Home

U-Line CLR2060 Ice Maker User Manual

image

Contents

1. Unit is not level Low air temperature around unit Poor incoming water quality Ice making system is dirty Low water level Hot incoming water Incorrect incoming water pressure Unit is not level Clean unit See MAINTENANCE Remove items blocking airflow Run unit through automatic clean cycle See MAINTENANCE See LEVELING THE UNIT Surrounding air temperature must be at least 50 F 10 C Consult a qualified plumber to test the water quality and recommend appropriate treatment Run unit through automatic clean cycle See MAINTENANCE Check to see that overflow tube is fully seated Connect the unit to a cold water supply See INSTALLATION Water pressure must be 20 120 psi See LEVELING THE UNIT a User s Manual Possible Cause Water leaking Supply line leaking Check to see that water from under the inlet line is attached to unit inlet valve properly See CONNECTING THE WATER SUPPLY Fill tube leaking Check connection at water valve outlet Bin drain leaking Check integrity of bin drain hose and clamp Ice storage bin Obstructed drain Check to see that full of water storage bin drain opening is free from obstruction and debris IF SERVICE IS REQUIRED If the need for service arises contact the dealer from whom the unit was purchased State the Model Number and Serial Number and explain the problem The Model and Serial Number plate is located
2. Y UO LINE Remove 12 screws and back panel Check that the clamps and hose connections are tight at the fol lowing areas e Discharge tube A e Drain tube B e Vent tube C BACK VIEW SIDE VIEW UL184 2 Place a suitable container beneath the pump s discharge tube The bucket must be able to hold a minimum of one gallon 10 T1 Plug the ice maker power cord into a properly grounded polarized electrical outlet Verify pump operation by pouring one gallon of water into the ice storage bin of the ice maker The pump should energize and pump the water into the container At this time verify that all tube and clamp connections are tight and leak free Unplug unit power cord from electrical outlet Leave back panel off for water supply line installation Continue to the next step in the installation process SITE PREPARATION User s Manual CONNECTING A DRAIN PUMP If a gravity drain connection is not available and you have not pur chased the CLR2060 with factory installed pump we strongly rec ommend the use of the U Line P60 drain pump The U Line P60 drain pump is available through your Dealer or direct from U Line with com plete installation instructions If a pump other than the U Line P60 drain pump is to be used it must meet the following specifications e It must be UL listed and have a UL listed 120 VAC 3 wire ground ed power cord e It must have overall maximum
3. e Do not lift unit by door handle e Use care when moving the unit Some edges are sharp and may cause personal injury Wear gloves when mov ing or repositioning the unit e Never install the unit behind closed doors Be sure front grille is free of obstruction Obstructing free air flow can cause the unit to malfunction and may void the warranty e Allow unit temperature to stabilize for 24 hours before use e Never use an ice pick or other sharp instrument to help speed up defrosting These instruments can puncture the inner lining or damage cooling unit e Failure to clean the condenser every three months can cause the unit to malfunction This could void the warranty CAUTION e Using a heater to speed up defrosting can cause per sonal injury and damage to the inner lining DO NOT use any type of heater to defrost e Use only genuine U Line replacement parts Imitation arts can reduce ice rate cause water to overflow from ice maker mold damage the unit and may void the war ranty 044 14 1516 37 9 i 24 61 zj 86 7 2 FULL 4s RETRACT Sr 11 4 HEIGHT 2 WATER OUTLET a WATER DRAIN UL202 Figure 1 UMPON PLEASE READ all instructions completely before attempting to install or operate the unit All Ice Makers require a con nection to the water supply and improper hook up can result in substantial property damage All water and drain
4. connections MUST BE made by a licensed qualified plumb ing contractor Failure to follow recommendations and instructions may result in damage and or harm CAUTION Plumbing installation must observe all state and local codes All water and drain connections MUST BE made by a licensed qualified plumbing contractor Failure to follow recommendations and instructions may result in damage and or harm The CLR2060 can be installed using a gravity drain or can use a fac tory installed or equivalent drain pump 040 Follow these guidelines when installing drain lines to prevent water from flowing back into the ice maker storage bin and or potentially flowing onto the floor causing water damage Gravity Drain e Drain lines must have a 5 8 inside diameter e Drain lines must have a 1 drop per 48 of run 1 4 per foot and must not create traps e The floor drain must be large enough to accommodate drainage from all drains e Insulate the bin drain line to prevent condensation CLR2060 With Factory Installed Drain Pump NOTE Before installing your U Line CLR2060 With Factory Installed Pump it is extremely important to check and test all hose connections at the drain pump There is a possibility that hose connections may have loosened during shipment 1 Make certain the unit is not plugged into an electrical outlet 2 Carefully push the power cord grommet through the hole in the back panel GROMMET UL184 1
