Home

White Mountain VFP32FB2EL-1 Riding Toy User Manual

image

Contents

1. ER PREMIUM GJA PREMIUM G LOUVERED FLUSH boy ht 4 J Hayy Bi B LOUVERED FLUSH Ea Figure 7 Firebox Dimensions Page 6 23859 1 0308 FIREBOX INSTALLATION INSTRUCTIONS continued Locating Firebox Place firebox in framing opening Use the four 4 framing brackets provided on the firebox to attach firebox to framing Different hole locations can be used for finishing materials with thicknesses of 3 8 1 2 and 3 4 Attach these materials with screws provided two 2 per framing bracket See Figure 8 Framing brackets should fit directly against framing material Use at least one 1 nail per bracket to secure in place Check squareness ofthe firebox prior to securing to framed opening See Figure 9 ATTACH 4 FRAMING BRACKETS TO SIDES OF FIREBOX PRIOR INSTALLING UNIT TO FRAMED OPENING Figure 8 Ablack hood that is furnished with each firebox or optional hood MUST be installed before the firebox is used Failure to do so may create a possible fire hazard The hood is located behind upper louver or inside the firebox on flush face units If brass stainless steel or hammered pewter hoods are desired they can be purcha
2. Figure 30 Page 13 Blower Motor 110 VOLTAC The blower motor does not have oiling holes Do not attempt to JUNCTION BOX oil the blower motor FAN MOTOR ASSEMBLY Blower Wheels The blower wheels will collect lint and could require periodic cleaning If the air output decreases or the noise level increases it indicates a dirty blower wheel Remove fan and clean blower wheels Warning Unplugging of blower accessory will not stop the heater from cycling To turn off gas to the heater millivolt model push in gas control knob slightly and turn clockwise to OFF Do not force To turn off gas on direct ignition model turn gas line valve to OFF FAN SWITCH WHITE Figure 31 FBBS BLOWER ASSEMBLY COMPLETE 2 R8199 FAN CONTROL SWITCH Figure 32 Page 14 23859 1 0308 JUNCTION BOX WIRING INSTALLATION INSTRUCTIONS CAUTION ALL WIRING SHOULD BE DONE BY A QUALIFIED ELECTRICIAN AND SHALL BE IN COMPLIANCE WITH ALL LOCAL CITY AND STATE BUILDING CODES BEFORE MAKING THE ELECTRICAL CONNECTION MAKE SURE THAT MAIN POWER SUPPLY IS DISCONNECTED THE APPLIANCE WHEN INSTALLED MUST BE ELECTRICALLY GROUNDED IN ACCORDANCE WITH LOCAL CODES OR IN THE ABSENCE OF LOCAL CODES WITH THE NATIONAL ELECTRICAL CODE ANSI NFPA 70 LATEST EDITION A factory installed junction box is located on the lower right hand side of the fir
3. Figure 15 Figure 13 Figure 16 5 Working from the side cutout opening place the slightly opened air door assembly into the cutout opening as shown in Figure 17 TO INSTALL BVA 1 FRESH AIR KIT REMOVE RECTANGULAR CUT OUT WITH SHEET METAL CUTTERS Figure 14 2 Move the left hand curtain screen to the center of the firebox Figure 17 opening 3 Grasp the long control rod lever with control bracket items 7 6 While holding the door assembly in your left hand grasp the and 8 in Fresh Air Kit Parts List securely with a vise grips vise grip attached to the long control rod Rotate and move as shown in Figure 15 the control rod around until the inside end of the rod is mated 23859 1 0308 Page 9 with the hole in the front flange of the movable air door See Figure 18 Figure 18 DAMPER ASSEMBLY OUTER CASING FRESH AIR ROD TOP CUTAWAY VIEW OUTSIDE AIR ROD BRACKET Figure 19 7 Once the control rod is fed through the air door hole gently lift the outer air door plate assembly inward and upward until the mounting holes in the plate line up with the pilot holes in the side wrap 8 Install 4 screws to retain the Air Door assembly See Fig ure 20 Figure 20 9 Remove vise grip from control rod then check the operation of the Air Door The control lever should open the air door Page 10 when rotated upward and can be locked open by pulling for ward in
