Home
SMC Networks 10/100 Switch User Manual
Contents
1. RJ 45 Connector Pin Assignments Caution DO NOT plug a phone jack connector into any RJ 45 port Use only twisted pair cables with RJ 45 connectors that conform with FCC standards An Ethernet or Fast Ethernet twisted pair link segment requires two pairs of wires Each wire pair is identified by two different colors For example one wire might be green and the other green with a white stripe Each wire pair must be attached to the RJ 45 connector in a specific orientation as detailed below CABLE SPECIFICATIONS RJ 45 Pin Assign RJ 45 Pin Assign ments ments Crossover Straight Through Cable Cable 1 Tx 3 Rx 2 Tx 6 Rx 3 Rx 3 Rx 3 Rx 1 Tx 6 Rx 2 Tx Note The and signs are used to represent the polarity of the wires that make up each wire pair 10 SPECIFICATIONS SPECIFICATIONS EZ Switch 10 100 General Network Interface RJ 45 100 ohm UTP cable 10BASE T Categories 3 4 or 5 100BASE TX Category 5 LEDs Power one Link Activity one per port Filtering Forwarding Learning Rates Full line rate Temperature Operating 32 to 122 F 0 to 50 C Storage 40 to 158 F 40 to 70 C Humidity noncondensing 5 to 95 Standards IEEE 802 3 802 3u ISO IEC 8802 3 11 SPECIFICATIONS EMC Safety Compliances CE Mark Emissions FCC Class B EN 55022 CISPR 22 Class B C Tick AS NZS 3548 1995 Class B EN 61000 3 2
2. SMC Networking Networks EZSwitch 10 100 5 8 Port 10BASE T 100BASE TX Switch e 10 100 Mbps auto negotiation ports e IEEE 802 3 and 802 3u compliance ensures compatibility with standards based hubs switches and cards from any vendor e Auto MDI MDIX on all ports Plug and play nothing to configure e Perfect for small and medium sized wrokgroups e Desktop installation User Guide SMC EZ6505TX SMC EZ6508TX EZ Switch 10 100 User Guide From SMC s EZ line of low cost workgroup LAN solutions SMC Networks 38 Tesla Dec 2002 Irvine CA 92618 Pub 150000021000B RO1 Phone 949 679 8000 Copyright Information furnished by SMC Networks Inc SMC is believed to be accurate and reliable However no responsibility is assumed by SMC for its use nor for any infringements of patents or other rights of third parties which may result from its use No license is granted by implication or otherwise under any patent or patent rights of SMC SMC reserves the right to change specifications at any time without notice Copyright 2002 by 38 Tesla Irvine CA 92618 All rights reserved Printed in China Trademarks SMC is a registered trademark and EZ Hub is a trademark of SMC Networks Inc Other product and company names are trademarks or registered trademarks of their respective holders LIMITED WARRANTY Limited Warranty Limited Warranty Statement SMC Networks Inc SMC
3. 3V m Electrical fast transient burst according to EN 61000 4 4 1995 AC DC power supply 1kV Data Signal lines 0 5kV Surge immunity test according to EN 61000 4 5 1995 AC DC Line to Line 1kV AC DC Line to Earth 2kV gt vi COMPLLANCES Immunity to conducted disturbances Induced by radio frequency fields EN 61000 4 6 1996 0 15 80MHz with 1kHz AM 80 Modulation 3V m Power frequency magnetic field immunity test according to EN 61000 4 8 1993 1A m at frequency 50Hz Voltage dips short interruptions and voltage variations immunity test according to EN 61000 4 11 1994 gt 95 Reduction 10ms 30 Reduction 500ms gt 95 Reduction 5000ms LVD EN60950 A1 1992 A2 1993 A3 1993 A4 1995 A11 1997 Industry Canada Class B This digital apparatus does not exceed the Class B limits for radio noise emissions from digital apparatus as set out in the interference causing equipment standard entitled Digital Apparatus ICES 003 of the Department of Communications Cet appareil num rique respecte les limites de bruits radio lectriques applicables aux appareils num riques de Classe B prescrites dans la norme sur le mat riel brouilleur Appareils Num riques NMB 003 dict e par le minist re des Communications Vil TABLE OF CONTENTS Table of Contents INTRODUCTION use ee ieee ees 1 Descriptionor Hardware ie see seins de Se coe 1 Pe ture sand BCA TCS ns ee 1 Font Panel LEDS