5. 1 KU Rp ta ICLEAR HICK MAKER U LINE CORPORATION LIMITED WARRANTY U Line Corporation warrants each U Line product to be free from defects in materials and workmanship for a period of one year from the date of purchase and warrants the sealed system consisting of the compressor the condenser the evaporator the hot gas bypass valve the dryer and the connecting tubing in each U Line product to be free from defects in materials and workmanship for a period of five years from the date of purchase During the initial one year warranty period for all U Line products U Line shall 1 at U Line s option repair any product or replace any part of a product that breaches this warranty and 2 for all Marine RV and Domestic U Line products sold and serviced in the United States including Alaska and Hawaii and Canada U Line shall cover the labor costs incurred in connection with the replacement of any defective part During years two through five of the warranty period for the sealed system U Line shall 1 repair or replace any part of the sealed system that breaches this warranty and 2 for all Marine RV and Domestic U Line products sold and serviced in the United States including Alaska and Hawaii and Canada U Line shall cover the labor costs incurred in connection with the replacement of any defec tive part of the sealed system All other charges including transportation charges for replacements under this warranty and labor c
6. also record the purchase date of your U Line unit and your dealer s name address and telephone number Model Number Serial Number Purchase Date Dealer Name Dealer Address Dealer Telephone Keep this manual and the sales receipt together in a safe place for further reference TABLE OF CONTENTS INTRODUG TON siete acta bate TS 4 SAFETY Fae AMONG sa areni enn ceed i 3 INSTALLATION DIVIENSIONS wr tcccccccveses scakdcvscdsiaereescasiearseaedesaesaeeas 5 DRAIN INSTALLATION as ise se cesta i deena i ce eeveetasiaweeatsesc cd 5 CONNECTING A DRAIN PUMP 8 SIE PREPARATION tss ik aso aso a a rs teas eS 8 CONNECTING THE WATER SUPPLY oaeee 12 LEVELING THE NIT a at narine Beh T ETE T re aa 14 REVERSING THE DOOR smagias sakes esa ais si 15 DOOQR ADJUS IMENI ie ses ss kasis ae aa r Ea Tr NEN 18 CUSTOM DOOR PANELS 2 das asas aisiais Sa alias e eis is 20 BUILT IN INSTALLATION essays a i a eed tal eee ee 22 NITAL DA FED Askas da is sis dis a ak a a i a 23 NORMAL OPEAATION srr e a Ira sa ities aa a os 24 OUTDOOR USE Kk ra eer er eee eee reer eee 27 PUTIN AE aaa ies one tite cette a i eet 28 STORAGE VACATION AND MOVING terete terre neees 34 TROUBLESROQOONNG O eee eer eer eee errr eee 36 IP SERVICE IS ARQUIRE DD E 38 REPLACEMENT PARTS Las as is anl tis eetierest 38 Do not attempt to install or operate your unit until you have read the safety precautions in this manual Safety items throughout this manual are labeled w
7. down the drain UL208 Figure 33 Replace the overflow tube after all of the water has drained from the reservoir 2 Move the cycle selector switch to the CLN position When water begins to flow over the evaporator approx imately 3 minutes add one package of U Line Ice Machine cleaner to the water reservoir Reinstall inside front cover UL209a When the self cleaning Figure 34 process stops approximately 45 minutes it may be desirable to clean the storage bin at this time see INTERIOR CLEANING Move the cycle selector switch to the ICE ON position to resume ice production 040 UM U LINE INLET SCREEN CLEANING EVERY YEAR The solenoid valve inlet screen must be cleaned at least once each year WATER SOLENOID VALVE HOSE CONNECTOR WATER SUPPLY LINE CLRCO013 Figure 35 as follows 1 Shut off the water at the water supply valve 2 Pull the unit out to access the back panel 3 Disconnect electrical power to the unit 4 Disconnect the hose connec tor from the water solenoid valve Figure 35 5 Use a tooth brush to clean sediment from the inlet screen DO NOT remove the screen 6 Reconnect the water supply line to the water solenoid valve Tighten connector securely Open the water supply valve and check for leakage at the water connec tion Make sure the water supply line is not kinked 7 Reconnect power to the unit before re installing 8 Make sure