4. 70 LAT EST EDITION JUNCTION BOX CONNECTIONS 110 VOLT POWER SUPPLY JUNCTION BOX BLACK WHITE GROUND Figure 25 Page 12 A factory installed junction box is located on the lower right side of the firebox Wiring must be fed to the junction box and attached to the receptacle that is provided From right side of the firebox remove the screw securing the junction box assembly Leave approximately 6 of wire in the junction box for connection Attach black wire to one side of the receptacle and white wire to opposite side of receptacle The ground wire should be at tached to the green ground screw Install the receptacle into the junction box Attach cover plate Attention If installed do not damage gas inlet supply line when blower assembly is inserted into firebox In some cases removal the gas inlet supply line may be necessary Determine which type of firebox you have prior to installa tion See Figures 26 and 27 22 Premium Louvered Models REMOVE BOTTOM LOUVER TO INSTALL BLOWER ASSEMBLY Figure 26 REMOVE COVER PLATE TO INSTALL BLOWER ASSEMBLY Figure 27 23859 1 0308 Insert blower assembly into interior bottom of firebox Posi tion blower assembly so that you align the notch on back of blower assembly with the center screw on firebox back then push the blower assembly against firebox back The blow
5. The Breckenridge Premium Vent Free Universal Fireboxes ANSI 7 21 91 Ventless Fireplace Enclosures for Gas Fired Dec orative Type Unvented Room Heaters WARNING If the information in these instructions are not followed exactly a fire or explosion may result caus ing property damage personal injury or loss of life Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appli ance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from neigh bor s phone Follow the gas supplier s instruc tions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a quali fied installer service agency or the gas supplier DO NOT ATTEMPT TO MODIFY OR ALTER THE CONSTRUCTION OF THE FIREBOX OR ITS COMPO NENTS ANY MODIFICATION OR ALTERATION OF CONSTRUCTION MAY VOID THE WARRANTY OF THIS FIREBOX CHILDREN AND ADULTS SHOULD BE ALERTED TO THE HAZARDS OF HIGH SURFACE TEMPERATURE AND SHOULD STAY AWAY TO AVOID BURNS OR CLOTHING IGNITION YOUNG CHILDREN SHOULD BE CAREFULLY SUPER VISED WHEN THEY ARE IN THE SAME ROOM AS THE FIREBOX INSTALLATION INSTRUCTIONS AND OWNER S MANUAL UNIVERSAL FIREBOX FOR ALL VENT FREE LOG SETS MODELS VFP36FB2DL 2 VFP36FB2CL 1 VFP36FB2EL 1 VFP36FB2DF 2
6. means any individual firm corporation or company 54 which either in person or through a representative is engaged in Available from the American National Standards Institute Inc 11 West and is responsible for a the installation or replacement of gas 42nd St New York N Y 10036 23859 1 0308 Page 3 CLEARANCES Sidewall Clearances The clearance from the inside ofthe firebox to perpendicular combustible side wall should not be less than 6 See Figure 1 Firebox Side and Back Clearances The firebox outer casing side and back flanges are zero clearance to combustibles Top Framing and Finishing Combustible framing may rest on top of standoffs Combustible finishing materials may extend to the top standoff screws on the front edge of the outer wrap See Figure 2 COMBUSTIBLE MATERIALSALLOWED IN SHADED AREAS FIREBOX TOP VIEW i J FRONT FACE SIDE 4 S MAX PERPENDICULAR SIDE WALL Figure 1 CEILING T 12 FMAX 107 MANTEL 24 7 42 107 gr COMBUSTIBLES MIN E ALLOWED CEILING TO 22 TOP OF HOOD 84 MIN CEILING TO FLOOR 1 3 8 COMBUSTIBLE CLEARANCE REQUIRED FROM TOR EDGE HOOD Figure 3a Mantel Clearances with Standard Hood Page 4 Ceiling Clearances The ceiling height should not be less
7. this has not been done stop and consult your dealer for assistance with this planning Planning Your Installation Please note that the optional Fresh Air kit available for use with the Vent Free Firebox must be installed at the time ofthe initial installation Refer to pages 9 10 and 11 for detailed instructions for the air kit Accessory kits such as the 5 Blower kit Trim kits Mantles Full Cabinet Mantels plus other Decorative Frame Hood and Door accessory kits may be installed after the firebox is secured to the framed opening Refer to the instructions provided with each of the optional accessory kits for proper installation and operation Firebox Framing Firebox framing can be built before or after the firebox is set in place Framing should be positioned to accommodate wall covering and firebox facing material The firebox framing should be constructed of2 x 4 lumber or heavier The framing headers may rest on the top of the firebox standoffs Refer to Figures 6 and 7 for firebox framing dimensions LOUVERED FIREBOX MODELS gt COMBUSTIBLE MATERIALS ALLOWED Figure 5 ou 21 21 Figure 6 FIREBOX INSTALLATION INSTRUCTIONS continued
