Home

Vermont Casting ICVCTK01 Indoor Fireplace User Manual

image

Contents

1. 4 Electrical CONNEC as kk se 4 Grounding instructions a 4 Direct Hard Wiring Electric Fireplace 5 Fireplace Assembly Unpack the 6 Carton u U u uuu u 6 Appliance MOUNTING sessionen e RE 6 Heater ASSCMDIY uu a sl AET 6 Ti SASSO e E E e E sss 6 Operating Instructions Heater operation 8 Frequency setting information 8 Maintenance Light bulb replacement la ason doz ke ou b 9 Gare and CICANING z Mi 9 Replacement Parts 10 biin 11 2 10009472 Installation Instructions General 1 Read all instructions before using this appliance 2 This appliance is hot when in use To avoid burns do not let bare skin touch hot surfaces If provided use handles when moving this appliance Keep combustible materials such as furniture pillows bedding papers clothes and curtains away at least 3 914 mm from the front of this appliance 3 CAUTION Extreme caution is necessary when any heater is used by or near children or invalids and whenever the heater is left operating unattended 4 If possible
2. INTERCONTINENTAL COLLECTION Ev verwonr castinas Inspire Electric Fireplace Model ICVCEFP01 Trim Models ICVCTKO1 Black Trim Kit ICVCTKO2 Pewter Trim Kit INSTALLER CONSUMER SAFETY INFORMATION PLEASE READ THIS MANUAL BEFORE INSTALLING AND USING APPLIANCE WARNING IF THE INFORMATION IN THIS MANUAL IS NOT FOLLOWED EXACTLY AN ELECTRICAL SHOCK OR FIRE MAY RESULT CAUSING PROPERTY DAMAGE PERSONAL INJURY OR LOSS OF LIFE FOR YOUR SAFETY Service must be performed by a qualified service D agency DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE LIQUIDS IN THE VICINITY OF THIS US OR ANY OTHER APPLIANCE 10009472 12 06 Rev 2 Inspire Electric Fireplace Thank you and congratulations on your purchase of a CFM Corporation electric fireplace IMPORTANT Read all instructions and warnings carefully before starting installation Failure to follow these instructions may result in a possible electric shock fire hazard and will void the war ranty PLEASE READ THE INSTALLATION amp OPERATING INSTRUCTIONS BEFORE USING THIS APPLIANCE Table of Contents Installation Instructions SOR CA ba raket aa n T kb zo in sapu u apa ese 3 kocating your fireplace kek 3 Clearance to combustibles 3 Fireplace dimensions 4 Electrical Specifications
3. 10009472 9 Inspire Electric Fireplace CFM Corporation reserves the right to make changes in design materials specifications prices and discontinue colors and products at any time without notice Inspire Replacement Parts Ref Description 20W Energy Saving Bulb Pebble Pack not shown Colored Filter Ember Lava Rock Circuit Board Transmitter Fan Heater Flame Blower Power Cord Landscape Electric Screen Alternate 20W Energy Saving Bulb Sylvania CF20EL 830 MED 1 10 Part Number B 98830 B 81770 B 99670 B 93420 B 99610 B 100990 1097 99660 B 99580 B 99590 B 91130 10009472 Inspire Electric Fireplace 1 YEAR WARRANTY For Vermont Castings Electric Fireplace BASIC WARRANTY CFM Corporation hereinafter referred to collectively as the Company warrants that your new electric fireplace is free from manufacturing and material defects for a period of one year from date of installation subject to the following conditions and limitations 1 This electric fireplace must be installed and operated at all times in accordance with the Installation and Operating in structions furnished with the product Any alteration willful abuse accident or misuse of the product shall nullify this warranty 2 This warranty is non transferrable and is made to the original owner provided that the purchase was made through an authorized supplier of the Company 3 This warra
4. elec trical shock and injury to persons 145 mm Minimum 250 mm From Floor A 51 46 97 mamam 1 Do not use this fireplace if any part of it has been under water Immediately call a qualified service technician to inspect the fireplace and replace any part of the elec trical system which has been under water Grounding Instructions This heater is for use on 120 volts The cord has a plug as shown at Ain Figure 1 An adapter as shown at is available for connecting three blade grounding type plugs to two slot receptacles The green grounding lug extending from the adapter must be connected to a per manent ground such as a properly grounded outlet box The adapter should not be used if a three slot grounded receptacle is available P s Cover of Grounded Outlet Box Grounding Pin A N Metal Screw Grounding Means FP1636 Fig 1 Grounding methods 10009472 Direct Hard Wiring Electric Fireplace WARNING This procedure must be conducted by a qualified electrician in accordance with National and local codes In the U S A the installation must conform to the National Electrical Code ANSI NFPA No 70 In Canada the installation must conform to the current CSA C22 1 Canadian Electrical Code WARNING Make sure the power to the unit is off and the power cord is unplugged from the wall outlet before proceeding with this conversion Failure to do so