4. TX ports with RJ 45 connectors located on the rear panel of the Switch Each port contains a built in wiring crossover MDI X that allows for the use of straight through twisted pair cable for connections to devices without built in crossover ports 1 e workstations printers etc The DC power receptacle is also located on the rear panel of the hub INSTALLING THE SWITCH INSTALLING THE SWITCH The EZ Switch 10 100 can be placed on a desktop or shelf and stacked with other devices using the provided 4 rubber foot pads Equipment Checklist After unpacking the EZ Switch 10 100 check the contents of the box to be sure you ve received the following components e EZ Switch 10 100 SMC EZ6505TX or SMC EZ6508TX e Appropriate DC power adapter e Four rubber foot pads e SMC Warranty Registration Card e This User Guide Selecting a Site Be sure to follow the site selection guidelines below when choosing a location Select a suitable location for the switch It should be accessible for installing cabling and maintaining the switch The temperature and humidity should be within the ranges listed in the specifications e The status LEDs should be clearly visible INSTALLING THE SWITCH e There should be adequate space approximately two inches on all sides for proper air flow e Make sure twisted pair cable is always routed away from power lines fluorescent lighting fixtures and other sources of electri
5. nia rer a 2 Rear PARCS a ee 3 INSTALLING THE SWITCH 4 Equipment Checklist we ae ie 4 SEICENNE 4 SUS aaa 4 IMSHUCHONSs RENAN ERA AMIE AE 5 SAMPLE APPLICATIONS 6 TROUBLESHOOTING 8 CABLE SPECIFICATIONS 9 Cable Type and Connector ana ar 9 RJ 45 Connector Pin Assignments 9 SPECIFICATIONS 4 4482 ae 11 PZ Swich 10 Wi apta 11 Ss ee M rei aoa 11 Ca DI AA 12 SMC Z 6506 EX ea sd used 13 Vill 1x INTRODUCTION INTRODUCTION This manual describes how to install and use SMC s EZ Switch 10 100 It features 5 8 10 100 Mpbs Auto Negotiation swtich ports and provides the flexibility to fit into your working space with network environment The EZ Switch 10 100 can be used to connect with PCs servers hubs bridges other switches and routers It can also act as a bridge between 10Mbps and 100Mbps networks segments This EZ Switch supports 10Mbps and 100Mbps dedicated bandwidths in each port The Switch is built with plug amp play auto negotiation on all ports store and forward transmission scheme IEEE802 3x flow control and back pressure operation for easy installation and smooth transition from legacy 10Mbps to 100Mbps Ethernet networks All ports support MDI MDI X to facilitate your network expansion Description of Hardware The EZ Switch 10 100 SMC EZ6505TX and SMC EZ6508TX are 5 8 port Fast Ethernet switch featuring 5 8 10BASE T 100BASE TX auto
6. or more of the following measures e Reorient the receiving antenna e Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected e Consult the dealer or an experienced radio TV technician for help EC Conformance Declaration Class B SMC contact for these products in Europe is SMC Networks Europe Edificio Conata II Calle Fructu s Gelabert 6 8 22 44 08970 Sant Joan Despi Barcelona Spain This information technology equipment complies with the requirements of the Council Directive 89 336 EEC on the Approximation of the laws of the Member States relating to Electromagnetic Compatibility and 73 23 EEC for electrical equipment used within certain voltage limits and the Amendment Directive 93 68 EEC For the evaluation of the compliance with these Directives the following standards were applied RFI Limit class B according to EN 55022 1998 cs Limit class A for harmonic current emission according to EN 61000 3 2 1995 Limitation of voltage fluctuation and flicker in low voltage supply system according to EN 61000 3 3 1995 Immunity Product family standard according to EN 55024 1998 Electrostatic Discharge according to EN 61000 4 2 1995 Contact Discharge 4 kV Air Discharge 8 kV Radio frequency electromagnetic field according to EN 61000 4 3 1996 80 1000MHz with 1kHz AM 80 Modulation
