Home
Broan-NuTone RL6136F Kitchen Hood
Contents
1. ROOF CAP CASQUETE DE TECHO 3 1 4 x 10 DUCT DUCTO DE 3 1 4 x 10 FIG 1D ADJUSTABLE ELBOW CODO AJUSTABLE WALL CAP CASQUETE DE 3 1 4 x 10 TO 6 ROUND DUCT TRANSITION TRANSICI N DE 3 1 4 x 10 A UN DUCTO REDONDO DE 6 6 ROUND DUCT DUCTO REDONDO DE 6 ROOF CAP CASQUETE DE FECHO Y 6 ROUND DUCT DUCTO REDONDO DE 3 1 4 x 10 TO 6 ROUND DUCT TRANSITION TRANSICI N DE 3 1 4 x 10 A UN DUCTO REDONDO DE 6 ROOF CAP CASQUETE DE TECHO 7 ROUND DUCT DUCTO REDONDO DE 7 DAMPER REGISTRO DETIRO PRECAUCION 1 Solamente para uso general de ventilaci n No utilice para descargar materiales o vapores riesgosos o explosivos 2 Para evitar da os al motor y evitar que las navajas del abanico emitan mucho ruido o est n fuera de balance mantenga el motor libre de pelusa polvo etc 3 El motor de su extractor tiene dispositivo de sobrecarga t rmica al cual autom ticamente apagar el motor si se sobrecalienta El motor funcionar de nuevo cuando se enfr e Si el motor continua apag ndose y arrancando h galo componer 4 Para obtener mejores resultados en la captura de los vapores de la estufa el extractor debe montarse a entre 18 y 24 plg sobre las hornillas de la estufa 5 Por favor lea la etiqueta con las especificaciones del equipo para otros requisitos y mayor informaci n HERRAMIENTAS Y MATERIALES QUE SE REQUIEREN HERRAMIENTAS Taladro el ctric
2. Para obtener un mejor rendimiento alinee la placa del conducto redondo l de 17 8 cm 7 con la abertura redonda de 17 8 cm 7 de la campana Monte la placa del conducto a la campana con dos tornillos desde la placa del conducto y con dos tornillos desde el tiro de 8 3 x 25 4 cm 3 14 x 10 Instale un regulador de tiro redondo de 7 se compra por separado La aleta del regulador se debe abrir libremente en direcci n del flujo de aire en sentido contrario a la campana de la estufa PREPARANDO LA UBICACION DE LA INSTALACION NOTA MONTE EL EXTRACTOR DE MANERA QUE LA PARTE INFERIOR ESTE 18 24 ENCIMA DE LA SUPERFICIE DE LA COCINA LA PARTE SUPERIOR DEL FRENTE DEL EXTRACTOR DEBE DE ESTAR A RAS CON EL FRENTE DEL ARMAZ N DEL GABINETE SI LA DISTANCIA ENTRE LAPARED Y LA PARTE FRON TAL DEL ARMAZ N DEL GABINETE ES MAS DE 12 HABR UN ESPACIO ENTRE LA PARTE DE ATRAS DEL EXTRACTOR Y LA PARED ESTO ES NORMAL OMITA PASO 7 si el extractor estar instalado debajo de un gabinete con la parte inferior plana 9 Para instalaci n en gabinetes ahuecados solamente Sujete una tira de madera a cada lado de la parte inferior ahuecada debajo del gabinete Use dos tiras de madera de 1 x 2 cortadas al largo necesario Si el ahuecamiento es m s de 1 use tiras m s gruesas Sujete las tiras con tornillos de 1 1 4 a una distancia de m s o menos 3 del extremo V ase FIG 7 IDUCTWORK NOTE THESE INSTRUCTIO
3. Aseg rese que todo el cableado est dentro de la caja NOTA Para instalaci n sin ducto solamente Instale ambos filtros Aseg rese que el filtro compra separado que no necesita ducto est m s cerca del emsamblaje del ventilador con el lado azul hacia las aspas El filtro de aluminio debe de estar en la parte exterior USO Y MANTENIMIENTO INTERRUPTORES La perilla a la derecha controla la luz La perilla de la izquierda controla el ventilador o abanico D la vuelta en direcci n horaria para prender el ventilador ON a la velocidad ALTA Volte ndola m s en direcci n horaria reduce la velocidad del abanico D la vuelta a la perilla completamenta en direcci n antihoraria m s all de la velocidad ALTA para apagar el abanico OFF LIMPIEZA Acabado Mantenga el extractor limpio usando un detergente suave apropiado para superficies pintadas Filtros aluminio Deber an limpiarse frecuentemente en una soluci n de detergente para evitar la acumulaci n de grasa Estos pueden ser lavados en la lavadora de platos QUITANDO EL FILTRO Los filtros se sacan moviendo la grampa del filtro a un lado y levantando el filtro o los filtros hacia afuera En la versi n con ductos d la vuelta a la grampa retentora del filtro a un lado y ponga el filtro de aluminio debajo de las u as resaltadas retentoras en la parte de atr s de bastidor del ventilador o abanico De la vuelta a la grampa del filtro de manera que el extre
4. FIG 7 amp 8 a Abertura para la linea el ctrica 11 Perfore cuatro huecos pilotos en las esquinas ya marcadas de la abertura para el ducto como se muestra y luego corte un abertura con un serrucho sable o un serrucho para cerradura 12 Usese una broca de 1 1 4 para perforar una abertura para la conexi n el ctrica en la pared o gabinete 13 Sostenga al extractor debajo de la parte inferior del gabinete y trace las ranuras en forma de hueco de cerradura en la parte inferior del gabinete donde se instalar n las tiras de madera 14 Atornille cuatro de los tornillos de madera de 7 8 para montar el extractor en el centro exacto de la parte estrecha de la ranuras en forma de cerradura que se marcaron debajo del gabinete Permita que 3 8 de los tornillos queden afuera para que luego pueda instalarse al extractor en su sitio NOTESE ESTAS INSTRUCCIONES SEGUIR N LOS PLANES HECHOS EN LA P GINA 2 COMIENCE EN LA PARTE EXTERIOR Y TRAIGA EL DUCTO HACIA EL EXTRACTOR PARA EL MEJOR RENDIMIENTO DE SU EXTRAC TOR USE EL CAMINO MAS CORTO DE DUCTO Y UN M NIMO DE CODOS NUNCA DESCARGUE EL AIRE DEL EXTRACTOR EN EL ESPACIO DE LA BUHARDILLA PORQUE UNA ACUMULACI N DE GRASA PODR A CAUSAR UN INCENDIO USE SOLAMENTE DUCTOS DE METAL NO USE DUCTOS DE PLASTICO ENSAMBLELOS BIEN DE MANERA QUE EN CASO DE QUE HUBIESE UN INCENDIO CAUSADO POR GRASA EL INCENDIO SE QUEDARA CONTENIDO DENTRO DE LOS DUCTOS DE METAL ES UNA BUENA PRACTICA EL P
