White Rodgers 1F83-0471 Thermostat User Manual

image

Contents

1. If a voltage spike or static discharge blanks out the display or causes erratic thermostat operation you can reset the thermostat by removing the wires from terminals R and C do not short them together and removing batteries for 2 minutes After resetting the thermostat replace the wires and batteries If the thermostat has been reset and still does not function correctly contact your heating cooling service person or place of purchase Note Be sure to review the installer configuration menu settings To reset the programming clock and configuration settings press and and the FAN button simultaneously The thermostat should go blank and then all segments will be displayed momentarily Symptom No Heat No Cool No Fan common problems No Heat No Cool Heat Cool or Fan Runs Constantly Thermostat Setting amp Thermostat Thermometer Disagree Furnace Air Conditioner Cycles Too Fast or Too Slow narrow or wide temperature swing White Rodgers is a division of Emerson Electric Co The Emerson logo is a trademark and service mark of Emerson Electric Co Possible Cause Blown fuse or tripped circuit breaker Furnace power switch to OFF Furnace blower compartment door or panel loose or not properly installed Loose connection to thermostat or system Pilot light not lit Furnace Lock Out Condition Heat may also be intermittent Heating system requires service or thermostat requires rep
2. There may be up to a five minute delay before the thermostat clicks in Cooling Check each wire connection to verify they are not shorted or touching together No bare wire should stick out from under terminal block Try resetting the thermostat as described above If the condition persists the manufacturer of your system or service person can instruct you on how to test the Heat Cool system for correct operation If the system operates correctly replace the thermostat The thermometer can be adjusted 4 degrees See Temperature Display Adjustment in the Configuration Menu section Digital thermostats provide precise control and cycle faster than older mechanical models The system turns on and off more frequently but runs for a shorter time so there is no increase in energy use If you would like an increased cycle time choose SL for slow cycle in the Configuration menu step 6 heat 7 cool or 8 heat pump If an acceptable cycle rate is not achieved contact a local HVAC service person for additional suggestions HOMEOWNER HELP LINE 1 800 284 2925 White y amp Rodgers St Louis Missouri EMERSON www white rodgers com
3. AA batteries Set O TETE indicates good power level D ml indicates batteries at about _ half power Change MT_ gt indicates FETE B j t O batteries are low and should be Q replaced with 2 new premium brand D l AA Alkaline batteries fN See page 2 for more details SYSTEM if FAN i Heat Auto Menu 7 System Fan Indicator Indicator Figure 4 Programming amp Configuration Items Mo TuliWe Th Fr Sa Su a 08 JA Change HIE Filter G System On 2 f 9 Heat Pump P Date mh yt mim Temp Hold Month Call For Service set U Dara O Year Save i D i a Hold 10 Auto Sched G 1 INI AY E Savings s SYSTEM AN Run Heat Emer Auto 7 Auto Schedule Cool Off Time Run Sched Menu Programming and Configuration Items OO O System On indicates when heating or cooling stage is energized System On 2 indicates when a second stage is energized The word HOLD is displayed when the thermostat is in the HOLD mode Temp HOLD is displayed when the thermostat is in a Temporary HOLD mode Displays Change Filter when the system has run for the programmed filter time period as a reminder to change or clean your filter Displays Set for setpoint when in Run Program mode Displays System Mode Heat Emer Auto Cool Off or Time in menu mode Displays Fan Mode
4. Mode Configuration This thermostat is config ured for Heat and Cool SYSTEM switch with Cool Off Heat default It can also be configured for Heat and Cool with Auto changeover Heat Auto Cool Off Heat only with fan Off Heat Heat only without fan Auto only Auto Off and Cool only Cool Off 10 Select Backlight Display The display backlight improves display contrast in low lighting conditions When the C terminal is powered selecting backlight CdL ON will keep the light on continuously Select backlight OFF will turn the light on momentarily after any key is pressed When the C terminal is not powered the light will be on momen tarily after any key is pressed no matter whether the backlight is selected ON or OFF 11 Select Temperature Display Adjustment 4 LO to 4 HI Allows you to adjust the room temperature display up to 4 higher or lower Your thermostat was accurately calibrated at the factory but you have the option to change the dis play temperature to match your previous thermostat The current or adjusted room temperature will be displayed 12 Select F or C Readout Changes the display readout to Centigrade or Fahrenheit as required 13 Program Options 1F85 only configured for 5 1 1 day or 5 2 day programming or non programming mode The default setting is P2 indicating 5 2 day programming The programs per can be toggled to P3 or PO by pressing the CA or CY keys A selection
