Tripp Lite 700 RM UPS Power Supply User Manual
Contents
1. Le brownouts They also protect your equipment against damaging surges o and line noise You can remotely reboot connected equipment by turning all of the receptacles OFF and ON at once using Tripp Lite UPS software See software instructions for details SMART RS 232 Port The RS 232 port connects your UPS to any workstation or server Use with Tripp Lite software and included cable to monitor and manage network power and automatically save open files and shut down equipment during a blackout This port uses RS 232 communications to transmit UPS and power conditions Pin 7 Transmit Pin 8 Common Pin 9 Receive Contact Tripp Lite Customer Support for more information and a list of available SNMP network management and connectivity products Battery Replacement Door Under normal conditions the original batteries in your UPS will last several years z 3 Battery replacement should only be performed by qualified service personnel Refer to Battery Warnings in the Safety section on page 2 When replacing batteries qualified service personnel should follow this procedure 1 turn UPS OFF 2 remove the battery door located on the front panel 3 pull batteries partially out of the case 4 make a detailed sketch of the batteries and the polarity color and connection ofall cables 5 disconnect battery terminals 6 dispose of used batteries 7 reconnect replacement batteries exactly as original batteries were 8 pus
2. a a los recept culos del sistema UPS al modo Standby Reserva y desactivar los recept culos del sistema UPS Interruptor Mute Test Silenciador Autoprueba Utilice este interruptor moment neo para realizar dos funciones A Silenciar la alarma de apagones gt Engrane este interruptor y su ltelo Nota esta alarma sonar y no podr ser silenciada para advertirle que la s bater a s est n casi agotada s y que los equipos conectados deben ser apagados inmediatamente Verificar la carga de las bater as del sistema UPS Mantenga encendidos los equipos conectados Con el sistema UPS encendido ON y conectado a una l nea viva de CA engrane este interruptor sost ngalo por 5 segundos y su ltelo El sistema UPS cambiar moment neamente a bater a para verificar su carga La luz se iluminar y la alarma sonar si el sistema UPS no pasa la prueba y o las bater as no est n totalmente cargadas Permita que el sistema UPS cargue las bater as por 12 horas y repita la autoprueba Si la luz continua encendida comun quese con Tripp Lite para obtener informaci n sobre el centro de servicio m s cercano a usted PRECAUCION No desconecte el sistema UPS para verificar la carga de las bater as Esto eliminar la conexi n a tierra y podr a introducir sobretensiones transitorias perjudiciales a las conexiones de su red Luces Indicadoras Todas las descripciones de la Luces Indicadoras son efectivas mientr
3. d struction Le proc d pour remplacement 1 Arr tez et d branchez l UPS 2 tirez sur la batterie partialement dehors de PUPS 3 dessinez cette batterie et sa polarit son couleur et ses connexions de tous les c blages 4 d branchez la batterie 5 branchez la nouvelle batterie PUPS exactment comme l autre 6 poussez sur la batterie entre l UPS et remplacez le couvercle 7 chargez compl tement la nouvelle batterie ATTENTION Ne pas faire fonctionner cette unit avant d avoir convenablement install et connect les batterie sp cifi es du fabricant Vous r f rez la section Avertissements de la Batterie la page 15 Vous pourriez ne pas obtenir le d lai d ex cution complet jusqu ce que vos batteries de rechange soient enti rement charg es 19 Entreposage et Service Entreposage Positionnez votre syst me d UPS sur OFF engagez tout d abord le Commutateur ON Standby et relachez le afin de placer votre syst me d UPS sur le mode Standby positionnez ensuite le Commutateur du Systeme Enable sur DISABLE d connectez enfin le cordon d alimentation de votre syst me d UPS de la prise murale Si vous envisagez d entreposer votre syst me d UPS pour une longue p riode veuillez recharger les batteries du syst me d UPS une fois tous les trois mois Suivez les tapes 1 et 3 dans la section Installation et laissez le syst me d UPS charger de 4 6 heures Si vous laissez les
4. prong adapters with the UPS s plug e Do not plug your UPS into itself this will damage the UPS and void your warranty e If you are connecting your UPS to a motor powered AC generator the generator must provide clean filtered computer grade output Equipment Connection Warnings e Do not use Tripp Lite UPS Systems for life support applications in which a malfunction or failure of a Tripp Lite UPS System could cause failure or significantly alter the performance of a life support device e Do not connect surge suppressors to the output of your UPS This may damage your UPS and will void both the surge suppressor and UPS warranties pane Warnings e Your UPS does not require routine maintenance Do not open your UPS for any reason There are no user serviceable parts inside e Battery replacement must be performed by qualified service personnel Because the batteries present a risk of electrical shock and burn from high short circuit current observe proper precautions Unplug and turn off the UPS before performing battery replacement Use tools with insulated handles and replace the existing batteries with the same number and type of new batteries Sealed Lead Acid Do not open the batteries Do not short or bridge the battery terminals with any object e The UPS batteries are recyclable Refer to local codes for disposal requirements or in the US only call 1 800 SAV LEAD 1 800 728 5323 for complete recy cling information Do not disp
