1. 2 Event Messages Alarm Events E A1003 0016 Releasing Lock held too long by domain_ID Meaning A zone merge could not be completed in the acceptable time Action Check the status of the switch given by domain ID A1003 0017 Activation of zoneset by management server failed due to port port number out of range Meaning A zone member defined by domain ID and port was received within a management server AZSD command with a port number out of range Action Check the management server application zoning configuration to ensure zone members are properly configured A1003 001B Failing remote zoning configuration total zoneset limit would be exceeded Meaning The maximum number of zone sets allowed on the switch has been exceeded because of a zone merge Action Reduce the number of zone sets on the remote switch A1003 001C Failing remote zoning configuration total member limit would be exceeded Meaning The maximum number of zone members allowed on the switch has been exceeded because of a zone merge Action Reduce the number of zone members on the remote switch A1003 001D Failing remote zoning configuration total zones in zonesets limit would be exceeded Meaning The maximum number of zones allowed in all zone sets has been exceeded because of a zone merge Action Reduce the number of zones on the remote switch A1003 001F Failing remote zoning configuration member limit for zone zone nam
2. A1004 0026 Configured Domain ID domain D not available and Domain ID is locked on this switch Meaning An attempt was made to connect a switch to a fabric with a conflicting domain ID and the domain ID could not be reassigned Action Change the domain ID so that it is unique in the fabric or disable the domain ID lock so that the domain ID can be automatically reassigned A1004 0029 No Switch capable of being Principal Switch Reconfigure Principal Switch Priority Meaning An E_Port isolated because the principal priority on all switches is set to 254 Action Configure one of the switches to be the principal switch by changing the principal priority A1004 002B Port port_number not configured for E Port capability reconfigure to G GL to connect to remote switch Meaning An attempt was made by a remote switch to connect through a port that could not configure itself as an E Port Action Change the port type on the remote switch to G Port or GL Port A1004 002D Non interop Legacy switch setting prevents domain port zoning Meaning Zone members involving switches of other vendors cannot be defined by domain ID and port number when Interop Mode is disabled and Legacy Address Formatting is enabled Action Disable False the Legacy Address Formatting enable Interop Mode or reassign the zone members using a method other than domain ID and port number A1004 002F Request for Domain ID rejected WorldWi
3. Secondary CPU s latch is closed so now able to become Fault Tolerant Meaning The QLogic 9000 secondary CPU blade latch has been closed the switch is now fault tolerant Action None A1005 007D Canceling callhome edit mode as a result of a CPU switchover Meaning A CPU blade switchover occurred while a CallHome Edit session was open The CallHome Edit session was canceled Action Reopen the CallHome Edit session 2 30 59060 07 D 2 Event Messages Alarm Events ls A1005 0082 Blade fault FW_APP_FAIL Internal application failure Meaning Internal application failure Action Contact your authorized maintenance provider A1005 008E Blade fault FW_APP_PEER_FAULT Application declared error communicating with another CPU Meaning An application declared an error communicating with other CPU Action Contact your authorized maintenance provider A1005 0096 blade id Blade fault HW MP ACCESS CPUX The MP SPROM data accessed via CPUx is either inaccessible or invalid Meaning The maintenance panel SPROM data accessed through the specified CPU blade is either inaccessible or invalid Action Contact your authorized maintenance provider A1005 009B IPSec configuration error error description Meaning An error occurred while saving changes to an IP Security configuration None of the configuration modifications have been applied to the switch s active database Action Resolve any other IP Securit
4. 8400 0097 DNS lookup for host_name failed Meaning The specified host name was not found on the Domain Name System DNS server Verify that the host name is correct If so report the failed host name to your network administrator I 8600 0007 PortApp Port port number Cancelling Online Test Meaning The online test was canceled I 8600 001C Bring down TH port because its mapped TF port port number goes offline Meaning The state of a Transparent Host port has changed to Downed because the state of the specified active mapped Transparent Fabric port has changed to Offline I 8600 001D PortlD port fcid PortWWN port wwn logged into nameserver Meaning The device given by the port Fibre Channel address and port WWN has logged in to the name server I 8600 001E PortID port fcid PortWWN port wwn logged out of nameserver Meaning The device given by the port Fibre Channel address and port WWN has logged out of the name server 1 8600 001F SYNC ACQ Meaning The port identified in previous event messages has acquired synchronization with a connected device 1 8600 0020 SYNC LOSS Meaning The port identified in subsequent event messages has lost synchronization with a connected device I 8700 0002 EPort In Fabric Reconfiguration Meaning Changes to the switch configuration are in progress I 8700 0003 EPort Topology change switch with domain ID domain D joined the fabric Meaning
