Home
Whirlpool 30 eye-level range Double Oven User Manual
Contents
1. PE ihi Installation Instruction fat 2g RASA A a Uu sp tS P BR E pong SS PORQ EN A 30 EYE LEVEL MICROWAVE RANGE 30 EYE LEVEL RANGE 1 Before you begin Read these instructions completely and carefully If followed they will simplify the installation job If your range does not have a microwave upper oven disregard the following microwave infor mation IMPORTANT Observe all governing codes and ordinances Failure to follow these instructions could lead to fire or electrical shock hazard WARNING The microwave oven in this unit is designed for household use only It must not be used for commercial purposes A Space WALL RECEPTACLE CAUTION Reaching over heated surface elements causes risk of being burned To eliminate hazard cabinets should NOT be installed above range If cabinets are already provided reduce hazard by instal ling a range hood Hood should project horizontally beyond bottom of cabinets by a minimum of 5 inches PRECAUTIONS TO AVOID POSSIBLE EXPOSURE TO EXCESSIVE MICROWAVE ENERGY Do not attempt to operate this oven with the door open since open door operation can result in harmful exposure to microwave enerqy It is important not to defeat or tamper with the safety interlocks Do not place any object between the oven front face and the door or allow soil or cleaner residue to accumulate on sealing surfaces Do not op
2. hot but NOT glow red BROIL Set selector switch on BROIL Turn thermostat to high The top element should glow red and indicator light should be on C Rotisserie if optional rotisserie kit is installed Place straight oven rack on bottom ledge position Place broiler pan on oven rack Place special rotisserie rack on broiler pan Position the spit bar on this special rack Rotation should start when spit bar is inserted into recep tacle in back of oven D Clock if so equipped Refer to operating instructions in the Use and Care Guide packed in the oven E Cleaning See the Use and Care Guide packed in the oven for proper care and cleaning instructions Before you call for service See the Use and Care Guide for trouble shooting checklist Be sure pigtail power cord is plugged in Check for blown fuses or tripped circuit breaker If you must call for service You will need the appliance model and serial number Find the serial plate on the front frame of the main oven behind the main door For the Eye level Microwave it is on the front frame behind the microwave oven door Installing optional vent hood CAUTION Disconnect from electrical supply before installing vent hood A Space required 71 718 TOTAL HEIGHT WITH VENT HOOD 66 1 8 OVERALL HEIGHT OF EYE LEVEL RANGE Install vent hood BEFORE making final electrical con nection When measuring remember that l
3. ARIS Laine Terminal block cover is located on back of the ap pliance near the bottom Remove retaining screws to expose electrical terminal block USE ONLY the supplied 34 brass nuts when connec ting cord USE ONLY ring type terminals to connect cord BORDA SALIDA oi Tos BE paver oma on BAER Di dE RI A S 4 e B Strain relief reguired LOCKING CLAMPING INSERT FROM SCREWS UNDER FRAME e A AR AAA SI LA ON A A Disconnect clamping ring from strain relief Push relief from bottom through hole beneath terminal block Tighten clamping ring from above onto strain relief threads A RT inme ana m c A a n TT a E RUN CORD THROUGH STRAIN RELIEF Ee A GA a gt s Run cord or cable through strain relief Leave enough slack to attach ring type terminals to terminal block Tighten clamping screws C If frame grounding is allowed A MO LN O LR INDI IT TAE NA SILVER COLORED TERMINAL NEUTRAL WHITE OR CENTER TA ANNE AS E Wu mev EE ttn Te eR N a pi Use this wiring method ONLY if local codes permit connecting frame grounding conductor to neutral wire of power cord THIS APPLIANCE IS MANUFACTURED WITH NAME TERMINAL CONNECTED TO THE If local codes do not permit grounding through the neutral The 3 conductor cord or cable assembly must be replaced by a 4 conductor cord The replacement cord must be rated 240 volts 50 amperes and investigated f