7. 3 Immunity IEC 1000 4 2 3 4 6 Safety CSA NRTL C22 2 950 UL 1950 T V GS EN60950 CB IEC60950 Warranty Limited Lifetime SMC EZ6505TX 12 Ports 5 RJ 45 ports Ports 1 5 Twisted pair fixed crossover MAC Address Table 2K entries Memory Buffer 768 K bits per unit Size 5 15 x 3 384 x 1 26 in 13 1 x 8 5 x 3 2 cm Weight 0 794 lbs 0 36 kg Power Requirements DC input 6V 1A Power Consumption 4 6 Watts Heat Dissipation 15 7 BTU hr Maximum Current 0 76A Y 6VDC SPECIFICATIONS SMC EZ6508TX Ports 8 RJ 45 ports Ports 1 8 Twisted pair fixed crossover MAC Address Table 2K entries Memory Buffer 768 K bits per unit Size 6 93 x 3 34 x 1 26 in 17 6 x 8 5 x 3 2 cm Weight 0 794 Ibs 0 36 kg Power Requirements DC input 6V 1A Power Consumption 4 6 Watts Heat Dissipation 15 7 BTU hr Maximum Current 0 76A Y 6VDC 13 SPECIFICATIONS 14 FOR TECHNICAL SUPPORT CALL From U S A and Canada 24 hours a day 7 days a week 800 SMC 4 YOU 949 679 8000 Fax 949 679 1481 From Europe 8 00 AM 5 30 PM UK Time 44 0 118 974 8700 Fax 44 0 118 974 8701 INTERNET E mail addresses techsupport sme com european techsupport smc europe com Driver updates http www smc com index cfm action tech support drivers downloads World Wide Web http www smc com http www smc europe com FOR LITERATURE OR ADVERTISING RESPONSE CALL U S A and Cana
8. ES EXCLUSIVE IF AN SMC PRODUCT DOES NOT OPERATE AS WARRANTED ABOVE CUSTOMER S SOLE REMEDY SHALL BE REPAIR OR REPLACEMENT OF THE PRODUCT IN QUESTION AT SMC S OPTION THE FOREGOING WARRANTIES AND REMEDIES ARE EXCLUSIVE AND ARE IN LIEU OF ALL OTHER WARRANTIES OR CONDITIONS EXPRESS OR IMPLIED EITHER IN FACT OR BY OPERATION OF LAW STATUTORY OR OTHERWISE INCLUDING WARRANTIES OR CONDITIONS OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE SMC NEITHER ASSUMES NOR AUTHORIZES ANY OTHER PERSON TO ASSUME FOR IT ANY OTHER LIABILITY IN CONNECTION WITH THE SALE INSTALLATION MAINTENANCE OR USE OF ITS PRODUCTS SMC SHALL NOT BE LIABLE UNDER THIS WARRANTY IF ITS TESTING AND EXAMINATION DISCLOSE THE ALLEGED DEFECT IN THE PRODUCT DOES NOT EXIST OR WAS CAUSED BY CUSTOMER S OR ANY THIRD PERSON S MISUSE NEGLECT IMPROPER INSTALLATION OR TESTING UNAUTHORIZED ATTEMPTS TO REPAIR OR ANY OTHER CAUSE BEYOND THE RANGE OF THE INTENDED USE OR BY ACCIDENT FIRE LIGHTNING OR OTHER HAZARD LIMITATION OF LIABILITY IN NO EVENT WHETHER BASED IN CONTRACT OR TORT INCLUDING NEGLIGENCE SHALL SMC BE LIABLE FOR INCIDENTAL CONSEQUENTIAL INDIRECT SPECIAL OR PUNITIVE DAMAGES OF ANY KIND OR FOR LOSS OF REVENUE LOSS OF BUSINESS OR OTHER FINANCIAL LOSS ARISING OUT OF OR IN CONNECTION WITH THE SALE INSTALLATION MAINTENANCE USE PERFORMANCE FAILURE OR INTERRUPTION OF ITS PRODUCTS EVEN IF SMC OR ITS AUTHORIZED RESELLER HAS BEEN ADVISED OF THE POSSIBILITY O
9. F SUCH DAMAGES SOME STATES DO NOT ALLOW THE EXCLUSION OF IMPLIED WARRANTIES OR THE LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES FOR CONSUMER PRODUCTS SO THE ABOVE LIMITATIONS AND EXCLUSIONS MAY NOT APPLY TO YOU THIS WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS WHICH MAY VARY FROM STATE TO STATE NOTHING IN THIS WARRANTY SHALL BE TAKEN TO AFFECT YOUR STATUTORY RIGHTS SMC will provide warranty service for one year following discontinuance from the active SMC price list Under the limited lifetime warranty internal and external power supplies fans and cables are covered by a standard one year warranty from date of purchase SMC Networks Inc 38 Tesla Irvine CA 92618 COMPLIANCES FCC Class B This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with instructions may cause harmful interference to radio communications However there is no guarantee that the interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one
