1. GLX490 RM GALAXY HOOD GLASS Instructions Manual www rangemaster co uk Instructions Manual INDEX RECOMMENDATIONS AND SUGGESTIONS aicea ear iia tea au ette 3 CHARACTERISTICS INSTALLATION RECOMMENDATIONS AND SUGGESTIONS The Instructions for Use apply to several versions of this appliance Accord ingly you may find descriptions of individual features that do not apply to your specific appliance INSTALLATION The manufacturer will not be held liable for any damages resulting from incor rect or improper installation Check that the mains voltage corresponds to that indicated on the rating plate fixed to the inside ofthe hood For Class appliances check that the domestic power supply guarantees ade quate earthing Connect the extractor to the exhaust flue through a pipe of minimum diameter 120 mm The route of the flue must be as short as possible Do not connect the extractor hood to exhaust ducts carrying combustion fumes boilers fireplaces etc If the extractor is used in conjunction with non electrical appliances e g gas Dan tza Nu burning appliances a sufficient degree of aeration must be guaranteed in the CEN mm room in order to prevent the backflow of exhaust gas The kitchen must have an opening communicating directly with the open air in order to guarantee the entry of clean air USE The extractor hood has been designed exclusively for domestic use to elimi nate ki
2. Do not place the remote control near to heat sources e Used batteries must be disposed of in the proper REMOTE CONTROL OPTIONAL manner T1 Lighting Upper panel closed opens the upper panel and sets the lights at the maximum inten sity Upper panel open switches the lights on off T2 Courtesy light Sets the lights at an intermediate intensity or switches the lights off only when the upper panel is open T3 Motor Upper panel closed opens the upper panel switches on the motor at the latest se lected speed Upper panel open switches the motor on off When pressed for about 2 Seconds upper panel closed opens the upper panel and switches on the motor at the third speed and the lights at the maximum intensity Upper panel open switches off lights and motor and closes the upper panel T4 Decreases the speed at every short pressure When pressed for about 2 Seconds decreases the intensity of lights T5 Increases the speed at every short pressure When pressed for about 2 Seconds Increases the intensity of lights T6 Activates deactivates the intensive speed T7 Delay 24h Activates deactivates the Delay function When pressed for 2 seconds Activates deactivates the 24H function MAINTENANCE Metal grease filters Filters can be washed in the dish machine They need to be washed when Drop sign appears on the display or in an
3. e In order to align the hood it is necessary to adjust the Vr screws from inside the hood Fasten the safety screw 11 Fit again the metal filters into their seats and close the upper panel by pressing L key for one second see Part USE e Disconnect the hood from the mains supply Attention the upper panel stops if any barrier occurs in its way during the panel opening or closing To open the panel it is enough to remove the barrier and press the key once again Connections DUCTED VERSION AIR EXHAUST SYSTEM When installing the ducted version connect the hood to the chimney using either a flexible or rigid pipe 150 or 125 mm the choice of which is left to the installer To install a g 125 mm air exhaust connection insert the reducer flange 9 on the hood body air outlet and the adapting ring 8120 125 10 on the reducer flange e Fix the pipe in position using sufficient pipe clamps not supplied Remove any activated charcoal filters 11 ty v y 1 1 1 L Wr 1 I uw 1 1 1 raya nl 1 1 v 1 i A i _ a 9 RECYCLING VERSION AIR OUTLET To install the hood in recycling version the optional charcoal filter kit must be purchased Remove the chimney angle bracket e Screw the filter cover onto the air outlet using four screws 12c 2 9 x 12 5 Fix the air outlet grid 8 on the recirculation air outlet using the 2 screws 12d 2 9 x 9 5 provided
4. RECIRCULATION VERSION AIR OUTLET Insert the connection extension pieces laterally 14 1 in connec tion 15 e Insert the Connector 15 into the Support bracket 7 3 and fix it with a screw Make sure that the outlet of the extension pieces 14 1 is hori zontally and vertically aligned with the chimney outlets e Connect the air outlet connection 15 to the hood body outlet using either a flexible or rigid pipe 150 mm the choice of which is left to the installer Ensure that the activated charcoal filters have been inserted ELECTRICAL CONNECTION e Connect the hood to the mains supply Open the upper panel by pressing the A key See Part USE for at least 2 seconds e Remove the metal filters See Part MAINTENANCE and make sure that the connector piece of the supply cable is cor rectly inside the hood socket Flue assembly Upper exhaust flue Slightly widen the two sides of the upper flue and hook them behind the brackets 7 2 1 making sure that they are well seated Secure the sides to the brackets using the 4 screws 12c 2 9 x 9 5 supplied Make sure that the outlet of the extensions pieces is aligned with the chimney outlets Lower exhaust flue Slightly widen the two sides of the flue and hook them between the upper flue and the wall mak ing sure that they are well seated Fix the lower part laterally to the hood body using the 2 screws 12c 2 9 x 9 5 supplied