4. ack of a free standing range may be installed against a vertical wall Sides may be installed against base cabinets or against vertical walls extending above upper edge of the cook top B Check microwave for damage Remove all packing material from the oven cavity When unpacking the unit check for damage such as misaligned door damaged gaskets around the door or dents inside the oven or on the exterior If there is any damage please do not operate the unit until it has been checked by an author ized Whirlpool trained service technician C Electrical requirements IMPORTANT SAVE THESE INSTRUCTIONS FOR THE LOCAL ELECTRICAL INSPECTOR S USE WARNING DO NOT PLUG THE PIGTAIL POWER CORD INTO A LIVE WALL RECEPTACLE BEFORE CORD IS PERMANENTLY CONNECTED TO THE TERMINAL BLOCK 1 This appliance must be connected to the proper electrical voltage and frequency as specified on nameplate Models rated at 15 KW on 240 volts 11 25 KW on 208 V or more require a separate 50 ampere circuit Models rated less than 15 KW on 240 volts 11 25 KW on 208 V require a separate 40 ampere circuit Fuse both sides of the line DO NOT fuse the neutral A time delay fuse or circuit breaker is recommended Wire sizes must conform to the requirements of the National Electrical Code and or local codes and ordinances for the kilowatt rating of the range The nameplate is located on the front frame of the main oven behind the main door For t
5. e connectors must conform to the ampere rating of the range as stated in paragraph C 1 If local codes permit your range may be connected with a three wire flexible type UL listed pigtail power cord of the proper ampere rating Plug must match a 3 wire NEMA type 10 50R receptacle shown below 3 WIRE 4 WIRE ws RECEPTACLE RECEPTACLE v _ x 10 50R 14 50R w CAUTION FOR MOBILE HOME USE A 4 WIRE POWER CORD MUST BE USED This appliance is manufactured with ground connected to frame This must be revised so green ground wire of 4 wire power cord is connected to frame If using a 4 wire NEMA type 14 50R receptacle shown above you must use a matching 4 wire UL listed pigtail power cord Cord should be type SRD or SRDT at least 4 feet long with all conductors ending in ring terminals at the appliance MINIMUM CONDUCTOR SIZE 4 WIRE COPPER POWER CORD For 40 ampere circuits two No 8 conductors one No 10 white neutral and one No 8 green ground For 50 ampere circuits two No 6 conductors one No 8 neutral and one No 6 green ground CAUTION Power Cord Requirements Only a power supply cord kit rated at 240 volts 50 amperes and investigated for use with ranges shall be used AAA T h _f aP o e o eee AN Begin the installation Remove racks and all other contents from oven before moving appliance Be sure to remove all packaging material cardboard protective film etc f
6. erate the oven if it is damaged It is particularly important that the oven door close properly and that there is no damage to the 1 Door bent 2 Hinges and latches broken or loosened 3 Door seals and sealing surfaces The oven should not be adjusted or repaired by anyone except properly qualified service personnel The oven should be checked for microwave leakage by qualified service personnel after a repair is made Do not operate the oven if the door glass is broken Height for range with eye level oven plus vent hood 71 7 8 min Height for range with eye level oven alone 66 1 8 min Width between counters 30 3 8 to 30 1 2 Height of countertop 35 5 8 to 36 13 16 Depth 22 1 2 Pigtail receptacle location 7 max from floor 8 to 22 from either cabinet To prevent discoloration of base cabinet front of oven frame must extend at least 1 2 beyond front surface of cabinets Do not seal range to cabinets The copper power cord pigtail must run downward left or right to the wall receptacle to avoid pinching the cord between rear portion of the range and wall Top of eye level oven may be installed against bottom of over head cabinet However for easy installation and removal allow 1 clearance between oven top and cabinet or 1 clearance between hood top and cabinet When hood is attached to cab inet allow 1 clearance between hood bottom and oven top The b