5. A switch with the given domain ID has joined the fabric 2 76 59060 07 D 2 Event Messages Informative Events A 1 8700 0004 EPort Port port_number Remote Switch World Wide Name WWN is switch WWN Meaning A switch with the given domain ID has been discovered on the given port I 8700 0005 EPort Port port number Inter Switch Link ISL Offline Meaning The specified E Port is offline possibly due to a loss of synchronization I 8700 0006 EPort Port port number Reinitializing port previously isolated for reason reason Meaning The E Port that previously isolated for the stated reason is now reinitializing 1 8700 0008 EPort Link State Record LSR aged out for domain ID domain_ D Meaning A record in the Link State Database LSDB is being aged out It will no longer be in the LSDB I 8700 000B EPort Hotreset prohibited fabric is busy Meaning A hot reset is not possible when configuration changes are being made anywhere in the fabric I 8700 000C EPort Hotreset prohibited fabric is busy Meaning A hot reset is not possible when configuration changes are being made anywhere in the fabric I 8F00 0006 Fabric Removed Meaning The user has removed a fabric from the application I 8F00 0007 Switch Added Meaning The application fabric discovery process has discovered a new switch in the fabric I 8F00 0008 Switch Removed Meaning The user has removed a s
6. Action Modify the switch configurations so that R A TOV or E D TOV values are the same A1004 0015 Eport Isolating due to Invalid Attach Meaning An E Port isolated because of invalid attachment Action Check for invalid attachment due to security or authentication incompatibility A1004 0020 R A TOV mismatch indicated Reconfigure to connect to remote switch Meaning An E Port isolated because the R A TOV timeout values on the two switches do not match Action Modify R A TOV so that it is the same on both switches The recommended value is 10 seconds A1004 0021 E D TOV mismatch indicated Reconfigure to connect to remote switch Meaning An E Port isolated because the E D TOV timeout values on the two switches do not match Action Modify E D TOV so that it is the same on both switches The recommended value is 2 seconds A1004 0023 Attempting to connect to switch with incompatible time out value configured R A TOV E D TOV Meaning An E Port isolated because the values for R A TOVorE D TOV are not the same on both switches Action Modify the switches so that the time out values are the same A1004 0024 Attempting to connect to switch that is in non interop mode Meaning An attempt was made to connect to a switch with a different value for Interop Mode Action Modify the Interop Mode values so that they are the same on both switches 2 16 59060 07 D 2 Event Messages Alarm Events TO aaa
7. Configured port type is not compatible with the type of media installed Action Check media to make sure it is the correct type of media for the configured port type If configured to Ethernet port type make sure Ethernet media installed 59060 07 D 2 51 2 Event Messages Alarm Events ee A6001 0001 cmon insufficient memory Meaning The Hotreset command has failed due to insufficient memory on the switch The switch has been returned to its state before the Hotreset command was entered Action If acceptable enter the Reset Switch command to reboot the switch Contact technical support if a non disruptive code load and activation is required A6001 0002 cmon blade failed NDCLA Meaning The Non Disruptive Code Load and Activation NDCLA has failed on this I O blade Action None A6001 0003 cmon switch failed NDCLA Meaning The Non Disruptive Code Load and Activation NDCLA has failed The switch has performed a hard reset Action None A6001 0004 cmon Blade was removed during NDCLA Meaning An I O blade was removed during the Non Disruptive Code Load and Activation NDCLA Action None A6001 0005 Secondary CPU firmware update in progress hotreset aborted Meaning The firmware image was being updated on the secondary CPU when a hot reset was attempted Action Wait for the firmware update to complete then retry the hot reset 2 52 59060 07 D 2 Event Messages Critical Even
8. Switch User account_name attempted to log into switch with an incorrect password Meaning Invalid user login attempt C 8400 002E Switch number of zone members zone members are being saved this may take several seconds Meaning It will take several seconds to save the large zoning database C 8400 002F Switch Zoning database of over 3000 zone members may damage some vendors switches if you have other vendor s switches in your fabric please refer to their switch manual documentation to see what zone member limits the switch supports Meaning You have a large database on the switch consisting of over 3000 zone members This could cause a problem in mixed fabrics because not all vendors support a configuration this large C 8400 0030 Switch Zoning edit session has been preempted by a zoning merge Meaning A zoning edit session has been preempted by a zone merge The zoning edit session has been canceled C 8400 003B Switch Creating the support file this will take several seconds Meaning The switch is creating a support file This takes a few seconds to complete C 8400 003C Switch Network setup is changing may lose connection admin being released automatically Meaning Changes made to the network configuration may interrupt your connection to the switch C 8400 0042 Switch Warning deleting the active zoneset may cause fabric isolation Meaning Deleting the active zone set f