5. Use an extinguisher ONLY if A You know you have a Class ABC extinguisher and you already know how to operate it B Thefire is small and contained in the area where it started C The fire department is being called D You can fight the fire with your back to an exit Based on Kitchen Fire Safety Tips published by NFPA INSTALLER Leave This Manual With The Homeowner HOMEOWNER Use and Care Information on Page 5 INSTALADOR Deje este manual con el due o de la casa DUE O DE LA CASA Informaci n acerca del uso y los cuidados en la P gina 5 CAMPANA EXTRACTORA 4 WAY CONVERTIBLE SERIE RL6100F LEA Y CONSERVE ESTAS INSTRUCCIONES IMPORTANTE Para instalaci n sin ducto a Compra el filtro sin conductos separado b Quite y descarte el conector del regulador ducto y la tapa de la rejilla V ase paso 4 en la P gina 2 titulada Prepare el extractor c Siga todos los pasos excepto de los pasos dentro las l neas suspensivas Para instalaci n con ducto las l neas suspensivas L p J ADVERTENCIA PARA REDUCIR EL RIESGO DE INCENDIO CHOQUE ELECTRICO O LESION A PERSONAS PROCURE LO SIGUIENTE 1 Utilice esta unidad s lo en la manera prescrita por el fabricante Si tiene usted alguna pregunta comun quese con el fabricante a la direcci n o el tel fono indicados en la garant a 2 Antes de limpiar o de poner en servicio la unidad apague el interruptor en el panel de servic
6. securely Make electrical connection using wire nuts to con nect white wire to white black wire to black Ground hood to prepared hole using green ground screw provided FIG 12 22 Replace wiring box cover and screw Make sure that all wiring is safely contained inside NOTE For Ductfree Installations Only Install both filters Make sure that ductfree filter purchase separately is nextto fan assembly with blue side next to blade Aluminum filter should be 2 ari facing out USE AND CARE SWITCHES Right knob controls light Left knob controls blower Rotate knob CLOCKWISE to turn blower ON to HIGH speed Further CLOCK WISE rotation decreases blower speed Rotate knob fully COUNTERCLOCKWISE past HIGH speed to turn fan OFF CLEANING Finish Keep your range hood clean using a mild de tergent suitable for painted surfaces Aluminum Filters should be cleaned frequently with a detergent solution to avoid grease build up They are also dishwasher safe FILTER REMOVAL Filters are removed by turning filter clip to the side and lifting filter or filters out In ducted version turn filter retaining clip to one side and place aluminum filter under embossed retaining tabs on back of fan hous ing Turn filter clip so that the low end of clip holds single filter firmly in place FIG 13 In ductfree version place both aluminum and ductfree filter under tabs on back of fan housing Turn filter re taining clip
7. so that high end holds both filters firmly in place Make sure ductfree filter is next to fan assem bly with blue side next to fan blade and aluminum filter is facing out NOTE Make sure that arrows on filter retaining clip point toward back and front of hood LIGHT BULB REPLACEMENT Light bulb not supplied with hood should be 75 watts maximum The lens covering bulb is removed by press ing the two extending tabs together until they release from the retaining slots FIG 14 FAN ASSEMBLY REMOVAL Be sure power is disconnected Remove filters Re move the two screws holding the motor bracket to the range hood and unplug the fan assembly Be careful not to allow fan assembly to drop when the screws are removed FIG 15 FIG 10 7 sel CONNECTOR A CONECTOR GB GREEN GROUND SCREW TORNILLO VERDE PARA TIERRA GROUND WIRE BARE OR GREEN WIRE ALAMBRE DE TIERRA SS Phl ALAMBRE DESNUDO O __ VERDE STAR LOCKNUT ELECTRICAL LINE LINEA ELECTRICA BLACK WIRES ALAMBRES NEGROS WHITE WIRES ALAMBRES BLANCOS GROUNDING BRACKET SOSTEN PARA TUERCA TRABANTE SONECTARA TIERRA EN FORMA DE ESTRELLA NON DUCTED FILTER SOLD SEPARATELY FILTRO QUE NO REQUIERE DUCTO VENDIDO SEPARADAMENTE FIG 15 SCREWS TORNILLOS FILTER RETAINING CLIP GRAMPA RETENTORA DEL FILTRO ALUMINUM FILTER FILTRO DE ALUMINIO LIGHT LENS VIDRIO QUE CUBRE EL BOMBIL O INSTALANDO EL EXTRA
8. A dl N 98005221 99100379 97005544 NTK7592 NTK7615 99091078 99030172 99030248 99091078 99030171 99030247 561120 97005678 99091022 99091020 99091021 99091027 R680508 dc a ONA Order service parts by PART NO NOT by KEY NO Standard Hardware May be purchased locally Outlet Box Cover 8 x 3 8 Sheet Metal Screw Bulb Holder with Wires Light Lens Screw Nut Kit Includes 2 10 16 x 500 screws and 2 10 16 sheet metal nuts Fan Blade 6 32 Locking Nuts 2 Required Motor Mounting Bracket Motor Assembly Includes Key Nos 6 7 and 8 Aluminum Filter Non Ducted Filter purchase separately Filter Retainer 8B x 1 4 Hex Head Sheet Metal Screws 2 Req Damper Flap Damper Bushing Damper Assembly Includes Key Nos 13 and 14 Nameplate Black Nameplate White Nameplate Biscuit 2 Speed Motor Switch Black 2 Speed Motor Switch White 2 Speed Motor Switch Biscuit Light Switch Black Light Switch White Light Switch Biscuit Motor Receptacle with Wires Louver Cover Black Louver Cover White Louver Cover Almond Louver Cover Biscuit 7 Round Duct Plate Cubierta de la caja de la toma de corriente Tornillos de metal para l mina 8 x 3 8 Contenedor del bulbo con cableado Cubierta protectora del foco Paquete de tornillos tuercas incluye 2 tornillos 10 16 x 0 500 y 2 tuercas de metal de l mina 10 16 Navajas del abanico Tuercas 6 32 se ne
