Home

Sound Performance Lab 2710 Stereo System User Manual

image

Contents

1. OO TI Fm h 1 EE CT y I 1 L 1 I I 1 L I CT 3 I CT Cc CT 3 CT 31 I gt E e eS i EE L C B AEE n EG SE A E LE A E A EEE EEE Or EJ 10 Unscrew all 14 Phillips screws which fix the top panel with the Phillips screwdriver and remove the top panel RackPack Step 2 and 3 Fitting Modules Step 2 Rear View Sund For Install and Removal of RackPack Modules Please refer to Manual for details Made in Germany Performance Sp L Laboratory o 8 amp Lo o l o Ta oa D ota NU da NU id NI NW Y bs N NU RackPack E E Model 2710 eg ey www soundperformancelab com Dgo 79 go D 5 CONNECTOR WIRING XLR Pin 1 GND Pin 2 Hot Pin 3 Cold For other connectors please refer to Manual for details Unscrew the two Phillips screws holding the cover panel of slot 3 on the rear Remove the cover panel As long as slot 3 is fitted with a module the cover will not be needed anymore You may want to store it for future use Step 3 Front View MIC GA ly MIC Gary
2. PE Aaa O SU SS ain O p ks VE z O ed A DEF PD E Q Unscrew the two Allen screws socket screws of slot 3 on the front of the RackPack frame with the Allen key and remove the silver decoration panel as well as the blank black panel Keep the decoration panel and handle it with care it is needed for the new module You will not need the black cover anymore as long as slot 3 is fitted with a module You may want to store it for future use RackPack 11 Fitting Modules MODULE 1 MODULE 2 Step 4 and 5 Step 4 Top View 4x Flat ribbon cable with eight plugs to power the modules AWAYS PULL OR PRESS THE PLUGS NEVER THE CABLE silver decoration panel 12 I Insert the new module into the slot from the front side of the RackPack Fix the back of the new module with the four Phillips screws to the rear of the frame two of the Phillips screws needed here came with the new module two further screws remained from unscrewing the rear cover panel see step 2 Now tighten the two M4 socket screws Put them through the holes on the top and bottom of the aluminum panel first then through the top and bottom holes of the front of the module Fix the panel and the front of the module by tightening the M4 screws into the threads of the housing see step 3
3. Sound For Install and Removal of RackPack Modules Please refer to Manual for details erformance spl Laboratory O 8 e gt L D c 9 D C q D o y D D 3 7 D o T D RackPack Model 2710 www soundperformancelab com DO NOT OPEN O an Ce JA GND am GND Let g 7 D 6 2 D 5 2 G3 4 3 D 2 D 1 K SERIAL NUMBER CONNECTOR WIRING XLR Pin 1 GND Pin 2 Hot Pin 3 Cold For other connectors please refer to Manual for details The rear panel GND lift switch eliminates hum by separating the internal ground from the unit s housing ground If hum occurs press the switches to activate GND lift BEFORE switching on the external power supply WARNING TOREDUCE RISK OF FIRE OR ELECTRIC SHOCK DO ECT POWER CORD TO connect the external power supply and the BEFORE REMOVING COVER THIS EQUIPMENT MUST BE EARTHED AUDIO UNIT BEFOR WITCHING ON POWER RackPack with the multi pin power cord fixed to the external power supply NEVER disconnect the external power supply from TTT the RackPack while the power supply is still switched on First switch off the external power supply and wait usero at least one minute before disconnecting RISK OF ELECTRIC SHOCK Am GND LIFT s LEN sorter erin 74 eee Otherwise residual currents can cause serious damages x Q S amp Before you use the RackPack make sure that this voltage selector switch setting reflects S the correct local power line voltage 115V posit
4. einer dette donne i Ne iia 10 Please Note Step 1 oco de roce ea RE Fe RINT reke 10 Step2and3 UT 11 Si puuDnLMECC EUER 12 Link Cable Installation kantret nesa anede i ane taa 13 External Power Supply ii 14 Description Placement Of The External Power Supply On And Off 14 Dimensions and Weight 1 5 recep te cian 15 Guarantee and Product Registration LL 15 RackPack Contents Important Safety Information Please note and retain this information Carefully read and follow all of the safety and oper ating instructions before you use the machine Be doubly careful to follow all warnings and special safety instructions noted in this manual and on the unit This manual provides all information needed to fit or exchange RackPack modules Module manuals do not contain information on fitting and exchanging modules You need this man ual everytime a module is to be fitted or exchanged If the manual is not at hand you can download it like any other SPL product manual at www soundperformancelab com Connections Only use the connections as described Other connections can lead to health risks and equipment damage Water And Humidity Do NOT use this machine anywhere near water for example near a wash basin or bath in a damp cellar near swimming pools or the like In such cases there is an extremely high risk of fatal electrical shocks Insertion Of Foreign Objects Or Fluids