5. On Auto or Run Sched in Menu mode T 7 Displays Run Schedule Schedule or Menu Displays Save when Cool Savings is working Displays Heat Pump when system is configured as Heat Pump thermostat Displays Hold in programmable mode when not in Hold mode Displays Light Bulb in non programmable mode 4 Initially displays Auto Sched If Auto Schedule had been used or disabled then it displays Cool Savings when in the Cool Mode Call For Service indicates a fault in the heating cooling system it does not indicate a fault in the thermostat INSTALLER CONFIGURATION MENU Press the Menu button for at least 5 seconds The display will show item 1 in the table below Press Menu to advance to the next menu item Press or Cv to change a menu item Shaded items available on 1 85 model only INSTALLER CONFIGURATION MENU MENU PRESS DISPLAYED Press or to REF BUTTON FACTORY DEFAULT select from listed options COMMENTS 1 1 1 MENU MS 2 HP 1 HP 2 SS 1 Selects Multi Stage MS 2 No Heat Pump Heat Pump 1 HP 1 1 compressor Heat Pump 2 HP 2 2 compressor or 2 speed compressor or Single Stage SS 1 2 2 2 MENU GAS for SS or MS ELE GAS setting furnace controls the blower ELE for HP ELE setting thermostat controls the blower 3 3 3 MENU CS 3 1 2 4 5 6 Selects Cool Savings Value 1 low to 6 high 4 4 4 MENU E On OFF Selects Energy Management Recovery EMR On o
6. Remove Old Thermostat A standard heat cool thermostat consists of three basic parts 1 The cover which may be either a snap on or hinge type 2 The base which is removed by loosening all captive screws 3 The switching subbase which is removed by unscrewing the mounting screws that hold it on the wall or adapter plate Before removing wires from old thermostat label each wire with the terminal designation from which it was attached Disconnect the wires from the old thermostat one at a time Do not let wires fall back into the wall Installing New Thermostat 1 Pull the thermostat body off the thermostat base Forcing or prying on the thermostat will cause damage to the unit Place base over hole in wall and mark mounting hole locations on wall using base as a template Move base out of the way Drill mounting holes If you are using existing mounting holes and the holes drilled are too large and do not allow you to tighten base snug ly use plastic screw anchors to secure the base Fasten base snugly to wall using mounting holes shown in Figure 2 and two mounting screws Leveling is for appearance only and will not affect thermostat operation Connect wires to terminal block on base Push excess wire into wall and plug hole with a fire re sistant material such as fiberglass insulation to prevent drafts from affecting thermostat operation Carefully line the thermostat up with the base and snap into place Bat
7. slightly higher temperature feel more comfortable Cool Savings operates during periods of high demand which normally occur onthe hottest summer days when a cooling system may run for hours to reach the thermostat setting Long cooling run times also lower the indoor humidity Cool Savings very slowly adjusts the setpoint temperature to make the setpoint closer to the displayed room temperature to a maximum of the number of degrees you select Adjusting the setpoint temperature over a long cooling run time allows the system to reach your set temperature and turn off The room temperature will actually be higher than the thermostat displays but the reduction in humidity will allow comfort at the slightly higher temperature To turn this feature on in the Cool mode press Cool Sav ings The display will show Save next to the setpoint temperature When Cool Savings is making adjustments to the room temperature display Save will be flashing and the displayed room temperature may vary within the adjust ment range you selected If Save is not displayed and this feature is OFF no change will occur when the cooling system is continuously running during periods of high demand Energy Management Recovery this step is skipped if configured to be non programmable Energy Management Recovery E On enables the ther mostat to start heating or cooling early to make the building temperature reach the program setpoint at the time you spe
