Rheem Solar Loline Conversion Kit Electric Wter Heater Water Heater User Manual

image

Contents

1. Notes Refer to item 4 of warranty conditions Rheem reserves the right to transfer fully functional components from the defective water heater to the replacement water heater if required The term water heater used in this Warranty and the Warranty Conditions and Exclusions means the Rheem supplied solar storage tank s solar collector s components and kit s In addition to this warranty the Trade Practices Act 1974 and similar laws in each state and territory provide the owner under certain circumstances with certain minimum statutory rights in relation to your Rheem water heater This warranty must be read subject to that legislation and nothing in this warranty has the effect of excluding restricting or modifying those rights FOR SERVICE TELEPHONE RHEEM AUSTRALIA PTY LTD 131 031 AUSTRALIA A B N 21 098 823 511 0800 657 335 NEW ZEALAND or refer local Yellow Pages Note Every care has been taken to ensure accuracy in preparation of this publication No liability can be accepted for any consequences which may arise as a result of its application 129872D 40
2. d Where the water heater is located in a position that does not comply with the Rheem water heater installation instructions or relevant statutory requirements causing the need for major dismantling or removal of cupboards doors or walls or use of special equipment to bring the water heater to floor level or to a serviceable position e Repairs to the water heater due to scale formation in the waterways when the water heater has been connected to a harmful water supply as outlined in the Owner s Guide and Installation Instructions booklet f Breakage of collector glass for any reason including hail damage We suggest that the collector glass be covered by your home insurance policy SUBJECT TO ANY STATUTORY PROVISIONS TO THE CONTRARY THIS WARRANTY EXCLUDES ANY AND ALL CLAIMS FOR DAMAGE TO FURNITURE CARPETS WALLS FOUNDATIONS OR ANY OTHER CONSEQUENTIAL LOSS EITHER DIRECTLY OR INDIRECTLY DUE TO LEAKAGE FROM THE WATER HEATER OR DUE TO LEAKAGE FROM FITTINGS AND OR PIPE WORK OF METAL PLASTIC OR OTHER MATERIALS CAUSED BY WATER TEMPERATURE WORKMANSHIP OR OTHER MODES OF FAILURE 39 RHEEM SOLAR WATER HEATER WARRANTY AUSTRALIA ONLY Rheem will a Repair or if necessary replace any Rheem water heater or b Replace any component or if necessary arrange the installation of a new water heater which falls within the Warranty Periods specified below in accordance with and subject to the following table co
3. 21 INSTALLATION SOLAR STORAGE TANR ed ra O d I HO WATER EN D i COLD Es NLE i CA P N I Pa Rheemglas Single Element Twin Element Single Element Twin Element Optima Storage Boost Top Bottom Dimensions A B C D E F G H J 111250 162250 411250 462250 Litres Litres Litres degrees degrees 111315 162315 411315 462315 111400 162400 411400 462400 INSTALLATION SOLAR STORAGE TANR TEMPERATURE AND PRESSURE RELIEF VALVE T amp PR VALVE DRAIN Drainpipe m from the ba t heater Discharge poi with BOOSTER HEATING UNIT AND THERMOSTAT COVER WATER NSULATED PIPE BLEED Drainpipe must terminate base of the Discharge point must comp ocal installation requirements NSULATED FITTINGS TER CONNECTION connection m ocal re julatio BLEED VALVE DRAIN Drainpipe mus from the bc of the nt must comply ation requirements OS INSULATED FITTINGS OUTDOOR LOCATION 23 INSTALLATION SOLAR CONTROL UNIT The solar control unit is designed to be mounted on the side of the solar storage tank with its location above and offset from the cold water inlet The solar control unit supplied with a 1 8 metre power cord requires a 220 240 V general power outlet GPO located within 1 2 metres of its
4. from the solar collectors and the solar hot and cold pipes e When water stops flowing from the solar hot and cold pipes reconnect the solar cold pipe to the circulator and tighten the compression fitting Close the bleed valve DRAINING THE WATER HEATER e Switch off the electrical supply at the isolating switch to the solar storage tank and at the power outlet for the solar control unit e Close the cold water isolation valve at the inlet to the water heater Close all hot water taps e Operate the relief valve release lever do not let the lever snap back or you will damage the valve seat Operating the lever will release the pressure in the water heater e Undo the union at the cold water inlet to the 5 way tee and attach a hose Let the other end of the hose go to a drain e Operate the relief valve again This will let air into the water heater and allow the water to drain through the hose 36 37 WATER SUPPLIES Your Rheem water heater is manufactured to suit the water conditions of most Australian metropolitan supplies However there are some known water supplies which can have detrimental effects on the water heater and its operation and or life expectancy If you are unsure of your water quality you can obtain information from your local water supply authority ANODE By using the correct colour coded anode this water heater can be used in areas where the total dissolved solids TDS content in the
5. caution must be observed when penetrating the jacket of the water heater Note Damage to the cylinder as a result of saddling to the jacket will void the warranty BOOSTER HEATING UNIT The booster heating unit s provides hot water during periods of low solar gain Single element models can be connected to either an Off Peak electricity supply or a continuous electricity supply Twin element models are to be connected with the bottom heating unit on an Off Peak electricity supply and the top heating unit on a continuous electricity supply Boosting can be controlled via a user operated manual switch Refer to Manual Controls on page 33 20 INSTALLATION SOLAR STORAGE TANR ASSEMBLY OF COLD WATER SUPPLY AND SOLAR PIPE CONNECTIONS Use thread sealing tape or approved thread sealant on all fittings All compression fittings must use brass or copper olives Ensure the air bleed valve is open when filling collectors HOT WATER OUTLET Provide a union for disconnection Insulate pipe COLD WATER INLET See cold water connection detail as applicable to your local requirements Provide a union for disconnection RELIEF VALVE A drain pipe must be fitted refer to page 30 BLEED VALVE A drain pipe must be fitted refer to page 30 SCHEMATIC OF 2 TEMPERATURE ZONES COLD WATER CONNECTION DETAIL USING A TEMPERATURE LIMITING DEVICE KITCHEN NON RETURN VALVE F NO INCORPORA TEI
6. in the northern hemisphere Where this orientation is not practical a system facing up to 45 from the equator will have its efficiency reduced by approximately W 5 e Inclination of the solar collectors should be approximately equal to the local latitude angle The latitudes of CIRE some Australian cities are listed Aspect below Solar collectors may be SOUTH re installed at the roof angle for NORTHERN HEMISPHERE simplicity of installation and appearance but must never be flat If the roof angle varies by 15 from the correct angle efficiency will be reduced by 5 e A flat roof stand is required for Ll fo installations where the roof angle is SS less than 10 SOUTHERN HEMISPHERE NORTH Recommended Aspect N E to N W NE E SE e The collector kit is suitable for installations vvith an inclination of up Se to 30 Where the solar collectors are installed at inclinations greater than 30 special roof fixings may be an necessary Refer to your local Rheem Solar Distributor for details e The installation of the solar collectors must comply with the requirements of AS NZS 3500 4 2 and all local codes and regulatory authority requirements The roof must be suitable to take the mass of the solar collectors Each solar collector weighs 34 kg when full of water Latitude of Some Australian Cities Adelaide 35 S Cairns Hobart 42 S Port Hedland 20 S Alice Springs 24 S Canberra M
