1. 4 i i ee Turn vent baffle and reinsert in slot in top of range hood so that the word Vented is facing up Fasten vent baffle with screws 5 wiring knockouts E Remove knockout from the wiring opening top or rear to be used For rectangular venting remove only the 3 1 4 x 10 rectangular opening knockout For round ductwork venting through roof remove both opening knockouts knockouts Remove terminal box cover from range hood AA WARNING Personal Injury Hazard More than one person is required fo help with appliance installation because of ifs weight and size Numbers Failure to follow these instructions may correspond 6 16 result in personal injury to sieps l To vent through wall with 3 1 4 x 10 rectangular ductwork measure from floor 65 7 8 and 62 3 8 Cor 1 8 and 3 5 8 down from underside of cabinet and mark on back wall Measure and mark a line 5 1 4 to right and left of centerline connecting the two lines Use a saber saw to cut a rectangular opening for the ductwork 11 install ductwork through the vent opening in upper cabinet or wall Complete venting system according to method needed See mark Keyhole siots 7 Lift the range hood into final W position and center Mark on the underside of cabinet the location of the four keyhole mounting slots Set range hood aside on a protected surface centerline To wire through rect mark a line 7 1 2 from the
2. 6 ft gt wall cap 90 elbow 2 ft a 2 3 1 4 x 10 Maximum length 26 iol Aire 1 transition 45 ft eer 2 90 elbows 10 ft 8 feet straight 8 ff 1 wall cap 0 ff Length of 7 system 22 5 ft Recommended standard fittings 7 to 3 1 4 x 10 90 elbow 9 ft 3 1 4 x 10 to 7 3 1 4 x 10 to 5 ft 90 elbow 5 ft 7 4 7 wall cap 0 ft 7 to 3 1 4 x 10 1 ft 90 elbow 45 elbow 5 ft 2 5 ft Now start With range hood in kitchen A CAUTION Property Damage Slide cardboard or hardboard under range before moving range across floor Failure to do so could cause damage to floor covering Cover countertop cooktop or set in range with a thick protective covering Failure to do so may result in property damage 4 Disconnect and move freestanding E range from cabinet opening to provide easier access to upper cabinet and rear wall Put a thick protective covering over cooktop set in range or countertop to protect from damage or dirt 2 Determine which venting method E roof or wall venting or non venting you need to use This range hood is shipped for non vented installation if non venting recirculating installation is desired follow instructions on Panel D Vented installation Remove screws from vent baffle on top of range hood Remove vent baffle
3. during range hood operation before cleaning or servicing Filter light lens For best results remove and clean often To remove filter light lens fan control light control filter tab Pull firmly on filter tab to remove filter light lens from range hood To clean filter light lens Place filter light lens in dishwasher or hot sudsy water to clean Non vented installation Turn filter lignt lens so that charcoal filter pad is facing up Lift tabs and remove charcoal filter pad Discard charcoal filter pad Place filter lignt lens in dishwasher or hot sudsy water to clean Lift tabs and place new charcoal filter pad in filter light lens New charcoal filter pads Part No 883151 are available from your dealer To reinstall filter light lens Place edge of filter light lens in opening so that right side is above flange and tab faces downward Press filter lignt lens into position To clean fan motor Every three years lubricate each motor bearing with a few drops of oil to help prolong motor life Clean exterior of motor with a damp cloth and grease cutting detergent Exterior surfaces Clean the range hood with a mild detergent and soft cloth Do Not use abrasive cleansers or steel wool pads Light Do Not use bulb larger than 60 watts in light socket Light bulb is not included Panel E If you need assistance The Whirlpool Consumer Assistance Center will answer any questions about
4. right of the centerline on the wall Mark the point on this ine that is 64 5 8 from the floor or 1 3 8 from underside of cabinet Drita 1 1 4 diameter hole through wall at this point cabine centerline 12 Attach rectangular damper to selected rectangular vent opening If damper is attached fo pack of range hood be sure grea the veni opening will be made 4 Oo damper hinge is toward the top For round a vented installati Determine and clearly mark a vertical centerline on the wall and cabinet inthe ons use round damper in duct fo prevent air from flowing back into To vent through the roof with 7 round s ductwork If roof cap has a damper ductwork mark 4 J gt and 5 in from back wall along the centerline on underside of remove damper blade from range hood cabinet Use these points as centers TO draw 7 1 8 circles on underside of cabinet 4 3 i Use a saber saw to cut the openings for the u ductwork Repeat for tne underside of the Run wiring through wall or cabinets i i 1 378 top of the cabinet This will create slotted according to the National Electrical Code i from openings and local codes and ordinances Do Not l wall turn on power until installation is complete i Vi cabinet cutouts i keyhole slot centerline screw 14 Start screws through neck of each of the four keyhole mounting screw slots marked To wire through top mark a line 7 1 2 from the right of