9. CTOR 13 Pase el cableado el ctrico a trav s del hueco de acceso perforado en la pared o la parte inferior del gabinete Suministre alambres de por lo menos 6 e instale el conector apropiado para el tipo de cable que est us ndose Quite la tuerca de traba del conector y deje que el cable preparado se proyecte a trav s del gabinete o abertura de pared de manera que est listo para instalarse dentro del extractor FIG 10 14 Posicione al extractor en su sitio de manera que a La l nea el ctrica pase a trav s de la abertura de quitar golpeando Este paso se puede conseguir mientras se posiciona el extractor FIG 13 b La parte m s grande de las ranuras en forma de hueco de cerradura en el extractor caben sobre los tornillos montantes que est n proyect ndose de la parte inferior del gabinete FIG 11 c El conector para el regulador ducto se desliza sobre los ductos en la pared o gabinete 15 Ajuste el extractor de manera que la parte frontal del extractor est a ras con la parte frontal del gabinete 16 Ajuste los cuatro tornillos para madera apret ndolos firmemente 17 Instale una tuerca de traba al conector el ctrico y apri telo 18 Haga la conexi n el ctrica usando tuercas de alambre para conectar el alambre blanco a blanco negro a negro Conecte el extractor a tierra a trav s del hueco preparado usando el tornillo verde suministrado FIG 12 19 Ponga la tapa de la caja del cableado y atornillela
10. FIG 3 NOTA Las rejillas que se encuentran al frente de la campana deben estar abiertas y visibles para que la campana funcione sin conducto 5 Quite la tapa de quitar golpeando el ctrica de arriba o atr s dependiendo en donde entra el cableado al extractor de la pared o del gabinete FIG 4 INSTALACION CON DUCTO SOLAMENTE NOTA La cubierta de las rejillas se debe instalar como se muestra en la figura 3 para que funcione con el conducto q 6 Quite la placa de quitar golpeando en el extractor insertando un destornillador en el filo y rompiendo las conexiones que lo sostienen al extractor Es posible que tenga que golpear el destornillador con un martillo para romper estas uniones Pele la tapa de quitar golpeando hacia atr s con una tenaza FIG 5 7 Junte el conector del regulador ducto sobre la aber tura y suj telo en su sitio con tornillos negros de metal para l mina FIG 6 Los pasadores de bisagra y el conector del regula dor ducto deben de estar hacia la parte de arriba del extractor para pasar el ducto a trav s de la pa red o hacia la parte de atr s del extractor para pa sar el ducto a trav s de gabinete encima del extractor Selle la uni n entre el conector regula dor ducto con cinta de ducto 8 S lo para descargas con conducto redondo de 7 Vuelva a instalar la placa del conducto redondo de 7 que quit en el paso 2 de la secci n PREPARAN DO EL EXTRACTOR
11. NS WILL FOLLOW THE PLANS MADE ON PAGE 2 START AT THE EX TERIOR AND RUN THE DUCT BACK TO THE RANGE HOOD FOR BEST PERFORMANCE OF YOUR RANGE HOOD USE THE SHORTEST POSSIBLE DUCT RUN AND A MINIMUM NUMBER OF ELBOWS NEVER VENT A RANGE HOOD INTO AN AT TIC SPACE BECAUSE A BUILDUP OF GREASE WILL BECOME A FIRE HAZARD USE ONLY METAL DUCTWORK DO NOT USE PLASTIC DUCT ASSEMBLE SECURELY SO THAT IN CASE OF A GREASE FIRE ON THE RANGE THE FIRE WILL BE CONTAINED IN SIDE METAL DUCT WORK IT IS A GOOD PRACTICE TO TAPE ALL DUCT CONNECTIONS MAKING THEM BOTH SE CURE AND AIR TIGHT 15 Follow appropriate directions below for type of duct work you are installing WALL CAPS FIG 9 Use a saber saw to cut a hole slightly larger than duct so duct will line up easily with hood Install casing strips on outside walls finished in siding Assemble the duct work and tape all joints Run l duct work back to hood Fasten wall cap to last section of duct and nail or screw cap to wall Seal all around flange on wall cap with caulking com pound Make sure that enough duct runs into the room so that the duct will overlap the damper duct connector by 3 4 when the hood is installed ROOF CAPS Cut hole in roof slightly larger than duct so duct will line up easily with hood Trim shingles around hole so that they will fit snugly around hood of cap when cap is installed Assemble the duct work and tape all joints Run the duct work down to
12. ONER CINTA EN TODAS LAS CONEXIONES DEL DUCTO HACI NDOLOS NO SOLAMENTE SEGUROS SINO TAMBI N A PRUEBA DE ESCAPE DE AIRE 15 Siga las direcciones apropiadas abajo para el tipo de ductos que est instalando CASQUETES DE PARED FIG 9 Use una sierra sable para cortar un hueco ligeramente m s grande que el di metro del ducto de manera que el ducto se alinee m s f cilmente con el extractor Instale tiras de sost n en las paredes exteriores que est n acabadas con superficie exterior de madera l aluminio o vinilo Ensamble los ductos y ponga cinta en todas las uniones Traiga los ductos de afuera hacia al extractor Sujete el casquete de pared a la ltima secci n de ducto y clave el casquete a la pared Selle alrededor de la ceja del casquete con un compuesto para rellenar Aseg rese que hay suficiente ducto que entra a la cocina de manera que el ducto sobrepasar y entrar dentro el conector de regulador ducto por lo menos por 3 4 cuando est el ducto instalado CASQUETES DEL TECHO Corte un hueco en el techo m s grande que el di metro del ducto de manera que el ducto se alinear m s f cilmente con el extractor Recorte el tejado tablillas de tejado alrededor de hueco de manera que quepan apretadamente alrededor de casquete cuando ste instalado Ensamble los ductos y ponga cinta aislante en todas las uniones Traiga el ducto hacia abajo al extractor Recorte el ducto paralelo a la inclinaci n del tech