7. not sure have your water quality checked against the conditions described on page 38 HOW LONG WILL THE WATER HEATER LAST There are a number of factors that will affect the length of service the water heater will provide These include the water quality the water pressure temperature inlet and outlet and the water usage pattern However your Rheem water heater is supported by a comprehensive warranty refer to page 40 ABOUT YOUR WATER HEATER ANODE PROTECTION The anode installed in your water heater will slowly dissipate whilst protecting the cylinder The life of the water heater cylinder may be extended by arranging for an authorised person to inspect the anode and replacing it if required The suggested time after installation when the anode should be inspected is Rheemglas 8 years Optima 10 years For softened water supplies or in areas of poor water quality it is recommended the anode be inspected 3 years earlier than shown refer to Water Supplies on page 38 BLEEDING THE SOLAR COLLECTORS It is necessary to purge air from the collector circuit e When the water heater is to be turned on and the solar collectors and solar hot and cold pipes have been drained e After maintenance has been conducted on the pipe work and air has entered the system If the circulator appears not to be circulating water around the system To purge air from the collector circuit e Ensure the solar storage tank is f
8. small amount of water from the solar storage tank through the solar pipe work during periods of low temperatures This is to prevent the water inside the pipe work from freezing It is essential that the electrical circuit to the solar control unit is continually turned on if there is a risk of freezing The solar warranty does not cover damage caused by freeze conditions when the electrical circuit to the solar control unit is turned off or interrupted Notes If it is necessary to switch the power off to the solar control unit and there is a risk of freezing then it is necessary to have your plumber drain the solar collectors and solar flow and return pipe work e The freeze protection system will be rendered inoperable if electrical power is not available at the solar control unit Damage caused by freezing due to no power at the solar control unit is not covered by warranty e Pipe work between the solar collectors and solar storage tank must be insulated e The system is not covered for freeze damage above 800 metres altitude e Refer to Warranty Exclusions on page 39 REGULAR CARE TEMPERATURE AND PRESSURE RELIEF VALVE This valve is near the top of the vvater heater and is essential for its safe operation It is possible for the valve to release a little water through the drain pipe during each heating period This occurs as the water is heated and expands by approximately 1 50 of its volume Never block the outlet of t
9. very high temperature e Close the bleed valve when water runs freely from the drain line 34 COMMISSIONING TO TURN OFF THE VVATER HEATER If it is necessary to turn off the water heater on completion of the installation such as on a building site or where the premises is vacant then e Close the cold water isolation valve at the inlet to the water heater e Switch off the electrical supply at the isolating switch to the solar storage tank and at the power outlet for the solar control unit Note The freeze protection system will be rendered inoperable if electrical power is not available Damage caused by freezing due to the unavailability of power to the solar control unit is not covered by warranty refer to Warranty Exclusions on page 39 If there is a risk of freezing then it is necessary to drain the solar collectors and connecting pipe work refer to Draining the Solar Collectors on page 36 35 DRAINING THE SOLAR COLLECTORS To drain the solar collectors and the solar hot and cold pipe e Turn off the water heater refer to To Turn Off the Water Heater on page 35 e Using a flat bladed screw driver open the bleed valve fitted adjacent to the 5 way tee at the cold water inlet of the water heater refer to diagram on page 34 e Undo the compression fitting at the top of the circulator located at the side of the solar control unit and disconnect the solar cold pipe Water will now drain
10. water and energy Replace faulty tap washers and have your plumber rectify any leaking pipe work e Are you using the booster heating unit properly Refer to Manual On Off Switch on page 12 and One Shot Control Switch on page 13 e Consider recent changes to your hot water usage pattern and check if there has been any increase in tariffs since your previous account ELECTRICITY TARIFFS The electricity tariff to which your solar water heater is connected will play an important role in the overall effectiveness of the system It is important you are aware of this tariff to enable you to take full advantage of the boosting period i e Domestic Continuous Off Peak Extended Off Peak For types of tariffs refer to How Your Water Heater Works on page 12 COLLECTOR GLASS Warranty DOES NOT cover breakage of solar collector glass Check your household insurance policy covers collector glass breakage Warning Collector glass should not be replaced whilst the solar collector is on the roof The solar collector must be disconnected and brought to ground level before replacing the collector glass Should the glass on a solar collector require replacement contact your nearest Rheem Service Office or Accredited Service Agent IF YOU HAVE CHECKED ALL THE FOREGOING AND STILL BELIEVE YOU NEED ASSISTANCE CALL YOUR NEAREST RHEEM SERVICE OFFICE OR ACCREDITED SERVICE AGENT 17 INSTALLATION SOLAR STORAGE TANR The syste
11. Omners Guide and Installation Instructions Solar Loline Conversion Kit Electric Water Heater s Install a Rheem VVARNING Plumber Be Avvare Use copper pipe ONLY Plastic pipe MUST NOT be used It is a requirement of a solar water heater installation that all pipe work be in copper and not plastic due to the effects of high water temperatures and pressures This water heater must be installed and serviced by an authorised person Please leave this guide with the householder A WARNING Plumber Be Aware The solar cold and hot pipes between the solar storage tank and the solar collectors MUST BE of copper and fully insulated with Armaflex insulation or similar minimum thickness 10 mm Plastic pipe MUST NOT be used as it will not withstand the temperature of the water generated by the solar collectors under stagnation conditions The solar collectors can generate extremely high water temperatures up to 150 C and high water pressure of 1000 kPa Plastic pipe cannot withstand these temperatures and pressures and MUST NOT be used Failure of plastic pipe can lead to the release of high temperature water and cause severe water damage and flooding Refer to Warning on page 29 PATENTS This water heater may be protected by one or more patents or registered designs in the name of Rheem Australia Pty Ltd CONTENTS HOUSEHOLDER VVe recommend you read pages 4 to 17 The other pages are intended for
12. ature has been proven to provide the required solar energy to meet the average family needs However in some circumstances it may be necessary to install an additional solar collector 14 SAVE A SERVICE CALL e Air in collectors no solar gain It is possible under certain conditions such as when the pipe work has been opened that air may become trapped in the solar collectors This will prevent the circulator from moving water around the collector circuit The air will need to be purged from the solar collectors refer to Bleeding The Solar Collectors on page 7 e Are you using more hot water than you think Is one outlet especially the shower using more hot water than you think Carefully review the family s hot water usage As you have installed an energy saving appliance energy saving must also be practised in the home Adjust your water usage pattern to take advantage of maximum solar gains Still have enjoyable showers but restrict the amount of hot water used by simply fitting an inexpensive flow control valve to your shower rose e Temperature and pressure relief valve running Is the relief valve discharging too much water Refer to Temperature and Pressure Relief Valve Running on page 16 e Thermostat setting Ensure the thermostat setting is appropriate You may choose to adjust Optima models or have your electrician adjust Rheemglas models the thermostat upwards to gain additional hot water capa