8. inside unit at upper right hand corner If you do not know the name of the selling dealer or local service company you can check online at www U LineService com for a list of service companies REPLACEMENT PARTS Use only genuine U Line replacement parts Genuine U Line parts are designed to work correctly with U Line products and offer superior service life The use of non U Line parts can damage the unit and may void the warranty UM U LINE Notes Notes 8 2 A P i evi 12 04 i V U LINE CORPORATION P O Box 245040 Milwaukee WI 53224 9540 Phone 414 354 0300 Fax 414 354 7905 www u line com
9. outside dimensions of 8 3 4 wide x 5 3 4 deep x 7 3 4 high e It must have a minimum flow rate of 15 gallons per hour at 10 feet of lift e It must have a sealed sump which does not allow water leakage in the case of a power outage restricted drain or pump failure e It must have a check valve in the discharge line to prevent waste water return to the pump e It must have an overflow protection control which will shut off power to the ice maker in the event of a pump failure e It must have an operating temperature range of 50 F to 110 F 10 C to 40 C MU LINE SITE PREPARATION 1 Position the unit on a flat level surface capable of supporting the entire weight of the unit Remember that the unit will be signifi cantly heavier once it is fully loaded HLL OLR L 2 The surrounding air temperature must be at least 50 F 10 C but must not exceed 110 F 40 C 3 The unit must not be located near heat generating equipment or in direct sunlight 4 The unit must be located to allow clearance for water drain and electrical connections in the rear of the ice maker 5 Connect the unit to its own grounded and polarized 115 VAC 60 Hz 15A circuit normal household current 6 Avoid connecting the unit to a Ground Fault Interruptor GFI GFIs are prone to nuisance tripping which will cause the unit to shut down GFls are generally not used on circuits which power equipment that must run unattended for long
10. periods of time 7 The unit must be installed according to your local codes and ordinances DANGER N ELECTROCUTION HAZARD A Electrical Grounding Reguired This appliance A is eguipped with a three prong grounding polarized plug for your protection against possible shock hazards It must be plugged into a properly grounded three prong receptacle e NEVER remove the round grounding prong from the plug e NEVER use a two prong grounding adapter e NEVER use an extension cord to connect power to the unit Where a two prong wall receptacle is encountered or a longer power cord is required contact a qualified electrician to have it replaced in accordance with applicable electrical codes CLEARANCE NEEDED UL124A Lise 040 Y UO LINE 8 Install and connect the water supply line See CONNECTING THE WATER SUPPLY for installation requirements 9 Position the unit to allow free air flow through the front grille see Figure 3 c Zi a INTAKE EXHAUST UL307A Figure 3 10 Wipe out inside of unit with a damp cloth CONNECTING THE WATER SUPPLY When connecting the water supply follow these guidelines e Review the local plumbing codes before you install the unit e In most instances the cold water supply will come from the basement through a hole in the floor e The water pressure should be between 20 and 120 psi e In
11. product line and performance U Line also backs customers with a strong dealer network U Line s commitment to quality even extends to environmentally safe packaging U Line products are making life more convenient in homes businesses and hotels around the world HWP XOOLRS LI ZAIN Li Once you have your unit installed we suggest you keep this manual in a safe place for future reference Should any problems occur refer to the TROUBLESHOOTING section of this manual This information will help you quickly identify a problem and get it remedied In the event you require assistance please contact the dealer where you purchased your unit PLEASE RECORD YOUR MODELS INFORMATION Whenever you call to request information or service you will need to know your model number and serial number You can find this infor mation on the serial plate located on the inside wall of your unit and on the product registration card PRODUCT REGISTRATION CARD The package containing this manual also includes your product regis tration information Warranty coverage begins at the time your ice maker was purchased NOTE Complete and mail the Product Registration Card as soon as possible to validate the registration date You may also register online at www U LineService com 0404 If you do not return your Product Registration Card U Line will use the date of sale to the U Line distributor as the first date of warranty for your new ice maker Please