5. terminal box with a twist on wire connector Use caulking to seal wire opening Replace terminal box cover Pull firmly on tab to remove filter light lens from range hood Turn filter light lens so that charcoal filter pad is facing up Lift tabs and remove charcoal fiter pad Discard charcoal filter pad Place edge of filter light lens in opening so that right side is above flange and tab faces downward Press filter light lens into position Panel D Non vented installation Check vent baffle on top of range hood Non vented should be facing up 2 Remove knockout from the wiring opening rear or top to be used Do Not remove venting knockouts terminal KAY YOR aK KAN XAN OXA BY Remove terminal box cover on range hood WARNING Personal Injury Hazard More than one person is required to heip with appliance installation because of its weight and size Failure to follow these instructions may result in personal injury keyhole slot 4 Lift range hood into final position and center Mark on underside of cabinet the location for the four keyhole mounting slots Set range hood aside on a protected surface Determine and clearly mark a vertical centerline in the area the vent opening will be made centerline To wire through top mark a line 7 1 2 from the right of the centerline on the underside of the cabinet Mark the point on this line that is 1 3 8 from
6. the centerline on the underside of the cabinet Mark the point on this ine that is 1 3 8 from back wall Drill a 1 1 4 Se a hole through the cabinet at this on the cabinet botom point a 15 Lift range hood into final position feeding To vent through the roof with 3 1 4 x 10 electrical wire through wiring opening rectangular ductwork mark a line 1 and 5 Position the range hood so that the large from the back wall on the underside of the end of the keyhole slots are over the screws cabinet Mark lines 5 1 4 to the right and Then push the hood toward the wall so that left of the centerline on the underside of the screws are in the neck of the slots cabinet that connect the lines just drawn Use a saber saw To cut a rectangular opening for the ductwork Repeat for the underside of the top of the cabinet making sure mounting screws are in narrow neck of slots Make sure that damper blade if used rotates up and down freely Panel C i cal white green grounding E screw Se SSeS eose ISSSSS SSSA Ose esos S54 amp SOS BSS poSo eS PESES 55 yey gt lt C2 SS CS C Ss LSe SSeS lt lt gt l gt Oe Qx a grounding 16 Remove terminal box cover Connect the white and black wires of the power supply cable to the white and black leads in the hood with twist on connectors Connect the power supply grounding wire to the green grounding wire inside the range
7. D The range hood should be E connected directly to the fused disconnect or circuit breaker box through flexible armored or nonmetallic sheathed copper cable A U L listed strain relief must be provided at each end of the power supply cable Wire sizes COPPER WIRE ONLY and connections must conform with the rating of the appliance as specified on the serial rating plate Wire sizes must conform to the requirements of the National Electrical Code ANSI NFPA 70 latest edition and all local codes and ordinances Venting requirements A WARNING Fire Hazard e Terminate venting system to outside Do Not terminate the vent in an attic or other enclosed space Failure to follow these instructions could result in a fire Ductwork needed for installation is not included If roof or wall cap has a damper Do Not use damper supplied with hood Determine which outside venting method needs to be used NOTE If a non vented recirculating installation is desired follow instructions on Panel D The length of the ductwork and number of elbows should be kept to a minimum to provide efficient performance The size of the ductwork should be uniform Do Not install two elbows together Use duct tape to seal all joints in the ductwork system Ductwork can terminate either through the roof or wall Use caulking to seal exterior wall or roof opening around exhaust hood For the most efficient and quiet operation it is reco