5. Manual RackPack Model 2710 19 3 U mounting frame for SPL RackPack modules Manual RackPack Model 2710 Version 1 0 8 2007 Designer Wolfgang Neumann This user s guide contains a description ofthe product It in no way represents a guarantee of particular characteristics or results of use The information in this document has been care fully compiled and verified and unless otherwise stated or agreed upon correctly describes the product at the time of packaging with this document Sound Performance Lab SPL continuously strives to improve its products and reserves the right to modify the product described in this manual at any time without prior notice This document is the property of SPL and may not be copied or reproduced in any manner in part or fully without prior authorization by SPL SPL electronics GmbH Sohlweg 55 41372 Niederkruechten Germany Tel 49 0 2163 983 40 Fax 49 0 2163 983 420 Email info soundperformancelab com www soundperformancelab com CE Declaration of Conformity Manufacturer SPL electronics GmbH C Type of Equipment Audio Signal Processor Product RackPack Model 2710 Compliance Engineer Wolfgang Neumann Test Basis EN50081 1 1992 EN50082 1 1992 EN6006
6. Step 5 Finally plug the multi pin connector of the ribbon cable that corresponds to the module s slot into the multi pin socket of the new module Make sure that the connection is safe and tight by plugging the connector completely into the socket IMPORTANT Only pull or push the connector never the cable Otherwise you risk damaging the cable Subsequent damages can affect one or more modules RackPack Link Cable Installation Link Cable Installation Top View Flat ribbon cable with two plugs to connect two modules for LINK mode MODULE 1 MODULE 2 MODULE 3 MODULE 4 Flat ribbon cable with eight plugs to power the modules Two modules supporting the LINK feature i e Transient Designer amp DynaMaxx can be run as stereo pairs In LINK mode the master module controls the slave module and allows a coherent processing of stereo programs over both channels Besides coherent stereo oper ations the LINK mode offers further interesting applications please refer to the individual manuals of the modules for further details IMPORTANT You have to specify the master or slave configuration of a module before you fit a module into the RackPack frame The module manuals explain how to configure a module for master or slave mode All modules supporting LINK mode have a 10 pin socket on the top of their circuit board A flat ribbon cable with two 10 pin connectors is part of the module s scope of delivery Plug one of the two
7. NEVER allow a foreign object through any of the machine s chassis openings You can easily come into contact with dangerous voltage or cause a damaging short circuit NEVER allow any fluids to be spilled or sprayed on the machine Such actions can lead to dangerous electrical shocks or fire OPENING THE DEVICE Open the device only to fit or exchange modules The fitting and or exchange of modules should only be carried out by qualified persons In the light of possible physical damage or injuries any manipulation is at your own risk In order to avoid exposure to any residual voltage the device should be disconnected from any power source at least 5 minutes before opening it If you handle the device improperly or ignore the manual part of the delivery of the RackPack frame you risk to damage the device or expose yourself to an electric shock In these cases SPL electronics GmbH denies any responsibility Electrical Power Run this machine ONLY from sources which can provide proper power at the prescribed rating When in doubt about a source contact your dealer or a professional electrician To be sure you have isolated the machine do so by disconnecting the power cord from your wall connection Be sure that the power cord plug is always accessible When not using the machine for a longer period make sure to unplug it from your wall power socket Power Cord Protection Make sure that your power cord is arranged to avoid being stepped on or any k
