1. PRECAUCIONES ADVERTENCIA No utilizar en circuitos que excedan el voltaje especificado ya que los voltajes m s altos da ar n el control y pueden causar riesgos de electrocuci n o incendio No cortocircuite las terminales de la v lvula de gas ni del control principal para probarlos Un cortocircuito o una conexi n incorrecta da ar n el termostato y podr an causar lesiones personales y o da os materiales La instalaci n del termostato y de todos los componentes del sistema debe ajustarse alas normas del c digo NEC para los circuitos Clase Il ESPECIFICACIONES APLICACIONES Para utilizar con e Sistemas de calor frio o s lo calor est ndar e Sistemas de calor el ctricos e Sistemas de gas o aceite e Sistemas de gas con dispositivos de encendido intermitente 1 1 D y o amortiguadores de ventilaci n Sistemas hidr nicos agua caliente o vapor Sistemas de bomba de calor de una sola etapa sin calor auxiliar e Sistemas milivoltios NO UTILIZAR CON e Sistemas multietapa e Sistemas que exceden los 30 VCA y 1 5 A e Sistemas de calefacci n hidr nicos zonificados de 3 cables N DE PIEZA 37 6585B Reemplaza 37 6585A 0745 INSTALACION RETIRE EL TERMOSTATO VIEJO 1 Apague la electricidad en la caja de fusibles principal hasta que haya finalizado la instalaci n Aseg rese de que la alimentaci n el ctrica est desconectada 2 Retire la cubierta delantera del termostato viejo Con los cables a
2. 2895 Harrison Street Batesville AR 72501 2117 for proper disposal ELECTRIC HEAT OR SINGLE STAGE HEAT PUMP SYSTEMS This thermostat is configured from the factory to operate a heat cool fossil fuel gas oil etc forced air system It is configured correctly for any system that DOES NOT require the thermostat to energize the fan on a call for heat If your system is an electric heat or heat pump system that REQUIRES the thermostat to turn on the fan on a call for heat locate the GAS ELECTRIC switch on the back of the thermostat see fig 1 and switch it to the ELECTRIC position This will allow the thermostat to ener gize the fan immediately on a call for heat If you are unsure if the heating cooling system requires the thermostat to control the fan contact a qualified heating and air conditioning service person ATTACH THERMOSTAT BASE TO WALL 1 Removethe packing material from the thermostat Gently pull the cover straight offthe base Forcing or prying onthe thermostat will cause damage to the unit If necessary move the electric heat switch see ELECTRIC HEAT SYSTEMS above 2 Connect wires beneath terminal screws on base using appropriate wiring schematic see figs 2 through 7 3 Place base over hole in wall and mark mounting hole locations on wall using base as a template 4 Move base out of the way Drill mounting holes 5 Fasten base loosely to wall as shown in fig 1 using two mounting screws Place a lev
3. n conectados retire la placa de la pared Si el termostato viejo tiene una placa de montaje sobre pared retire el termostato y la placa juntos 3 Identifique cada uno de los cables conectados al termostato viejo usando las etiquetas incluidas con el nuevo termostato 4 Desconecte los cables del termostato viejo de auno ala vez NO DEJE QUE LOS CABLES VUELVANAINTRODUCIRSE EN LA PARED 5 Instale el termostato nuevo siguiendo el procedimiento indicado a continuaci n ATENCI N Este producto no contiene mercurio No obstante puede reemplazar una unidad que s contiene mercurio No abra las celdas de mercurio En el caso de que una celda se da e no toque el mercurio derramado Usando un par de guantes no absorbentes recoja el mercurio derramado con arena u otro material absorbente y vi rtalo en un recipiente que pueda sellarse Si se da a una celda debe desecharse la unidad El mercurio no debe desecharse con los residuos dom sticos Para desechar la unidad que ser reemplazada por este equipo col quela en un recipiente adecuado y env ela a White Rodgers a 2895 Harrison Street Batesville AR 72501 2117 para su eliminaci n adecuada SISTEMAS DE CALOR EL CTRICOS O DE BOMBA DE CALOR DE UNA SOLA ETAPA Este termostato est configurado de f brica para operar un sistema de aire forzado con combustible f sil gas aceite etc de calor frio Est correctamente configurado para cualquier sistema que NO requiera que el