12. the drain system is working properly and the drain hose is not pinched or kinked Pour one gallon of cool fresh water into the ice bin The water should drain freely If your CLRCO2075 is equipped with a drain pump the pump should drain the ice bin If the unit is to be stored moved or not used for extended periods it will be necessary to drain the system of water A 0 WP N WARNING Electrical Shock Hazard Disconnect power 9 before servicing Before operating replace all k N panels Failure to do so can result in death or 2 electrical shock Disconnect power from the unit Remove ice from the storage bin Shut off water supply at the main water source Disconnect the inlet and outlet lines to the water valve and allow them to drain N WARNING If the ambient temperature is expected to drop below 45 F drain all water from the unit to prevent freezing damage not covered by the warranty Reconnect inlet and outlet lines to the water valve Replace back panel Drain water from the water trough and drain line by removing the overflow tube see Figure 34 044 Y U LINE 8 Clean the ice maker and storage bin before next use 9 Prop door open to allow for air circulation and prevent mold and mildew HWULPXOLRS LI ZAIN Li User s Manual TROUBLESHOOTING BEFORE CALLING FOR SERVICE If the unit appears to be malfunctioning read through NORMAL OPER ATION first If the problem persists check the
13. TROUBLESHOOTING GUIDE Locate the problem in the guide and refer to the cause and its remedy before calling for service The problem could be something very simple which can be solved without a service call TROUBLESHOOTING GUIDE A AX Troubleshooting What to check when problems occur Possible Cause The unit does No electrical power Make sure power cord not operate to the unit is plugged in Check for blown fuse or tripped circuit breaker Cycle selector switch Make sure cycle selector set improperly switch is set to ICE ON Low air temperature Surrounding air around unit temperature must be at least 45 F 7 C Unit runs but no No water being Check to see that water ice is produced supplied to the unit is connected and turned on to the unit Unit runs but Dirty condenser coils Clean the condenser produces very See MAINTENANCE little ice High air temperature Surrounding air around unit temperature of over 90 F 32 C Low ice production at high temperatures is normal Problem Unit runs but produces very little ice continued Ice is slow to release or does not release from the evaporator Poor ice quality soft or unclear Unit produces shallow or incomplete cubes or the ice fill pattern on the evaporator is incomplete Y UO LINE Possible Cause Scale and mineral buildup in unit Inadequate airflow at the front of the unit Ice making system is dirty
14. aration Document for building and installing a full overlay panel or visit our website at www U line com See Table 1 and Figure 21 for full overlay door panel dimensions Table 1 Full Overlay Panel Dimensions Model A B CLR2060 29 7 8 14 3 4 L B _ gt CUSTOM INSERT DOOR PANEL 4 A custom door panel can be inserted into the door frame to better match the sur rounding decor Custom door panels can be flat or raised as long as the maximum panel thickness where inserted into the door A reveal channel is 1 4 thick For raised panels the depth of the reveal is 1 4 on all four sides See Table 2 and Figure 21 for custom door panel insert dimensions Table 2 Custom Insert Door Panel Dimensions Model A B 2015 Series 28 5 32 141 32 Figure 21 UOLO RUZAN Install the insert as follows Remove top hinge screw pin 7 64 Allen wrench see Figure 22 Remove door by tilting forward and lifting off bottom hinge pin Pull door gasket out of groove top edge of door only Start in the middle and pull outward mov ing toward the edge see Figure 23 This may take some force Do not remove the three screws behind gasket Remove two outside screws hold ing door handle Slightly separate door handle from door Figure 24 Pull handle up and off Remove outer door panel and cardboard spacer Slide custom door panel insert into 1 4 channel in door front Holding door gask
15. dling Frequent cleaning will remove surface contamination that could lead to rust Some installations will require cleaning on a weekly basis DO NOT CLEAN WITH STEEL WOOL PADS DO NOT USE CLEANERS THAT ARE NOT SPECIFICALLY INTENDED FOR STAINLESS STEEL this includes glass tile and counter cleansers If any surface discolors or rusting appears clean it quickly with Bon Ami or Barkeepers Friend Cleanser and a non abrasive cloth Always clean in the direction of the grain Always finish this process with Claire Stainless Steel Polish and Cleaner to prevent further prob lems USE OF ABRASIVE PADS SUCH AS SCOTCHBRITE WILL CAUSE THE GRAINING IN THE STAINLESS TO BECOME BLURRED Rust that is allowed to linger can penetrate into the surface of the stainless steel and become impossible to remove 044 CAUTION Stainless steel models exposed to chlorine gas and mois ture such as areas with spas or swimming pools may have some discoloration of the stainless steel Discoloration from chlorine gas is normal Follow exterior cleaning instructions INTERIOR CLEANING AS REGUIRED sl 2 Disconnect power to the ice maker Open the door and remove any ice from the storage bin Wipe down the interior and storage bin with a solution of non abrasive mild soap or detergent and warm water Rinse with clean water Sanitize the bin with a solution of 1 tablespoon of bleach in 1 gallon of warm water Rinse thoroughly with clean wate