5. sur la ENABLE partie avant T ENABLE PERMET Ce commutateur active le chargeur de O DISABLE INVALIDE la batterie et le microprocesseur Le voyant va flasher jusqu ce que vous engagiez le Commutateur ON Standby pour activer le mode ON Engagez le commutateur ON Commutateur ON Standby Standby momentan ment panneau situ sur la partie avant avant de l UPS et lib rez le pour lancer le mode ON et fournir l alimentation lectrique aux r ceptacles de l UPS 16 Connexion du Port DB9 a Facultatif 7 age Le Dee A En utilisant le cable Tripp Lite VE UPS SYSTEM OBARCING MAY OCCUR branchez le port DB9 de serveur principal au port unique DB9 DEN cr SMART qui fournit les transmis al a sions completes inteilligentes RS 232 Les connexions du port s rie sont facultatives Votre systeme d UPS fonctionnera correctement sans ces connexions 6 Chargez le logiciel et lancez le programme d installation appropri pour votre syst me d exploitation Op ration de Base Commutateurs Commutateur de System Enable Systeme Valide Ce commutateur lance le chargeur de batterie et le microprocesseur intelligent Laissez le toujours sur la position ENABLE la position de Validation quand votre UPS est branch Placezle Commutateur de Syst me Valide sur DISABLE la position de Hors Fu
6. 7 Entreposage amp Service p 20 Caract ristiques p 20 Copyright 02000 Tripp Lite Tous droits r serv s S ret Ce manuel contient des instructions et recommandations importantes qui doivent tre suivies durant l installation l op ration et entreposage de tous les Syst mes d UPS de Tripp Lite Recommandations relatives a Emplacement du syst me d UPS Installez votre syst me d UPS l int rieur loin de l humidit excessive ou de la chaleur la poussi re ou de la lumi re directe du soleil Pour une meilleure ex cution gardez la temp rature int rieure entre 32 F et 104 F entre 0 et 40 C Laissez un espace ad quat autour de chaque c t du syst me d UPS pour la ventilation appropri e Recommandations relatives la Connexion du syst me d UPS Connectez votre syst me d UPS une prise de terre C A trois fils Ne retirez pas ou ne modifiez pas la broche de terre de la prise du syst me d UPS N utilisez pas d adapteurs deux fourches avec la prise du syst me d UPS Ne branchez pas votre syst me d UPS dans sa propre prise Ceci endommagera le syst me d UPS et mettra fin votre garantie Si vous reliez votre syst me d UPS un g n rateur de Courant Alternatif le g n rateur doit fournir une sortie ordinateur propre et filtr e Recommandations relatives la Connexion du Mat riel N utilisez pas les syst mes d UPS de Tripp Lite pour les applicati
7. Owner s Manual l IBM Network Professional NE 700 RM UPS Customer Support 1 800 420 9764 Rackmount Intelligent Network Hours 8 00am 5 30pm CST Mon Fri UPS System 120V www ReliableUPS com ESPANOL p 7 FRAN AIS p 14 Installation Basic Operation Storage amp Service Specifications Manufactured for distributed through and sold by Tripp Lite official licensee for this product IBM the IBM logo trademark and the IBM trade dress are owned by International Business Machines Corporation and are used under license from IBM IBM does not manufacture this product and provides no warranty or support for this product Please call Tripp Lite Customer Support at 1 800 420 9764 for all questions comments service or support related to this product Copyright 2000 Tripp Lite All rights reserved This manual contains important instructions and warnings that should be followed during the installation operation and storage of all Tripp Lite UPS Systems UPS Location Warnings e Install your UPS indoors away from excess moisture or heat dust or direct sunlight e For best performance keep the indoor temperature between 32 F and 104 F between 0 C and 40 C e Leave adequate space around all sides of the UPS for proper ventilation UPS Connection Warnings e Connect your UPS to a three wire grounded AC power outlet Do not remove or modify the ground pin of the UPS s plug Do not use two
8. adjunte una copia de su factura original Especificaciones T cnicas NP700RM Capacidad de Salida VA Watts 700 450 Tiempo de Operaci n de la Bater a Media Carga Plena Carga Minutos 20 6 Tiempo de Recarga de la Bater a 2 4 hrs Circuito Sugerido 15 amperios Certificaciones UL cUL FCC Class B Voltaje Frecuencia de Entrada 120V 60Hz Rango de Voltaje de Entrada En L nea 87 140 voltios Rango de Voltaje Regulado de Salida 120V 9 Rango de Voltaje de Salida En Bater a 120V 5 Onda de Salida En L nea sinusoidal filtrada Onda de Salida En Bater a sinusoidal modulada en ancho de pulso Supresi n de Sobretensiones de CA excede las normas IEEE 587 Categor as A y B Atenuaci n de Ruidos de CA gt 40 dB Modos de Protecci n de CA Positivo a Neutro Positivo a Tierra Neutro a Tierra Notificaci n de FCC Comit Federal de Comunicaciones sobre Interferencias de Radio Televisi n Nota Este equipo ha pasado todas las pruebas de conformidad con los l mites de dispositivos digitales de la Clase Bde acuerdo con la Parte 15 de la Regulaciones de FCC Comit Federal de Comunicaciones Estos l mites han sido dise ados para proveer protecci n razonable contra interferencias peligrosas en instalaciones dom sticas Este equipo genera utiliza y puede radiar energ a de radio frecuencia y de no ser instalado de acuerdo con las instrucciones suministradas en el manual de operaci n puede causar interfere