8. 2 Connection A The other fan control wire has a 1 4 male terminal Attach this terminal to the open terminal on the blower power cord See Figure 32 Connection B Route the wires away from moving parts of the blower as sembly and retain wires together near the blower motor using the plastic purse clip provided To complete the installation plug the power cord into the junction box receptacle at the right rear corner of the firebox outer wrap See Figure 30 If room permits the power cord can be located from the out side of the unit looking through the junction box access hole with the junction box removed then plug up the power cord before reinstalling the pre wired junction box Once all connections are made electrically it is recommend ed that you test the blower fan control operation by turning on power to the blower Caution 110 Volt Then apply heat to the fan control switch inside the firebox with a lighter or match until blower is activated Once blower is activated check for proper operation Do not place hands near blower assembly or other wiring while power is on Replace blower access plate and or reinstall the brick liner panels if provided This completes the installation of the optional FBB5 Blower kit accessory Note This blower is equipped with a heat activated fan control switch Blower will operate when the firebox warms up and will turn off automatically when the firebox cools down
9. Do not cut or remove the grounding prong from this plug For an ungrounded receptacle an adapter which has two prongs and a wire for grounding can be purchased plugged into the ungrounded receptacle and its wire connected to the receptacle mounting screw With this wire com pleting the ground the appliance cord plug can be plugged into the adapter and be electrically grounded Caution Label all wires prior to disconnection when servic ing controls Wiring errors can cause improper and dangerous operation Verify proper operation after servicing Note Junction box on right side of firebox must be pre wired at time of firebox installation for use with blower assembly A standard wall ON OFF wall switch or optional SCV1 Vari able Speed Control Kit should be installed to activate pow er to the Firebox and control the operation of the 5 Blower assembly It is recommended that installation ofthe wiring be performed by a qualified electrician See Figure 25 1 Ifinstalled turn OFF gas supply to firebox gas log 2 Ifapplicable turn OFF electric supply to firebox CAUTION ALL WIRING SHOULD BE DONE BY A QUALIFIED ELECTRICIAN AND SHALL BE IN COMPLIANCE WITH ALL LOCAL CITY AND STATE BUILDING CODES BEFORE MAKING THE ELECTRI CAL CONNECTION MAKE SURE THAT MAIN POWER SUPPLY IS DISCONNECTED THE APPLIANCE WHEN INSTALLED MUST BE ELECTRICALLY GROUNDED IN ACCORDANCE WITH LOCAL CODES WITH THE NATIONAL ELECTRICAL CODE
10. H LEDGE CENTER PART NUMBER INDEX DESCRIPTION NO VFP36FB2DL VFP36FB2EL VFP36FB2CL VFP36FB2DF VFP36FB2EF VFP36FB2CF BRACKET BOTTOM BRICK gt 19401 19401 19401 19401 RETAINER BRICK PANEL RIGHT R8669 9420 8228 19990 19990 19990 19401 19401 R8666 R9419 3 4 5 20020 R7051 R8212 R8727 19990 20020 R7051 R8212 R8727 19990 R9292 1 7 10 11 12 1 1 1 16 19401 19401 R8669 R9420 20145 R7052 R8201 20145 R7052 R8201 R8727 HEARTH LEDGE CENTER RETAINER HEARTH Page 16 23859 1 0308 PARTS LIST INDEX PART NUMBER DESCRIPTION VFP42FB2DL VFP42FB2EL VFP42FB2CL VFP42FB2DF VFP42FB2EF VFP42FB2CF 17247 17247 17187 17187 10554 10554 17188 17188 17162 17162 R3492 R3492 R3491 R3491 19945 20448 BEE 2 za a 5 6 BE 19401 19401 10 _2 e a 16 za 17247 N 10554 N 17162 R3492 R3491 19945 17247 A 10554 A 17162 R3492 R3491 19945 19401 BRACKET BOTTOM BRICK RETAINER gt 2 gt 2 19401 19401 R8672 R9421 R8672 R9421 R8285 19984 19984 R7053 R7053 RS201 R8201 R8727 R8727 19990 19990 19984 R7053 R8201 R8727 19990 R9292 R9293 R9296 23004 19984 R7053 R8201 R8727 19990 R9292 R9293 R9296 23004 oo NO 1 2 3 4 5 1 10 12 13 14 15 16 17 19 20 21 HOW ORDER REPAIR PARTS Parts be ordered through your service person or dealer For