16. e grille screws and tighten being very careful not to overtighten SELF CLEANING CYCLE EVERY 6 MONTHS To maintain operational efficiency clean the unit every six months depending on water conditions more or less frequent cleaning may be necessary If the ice maker requires more frequent cleaning consult a qualified plumber to test the water quality and recommend appropri ate treatment N WARNING CI Wear rubber gloves and safety goggles and or face shield when handling Ice Machine Cleaner CAUTION Use only U Line Ice Machine Cleaner part number 41978 It is a violation of Federal law to use this solution in a man ner inconsistent with its labeling Use of any other cleaner can ruin the finish of the evaporator and will void the war ranty Read and understand all labels printed on the pack age before use U Line ice machine cleaner is used to remove lime scale and other mineral deposits Refer to the following steps to initiate the self cleaning cycle CAUTION Never use anything to force ice from the evaporator Damage may result 040 10 Set the cycle selector switch FRONT COVER to OFF and allow the ice to melt off of the evaporator Remove all ice from the storage bin Remove inside front cover see Figure 33 Remove the overflow tube by lifting it up while using a slight back and forth motion to loosen it from the drain hole see Figure 34 The water in the reservoir will flow
17. e the type up or down of adjust ment needed 2 Remove the top hinge pivot pin with a 7 64 hex arte wrench Figure 18 and lift door off bottom hinge pin f Be careful not to lose door Figure 17 closers Figure 20 3 With door upside down loosen but do not remove the two hinge plate screws UL310 Figure 18 Y U LINE 4 If door edge opposite the hinges needs to move up move plate toward outside of door If door edge needs to move down move plate toward inside of door Figure 19 Repeat until top edge of door is parallel with top of cabinet and tighten screws securely SLOTTED MOUNTING E kis HOLES RAISE LOWER OUTSIDE OUTSIDE DOOR EDGE DOOR EDGE CLRCO001a Figure 19 5 After adjustment is complete remove the door closers from the bottom hinge clean thoroughly and apply petroleum jelly to the mating surfaces of the closers Figure 20 Be sure that bosses on closers align with holes in hinge and hinge plate Mount door and install top hinge pivot pin DOOR CLOSERS ae Figure 20 User s Manual CUSTOM DOOR PANELS Two types of custom door panels can be installed on your U Line unit to harmonize with or accent the surrounding decor FULL OVERLAY DOOR PANEL A full overlay door panel completely covers the door frame and handle to give a built in appearance See your U Line dealer for the optional Full Overlay Door Panel Kit which contains the Panel Prep
18. erformance keep the unit out of direct sunlight e Turn the unit OFF and dispose of any ice cubes if the unit will not be used for 5 days or more Prop door open to allow for air circulation and prevent mold and mildew e If the ambient temperature is expected to drop below 45 F drain all water from the unit to prevent freezing damage not covered by the warranty e High ambient temperatures 110 F or higher may reduce the unit s ice production rate MAINTENANCE Periodic cleaning and proper maintenance will ensure efficiency top performance and long life The maintenance intervals listed are based on normal conditions You may want to shorten the intervals if you have pets the unit is used outdoors or other special considerations EXTERIOR CLEANING AS REQUIRED The door grille and cabinet may be cleaned with a mild detergent and warm water solution Do not use solvent based or abrasive cleaners Use a soft sponge and rinse with clean water Wipe with a soft clean towel to prevent water spotting Stainless Steel Models Stainless steel models may discolor when exposed to chlorine gas pool chemicals salt water or cleaners with bleach Keep your stainless unit looking new by cleaning with a high quality all in one stainless steel cleaner polish on a monthly basis For best results use Claire Stainless Steel Polish and Cleaner which can be purchased from U Line Corporation Part number 173348 7 99 plus shipping and han