9. aquera doucement Plus l UPS corrige la tension plus l indicateur vert s allumera et plus le systeme d onduleur claquera Ces op rations sont normales et automatique et il ne faut rien faire Cet indicateur rouge s allumera si votre syst me d onduleur choue un auto test et la batterie n a pas une charge compl te Laissez le syst me d onduleur charger pendant 12 heures est refaisez l auto test Si l indicateur est cependant allum contactez TOripp Lite pour du service Cet indicateur multi color indique 4 conditions de la charge du systeme d onduleur Il change de vert charge basse ajaune mi charge a rouge charge compl te pendant que vous connectez votre quipement pour vous montrer la charge que l UPS supporte Quand l indicateur est rouge votre UPS supporte une charge plus de 85 de sa capacit Si l indicateur rouge clignote votre UPS est s v rement surcharg D branchez l quipement qui produit la surcharge tout de suite jusque l indicateur ne clignote plus Autres Caract ristiques du Systeme d Onduleur Prises CA a 18 Les prises fournissent votre quipement connect d alimentation de ligne c a pendant l op ration normale elles fournissent votre quipement connect d alimentation par batterie pendant les coupures de courant et les baisses de tension Elles prot gent votre quipement contre les surtensions et les parasites endommageants Vous pouvez relancer de loin l quipement b
10. as el Sistema UPS est conectado a una l nea viva de CA y haya sido encendido ON Esta luz verde se iluminar constantemente para indicar que la energ a de CA est presente en los recept culos o parpadear para indicar que la energ a de CA no est disponible Refi rase a las descripciones del Interruptor System Enable Habilitador del Sistema e Interruptor On Standby Encendido Pausa m s arribal Esta luz multicolor despliega 7 condiciones diferentes acerca de la carga de la bater a del sistema UPS Se iluminar en rojo baja amarillo mediana o verde completa para indicar el nivel de carga de la bater a Si esta luz est constantemente iluminada significa que su sistema UPS est operando con energ a de CA y cargando la bater a Si esta luz parpadea significa que su sistema UPS est operando con energ a de bater a y sta se est desgastando Cuando esta luz est roja y parpadeando cierre todos sus archivos activos y apague su sistema de computaci n Cuando el sistema UPS est regulando autom ticamente el voltaje bajo O alto de entrada esta luz verde se iluminar y el sistema UPS emitir un leve sonido Cuanto m s irregular sea el voltaje de entrada m s se iluminar esta luz verde y m s sonidos emitir r el sistema UPS Estas son condiciones normales y autom ticas del sistema UPS y no requieren ninguna acci n de su parte Esta luz roja se iluminar si el sistema UPS no pasa la au
11. attery Mode PWM sine wave AC Surge Suppression exceeds IEEE 587 Cat A amp B standards AC Noise Attenuation gt 40 dB AC Protection Modes H to N H to G N to G FCC Radio TV Interference Notice Note This equipment has been tested and found to comply with the limits for a Class B digital device pursuantto Part 15 ofthe FCC Rules These limits are designedto provide reasonable protection against harmful interference in a residential installation This equipment generates uses andcanradiate radio frequency energy andifnotinstalled and usedin accordance with the instruction manual may cause interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correctthe interference using one or more of the following measures reorient or relocate the receiving antenna increase the separation between the equipmentand receiver connect the equipmentinto an outlet on acircuit different from that which the receiver is connected consult the dealer or an experienced radio television technician for help The user must use shielded cables and connectors with this product Any changes or modifications to this product not expressly approved by the party responsible for compliance could void the user s authority to op
12. batteries de votre syst me d UPS d charg es pendant une longue p riode elles souffriront d une perte permanente de capacit Service Si vous retournez votre syst me d onduleur a Tripp Lite emballez soigneusement le syst me d onduleur en utilisant le MAT RIEL D EMBALLAGE ORIGINAIRE inclus avec l unit Inclusez une lettre d crivant les symptomes du probl me Si le syst me d onduleur est recu dans le p riode de la garantie de 2 ans inclusez une copie de la facture de vente Caract ristiques NP700RM Tension de Sortie VA Watts 700 425 Temps Secours par Batterie Pleine Charge Mi Charge Min 28 12 Temps de Recharge de la Batterie 2 a 4 heures Circuit Sugg r 15amp res Homologations UL cUL FCC Classe B TOUS LES MODELES Tension Fr quence d Entr e 120V 60 Hz Gamme de Tension d Entr e 87 140 volts Gamme de Tension R gul e de Sortie 120V 9 Gamme de Tension de Sortie Batterie 120V 5 Mode Ligne en Forme d Onde de Sortie vague d onde filtr e Mode Batterie en Forme d Onde de Sortie vague d onde PWM Suppression de Surtensions C A exc de les cat gories A 8 B standard IEEE 587 Attenuation de Bruit C A gt 40 dB Mode de Protection C A H N H G N G Printed on Recycled Paper 93 1 558 200001 1 97 0400