13. RL6100F SERIES 4 WAY CONVERTIBLE RANGE HOOD READ AND SAVE THESE INSTRUCTIONS IMPORTANT For Non ducted Ductfree Installation a Purchase non ducted filter separately b Remove and discard damper duct connector and louver cover See Step 4 in Prepare the Hood Page 2 c Follow all steps except steps inside dotted lines For Ducted Installation Follow all steps including steps inside dotted lines WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR INJURY TO PERSONS OBSERVE THE FOLLOWING 1 Use this unit only in the manner intended by the manufacturer If you have questions contact the manufacturer at the address or telephone num ber listed in the warranty 2 Before servicing or cleaning unit switch power off at service panel and lock the service discon necting means to prevent power from being switched on accidentally When the service dis connecting means cannot be locked securely fasten a prominent warning device such as a tag to the service panel 3 Installation work and electrical wiring must be done by a qualified person s in accordance with all applicable codes and standards including fire rated construction codes and standards 4 Sufficient air is needed for proper combustion and exhausting of gases through the flue chimney of fuel burning equipment to prevent backdrafting Follow the heating equipment manufacturer s guideline and safety standards such as those pub lishe
14. cal connection in wall or cabinet 13 Hold hood up against cabinet bottom and trace keyhole slots onto cabinet bottom of filler strips 14 Screw the four supplied 7 8 wood screws for mounting the hood into the exact center of the narrow end of the keyhole slots marked under neath the cabinet Allow 3 8 of the screws to project so the hood can be fitted into place CUT STRIPS TO FIT CORTE LAS TIRAS PARA QUE QUEPAN CENTER LINE SPERIUPAPARA E CENTRICA LELDUCTO WIDTH OF RANGE HOOD ANCHO DEL EXTRACTOR ELECTRICAL WIRING OPENING ABERTURA PARA EL CABLEADO ELECTRICO PREPARANDO EL EXTRACTOR 1 Desempaque el extractor y revise el contenido de la caja Usted debe de encontrar 1 Filtro de aluminio 1 Conector de ducto regulador de 3 1 4 x 10 montado dentro del extractor para embarque solamente Guarde los tornillos para el montaje Placa del conducto redondo de 7 montado en del extractor no se muestra Guarde los tornillos para el montaje 2 Quite la placa del conducto redondo de 7 de la parte superior de la campana Col quela aparte con los tornillos de montaje 3 Quite la cubierta de la caja de cableado Bajo la tapa encontrar 1 Una bolsa de pl stico que contiene herrajes sueltos para instalaci n Para instalaciones sin ducto SOLAMENTE 4 Para instalaciones sin ducto quite la tapa de la reji llas de la parte frontal del extractor
15. cesitan 2 Soporte de montura del motor Conjunto del motor incluye piezas 6 7 y 8 Filtro de aluminio Filtro que no requiere ducto vendido separadamente Contenedor del filtro Tornillos de metal de cabeza hexagonal 8B x 1 4 se necesitan 2 Protecci n del regulador Forro de metal del regulador Ensamblado del regulador incluye piezas 13 y 14 R tulo Negra R tulo Blanca R tulo Beige Interruptor del motor de 2 velocidades Negra Interruptor del motor de 2 velocidades Blanca Interruptor del motor de 2 velocidades Beige Interruptor del foco Negra Interruptor del foco Blanca Interruptor del foco Beige Recipiente del motor con cableado Tapa de la rejillas Negra Tapa de la rejillas Blanca Tapa de la rejillas Almendra Tapa de la rejillas Beige Placa para conducto redondo de 7 Encargue piezas de servicio por NO PIEZA NO por NO CODIGO Piezas est ndar Se pueden comprar localmente NuTone Inc 4820 Red Bank Road Cincinatti OH 45227 1 800 543 8687 99043098B
16. d by the National Fire Protection Association NFPA and the American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE and the local code authorities 5 When cutting or drilling into wall or ceiling do not damage electrical wiring and other hidden utilities 6 Ducted fans must always be vented to the outdoors 7 Do not use this unit with any solid state speed control device 8 To reduce the risk of fire use only metal duct work 9 This unit must be grounded TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE 1 Never leave surface units unattended at high set tings Boilovers cause smoking and greasy spillovers that may ignite Heat oils slowly on low or medium settings 2 Always turn hood ON when cooking at high heat or when cooking flaming foods 3 Clean ventilation fans frequently Grease should not be allowed to accumulate on fan or filter 4 Use proper pan size Always use cookware ap propriate for the size of the surface element TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE OBSERVE THE FOLLOWING 1 SMOTHER FLAMES with a close fitting lid cookie sheet or metal tray then turn off the burner BE CAREFUL TO PREVENT BURNS If the flames do not go outimmediately EVACUATE AND CALLTHE FIRE DEPARTMENT 2 NEVER PICK UP A FLAMING PAN You may be burned 3 DO NOT USE WATER including wet dishcloths or towels a violent steam explosion will result 4
