1. Program Button QUANTUM ofe e SUAIN GROUP Figure 1 Board Layout b EUA TSE Selects between the onboard battery right or an external power source left For external power between 8 to 20 Volts DC Power should be free from switching noise and short term fluctuations for best performance A 9V battery is fine for short term use but make sure the battery does not drain to below 8V or erroneous operation can occur Provides communications between the QTM300CA and the PC It allows the user to upload or download setups from the cloning adapter to the target QT3xx The cable to the PC should be an extension type wired 1 1 included Connects to the target board and can be connected whether or not the target is powered The cable has a stripe on one side care should be taken not to reverse this cable This stripe aligns with pin 1 white square of the E3A or E3B board header The QTM300CA can be used to program QT3xx chips onboard The board can accom modate either a ZIF socket or a SMT socket when used with appropriate adapters not included see Figure 1 above and ZIF Info Page 11 In Stand alone mode once the chip to be programmed is inserted the QTM300CA will detect the chip part number and display it on the DEVO and DEV1 LEDs see below If a QT3xx chip has been auto detected this button will clone Setups data from the QTM300CA to the chip The PROG LED see next section indicate
2. a stand alone basis You can also read back these Setups to your PC at any time to verify them The QTM300CA can independently store three Setup configurations one for each part type Here s how Step 1 Hook everything up Connect the serial cable from the PC to the QTM300CA e Power up the QTM300CA s A target chip or board can be connected but in this process it will not be affected Step 2 Start QT3View on the PC e The PC LED should light up on the QTM300CA DEVO and DEV1 LEDs will flash to indicate no part found if no part is connected Step 3 Load Modify the Setups E E e Select the device tab in QT3View that you wish to work on e Load in a Setup file from disk if desired or Load in the Setups stored in the QTM300CA using the Download from Adapter button into the current tab Note the other tabs will not be affected e Enter the target operating voltage and burst length see page 6 if desired e Change the Setups in the current part tab using the dialog boxes if desired e Select a different device tab if you wish to work on another part type and repeat this Step 3 Step 4 Transfer the data to the QTM300CA s internal eeprom e Select the device tab which you want to upload to the QTM300CA e Upload the Setup contents from this tab to the QTM300CA using the Upload to Adapter button e QT3View will display the success or failure of the copy process in the Data Trans fer Status Display
3. for production Quick Start to begin using the board right away 1 Connect the QTM300CA to a PC using the serial cable included Make sure the serial port is not being used by any other application or driver 2 Connect the QTM300CA to the target board s 10 pin IDC cloning header the stripe of the cable connects to the pin marked with a white square 3 Run QT3View on the PC 4 Power up the target board and the QTM300CA QT3View will communicate with the QTM300CA and determine the specific QT3xx variant installed on the target board The appropriate tab for the detected part will appear on top To show the current Setups in the chip click the Sensor Download from Chip button see page 5 the Setups on the tab will be updated with what is in the chip It is now possible to change the Setups from the PC using the selector boxes The new Setups become effective as soon as you make the change and will operate the next time you power up the chip in its normal operating mode When you are done making changes unplug the cloning cable and reset the QT3xx chip to cause it to recalibrate and run properly Note The cloning adapter is tolerant of power sequencing it does not matter whether the cloning adapter or target is powered up or switched off first Z QUANTUM 2 QTM300CA R1 02 25 09 03 RESEARCH GROUP Board Details Power Switch Power Connector RS232 Connector Cloning Ribbon Cable IC Programming Socket