11. VFP36FB2CF 1 VFP36FB2EF 1 VFP32FB2DL 2 VFP32FB2CL 1 VFP32FB2EL 1 VFP32FB2DF 2 VFP32FB2CF 1 VFP32FB2EF 1 VFP42FB2DL 2 VFP42FB2CL 1 VFP42FB2EL 1 VFP42FB2DF 2 VFP42FB2CF 1 VFP42FB2EF 1 UL LISTED NATIONAL FIREPLACE INSTITUTE NFI We suggest that our gas hearth products be installed and serviced by profes sionals who are certified in the U S by the National Fireplace Institute NFI as CERTIFIED NFI Gas Specialists www nficertified org FOR USE ONLY WITH A LISTED GAS FIRED UN VENTED DECORATIVE ROOM HEATER NOT TO EXCEED 40 000 BTU H DO NOT BUILD A WOOD FIRE WARNING Improper installation adjustment alteration service or maintenance can cause injury or property dam age Refer to this manual For assistance or additional in formation consult a qualified installer service agency or the gas supplier Carefully review the instructions supplied with the decora tive type unvented room heater for the minimum fireplace size requirement DO NOT INSTALL A VENT FREE LOG SET IN THIS FIREBOX UNLESS THIS FIREBOX MEETS THE MINIMUM DIMENSIONS REQUIRED FOR THE INSTALLATION Page 1 TABLE OF CONTENTS SECTION PAGE Important Safety Information 3 er 3 amp Firebox Installation nie ons ee 5 7 Insjallne 7 8 Gas Line Connection een 8 Optional Fre
12. best results the service person or dealer should order parts through the distributor Parts can be shipped directly to the service person dealer parts listed in the Parts List have a Part Number When ordering parts first obtain the Model Number from the name plate on your equipment Then determine the Part Number not the Index Number and the Description of each part from the following appropriate illustration and list Be sure to give all this information Firebox Model Number Part Description Firebox Serial Number Part Number Do not order bolts screws washers or nuts They are standard hardware items and can be purchased at any local hardware store Shipments contingent upon strikes fires and all causes beyond our control 23859 1 0308 Page 17 PARTS VIEW 23859 1 0308 Page 18 ACCESSORIES Fan Kit u Designed to provide forced air flow 5 Wall mounted variable speed control for use with 5 blower Deluxe and Premium Fireboxes 1 Standard 3 Piece Frame Kits Black Brass Stainless Steel or Hammered Pewter Frame Kits Contact dealer for all available optional frame kits Extruded Aluminum Frame Ki
13. ctor installer supplied you will need from the firebox fireplace to the exterior surface of the outside wall where the air kit hood will be installed Add a few extra inches to the length to allow for easier attachment of the outside duct connection prior to securing the outside rain cap hood to the building 2 Secure the 4 dia duct to the Air Door assembly collar on the firebox fireplace with band clamps or screws 3 Run the other end of the duct through the exterior wall cut out 4 From the outside of the building connect the duct to the collar on the outside air vent assembly with band clamp or screws to secure 5 Mate the outside rain cap hood over the air vent seal with caulk as necessary then secure with screws provided to the exterior wall surface See Figure 22 and 23 6 Figure 24 illustrates the various options for installation of the air duct run possibilities Page 11 OPTIONAL SINGLE SPEED BLOWER INSTALLATION INSTRUCTIONS Attention Install blower assembly before connecting gas inlet supply line Wiring The appliance when installed must be electrically grounded in accordance with local codes or in the absence of local codes with the National Electrical Code ANSI NFPA 70 if an exter nal electrical source is utilized This appliance is equipped with a three prong grounding plug for your protection against shock hazard and should be plugged directly into a properly grounded three prong receptacle