17. discharge only Re install 7 round duct plate removed in Step 2 under PRE PARING THE RANGE HOOD section For best performance line up the 7 round duct plate with the 7 round opening on hood Mount duct plate to hood with 2 screws from duct plate and 2 screws from 3 x 10 damper Install a 7 round damper purchase separately Damper flap must open freely in direction of air flow away from range hood 6 2 L PREPARING THE INSTALLATION LOCATION NOTE MOUNT HOOD SO THAT BOTTOM OF HOODIS 18 24 ABOVE COOKING SURFACE TOP FRONTEDGE OF HOOD SHOULD BE FLUSH WITH FRONT OF CABINET FRAME IF DISTANCE BETWEEN WALL AND FRONT OF CABINET FRAME IS MORE THAN 12 THERE WILL BE A SPACE BETWEEN BACK OF HOOD AND WALL THIS IS NORMAL OMIT STEP 9 if range hood will be installed under cabinets with flush bottom 9 Forinstallation on recessed bottom cabinets only Attach a wood filler strip at each side of recessed area under cabinet Use two 1 x 2 strips cut to length If recess is more than 1 use thicker strips Attach strips with 1 1 4 screws about 3 from each end See FIG 7 10 Measure and mark the following FIGS 7 amp 8 _2 Electrical line opening_______ _b Ductopening________ 11 Drill four pilot holes in corners of marked duct opening as shown and cut opening with saber saw or keyhole saw 12 Use 1 1 4 drill bit to drill opening for electri
18. eden apagar con bicarbonato de sodio o un extinguidor qu mico e Apague las hornillas si puede hacerlo sin quemarse GARANTIA NUTONE LIMITADA POR UN A O NuTone garantiza al consumidor comprador original de sus productos que dichos productos carecer n de defectos en materiales o en mano de obra por un per odo de un a o a partir de la fecha original de compra NO EXISTEN OTRAS GARANTIAS EXPLICITAS O IMPLICITAS INCLUYENDO PERO NO LIMITADAS A GARANTIAS IMPLICITAS DE COMERCIALIZACION O APTITUD PARA UN PROPOSITO PARTICULAR Durante el per odo de un a o y a su propio criterio NuTone reparar o reemplazar sin costo alguno cualquier producto o pieza que se encuentre defectuosa bajo condiciones normales de servicio y uso ESTA GARANTIA NO SE APLICA A TUBOS Y ARRANCADORES DE LAMPARAS FLUORESCENTES Esta garant a no cubre a mantenimiento y servicio normales o b cualquier producto o piezas que hayan sido utilizadas de forma err nea negligente que hayan causado un accidente o que hayan sido reparadas o mantenidas inapropiadamente por otras compa as que no sean NuTone instalaci n defectuosa o instalaci n contraria a las instrucciones de instalaci n recomendadas La duraci n de cualquier garant a impl cita se limita a un per odo de un a o como se especifica en la garant a expresa Algunos estados no permiten limitaciones en cuanto al tiempo de expiraci n de una garant a impl cita por lo que la limitaci n antes menci
19. f requesting warranty service you must present evidence of the original purchase date NuTone Inc 4820 Red Bank Road Cincinatti OH 45227 1 800 543 8687 COMO EVITAR QUE OCURRA UN INCENDIO DEBIDO A LA GRASA QUE SE ACUMULA EN UN EXTRACTOR COMUN e Su extractor proporciona una barrera protectora entre la superficie para cocinar y los gabinetes Mantenga el abanico los filtros y las superficies donde se acumula la grasa LIMPIAS conforme a las instrucciones ENCIENDA siempre el extractor cuando est cocinando a fuego alto para mantener el area para cocinar y el extractor limpios Utilice las hornillas de fuego alto solamente cuando sea necesario No deje las hornillas de la estufa sin atenci n cuando est cocinando El vapor o el aceite que salpique puede ocasionar un incendio o acumulaci n de humo e Siempre utilice los utensilios del tama o adecuado e Si est preparando alimentos flameados como las Cerezas a la Jubilee ENCIENDA siempre el ex tractor en ALTO para evitar que el calor pueda causar alg n da o o un incendio COMO EXTINGUIR UN INCENDIO EN UN EXTRAC TOR COMUN e No levante nunca una sart n que est en llamas Si se le cae las llamas se pueden extender rapidamente NO UTILICE AGUA PARA APAGARLO Puede ocasionar una explosi n de vapor Las toallas de cocina mojadas tambi n son peligrosas e Ahogue las llamas con una tapa ajustada o una charola Las llamas provocadas por la grasa tambi n se pu
20. hood Trim duct parallel to roof pitch leaving 3 4 of duct projecting above roof Seal all around duct with roof cement Install roof cap inserting back edge of cap under shingles Seal around cap with roof cement and seal all nail heads and shingles which were cut or lifted Make sure that enough duct runs into the room so that the duct will overlap the damper duct connec rd by 3 4 when the hood is put into place 1 3 1 4 x 10 DUCT DUCTO DE 3 1 4 x 10 FRONT OF CABINET PARTE FRONTAL DEL GABINETE ne Tag ls imam 51 41 HORIZONTAL DUCTING AND WIRING Through Wall DUCTOS YALAMBRES PARACONEXION HORIZONTAL Atrav s de la pared TM A CABINET BOTTOM GABINETE 678 71 i E Men 514 al Meza VERTICAL DUCTING AND WIRING BACKWALL Through Cabinet Bottom PAREDTRASERA DUCTOS Y ALAMBRES PARA CONEXION VERTICAL A trav s de la parte inferior del gabinete 7 ROUND DUCT DUCTO REDONDO DE 7 F CABINET FRONT FRENTE DEL GABINETE a T 755 CABINET BOTTOM FONDO DEL GABINETE 8 DIA ACCESS HOLE 9 ORIFICIO DE ACCESO 8 DE DI ELECTRICAL ACCESS HOLE G in cabinet bottom WOOD SHIMS recessed bottom cabinets only CUNAS DE MADERA s lo gabinetes de fondo empotrado ORIFICIO DE ACCESO PARA LOS CABLES ELECTRICOS en el fondo del gabinete WALL CAP TAPADE PARED PREPARANDO LA UBICACION DE LA INSTALACION CONT 10 Mida y marque lo siguiente