13. dos alambres con el enchufe de este no break e No conecte este no break a s mismo esto causar da os al no break y anular su garant a e Si usted desea conectar este no break a un generador motorizado de energ a de CA dicho generador debe suministrar energ a filtrada y limpia apta para computadoras Advertencias Sobre la Conexi n de Equipos e No utilice no breaks Tripp Lite en aplicaciones para el soporte de la vida humana donde una falla del no break pueda causar anomal as o alterar significativamente el rendimiento del dispositivo de soporte de vida e No conecte supresores de sobretensiones transitorias a los recept culos de salida de este no break Esto puede causar da os al no break y anular las garant as del no break y del supresor de sobretensiones transitorias Advertencias Sobre las Bater as e Este no break no requiere mantenimiento rutinario alguno No abra el no break por ninguna raz n Esta unidad no contiene partes interiores que puedan ser reparadas por el usuario e El reemplazo de las bater as debe ser realizado por personal t cnico capacitado Debido a los riesgos de choques el ctricos y quemaduras causadas por alta corriente de corto circuito interior el personal t cnico capacitado debe observar todas las precauciones pertinentes Desconecte y apague el no break antes de reemplazar las bater as Utilice herramientas con asas aisladas y reemplace las bater as con el mismo n mero y tipo de bater as nue
14. e auto test Sile voyant lumineux continue rester allum contactez Tripp Lite pour le service ATTENTION Ne d branchez pas votre UPS pour tester ses batteries Ceci enl vera la suret de la prise lectrique de terre et peut pr senter une mont e subite pr judiciable dans vos connexions de r seau 17 Indicateurs Lumineux Toutes descriptions sur l indicateur lumineux s appliquent lorsque votre UPS est connect la prise murale et sur la position MARCHE ON a Cet indicateur vert brillera constammant pour indiquer que les prises du syst me d onduleur fournit de l alimentation c a Il clignotera pour indiquer que les prises ne fournit pas de l alimentation c a Voir les d scriptions des l interrupteurs System Enable et On Standby au dessus Cet indicateur multi color repr sente 7 conditions diff rentes de la charge de la batterie de PUPS Il change de rouge charge basse jaune mi charge a vert charge compl te pour indiquer le niveau de la charge de la batterie Si l indicateur est allum constammant PUPS fonctionne de l alimentation c a et la batterie se charge Si l indicateur clignote PUPS fonctionne de l alimentation par batterie et la batterie se d charge Si l indicateur clignote en rouge fermez des fichiers ouverts et arr tez votre ordinateur Quand votre syst me d onduleur correcte la tension haute ou basse cet indicateur vert s allume et le systeme d onduleur cl
15. el cual provee san comunicaciones completas e ee inteligentes tipo RS 232 I T a La conexi n a los puertos seriales es opcional Este sistema UPS funcionar adecuadamente a n sin estas conexiones Instale el software y ejecute el programa de instalaci n de acuerdo con su sistema operativo Operacion Basica Interruptores Interruptor System Enable Habilitador del Sistema Este interruptor activa el cargador de bater as y el microprocesador inteligente Siempre debe estar en la posici n ENABLE Habilitar mientras el sistema UPS est conectado a la l nea de CA Coloque el interruptor System Enable Habilitador del Sistema en la posici n DISABLE Inhabilitar solamente si usted desea almacenar o transportar el sistema UPS esto reduce el desgaste de las bater as Nota La ubicaci n del interruptor System Enable varia de acuerdo almodelo La luz un parpadear hasta que usted coloque el interruptor ON Standby Encendido Reserva en la posici n correcta para activar el modo ON Encendido y suministrar energ a a los recept culos del sistema UPS Interruptor ON Standby Encendido Reserva Este interruptor moment neo controla la energ a al nivel de los O recept culos del sistema UPS Engr nelo moment neamente y su ltelo para pasar alternativamente del modo ON Encendido y suministrar energ
16. ente El puerto inteligente RS 232 conecta su sistema UPS a cualquier estaci n de trabajo o servidor de archivos Utilicelo conjuntamente con el software y cable No 73 0743 de Tripp Lite para monitorear y administrar la energ a de su red salvar autom ticamente sus archivos activos y cerrar su sistema durante un apag n Este puerto utiliza comunicaciones inteligentes tipo RS 232 para la transmisi n de las condiciones de la energ a y del sistema UPS Pin 7 Transmitir Pin 8 Com n Pin 9 Recibir Comun quese con el Departamento de Apoyo a Clientes de Tripp Lite para recibir m s informaci n y obtener una lista de productos disponibles para administraci n de redes conectividad y SNMP Puerta para el Reemplazo de la Bater a 12 Bajo condiciones normales las bater as originales incluidas con este sistema UPS tendr n una vida til de varios a os de duraci n El reemplazo de las bater as solamente debe ser realizado por personal t cnico capacitado Refi rase a la secci n Seguridad Advertencias sobre la Bater a en la p gina 8 El personal capacitado de servicio debe seguir este procedimiento para reemplazar las bater as 1 apague el no break 2 remueva la puerta del compartimiento de bater as ubicado en el panel frontal 3 jale las bater as y col quelas parcialmente fuera del compartimiento 4 haga un diagrama detallado de las bater as y la polaridad color y las conexiones de todos los cables 5 de