14. ebox Wiring must be fed to the junction JUNCTION BOX CONNECTIONS box and attached to the receptacle that is provided Remove the knockout in the installed junction box to accept wiring into the junction box Install a UL listed cable clamp not supplied in the knockout hole Leave approximately 6 of wire in the junction box for connection 110 VOLT POWER SUPPLY JUNCTION BOX BLACK Attach black wire to one side ofthe receptacle and white wire to opposite side of receptacle The ground wire should be attached to the green neutral screw WHITE GROUND Install the receptacle into the junction box Attach cover plate Figure 33 MAINTENANCE Keep the control compartment logs and burner area surrounding the Never obstruct the flow of the combustion and ventilation air Keep logs clean by vacuuming or brushing area at least twice a year the front of the firebox clear of all obstacles and materials THE LOGS CAN GET VERY HOT HANDLE ONLY WHEN Screens must be closed during operation COOL Always turn off gas to the pilot before cleaning For relighting refer to lighting instructions located on the log set 23859 1 0308 Page 15 PARTS LIST INDEX PART NUMBER DESCRIPTION NO VFP32FB2DL VFP32FB2EL VFP32FB2CL VFP32FB2DF VFP32FB2EF VFP32FB2CF BRACKET BOTTOM BRICK 19401 19401 19401 19401 RETAINER BRICK PANEL RIGHT R8666 R9419 R8226 19990 BLOWER COVER PLATE R9293 R9293 R9293 R9293 HEART
15. eel VB4H36SS Stainless Steel VB4H42SS Stainless Steel VB4H42HP VB4H32HP VB4H36HP Finishing All joints top bottom and sides where the wall or decorative facing material meets the firebox surround should be sealed with a non combustible material Hearth extensions are recommended but not required for these fireboxes GAS LINE CONNECTION The firebox is designed to accept a 3 8 inch gas line for an approved vent free gas logset Have the line installed by a qualified service person in accordance with all building codes Consult local building codes to properly size the gas supply line leading to the 3 8 inch hook up at the unit The state of Massachusetts requires that a flexible appliance connector cannot exceed three feet in length Gas access holes are provided on both sides of the firebox See Figure 11 models with ceramic brick panels installed carefully remove the indented knockout in the ceramic brick panel using a drill or utility knife See Figure 12 When installing optional ceramic fiber side panels into firebox GAS ACCESS HOLES lay panel on a flat surface Remove the gas line knockout round depression in the appropriate side panel using a drill or utility knife Check gas type Use only the gas type indicated on the gas log set rating plate If the gas listed on the plate is not your type of gas supply DO NOT INSTALL Contact your dealer for proper model Always use an external regulator f
16. eneral question about our products please e mail us at info empirecomfort com COMFORT SYSTEMS If you have a service or repair question please contact your dealer www empirecomfort com Page 20 23859 1 0308
17. er wheel must be centered with the back wall of the firebox The magnets on the back and bottom of blower assembly will suf ficiently hold blower assembly in place Note For field installation of blower assembly it may be easier to 7 remove rear cover panel to install blower This eliminates the need to remove brick liner panels but the blower would have to be installed prior to installing the firebox into a wall or chase See Figure 28 REAR COVER PANEL MAY BE _ REMOVED TO INSTALL BLOWER REINSTALL COVER AFTER BLOWER IS INSTALLED Figure 28 Once the blower assembly is in position locate the plug but ton in the top right rear corner of the firebox Remove the plug with a standard screwdriver and discard plug Next find the fan control switch and wire assembly Feed the wires through the hole at the top of the firebox and secure the fan control switch with 2 6 screws provided See Figure 29 FAN CONTROL SWITCH LOCATION Figure 29 The fan control wires will slide down between the firebox and outer wrap near the blower assembly See Figure 29 23859 1 0308 10 11 12 13 14 15 One fan control wire will have a 1 4 female terminal that must be attached to the open terminal on the blower motor See Figure 3