13. cause scalding It is necessary that a temperature limiting device such as the Rheem Temp Set be fitted between the water heater and the outlets in any ablution area such as a bathroom or ensuite when this water heater is installed to reduce the risk of scalding The installing plumber may have a legal obligation to ensure the installation of this water heater meets the delivery water temperature requirements of AS NZS 3500 4 2 so that scalding water temperatures are not delivered to a bathroom ensuite or other ablution area refer to diagram on page 21 19 INSTALLATION SOLAR STORAGE TANR REDUCING HEAT LOSSES VVe recommend the first 1 5 to 2 m of the hot vvater line coming out of the vvater heater be insulated vvith vveatherproof insulation In addition the insulation of the hot water line from the water heater must comply with the requirements of AS NZS 3400 4 2 ANODE TYPES The correct anode type for the water supply being used must be fitted in the water heater refer to Water Supplies on page 38 The black anode is standard Total Dissolved Solids in water supply to the water heater Anode colour code 0 40 mg L Green 40 600 mg L Black 600 2500 mg L Blue SADDLING PIPE WORK To prevent damage to the cylinder when attaching pipe clips or saddles to the water heater jacket we recommend the use of self drilling screws with a maximum length of 12 mm Should pre drilling be required extreme
14. city when boosting e Water heater size Do you have the correct size water heater for your requirements The sizing guides in the sales literature and on the Rheem website www rheem com au suggest average sizes that may be needed WATER NOT HOT ENOUGH You may find that due to heavy hot water usage or low solar energy gain the water temperature may be lower than normally expected You will need to carefully plan your use of the booster heating unit to boost the water temperature on such occasions A lower water temperature may also be noticed in the morning when the booster heating unit has not been switched on overnight This in particular may be experienced during periods of low solar energy gain or if there has been heavy hot water usage the previous night 15 SAVE A SERVICE CALL TEMPERATURE AND PRESSURE RELIEF VALVE RUNNING e Normal Operation It is normal and desirable this valve allows a small quantity of water to escape during the heating cycle However if it discharges more than a bucket full of water in 24 hours there may be another problem e Continuous dribble Try gently raising the easing lever on the relief valve for a few seconds refer to Temperature and Pressure Relief Valve on page 9 This may dislodge a small particle of foreign matter and clear the fault Release the lever gently e Steady flows for long period often at night This may indicate the mains water pressure sometimes rises above t
15. d Water adjustable thermostat which allows you to Temperature choose the most suitable boost Maximum Recommended Supply Temperature to Bathrooms and Ensuites temperature for your hot water needs The Rheemglas model features a tradesperson adjustable thermostat This requires a licensed tradesperson to make any temperature adjustments The temperature is adjustable within the range shown in the diagram opposite For reasons of safety and economy we advise you adjust the thermostat to the lowest setting which meets your needs especially if there are young children or elderly people in the home ABOUT YOUR WATER HEATER HOTTER WATER INCREASES THE RISK OF SCALD INJURY We recommend and it may also be required by regulations that an approved temperature limiting device such as the Rheem Temp Set be fitted into the hot water piping to the bathroom and ensuite when this water heater is installed This will keep the water temperature below 50 C at the bathroom and ensuite The risk of scald injury will be reduced and still allow hotter water to the kitchen and laundry This temperature limiting device may be required by regulations TEMPERATURE ADJUSTMENT OPTIMA To adjust the temperature push in the child resistant knob and turn anti clockwise to decrease or clockwise to increase the temperature setting The Optima has a minimum temperature setting of 60 C anda maximum temperature setting of 75 C WARNING This water heater is
16. e air bleed valve and non return valve assembly 11 and 5 way tee 2 from the solar hot pipe to the inlet of the solar storage tank with the 220mm x 35mm diam insulation 13 and secure with the cable ties 14 provided Note Use thread sealing tape or an approved thread sealant on all fittings to solar from solar collectors i collectors refer to the installation diagram on page 26 for assembly details of solar cold and hot pipe connections Solar Storage Tank with Solar Control Unit 25 INSTALLATION SOLAR CONTROL UNIT SOLAR HOT PIPE SUPPLIED IN SOLAR LOLINE CONVERSION KIT 1 Nipple BSP X G7 9 Screws 2 5 way tee 10 Cold sensor probe 4 Preformed pipe DN15 11 Air bleed valve and non return valve assembly 5 Compression nut 12 Insulation 280 mm long x 12 mm diam 6 Olive 13 Insulation 220 mm long x 35 mm diam 7 Circulator 14 Cable tie 8 Solar control unit INSTALLATION OF SOLAR COLLECTORS Refer to page 27 for information on solar collector location Refer to the installation instructions supplied with the collector kit for details on the installation of the solar collectors 26 INSTALLATION SOLAR COLLECTORS SOLAR COLLECTOR LOCATION Solar collectors must be installed in a shade free position and located as follows e The solar collectors are to installed facing toward the equator i e north facing in the southern hemisphere and south facing
17. e water heater has been switched off e Switch on the electrical supply to the solar storage tank at the isolating switch e Switch on the electrical supply to the solar control unit at the power outlet HOW DO I KNOW IF THE WATER HEATER IS INSTALLED CORRECTLY Installation requirements are shown on pages 23 and 26 The water heater must be installed by an authorised person and the installation must comply with national codes AS NZS 3500 4 2 AS NZS 3000 and all local codes and regulatory authority requirements In New Zealand the installation must conform with the New Zealand Building Code Note The solar hot and cold pipe work between the solar storage tank and the solar collectors must be of copper and fully insulated with Armaflex insulation or similar minimum thickness 10 mm The insulation must be weatherproof if exposed and fitted up to the connections on the storage tank as very high temperature water can flow from the solar collectors to the storage tank under certain conditions Plastic pipe must not be used as it will not withstand the temperature of the water generated by the solar collectors under certain conditions refer to Warning on page 29 DOES THE WATER QUALITY AFFECT THE WATER HEATER The water heater is suitable for most public water supplies however some water qualities may have detrimental effects on the cylinder solar collectors and fittings If you are in a known harsh water area you must read page 38 If you are
18. eater Rheem recommends as an optional extra a second switch called the Booster Switch be installed in a convenient location such as the kitchen or laundry This switch should be a normal on off manually operated switch recommended for Off Peak electricity supplies to single element models and the bottom element on twin element models or the Rheem One Shot Control switch recommended for continuous electricity supplies to single element models only The amount of water heated by the booster heating unit depends on the model of water heater installed The boosted volumes of hot water are Model 250 L 315L 400 L Lovver Heating Unit all models 250 litres 315 litres 400 litres Top Heating Unit twin element models 50 litres 50 litres 90 litres MANUAL ON OFF SVVITCH a Continuous Tariff Connection Operate the booster switch to activate the auxiliary booster heating unit when the hot water falls below an acceptable temperature It is important to ensure the booster switch is turned OFF after you have satisfied your hot water needs Do not leave the booster switch ON in sunlight hours because your solar savings will be reduced b Extended Off Peak Tariff Connection CS Operation is very similar to that suggested for continuous tariff but it is important to be aware of the hours during which electricity is available so boosting if required can be adapted to suit Check with your local Electric