8. SYMBOL WITHIN A TRIANGLE WARNS YOU ABOUT UNINSULATED HIGH VOLTAGE INSIDE THE TRANSDUCER AND THE POTENTIAL FOR DANGEROUS ELECTRICAL SHOCKS oF CHOC MATTE WHICH CAN ALSO OCCUR EVEN AFTER THE MACHINE HAS BEEN DISCONNECTED FROM A POWER SOURCE Symbols And Notes ALSO IN THIS MANUAL A LIGHTNING SYMBOL WITHIN A TRIANGLE WARNS YOU ABOUT THE POTENTIAL FOR DANGEROUS ELECTRICAL SHOCKS WHICH CAN ALSO OCCUR EVEN AFTER THE MACHINE HAS BEEN DISCONNECTED FROM A POWER SOURCE AN EXCLAMATION MARK WITHIN A TRIANGLE IS INTENDED TO MAKE YOU AWARE OF IMPORTANT OPERATIONAL ADVICE AND OR WARNINGS THAT MUST BE FOLLOWED BE ESPECIALLY ATTENTIVE TO THESE AND ALWAYS FOLLOW THE ADVICE THEY GIVE The symbol of a lamp directs your attention to explanations of important functions or applications pp Attention Do not attempt any alterations to this machine without the approval or supervision of SPL electronics GmbH Doing so could nullify completely any and all of your warranty guarantee rights and claims to user support RackPack 5 Introduction RackPack The RackPack system allows you to set up a very compact customized analog rack on only 3U rack space equipped with both approved and new SPL specialties providing you one of a kind processing highly effective handling and superior audio quality RackPack Modules The Transient Designer opens a new dimension in dynamic processing with its unique level independent signal processing Imitate
9. the front panel if modules are not fit ted already Please note that all modules are shipped without the aluminum front panel You need it when you fit a module into the frame Therefore make sure that you handle the aluminum front panels with the same care and prudence as any other unit surface All screws holding front and rear blind and front panels are needed for the fitting of modules Two additional screws are shipped with every module The external power supply including the cable for connection to RackPack e The AC power cord to feed the IEC spec 3 prong connector e This manual e 4 mm Allen key required for the fitting of the module Please save the original packaging In service cases the original packaging ensures a safe shipping and handling It is also useful for your own transports if you don t use a special housing or rack Placement Place the unit on a level and stable surface The unit s enclosure is EMC safe and effec tively shielded against HF interference Nonetheless you should carefully consider where you place the unit to avoid electrical disturbances It should be positioned so that you can easily reach it but there are other considerations Try not to place it near heat sources or in direct sunlight and avoid exposure to vibrations dust heat cold or moisture It should also be kept away from transformers motors power amplifiers and digital processors Always ensure sufficient air circulation by keeping a d
10. through two resistors Placement Of The External Power Supply Do not place the RackPack on top of the external power supply or the power supply on top of the RackPack Place the external power supply on a level and stable surface only We recom mend a distance of at least 50 cm 20 inches to avoid any interferences between the trans former of the external power supply and the RackPack or other devices Choose a place that is easily accessible so that you can switch off the external power supply quickly in case of an emergency Please mind the notes under Power Connection on page 8 On And Off In switching on and off you do not need to follow any particular sequence with connected devices in the periphery of the RackPack There is however the general rule for a chain of devices in the audio processing to always turn on power amplifiers last and to turn them off first If specified sufficiently you can also switch the external power supply through a multi way connector or other main switches RackPack Dimensions amp Weight Width x Height x Depth 482 x 132 x 296 mm 19 x 5 19 x 11 65 in Weight without modules 5 65 kg 12 46 lbs External Power Supply Dimensions 154 X 67 x236mm 6 06 x 2 63 x 9 29 in External Power Supply Weight 4 25 kg 9 37 lbs Guarantee All SPL products come with a two year manufacturer s guarantee against defects in material or assembly from the date of purchase End users are supported in
11. turn on the RackPack with the POWER switch IMPORTANT Never disconnect the external power supply from the RackPack while the power is switched on Always turn the external power supply off first and then wait approxi mately one minute to allow for any residual current to discharge Now you may disconnect the multi pin connector Mind that residual current can damage the unit if you do not follow this procedure Please read and follow all security advices on pages 4 and 5 Signal Connections Before first connecting any other equipment and in all other cases where you are connect ing cables with or from other sources you should be sure to shut the unit and all machines to be connected off external power supply Otherwise you risk to damage the unit con nected gear or your ears On And Off In switching on and off you do not need to follow any particular sequence with connected devices in the periphery of the RackPack There is however the general rule for a chain of devices in the audio processing to always turn on power amplifiers last and to turn them off first If specified sufficiently you can also switch the external power supply on and off through a multiway connector or other main switches RackPack Rear Panel Connections