10. cal interference such as radios transmitters etc e Make sure that a properly grounded power outlet is within 8 feet 2 44 meters of the hub and is powered from an independent circuit breaker As with any equipment using a filter or surge suppressor is recommended Instructions 1 Positioning the Switch For desktop or shelf mounting attach the four adhesive foot pads to the bottom of the switch 2 Applying Power Plug one end of the power adapter into the socket on the switch s rear panel and the other end into an appropriate electrical outlet Check the Power LED to be sure power is on Note It is not necessary to power off the switch before connecting or disconnecting any UTP cables as these actions ill not disrupt the operation of other devices attached to the switch 3 Connecting PCs Connect each PC to an RJ 45 port on the switch using a straight through twisted pair cable segment maximum 100 meters 328 ft The EZ Switch 10 100 will support up to 5 8 PCs 4 Cascading Switch and Other Network Devices Prepare straight through Category 5 twisted pair cable with RJ 45 plugs Make sure the cable does not exceed 100 meters 328 feet Connect one end of the cable to the switch s port and connect the other end of the calbe to an MDI MDI X RJ 45 port on the other device SAMPLE APPLICATIONS SAMPLE APPLICATIONS Some typical applications for the EZ Hub 10 100 SMC EZ6505TX and SMC EZ6508TX are illustrate
11. d below EZ Switch 10 100 SMC EZ6505TX 3 2 1 6VDC 5 4 yaa Ethernet EZ Switch 10 100 SMC EZ6508TX DINS eee 100 Mbps 100 Mbps Server 10 Mbps Workstations Standalone Switch SAMPLE APPLICATIONS EZ Switch 10 100 SMC EZ6508TX L 100 Mbps Workstations 100 Mbps Servers 100 Mbps Server 10 Mbps Workstations Cascading Switches TROUBLESHOOTING TROUBLESHOOTING 1 Symptom Power LED does not light after power on Probable Causes Power outlet or power cord may be defective Possible Solutions Check for loose connections Check the power outlet by using it for another device Replace the power cord 2 Symptom Link LED does not light after connection is made Probable Causes Swith port network card or cable may be defective Possible Solutions Check that the Switch and attached device are both powered on Be sure the network cable is connected to both devices Verify that Category 5 cable is used for 100 Mbps connections and that the length of any cable does not exceed 100 meters 328 feet Check the network card and cable connections for defects Replace the defective card or cable if necessary CABLE S PECIFICATIONS CABLE SPECIFICATIONS Cable Type and Connector 10BASE T Cable Category 3 4 5 UTP 100 m 328 ft RJ 45 100BASE TX Cable Category 5 UTP 100 m 328 ft RJ 45
12. da Spain UK France Italy Benelux Central Europe Switzerland Nordic Northern Europe Eastern Europe Sub Saharian Africa North Africa Russia PRC Taiwan Asia Pacific Korea Japan Australia India 800 SMC 4 YOU 34 93 477 4935 44 0 118 974 8700 33 0 41 38 32 32 39 02 739 12 33 31 33 455 72 88 49 0 89 92861 0 41 0 1 9409971 46 0 868 70700 44 0 118 974 8700 34 93 477 4920 27 11 314 1133 34 93 477 4920 7 095 290 29 96 86 10 6235 4958 886 2 2659 9669 65 238 6556 82 2 553 0860 81 45 224 2332 61 2 8875 7887 91 22 8204437 Fax 949 679 1481 Fax 34 93 477 3774 Fax 44 0 118 974 8701 Fax 33 0 41 38 01 58 Fax 39 02 739 14 17 Fax 31 33 455 73 30 Fax 49 0 89 92861 230 Fax 41 0 1 9409972 Fax 46 0 887 62 62 Fax 44 0 118 974 8701 Fax 34 93 477 3774 Fax 27 11 314 9133 Fax 34 93 477 3774 Fax 7 095 290 29 96 Fax 86 10 6235 4962 Fax 886 2 2659 9666 Fax 65 238 6466 Fax 82 2 553 7202 Fax 81 45 224 2331 Fax 61 2 8875 7777 Fax 91 22 8204443 If you are looking for further contact information please visit www smc com or www smc europe com Networks 38 Tesla Irvine CA 92618 Phone 949 679 8000 SMC Model Numbers SMC EZ6505TX SMC EZ6508TX Publication Number 150000021000B RO1 Networking SMC Networks 38 Tesla Model Numbers Irvine CA 92618 SMC EZ6505TX SMC EZ6508TX Phone 949 679 8000 Publication N
13. ed products with their respective dates of discontinuance can be found at http www smc com index cfm action customer_service_warranty All products that are replaced become the property of SMC Replacement products may be either new or reconditioned Any replaced or repaired product carries either a 30 day limited warranty or the remainder of the initial warranty whichever is longer SMC is not responsible for any custom software or firmware configuration information or memory data of Customer contained in stored on or integrated with any products returned to SMC pursuant to any warranty Products returned to SMC should have