5. haust in any manner Do not use on soft surfaces like a bed where openings may become blocked 16 This appliance has hot and arcing or sparking parts inside Do not use it in areas where gasoline paint or flammable liquids are used or stored This appliance should not be used as a drying rack for clothing nor should Christmas stockings or decorations be hung on or near it 17 Use this appliance only as described in this manual Any other use not recommended by the manufacturer may cause fire electric shock or injury to persons 18 Avoid the use of an extension cord because of the risk of overheating the cord and the risk of fire Extension cords are for temporary use only If an extension cord must be used it must be UL CSA certified rated at 15A 1875W 125 V maximum with 14 AWG minimum and constructed of two current carrying conductors with ground A heavy duty extension cord with the shortest length possible for this connection is recommended and must not be longer than 50 ft 15 2 m Do not coil or cover the extension cord Locating Your Fireplace When choosing a location for your new fireplace en sure the general instructions are followed Also for best effect install the fireplace out of direct sunlight Clearance to Combustibles Sides including trim assembly 0 0 mm AE 978 250 mm aqaqassa 3 914 mm Unit EFHI4SO S
6. may result in property damage personal injury or loss of life This instruction is intended as a guide for replacing the power cord supplied with the electric fireplace with direct hard wiring NOTE When direct wiring this appliance it must be connected to a 15 Amp dedicated circuit breaker or fuse in the electrical panel of the dwelling The cable between the circuit fuse panel and the fireplace must meet all local and national codes and in no case shall the wires be less than 14 gauge 1 Make sure the power to the unit has been turned off the master ON OFF switch located under the appliance on the left hand side is turned off the power cord is unplugged from the wall outlet and the appliance has cooled down 2 Follow Steps 1 through 4 in Light Bulb Replacement section Page 9 3 Remove two 2 screws per side for the brackets and the fireplace screen to be removed and set aside 4 Remove one 1 screw per side of the bulb housing assembly to remove and set aside 5 Remove two 2 screws per side for the left side cover This allows the cover to be opened for access to where the power cord enters the strain relief and the compartment 6 Using wire cutters gently cut the power cord inside the compartment flush to the strain relief Also repeat for the power cord outside the compartment 7 Back inside the compartment gently separate the three 3 wires of the power cord into separate wires by gently pulling
7. white of the power cable to the power cord ending at the screw clamp terminal block of the circuit board It is recommended that the wire nuts be taped to the wires using electrical tape as an extra safety mea sure 12 For extra safety measure visually check and fix the wire routing appropriately Refer to the wiring dia gram on the unit or in the instruction manual if any wires have been dislodged 13 Turn the power to the unit on at the breaker fuse panel Place the appliance into operation and check to make sure all of the systems are working prop erly Inspire Electric Fireplace Fireplace Assembly Unpack the Appliance The Inspire Electric Heater is supplied in two 2 car tons All instructions should be read before beginning installation Carton 1 contents 1 Electric heater main body 1 Remote control handset with battery 1 Mounting hanger 1 Mounting hardware kit 12 x 1 2 long screws 6 wall anchors 6 8 x 1 4 short screws 4 1 Installation instructions 1 Pebble pack 2 Insert panels Carton 2 contents 1 Trim assembly w six 6 magnets Appliance Mounting The heater must be mounted to a suitable wall using the mounting hanger provided Consider the minimum clearance dimensions referenced on Page 3 and 4 for the mounting location The following steps are for one method that can be used at your own risk A helper is recommended 1 Become familiar with the mountin
8. AVE THESE INSTRUCTIONS 10009472 Inspire Electric Fireplace Fireplace Dimensions F 247 52 2336 615 mm Minimum Shelf Height 36 To Heater Main Body 914 mm 594 mm ke 35 910 mm Heater Main Body Width 3294 832 mm Electrical Specifications Voltage 120V ac 60 Hz Total Amps 7 9 Amps Total Watts 1050W Heater Rating 2 x 500W Illumination 2 x 20W Low Energy Bulb Electrical Connection 15 amp 120 Volt 60 Hz circuit with a properly grounded outlet is required Preferably the fireplace will be on a dedicated circuit as other appliances on the same circuit may cause the circuit breaker to trip or the fuse to blow when the heater is in operation The unit comes standard with a 6 ft 1 8 m long three wire cord exiting the left side of the fireplace Plan the installa tion to avoid the use of an extension cord Extension cords are for temporary use only If an extension cord must be used it must be UL CSA certified rated at 15A 1875W 125V maximum with 14 AWG minimum and constructed of two current carrying conductors with ground A heavy duty extension cord with the shortest length possible for the connection is recommended and must not be longer than 50 ft 15 2 m Do not coil or cover the extension cord Electrical outlet wiring must comply with A local building codes and other applicable regulations to reduce the risk of fire