19. eating unit is automatically turned OFF when the water temperature reaches the thermostat setting It is not necessary to activate the booster heating unit every time the neon light is on the neon light indicates the water is more than 6 C below the thermostat setting The water may still be at a usable temperature for some purposes e g showering and you may not need to use hot water for some hours during which time the water may be heated by the sun Remember even on cloudy days your solar water heater can receive diffused radiation which will heat some of your stored water On these days you will need to operate the booster heating unit only as desired For summer operation it is recommended trial periods be undertaken to determine if it is necessary to turn the booster switch or one shot control on at all GOING ON HOLIDAYS If you plan to be away from home for a few nights we suggest you leave the water heater switched on If you plan to be away for a longer period conserve energy by switching the booster switch OFF It is not necessary to switch off the electrical supply at the power outlet to the solar control unit Refer to To Turn Off The Water Heater on page 5 Also if the system is not used for a period in excess of 4 weeks it is recommended the solar collectors be covered 13 SAVE A SERVICE CALL Check the items below before making a service call You will be charged for attending to any condition
20. ection is suited to where the storage capacity is less than the normal daily usage e Off Peak electricity supply This type of connection will only allow boosting to occur during set hours A volume of water sufficient for the days total use is heated and stored This type of boosting may be more economical due to reduced tariffs by the electricity authority TWIN ELEMENT MODELS This type of water heater has two heating units each with its own thermostat One heating unit is at the base of the water heater and the other near the top e Lower heating unit During normal operation this heating unit supplies all of the boosted hot water during periods of low solar energy gain e Top heating unit This heating unit only operates during periods of high demand to provide an additional supply of boosted water e Electrical connection The two heating units are wired for non simultaneous operation and only one heating unit can operate at a time The lower heating unit is usually connected to the Off Peak electricity supply and the top heating unit to a continuous supply Some electricity suppliers allow both heating units to be metered at the Off Peak or controlled tariff NOTE Power must be available to the top heating unit circuit at all times for this water heater to operate as designed 11 HOW YOUR WATER HEATER WORKS MANUAL CONTROLS An isolating switch is installed in your electrical meter box for your solar water h
21. ection union The pipe work from the bleed valve to the drain should be as short as possible and fall all the way from the valve with no restrictions It should have no more than three right angle bends in it Use DN15 pipe The outlet of the drain pipe must be in such a position that flow out of the pipe can be easily seen refer to AS NZS 3500 4 2 but arranged so water discharge will not cause injury damage or nuisance The water discharged may be of a high temperature under certain conditions 30 CONNECTIONS PLUMBING EXPANSION CONTROL VALVE Local regulations may make it mandatory to install an expansion control valve ECV in the cold water supply line In other areas ECVs are not required unless the saturation index is greater than 0 4 refer to Water Supplies on page 38 However they may be needed in corrosive water where there are sufficient quantities of silica dissolved in the water A drain line must be run separately from the drain of the relief valve 31 CONNECTIONS ELECTRICAL The power supply must not be turned on until the solar storage tank is filled with water and a satisfactory megger reading is obtained The solar storage tank with an electric booster heating unit is designed for direct connection to a 240 V AC 50 Hz mains power supply with an isolating switch installed at the switchboard Flexible 20 mm conduit is required for the electrical cable to the solar storage tank The conduit is to be connec
22. floor level and must stand vertically upright Remember all local authorities have regulations i about putting water heaters into roof spaces 18 INSTALLATION SOLAR STORAGE TANR SAFE TRAY It is a requirement of the National Plumbing Code AS NZS 3500 4 2 that for new installations all water heaters be installed in a safe tray where in the event of a leak property may be damaged Installation of such trays must comply with Clause 4 4 and Sub clauses1 to5 of the above mentioned code MAINS WATER SUPPLY Where the mains water supply exceeds that shown in the table below an approved pressure limiting valve is required and should be fitted as shown in the installation diagram refer to diagram on page 21 Model 250 315 400 litre Relief valve setting 1000 kPa Expansion control valve setting 850 kPa Max mains supply pressure With expansion control valve 680 kPa Without expansion control valve 800 kPa Expansion control valve not supplied with the water heater TANK WATER SUPPLY If the water heater is supplied with water from a tank supply then the bottom of the supply tank must be at least 1 m above both the solar collectors and the highest hot water outlet Take care to avoid air locks The cold water supply line to the water heater should be adequately sized and fitted with a full flow gate valve or ball valve HOT WATER DELIVERY This water heater can deliver water at temperatures which can
23. he designed pressure of the water heater Ask your installing plumber to fit a pressure limiting valve NEVER replace the relief valve with one of a higher pressure rating e Heavy flows of hot water until the water heater is cold then stops until water reheats The water heater must be switched off at the isolating switch or switchboard Phone your nearest Rheem Service Department or Accredited Service Agent to arrange for an inspection EXPANSION CONTROL VALVE RUNNING If an expansion control valve is fitted in the cold water line to the water heater refer to page 21 it may discharge a small quantity of water instead of the Temperature and Pressure Relief valve on the water heater The benefit is that energy is conserved as the discharged water is cooler 16 SAVE A SERVICE CALL HIGH ELECTRICITY BILLS With the installation of your new solar hot water system maximum electrical energy savings can be achieved with careful planning of hot water usage Should you at any time feel your electricity account is too high we suggest you check the following points Is the relief valve running excessively Refer to Temperature and Pressure Relief Valve Running on page 16 e Is one outlet especially the shower using more hot water than you think Refer to Not Enough Hot Water on page 14 e Is there a leaking hot water pipe dripping hot water tap etc Even a small leak will waste a surprising quantity of hot
24. his valve or its drain pipe for any reason Lift until water flows Operate the easing lever on the temperature and Ed ae pressure relief valve once every six months It iS lower gently Drain very important you raise and lower the lever ene gently If water does not flow freely from the drain line when the lever is lifted then the water heater should be checked by the Rheem Service Department of their Accredited Service Agent Water Heater The temperature and pressure relief valve should be checked for performance or replaced at intervals not exceeding 5 years or more frequently in areas where there is a high incidence of water deposits refer to Water Supplies on page 38 EXPANSION CONTROL VALVE In South Australia and Western Australia an expansion control valve is fitted to the cold supply pipe to the water heater Water will flow from its drain line during the heating period In scaling water areas an expansion control valve should be fitted to the cold water supply line to the water heater SAFETY This water heater is supplied with a thermostat an over temperature cut out and a combination temperature and pressure relief valve These devices must not be tampered with or removed The water heater must not be operated unless each of these devices is fitted and is in working order If the power supply cord or plug to the solar control unit is damaged it must be replaced by an authorised person in order to avoid a hazard P