8. White y Rodgers Save these instructions for future use FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE PERSONAL INJURY AND OR PROPERTY DAMAGE APPLICATIONS THERMOSTAT APPLICATION GUIDE Description Heat Pump No Aux or Emergency Heat Heat Pump with Aux or Emergency Heat Systems with up to 3 Stages Heat 2 Stages Cool Heat Only Systems with optional fan switch Millivolt Heat Only Systems Floor or Wall Furnaces g Cool Only Systems Gas or Oil Heat Electric Furnace Hydronic Hot Water Zone Heat 2 Wires Hydronic Hot Water Zone Heat 3 Wires SPECIFICATIONS Electrical Rating Battery Power Input Hardwire Terminal Load Setpoint Range 00 eee ee Differential Single Stage Differential Heat Pump Operating Ambient Operating Humidity Shipping Temperature Range Dimensions Thermostat Heat Pump No Aux or Emergency Heat Heat Pump with Aux or Emergency Heat Systems with up to 3 Stages Heat 2 Stages Cool Heat Only Systems with optional fan switch Yes _ Milivott Heat Only Systems Floor or Wall Furnaces Cool Only Systems oo Gas or Oil Heat o Electric Furnace oo g To prevent electrical shock and or equipment damage disconnect electric power to system at main fuse or circuit breaker box until installation is complete Operating Your Thermostat 6 Programming y 6 Troubleshootin
9. anning Your Program Important The Heating and Cooling Program schedules below allow you to pencil in your own program times and temperatures The 1F85 0471 comes configured for 5 1 1 day programming and can also be configured for 5 2 day programming see configuration section Factory settings are listed on Monday through Friday Saturday and Sunday If you are re programming a 5 2 day schedule pencil in your own times and temperatures directly below the factory times and temperatures If you are re programming a 5 1 1 fill in all lines with the times and temperatures you want Keep the following guidelines in mind when planning your program e In Heating lower temperatures will save energy e In Cooling higher temperatures will save energy e If you plan on using Auto Changeover do not program the heating higher than the cooling Worksheet for Re Programming 5 2 Day and 5 1 1 Day Program Heating Wake Up Leave For Work Return Home Go To Bed Program Period 1 Period 2 Period 3 Period 4 6 00 AM 8 00 AM 5 00 PM 10 00PM 62 F a 6 00 AM 8 00 AM 5 00 PM 10 00 PM 62 F 6 00 AM 8 00 AM 5 00 PM 10 00PM 62 F Cooling Wake Up Leave For Work Return Home Go To Bed Program Period 1 Period 2 Period 3 Period 4 6 00 AM 78 F ee ee ee va 6 00 AM 78 F 6 00 AM 78 F TROUBLESHOOTING Reset Operation Note When thermostat is reset installer configuration menu settings and programming will reset to factory settings
10. cify Heating will start 5 minutes early for every 1 of temperature required to reach setpoint Example E On is selected and your heating is pro grammed to 65 at night and 70 at 7 AM If the building temperature is 65 the difference between 65 and 70 is 5 Allowing 5 minutes per degree the thermostat setpoint will change to 70 at 6 35 AM Cooling allows more time per degree because it takes longer to reach set temperature 5 6 amp 7 Cycle Rate Selection The factory default setting for 8 Heat and Cool modes SS1 MS2 is medium cycle ME For Heat Pump HP1 HP2 the default setting is medium ME For Emer Aux the default setting is fast cycle FA To change cycle rate press the or key Cycle rate differentials for different settings are Fast Medium Slow MODE FA ME SL Heat SS1 MS2 0 4 F 0 6 F 1 7 F Cool SS1 MS2 0 9 F 1 2 F 1 7 F Heat Pump HP1 HP2 0 9 F 1 2 F 1 7 F Emer HP1 HP2 0 6 F 1 7 F Select Compressor Lockout CL OFF or ON Selecting CL ON will cause the thermostat to wait 5 minutes between cooling cycles This is intended to help protect the compres sor from short cycling Some newer compressors already have a time delay built in and do not require this feature Your compressor manufacturer can tell you if the lockout feature is already present in their system When the thermostat compressor time delay occurs it will flash the setpoint for up to five minutes System
11. e 1st heating period 5 Press Time button time will flash 6 Press or CY key to adjust the start time for the 1st period 7 The time will change in 15 minute increments 8 After you have set the time and the temperature for the period to begin press Schedule to advance to the next program period 9 Repeat steps 2 through 8 until all of the program times and temperatures are set for all program periods on that day 10 Press Schedule to the next day and repeat steps 2 through 9 11 When programming is complete and all of the times and temperatures match your desired heating schedule press Run Schedule The thermostat will now run your program Enter the Cooling Program 1 Press SYSTEM button to select Cool in the system switch area indicating the active mode being pro grammed 2 Follow Enter Heating Program instructions for entering cooling times and temperatures PROGRAMMING For Programmable Model Only Energy Saving Factory Pre Program The 1F85 0471 thermostats are programmed with the energy saving settings shown in the table below for all days of the week If this program suits your needs simply set the thermostat clock and press the RUN Sched button The table below shows the factory set heating and cooling schedule for all days of the week Wake Up Leave For Work Go To Bed Period 1 Period 2 Period 3 i Heating r Program 6 00 AM 8 00 AM 5 00 PM 10 00 PM Cooling Program 6 00 AM 15 F 8 00 AM Pl