5. USE Control panel A B e D E ECG H 4 L OOOO O MMM OO DOC Key Function Display Upper panel closed when pressed for about one sec ond it opens the upper panel It switches the motor on at the latest selected speed Upper panel open when shortly pressed it switches the motor on off Indicates the selected speed Decreases the suction speed Number of lit LEDS decreases Increases the suction speed Number of lit LEDS increases Saja Functioning only when the upper panel is open This speed has been timed at 10 minutes After that time the system activates automatically the latest selected speed The function is suitable for cooking conditions when vapours and smells are of the utmost emission I flashes and all the LEDS on the display are lit By pressing the key the function is deacti vated Functioning only when the upper panel is open By pressing this key it is possible to set up the motor to a suction speed at 100 m h 24 symbol appears and the LEDS on the display go off cyclically one by one By pressing the key the function is deacti vated Functioning only when the motor is on By pressing this key it is possible to set the delayed shutdown of the motor and the lighting to 30 minutes A flashing clock symbol appears By pressing the key the function is deacti vated By pressing this key for about 2 seconds it is possible to reset the filter satu
6. d human health which could otherwise be caused by inappropriate waste handling of this product For more detailed information about recycling of this product please contact your local city office your household waste disposal service or the shop where you purchased the product CHARACTERISTICS Dimensions 19 9479 9 Sbll 9SLHUXVIA 9 S HL NIA Components Ref Q ty Productcomponents 1 1 Cooker hood with control unit lights blower unit filters 2 1 1 Upper chimney 2 2 1 Lower chimney 8 1 Airoutlet grid 9 1 Reducer flange 150 120 10 1 Adapting ring 120 125 mm 141 2 Air Outlet Connection Extension 15 1 Air Outlet Connection 16 1 Cover for recycling version Ref Q ty Installation components 7 2 1 2 Fixing brackets for upper chimney 73 1 Air Outlet Connection Support 11 7 Plugs lla 2 Plugs SB 12 10 12a 7 Screws 4 2 x 44 4 12c 10 Screws2 9x6 5 12e 2 Screws 2 9 x 9 5 Q ty Documentation 1 Instruction booklet 12a 721 M INSTALLATION Hood body mounting Firstly it is necessary to adjust the two Vr screws of the 11a brackets at minimun B Hang the hood body on the two brackets 11a e Connect the hood to the mains supply by means of a bipolar switch with at least 3 mm contact gap e Press the A key for one second see Part USE to open the upper panel Remove the metal filters
7. he same features Put the fuser holder and grease filters into their place again Make sure that the hood functions correctly In case the panel doesn t work correctly it is necessary to contact an authorized technician If the fuser gets damaged being the panel open it is suf ficient to simply remove the grease filters and replace the fuser RANGEmaster Clarence Street Royal Leamington Spa Warwickshire CV31 2AD England Tel 44 0 1926 457400 Fax 44 0 1926 450526 E mail consumers rangemaster co uk www rangemaster co uk AGA RANGEMASTER LTD 436004217_verl
8. ration alarm A drop symbol indicates that the metal grease filters saturation alarm has been activated and the filters need to be washed The alarm is triggered after 100 working hours C indicates that the charcoal filter satura tion alarm has been activated and the filter has to be replaced The alarm s triggered after 200 working hours By pressing this key the intensity of the lighting sys tem can be modified up to five levels Upper panel closed when pressed for about 1 second it opens the upper panel and sets the lights at the maximum intensity Upper panel open when shortly pressed it switches the lights on off Upper panel closed when pressed for about one sec ond it opens the upper panel and switches the motor on at the third speed and the lights at the maximum intensity Upper panel open when pressed for about 1 second it switches off motor and lights resetting every activated function and closes the upper panel Keyboard lock it is possible to jam the keyboard when for example cleaning the glass The motor and lights are switched off and upper panel can be open or closed By pressing the F key Delay for about 5 seconds the keyboard block can be activated or de activated This function is confirmed by a Beep and by moving motor LEDS on display The appliance can be controlled using a remote control powered by a 1 5 V carbon zinc alkaline batteries of the standard LRO3 AAA type