9. always unplug this appliance when not in use 5 Do not operate any heater with a damaged cord or plug or after the appliance malfunctions has been dropped or damaged in any manner 6 Any repairs to this appliance should be carried out by a qualified service person 7 Under no circumstances should this appliance be modi fied Parts having to be removed for servicing must be replaced prior to operating this fireplace again 8 Do not use outdoors 9 This heater is not intended for use in bathrooms laun dry areas and similar indoor locations Never locate this appliance where it may fall into a bathtub or other water container 10 Do not run cord under carpeting Do not cover cord with throw rugs runners or the like Arrange cord away from traffic areas and where it will not be tripped over 11 To disconnect this appliance turn controls to the off posi tion then remove plug from outlet 12 Connect to properly grounded outlets only Inspire Electric Fireplace 13 This appliance when installed must be electrically grounded in accordance with local codes with the current CSA C22 1 Canadian Electrical codes or for US installa tions follow local codes and the National Electric Code ANSI NFPA No 70 14 Do not insert or allow foreign objects to enter any venti lation or exhaust opening as this may cause an electric shock fire or damage the appliance 15 To prevent possible fire do not block air intakes or ex
10. d places it in a standby mode Example of Frequency Setting Switch Set ON ON OFF ON Dial Set C NOTE The frequency setting of the RF transmitter label affixed on the lower left front of the unit must match the dial setting on the rear of the remote control handset 10009472 Inspire Electric Fireplace Maintenance WARNING Before carrying out any maintenance ensure the appliance is disconnected from the main power supply If in doubt seek the assistance of a quali fied technician It is advisable to use genuine CFM Corporation replace ment parts available from your authorized dealer Light Bulb Replacement 1 Disconnect the appliance from the main power sup ply 2 Remove the decorative trim assembly 3 Remove the pebbles and ember bed 4 Remove the removable panel by unscrewing the four 4 screws Fig 6 5 Remove the colored filter from the bulb and unscrew the bulb from its housing Fig 7 Remove Screws 6 Install the new 20W light bulb 7 Reassemble in reverse order FP1640 Fig 6 Removable panel Care and Cleaning Always disconnect the appliance from the main power supply and allow to cool before any cleaning operation begins Metal painted parts may be cleaned using a clean damp cloth Never use any abrasive cleaners and chemical agents as these may damage the paint finish Light Bulb Light Bulb Color Film FP1643 Fig 7 Remove color film and remove light bulbs
11. d to turn the appliance completely off All further operations are controlled by using the remote control handset Fig 5 1 Ensure the appliance is plugged in and switched on 2 To turn the fire on press the fire on flame effect but ton 3 For low heat ensure the flame effect is on and press the low heat button once To turn the low heat off press the low heat button a second time The fire will now be running with flame effect only 4 For high heat ensure the flame effect and low heat settings have been switched on Press the high heat button The high heat button will only work if the flame effect and low heat have already been switched on To turn high heat off press the high heat button a second time The fire will now be run ning with low heat 5 To place the fire in a standby mode at any time press the fire off button Frequency Setting Information Dial Set A Switch Set ON ON ON ON ON ON ON OFF ON ON OFF ON ON ON OFF OFF ON OFF ON ON N OFF ON OFF N OFF OFF ON N OFF OFF OFF FF ON ON ON FF ON ON OFF FF ON OFF ON FF ON OFF OFF OFF OFF ON ON OFF OFF ON OFF OFF OFF OFF ON OFF OFF OFF OFF 2 A B D S 1 M N O Fire On Flame Effect Only Fire Off Low Heat On Off High Heat FP1639 Fig 5 Remote control handset Switch Marking Master ON OFF O Operation On Off Depress to this supplies power to the appliance an
12. eplace has been operated in atmospheres contaminated by chlorine fluorine or other damaging chemicals b The fireplace is subjected to prolonged periods of dampness or condensation c Any alteration willful abuse accident or misuse of the product IF WARRANTY SERVICE IS NEEDED 1 Contact your supplier Make sure you have your warranty your sales receipt and the model serial number of your CFM Corporation product 2 DO NOT ATTEMPT TO DO ANY SERVICE WORK YOUR SELF 11 CFM Corporation 2695 Meadowvale Blvd Mississauga Ontario Canada L5N 8A3 800 668 5323 www cfmcorp com