9. User SFC received with unknown operation operation code Meaning Received a frame from another switch with an unknown Staged Fabric Configuration SFC operation code Ignoring operation W 8300 0013 User Unlock failed resource unavailable will retry Meaning A fabric unlock performed through a Release Change Authorization failed because the switch ran out of buffer memory The unlock mechanism will retry when memory is freed up W 8300 0014 User Bad release change authorization response received from switch with domain ID domain D Meaning The switch is attempting to do a fabric unlock through a Release Change Authorization request but a remote switch indicated a failure This switch will proceed with the unlock W 8300 0015 User No RCA response received from domain D proceeding with unlock Meaning The switch never received a reply to a message sent to release the change authorization The release of the change authorization will occur regardless W 8300 0016 User Zoning activation failed resource limitation Meaning This switch is attempting to activate a zone set but cannot do so due to a resource problem W 8400 0007 Switch Attempted unauthenticated login username account name Meaning A login was attempted with an account name that was not in the list of allowable users of switch management 59060 07 D 2 67 2 Event Messages Warning Events EE W 8400 0018 Switch User accou
10. You can configure port alarm thresholds for the following port events using Enterprise Fabric Suite or the CLI 59060 07 D Cyclic Redundancy Check CRC errors Decode errors Inter switch Link ISL connections Device logins Device logouts Loss of signal errors To configure port threshold alarms using Enterprise Fabric Suite do the following 1 Open the Switch menu in the faceplate display and select Port Threshold Alarm Configuration The Port Threshold Alarm Configuration dialog prompts you to enable or disable all alarms select an event set triggers set a sample window and enable or disable an individual alarm For more information refer to the Enterprise Fabric Suite User Guide for your switch To configure port threshold alarms using the command line interface use the Set Config Threshold command For more information refer to the Command Line Interface Guide for your switch 1 5 1 Events and Event Logging Configuring Port Alarm Thresholds EE Se 1 6 59060 07 D 2 Event Messages This section lists event messages from the command line interface and Enterprise Fabric Suite in message ID sequence by the following severity levels Fault Events Alarm Events Critical Events Warning Events Informative Events You can look up a message by its message ID or by searching for the message text If the message you are looking for does not appear in this section contact your authorized maintenance provid
11. ji 59060 07 D 59060 07 D Table of Contents Preface Intended Au dlence uvae dac dre ARAM aca eda cha RA CR RC caca ds V Related Materials i pss 2s nues ben bdo ed runs bc PRX Cx EDO E aci es Documentation Conventions n aaa aaa aaaea eeann V Technical Support is du RR CREER ORC OR GR kee Ges hae Se was vii Traing a wr C PE EDI ERR OE LAORE eed saved RR d vii Contact Information llle vii Knowledge Base c sdsueseroobeerkRYeRe ee ERE ES oho OG ex viii Events and Event Logging Understanding Severity Levels llli 1 1 Displaying Events using the Event Browser 2000 eee eee 1 2 Displaying the Events Using the Command Line Interface 1 2 Configuring the Event Log 0 0 cece eee ee 1 4 Archiving and Downloading the Event Log cece eee eee 1 4 Configuring Port Alarm Thresholds 000 0c eee e eee eee 1 5 Event Messages Fault EV GMS amp 2026 ded x ed e ee oe Keane eee Ree eee des 2 1 Alarmi EVGWS 3 333 3729 ados 303 see ee eee eset Ed ned hd a e aS 2 4 Gritical ENSIS sesse sr YR RU RE RERHEDUDRREE MORE EU ERRSSMEBEER PR 2 53 Warning Events uem quoe cette ce ER teases RR dod o ol Bas e a uc ed 2 67 Informative Events 22223 vERLASRASTETEIARSSPRRERGSLPSRSedO C64 xS 2 72 Ill Reference Guide Fibre Channel Event Message QLogic 3000 5000 9000 Series Fibre Channel Switch EE ee iv 59060 07 D Preface This manual describes the alarm m
12. may lose connection admin being released automatically Meaning The Services configuration is changing and this may result in the loss of a connection C 8400 004D Switch ntpdate no server suitable for synchronization found Meaning The Network Time Protocol NTP server was not found C 8400 004E Switch ntpdate synchronization lost Meaning The Network Time Protocol NTP server synchronization was lost C 8400 0050 Switch Upgrading License allowing manufacturing setup mode capability Meaning The license upgrade was successful C 8400 0052 Switch Upgrading License for EFCM capability Meaning The license upgrade was successful 59060 07 D 2 57 2 Event Messages Critical Events ee C 8400 0053 Switch The switch WWN is being upgraded Meaning The license upgrade was successful C 8400 0054 Switch radius All RADIUS servers failed to respond Meaning None of the Remote Authentication Dial In Service RADIUS servers configured responded Check the RADIUS server configuration C 8400 0057 Switch User login user_name is being closed Telnet connections have been disabled Meaning A Telnet session has closed C 8400 0058 Switch User user name is using their initial default password Meaning The specified user has not changed their password from its initial value C 8400 005B Switch A nicknames configuration edit session has been canceled