4. newer compressors already have a time delay built in and do not require this feature Your compressor manufacturer can tell you if the feature is already present in their system When the com pressor time delay occurs it will flash the snowflake icon for about five minutes then turn on the compressor 6 Select Temperature Display Adjustment 4 LO to 4 HI Allows you to adjust the room temperature display 4 higher or lower Your thermostat was accurately calibrated at the factory but you have the option to change the display temperature to match your previous thermostat 7 Select Temperature Display F or C Changes the display readout to Celsius or Fahrenheit as required OPERATING FEATURES Now that you are familiar with the thermostat buttons and display read the following information to learn about the many features of the thermostat e SIMULTANEOUS HEATING COOLING SETPOINT STORAGE You can enter both your heating and cooling set points at the same time There is no need to change the thermostat at the beginning of each season e CONFIGURATION MENU Allows you to customize certain thermostat options SETTING THE THERMOSTAT This thermostat is very easy to operate Set the SYSTEM switch to either HEAT or COOL then press O or until the temperature you want to maintain is shown on the right side of the display If you want to turn the system off just move the SYSTEM switch to OFF The FAN switch controls the
5. snaps onto the base The Thermostat Buttons and Switches see fig 8 O Raises temperature setting O Lowers temperature setting 3 FAN switch ON AUTO SYSTEM switch COOL OFF HEAT CONFIGURATION MENU The configuration menu allows you to set certain thermostat operating characteristics to your system or personal require ments Move SYSTEM switch to the OFF position then press O and O at the same time to enter the configuration menu The display will show the first item in the configuration menu The configuration menu chart below summarizes the configura tion options An explanation of each option follows Press O and G to change to the next menu item To exit the menu move the SYSTEM switch to HEAT or COOL If no keys are pressed within fifteen minutes the thermostat will exit the configuration menu Configuration Menu ESB 8 Set SYSTEM switch to HEAT or COOL Press and to advance to next item Press Button s Displayed Factory Default Press or to select COMMENTS SYSTEM switch must be OFF to configure thermostat options Select FA or SL Fast or Slow heating cycle rate d L OFF Select display backlight OFF or ON ON FILTER 0 to 1950 hours Select Filter replacement run time 000 in 50 hour increments LOC ON Select Compressor lockout OFF or ON OFF 4 LO to Select temperature display adjustment higher or lower 0 Select temperature display to F or C Returns to norma
6. termostato energice el ventilador en una llamada de calor Si su sistema es un sistema el ctrico o de bomba de calor que REQUIERE que el termostato encienda el ventilador en una llamada de calor ubique el interruptor GAS ELECTRIC vealafigura 1 y col quelo enla posici n ELECTRIC Esto permitir al termostato energizar el ventilador inmediatamente en una llamada de calor Sino est seguro si el sistema de calefacci n refrigeraci n requiere que el termostato controle el ventilador p ngase en contacto con un servicio t cnico de calefacci n y aire acondicionado calificado FIJE LA BASE DEL TERMOSTATO A LA PARED 1 Retire el material de embalaje del termostato Tire suavemente de la cubierta para separarla de la base Si fuerza o hace palanca sobre el termostato da ar la unidad Si es necesario mueva el interruptor de calor el ctrico vea la secci n SISTEMAS DE CALOR EL CTRICOS m s arriba 2 Conecte los cables que se encuentran debajo de los tornillos terminales a la base consultando el esquema de conexiones apropiado vea las figuras 2 a 7 3 Coloque la base sobre el orificio de la pared y marque las ubicaciones de los orificios de montaje usando la base como plantilla 4 Mueva la base a un lado Perfore los orificios de montaje 5 Fije la base a la pared sin ajustarla demasiado como muestra la figura 1 usando dos tornillos de montaje Coloque un nivel contra la parte inferior de la base aj stela hasta que quede b