19. et out of the way replace handle on door making sure it is seated prop erly on insert and that screw holes line up Install two small removed in step 3 SCrewS Starting at the corners and working inward push door gasket into place on door Place door on bottom hinge pin and install upper hinge screw er S UM U LINE UL310 Figure 22 N DWR020 wo Figure 23 UL132 Figure 24 044 User s Manual BUILT IN INSTALLATION Your U Line product has been designed for either free standing or built in installation When built in your U Line product does not require addi tional air space for top sides or rear However the front grille must NOT be obstructed Table 3 Built in Cabinet Dimensions Unit Dimensions asi Width Height CLR2060 14 15 16 34 1 8 NOTE Reguired for ease of installation removal and door opening you must allow an additional 1 4 to width of unit The unit must be located to allow clearance for water drain and electrical connections in the rear of the ice maker V U LINE INITIAL START UP Once installation and leveling is complete the unit is ready for initial start up and operation Your unit is shipped in the OFF position how ever you may turn it ON OFF using the cycle selector switch located in the grille see Figure 26 CYCLE SELECTOR SWITCH UL316B Figure 26 1 Plug the appliance cord into a 115V polarized and gr
20. factory setting is designed to maintain an ice bridge of approximately 1 16 to 1 8 under normal conditions resulting in a dimple of approximately 1 4 to 1 2 in depth see Figure 28 A fuller cube with less of a dimple results in a thicker ice bridge As the ice bridge becomes thicker the tendency for the cubes to stay together as a slab increases A bridge thicker than 1 8 may cause cubes to over fill the ice bucket BRIDGE BRIDGE 1 4 TO 1 2 1 16 TO 1 8 TOO TN THICK DIMPLE LITTLE OR DIMPLE ICE BRIDGE DIMPLE es ee r GOOD ICE002 Figure 28 Cube Types To adjust 1 Disconnect power to the unit ACCESS PANEL SCREWS Figure 29 044 2 Remove the screws securing the front access panel see Figure 29 DIAL IS FACTORY SET TO 0 ICE CUBE THICKNESS ADJUSTMENT Figure 30 Ice Thickness Adjustment Dial ICE004A 3 Locate the ice cube thickness adjustment dial on the control board see Figure 30 Turn the dial clockwise number to thicken or counterclockwise number to thin the ice bridge HIWUILPXOLRS LI ZANIN Li Y U0 LINE Fas SAMPLE AREA ICE005 Figure 31 Ice Cube Mold 4 Reinstall front access cover 5 Reconnect power to ice maker OUTDOOR USE Some CLR2060 models are designed to operate outdoors Special considerations include the following e For best p
21. ith a Danger Warning or Caution based on the risk type DEFINITIONS This is the safety alert symbol It is used to alert you to potential personal injury hazards Obey all safety messages that follow this symbol to avoid possible injury or death DANGER N DANGER indicates an imminently hazardous situation which if not avoided will result in death or serious injury N WARNING WARNING indicates a potentially hazardous situation which if not avoided could result in death or serious injury N CAUTION CAUTION indicates a potentially hazardous situation which if not avoided may result in minor or moderate injury CAUTION CAUTION used without the safety alert symbol indicates a potentially hazardous situation which if not avoided may result in property damage IMPORTANT Indicates installation operation or mainenance information which is important but not hazard related 0404 GENERAL PRECAUTIONS N DANGER N RISK OF CHILD ENTRAPMENT Before you throw away your old refrigerator or freezer take off the doors and leave shelves in place so that children may not easily climb inside N WARNING e Never attempt to repair or perform maintenance on the unit until the electricity has been disconnected e Altering cutting of power cord removal of power cord removal of power plug or direct wiring can cause serious injury fire and or loss of property and or life and will void the warranty N CAUTION
22. least 1 1 2 clear ance behind the unit for elec trical water supply and drain connections 040 User s Manual LEVELING THE UNIT NOTE It is extremely important that the unit is level If it is not level the ice mold will not fill evenly This can cause a reduc tion in ice rate uneven sized cubes or water spilling into the storage area which will cause the ice in the bin to melt pre maturely Remember that floors near drains have a ten dency to slope towards the drain 1 Use a level to check the levelness of the ice maker from front to back and from side to side see Figure 8 2 If the ice maker is not level adjust the feet on the corners of the unit as necessary see Figure 9 UL314 Figure 8 TURN FOOT TO ADJUST UL205A Figure 9 3 Check the levelness after each adjustment and repeat the previous steps until the unit is level MU LINE REVERSING THE DOOR All U Line units except Stainless Steel models may be left or right hand opening The door opening is easily reversed by moving the hinge hard ware to the opposite side see Figure 10 To reverse the door Ee UL318B Figure 10 1 Remove top hinge screw pin 7 64 Allen wrench from cabinet see Figure 11 Remove door by tilting forward and lifting off bottom hinge pin UL310 Figure 11 2 Remove plastic screw plugs 4 3 each top and bottom from new hinge locati