17. erate the equipment The policy of Tripp Lite is one of continuous improvement Specifications are subject to change Manual de Operaci n IBM Network Professional 700 RM UPS All Fabricado por Tripp Lite bajo concesi n de licencia otorgada IBM Tripp Lite Oficina Central 1111 W 35th Street Chicago IL 60609 USA Servicios a Clientes 1 800 420 9764 www ReliableUPS com No Break Intel igente para Redes 120V Modelo para Racks o Bastidores INGLES p 1 FRANCES p 14 Seguridad Instalaci n R pida p 9 Operaci n B sica p 10 Almacenaje y Servicio p 13 Especificaciones p 13 Copyright 2000 Propiedad literaria de Tripp Lite Seguridad Este manual contiene advertencias e instrucciones importantes que deben seguirse durante la instalaci n operaci n y almacenaje de todos los no breaks Tripp Lite Advertencias Sobre la Instalaci n de este No break e Instale este no break bajo techo alejado de calor o humedad excesiva polvo o luz solar directa e Para obtener mejores resultados mantenga la temperatura ambiente entre 32 y 104 F entre O y 40 C e Mantenga suficiente espacio alrededor del no break para permitir ventilaci n adecuada Advertencias Sobre la Conexi n de este No break e Conecte este no break a una toma de energ a de CA de tres alambres y con conexi n a tierra No remueva o modifique la clavija de conexi n a tierra del enchufe del no break No utilice adaptadores de
18. h batteries back into case and replace cover You may not receive full runtime until your replacement batteries have fully charged Storage amp Service Storage Turn your UPS OFF first engage the ON Standby Switch and release it to place your UPS in the Standby mode then set the System Enable Switch to DISABLE finally disconnect the UPS power cord from the wall outlet Ifyou plan on storing your UPS for an extended period of time recharge the UPS batteries once every three months Follow steps 1 and 3 in the Installation section and allow the UPS to charge from 4 to 6 hours Ifyou leave your UPS batteries discharged for an extended period of time they will suffer permanent loss of capacity Service Ifreturning your UPS to Tripp Lite please carefully pack the UPS using the ORIGINAL PACKING MATERIAL that came with the unit Enclose a letter describing the symptoms of the problem If the UPS is within the 2 year warranty period enclose a copy of your sales receipt Specifications NP700RM Output Capacity VA Watts 700 450 Battery Runtime Half Load Full Load Min 28 12 Battery Recharge Time 2 4 hrs Suggested Circuit 15 amp Approvals UL cUL FCC Class B Input Voltage Frequency 120V 60 Hz On Line Input Voltage Range 87 140 Volts Voltage Regulated Output Voltage Range 120V 9 On Battery Output Voltage Range 120V 5 Output Waveform Line Mode filtered sinewave Output Waveform B
19. harge If the light is constant then your UPS is operating from line power and the battery is charging If the light is flashing then your UPS is operating from battery power and the battery is discharging When the light flashes red close any files you are working on and shut down your computer Whenever your UPS is automatically correcting high or low AC line voltage this green light will turn ON and the UPS will gently click The more the UPS has to correct voltage the more the green light will turn ON and the more the UPS will click These are both normal automatic operations of your UPS and no action is required on your part This red light will turn ON if your UPS fails a self test and or the UPS battery is less than fully charged Let the UPS charge for 12 hours and perform a second self test If the light continues to stay on contact Tripp Lite for service This multi colored light displays 4 separate UPS load conditions It will turn from green low to yellow medium to red high as you connect equipment to show you the load level your UPS is supporting When the light is red your UPS is supporting a load above 85 of its capacity If the red light begins flashing your UPS is severely overloaded Remove overload immediately until light stops flashing Other UPS Features AC Receptacles The receptacles provide your connected equipment with AC line power during normal operation and battery power during blackouts and