12. use a level and stable surface Never place it on a soft surface such as a blanket or a cushion etc If the RackPack is mounted into a rack do not place units below the RackPack that produce excessive heat Power Connection The RackPack is fed through the external power supply Before connecting the power supply always make sure that the position of the voltage selector on the back of the RackPack cor responds to the voltage of your local power supply 115V position 110 120V 230 V position 220 240V In case of doubt please ask your dealer a professional electrician or your local power supplier Before you connect the external power supply to the wall socket please switch its POWER button to OFF Also turn off all devices that you may have already connected to the RackPack If signal or power connections are changed in the future always switch off power before Before you connect the external power supply to the wall socket you should connect it to the RackPack see illustration on page 9 The cable fixed to the external power supply with the multi pin connector on the other end is made to connect to the RackPack It is not possible to connect it incorrectly place the groove at the end of the plug on the spring at the socket on the RackPack and tighten the screw After connecting the external power supply to the RackPack and selecting the correct voltage on the external power supply connect the power supply to the wall socket and then
13. 5 1993 EN61000 3 3 1995 EN60065 2002 EN55013 2001 EN55020 2002 EN61000 3 2 2000 73 23 EWG 93 68 EWG We herewith declare that the construction of the RackPack Model 2710 is in compliance with the standards and regulations mentioned above Notes on environmental protection At the end of its operating life this product must not be disposed of with regular household waste but must be returned to a collection point for the recycling of electrical and electronic equipment The wheelie bin symbol on the product user s manual and packaging indicates that The materials can be re used in accordance with their markings Through re use recycling of raw materials or other forms of recycling of old products you are making an important contribu Er tion to the protection of our environment Your local administrative office can advise you of the responsible waste disposal point WEEE Registration 973349 88 2007 SPL electronics GmbH All rights reserved Names of other companies and their prod ucts are trademarks of their respective owners RackPack Important Safety Information csse HI meme 4 Introductioni siii mE 6 HOOKUP ainia Ad 7 Scope Of Delivery Placement Rack Mounting Placement Of The External Power Supply sees ener enn nnno 7 Air Circulation Power Connection Signal Connections On And Off 8 Rear Panel Connections cesses emen ehem 9 Fitting Modules
14. d especially by several software applications the original Transient Designer remains the state of the art transient modeler The DynaMaxx compressor is incomparably musical and easy to handle Thanks to its signal dependent automation it is the perfect set n forget compressor for demanding studio and live applications Just as efficient and advanced in quality is SPL s DeEsser It has been the first device of its kind to use phase cancellation as a means to reduce sibilants Much more unobtrusive than the common frequency based compression the SPL DeEsser has proven it s technological prominence all over the world Further highlights are the two preamp modules Preference Mic Pre and Premium Mic Pre As an alternative to our tube preamps they are based upon the proven design of our Atmos multi channel recording system The Premium Mic Pre provides the same triple stage design with transformer in and outputs like the Atmos system thus ensures the same reference class results The Preference Mic Pre offers a superior price performance ratio to meet the highest demands in all areas of miking and while a continuous preamp quality is of immea surable value especially with multichannel recordings it is impressively economical as well now with the Preference Mic Pre module Further modules complete the RackPack system that includes the whole range of analogue peripheral equipment and allows for perfect integration into any live and