23. on Do not discard see Figure 12 UL308 Figure 12 3 Remove top hinge 3 screws reinstall hinge screw pin and remount on opposite side BOTTOM see Figure 13 HINGE 5 SCREW PIN L D Figure 13 Remove the two door closer inserts from the existing bottom hinge and install as shown on the new bottom hinge see Figure 14 Figure 14 Remove existing bottom hinge 3 screws and remount on opposite side TOP Remove hinge screw pin With bottom of door facing up remove pivot plate 2 screws flip over and remount on opposite side of door see Figure 15 UM U LINE Figure 15 Holding door upright with top of door tilted forward place hole of door pivot plate on bottom hinge screw pin see Figure 16 Be sure that the bosses on the closers align with holes in hinge and hinge plate Tilt top of door into position in top hinge and install top hinge screw pin Install plastic screw plugs removed in Step 2 in old hinge holes 3 each top and bottom UL319 CLRCO008 Figure 16 DOOR ADJUSTMENT Your door is aligned at the factory before shipment Occasional re adjustment may be necessary especially if an Overlay Panel is installed The following procedure will correct for up to 1 4 alignment UML RAM Li To adjust 1 Compare the top edge of 4 8 the door opposite the hinges to the top edge of a the cabinet and not
24. osts not specifically covered by this warran ty shall be borne by you This warranty is extended only to the original purchaser of the U Line product The Registration Card included with the product should be promptly complet ed by you and mailed back to U Line or you can register on line at www U LineService com The following are excluded from this limited warranty installation charges damages caused by disasters or acts of God such as fire floods wind and lightening damages incurred or resulting from shipping improper installation unauthorized modification or mis use abuse of the product customer education calls food loss spoilage door and water level adjustments except during the first 90 days from the date of purchase defrosting the product adjusting the controls door reversal or cleaning the condenser If a product defect is discovered during the applicable warranty period you must promptly notify either the dealer from whom you purchased the product or U Line at PO Box 23220 Milwaukee Wisconsin 53223 or at 414 354 0300 In no event shall such notification be received later than 30 days after the expiration of the applicable warranty period U Line may require that defective parts be returned at your expense to U Line s factory in Milwaukee Wisconsin for inspection Any action by you for breach of warranty must be commenced within one year after the expiration of the applicable warranty period This limited warrant
25. ounded elec trical outlet 2 Open the water supply valve in the main water source 3 Put the cycle selector switch in the ICE ON position The water fill valve will energize and fill the water reservoir The water fill valve shuts off after 180 seconds The compressor begins to operate and water flows over the evaporator assembly ice cube tray 4 Upon initial start up water flow over the evaporator may be uneven This may cause uneven sized cubes or water spilling into the ice storage bin This is a normal situation and will correct itself within the first twenty four hours of operation After the initial start up period the water will cascade evenly over the evaporator HWP XOLRS LI ZAIN Li User s Manual NORMAL OPERATION The ice maker is designed to make clear ice from most water sources on a consistent basis Water is constantly circulated over the evapo rator assembly As the water freezes gravity causes any sediment to drop into the water trough and not become imbedded in the ice This gives a clearer ice cube with a low mineral content When the ice reaches the desired thickness it falls off the evaporator and into the storage bin The cycle is then repeated When the level of ice reaches the top of the storage bin the unit shuts off As the ice level in the bin drops the unit will automatically restart to keep the bin full Your unit s ice production rate may vary depending on many consider ations Ambient air