13. g hanger and how it fits to the rear of the electric heater main body Fig 2 Mounting Hanger Wiring Diagram Fig 2 Rear view of Inspire with mounting hanger in place 2 Locate the heater main body on the wall and mark erasable either the bottom or top edge and one side for the heater location If the heater is to be centered on the wall area the side mark is not nec essary Set the heater main body down 3 Mark a horizontal line 21 536 mm from the lower line or 2 58 mm from the upper line 4 Measure half the width 1638 416 mm of the heater main body and mark a vertical line to cross the horizontal line If the heater main body is to be centered on the wall area mark a vertical center line to cross that horizontal line Where the horizontal and vertical marks cross is the location of the upper center mounting hanger hole 5 Use an appropriate level and mark and measure the locations for the remaining holes of the mounting hanger Use the mounting hanger as a template 6 Use the long screws provided to mount the hanger in place A 3 Phillips screwdriver is recommended Depending on the wall type proper anchors have to be used For your convenience expansion anchors are provided Be sure to check the anchors for suit ability for the wall type 7 Mount the heater main body to the hanger Heater Assembly Before assembling the trim to the heater main body arrange the pebbles onto the plas
14. nty is limited to the repair or replacement of part s found to be defective in material or workmanship provided that such part s have been subjected to normal conditions of use and service after said defect is con firmed by the Company s inspection 4 This warranty does not cover the lightbulb s included with the fireplace 5 The Company may at its discretion fully discharge all obligations with respect to this warranty by refunding the wholesale price of the defective part s 6 Any installation labor construction transportation or other related costs expenses arising from defective part s repair replacement or otherwise of same will not be covered by this warranty nor shall the Company assume responsibility for same Further the Company will not be responsible for any incidental indirect or consequential damages except as provided by law 10009472 7 All other warranties expressed or implied with respect to the product its components and accessories or any ob ligations liabilities on the part of the Company are hereby expressly excluded 8 The Company neither assumes nor authorizes any third party to assume on its behalf any other liabilities with respect to the sale of this Vermont Castings product 9 The warranties as outlined within this document do not ap ply to non CFM Corporation accessories used in conjunc tion with the installation of this product This warranty is void if a The fir
15. them apart DO NOT use a knife as this may expose bare conductors The hot wire 10009472 Inspire Electric Fireplace is connected to the main power switch and is termi nated with a straight terminal connector The neutral wire is connected at the circuit board s screw clamp terminal block The green ground wire is attached to the ground stud Use a 5 16 8 mm socket or wrench to remove the brass nut brass lock washer and brass cup washer and set aside Remove and discard the cut power cord ground wire Warning Make sure the power to the power cable has been turned off at the breaker fuse panel before proceeding 8 Using a slotted screwdriver remove the 7 8 22 mm diameter knockout above the old power cord strain relief 9 Route the power cable from the breaker fuse panel through the 7 8 22 mm diameter hole Secure the cable to the compartment using an approved clamp The wires should extend approximately 6 152 mm into the compartment 10 Connect the ground wire from the power cable by wrapping it around the ground stud of the unit and securing it firmly with the brass cup washer brass lock washer and brass nut Using wire strippers strip approximately 5 8 15 mm from the ends of the hot and neutral wires Using an approved wire nut connect the hot lead black of the power cable to the power cord wire that ends at the main power switch Similarly using another wire nut connect the neutral wire
16. tic front form ember lava rock to give the best decorative effect Refer to front cover for example If necessary the side brackets for the plastic front form may need to be removed to fit and reinstall Trim Assembly Place the trim insert panels on either side of the trim and secure to the trim using the screws provided Two 2 screws on either side 1 Remove the protective plastic bag and place the trim on it to prevent any damage to the front while work ing 2 Peel off the protective plastic coating if available on the insert panel 3 Place the insert panel on either side as shown in Figure 3 Secure each panel using two 2 short screws The screws fit into slots in the trim A me dium 2 Phillips screwdriver is recommended 4 Double the six 6 magnets and place on the trim in three locations as shown in Figure 4 10009472 Inspire Electric Fireplace Insert Panel FP1638 Fig 3 Place insert panels on either side of trim FP1637 5 Hang the trim to the heater main body s upper trim Fig 4 Trim magnet location support at a slight angle and between the trim insert panels Slowly swing the trim down until the mag nets catch to the heater main body 10009472 7 Inspire Electric Fireplace Operating Instructions Heater Operation The heater is operated by the remote control handset A master ON OFF switch is located under the appliance on the left hand side This is use

Download Pdf Manuals