4. gI E iR 1 Te E u2 TP e q J2 A 4 BAV99 78LOSACZA vec vcc 100nF tin Trout Ht 2 Ta gt Min Vout T 10 train T20ut 2 Eure GND te 12 T y Los 1P2 sles sl le L Sk E D1 4 7uF GND 22uF R2in R2out 2 RS232 ao 25V 6 3V 2R f 7 J2 B Z QUANTUM 11 QTM300CA R1 02 25 09 03 RESEARCH GROUP AS QUANTUI ve Copyright 2003 QRG Ltd All rights reserved Patented and patents pending Corporate Headquarters 1 Mitchell Point Ensign Way Hamble SO31 4RF Great Britain Tel 44 0 23 8056 5600 Fax 44 0 23 8045 3939 admin qprox com www qprox com North America 651 Holiday Drive Bldg 5 300 Pittsburgh PA 15220 USA Tel 412 391 7367 Fax 412 291 1015 The specifications set out in this document are subject to change without notice All products sold and services supplied by QRG are subject to our Terms and Conditions of sale and supply of services which are available online at www qprox com and are supplied with every order acknowledgement QProx QTouch QMatrix QLevel and QSlide are trademarks of QRG QRG products are not suitable for medical including lifesaving equipment safety or mission critical applications or other similar purposes Except as expressly set out in QRG s Terms and Conditions no licenses to patents or other intellectual property of QRG express or implied are granted by QRG in connection with the sale of QRG products or provision of QRG services QRG will not be liable for customer prod
5. only Hardware Allows you to enter the expected chip supply voltage and the burst length total of both Parameter channels together in the case of the QT320 in order to allow Guideline boxes to show Entry reasonably accurate timing values The QTM300CA cannot measure these parameters To measure the burst length use an oscilloscope with a 750K series resistor on the probe tip to limit loading and measure on either SNS pin of the QT chip from the start of the first pulse to the end of the last QT320 Add together the burst length times of both channels when entering the number for this chip Status Bar The status bar at the bottom shows the serial port and connection status Display Possibilities are Serial Port Status Off Line COM1 57600 N 8 1 COM2 57600 N 8 1 Connection Status Status Clone connected Status Clone amp QT300 connected Status Clone amp QT310 connected Status Clone amp QT320 connected Status No Clone Z QUANTUM 6 QTM300CA R1 02 25 09 03 RESEARCH GROUP Cloning Directly to a Chip You can read and clone back information to a QT3xx chip directly from your PC without involving the onboard stand alone memory of the QTM300CA Here s how Step 1 Hook everything up Connect the serial cable from the PC to the QTM300CA e Connect the QTM300CA s cloning cable to the target PCB or plug a QT3xx into the onboard socket s Power up the QTM300CA and if necessary the target PCB Ste
6. QTM300CA USER S GUIDE Cloning Adapter for the QT3xx family of QProx ICs Description The QTM300CA is a cloning adapter designed to interface between any QT3xx 8 pin ipa sensor IC QT300 QT310 B QT320 and a PC or other host device This adapter permits the designer to upload settings from a PC into the target chip or to read the settings inside a chip The supplied cable allows the board to plug directly into both the E3A and E3B eval boards For production use the target PCB can have a similar connector which allows the QTM300CA to upload settings on a mass basis The cloning process takes under 1 second to complete The QTM300CA s eeprom memory permits the board to be used as a stand alone cloning adapter once it is programmed from a PC with the desired setups An onboard socket also allows the user to program QT3xx parts individually The QTM300CA can also be used to read back and verify the settings in QT3xx parts For the QT300 continuous IC this adapter also provides the additional functionality of interfacing to that device s SPI port to download signal data which can then be observed directly on the PC in real time using QT3View software QT3View PC software is included and updates can be downloaded from Quantum s web site You should find the following materials included with your QTM300CA Materials 1x QTM300CA board E 1x RS232 DB 9 serial extension cable Provided 1x RCO02 IDC to IDC clo
7. arnell co uk Logical Systems PA8SO1 2006 6 www logicalsys com Figure 4 QTM300CA Circuit Diagram VCC R19 lt SR20 lt R21 R22 SR23 lt R24 vec 4 7K gt 4 7K gt 4 7K gt 4 7K gt 4 7K gt 4 7K 4 7K ADA 7 03 c1 Y Bavoo us ale 1 gt 21 1648 1 Re C 100nF U1 312 15h 2 o o CA 3 nv o N j PIC16F873 XT1 514 15 12 4 e gs 20MHz S s 1 m CONI di 2 Rae Ano OSC1 CLKin 2 E 813 9 T y 7 VCC RA1 ANO 0SC2 CLKout 12 1 SOCKET16 gS RA2 AN2 e R15 vec 5 RA3 AN3 Vref RBot H2 1K 8 Ras TOCKI RB1 sSH22 J1 A Lz as S ZARAS AN4 55 R82 AN8 25 J1 B 2 RB3 AN9 LVDin 24 47K 47K E i rcosTiososTicki rea 25 y1 C 2 7 12 IRC1 T10SI CCP2 rs 26 J1 D L E 13 Jrcavccrt ree 22 JE paa RAN 14 Re3 SCK SCL np7L28 JF 6 ST 15 1RC4 SDI SDA vec J1 G El m Noa 16 IRc5 s00 Rc6 Tx ck 7 U4 Rr e J1 H e El Z rorexor H SP232A lis om S J 8 pam g foo c3 i ller Vee y4 2 J1 J He 3 Joi v i 19 S A N