8. installation Instructions A _ DP IMPORTANT Part No 626701 883147 Rev F Read and save E 30 and 36 Convertible Range Hood IMPORTANT Installer Leave Installation Instructions with homeowner Homeowner Keep Installation Instructions for future reference Save installation Instructions for electrical inspector s use Before you start Proper installation is your responsibility Make sure you have everything necessary for correct installation It is the responsibility of the installer fo comply with the clearances specified 30 modei 29 7 8 36 model 35 7 8 10 vent baffle knockouf for rectangular top vent 19 3 4 Grounded electric 1 3 8 outlet is required See Electrical requirements wiring knockouts Knockout for 7 round Check the location where the range hood Will be installed The location should be away from strong draft areas such as windows doors and strong heating vents rear of hood AWARNING Electrical Shock Hazard It is the customer s responsibility To contact a qualified electrical installer e To assure that the electrical installation is adequate and in conformance with National Electrical Code ANSI NFPA 70 latest edition and all local codes and ordinances Failure to do so could result in fire electrical shock or other personal injury Care must be taken when drilling holes into wa
9. l damages so this limitation or exclusion may not apply to you This warranty gives you specific legal rights and you may also have other rights which vary from state to state Outside the United States a different warranty may also apply For details please contact your franchised Whirlpool distributor or military exchange ifl CORPORATION Part No 626701 883147 Rev F 1994 Whirlpool Corporation Prepared by Whirlpool Corporation Benton Harbor Michigan 49022 If you need service In the event your Whirlpool appliance should need service call the dealer from whom you purchased the appliance or a Whirlpool authorized service company A Whirlpool authorized service company is listed in the Yellow Pages of your phone directory under Appliance Household Major Service or Repair You can also obtain the service company s name and number by dialing free within the continental United States the Whirlpool Consumer Assistance Center number 1 800 253 1301 A special operator will tell you the name and number of your nearest Whirlpool authorized service company Maintain the quality built into your Whirlpool appliance call a Whirlpool authorized service company Printed on recycled paper 10 post consumer waste 50 recovered materials Printed in U S A
10. ll Electrical wires may be concealed behind the wall covering Failure to do so could result in electrical shock or other personal injury Personal Injury Hazard Reaching over a heated cooking surface should be avoided To reduce the hazard of being burned the range hood should extend a minimum of 5 inches out from the bottom of the cabinet Reaching over a heated cooking surface could result in a serious burn Important Observe all governing codes and ordinances Tools and materials needed for installation b saber or keyhole saw Phillips screwdriver 1 1 4 drill bit a gt compass or 7 ruler circle template Mobile home installation The installation of this range hood must conform to the Manufactured Home Construction Safety Standards Title 24 CFR Part 3280 formerly the Federal Standard for Mobile Home Construction and Safety Title 24 HUD Part 280 or when such standard is not applicable the Standard for Manufactured Home Installation 1982 Manufactured Home Sites Communities and Setups ANSI A225 1 1987 or latest edition or with local codes Four wire power supply must be used and the appliance wiring must be revised See Electrical requirements Copies of standards listed may be obtained from National Fire Protection Association Batterymarch Park Quincy Massachusetts 02269 Panel A knockout for back vent 7 1 2 damper mounting holes Electrical requi
11. mmended that the range be vented vertically through the roof through 7 round ductwork Figures 1 4 show common venting methods and what types of materials are needed Vertical Roof Venting roof cap 7 round ne through the as roof TJ damper located as far from hood as possible 66 Figure 1 Vertical Roof Venting roof cap 3 1 4 x 10 through the roof Figure 2 Horizontal Wali Venting 3 1 4 x 10 through the wall Figure 3 Panel B 7 min diameter round ductwork x Wall cap eur B elbow 1 grr on gt tt moi 3 3 1 4 x 10 to round oo NLA e zs ductwork transition to 3 1 4 x 10 to round ductwork transition Figure 4 Recommended ductwork length Use 3 1 4 x 10 or 7 ductwork with a maximum length of 26 feet for ductwork system For best performance use no more than three 90 elbows To calculate the length of system you need add the equivalent feet for each ductwork piece used in the system See the following examples 3 1 4 x 10 ductwork system 3 1 4 x 10 lt tt gt elbow Maximum length 26 feet 2ft 1 90 elbow 5 ft 8 feet straight Ef 1 wall cap Oft Length of 3 1 4 x 10 system 13 ff Recommended standard fittings 3 1 4 x 10 flat 3 1 4 x 10 wall elbow 12 ft cap 0 ft 3 1 4 x 10 90 elbow 5 ft 7 ductwork system lt