25. hone your nearest Rheem Service Department or Accredited Service Agent to arrange for an inspection The warranty can become void if relief valves or other safety devices are tampered with or if the installation is not in accordance with these instructions SOLAR COLLECTOR GLASS Ensure the glass on your solar collectors is free of dust salt spray or any other matter which may reduce the effectiveness of the solar collectors Hose or wash the collector glass with water and a soft brush when the solar collectors are cool Trim any trees which may shade the solar collectors HOW YOUR WATER HEATER WORKS The Rheem solar Loline system has its vitreous enamel lined solar storage tank installed at ground or floor level remotely from the solar collectors As the sun heats the water in the solar collectors the increase in temperature activates the circulator The circulator then moves the water from the solar collectors through an insulated copper pipe to the solar storage tank The circulator switches on whenever the water in the solar collectors is hotter than the water in the tank Cooler water from the solar storage tank is circulated to the solar collectors to be heated by the sun s energy This process continues while solar energy is available and until the water in the solar storage tank reaches a temperature of approximately 75 C MAINS PRESSURE The water heater is designed to operate at mains pressure by connecting directly to the main
26. ildura 34 S Rockhampton 24 S Brisbane 27 S Darwin Melbourne 38 S Sydney 34 S Broken Hill 31 S Geraldton Perth 32 S Townsville 19 S 27 CONNECTIONS PLUMBING CONNECTION SIZES e Hot water connection RP24 20 P P KZ e Cold water connection R 4 20 DISTUBE OR cold water inlet to tank RP34 20 Lay FITTING EINE e Solar hot from collector connection DN15 compression fitting e Solar cold to collector connection SS gt NLET DN15 compression fitting Z oy i e Relief valve connection RP4 15 LD e Bleed valve connection G1 0B e Expansion control valve connection when fitted RP72 15 INLET OUTLET CONNECTIONS A disconnection union must always be provided at the cold water inlet and hot water outlet on the water heater to allow for disconnection of the water heater All water heaters have a plastic dip tube or fitting liner in the inlet and outlet fittings see diagram These must be in place for the water heater to function properly Do not remove or damage them by using heat nearby They will be pushed into the correct position as the fitting is screwed in A non return valve must be installed on the cold water supply pipe to the solar storage tank Use the arrangement shown in the installation diagram refer to page 21 The plumbing arrangements for the cold water inlet and solar cold and hot pipes are shown on page 26 The pipe work must be cleared of foreign matter bef
27. installation If the installation is outdoors the power outlet must be weatherproof refer to Connections Electrical on page 32 Note Care must be taken when mounting the solar control unit to the side of the solar storage tank Damage to the cylinder as a result of mounting the solar control unit to the jacket will void the warranty refer to Saddling Pipe Work on page 20 SOLAR CONVERSION OF A RHEEM ELECTRIC WATER HEATER To connect the solar cold and hot pipes and mount the solar control unit on a Rheem electric water heater without a raised solar hot inlet Numbers in parentheses refer to items on diagram on page 26 e Fit the 5 way tee 2 to the cold water inlet of the solar storage tank Ensure the rounded tube snorkel is orientated upwards when inserted into the solar storage tank the cold sensor housing is orientated horizontally to the front of the solar storage tank and the solar cold outlet is orientated vertically upwards e Connect the DN15 preformed pipe 4 to the solar cold outlet connection using the compression nut 5 and olive 6 provided e Fit a BSP x G nipple 1 to the outlet of the circulator 7 in the solar control unit 8 ensure the compression end of the nipple is exposed e Locate the solar control unit 8 by connecting the DN15 preformed pipe 4 to the nipple on the inlet of the circulator 7 using the compression nut 5 and olive 6 provided e Secure the solar contro
28. instructed by the installer on how to dissipate the gas safely SATURATION INDEX The saturation index is used as a measure of the water s corrosive or scaling properties In a scaling water supply calcium carbonate is deposited out of the water onto any hot metallic surface When water has a saturation index greater than 0 40 an expansion control valve must be fitted on the cold water supply after the non return valve and the solar collectors should be covered when the water heater is not intended to be used for extended periods Where the saturation index exceeds 0 80 a water softening device and a low watts density element should be fitted Where the saturation index is less than 1 0 a corrosion resistant heating unit should be used contact your nearest Rheem Service Department or Accredited Service Agent Refer to the cold water connection detail on page 21 WATER HEATERS NOT INSTALLED IN ACCORDANCE WITH THE ABOVE ADVICE WILL NOT BE COVERED BY THE RHEEM WARRANTY 38 RHEEM SOLAR WATER HEATER WARRANTY AUSTRALIA ONLY WARRANTY CONDITIONS This warranty is applicable only to water heaters manufactured from 1st August 2002 The water heater must be installed in accordance with the Rheem water heater installation instructions supplied with the water heater and in accordance with all relevant statutory and local requirements of the State in which the water heater is installed Where a failed component or water hea
29. ipe must be fitted to the relief valve to carry the discharge clear of the water heater Connect the drain line to the relief valve using a disconnection union The pipe work from the relief valve to the drain should be as short as possible and fall all the way from the water heater with no restrictions It should have no more than three right angle bends in it Use DN15 pipe The outlet of the drain pipe must be in such a position that flow out of the pipe can be easily seen refer to AS NZS 3500 4 2 but arranged so hot water discharge will not cause injury damage or nuisance The relief line must discharge at an outlet or air break not more than 9 metres from the relief valve In locations where water pipes are prone to freezing the drain pipe must be insulated and not exceed 300 mm in length In this instance the drain pipe is to discharge into a tundish through an air gap of between 75 mm and 150 mm Warning As the function of the Temperature and Pressure Relief valve on this water heater is to discharge high temperature water under certain conditions it is strongly recommended the pipe work downstream of the relief valve be capable of carrying water exceeding 93 C Failure to observe this precaution may result in damage to pipe work and property BLEED VALVE DRAIN A drain pipe must be fitted to the bleed valve to carry the discharge clear of the water heater and solar controls Connect the drain line to the bleed valve using a disconn