18. ll installation precautions required and has complied with all the requirements 2 Installer must have owner fill out and mail warranty card of the authority having jurisdiction supplied with firebox State of Massachusetts The installation must be made by a licensed plumber or gas fitter in the Commonwealth of Massachusetts The state of Massachusetts requires that a 3 Installer should show owner how to start and operate log set that is installed into firebox Important flexible appliance connector cannot exceed three feet in All correspondence should refer to complete Model Number length Serial Number Sellers of unvented propane or natural gas fired supplemental Notice During initial firing of this firebox with a log set installed its room heaters shall provide to each purchaser a copy of 527 paint will bake out and smoke will occur To prevent triggering of CMR 30 upon sale of the unit smoke alarms ventilate the room in which the unit is installed In the State of Massachusetts unvented propane and natural Qualified Installing Agency gas fired space heaters shall be prohibited in bedrooms and Installation and replacement of gas piping gas utilization bathrooms equipment or accessories and repair and servicing of equipment installation must conform with local codes or the absence shall be performed only by a qualified agency The term qualified of codes with the National Fuel Gas Code ANSI Z223 1 agency
19. or all LP fireboxes to reduce the Figure 11 supply tank pressure to a maximum of 14 w c This is in addition to the regulator fitted to the log set WARNING CONNECTION DIRECTLY TO AN UNREGULATED L P TANK CAN CAUSE EXPLOSION Install only aANSI Z21 11 2 vent free log set into this firebox Figure 12 Page 8 23859 1 0308 OPTIONAL FRESH AIR KIT INSTALLATION INSTRUCTIONS FOR DELUXE AND PREMIUM FIREBOXES The optional Fresh Air Kit is designed to introduce outside air to the fireplace or firebox as desired It must be installed prior to or at the time of fireplace or firebox installation to framing The Fresh Air kit must be installed prior to the installation of wall board or other finishing materials around the unit Tools needed Gloves Metal snips Vise Grip Nut Driver Standard Screwdriver Caution Sharp edges Air Door Installation for Vent Free Firebox Models VFP 32 36 42 FB 1 Begin by removing the rectangular cutout located on the left side of the firebox Use gloves and sheet metal snips to cre ate the opening for the Air Door assembly to install into See 4 Next with the vise grip attached feed the long control rod Figures 13 and 14 through the small rectangular opening at the left side of the firebox face Carefully position the rod and bracket so that the bracket can be secured to the inside opening of the firebox with two screws See Figure 16 Do not remove vise grips at this time
20. ppliance be kept clean Provide adequate clearance around air openings into This Empire Comfort Systems Inc firebox and its Installation other than as instructed by Empire components have been tested and will operate safely when Comfort Systems Inc installed in accordance with this installation manual Installation and or use of any component part or Read all instructions before starting installation then accessory not approved by Empire Comfort Systems follow these instructions carefully during installation Inc in combination or assembly with a Empire to maximize firebox benefit and safety Report to your Comfort Systems Inc firebox not withstanding any dealer any parts damaged in shipment independent testing laboratory or other third party approval of such component part or accessory Any such action may create a possible fire hazard Consult your local building codes The Empire Comfort Systems Inc warranty will be voided by and Empire Comfort Systems Inc disclaims any responsibility for the following actions Installation of any damaged firebox Firebox Screen Modification of the firebox or any of the components The firebox screen must be in place when the firebox is parts thereof operating INTRODUCTION Instructions to Installer piping or b the connection installation repair or servicing of 1 Installer must leave instruction manual with owner after equipment who is experienced in such work familiar with a