15. ician when you think repairs are needed or when moisture or foreign objects may accidentally have gotten in to the housing or in cases when the machine may have fallen and shows any sign of having been damaged This also applies to any situation in which the machine has not been subjected to any of these unusual circumstances but still is not functioning normally or its performance is substantially altered In cases of damage to the power cord or its plug first consider turning offthe main circuit breaker before unplugging the power cord Spare Parts Be sure that any service technician uses original spare parts or those with iden tical specifications as the originals Incorrectly substituted parts can lead to fire electrical shock or other dangers including further equipment damage Safety Inspection Be sure always to ask a service technician to conduct a thorough safety check and ensure that the state of the repaired machine is in all respects up to factory standards Cleaning In cleaning do NOT use any solvents as these can damage the chassis finish Use a clean dry cloth if necessary with an acid free cleaning oil Disconnect the machine from your power source before cleaning Warnings DO NOT PLACE THE MACHINE IN SUCH A WAY THAT IT MIGHT COME INTO CONTACT WITH OR SIT ON ANY FLUIDS AVOIDING SUCH CONTACT WILL AVOID HAZARDS FROM FIRE DANGEROUS ELECTRICAL SHOCK OR MACHINE DAMAGE DO NOT OPEN THE MACHINE THE CAUTION LIGHTNING
16. ind of crimping and damage related to such event Do not allow any equipment or furniture to crimp this power cord Power Connection Overloads Avoid any kind of overload in connections to wall sockets extension or splitter power cords Always keep manufacturer warnings and instructions in mind Overloads create fire hazards and risk of dangerous shocks Lightning Before thunderstorms or other severe weather disconnect the machine from wall power but to avoid life threatening lightning strikes not during a storm Similarly before any severe weather disconnect ALL the power connections of other machines and antenna and phone internet cables which may be interconnected so that no lightning damage or over load results from such secondary connections Air Circulation Chassis openings offer ventilation and serve to protect the machine from overheating NEVER cover or otherwise close off these openings NEVER place the machine on a soft surface carpet sofa etc Make sure to provide for a mounting space of 4 5 cm 2 inches when mounting the machine in racks or cabinets Controls and Switches Operate the controls and switches only as described in the manual Incorrect adjustments outside safe parameters can lead to damage and unnecessary repair costs Never use the switches or level controls to effect excessive or extreme changes RackPack Important Safety Information Repairs Unplug the machine and immediately contact a qualified techn
17. ion 110 120V 230 V position 220 240V Qe Fitting Modules Step 1 Please Note Fitting and or exchanging modules should only be done by qualified persons In the light of possible physical damage or injuries any manipulation is at your own risk SPL is not lia ble for any physical damage or injury Before opening the device please read all security advices pages 4 and 5 and the Hook Up information pages 7 and 8 If the device is already in use and you want to expand it with further modules Turn off the external power supply before you open the device and wait at least one minute before you disconnect the device from the external power supply Also disconnect any signal connec tions to other units and wait another five minutes to make sure no residual current is left before opening the RackPack This instruction explains how to fit a module into the third slot In this example modules have already been fitted into slot 1 and 2 You will need the following tools a Phillips screwdriver and a 4 mm Allen key the Allen key is part of the scope of delivery of the RackPack frame Step 1 Top View ill