8. at the left of the screen e Repeat Step 4 with other tabs if desired to copy over other part type Setups Cloning Setups from the QTM300CA to a Chip You can clone Setup information from the QTM300CA to a chip either on a target PCB or inserted into the onboard socket without the need fora PC The QTM300CA stores the Setup information in its onboard eeprom for use in cloning The three part types QT300 QT310 and QT320 each have their own page of Setups in the QTM300CA Here s how Step 1 Hook everything up e Connect the QTM300CA s cloning cable to the target PCB or insert a QT3xx chip into the onboard socket e Power up the QTM300CA and if necessary the target PCB s The DEV LEDs should indicate the correct part auto detected see page 4 Step 2 Clone the Setups to the Chip e Push the PROG button on the board The PROG LED will light to indicate programming status The PROG LED will flash to indicate the programming result see page 4 Z QUANTUM 8 QTM300CA R1 02 25 09 03 RESEARCH GROUP Clone Connector Design Rules Care must be taken when designing an onboard cloning connector The following are a few requirements needed for a successful cloning connector design QT320 QT310 Place the connector as close as possible to the chip Placing the cloning connector far from the part will increase sensor load capacitance Cx and decrease sensitivity as some of the cloning lines are also sense lines Long distances on c
9. loning lines can also make the clone process more susceptible to communication errors from ringing and interference and create an RF antenna for external fields QT310 If the Synchronization input is used a 10K resistor should be used to avoid problems with the cloning process see Figure 4 below Figure 3 QT300 Clone Connections Vdd Vdd Vdd Sf Y 8 E E Vcc DRDY TIGR SCK Z sck susi E Electrode REQ 6 REG s TS SDO 4 7 spo Vss s S aL Figure 4 QT310 Clone Connections BI QS S 5305 7 ICAL OUT 3 mee te gt ISYNC_ S QUANTUM 9 QTM300CA R1 02 25 09 03 Figure 5 QT320 Clone Connections GND SDI SCK Q Q n Vdd 3 Electrode 1 C 5 S1 OUT1 6 Electrode 2 OUT2 OUT2 S2A O n N S2B Z QUANTUM 10 QTM300CA R1 02 25 09 03 RESEARCH GROUP Table 1 Clone Cable Functional Pinout Usage by Part Pin QT300 QT310 Qr320_ pt Vvet Vet Ve 2 GND GND GND 3 DRDY Nne Ne 4 ne ne Ne po 5 Nc nce Ne 6 SDO SDO SDO 7 SDI REQ SDI SDI 1 cc Note 1 Vcc is connected via a 1K pullup on QTM300CA board Table 2 Chip ZIF Socket Order Information ZIF DIP Socket ZIF SMT Socket Web sites Digi key 3M1602 ND 309 1048 ND www digikey com Farnell 103 907 www f
10. ne cable RC01 IDC to 7 way for older E3B boards is available on request 1x 9V battery 1x QT3View user guide 1x CD Rom with QT3View software or download latest from www qprox com You will also need A PC running any recent version of Windows 98 98SE NT4 2000 XP upwards with a free serial port Com 1 or Com 2 and if desired a bench power supply to replace the battery 9 15V DC for long term use Z QUANTUM 1 QTM300CA R1 02 25 09 03 RESEARCH GROUP Overview The QTM300CA can operate in two basic modes PC driven mode Stand alone mode In PC driven mode you can a Load Setup information into it for all three part types for use in stand alone mode from a PC running QT3View b Communicate directly from the PC to the QT3xx part without disturbing the contents of the QTM300CA c Read back the Setups of any QT3xx device to your PC d View actual signal data on screen in real time QT300 only e Store many Setups files to disk and program your devices from them In Stand alone mode you can a Auto select which device QT300 or other will be cloned b Load Setups information stored in the QTM300CA to a QT3xx device for example in a production setting Which mode PC mode is entered automatically when a PC running QT3View software is connected to the QTM300CA If a PC is not connected or running QT3View the board defaults to Stand alone mode Use PC mode for development and Stand alone mode
11. p 2 Start QT3View on the PC s The PC LED should light up on the QTM300CA e DEVO and DEV1 LEDs will indicate the auto detected chip type see page 4 e QT3View will select the proper part tab on the screen Step 3 Load Modify your Setups Download the Setups from the chip to your screen using the Download from Chip button see right or Load in a Setups file from disk this will overwrite all three configuration tabs e Modify the Setups parameters as desired e Enter the correct target operating supply voltage see page 6 if necessary e Enter the total burst length see page 6 if necessary e Save the Setups to disk if desired saves all three tabs into one file Step 4 Clone the Setups to the chip e Upload Setups to the chip from the current tab using the Upload to Chip button see right e QT3View will display the success or failure of the clone process in the Data Transfer Status Display at the left of the screen the PROG LED does not work in this mode e Remove the chip and install another and repeat this Step 4 Or e Remove the clone cable and connect to another target PCB and repeat this Step 4 Refer to the device data sheet and the QT3View help file for more information on Setup issues Z QUANTUM 7 QTM300CA R1 02 25 09 03 RESEARCH GROUP Storing Setups into the QTM300CA You can save Setup information from the PC to the onboard eeprom of the QTM300CA for use in cloning of parts on