21. io y asegure el panel de servicio para evitar que se encienda accidentalmente Cuando el dispositivo para desconectar el servicio el ctrico no puede ser cerrado con alg n tipo de traba sujete fuertemente al panel de servicio una etiqueta de advertencia prominente 3 Todo trabajo de instalaci n y cableado el ctrico debe ser realizado por personal calificado y de acuerdo con todos los c digos y normas pertinentes incluyendo los c digos y normas relacionados con construcci n clasificada para incendio 4 Aire suficiente es necesario para facilitar la combusti n adecuada y la salida apropiada de gases por la chimenea de la unidad y para evitar corrientes de aire invertidas Siga las instrucciones y medidas de seguridad del fabricante del equipo y de las sociedades profesionales de equipos de calentadores y los reglamentos de seguridad locales 5 Acortar o perforar la pared o el techo no da e el cableado el ctrico u otros servicios p blicos ocultos a la vista 6 Los abanicos con ducto deber n siempre tener una salida hacia el exterior 7 No utilice esta unidad en conjunto con cualquier dispositivo de control de velocidad de estado s lido 8 Para reducir el riesgo de incendio use s lo ductos de metal 9 Esta unidad se debe instalar con tierra efectiva PARA REDUCIR EL RIESGO DE UN INCENDIO POR GRA SA EN EN LA ESTUFA 1 Nunca deje sin atender las unidades de superficie cuando tengan ajustes altos Los reboses pueden
22. la pared exterior Si se usa un casquete de pared directamente en la parte de atr s del extractor hay que asegurarse que el regulador en el conector entre ducto y regulador en el extractor y el regulador en el casquete de pared no interfieran el uno con el otro cuando el extractor est operando Esto podr a resultar en paso de aire inadecuado o corrientes invertidas Si esta condici n existe quite la hoja instalada en el regulador del extractor Aveces cuando se usa un casquete de pared es m s f cil pasar el ducto verticalmente y usar un codo como se muestra en FIG 1B FIG 1C Haciendo un ducto directamente al techo usando un ducto rectangular de 3 1 4 x 10 para instalaciones en un piso solamente FIG 1D Instalando un ducto entre las vigas del techo para instalaciones en m s de un piso o a trav s del espacio de sofito arriba de los gabinetes cuando el sofito est conectado a una pared exterior FIG 1E Directamente hacia el techo usando transici n de 3 1 4 x 10 a un ducto redondo de 6 y ducto redondo de 6 para instalaciones de un piso FIG 1F Directamente hacia el techo usando ducto redondo de 7 para instalaciones de un piso PREPARING THE RANGE HOOD f Unpack hood and check contents You should receive 1 Aluminum Filter 1 3 1 4 x 10 Damper Duct Connector mounted inside of hood for shipping only Save screws for mounting 1 7 Round Duct Plate mounted on top of hood not sh
23. mo de abajo de la grampa sostiene un solo filtro firmemente en su sitio FIG 13 En la versi n que no requiere ducto ponga ambos el filtro de aluminio y el filtro que no requiere ducto bajo las grampas en la parte de atr s del bastidor del ventilador D la vuelta a los sostenes retentores de manera que el extremo alto sostiene ambos filtros firmemente en su sitio Aseg rese que el filtro que no requiere ducto est m s cerca al ensamblaje del ventilador con el lado azul a lado de las aspas del ventilador y el filtro de aluminio quede hacia afuera NOTESE Aseg rese que las flechas en el punto donde se pone las grampa retentoras apunten hacia atr s a la parte frontal del extractor REEMPLAZO DEL BOMBILLO DE LUZ El bombillo de luz que no viene con el extractor deber a de ser de un m ximo de 75 vatios El vidrio lente que cubre el bombillo se quita pellizcado los dos sostenes que se extienden hasta que se salen de sus ranuras retentoras FIG 14 COMO QUITAR EL ENSAMBLAJE DEL VENTILADOR Aseg rese que la potencia el ctrica est desconectada Quite los filtros Quite los dos tornillos que sostienen el sost n del motor al extractor y desenchufe el ensamblaje de ventilador Tenga cuidado que no permita que el ensamblaje del ventilador se caiga cuando se quiten los tornillos FIG 15 HOW TO AVOID A COMMON RANGE TOP GREASE FIRE e Your range hood provides a protective barrier between the cooking surface and the cabine
24. o dejando 3 4 de ducto que se proyecte m s arriba de techo Selle la abertura alrededor de ducto con cemento de techo Instale el casquete insertando el filo de atr s de la ceja del casquete debajo de las tablillas del tejado Selle alrededor del casquete con cemento de techo y selle todas las cabezas de clavos y tablillas que fueron cortadas o levantadas Aseg rese que haya suficiente ducto que se proyecte dentro la cocina de manera que el ducto sobrepase al conector de regulador ducto por 3 4 cuando el extrac tor est en su sitio A a a 1 INSTALLING THE RANGE HOOD 16 Bring electrical cable through access hole drilled in wall or bottom of cabinet Provide 6 wire leads and install proper connector for type of cable be ing used Remove lock nut from connector and let prepared cable project through cabinet or wall opening so it is ready for installation into range hood FIG 10 17 Position hood in place so that a Electrical line is routed through appropriate knockout opening This step will have to be accomplished while positioning hood FIG 13 b Large part of keyhole mounting slots on hood fit onto hood mounting screws projecting from bottom of cabinet FIG 11 c Damper duct connector slides into duct work in wall or cabinet 18 Adjust hood so the front of hood is flush with cabinet front 19 Tighten the four hood mounting screws securely 20 Install locknut on electrical connector and tighten