20. lors de la connexion des batteries de remplacement Connectez seulement les cables N gatifs noirs aux terminaux N gatifs noirs Connectez seulement les cables Positifs rouges aux terminaux Positifs rouges Si un technicien qualifi ex cute une permutation chaud lors du remplacement de la batterie lorsque le syst me d UPS et le mat riel connect sont allum s votre syst me d UPS ne pourra pas fournir le secours par batterie en cas d arr t total d alimentation car les batteries seront momentan ment d connect es comme elles sont chang es 15 Instalacion 1 Installez les poign es du rack fournies et montez le systeme d UPS dans un rack de 19 pouces 48 cms en utilisant le materiel du rack standard fourni par l utilisateur Installez votre syst me d UPS dans la position du rack la plus basse possible 2 Branchez votre syst me d UPS dans une prise lectrique Votre syst me d UPS doit occuper un circuit consacr de 15 amp res 3 Branchez votre mat riel votre syst me d UPS Votre syst me d UPS est con u pour supporter du mat riel informatique uniquement La connexion d appareils lectrom nagers d imprimates laser ou de suppresseurs de surtensionn est pas recommand e 4 Allumez votre syst me d UPS Positionnez le Commutateur du Commutateur du Syst me Syst me Enable sur la position Enable Permet situ
21. ly power to the UPS receptacles System Enable Switch Located on Front Panel CT ENABLE 70 DISABLE ON Standby Switch Located on Front Panel DB9 Port Connection Optional ii OT TI UI upc g sean VE UPS SYSTEM 24VDC 75 AMPS MAX Using Tripp Lite cable connect your primary server s DB9 port to the single DB9 port labeled SMART which provides complete intelligent RS 232 communications Serial port connections are optional Your UPS will function properly without these connections Load software and run the installation program appropriate for your operating system Basic Operation Switches System Enable Switch This switch activates the battery charger and intelligent microproces sor Always leave it in the ENABLE position when your UPS is pm plugged in Set the switch to DISABLE only if you store or ship your UPS to reduce battery drain Note The light will flash until you engage the ON Standby Switch to activate the ON mode power ON at the UPS receptacles On Standby Switch This momentary switch controls power to the UPS receptacles O Engage it momentarily and release it to toggle between the ON mode power ON at the UPS receptacles and Standby mode power OFF at the UPS receptacles Mute Test Switch Use this mome
22. ncias alascomunicaciones de radio No obstante no existe garant a alguna de que estas interferencias no ocurrir n en una instalaci n particular Sieste equipo causara interferencias peligrosas en la recepci n de se ales de radio y o televisi n lo cual puede determinarse encendiendo y apagando el equipo se aconseja que el usuario intente corregir la situaci n tomando una o m s de las siguientes medidas reoriente o traslade la antena receptora incremente la distancia entre el equipo y el receptor conecte el equipo a una toma el ctrica o circuito diferente al cual est conectado el receptor solicite la asistencia del distribuidor o de un t cnico de radio y televisi n El usuario debe utilizar cables y conectores blindados con este producto Cualquier cambio o modificaci n a este producto no aprobada porla parte responsable por el cumplimiento de las normas correspondientes podr a anularla autorizaci n o licencia del usuario para opera rel equipo La pol tica de Tripp Lite es una de mejoramiento continuo Las especificaciones est n sujetas a cambios sin previo aviso 13 Manuel de l Utilisateur ll Conception sous Accord de Licence avec IBM Network tn Professional 1111 W 35th Street Chicago IL 60609 USA A 700 RM UPS 1 800 420 9764 www ReliableUPS com Systeme d UPS 120V Montage en Rack a R seau Intelligent ANGLAIS p 1 ESPAGNOL p 7 Surete Installation Rapide p 16 Operation de Base p 1
23. nction seulement si vous entreposez ou exp diez votre UPS pour r duire le drain de batterie Note le voyant lumineux dV flashera jusqu a ce que vous engagiez le commutateur ON Standby pour lancer le mode ON mise sous tension aux r ceptacles de 1 UPS Commutateur ON Standby Marche Attente Ce commutateur momentan contr le la puissance aux r ceptacles de O PUPS Engagez le momentan ment et lib rez le pour permuter entre le mode ON mise sous tension aux r ceptacles de UPS et le mode Standby mise hors tension aux r ceptacles de UPS Commutateur de Mute Test Amortissage Test Utilisez ce commutateur momentan pour faire deux choses Amortissez l alarme d arr t total Engagez ce commutateur et lib rez le Note quand la batterie est presque puis e l alarme reprend et ne peut pas tre amortie pour vous alerter de couper imm diatement l alimentation du mat riel reli 5 Testez la charge de la batterie de l UPS Laissez votre mat riel reli sur ON Avec votre UPS completement branch sur la position ON engagez ce commutateur tenez le la pendant 5 secondes et lib rez le LUPS commutera momentan ment sur la batterie pour tester sa charge Le voyant lumineux s allumera et l alarme peut retentir si votre UPS choue l auto test et ou la batterie de PUPS est moins qu entierement charg e Laissez UPS charger pendant 12 heures et ex cutez un deuxi m