30. ity Supply Authority for hours of operation Do not leave the booster switch on during daylight hours unless boosting is required as solar savings will be reduced c Off Peak night rate Tariff Connection Most systems will be connected to an Off Peak supply of electricity Boosting will only occur overnight usually between 11 00 PM and 6 00 AM In the winter months many households will find it necessary to leave the booster switch ON However in some cases it may only be necessary to switch the booster switch ON every second night This can be determined over a trial period 12 HOW YOUR WATER HEATER WORKS ONE SHOT CONTROL SWITCH The One Shot Control switch has been specially developed to help provide maximum savings with electrically boosted solar water heaters connected to a continuous electricity supply Power must be available to the One Shot Control switch before the booster heating unit can be activated The switch has a push button operation and incorporates a neon light indicator This neon light will come on when the water in the boosted section of the solar storage tank falls more than 6 C below the thermostat setting indicating boosting may be required When you decide the hot water is below L a usable temperature and additional hot To BOOST WATER TEMPERATURE water is required press the control button The neon light will go out and the booster heating unit will be turned ON The booster h
31. l unit 8 to the solar storage tank using the four screws 9 provided e Connect the solar cold pipe to the collector to the nipple 1 on the outlet side of the circulator 7 using the compression nut 5 and olive 6 provided Insert the cold sensor probe 10 into the cold sensor housing on the 5 way tee 2 ensuring the O ring is in position on the probe Lock it into position with the locking washer and clip provided e Connect the hot sensor lead from the solar collector installation to the hot sensor cable connector at the underside of the solar control unit 8 24 INSTALLATION SOLAR CONTROL UNIT Insulate the preformed pipe 4 with the 280mm long x 12 mm diam insulation 12 and secure with the cable ties 14 provided e Fit the air bleed valve and non return valve assembly 11 to the solar hot water inlet of the 5 way tee 2 Ensure the bleed valve outlet is orientated downwards at a slight angle to the horizontal and to the rear of the solar storage tank e Connect a drain line to the bleed valve refer to Bleed Valve Drain on page 30 e Fit a BSP x G nipple 1 to the end inlet of the air bleed valve and non return valve assembly 11 ensure the compression end of the nipple is exposed e Connect the solar hot pipe from the collector to the nipple 1 on the air bleed valve and non return valve assembly 11 using the compression nut 5 and olive 6 provided 6 Insulate th
32. lectors to be roof mounted and the solar storage tank to be installed at ground level The solar storage tank is suitable for either outdoor or indoor installation The system is suitable for installation and offers protection against freeze damage in areas up to 800 metres altitude The system is not covered for freeze damage above 800 metres altitude refer to Warranty on page 40 The model you have chosen will be either a Rheemglas or an Optima model The Optima model has a temperature adjusting knob on the lower front of the water heater Both the Rheemglas and Optima models are available with either a single element or with twin elements refer to Single Element Models on page 11 and Twin Element Models on page 11 HOW HOT SHOULD THE WATER BE The solar control unit will circulate water through the solar collectors until a Typical Maximum temperature of approximately 75 C is Temperature from Da Solar Gain and reached During periods of low solar Optima Maximum energy gain the water temperature can Thermostat Setting be boosted by the thermostatically Top Element Rheemglas controlled electric booster heating unit Thermostat Setting MES IC Ui This may be operated manually or not adjustable Thermostat automatically depending on how it is Setting wired Refer to pages 12 and 13 or check FS Ree with your electrician Thermostat Setting and Recommended The Optima model features a user Store
33. m is suitable for installation and offers protection against freeze damage in areas up to 800 metres altitude The system has NO VVARRANTY for freeze damage above 800 metres altitude refer to Warranty on page 40 THIS VVATER HEATER IS NOT SUITABLE FOR POOL HEATING SOLAR WATER HEATER STORAGE TANK LOCATION The solar water heater storage tank is suitable for either outdoor or indoor installation Whether located outdoor or indoor the solar water heater storage tank should be installed close to the most frequently used outlet and its position chosen with safety and service in mind Clearance must be allowed for servicing of the water heater The solar water heater storage tank must be accessible without the use of a ladder or scaffold Make sure the Temperature and Pressure Relief valve lever is accessible and the front cover thermostat and booster heating unit can be removed for service You must be able to read the information on the rating plate If possible leave headroom of one water heater length so the anode can be inspected or replaced Remember you may have to remove the entire water heater later for servicing The installation must comply with the requirements of AS NZS 3500 4 2 AS NZS 3000 and all local codes and regulatory authority requirements In New Jf fo Zealand the installation must er conform with the New Zealand Building Code It is recommended the solar i storage tank be installed at ground or
34. n by a Rheem Accredited Service Agent or the Rheem Service Department b Where it is found there is nothing wrong with the water heater where the complaint is related to excessive discharge from the temperature and or pressure relief valve due to high water pressure where there is no flow of hot water due to faulty plumbing where water leaks are related to plumbing and not the water heater or water heater components where there is a failure of gas electricity or water supplies where the supply of gas electricity or water does not comply with relevant codes or acts c Where the water heater or water heater component has failed directly or indirectly as a result of excessive water pressure excessive temperature and or thermal input corrosive atmosphere ice formation in the water ways of a water heater system without a freeze protection system ice formation in the water ways of a solar Hiline water heater system installed at an altitude more than 600 metres above sea level ice formation in the water ways of a solar Loline water heater system installed at an altitude more than 800 metres above sea level ice formation in the water ways of a water heater system with a freeze protection system where the electricity supply has been switched off or has failed ice formation in the water ways of a solar water heater system where the system has not been installed in accordance with the Rheem water heater installation instructions
35. nditions and exclusions Installation Model Period Warranty All Components from date of installation Year New component solar collector or water heater at Al istallaons ALMOUEIS 1 Rheem s sole discretion free of charge including labour Cylinder from date of installation Rheemglas ved New water heater free of charge including labour Hiline 2 amp 3 Water heater installed in a talitte Years New water heater free of charge with installation and single family domestic 485 labour costs being the responsibility of the owner dwelling with a thermostat Years setting below 76 C Optima 2t05 New water heater free of charge including labour Heavy Duty Years New water heater free of charge with installation and 6to 10 labour costs being the responsibility of the owner Water heater installed in Rheemglas any other than a single Hiline family domestic dwelling Loline Years New water heater free of charge with installation and 2 amp 3 labour costs being the responsibility of the owner with a thermostat setting Optima Years New water heater free of charge with installation and below 76 C Heavy Duty 2to5 labour costs being the responsibility of the owner Solar Collector from date of installation Years New solar collector free of charge with installation and Alifsrallakong dE a 2to5 labour costs being the responsibility of the owner