7. ADOR Figura 7 Diagrama de conexiones t pico para una bomba Figura 4 Diagrama de conexiones t pico para sistemas Z S f g g pico Pp de calor con v lvula inversora energizada en HEAT de calor fr o de un solo transformador y 4 cables OPERACION Antes de que comience ausar su termostato debe familiarizarse consus funciones y con la pantalla y la ubicaci n y funcionamiento de los diferentes botones Su termostato consta de dos partes la cubierta del termostato y la base Para retirar la cubierta tire suavemente de ella para separarla de la base Para volver a colocarla alinee la cubierta con la base y presione suavemente hasta que se enganche en la base Los botones e interruptores del termostato vea la figura 8 O Sube el ajuste de temperatura O Baja el ajuste de temperatura 8 Interruptor FAN ventilador ON AUTO 2 Interruptor SYSTEM COOL OFF HEAT La pantalla O El icono de la llama 0 aparece cuando el interruptor SYSTEM est en la posici n HEAT El icono del copo de nieve aparece fijo cuando el interruptor SYSTEM est en la posici n COOL El copo de nieve aparece intermitente cuando el termostato est en el modo de bloqueo para evitar que el compresor realice ciclos de encendido y apagado demasiado cortos Muestra la temperatura actual Muestra FILTER cuando el sistema se ha utilizado por la cantidad de tiempo seleccionada en el filtro para recordarle que debe cambiar o limpiar el fi
8. FIGURATION MENU page 4 CHECK THERMOSTAT OPERATION If at any time during testing your system does not operate properly contact a qualified service person Turn on power to the system Fan Operation If your system does not have a G terminal connection skip to Heating System 1 Move FAN switch to ON position The blower should begin to operate 2 Move FAN switch to AUTO position The blower should stop immediately JUMPER WIRE NOTE For 2 wire Heat only Neutral attach to RH and W TRANSFORMER Figure 2 Typical wiring diagram for heat only 3 wire single transformer systems JUMPER WIRE TRANSFORMER Figure 3 Typical wiring diagram for cool only 3 wire single transformer systems RED jumper wire provided with thermostat must be connected between thermostat RH and RC terminals JUMPER for proper thermostat operation with this system Neutral TRANSFORMER Figure 4 Typical wiring diagram for heat cool 4 wire single transformer systems HEATING TRANSFORMER COOLING TRANSFORMER Figure 5 Typical wiring diagram for heat cool 5 wire two transformer systems pressor ntactor CEO E Valve Co Reversing valve is energized when the system switch is in the COOL position JUMPER JUMPER WIRE WIRE TRANSFORMER Figure 6 Typical wiring diagram for heat pump with reversing valve energized in COOL JUMPER JUMPER WIRE WIRE Reversing valve is energized when the Neutral sys
9. White y Rodgers 1F86 344 Non Programmable Electronic Digital Thermostat INSTALLATION AND OPERATION INSTRUCTIONS Operator Save these instructions for future use FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE PERSONAL INJURY AND OR PROPERTY DAMAGE Your new White Rodgers Digital Thermostat uses the technol ogy of a solid state microcomputer to provide precise tempera ture control Features e Simultaneous heat and cool setpoint storage e Pre set temperature control e Backlit display e LCD continuously displays setpoint and room temperature This thermostat is intended for use with a low voltage system do not use this thermostat with a line voltage system If in doubt about whether your wiring is millivolt line or low voltage have it inspected by a qualified heating and air conditioning contrac tor or electrician Do not exceed the specification ratings All wiring must conform to local and national electrical codes and ordinances This control is a precision instrument and should be handled carefully Rough handling or distorting components could cause the control to malfunction To prevent electrical shock and or equipment damage disconnect electric power to system at main fuse or circuit breaker box until installation is complete ELECTRICAL DATA Electrical Rating 8 to 30 VAC 50 60 Hz or D C 0 05 to 1 0 Amps Load per termin