25. o o trinquete Broca tipo pala de 1 1 4 Destornillador de ranura o tipo phillips Pinzas o tenazas Medidor de cinta o regla y l piz mE mi m a m a m A Sierra tipo sable o sierra para tabiques LH Alicate para cortar J MATERIALES 1 Suministros y alambre el ctrico del tipo que cumplen con los c digos locales TU Casquete de techo o pared A 1 Cemento o pega de techa o material de calafatear o rellenar L7 Ductos y cinta aislante para ductos J Para instalaci n en gabinetes de cocina con la parte infe rior ahuecada solamente A Dos tiras de madera 1 x 2 x 12 largo aproximado c mpreselas localmente A Cuatro tornillos para madera de cabeza plana de 1 1 4 de largo c mpreselas localmente para sujetar las tiras de madera a la parte inferior de gabinete PLANIFICANDO LA INSTALACION DE LOS DUCTOS Comience el trabajo de los ductos decidiendo el camino que el ducto tomar entre el extractor y la parte exterior de la casa Para mejor rendimiento use el camino de ducto m s corto posible y un m nimo de codos Se muestran varias elecciones FIGS 1A 1E En situaciones de paso del ducto m s complejas el ex tractor con conexi n para ducto rectangular puede convertirse en conexi n redonda usando una transici n FIG 1A Pasando el ducto directamente a trav s de la pared para los extractores que est n instalados en una pared exterior Se muestran dos maneras de pasar el ducto a trav s de
26. oduct or part which is found to be defective under normal use and service THIS WARRANTY DOES NOT EXTEND TO FLUORESCENT LAMP STARTERS AND TUBES This warranty does not cover a normal maintenance and service or b any products or parts which have been subject to misuse negligence accident improper maintenance or repair other than by NuTone faulty installation or installation contrary to recommended installation instructions The duration of an implied warranty is limited to the one year period as specified for the express warranty Some states do not allow limitation on how long an implied warranty lasts so the above limitation may not apply to you NUTONE S OBLIGATION TO REPAIR OR REPLACE AT NUTONE S OPTION SHALL BE THE PURCHASER S SOLE AND EXCLUSIVE REMEDY UNDER THIS WARRANTY NUTONE SHALL NOT BE LIABLE FOR INCIDENTAL CONSEQUENTIAL OR SPECIAL DAMAGES ARISING OUT OF OR IN CONNECTION WITH PRODUCT USE OR PERFOR MANCE Some states do not allow the exclusion or limitation of incidental or consequential damages so the above limitation may not apply to you This warranty gives you specific legal rights and you may also have other rights which vary from state to state This warranty supersedes all prior warranties To qualify for warranty service you must a notify NuTone at the address or telephone number below b give the model number and part identification and c describe the nature of any defect in the product or part At the time o
27. of elbows There are several choices shown FIGS 1A 1E In more complex ducting situations a 3 1 4 rectan gular ducting range hood can be converted to a round duct by means of a transition FIG 1A Ducting directly through the wall for range hoods mounted on an exterior wall Shown are two ways to duct through an outside wall If a wall cap is used directly off the back of the hood special care must be taken to make sure that the damper in the damper duct connector on the hood and damper in the wall cap do not interfere with each other when the hood is operating This could result in either inadequate air delivery or back drafts If this condition does exist remove the hood damper flap Sometimes when us ing a wall cap it is easier to duct vertically and then use an elbow as shown in FIG 1B FIG 1C Ducting straight up through the roof using 3 1 4 x 10 rectangular duct For single story in stallations FIG 1D Ducting between the ceiling joists for multi story installations or through the soffit space above the cabinets where the soffit connects to an outside wall FIG 1E Straight up through the roof using 3 1 4 x 10 to 6 round duct transition and 6 round duct for single story installations FIG 1F Straight up through the roof using 7 round duct for single story installations FIG 1A WALL CAP CASQUETE DE PARED WALL CAP CASQUETE DE PARED 3 1 4 x 10 DUCT DUCTO DE 3 1 4 x 10
28. onada puede no aplicarse a usted LA OBLIGACION DE NUTONE DE REPARAR O REEMPLAZAR SIGUIENDO EL CRITERIO DE NUTONE DEBERA SER EL UNICO Y EXCLUSIVO RECURSO LEGAL DEL COMPRADOR BAJO ESTA GARANTIA NUTONE NO SERA RESPONSABLE POR DANOS INCIDENTALES CONSIGUIENTES O POR DANOS ESPECIALES QUE SURJAN A RAIZ DEL USO O DESEMPENO DEL PRODUCTO Algunos estados no permiten la exclusi n o limitaci n de da os incidentales o consiguientes por lo que la limitaci n antes mencionada puede no aplicarse a usted Esta garant a le proporciona derechos legales espec ficos y usted puede tambi n tener otros derechos los cuales var an de estado a estado Esta garant a reemplaza todas las garant as anteriores Para calificar en la garant a de servicio usted debe a notificar a NuTone al domicilio o n mero de tel fono abajo b dar el n mero del modelo y la identificaci n de la pieza y c describir la naturaleza de cualquier defecto en el producto o pieza En el momento de solicitar servicio cubierto por la garant a usted debe de presentar evidencia de la fecha original de compra NuTone Inc 4820 Red Bank Road Cincinatti OH 45227 1 800 543 8687 SERVICE PARTS RL6100F SERIES RANGE HOOD PARTES DE SERVICIO SERIE RL6100F CAMPANA EXTRACTORA A AE NO conico NO PIEZ DESCRIPTION DESCRIPCION 98006621 99170245 99270987 99110437 97011217 99020272 99260428 98005568 97012248 K7589 K7588 99420472 99150415 SENO NAN