21. sary to determine where the unit is to be installed and whether optional accessories are desired Gas supply piping should also be planned at this time A gas shut off must be in this line The firebox can be mounted on any of these surfaces 1 A flat hard combustible or non combustible surface 2 A raised platform of combustible or non combustible material 3 Recessed into the floor as illustrated by Figure 4 flush face and Figure 5 louvered models 4 Supported under all 4 corners of the firebox so that contact is made on all four perimeter edges on the bottom of the unit Example Four 4 concrete masonry blocks If the firebox is installed directly on carpeting tile or other combustible material other than wood flooring it should be installed on a metal or wood panel extending the full width and depth of the unit FLUSH FACE MODELS NON COMBUSTIBLE N FINISHING MATERIAL TO FIREBOX OPENING 4 COMBUSTIBLE MATERIALS ALLOWED 4 Figure 4 Premium Vent Free Firebox Framing Dimensions in inches Model VFP32FB VFP36FB VFP42FB Attention Add 3 3 4 to A Dimension when using flush mantel base Framing dimension A includes a three inch clearance for standoffs on firebox 23859 1 0308 Framing Depth Atthis point you should have decided what components to include in your installation and where the firebox is to be located If
22. sed as an option Attachment is the same as the standard black hood Flush Face Models 1 On flush face models loosen the two screws A holding firebox top to face panel then slide the hood flange between the firebox top and face panel and re tighten the screws 2 Install one 1 screw at each end of the hood as shown C Louvered Models 1 If you have a louvered model remove upper louver 2 Place the top hood flange on top of the firebox then install three screws through the firebox top from below and screw into the pilot holes in the hood flange B 3 Install one 1 screw at each end of the hood as shown C 4 Re install louver Caution The hood must be installed prior to operation of appliance See Figure 10 23859 1 0308 ox FIREBOX OPENING x CHECK TO SEE THAT BOX IS SQUARE PRIOR TO ATTACHING TO FRAMING EN Figure 9 INSTALLING HOOD Flush Face Models Louvered Models Page 7 INSTALLING HOOD continued Extended Hoods If your non combustible facing material is over 1 in thickness that will be used to finish this firebox an extended hood is available that will extend out 2 farther out into the room Contact your local dealer for details VB4H32BL Standard Black VB4H36BL Standard Black VB4H42BL Standard Black VB4H32BR Polished Brass VB4H36BR Polished Brass VB4H42BR Polished Brass VB4H32SS Stainless St
23. sh Air Kit Installation 9 11 Optional Single Speed Blower Installations 8 12 14 Junction Box Wiring Installation nahe 15 MAIER ee een 15 EA 16 17 How to Order Repair Par ans en 17 PN Wear 18 A CCESSOTICS aico 19 20 Page 2 23859 1 0308 IMPORTANT SAFETY INFORMATION The installation must conform with local codes or in safety screen or guard removed for servicing an the absence of local codes with the National Fuel Gas appliance must replaced prior to operating the ap Code ANSI Z223 1 latest edition and to the National pliance Provide adequate combustion and ventilation electrical Code ANSI NFPA70 latest edition air NOTE Installation and repair should be done by a quali The flow of combustion and ventilation air MUST NOT fied service person The appliance should be inspected obstructed before use and at least annually by a qualified service person More frequent cleaning may be required dueto combustion chamber and adequate accessibility excessive lint from carpeting bedding material etc It clearance for servicing and proper operation NEVER is imperative that control compartment burners and obstruct the front opening of the appliance circulating air passageways of the a