10. ace of pur chase HOMEOWNER HELP LINE 1 800 284 2925 White y Rodgers The Emerson logo is a St Louis Missouri Markham Ontario trademark and service mark f of Emerson Electric Co www white rodgers com White y Rodgers 1F86 344 Termostato digital electr nico no programable INSTRUCCIONES DE INSTALACI N Y OPERACION Sr operador Conserve estas instrucciones para consultarlas en cualquier momento EL NO LEER Y SEGUIR CON CUIDADO TODAS LAS INSTRUCCIONES ANTES DE INSTALAR O UTILIZAR ESTE CONTROL PODRIA CAUSAR LESIONES PERSONALES Y O DANOS MATERIALES Su nuevo termostato digital de White Rodgers utiliza la tecnolog a de una microcomputadora de estado s lido para proporcionar un control preciso de la temperatura Caracter sticas e Almacenamientosimult neodetemperaturadereferenciade calefacci n y refrigeraci n e Control de temperatura pre definida e Pantalla con luz de fondo e La pantalla de LCD muestra de forma permanente la temperatura de referencia y la temperatura ambiente Este termostato est dise ado para ser utilizado con un sistema de bajo voltaje no utilice este termostato con un sistema de voltaje de l nea Si tiene dudas acerca de si su conexi n el ctrica es milivoltio de l nea o de bajo voltaje h gala inspeccionar por un t cnico especializado en equipos de calefacci n y aire acondicionado o por un electricista autorizado No exceda los valores nominales especificados Todas las c
11. age heat pump systems no auxiliary heat e Millivolt systems DO NOT USE WITH e Multi stage systems e Systems exceeding 30 VAC and 1 5 amps e 3 wire zoned hydronic heating systems PART NO 37 6585B Replaces 37 6585A 0745 INSTALLATION REMOVE OLD THERMOSTAT 1 Shut off electricity at the main fuse box until installation is complete Ensure that electrical power is disconnected 2 Remove the front cover of the old thermostat With wires still attached remove wall plate from the wall If the old thermostat has a wall mounting plate remove the thermostat and the wall mounting plate as an assembly 3 Identify each wire attached to the old thermostat using the labels enclosed with the new thermostat 4 Disconnect the wires from old thermostat one at a time DO NOT LET WIRES FALL BACK INTO THE WALL 5 Install new thermostat using the following procedures ATTENTION This product does not contain mercury However this product may replace a unit which contains mercury Do not open mercury cells If a cell becomes damaged do not touch any spilled mercury Wearing nonabsorbent gloves take up the spilled mercury with sand or other absorbent material and place into a container which can be sealed If a cell becomes damaged the unit should be discarded Mercury must not be discarded in household trash When the unit this product is replacing is to be discarded place in a suitable container and return to White Rodgers at
12. al 1 5 Amps Maximum Total Load All terminals combined THERMAL DATA Setpoint Temperature Range 45 F to 90 F 7 C to 32 C Operating Ambient Temperature Range 32 F to 105 F Operating Humidity Range 0 to 90 RH non condensing Shipping Temperature Range 4 F to 150 F amp White Rodgers is a division of Emerson Electric Co www white rodgers com EMERSON Climate Technologies DESCRIPTION e F C convertibility e Temperature range 45 to 90 F e RC RH C W Y G O and B terminals e Optional C terminal Dual Power option e Band O terminals for single stage heat pumps no auxiliary heat or damper operation e Setpoint storage in case of power loss e 2 AA alkaline batteries included PRECAUTIONS A WARNING Do not use on circuits exceeding specified voltage Higher voltage will damage control and could cause shock or fire hazard Do not short out terminals on gas valve or primary control to test Short or incorrect wiring will damage thermostat and could cause personal injury and or property damage Thermostat installation and all components of the sys tem shall conform to Class II circuits per the NEC code SPECIFICATIONS APPLICATIONS For use with e Standard heat cool or heat only systems e Electric heat systems e Gas or oil fired systems e Gas systems with intermittent ignition devices I 1 D and or vent dampers e Hydronic hot water or steam systems e Single st
13. calefacci n de aire forzado Sitiene un sistema de calefacci n hidr nico un sistema que genera calor con agua caliente o vapor debe configurar el termostato para que funcione de manera adecuada con su sistema Cambie la segunda opci n en el men de configuraci n a SL vea el MENU DE CONFIGURACION en la p gina 4 VERIFIQUE EL FUNCIONAMIENTO DEL TERMOSTATO Si en alg n momento durante la prueba su sistema no funciona correctamente p ngase en contacto con un servicio t cnico calificado Encienda la alimentaci n del sistema Funcionamiento del ventilador Si su sistema no tiene una conexi n terminal G pase directamente a la secci n Sistema de calefacci n 1 Mueva el interruptor FAN a la posici n ON El soplador deber a