12. operating or maintaining your range hood not covered in the Installation Instructions The Whirlpool Consumer Assistance Center is open 24 hours a day 7 days a week Just dial 1 800 253 1301 the call is free When you call you will need the range hood model number and serial number Both numbers can be found on the underside of the range hood Whirlpool Range Hood Warranty FULL ONE YEAR WARRANTY FSP replacement parts and repair labor to correct From Date of Purchase defects in materials or workmanship Service must be provided by an authorized Whirlpool service company If range hood does not operate Check that the circuit breaker is not tripped or the house fuse blown WHIRLPOOL WILL NOT PAY FOR A Any labor costs incidental to the replacement of defective parts B Consumable parts such as light bulbs and filters C Service calls to 1 Correct the installation of the range hood 2 Instruct you how to use the range hood 3 Replace house fuses or correct house wiring D Repairs when range hood is used in other than normal single family household use E Pickup and delivery This product is designed to be repaired in the home F Damage to range hood caused by accident misuse fire flood act of God or use of products not approved by Whirlpool WHIRLPOOL CORPORATION SHALL NOT BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES Some states do not allow the exclusion or limitation of incidental or consequentia
13. rements AWARNING Electrical Shock Hazard Electrical ground is required on this appliance Do Not ground to a gas pipe e Do Not modify the power supply cord plug If it does not fit the outlet have a proper outlet installed by a qualified electrician Do Not have a fuse in the neutral or grounding circuit A fuse in the neutral or grounding circuit could result in an electrical shock Do Not use an extension cord with this appliance Check with a qualified electrician if you are in doubt as to whether the appliance is properly grounded Failure to follow these instructions could result in serious injury or death If codes permit and a separate grounding wire is used it is recommended that a qualified electrician determine that the grounding path is adequate A A 115 volt 60 Hz AC only fused E electrical supply is required The total ampere load used including the range hood must not exceed 90 of the rated capacity of the circuit The ampere rating of the range hood Is located on the serial rating plate located on the underside of the range hood BR It is the personal responsibility and E obligation of the customer to contact a qualified electrician to assure that the electrical installation is adequate and in conformance with the National Electrical Code ANSI NFPA 70 latest edition and all local codes and ordinances The range hood must be Mm connected with copper wire only
14. the back wall Drill a 1 1 4 diameter hole through cabinet at this point centerline To wire through rear mark a line 7 1 2 from the right of the centerline on the wall Mark the point on this line that is 64 5 8 from the floor or 1 3 8 from underside of cabinet Drill a 1 1 4 diameter hole through wall at this point T Replace terminal box cover Continue installation with Step 13 Panel C You have just finished installing your new Whirlpool range hood Keep installation Instructions close to range hood for easy Congratulations reference The instructions will make reinstalling your Whirlpool range hood in another home as easy as the first installation Use amp Care Operation 6 Information of range hood For best results turn range hood fan ON at beginning of cooking and allow it to run 44 WAR N NG until all smoke and odors are removed from room Electrical Shock Hazard To prevent the risk of electrical shock or To turn fan ON HIGH and LOW injury be sure to disconnect power Turn fan control to turn fan to HIGH LOW and OFF Speed may be increased or If any electrical problem becomes Sater a Same ADEN ange Ngoa evident during use disconnect power to hood at fuse or breaker box To turn range hood light ON and OFF R Turn light control to turn light ON or OFF Failure to follow these instructions could Light may be turned to OFF or ON anytime result in electrical shock
Download Pdf Manuals
Related Search
Related Contents
Huawei MediaPad 10 FHD 16GB 3G 4G Silver Soirée festive Animations Musique, chant ZM7999 PCソフトウェア Betriebanleitung Zeus Schweißerschutzhelm BT DP-01 - WATTS industries Dlink DSL-2640B-SEA-1.00 Manual Mixing Ratios for the Proposed National VOC Rule and Similar Rules. IBIX flexP.2.7 - IBIX Informationssysteme GmbH oven/steamer Copyright © All rights reserved.