24. than 42 from the top ofthe hood See Figures 3a and 3b Mantel Clearances Vent free firebox models must use the hood supplied with the firebox or one of the optional hood kits available for each model If a combustible mantel is installed it must meet the clearance requirements detailed below Grate Clearance The minimum clearance between the front legs ofthe grate and front edge of the firebox is 2 Leave at least 36 clearance from the front of the firebox COMBUSTIBLE 2 FINISHED WALL BADER ta OR MANTEL FINISH WITH TRIM KIT OR NON COMBUSTIBLE MATERIAL f f STAND OFF AS DESIRED N FIREBOX Figure 2 CEILING 12 10 IL MANTEL 40249 42 N gr COMBUSTIBLES MIN ALLOWED CEILING TO TOP OF HOOD 16 84 MIN 3 8 COMBUSTIBLE CEILING TO FLOOR CLEARANCE REQUIRED FROM TOP EDGE OF FIREBOX 1 oo MIN a4 EXTENDED SERIES FIREBOX FACE Figure 3b Mantel Clearances with Optional Extended Hood 23859 1 0308 FIREBOX INSTALLATION INSTRUCTIONS Any vent free Gas Log Heater must be For use with approved ANSI Z21 11 2 unvented room heater Follow and complete the installation instructions of the gas log set and the requirements of this firebox Check all fittings for leaks before lighting the gas log set In planning the installation for the firebox it is neces
25. to the notch at the top of the control lever bracket 10 To close simply disengage by letting the lever rotate down ward The air door will remain closed by magnetic action See Figure 21 OUTSIDE AIR ROD BRACKET FRESH AIR ROD CONTROL LEVER ssl LEFT SIDE VIEW OF FIREBOX OPENING Figure 21 FRESH AIR KIT PARTS LIST INDEX PART QUANTITY NO NO DESCRIPTION SUPPLIED 10124 OUTSIDE AIR HOOD 18476 OUTSIDE AIR TUBE ASSEMBLY 1 R8196 WASHER SILICONE BV 4 iosas DaMPERASSEMBLY J s kon ruporarcurey 1 To Trs so rop rrestamavn BRACKET OUTSIDE AIR 23859 1 0308 OUTSIDE PLATE VENT SCREEN ASSEMBLY AIR DOOR 2 ASSEMBLY HOOD 4 DIA AIR DUCT CONNECTOR INSTALLER SUPPLIED FIREBOX OR FIREPLACE Figure 22 CAULKING RAIN CAP DUCT TERMINATION WALL Caulk and Install Duct Termination Figure 23 nn DUCT E TERMINATION CNOT PROVIDED CEILING m EXTERIOR Li WALL N 40 MAX DUCT 5 DUCT RUN N J 1 DUCT RAIN CAP _ _______ 8 DUCT FAIS OIJ 12 MIN 1 GROUND LEVEL Figure 24 23859 1 0308 Completion of Air Kit installation 1 Determine the length of 4 Dia rigid or flex duct conne
26. ts Black Brass Stainless Steel or Hammered Pewter Standard Hood Brass hood BR Contact dealer for all available planes eel optional hood accessories Hammered Pewter HP 23859 1 0308 Page 19 ACCESSORIES continued Extended 4 Hoods Extended hoods that extend out 2 farther than the standard h t te thicker surround materials oods to accommodate thicker surrou id Contact dealer for all available Available as optional kits in Black Brass Hammered Pew gcppasoriss ter and Stainless Steel finishes Louvers Styles include Slat Mission Arch and Leaf Patterns Contact dealer for all available Available as optional kits in Black Brass Hammered Pew optional louver accessories ter and Stainless Steel finishes Bottom Trim Strip Available as optional kits in Black Brass Hammered Pew Contact dealer for all available ter and Stainless Steel finishes optional trim accessories 5 Available as optional kits in Black Brass Hammered Pew Contact dealer for all available Decorative Door Kits 5 ter and Stainless Steel finishes optional frame kit accessories Contact dealer for all available optional decorative door kit accessories Available as optional kits in Black Brass Hammered Pew Decorative Brame Kits ter and Stainless Steel finishes Rs Empire Comfort Systems Inc 918 Freeburg Ave Belleville IL 62220 If you have a g

Download Pdf Manuals

image

Related Search

Related Contents

Tucano Riva  128L / 128B / 130H / 135L / 135B / 145L / 145B Decespugliatore  Gigabyte M1405 Laptop User Manual  Lenmar Enterprises BCV636 User's Manual  Mini-Bomba-Telescópica Mini-pompa-telescopica Mini  User`s Manual - Gene-Foci  Canon VB-H41 Installation Guide  Operating instructions MOVITRAC 07 3 x 400 V - SEW    Behringer TRUTHB2030A User's Manual  

Copyright © All rights reserved.
Failed to retrieve file