26. r Check that all drain connections are in place Reconnect power to the unit N WARNING e DO NOT use solvent cleaning agents or abrasives on the interior These cleansers may transmit taste to the ice cubes or damage or discolor the interior e DO NOT use any cleaner inside the ice maker compart ment other than U Line Ice Machine Cleaner Other cleaners may affect ice quality or damage the unit not covered under warranty See AUTOMATIC CLEAN CYCLE for more information 044 CONDENSER CLEANING EVERY 3 MONTHS To maintain operational efficiency clean the condenser every three months depending on environmental conditions more or less fre quent cleaning may be necessary N WARNING Disconnect electric power to the ice maker e before cleaning the condenser To remove and replace the grille for access to the condenser fins follow this procedure CONDENSER daSATSSN O NTT RS ALLELE a Si Se S Eua Ds k ee UL317A Figure 32 1 Remove the screws at each end of the grille see Figure 32 2 Remove the grille N WARNING DO NOT touch the condenser fins The condenser fins are SHARP and can be easily damaged CAUTION DO NOT use any type of cleaner on the condenser unit 040 3 Clean the condenser coil using a brush or vacuum cleaner Do not touch 4 Position the grille to align the screw holes with the cabinet 5 Insert th
27. stall a SHUT OFF VALVE in the 1 4 supply line not supplied with unit e Connect sufficient tubing to the unit to allow the unit to be moved for cleaning and servicing However make certain that the tubing is not pinched or damaged during installation e U Line recommends the use of copper tubing for installation WATER CONNECTION _ B UL103_CO Figure 4 1 Locate the compression fitting and ferrule packed in the unit Slide the compression fitting and ferrule over the 1 4 water supply line Do not use thread sealing compound or tape Using two wrenches tighten the compression fitting on the supply line see Figure 5 UL134 Figure 5 2 Carefully bend the water sup ply line into position and con nect the line to the solenoid valve see Figure 6 Avoid kinking the water supply line WATER LINE Figure 6 3 For recessed installations allow extra water supply line length to provide slack for easy removal from the recessed area see Figure 7 This will also safeguard against kinking the line Y U LINE Figure 7 NOTE After completing the installation turn on the water and recheck water and drain con nection for leaks Apply additional tightening if needed Do NOT use thread sealing com pound or tape Plug in the power cord Gently push the unit into posi tion If desired the unit may be recessed into cabinet or wall Allow at
28. temperatures water temperatures condenser cleanliness and ice maker cleanliness are all contributing factors to how quickly the unit produces ice Certain sounds are normal during the unit s operation You may hear the compressor or fan motor the water valve the water circulation pump or ice dropping into the ice storage bin ICE CUBE THICKNESS Your U Line Clear Ice Maker uses advanced technology to make ice that is crystal clear This technology cascades a flow of water over a chilled ice mold that is mounted vertically so no water sits in it Because of this ice making technology clear ice cubes differ significantly from reg ular ice cubes Differences are as follows e Dimples U Line clear ice cubes have dimples on one side from the cascading water process e Cube Variations Cubes made from different batches or even cubes within the same batch may have varying dim ples thicknesses and or sizes due to the cascading gt lt water process e Cube slabbing The U Line clear ice maker makes a slab of ice that falls from the verti cal mold relying on gravity to break the ice bridges Depending on the control setting and the fullness of the ice bucket it maybe nec essary to tap the ice slab with the ice scoop to break it apart 044 DIMPLES ICE BRIDGE ICE001 Figure 27 Ice Bridge and Dimples Y UO LINE The ice cube thickness control is factory set for best overall perfor mance The
29. y is in lieu of any other warranty express or implied including but not limited to any implied warranty of merchantability or fitness for a particular purpose provided however that to the extent required by law implied warranties are included but do not extend beyond the duration of the express warranty first set forth above U Line s sole liability and your exclusive remedy under this warranty is set forth in the initial paragraph above U Line shall have no liability whatsoever for any incidental consequential or special damages arising from the sale use or instal lation of the product or from any other cause whatsoever whether based on war ranty express or implied or otherwise based on contract tort or any other theory of liability Some states do not allow limitations on how long an implied warranty lasts or the exclusion or limitation of incidental or consequential damages so the above limitations may not apply to you This warranty gives you specific legal rights and you may also have other rights which vary from state to state DL U LINE INTRODUCTION Congratulations on your purchase of a U Line CLR2060 Ice Maker A pioneer in the field for more than 40 years U Line is the world s num ber one manufacturer of built in under counter ice making and spe cialty refrigeration products U Line dedicates 100 of its research and development to these products The result U Line leads the mar ket with innovation design depth of