18. istance of 4 5 cm 2 inches to other units and to the sides of the unit Rack Mounting Be sure that both above and below the machine you maintain a distance of 4 5 cm 2 inches in order to eliminate electromagnetic or high frequency interference from other equipment Moreover this will ensure adequate air circulation to prevent overheating Do NOT locate other machines that produce excessive heat below the unit The rear side of the machine should be properly supported especially when transport is involved Placement Of The External Power Supply Do not place the external power supply on top of the RackPack Place the external power supply on a level and stable surface only We recommend a distance of at least 50 cm 20 inches to avoid any interferences between the external power supply and the RackPack frame or other devices Choose a place that is easily accessible so that you can switch off the external power supply quickly in case of an emergency Please mind the notes under Power Connection and On And Off on the next page RackPack Hook Up Hook Up Air Circulation Always ensure sufficient air circulation in any installation or setup always keep a distance of about 4 5 cm 1 U rack space or about 2 inches to the next device This concerns especially the space above and below the device because louvers are cut into top and bottom panels for optimal heat removal For free placement outside of a rack please always
19. multi pin connectors of the ribbon cable into either one of the multi pin sockets ofthe modules to be connected Make sure that the connections are safe by plugging the connector completely into the socket IMPORTANT Only pull or push the connector never the cable Otherwise you risk to damage the cable Subsequent damages can affect one or more modules RackPack Fitting Modules External Power Supply The external power supply offers fundamental advantages over internal power supplies Properly installed transformer hum and interference should never be an issue and the unit should deliver clean clear audio In addition to that internal circuitry is free from AC power which could negatively influence especially sensitive modules such as preamps The 100 VA transformer is generously proportioned to ensure plenty of power in any situation and proper current for the various circuits Entirely new circuit designs were developed to process the various direct currents The 18V current for example utilizes a discrete voltage regulator with barely measurable noise High speed rectifier diodes and large capacities ensure sufficient current to process even the most powerful impulses In addition most currents are stabilized using 400 V 100 nF MKP foil condensers to ensure plenty of current for fast transients 48V phantom power is also processed using discrete low noise voltage regulators and fed directly to the microphone conductors
20. studio environment From the passive equalizers Bass Ranger and Vox Ranger which are specialized to certain instrument groups through tube effects to monitoring solutions the RackPack system builds a frame to cover the whole set of SPL s expertise in analog signal processing technology Freedom As A Matter Of Principle Whether you need an eight channel preamp an effects rack or individual channel strips The RackPack System offers the maximum freedom to compose customized setups for varying challenges in any live or studio environment Internally we have purposely dispensed with a bus system for connections to and between modules Instead each module provides balanced XLR in and outputs so free routing between modules is ensured Furthermore each module can also be integrated into any stu dio or live environment just like a stand alone device And since two outputs are available simultaneously on each module you can route from any module additionally while it is con nected already to another module or elsewhere If you have for example built a RackPack as a channel strip you can still pick up a signal from any stage Another advantage from the designer s view is that each module can be equipped with I O sockets that perfectly meet the individual module s requirements i e special sockets for monitor modules in stereo or multichannel applications RackPack Scope Of Delivery e The RackPack frame including all blind panels and
21. the two year guarantee through their distributor or dealer In such cases please contact your dealer for full guarantee conditions and service Direct SPL product support requires product registration Please fill out the guarantee card enclosed in the package legibly in printed letters and send it directly to SPL Or use the online registration form that may be reached at www soundperformancelab com international clients or www spl usa com US clients RackPack 15 Manual RackPack Model 2710 spl RackPack

Download Pdf Manuals

image

Related Search

Related Contents

Cobra Radar Detectors User Manual  SCHEDA TECNICA PRODOTTO  SPT SF-3312M Use and Care Manual    Comprendre et Assurer un Service Excellent a ses Clients  La Jeune Garde - Librairie Michèle Noret  njit-etd1999-040 - New Jersey Institute of Technology    投込み式水位計  Marantz SA-11S1 User's Manual  

Copyright © All rights reserved.
Failed to retrieve file