7. eveling legs will be ad justed Total height needed for vent hood is 71 7 8 with legs extended about half way The top of the vent hood may be installed against bottom of over head cabinets B Remove knockout plug REMOVE KNOCKOUT PLUG POWER SUPPLY RECEPTACLE Position appliance so that front and back are accessible Knockout plug is at right rear of oven top panel Use hammer and screwdriver as shown to remove knock out plug CAUTION Avoid damage to power supply receptacle located below knockout plug VENT HOOD P BOTTOM gt HIT POWER SUPPLY RECEPTACLE Reach through hole in bottom of vent hood pull out power cord until all slack is removed Place vent hood on the top of the oven Lift front of vent hood and connect vent hood power cord to the receptacle in the top of the oven Rest vent hood on the top of the oven VENT HOOD ORIGINAL BACK POSITION MOUNTING PLATES TURN TO THIS POSITION OVEN BACK Loosen screws holding the 2 mounting plates on the back of the vent hood Rotate these plates as shown until the lower holes line up with matching screwholes in the back of the oven Fasten plates to the oven back using the 2 screws supplied with the vent kit Retighten the screws that were loosened in the vent hood To connect ducting or to use vent hood in a ductless in stallation see instructions packed with the vent hood See instructions packed with the vent hood for deta
8. he Eye level Microwave it is on the front frame behind microwave oven door All wires ending at the appliance must terminate in ring type terminals All power cords and cables to appliance must be fitted with a UL approved strain relief The range should be connected with copper wire only Aluminum wire requires special connectors Improper use may create a fire hazard Appliance may be connected directly to the fused disconnect or circuit breaker box through flexible armored or non metallic sheathed copper cable Do not use an extension cord Allow 4 feet min slack so appliance can be moved for servicing Wire sizes must conform to the ampere rating of the range See paragraph C 1 above WARNING THE TERMINAL BLOCK ON THE APPLIANCE ACCEPTS COPPER WIRE ONLY NOT ALUMINUM IF ALUMINUM HOUSE WIRING MUST BE CONNECTED USE ONE OF THE FOLLOWING PROCEDURES e Connect copper wire to the range terminal block using ring terminals e Connect the copper wire to the aluminum house wiring using special connectors UL listed and designed for joining copper to aluminum e Wire size and connectors must conform to the ampere rating of the range as stated in paragraph C 1 e Attach special ring connectors to the aluminum house wiring that are UL listed and designed for joining copper to aluminum These special ring connectors available at electrical supply houses can be attached directly to the range terminal block e Th
9. ils on proper use and care When vent hood installation is finished go to Step 4 Level and position range on page 6 RGA E THe aa RS S sree PE pO URL a aR ORR ARE RRM 138 no Mie BE IS A ATENA Whirlp 100 HOME poo Making your world a little easier In the event your WHIRLPOOL appliance should need service call the dealer from whom you purchased the appliance or a WHIRLPOOL franchised TECH CARE service company He is in the Yellow Pages of your telephone directory listed under Appliances Household Major Service and Repair You can also obtain his name and number by dialing free the Whirlpool COOL LINE service 800 253 1301 Dial just as on Normally dial long distance A special operator will tell you the name and number of your nearest Whirlpool TECH CARE service outlet During normal working hours Whirlpool consultants at this same number will also answer any questions about operating or maintaining your appliance not covered in your Use and Care Guide gt es Whirlpool TECH CARE FRANCHISED SERVICE Learn the benefits of using TECH CARE service for maintaining the quality originally built into your WHIRLPOOL appliance Part No 313480 Rev B Printed in U S A
