a 01 z RIA ed 7 E SIGNAL CLIPPING PROTECTION O O Q CHA CIRCUIT BREAKER OUTPUT N AC POWER enoee ND GROUND LIFT LIFT SIGNAL CLIPPING PROTECTION O O 0O Power On Off Signal Indicators When signal is present these indicators are illuminated Protection Circuit and Indicator These indicators are illuminated when the amplifier is powered on and at turn on delay status the indicators will turn off after internal outputs are connected These indicators will also be illuminated when the amplifier has abnormal problems such as overload or excessive heat INPUTS CHB CHA CHB CHA STEREO BRIDGE m Speaker termina
2. dark environments the meter is illuminated Using the Left and Right Output Level controls Rotate output level gain clockwise to increase or counter clockwise to decrease the output power To get the best performance with the least sound distortion always adjust the output level gain so the meter s pointer does not continuously exceed the extreme right of the meter s scale CAUTION It is possible to overdrive the amplifier by setting output level gain too high which may cause damage or failure About the internal clip circuitry Special clip circuitry incorporated into your Pyle Pro amplifier s design protects the amplifier and speaker system from being damaged from overdriving power Under normal conditions the amplifier s clip indicator will flicker as the output power momentarily exceeds the level as set by the output level gain selector However under excessive output conditions the clip indicator lights remain on continuously alerting you that the special clip circuitry has become active When this occurs you should simply reduce the output power level by rotating the Master Volume control counterclockwise PYLE PRO PT3200 4000 Amplifier Owner s Manual 3 Caring for your Pyle Pro Amplifier Your Pyle Pro Amplifier is an example of superior design and craftsmanship The following suggestions will help you care for your amplifier so you can enjoy years of use e Keep the amplifier dry If it gets wet wipe imm
3. over 25 feet It is recommended that you use the shortest length of wire possible 2 Connect the speaker wires to the speaker s positive and negative terminals NOTE Most speaker terminals are either color coded or have a mark that indicates the terminal s polarity Usually positive terminals are red or have a plus symbol and negative terminals are black or have a minus symbol 3 Connect the speaker wires to the amplifier s left and right speaker terminals according to the terminal color polarity STEREO OPERATION SWITCH IN STEREO POSITION Co BREAKER oar AC POWER IN I SIGNAL a o o o CAUTION Do not use balanced and unbalanced inputs simultaneously MONO OPERATION SWITCH IN MONO POSITION c eu ie as Cs ac Power in w Cs S SIGNAL SOURCE USE CHANNEL A INPUT ONLY CAUTION Do not use balanced and unbalanced inputs simultaneously Bridged Mode Operation This amplifier can operate in a mono bridged output mode if your speakers can handle the following power output levels PT 3200 600 watts PT 4000 800 watts As shown in the diagram below connect the speaker s positive to the amplifier s red speakers left A B terminals and negative to red speakers right A B terminals The speaker right on the amplifier
4. DARPATI A Owner s Manual w Please complete warranty card detach and return W Thank you for purchasing this PYLE product To activate yong warranty registration card warranty please mail this card within 10 days PYE PRO AMPLIFIERS Name Address City State ZIP Model No Serial if available Date of Purchase Purchased at Music Products Store O Sound Contractor Installer C Mail Order Catalog Merchandiser Other Your new Pyle Pro PT Series P A Amplifier gives you the power and versatility you need in a professional sound system The amplifier s wide frequency response makes it suitable for amplifying music or vocal program material It can be used for live bands office paging systems public annoucement systems or a variety of other installations SPYLE CPRO TABLE OF CONTENTS Van bhR ABR RWWWNNNND Features and controls PT3200 and PT4000 Installation Guidelines Input Connections Connecting a CD or tape player or tuner Connecting an equalizer or signal processor Speaker connections Bridged Mode Operation Connecting to AC power Mounting the amplifier Turning the amplifier on Using the power meterS Using the left and right output level controls About the internal clip circuitry Caring for your Pyle Pro Amplifier Resetting the circuit breaker Specifications Limited warranty Please read this manual thoroughly before you attempt to set up and use the amplifier It