9. symbol lit charcoal filter saturation alarm ACTIVATED e C symbol unlit charcoal filter saturation alarm DEACTIVATED REPLACING THE CHARCOAL FILTER Alarm reset Press the G key for at least 2 seconds Replacing the filter e Open the upper panel by pressing the A key for about a second see Part USE e Remove the metal filters Remove the saturated charcoal filter as indicated A Fit the new filters as indicated B e Put the metal grease filters in their seats Lighting LIGHT REPLACEMENT 20 W halogen light Extract the lamp from the lamp holder by pulling gently e Replace with another of the same type making sure that the two pins are properly inserted in the lamp holder socket holes Replacing the fuser The hood panel opening and closing mechanism is con trolled by a starter motor which is activated by a fuser This fuser works only on the starter motor In case the fuser gets damaged when the panel is closed it is be necessary to manually unblock the panel In this case proceed as follows Remove the cover placed up on the left side Press the releasing lever with the screwdriver as much as necessary to enable the manual opening of the panel After having completely opened the panel remove the metal grease filters as explained in the part concern ing the filter cleaning The fuser is placed up on the right side Turn the fuser holder as indicated Replace the fuser with one having t
10. tchen smells Never use the hood for purposes other than for which it has been designed Never leave high naked flames under the hood when it is in operation Adjust the flame intensity to direct it onto the bottom of the pan only making sure that it does not engulf the sides Deep fat fryers must be continuously monitored during use overheated oil can burst into flames Do not flambe under the range hood risk of fire This appliance is not intended for use by persons including children with re duced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety Children should be supervised to ensure that they do not play with the appli ance MAINTENANCE e Switch off or unplug the appliance from the mains supply before carrying out any maintenance work Clean and or replace the Filters after the specified time period Clean the hood using a damp cloth and a neutral liquid detergent 2052698 The symbol X on the product or on its packaging indicates that this product may not be treated as household waste Instead it shall be handed over to the applicable collection point for the recycling of electrical and electronic equipment By ensuring this product is disposed of correctly you will help prevent potential negative consequences for the environment an
11. y case every 2 months or even more frequently in case of particularly intensive use of the hood Alarm reset Press the G key for at least 2 seconds Cleaning the filters Open the upper panel by pressing the A key for 1 second see Part USE e Remove the filters one by one pushing them towards the back side of the hood unit and simultaneously pulling downwards Any kind of bending of the filters has to be avoided when washing them Before fitting them again into the hood make sure that they are completely dry The colour of the filter sur face may change throughout the time but this has no influence to the filter efficiency e When fitting the filters into the hood pay attention that they are mounted in correct position the handle facing outwards Charcoal filter recycling version This filter cannot be washed or regenerated It must be replaced when the C appears on the display or at least once every 4 months The filter saturation alarm has to be activated already before Activation of the alarm signal In the recycling version hoods the filter saturation alarm must be activated during the instal lation or later e Switch off the hood and the lights Press the E key for about 5 seconds until the last two segments of the motor LEDS are lit on the display By releasing the E key the clock icon starts to flash e Within 3 seconds press the D key to activate deactivate charcoal filter saturation alarm e C
Download Pdf Manuals
Related Search
Related Contents
GSTM-2046 -2646 -3246 Spécifications Manuale installazione uso e manutenzione Installation, use and 1428_p01_FT_HC_ Plus_0.5_SR_ES_14-15 Evaluation CP mode d`emploi - Circonscription de Soisy ASH Samsung SPH-E3700 Bluetooth User Manual LXI690G Version PDF - Argenteuil GLX-RSS-2-100 GLX-RSS-2-300 ROZADORA CONSEJOS - MATILSA, alquiler I.E. Scuole Civate Copyright © All rights reserved.