24. ntary switch to do two things dl Silence the blackout alarm Engage this switch and release it Note when the battery is nearly depleted the alarm resumes and cannot be silenced to alert you to immediately shut down connected equipment Test your UPS s battery charge Leave your connected equipment ON With your UPS plugged in and completely turned ON engage this switch hold it there for 5 seconds and release it The UPS will momentarily switch to battery to test its charge The alarm will sound and the light may turn ON if your UPS fails a self test and or the UPS battery is less than fully charged Let the UPS charge for 12 hours and perform a second self test Ifthe light continues to stay on contact Tripp Lite for service CAUTION Do not unplug your UPS to test its batteries This will remove safe electrical grounding and may introduce a damaging surge into your network connections Indicator Lights All Indicator Light descriptions apply when the UPS is plugged into a wall outlet and the System Enable Switch is turned ON This green light will shine constantly to indicate AC power is available VA at the receptacles It will flash to indicate AC power is not available See System Enable Switch and ON Standby Switch descriptions above This multi colored light displays 7 separate UPS battery charge conditions It will turn from red low to yellow medium to green full to show you the level of battery c
25. ons de support vie pour lesquelles un d faut de fonctionnement ou une panne d un syst me d UPS de Tripp Lite pourrait causer la panne ou pourrait modifier de mani re significative l ex cution d un dispositif de support vie Ne connectez pas des suppresseurs de surtension la prise de votre syst me d UPS Ceci endommagera le syst me d UPS et mettra fin aux garanties de votre suppresseur de surtension et de votre syst me d UPS Recommandations relatives la Batterie Votre syst me d UPS n exige pas d entretien courant N ouvrez pas votre syst me d UPS quelqu en soit la raison Il n y a pas de pi ces l int rieur que l utilisateur puisse r parer par lui m me Le remplacement de la batterie doit tre ex cut par du personnel de service qualifi Parce que les batteries pr sentent un risque de choc lectrique et br lent partir du courant lev de court circuit le personnel de service qualifi devra observer des pr cautions appropri es suivantes D branchez et arr tez le syst me d UPS avant d ex cuter le remplacement de batterie Utilisez des outils avec des poign es isolantes et remplacez les batteries existantes par le m me nombre et le m me type de nouvelles batteries acide de plomb scell N ouvrez pas les batteries Nessayez pas d ajouter des batteries externes moins que votre syst me d UPS soit quip de Connecteurs Externes de la Batterie Observez la polarit appropri e
26. ose of the batteries in a fire e Do not attempt to add external batteries unless your UPS is equipped with External Battery Connectors e Observe proper polarity when connecting replacement batteries Only connect Negative black wires to Negative black terminals Only connect Positive red wires to Positive red terminals e If a qualified service representative performs hot swap battery replacement when the UPS and connected equipment are turned ON your UPS will not be able to provide battery backup in the event of a blackout because the batteries will be momentarily disconnected as they are exchanged Installation Install rack handles supplied and mount UPS in standard 19 in rack using standard rack hardware user supplied Install your UPS in the lowest rack position possible Plug your UPS into an electrical outlet Your UPS should occupy a 15 amp dedicated circuit Plug your equipment into your UPS Your UPS is designed to support only computer equipment Connecting household appliances laser printers or surge suppressors is not recommended Turn your UPS ON Set the System Enable Switch to the ENABLE position This switch activates the battery charger and microprocessor The light will flash until you engage the ON Standby Switch to activate the ON mode Engage the momentary ON Standby Switch UPS front panel and release it to activate the ON mode and supp
27. ranch par couper l alimentation des prises du syst me d onduleur et puis la r tablir utilisant le logiciel Tripp Lite Voir les instructions avec le logiciel pour plus d informations Port Intelligent RS 232 Le port RS 232 connecte votre syst me d onduleur n importe station de travail ou serveur Utilisez le avec le logiciel et le cabl ge Tripp Lite pour contr ler l alimentation du r seau pour sauvegarder automatiquement les fichiers ouverts et pour arr ter l quipement en cas d une coupure de courant Ce port utilise les communications RS 232 pour transmettre d informations sur les conditions de l alimentation du syst me d onduleur Broche 7 transmette Broche 8 Commun Broche 9 Re oit Contactez l Assistance Client de Tripp Lite pour plus d informations et une liste des produits disponibles de SNMP gestion de r seau et connectivit Porte Commode du Remplacement de la Batterie Remplacement de la Batterie pour les personnages de service qualifi s Avertissement Le courant haut de court circuit de la batterie pr sent un risque de choc lectrique et de br lure Observez les pr cautions et 1 utilisez des outils insul s Ne courtez pas et ne cr ez pas un pont aux terminales de la batterie Remplacez la batterie avec une batterie du m me type Plomb et Acide Ferm La batterie est recyclable ne l ouvrez pas et ne le d striusez pas en feu Vous r f rez aux codes locaux pour les regulations de