5. contains a range of installation suggestions as well as instructions to ensure safe usage Installed properly you can expect years of trouble free service from this product Left and Right Power Meters Indicates the output signal level for each channel FEATURES AND CONTROLS FRONT PANEL PT4000 SPYLE CPRO PROTECTION CHANNEL A ii I ly L LOG E MONO O CLIPPING BAIDGED O SIGNAL Power On Off Left and Right Output Level Controls Lets you adjust the sound levels for each channel Signal Indicators PYT 4000 POWER AMPLIFIER A Protection Circuit and Indicator These indicators are illuminated when the amplifier is powered on and at turn on delay status the indicators will turn off after internal outputs are connected These indicators will also be illuminated when the amplifier has abnormal problems such as overload or excessive heat TOTAL OUTPUT POWER a 1a 7 6 12 20 oe n a aa PROTECTION CHANNEL B CLIPPING p lly LEVEL SIGNAL A Clip Circuit and Indicator This special circuitry protects the amplifier and speaker system from being damaged by overdriving power levels Indicator lights remind the user to reduce the volume when amplifier output is excessive When signal is present these indicators are illuminated FEATURES AND CONTROLS FRONT PANEL PT3200 o gt PYLE PRO
6. d use the RCA JACKS for connecting a CD player tape player or tuner OUTPUT e O CD PLAYER TAPE PLAYER OR TUNER m Connecting an equalizer or external signal processor Connect the processor s OUT to the amplifier s INPUT connectors OUTPUT cHE cHa BREAKER FN sna LP use XLR 6 35 mm combo jacks 2 PYLE PRO PT3200 4000 Amplifier Owner s Manual Stereo or Mono Inputs Your Pyle Pro amplifier can be operated in Stereo Mono or Bridged mode depending on the input source If the input signal is mono slide the Stereo Mono Bridged selector switch to MONO and the signal will be routed through both channels If you wish to run the amplifier in bridged output mode slide the switch to Bridged Speaker connections You can connect 4 Ohm 8 Ohm or 16 Ohm speakers to Channel A and or Channel B of the amplifier If you connect two pairs of speakers be sure to follow these guidelines e Speakers which are connected to the same channel are part of a pair and must be of the same impedance e Speakers connected to different channels are NOT part of a pair and can be of different impedances 1 Prepare the speaker wire by removing about 1 inch of insulation from the end of the speaker wire you intend to connect to the amplifier Then twist the exposed wire to secure all the wire strands NOTE Use 16 gauge speaker wire for lengths up to25 feet 14 gauge wire for lengths
7. ediately e Use the amplifier only in well ventilated installations e Handle the amplifier gently and carefully do not drop e Keep the amplifier away from dust and dirt e Wipe occasionally with a damp cloth to keep it looking new Do not use harsh chemicals solvents or detergents Resetting the circuit breaker This amplifier employs a circuit breaker for protection from power surges and short circuits If the amplifier suddenly turns off or will not turn on check the circuit breaker If it is tripped check and correct for a short or overload condition Wait for the amplifier to cool then press the circuit breaker RESET button on the back of the amplifier Resetting the circuit breaker This amplifier employs a circuit breaker for protection from power surges and short circuits If the amplifier suddenly turns off or will not turn on check the circuit breaker If it is tripped check and correct for a short or overload condition Wait for the amplifier to cool then press the circuit breaker RESET button on the back of the amplifier Limited Warranty All PYLE PRO products are carefully constructed and tested before shipment Units purchased in the USA are warranted to be free of defects in material and workmanship for two 2 years from the date of purchase This warranty is limited to the original retail purchaser of the amplifier Should the unit fail due to factory defects in material or workmanship your unit will be r
8. epaired or replaced at the sole discretion of PYLE To obtain warranty service you must first call our Consumer Return Hotline at 718 236 6948 to obtain a Return Authorization Number This R A must appear on the outside of your package and on all paperwork relating to your return When returning the unit to us for warranty service it must be carefully packed and shipped prepaid to R A PYLE PRO Service Center 1600 63rd Street Brooklyn NY 11204 You must also include the following items with your return e A copy of your sales receipt or other proof of purchase e A brief letter indicating the problem you are experiencing with the product e Include in your letter your return address daytime phone number and R A number e Also include a check or money order for 15 00 for return shipping handling and insurance or provide your Visa MC number with expiration date Our obligation under this warranty is limited to the repair or replacement of the defective unit when it is returned to us prepaid This warranty will be considered void if the unit was tampered with improperly serviced or subject to misuse neglect or accidental damage Power Requirement 120 VAC 60 Hz 120 VAC 60 Hz Dimensions HxWxD inches mm Weight lbs kg 5 gt PYLE CPRO 4 PYLE PRO PT3200 4000 Amplifier Owner s Manual Amplifier Specifications PT3200 PT4000 i Input Impedance balanced unba