29. own Save screws for mounting 2 Remove 7 round duct plate from top of hood Set duct plate aside with mounting screws 3 Remove wiring box cover Under cover find 1 Plastic Bag containing loose mounting hardware For Ductfree Installations Only 4 Forductfree installation remove louver cover from front or inside of hood FIG 3 NOTE Louvers on front of hood must be open and visible for hood to function in ductfree mode 5 Remove either top or rear electrical knockout de pending upon whether wiring will enter hood from wall or cabinet FIG 4 KEYHOLE SLOTS RANURAS EN FORMA DE HUECO DE CERRADURA WIRING BOX COVER TAPADE LA CAJA DE ALUMINUM FILTER CABLEADO FILTRO DE ALUMINIO DAMPER DUCT CONNECTOR CONECTOR AL REGULADOR DUCTO NOTE Louver cover must be installed as shown in Figure 3 to function in ducted mode Remove appropriate duct knockout on hood by inserting screwdriver into edge of knockout and breaking tabs holding knockout to hood You may have to tap screwdriver with hammer to break tabs Peel knockout back with pliers FIG 5 Fit damper duct connector over opening and secure in place with black sheet metal screws FIG 6 Hinge pins and damper duct connector should be toward top of hood for ducting through wall or toward back of hood for ducting through cabinet above hood Seal joint between damper duct con nector and hood with duct tape 7 round ducted
30. provocar humo y derrames grasosos que se pueden incendiar Caliente lentamente el aceite en un ajuste bajo o medio 2 Siempre ENCIENDA la campana cuando cocine con alta temperatura o cuando cocine alimentos que se puedan incendiar 3 Limpie con frecuencia los ventiladores No debe permitir que la grasa se acumule en el ventilador ni en el filtro 4 Utilice un sart n de tama o adecuado Siempre utilice el utensilio adecuado al tama o del elemento de superficie PARA REDUCIR EL RIESGO DE LESION A PERSONAS RESULTADO DE UN INCENDIO DEBIDO A GRASA ACU MULADA EN LAS HORNILLAS PROCURE LO SIGUIEN TE 1 AHOGUE LAS LLAMAS con una tapa ajustada o charola de metal despu s apague la hornilla TENGA CUIDADO A FIN DE EVITAR QUEMADURAS Si las llamas no se apagan de inmediato EVACUE Y AVISE A LOS BOMBEROS 2 NO LEVANTE NUNCA UNA SARTEN QUE ESTE EN LLAMAS Usted se podr quemar 3 NOUTILICEAGUA incluyendo toallas de cocina mojadas puede resultar una explosi n de vapor violenta 4 Utilice un extinguidor SOLAMENTE si A Usted sabe que tiene un extinguidor de clase ABC y lo sabe utilizar B El incendio es peque o y contenido dentro del rea donde se inici C Los bomberos han sido avisados D Usted puede combatir el incendio con una salida a su espalda Basado en las recomendaciones para Seguridad en la Cocina publicadas por la NFPA de los EEUU CAUTION 1 Forgeneral ventilating use only Do not use to exha
31. ts Keep fan filters and grease laden surfaces CLEAN according to instructions Always turn hood ON when cooking at high heat to keep the cooking area and the hood cooler Use high heat settings only when necessary Never leave cooking surface unattended Boil over causes smoking and greasy spillovers that may ignite Always use adequate sized utensils If preparing flaming foods such as Cherries Ju bilee always turn hood ON to HIGH to prevent a high heat situation which can cause damage or fire HOW TO EXTINGUISH A COMMON RANGE TOP GREASE FIRE e Never pick up a flaming pan If dropped flames can spread quickly DO NOT USE WATER A violent steam explo sion may result Wet dishcloths or towels are also dangerous Smother flames with a close fitting lid cookie sheet or metal tray Flaming grease can also be extinguished with baking soda or a multi purpose dry chemical extinguisher Turn off surface units if you can do so without getting burned NUTONE ONE YEAR LIMITED WARRANTY NuTone warrants to the original consumer purchaser of its products that such products will be free from defects in materials or workmanship for a period of one year from the date of original purchase THERE ARE NO OTHER WARRANTIES EXPRESS OR IMPLIED IN CLUDING BUT NOT LIMITED TO IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE During this one year period NuTone will at its option repair or replace without charge any pr
32. ust hazardous or explosive materials and vapors 2 To avoid motor bearing damage and noisy and or unbalanced impellers keep drywall spray construction dust etc off power unit 3 Your hood motor has a thermal overload which will automatically shut off the motor if it becomes overheated The motor will restart when it cools down If the motor continues to shut off and restart have the hood serviced 4 For best capture of cooking impurities your range hood should be mounted 18 24 above the cooking surface 5 Please read specification label on product for further information and requirements TOOLS AND MATERIALS REQUIRED TOOLS A Drill electric or ratchet drive A 1 1 4 Spade bit 1 Common head and phillips head screwdriver A Pliers Id Tape measure or ruler and pencil A Saber saw or drywall saw LH Metal snips J MATERIALS A Electrical wiring and supplies of type to comply with local codes TO Rooforwalleap 0 O Roof cement or caulk A Duct and duct tape For Installation on Kitchen Cabinets with Recessed Bottoms Only A Two 1 x2 x 12 approximate length wood strips purchase locally A Four1 1 4 long flat head wood screws purchase locally to fasten strips to cabinet bottom PLANNING DUCTWORK INSTALLATION Begin planning ductwork by deciding where the duct will run between the range hood and the outside For best performance use the shortest possible duct run and a minimum number
Download Pdf Manuals
Related Search
Related Contents
Oferta Especial De Repuestos Para La Campaña Guia do Usuário da Impressora para Grandes Formatos Xerox 6030 CONDICIONES DE VENTA Y GARANTIAS Snapper 2418 User's Manual R&D,製造用融着接続機 (PDF 539KB) Instructions dépistage du cancer colorectal conseils clés pour la bonne Mode d`emploi klicken - Corel Corporation Copyright © All rights reserved.