28. sconecte los bornes o terminales de las bater as 6 disponga de las bater as usadas 7 conecte las bater as nuevas exactamente como estaban conectadas las bater as originales 8 coloque las bater as adentro del compartimiento e instale la puerta del mismo Es posible que las bater as nuevas no suministren el tiempo completo de respaldo mientras no est n totalmente cargadas Almacenamiento y Servicio Almacenaje Apague el no break primero mueva el Interruptor ON Standby encendido standby y su ltelo para pasar el modo Standby de operaci n despu s coloque el Interruptor System Enable activar sistema en la posici n DISABLE desactivar finalmente desconecte el cable principal del no break de la toma de energ a el ctrica Si usted desea almacenar el no break por un per odo extendido de tiempo recargue sus bater as una vez cada tres meses Siga los pasos 1 y 3 en la secci n Instalaci n y permita que el no break cargue sus bater as por un per odo de 4 a 6 horas Las bater as que se conserven en estado de desgaste por periodos prolongados de tiempo perder n la capacidad permanente de carga Servicio Si usted necesita enviar el sistema UPS al centro de servicio de Tripp Lite emp quelo cuidadosamente usando el MATERIAL ORIGINAL DE EMPAQUE incluido con la unidad Adjunte una carta describiendo los s ntomas del problema Si la unidad est dentro del periodo de garant a de 2 a os
29. te el no break a una toma de energ a el ctrica Este no break requiere un circuito dedicado de 15 amperios 3 Conecte sus equipos al no break Este no break ha sido dise ado para respaldar nicamente equipos de computaci n No se recomienda la conexi n de electrodom sticos impresoras l ser o supresores de sobretensiones transitorias aeste no break 4 Encienda el sistema UPS Coloque el Interruptor System Enable Interruptor System Enable Habilitador del Sistema en la posici n activar sistema ENABLE Habilitar Ubicado en el Panel Fronte Este interruptor activa el microprocesador y el I ENABLE ACTIVAR cargador de bater as 0 DISABLE La luz ln parpadear hasta que usted PESECTIVAR coloque el interruptor ON Standby Encendido Reserva en la posici n correcta para activar el modo ON Encendido Engrane el interruptor momentaneo F n ON Standby Encendido Reserva en eee ON acon el panel frontal del sistema UPS y encendido standby su ltelo para activar el modo ON Ubicado en el Panel Fronte Encendido y suministrar energ a a los recept culos del sistema UPS Conexion al Puerto DB9 Opcional Usando el cable suministrado por pe SAUTION ponot Tripp Lite conecte el puerto DB9 de VE UPS SYSTEM SABES AMPS MAX su servidor principal de archivos al puerto DB9 rotulado SMART 7 Inteligente
30. toprueba y su bater a no est totalmente cargada Permita que el sistema UPS cargue su bater a por 12 horas y realice una segunda autoprueba Si la luz contin a iluminada comun quese con Tripp Lite para recibir informaci n acerca del centro de servicio m s cercano a usted Esta luz multicolor despliega 4 condiciones diferentes acerca de la carga conectada al sistema UPS Se iluminar en verde baja amarillo mediana o rojo alta a medida que usted conecta sus equipos para indicarle el nivel de carga respaldado por su sistema UPS Cuando la luz est roja indicar que el sistema UPS est respaldando una carga superior al 85 de su capacidad Si la luz roja parpadea significa que el sistema UPS ha sido severamente sobrecargado Desconecte la sobrecarga inmediatamente hasta que la luz deje de parpadear Otras Caracter sticas del Sistema UPS Recept culos de CA Los recept culos suministran a sus equipos conectados energ a de CA durante condiciones normales de operaci n y energ a de bater a durante apagones y caidas de voltaje Tambi n protegen sus equipos contras da os causados por picos o ruidos de l nea Usted puede reiniciar los equipos conectados por control remoto apagando todos los recept culos y encendi ndolos al mismo tiempo por medio del software para sistemas UPS de Tripp Lite Refi rase a las instrucciones que acompa an dicho software para obtener m s informaci n 11 Puerto RS 232 SMART Intelig
31. vas Selladas de Plomo y Acido No abra las bater as No permita que ning n objeto for neo entre en contacto con las terminales o bornes de las bater as e Las bater as utilizadas en conexi n con este no break son reciclables Refi rase a su c digo local para obtener m s informaci n de reciclado o en los Estados Unidos solamente llame al 1 800 SAV LEAD 1 800 728 5323 No utilice fuego para disponer de las bater as e No intente agregar bancos externos de bater as excepto si su no break incluye Conectores para Bancos Externos de Bater as e Observe la polaridad correcta cuando desee reemplazar las bater as Conecte los alambres Negativos negros nicamente a los bornes o terminales Negativas negras Conecte los alambres Positivos rojos nicamente a los bornes o terminales Positivas rojas e Si un representante capacitado de servicio realiza el intercambio instant neo de las bater as mientras el no break y los equipos conectados al mismo est n encendidos su no break no suministrar energ a de respaldo en caso de un apag n ya que las bater as estar n moment neamente desconectadas durante el intercambio Instalaci n 1 Instale las asas para racks o bastidores incluidas y monte el no break en un rack o bastidor est ndar de 19 pulgadas utilizando tornillos para racks o bastidores est ndar suministrados por el usuario Instale este no break en el estante m s bajo del rack 2 Conec