12. e option On or OFF 1F85 only MENU Change Filter OFF O Selects Filter Change out Indicator On or OFF MENU Change Filter 200 h 25 1975 h Change Filter time in 25 hour increments This menu only appears if On is selected in above MENU Cool On o Heat On b Selects operation of the reversing valve terminal O B output as an O or B terminal RUN Returns to Normal Operation SCHED O m m mi Z Z Z e C OFF OFF OFF OFF OFF n O 7 N a a S N Oo w NM N ia sas O CO N OJ JAJO 5 0 O1 gt D INSTALLER CONFIGURATION MENU 1 This control can be configured for MS 2 Multi Stage System no heat pump HP 1 Heat Pump with one stage of compressor HP 2 Heat Pump with two stage compressor or two compressor system Gas or Electric backup SS 1 Single Stage System GAS or Electric ELE fan operation If the heating system requires the thermostat to energize the fan select ELE Select GAS if the heating system energizes the fan on a call for heat Select Cool Savings value Selects the amount of adjustment for the Cool Savings feature in Cool mode with 1 1 being the least amount of adjustment and 6 6 being the most amount of adjustment Default value is 3 Cool Savings is an optional energy saving feature that can reduce your cooling costs It is based on the principal that lower indoor humidity makes a
13. eature OFF 19 Select Filter Replacement Reminder and Set Run Time Select the Change Filter reminder On or OFF If selec ted On press MENU to select the time period from 25 to 1975 hours in 25 hours increments In a typical system 200 hours default of run time is approximately 30 days After the selected time of blower operation the thermostat will display Change Filter as a reminder to change or clean your air filter When Change Filter is displayed press MENU or RUN SCHED button to clear the display and restart the time to the next filter change 20 Select Reversing Valve Output The O B option is factory set at O position This will accommodate the majority of heat pump applications which require the changeover relay to be energized in COOL If the thermo stat you are replacing or the heat pump being installed with this thermostat requires a B terminal to energize the changeover relay in HEAT the O B option should be set at B position 5 OPERATING YOUR THERMOSTAT Choose the Fan Setting Auto or On Set the FAN Switch to Auto or On Fan Auto is the most commonly selected setting and runs the fan only when the heating or cooling system is on Fan On runs the fan continuously for increased air circulation or to allow additional air cleaning Choose the System Setting Heat Off Cool Auto Emer Press the SYSTEM button to select Heat Thermostat controls only the heating system Off Hea
14. g Ta aa te lt gt EMERSON www white rodgers com 80 Series Thermostat with Automatic Heat Cool Changeover Option Single Stage Multi Stage or Heat Pump Installation and Operating Instructions for Model Model Programming Choices 1F85 0471 1F83 0471 Non Programmable 1F83 0471 Thermostat Whitey __ Rodgers mV to 30 VAC NEC Class II 50 60 Hz or DC 20 to 30 VAC 1 5 A per terminal 2 5A maximum all terminals combined 45 to 90 F 7 to 32 C Heat 0 6 F Cool 1 2 F adjustable Heat 1 2 F Cool 1 2 F adjustable 32 to 105 F 0 to 41 C 90 non condensing max 4 to 150 F 20 to 65 C 3 4 H x 4 4 W x 1 3 D ATTENTION MERCURY NOTICE This product does not contain mercury However this product may replace a product that contains mercury Mercury and products containing mercury must not be discarded in household trash Do not touch any spilled mercury Wearing non absorbent gloves clean up any spilled mercury and place in a sealed container For proper disposal of a product containing mercury or a sealed container of spilled mercury place it in a suitable shipping container and send it to White Rodgers 2895 Harrison Street Batesville AR 72501 PART NO 37 6835B Replaces 37 6835A 0716 INSTALLATION A WARNING Thermostat installation and all components of the control system shall conform to Class II circuits per the NEC code