12. pe fia fs a Parone Sime Seg Entry oe Active High Low Active High Low 5 00 Outputs s g e 2 Hoggle T Toggle J Guideline Fast Integrator A Info Boxes Clone Version 3 Negative Drift 100 436 s level Positive Drift pe H sevel 39 Sleep Cycles fF l COM1 576001 81 Status Clone amp QT320 connected SS ad S Connection Status QT3View Operation Part Selector Allows you to view and communicate with the right part Any serial data transfer will Tabs File Open File Save Sensor CommPort Sensor Upload to Adapter Sensor Download from Adapter Sensor Upload to Chip Sensor Download from Chip QUANTUM ofe e SUAIN GROUP involve only the active tab The software will auto recognize the type of chip connected to the QTM300CA and choose the right tab for you If no chip is installed the tab can be manually selected to allow data transfers with the QTM300CA s onboard e prom Restores a config file saved by File Save All three part selector configurations tabs will be restored by this action Saves all three part selector configurations to disk in a single file to a file name of your choice Selects the desired PC serial port Com1 is selected by default when the software is first started if it is available Sends the Setups of the open tab to the QTM300CA s onboard e prom for use in later cloning Repeat this step with each selector tab opened in turn to upload Setu
13. ps for multiple part types Reads the Setups from the e prom of the QTM300CA into the currently open selector tab Only the data for the open tab is read Repeat this step with each tab open in turn to read in all the configurations stored in the QTM300CA Sends the Setups from the currently open selector tab directly to the e prom of a QT3xx chip Data stored in the QTM300CA is not affected by this opera tion The open tab must coincide with the connected chip type Reads the Setups directly from the e prom of a connected QT3xx chip into the corresponding selector tab Data stored in the QTM300CA is not affected by this operation 5 QTM300CA R1 02 25 09 03 Setup and These boxes show and modify the available Setups for the chosen chip Guideline Boxes _ S Timing related values have no meaningful unit of measure unless interpreted together with the device supply voltage and Sleep Cycles To aid in understanding the effects of these Setups Guideline boxes are used next to timing related Setups to give an estimate of the result in seconds Guideline boxes cannot be modified they only exist to inform you of the effects of the timing Setups Guideline numbers will change if Sleep Cycles Burst Length or Voltage are changed because QT3xx device timings vary with these things The QTM300CA and QT3View cannot directly measure the effects of Setup changes or supply voltage changes The numbers presented are reasonable estimates
14. s the programming result The QTM300CA can store three sources of data one for each part type The correct source will be used to program the detected part 3 QTM300CA R1 02 25 09 03 Status LEDs PC Indicates if QT3View software is communicating with the QTM300CA This LED will turn off five seconds after communications have stopped DEVO DEV1 Displays the chip type connected via the ribbon cable or in the onboard socket DEV1 DEVO Ez ar gt l Nome _ gt On aro Pp On amao On On QT320 PROG Indicates the programming status of the target chip in Stand alone mode The PROG LED will light during the cloning process in Stand alone mode Afterwards the LED will flash on off 3 times to indicate completion Fast flashing 0 1s between flashes the clone process was a success Slow flashing 1s between flashes the clone process failed If the QTM300CA is not in communication with QT3View software the PROG LED will flash on and off Z QUANTUM 4 QTM300CA R1 02 25 09 03 RESEARCH GROUP QT300CA Transfer Buttons Data Transfer __y gt Downloading Status Display Figure 2 QT3View Screen Direct Clone Buttons Part Selector Tabs Fie Sensor Help 0 97300 grap 97320 Uploading Ready O Sensorl p Sensor Setup Fail L Threshold le Courts Boxes Hysteresis ja Y Counts Integrator fro bursts 10 bursts Max on fia
15. uct design and customers are entirely responsible for their products and applications which incorporate QRG s products