10. or use with ranges 1 Connect neutral wire to the center silver colored terminal 2 Connect remaining 2 wires to the terminals on either side of the silver colored terminal 3 Use ring type terminals only Connect with the brass nuts that are taped to the frame Do not loosen fac tory installed nuts already on the terminal 4 Replace terminal block cover D 4 wire electrical connections SILVER COLORED TERMINAL GREEN g WHITE OR CENTER LINE 1 STRAIN RELIEF Use this wiring method for mobile homes and whenever a 4 wire installation is reguired 1 Remove the grounding strap screw from the range frame Keep this ground screw Bend up the ground ing strap so that it does not contact the range frame 2 Connect the green ground wire to the frame of the appliance with the ground screw using the hole in the frame where the ground strap was removed 3 Connect the white neutral wire of the power cord to the silver colored terminal of the terminal block Con nect the remaining wires to the outer terminals 4 Replace the terminal block cover Level and position the range NOTE If installing the option vent hood go to that step now Instructions are on page 7 Level and position the range after the vent hood is attached LEVEL SPIRIT T1 A 3 8 ALLEN WRENCH LEVELING DRAWER REMOVED A Leveling Move range into final operating position Use caution when moving this ap
11. pliance to prevent damage to floor coverings The weight of the appliance may cause rip ping scratching or other damage to the floor For best results slide appliance onto cardboard or hardboard before moving to prevent damage Place rack in oven Put spirit level on rack If range needs leveling remove oven drawer The tops of level ing legs will be exposed as shown Use a allen wrench to raise or lower legs as needed IMPORTANT Oven must be properly leveled for satisfactory baking conditions B Remove shipping clips Each of the 4 elements is secured by a shipping clip Using screwdriver or pliers bend upper part of the clip to vertical position Slide clip out and discard it C Complete electrical connection Back appliance away from wall leaving room to make connection Plug flexible pigtail into ap proved receptacle if allow ed by local codes OR Connect flexible armored or non metallic shielded cable directly to fused disconnect box 5 Check operation CAUTION Do not touch any heating elements They may be hot and you may be burned A Surface elements Turn on each of the 4 surface elements Check to be cer tain they heat and check for proper operation of surface indicator light s B Oven elements BAKE Set selector switch on BAKE Turn thermostat to 3500 BAKE The bottom element should glow red and in dicator light should be on The upper element should become
12. rom range before use A Remove shipping skid CARDBOARD PADS UNDER APPLIANCE Remove the 4 cardboard pads from shipping box Place them on floor as shown to protect appliance s finish Rest appliance on its back on pads Remove the two 3 8 shipping bolts from wooden skid Discard the skid B Extend leveling legs I LOOSEN WITH A ADJUSTABLE WRENCH BOTTOM OF LEVELING LEG Once skid is removed 4 leveling legs are exposed at bottom of frame Loosen legs by applying an adjustable wrench to the 1 base of the leveling legs Back each of them out about 4 complete turns Stand appliance on its base Begin electrical connection Grounding Instructions WARNING THIS APPLIANCE MUST BE CONNECTED TO A GROUNDED METALLIC PERMANENT WIRING SYSTEM OR AN EQUIPMENT GROUNDING CON DUCTOR SHOULD BE RUN WITH THE CIRCUIT CONDUCTORS AND CONNECTED TO THE EQUIP MENT GROUNDING TERMINAL OR LEAD ON THE APPLIANCE WARNING IT IS CUSTOMER S RESPONSIBILITY TO CONTACT A QUALIFIED ELECTRICAL INSTALLER eTO ASSURE THAT ELECTRICAL INSTALLATION IS ADEQUATE AND IN CON FORMANCE WITH NATIONAL ELECTRICAL CODE AND LOCAL CODE ORDINANCES CAUTION Before connecting flexible armored cable for permanent wiring disconnect power at fuse box or circuit breaker A Remove terminal block cover IB BRASS NUTS UNDER TAPE TERMINAL BLOCK COVER eer RETAINING SCREWS Tea LE EL DEE OA e ETE ATE M
Download Pdf Manuals
Related Search
Related Contents
AXIS 213 PTZ User Guide - Intelligent Security & Fire Ltd USER`S MANUAL - Minarik Drives ユーザーズマニュアル [PDF形式] Copyright © All rights reserved.
Failed to retrieve file