15. hange between Heat and Cool Manual Operation Bypassing the Program Programmable Thermostats Press or and then the HOLD button and adjust the temperature wherever you like This will override the pro gram The HOLD feature bypasses the program and allows you to adjust the temperature manually as needed What ever temperature you set in HOLD will be maintained 24 hours a day until you manually change the temperature or press Run Sched to cancel HOLD and resume the pro grammed schedule Program Override Temporary Override Press or Y buttons to adjust the temperature This will override the temperature setting until the next programmed time To cancel the temporary setting at any time and return to the program press Run Sched If the SYSTEM button is pressed to select AUTO the thermostat will change to Heat or Cool whichever ran last If it switches to heat but you want cool or it changes to cool but you want heat press both and buttons simultaneously to change to the other mode Enter the Heating Program 1 Press SYSTEM button to select Heat in the system switch area indicating the active mode being pro grammed 2 Press the Menu button and then press Schedule 3 The top of the display will show the day s being pro grammed The time and temperature flashing are also displayed 1 will also be displayed to indicate the period 4 Press or key to change the temperature to your selected temperature for th
16. ill occur within two days if batteries are not replaced Figure 2 Thermostat base and rear view of thermostat Mounting Hole Mounting Hole Place Level across Mounting Tabs for appearance only Place Level across Mounting Tabs for appearance only WIRING CONNECTIONS Refer to equipment manufacturers instructions for specific system wiring information After wiring see CONFIGURA TION section for proper thermostat configuration Refer to 37 6843 for 1F83 0471 1F85 0471 wiring diagram specifications TERMINAL DESIGNATION DESCRIPTIONS Terminal Designation Description Heat pump malfunction indicator for systems with malfunction connection Changeover valve for heat pump energized constantly in cooling Changeover valve for heat pump energized constantly in heating Compressor Relay 2nd Stage Compressor Heat Relay Emergency Heat Relay Stage 1 2nd Stage Heat 3rd Stage Heat in HP 2 Fan Relay Power for Heating Power for Cooling Common wire from secondary side of cooling system transformer or heat only system transformer 3 Wire Zone Valve Energized when no call for Heat THERMOSTAT QUICK REFERENCE Home Screen Description Figure 3 Home Screen Display Room Setting Temperature Temperature Displays the power level of l F i the 2
17. lacement Cooling system requires service or thermostat requires replacement Possible short in wiring Possible short in thermostat Possible short in heat cool fan system FAN Switch set to Fan ON Thermostat thermometer setting requires adjustment The location of the thermostat and or the size of the Heating System may be influencing the cycle rate Corrective Action Replace fuse or reset breaker Turn switch to ON Replace door panel in proper position to engage safety interlock or door switch Tighten connections Re light pilot Many furnaces have safety devices that shut down when a lock out condition occurs If the heat works intermittently contact the furnace manufacturer or local HVAC service person for assistance Diagnostic Set SYSTEM Switch to HEAT and raise the setpoint above room temperature Within a few seconds the thermostat should make a soft click sound This sound usually indicates the thermostat is operating properly If the thermostat does not click try the reset operation listed above If the thermostat does not click after being reset contact your heating and cooling service person or place of purchase for a replacement If the thermostat clicks contact the furnace manufacturer or a HVAC service person to verify the heating is operating correctly Same as diagnostic for No Heat condition except set the thermostat to COOL and lower the setpoint below the room temperature
18. of 0 Days for non programmable will eliminate the need for EMR and that step in the menu will be skipped 14 amp 15 Select Automatic Schedule 1F85 only with just one touch of the Auto Schedule key this feature allows you to program a desired comfort temperature into all the program periods along with a 6 set back for night periods of both Heat and Cool programs Factory default is On for both When Heat AS On and Cool AS On are activated while in Heat or Cool mode select desired setpoint tem perature and press Auto Schedule This value will be copied into all the morning day and evening program periods The night program periods will have a 6 F set back 16 amp 17 Select Fast Second Stage ON or OFF Heat pump or Multi stage only in the run mode with the fast Heat feature enabled FA Heat On if the Heat setpoint tem perature is manually raised by 3 F 2 C or more above the actual temperature using the second stage will energize immediately With FA OFF second stage will not energize until the setpoint temperature is 1 F or more above actual temperature for more than ten minutes The Fast Cool feature FA Cool provides the same controls when the setpoint temperature is lowered 18 Select Daylight Saving Time Calculation 1F85 only this feature will allow the thermostat to calculate the DST automatically and apply it to the Real Time Clock display Default On Use CA or touch keys to select the f