36. not intended to be operated adjusted or tampered with by young children or infirm persons Young children should be supervised to ensure they do not interfere with the water heater Care should be taken not to touch the pipe work connecting the solar collectors and the solar storage tank Under certain conditions very high temperature hot water can be generated by the solar collectors and flow through the pipe work TO TURN OFF THE WATER HEATER If you plan to be away from home for a few nights we suggest you leave the water heater switched on If it is necessary to turn off the water heater e Close the cold water isolation valve at the inlet to the water heater e Switch off the electrical supply at the isolating switch to the solar storage tank e Switch off the electrical supply at the power outlet to the solar control unit refer to note below Note If there is a risk of freezing conditions the electrical supply to the solar control unit should not be switched off unless the solar collectors are drained otherwise damage could result refer to Freeze Protection on page 8 ABOUT YOUR WATER HEATER TO TURN ON THE WATER HEATER e Open the cold water isolation valve fully at the inlet to the water heater 9 If the solar collectors and solar hot and cold pipes have been drained it will be necessary to bleed the collector circuit refer to Bleeding the Solar Collectors on page 7 If the electrical supply to th
37. ntities of hot water Dishwasher running costs can be adversely affected if the thermostat is set below 65 C The thermostat can be adjusted within the range shown on page 4 32 CONNECTIONS ELECTRICAL MANUAL CONTROLS A manual switch can be installed in the power supply circuit to the solar storage tank The on off booster switch can be installed with a single element model connected to either a continuous or an Off Peak electricity supply or with a twin element model to control the bottom heating unit connected to an Off Peak electricity supply The One Shot Control switch should only be installed with a single element model connected to a continuous electricity supply Discuss the power supply and manual switching arrangements with the householder A A i N N E E E E Electrical installation of a twin Electrical installation of a single element model solar storage tank element model solar storage tank with a manual boosting switch with a manual boosting switch controlling the bottom heating unit WIRING DIAGRAM FOR TWIN ELEMENT ELECTRIC WATER HEATERS NON SIMULTANEOUS OPERATION The active from the continuous electricity supply must be connected to the top heating unit circuit and the active from the Off Peak electricity supply must be connected to the bottom heating unit circuit for the water heater to operate COMMISSIONING TO FILL AND TURN ON THE VVATER HEATER The power
38. or fault that is not related to manufacture or failure of a part NOT ENOUGH HOT WATER OR NO HOT WATER e Insufficient sunlight Insufficient sunlight due to cloudy weather during summer months or low solar energy contribution in winter months may mean you will need to switch on the booster heating unit more often e Booster heating unit not operating Inspect the isolating switch marked HOT WATER or WATER HEATER switchboard and the booster switch if one is installed and ensure they are turned ON Check the electrical tariff to which the unit is connected If on Of Peak remember heating hours are restricted refer to Off Peak Tariff on page 12 Check the fuse marked water heater Check the fuse marked HOT WATER or WATER HEATER at the switchboard e Twin element models For twin element non simultaneous models power must be available to the top heating unit circuit at all times for this water heater to operate as designed e Solar Control Unit Check the power outlet to the solar control unit is switched on e Collectors shaded If trees or other objects shade the solar collectors or if the glass is dirty the effectiveness of the solar collectors will be greatly reduced Clean the collector glass trim trees or relocate the solar collectors if the obstruction is permanent e Collector area is too small For most installations the number of solar collectors recommended in Rheem liter
39. ore connection and purged before attempting to operate the water heater PIPE SIZES The solar cold and hot pipes between the solar storage tank and the solar collectors should be a minimum DN15 The cold water pipe to the water heater should be the same size or bigger than the hot water line from the water heater For best results choose the most suitable pipe size for each individual application Refer to the relevant plumbing regulations 28 CONNECTIONS PLUMBING A VVARNING Plumber Be Avvare e The solar cold and hot pipes between the solar storage tank and the solar collectors MUST BE of copper and fully insulated with Armaflex insulation or similar minimum thickness 10 mm e The insulation must be weatherproof if exposed and fitted up to the connections on both the solar collectors and the storage tank as very high temperature water can flow from the solar collectors to the solar storage tank under certain conditions The insulation will also offer corrosion protection to a metal roof against water runoff over the copper pipe e Plastic pipe MUST NOT be used as it will not withstand the temperature of the water generated by the solar collectors under stagnation conditions The solar collectors can generate extremely high water temperatures up to 150 C and high water pressure of 1000 kPa Plastic pipe cannot withstand these temperatures and pressures and MUST NOT be used Failure of plastic pipe can lead to the relea
40. s water supply If the mains supply pressure in your area exceeds that shown on page 19 a pressure limiting valve must be fitted The supply pressure should be greater than 350 kPa for true mains pressure operation to be achieved ELECTRIC BOOSTING Water stored in the solar storage tank can be heated by an electric booster heating unit The booster heating unit is for heating the water at times of low solar energy gain such as during very cloudy or rainy weather or during the winter months The booster heating unit is controlled by an electric thermostat The thermostat and its over temperature energy cut out are mounted on the solar storage tank behind the front cover The water temperature is automatically controlled to the thermostat setting when the booster heating unit is energised The Optima models feature a user adjustable thermostat which allows you to choose the most suitable boost temperature for your hot water needs It has a minimum temperature setting of 60 C and a maximum temperature setting of 75 C The thermostat on the Rheemglas models is tradesperson adjustable It has a minimum temperature setting of 60 C and a maximum temperature setting of 70 C It can only be adjusted by an authorised person Automatic safety controls are fitted to the water heater to provide safe and efficient operation 10 HOW YOUR WATER HEATER WORKS SINGLE ELEMENT MODELS e Continuous electricity supply This type of conn
41. se of high temperature water and cause severe water damage and flooding e There must be a continuous fall in the pipe work between the solar collectors and storage tank The highest point of the solar cold pipe and solar hot pipe must be where they connect to the solar collectors to avoid the possibility of air locks occurring in the system PIPE LENGTHS The maximum recommended combined length of the solar cold and solar hot pipes with bends is Maximum recommended pipe length and number of 90 bends Pipe 1 or 2 Collectors 3 Collectors 4 Collectors i Size Pipe 90 Pipe 90 Pipe 90 Length Bends Length Bends Length Bends DN15 40 metres 20 30 metres 20 NA NA DN18 60 metres 20 40 metres 20 32 metres 20 For each additional 90 bend reduce the maximum total pipe length by 0 5 metres For each additional metre of pipe length reduce the number of 90 bends by two 29 CONNECTIONS PLUMBING RELIEF VALVE The Temperature and Pressure Relief valve must be fitted before the vvater heater is operated Before fitting the relief valve make sure the probe has not been bent Seal the thread with Teflon tape never hemp Make sure the tape does not hang over the end of the thread Screw the valve into the correct opening refer to the installation diagram on page 23 leaving the valve outlet pointing downwards Do not use a wrench on the valve body use the spanner flats provided RELIEF VALVE DRAIN A drain p