any customer installed accessory or add on components such as expansion modules removed prior to returning the product for replacement SMC is not responsible for these items if they are returned with the product Customers must contact SMC for a Return Material Authorization number prior to returning any product to SMC Proof of purchase may be required Any product returned to SMC without a valid Return Material Authorization RMA number clearly marked on the outside of the package will be returned to customer at customet s expense For warranty claims within North America please call our toll free customer support number at 800 762 4968 Customers are responsible for all shipping charges from their facility to SMC SMC is responsible for return shipping charges from SMC to customer LIMITED WARRANTY WARRANTI
14. negotiation ports These switches provide an ideal bridge between 10 Mbps and 100 Mbps Ethernet networks Features and Benefits e TERE 802 3 and 802 3u compliance ensures compatibility with standards based hubs switches and cards from any vendor 5 8 dual speed 10 100 Mbps auto negotiation ports e Plug and play nothing to configure Built in wiring crossovers on all ports allow INTRODUCTION connections to servers and workstations to be made with straight through cabling e At a glance LEDs for port and system status monitoring e Jabber lock up function automatically stops transmission of abnormal frames to prevent network disruption Automatic polarity detection and correction Desktop installation Front Panel LEDs The front panel of the switch provides status LEDs for at a glance system monitoring The following table details the functions of the various indicators Port and Switch Status LEDs Link Green Indicates a valid network Activity connection between the port and the attached device Off Indicates no network connection established between the port and the attached device Flashing Indicates that the port is Green transmitting or receiving data INTRODUCTION SMC EZ6505TX e EZ Switch 10 100 CRD Link Act SMC EZ6505TX Power 4 2 3 4 5 EZ Switch 10 100 SMC EZ6508TX 7 6 5 4 3 2 1 8 Rear Panel These EZ Switch 10 100 models feature 5 8 10BASE T 100BASE
15. umber 150000021000B R01
16. warrants its products to be free from defects in workmanship and materials under normal use and service for the applicable warranty term All SMC products carry a standard 90 day limited warranty from the date of purchase from SMC or its Authorized Reseller SMC may at its own discretion repair or replace any product not operating as warranted with a similar or functionally equivalent product during the applicable warranty term SMC will endeavor to repair or replace any product returned under warranty within 30 days of receipt of the product The standard limited warranty can be upgraded to a Limited Lifetime warranty by registering new products within 30 days of purchase from SMC or its Authorized Reseller Registration can be accomplished via the enclosed product registration card or online via the SMC web site Failure to register will not affect the standard limited warranty The Limited Lifetime warranty covers a product during the Life of that Product which is defined as the period of time during which the product is an Active SMC product A product is considered to be Active while it is listed on the current SMC price list As new technologies emerge older technologies become obsolete and SMC will at its discretion replace an older product in its product line with one that incorporates these newer technologies At that point the obsolete product is discontinued and is no longer an Active SMC product A list of discontinu
Download Pdf Manuals
Related Search
Related Contents
Interact Service Manual NEC MultiSync FE990 User's Manual User Manual for The West Bengal Post Doctoral Medical Admission REPUBLIQUE DE GUINEE CODE DE L`AVIATION CIVILE REVOIR Manual - Farnell Bass Amplifier - Musik Produktiv SINGLE DISCONNECT BATTERY CONTROL CENTER LA-1000FM Electronic Air Cleaner User Manual Copyright © All rights reserved.
Failed to retrieve file