19. r OFF 1F85 only L 5 MENU CR Heat ME SL FA Adjustable Anticipation Selects heating cycle rate for MS or SS MENU CR Heat Pump SL FA Adjustable Anticipation Heat Pump only ME when heat pump selected in 1 Adjustable Anticipation Selects the cycle rate for cooling only when MS 2 or SS 1 is selected in item 1 or Selects the cycle rate for Emergency mode and Auxiliary stage if Heat Pump is selected in item 1 ENU CL OFF Compressor Lockout Time MENU Heat Cool Off Heat Auto Cool Off System Mode Configuration Heat Off with Fan icon with Automatic Changeover capability Heat Off without Fan icon Cool Off Auto Off ENU dL On dL OFF Selects Display Light On or OFF 0 1 HI 2 HI 3HI 4 HI Adjustable Ambient Temperature Display current temperature 1 LO 2 LO 3 LO 4 LO Selects Fahrenheit Celcius Temperature Display P3 PO P2 Defaults for 5 1 1 programming P3 but non programmable PO or 5 2 programming P2 is available on most models 1F85 onl Heat AS On or Automatic Schedule for heat mode 1F85 only ENU Cool AS On Automatic Schedule for cool mode 1F85 only ENU Heat FA On MENU CR Cool ME SL FA or CR Emer FA S lt ENU EN Q9 Fast Heat option may be disabled by selecting OFF NA to SS config ENU Cool FA On Fast Cool option may be disabled by selecting OFF NA to SS config MENU dS On m Selects Automatic daylight Savings Tim
20. teries 2 AA alkaline batteries are included with the thermostat To install the batteries pull the battery door as shown by the arrow and lift open Using the polarity indicated inside the battery door insert the batteries To close the battery door swing the door down while pulling in the direction of arrow Once fully down snap the door back into position To replace the batteries set system to OFF 2 3 Figure 1 Battery door shown open AA Alkaline Batteries aie ham hal Thermostat can be powered by system AC power or Battery If mD is displayed the thermostat is battery powered If itt is not displayed thermostat is system powered with optional battery back up When battery power remaining is approximately half the 1 gt will be displayed When Change gt is displayed install fresh AA alkaline batteries immediately For best results replace all batteries with new premium brand alkaline batteries such as Duracell or Energizer We recommend replacing batteries every 2 years If the home is going to be unoccupied for an extended 2 period over 3 months and gt is displayed the batteries should be replaced before leaving When less than two months of battery life remain the setpoint temperature will offset by 10 degrees 10 degrees cooler in Heat mode 10 degrees warmer in Cool mode If offset occurs the normal setpoint can be manually reset with or Cv Another offset w
21. ting and Cooling systems are off Cool Thermostat controls only the cooling system Auto Auto Changeover is used in areas where both heating and cooling may be required on the same day AUTO allows the thermostat to automatically select heating or cooling depending on the indoor temperature and the selected heat and cool temperatures When using AUTO be sure to set the Cooling temperatures more than 1 Fahrenheit higher than the heating temperature Emer Heat Pump models Thermostat controls only backup heating system PROGRAMMING For Programmable Model Only Set Current Time and Day 1 Press Menu and then Time button once The display will show the hour only 2 Press and hold either the or Cy key until you reach the correct hour and AM PM designation AM begins at midnight PM begins at noon 3 Press Time once again The display window will show the minutes only 4 Press and hold either the or key until you reach the correct minutes 5 Press Time once again The display will show the day of the week 6 Press the or Y key until you reach the current day of the week 7 Press Run to exit the Time mode IMPORTANT Manual Operation for Non Programmable Mode Press the SYSTEM button to select Heat or Cool and use the or buttons to adjust the temperature to your desired setting After selecting your desired settings you can also press the SYSTEM button to select AUTO to allow the thermostat to automatically c