42. supply to the solar storage tank and solar control unit must not be switched on until the water heater is filled with water and a satisfactory megger reading is obtained e Open all of the hot water taps in the house don t forget the shower Open the cold water isolation valve fully to the water heater Air will be forced out of the taps As water flows freely from each tap close it Check the piping for leaks e Bleed the solar collectors refer to Bleeding the Solar Collectors on page 34 e Switch on the electrical supply at the isolating switch to the solar storage tank e Plug in the solar control unit and switch the power on Explain to the householder the functions and operation of the solar water heater BLEEDING THE SOLAR COLLECTORS Upon completion of the installation it is necessary to purge the air from the collector circuit To purge air from the collector circuit e Ensure the solar storage tank is full of water and all of the hot taps are turned off e Using a flat blade screwdriver open the bleed valve fitted adjacent to the 5 way tee at the cold water inlet of the water heater see diagram e The mains pressure will force water to flow from the tank and through the pipe work forcing air from the collector lt circuit through the bleed valve This is evidenced by spurting of water from the drain line connected to the bleed valve air bleed valve Warning Exercise caution as water may be at a
43. ted to the unit with a 20 mm terminator Connect the power supply wires directly to the terminal block and earth tab connection ensuring there are no excess wire loops inside the front cover The solar control unit supplied with a 1 8 metre power cord requires a 240 V general power outlet GPO to be located within 1 2 metres of the installation The GPO is required to be weatherproof for outdoor installations If the power supply cord is damaged it must be replaced in order to avoid a hazard ASSEMBLY OF ADJUSTER MECHANISM ON OPTIMA MODELS When the front cover has been removed reassemble as follows e Remove the knob from the front cover by depressing the locking tabs on the inside of the front cover H _ THERMOSTAT e Turn the thermostat to the lowest ADAPTOR temperature refer to Temperature Es Adjustment Optima on page 5 N a e ees dama e Fit the front cover e Insert the connector shaft through the lL oe hole into the thermostat adaptor slots i we e Align the knob slots over the T drive ON ppont coven the connector shaft with the dial at the lowest setting a firm push with the hand on the knob front face will engage the locking tabs THERMOSTAT SETTING The water heater thermostat should be set at the lowest temperature that will provide sufficient hot water Discuss with the user to determine the lowest thermostat setting to ensure sufficient qua
44. ter is replaced under warranty the balance of the original warranty period will remain effective The replaced part or water heater does not carry a new warranty Where the water heater is installed outside the boundaries of a metropolitan area as defined by Rheem or further than 25 km from a regional Rheem branch office or an Accredited Service Agent the cost of transport insurance and travelling costs between the nearest Rheem Accredited Service Agent s premises and the installed site shall be the owner s responsibility The warranty only applies to the water heater and original or genuine company component replacement parts and therefore does not cover any plumbing or electrical parts supplied by the installer and not an integral part of the water heater e g pressure limiting valve isolation valves non return valves electrical switches pumps or fuse The water heater must be sized to supply the hot water demand in accordance with the guidelines in the Rheem water heater literature WARRANTY EXCLUSIONS REPAIR AND REPLACEMENT WORK WILL BE CARRIED OUT AS SET OUT IN THE RHEEM WATER HEATER WARRANTY HOWEVER THE FOLLOWING EXCLUSIONS MAY CAUSE THE WATER HEATER WARRANTY TO BECOME VOID AND MAY INCUR A SERVICE CHARGE AND OR COST OF PARTS a Accidental damage to the water heater or any component including Acts of God failure due to misuse incorrect installation attempts to repair the water heater other tha
45. the installer but may be of interest About your water heater eeaaannnnnnanmmananananananananannnnr 4 Regular Caroemmesi ssomnsmtanmms Aa s OAA a aeaa aa EAE 9 How your water heater works cccccccceeeeeeeeeeeeeeeeeeeeeeeeeeeeeeneeeeeeees 10 Save a service call icp vests eres ee tee ed eed 14 Installation Solar storage tank ccccceeeeeeeseeeeeeeeeeeeeeeeeeeeeeeeeeeeees 18 Installation Solar control unit cece eee 24 Installation Solar Collectors cc ee citi iii nn in nie 27 Connections Plumbing cccccceeeeeeeeeeeeeeeeeeeeeeeeeeeeeeaeeeeeeeeeeeeeeees 28 Connections Electrical ic scccsicecccecinecevesineceuevinecvectineseeevineseeetineseneniie 32 COMMISSIONING eis iaia ai pamaadaitmi detec edvisineedda ete daaraan idake i kraai 34 Draining the Solar collectors ccceecceeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeees 36 Draining the water heater cccceccceeeeeeeeeseeeeeeeeeeeeeeeeeaeeeeeeeeeees 36 Water Supplies si cviccesicceccsvaieceeccsttesstressasneassweceesesemnasestracsauecetsesiassasil 38 Warranty cect hich torreon Ginette eee 40 ABOUT YOUR WATER HEATER MODEL TYPE Congratulations for choosing a Rheem electric water heater and a Rheem solar conversion kit The Rheem solar conversion kit converts your Rheem electric water heater into a Rheem solar Loline water heater Your Rheem solar Loline water heater is designed for the solar col
46. ull of water and all of the hot taps are turned off e Using a flat blade screwdriver open I the bleed valve if it is not already air bleed open fitted adjacent to the 5 vvay tee valve at the cold vvater inlet of the vvater heater see diagram e The mains pressure will force water to flow from the tank and through the pipe work expelling air from the collector circuit through the bleed valve This is evidenced by spurting of water from the drain line connected to the bleed valve Warning Exercise caution as water may be at a very high temperature e Close the bleed valve when water runs freely from the drain line ABOUT YOUR WATER HEATER FLUSHING THE SOLAR COLLECTORS It may be necessary to flush the solar collectors if there is sediment in the water supply To flush the solar collectors follow the procedure Bleeding the Solar Collectors on page 7 allowing the water to flow from the bleed valve drain line for five minutes before closing the bleed valve It is recommended to flush the solar collectors every five years This will assist in keeping the solar collectors solar cold pipe and solar hot pipe clear of sediment FREEZE PROTECTION The system is suitable for installation and offers protection against freeze damage in areas up to 800 metres altitude The system is not covered for freeze damage above 800 metres altitude refer to Warranty on page 40 The anti freeze control is designed to recirculate a
47. water is up to 2500 mg L In areas where the TDS exceeds 600 mg L it is possible the black anode which is the standard anode fitted to the water heater may be excessively active To alleviate this the black anode should be replaced with one colour coded blue Where the TDS of the water is less than 40 mg L such as when the water has been deionised or is from an alpine supply a high potential anode colour coded green should be used The changing of anodes must be carried out by a plumber or authorised service person CAUTION If your water supply has a TDS greater than 600 mg L and the anode has not been changed to a blue one there is the possibility hydrogen gas could accumulate in the top of the water heater during long periods of no use If under these conditions the water heater has not been used for two or more weeks the following procedure should be carried out before using any electrical appliances automatic washing machines and dishwashers which are connected to the hot water supply The hydrogen which is highly flammable should be vented safely by opening a hot tap and allowing the water to flow There should be no smoking or naked flame near the tap whilst it is turned on Any hydrogen gas will be dissipated This is indicated by an unusual spurting of the water from the tap Once the water runs freely again any hydrogen in the system will have been released In areas where this is likely to occur the householder should be