9. is used as a negative terminal for a bridged connection NOTE The extra amplifier output of 6 35mm phone jacks can not be used for the bridged connection It can only be used in normal non bridged operation as a stereo speaker output MONO BRIDGED OPERATION SWITCH IN BRIDGED POSITION MONO BRIDGE CE DO NOT USE BLACK TERMINALS C BREAKER e C oe Cs acrowerin eS gt Ma d T ES SIGNAL SOURCE USE CHANNEL A INPUT ONLY CAUTION Do not use balanced and unbalanced inputs simultaneously Connecting to standard AC power After making all other connections set the POWER switch to OFF position Then connect the power cord to a standard AC outlet Mounting the amplifier This amplifier is designed to accept standard rack mounting installations Two slots on each end of the front panel make it suitable for such an installation Tightly secure four mounting screws not supplied through these fours slots and into your standard electronics equipment rack Turning the amplifier on 1 Turn on the audio input source equipment which is connected to the amplifier INPUT jacks 2 Set the amplifier s Channel A and Channel B output level gain controls to the minimum level settings 3 Push in the power switch to turn the amplifier on Using the power meters The meter pointer position indicates the amplifier output power For ease of reading in
10. lanced 20 k Ohms 10 k Ohms 20 k Ohms 10 k Ohms Continuous Output Power i 1 v 2y Stereo Mode E 5 20 Hz to 20 kHz 8 Ohms 200W x 2 260W x 2 i Z S I 1 kHz 4 Ohms 300W x 2 400W x 2 i n Maximum Power 8 Ohms 230W x 2 300W x 2 1 Maximum Power 4 Ohms 350W x 2 450W x 2 l Peak Power 8 Ohms 1600W x 2 2000W x 2 VU lt t i G Bridged Mode l T O 20 Hz to 20 kHz 8 Ohms 500W x 1 700W x 1 I a ww N 1 kHz 8 Ohms 600W x 1 800W x 1 1 OUO Peak Power 3200W x 1 4000W x 1 l Oo U I a THD at rated output power 0 1 0 1 I a YA 1 Frequency Response 3 dB 10 Hz to 50 kHz 10 Hz to 50 kHz l O D I A Input Sensitivity for rated output power 1 0V 1 0V i aad iad Signal to Noise Ratio A Weighted 100 dB 100 dB oO 0 Z Speaker Impedance l L 2 Stereo 4 16 Ohms 4 16 Ohms l pez O Bridged 8 16 Ohms 8 16 Ohms i Qa I I I 1 I I I 1 I I I I I l 3 15 32 X 19 x 14 88 x 482 x 355 30 6 13 96 3 15732 X 19 x 14 88 x 482 x 355 33 0 15 1 PYLE PRO PT3200 4000 Amplifier Owner s Manual 5
11. ls Permits hookup of A stereo pair of speakers or a bridged speaker via the wire terminals Fan Cooling Input Jacks Lets you connect a variety of audio input sources via the balanced XLR 6 35mm phone Stereo Mono Selector Lets you select conventional stereo operation with a stereo input signal or bridged mono input mode jack combinations or unbalanced RCA inputs 5 gt PYLE CPRO PYLE PRO PT3200 4000 Amplifier Owner s Manual Cooling system is automatically activated whenever amplifier is turned on This forced air cooling system rapidly exhausts interior heat reducing operating temperature and aiding performance PYLE PRO PT3200 4000 Amplifier Owner s Manual 1 INSTALLATION GUIDELINES Connecting the GND Ground screw terminal Connecting a mixer or preamplifier may cause excessive noise or hum in the amplifier output To prevent this connect one end of a low capacitance shielded wire to the amplifier s ground screw on the rear panel Then connect the other end of this wire to the ground terminal on the mixer or preamplifier enclosure 7 z PREAMP OR MIXER GROUND SCREW LOW CAPACITANCE SHIELDED WIRE Input connections These amplifiers accept a broad range of input sources including Compact Disc CD players Cassette Reel to Reel or other tape players Radio Tuners Equalizers Signal Processors Connecting a CD or tape player or tuner In a normal installation one woul
Download Pdf Manuals
Related Search
Related Contents
Avaya BCM50 Installation and Maintenance Manual Manual do Usuário Nokia 1616 Serveur HP ProLiant ML150 Manuel d`installation et d`utilisation du H-2000H-3500_Operating_Manual Elections, mode d`emploi ! VERARBEITUNGSHINWEISE HANDLING INSTRUCTIONS VXP Owner`s Manual FurReal Friends Baby Butterscotch 52194 Instructions Consulter le document... - Ville de Soisy-sous Copyright © All rights reserved.
Failed to retrieve file