comenzar a funcionar 2 Mueva el interruptor FAN a la posici n AUTO El soplador deber a detenerse inmediatamente CABLE DE PUENTE TRANSFORMADOR DE CALEFACCION Para s lo calor con 2 cables Neutro conectara RH y W TRANSFORMADOR no Neutro Figura 2 Diagrama de conexiones t pico para sistemas de solo calor de un solo transformador y 3 cables TRANSFORMADOR DE REFRIGERACI N Figura 5 Diagrama de conexiones t pico para sistemas de calor frio de dos transformadores y 5 cables El cable de puente ROJO suministrado con el termostato debe conectarse entre las terminales RH y RC del termostato para que funcione en forma adecuada con este sistema Neutro TRANSFORMADOR TRANSFORM
14. el against bottom of base adjust until level and then tighten screws Leveling is for appearance only and will not affect thermostat operation If you are using existing mounting holes or if holes drilled are too large and do not allow you to tighten base snugly use plastic screw anchors to secure subbase Screw anchors Y Y Y Y de Y e Y Y Y Y Y Y Y O Mounting holes Electric Gas switch 6 Push excess wire into wall and plug hole with a fire resistant material such as fiberglass insulation to prevent drafts from affecting thermostat operation BATTERY LOCATION 2 AA alkaline batteries are included in the thermostat at the factory with a battery tag to prevent power drainage You must remove the battery tag to engage the batteries If LO BATTERY is displayed the batteries are low and should be replaced For best results replace all batteries with new premium brand alkaline batteries such as Duracell or Energizer To replace batteries install the batteries along the top of the base see Fig 1 The batteries must be installed with the positive end to the left HYDRONIC HOT WATER OR STEAM HEATING SYSTEMS This thermostat is set to operate properly with a forced air heating system If you have a hydronic heating system a system that heats with hot water or steam you must set the thermostat to operate properly with your system Change the second option in the configuration menu to SL see CON
15. endr encendida durante un breve tiempo despu s de presionar cualquier bot n Si selecciona OFF la luz se mantendr apagada Seleccione filter replacement run time tiempo de ejecuci n de reemplazo de filtro El termostato mostrar FILTER despu s del tiempo de funcionamiento seleccionado El prop sito de este mensaje es recordarle que cambie o limpie el filtro de aire El tiempo puede ajustarse desde O hasta 1950 horas en incrementos de 50 horas Si elige 000 se cancelar esta funci n Cuando aparece FILTER puede borrarlo presionando O y O al mismo tiempo De esta manera volver a cero el reloj y se comenzar n a contar las horas que faltan hasta el siguiente cambio de filtro Seleccione Compressor Lockout bloqueo del compresor LOC OFF desactivado u ON activado Si selecciona LOC ON el termostato esperar 5 minutos para encender el compresor si el sistema de calefacci n y refrigeraci n deja de recibir alimentaci n el ctrica Tambi n esperar 5 minutos como m nimo entre ciclos de refrigeraci n para evitar que el compresor realice ciclos de encendido y apagado cortos Algunos compresores m s nuevos ya LINEA DE AYUDA PARA EL USUARIO 1 800 284 2925 White y Rodgers St Louis Missouri Markham Ontario El logotipo de Emerson es una marca comercial y una marca de servicio de Emerson Electric Co www white rodgers com
16. fan operation When the FAN switch is set to AUTO the fan will cycle with the furnace or air conditioner When the FAN switch is set to ON the fan will run continuously regardless of SYSTEM switch position TROUBLESHOOTING No Heating With the SYSTEM switch set to HEAT when the setpoint temperature is raised or lowered past the room temperature the thermostat will make a soft click sound Usually the sound indicates the thermostat is operating correctly If the system does not come on check the system or contact your heating cooling service person If the thermostat does not click try the Reset Operation listed below No Cooling Same procedure as heating except set SYSTEM switch to COOL There can be up to a 5 minute compressor lock out time delay before the thermostat clicks in COOL Blank Display A blank digital display usually indicates the thermostat has received a voltage spike static discharge or requires new batteries If the display remains blank after replacing the batteries see Reset Operation below Reset Operation If a voltage spike or static discharge blanks out the display or causes erratic thermostat operation you can reset the thermo stat by pressing O O and move the SYSTEM switch from OFF to HEAT at the same time This also resets the factory defaults to the configuration menu If the thermostat has power has been reset and still does not function correctly contact your heating cooling service person or pl
17. figuraciones producen un control de temperatura sumamente exacto y pueden ajustarse seg n su preferencia personal La configuraci n FA apaga y enciende el sistema debajo de 1 F y la configuraci n SL lo hace a aproximadamente 1 5 F Men de configuraci n Presione el bot n La pantalla muestra o botones ajustado de f brica Ajuste el interruptor SYSTEM en OFF Presione O 01 para seleccionar OBSERVACIONES El interruptor SYSTEM debe estar en OFF para configurar las opciones del termostato SUS FA SL Selecciona FA o SL r pida o lenta para la velocidad del ciclo de calefacci n d L OO ON OFF Selecciona luz de fondo de pantalla OFF apagada u ON encendida FILTER OIO 000 OIO O a 1950 horas en incrementos de 50 horas Selecciona el tiempo de ejecuci n de reemplazo del filtro Selecciona el bloqueo del compresor en OFF desactivado u ON activado Selecciona el ajuste de la temperatura visualizada m s arriba o m s abajo OO Selecciona la visualizaci n de la temperatura en F o C Ajuste el interruptor SYSTEM en HEAT o COOL Presione G y para pasar a la siguiente opci n del men Vuelve al funcionamiento normal 2 3 4 Seleccione Display Backlight luz de fondo de pantalla d L OFF desactivada u ON activada La luz de fondo mejora el contraste de la pantalla en condiciones de poca luz Si selecciona backlight ON la luz se mant
18. ien nivelada y luego apriete los tornillos Esto es por razones est ticas solamente y no afectar el funcionamiento del termostato Si utiliza los orificios de montaje existentes o si los orificios perforados son demasiado grandes y no le permiten ajustar bien la base use anclajes pl sticos para fijar la subbase Anclajes pl sticos Orificios ifici Orificios de montaje de montaje Interruptor el ctrico de gas Figura 1 Base del termostato 6 Empuje el cable que sobresale hacia el interior de la pared y tape el orificio con un material ignifugo como aislamiento de fibra de vidrio para evitar que las corrientes de aire afecten el funcionamiento del termostato UBICACI N DE LAS PILAS El termostato viene de f brica con 2 pilas alcalinas AA unidas entre s para evitar que se descarguen Debe retirar la tira de papel para poder enganchar las pilas en su lugar Si aparece el mensaje LO BATTERY significa que las pilas tienen poca carga y deben cambiarse Para obtener resultados ptimos cambie todas las pilas por pilas alcalinas nuevas de alguna marca l der como Duracell o Energizer Para cambiar las pilas inst lelas a lo largo de la parte superior de la base vea la figura 1 Las pilas deben instalarse con los polos positivos hacia la izquierda SISTEMAS DE CALEFACCI N HIDR NICOS AGUA CALIENTE O VAPOR Este termostato est configurado para funcionar en forma adecuada con un sistema de
19. l operation 2 Select FA or SL Fast or Slow Heating Cycle Rate The FA setting is frequently used for gas oil or electric heat The SL setting produces a longer heating cycle which is nor mally for hot water or steam hydronic systems Both settings produce very accurate temperature control and can be set to your personal preference FA cycles the system just under 1 F and the SL setting cycles at approxi mately 1 5 F 3 Select Display Backlight d L OFF or ON The display backlight improves display contrast in low lighting condi tions Selecting backlight ON will keep the light on for a short period of time after any key is pressed Selecting OFF will keep the light off 4 Select filter replacement run time The thermostat will display FILTER after the selected time of operation This is a reminder to change or clean your air filter This time can be set from 0 to 1950 hours in 50 hour increments A selection of 000 will cancel this feature When FILTER is displayed you can clear it by pressing gt and O at the same time This resets the timer and starts counting the hours until the next filter change 5 Select Compressor Lockout LOC OFF or ON Select ing LOC ON will cause the thermostat to wait 5 minutes before turning on the compressor ifthe heating and cooling system loses power It will also wait 5 minutes minimum between cooling cycles This is intended to help protect the compressor from short cycling Some
20. ltro de aire Muestra la temperatura de referencia aparece en blanco cuando el interruptor SYSTEM est en la posici n OFF O Muestra BATTERY y LO en lugar de la temperatura cuando las 2 pilas AA tienen poca carga y deben cambiarse MEN DE CONFIGURACI N El men de configuraci n le permite ajustar ciertas caracter sticas operativas del termostato seg n el sistema o sus necesidades particulares Mueva el interruptor SYSTEM a la posici n OFF y luego presione O y O al mismo tiempo para ingresar en el men IA c El Li Figura 8 Pantalla botones e interruptores del termostato de configuraci n La pantalla mostrar la primera opci n del men de configuraci n En el cuadro del men de configuraci n a continuaci n se resumen las diferentes opciones de configuraci n disponibles seguidas por una explicaci n de cada una Presione O y O para pasar a la siguiente opci n del men Para salir del men mueva el interruptor SYSTEM a HEAT o COOL Si pasan quince minutos sin presionar ning n bot n el termostato saldr del men de configuraci n 1 Seleccione FA o SL r pida o lenta para Heating Cycle Rate velocidad del ciclo de calefacci n La configuraci n FA suele utilizarse para sistemas de calefacci n de gas aceite o el ctricos La configuraci n SL produce un ciclo de calefacci n m s largo que lo normal para sistemas de agua caliente o vapor hidr nicos Ambas con
21. onexiones el ctricas deben cumplir con los c digos y reglamentaciones locales y nacionales Este control es un instrumento de precisi n y debe manipularse con cuidado La manipulaci n descuidada o la distorsi n delos componentes podr an hacer que el control no funcionara correctamente PRECAUCI N Para evitar descargas el ctricas y o da os al equipo desconecte la alimentaci n el ctrica en la caja de fusibles o disyuntores principal hasta que haya finalizado la instalaci n del sistema DATOS EL CTRICOS Caracter sticas el ctricas 8 a30 VCA 50 60 Hz o CC 0 05 a 1 0 A carga por terminal 1 5 A de carga total m xima todas las terminales combinadas DATOS T RMICOS Rango de temperatura de referencia 45 F a 90 F 7 C a 32 C Rango de temperatura ambiente operativa 32 F a 105 F Rango de humedad operativa 0 a 90 HR sin condensaci n Rango de temperatura de transporte 4 F a 150 F M iy EMERSON White Rodgers es una divisi n de Emerson Electric Co www white rodgers com DESCRIPCION e Convertibilidad de F a C e Rango de temperatura de 45 a 90 F e Terminales RC RH C W Y G OyB e Terminal C opcional opci n de doble alimentaci n e Terminales B y O para bombas de calor de una sola etapa sin calor auxiliar u operaci n de amortiguaci n e Almacenamiento de temperatura de referencia en caso de cortes de energ a el ctrica e Incluye 2 pilas alcalinas AA
22. tem switch is in the HEAT position TRANSFORMER Figure 7 Typical wiring diagram for heat pump with reversing valve energized in HEAT The 24 Volt neutral connection to terminal C on the thermostat is not required if the batteries are replaced once a year with fresh premium brand alkaline batteries Heating System Move SYSTEM switch to HEAT position Ifthe heating system has a standing pilot be sure to light it 2 Press O to adjust thermostat setting above room tempera ture The heating system should begin to operate 3 Press to adjust temperature setting below room tem perature The heating system should stop operating Cooling System To prevent compressor and or property damage if the outdoor temperature is below 50 F DO NOT operate the cooling system Move SYSTEM switch to COOL position Press to adjust thermostat setting below room tempera ture The blower should come on immediately on high speed followed by cold air circulation Press to adjust temperature setting above room tem perature The cooling system should stop operating Before you begin using your thermostat you should be familiar with its features and with the display and the location and operation of the thermostat buttons Your thermostat consists of two parts the thermostat cover and the base To remove the cover pull it straight out from the base To replace the cover line up the cover with the base and press until the cover