13. temperature range Action None 59060 07 D 2 47 2 Event Messages Alarm Events EENNNNNM A3003 0001 IOn Hardware error detected Use show switch for more info Meaning A fatal hardware error was discovered during the Power On Self Test POST phase of startup This switch is not currently operational Action Enter the Show Post Log command to investigate A3003 0002 POST detected a fatal error the last time it ran and will be re executed Meaning A fatal hardware error was discovered from the previous Power On Self Test POST This switch is not currently operational Action Enter the Show Post Log command to investigate A3003 0003 Diagnostics have detected a fatal error on the I O blade in slot s ot number The blade is not operational Meaning Diagnostic testing has determined that there is a failure on specified I O blade The blade did not pass the Power On Self Test POST Action Enter the Show Post Log command to investigate A3004 0001 Non fatal hardware error detected Use show post log for more info Meaning A non fatal hardware error was discovered during the Power On Self Test POST phase of startup Action Enter the Show Post Log command to investigate A3004 0002 Diagnostics have detected a partial failure on the I O blade in slot slot number Meaning Diagnostic testing has determined that there is a partial failure on specified I O blade Most likely at least one
14. 07 D 2 71 2 Event Messages Informative Events amp Y O Ow Informative Events Informative events are events that occur in the normal activities of a fabric The following lists the event ID and text of the message along with an explanation of the message I 8200 0001 mserver Hotreset is not permitted at this time try again later Meaning The switch was busy at the time of the attempted hot reset Try the hot reset again later I 8200 0002 mserver Port port number Rejecting request from address FC address inband management is disabled on port port number Meaning A Management Server command was received on a port that is configured to refuse inband management requests I 8200 0100 mserver Cannot map number of characters characters to Switch Symbolic Name max number of characters Meaning The RIELN management server command was processed and the Interconnect Element Logical Name was registered However the registered name is of greater length than the maximum length allowed for the Switch Symbolic Name so therefore the Switch Symbolic Name was not changed to match the registered name I 8200 0101 mserver Cannot map non printable characters to Switch Symbolic Name Meaning The RIELN management server command was processed and the Interconnect Element Logical Name was registered However the registered name contains unprintable characters These characters are not allow
15. Action Purchase and install the Fabric Security license to continue using the security feature A1005 004B The switch was reset due to firmware upgrade issues Meaning After a firmware upgrade the Serial Prom Cyclic Redundancy Check CRC did not match what was expected It is likely that licenses were updated on the switch while running older firmware Action Check your license configuration for changes A1005 004C ICCnumber cable installed ALARM CLEARED Meaning A HyperStack cable has been connected to the specified Inter Chassis Connection ICC port and the associated alarm has been cleared Action None A1005 004D ICCnumber cable not installed ALARM SET Meaning A HyperStack cable is not connected to the specified Inter Chassis Connection ICC port and the associated alarm has been set Action None 2 24 59060 07 D 2 Event Messages Alarm Events A M A1005 004E Attempts to login backend switch fail because backend switch does not support NPIV Meaning The backend fabric switch does not support N_Port ID Virtualization NPIV which in turn brings down the TF_Port Action Ensure that the backend fabric switch supports NPIV A1005 004F Media device sensor is value units Transitioning from state to state Meaning The specified sensor temperature voltage TxBias TxPower RxPower has set a fault The sensor reports its value Celsius volts milli amp mps milliWatts and transit
16. HyperStacking must have two CPU blades to make use of the HyperStack feature If only one CPU blade is installed this alarm message is issued with alarm status ALARM SET When the second CPU blade is installed the alarm message is reissued with alarm status ALARM CLEAR Action If the alarm status is ALARM SET install the second CPU blade A1005 0068 Primary blade seating is questionable Meaning The QLogic 9000 primary CPU blade is not fully installed Action Reseat the primary CPU blade A1005 0069 Primary blade seating was resolved Meaning The QLogic 9000 primary CPU blade seating problem has been corrected Action None A1005 006A User account account name has expired Meaning The named user account has exceeded its expiration date Action Review the user account and make the necessary corrections A1005 006B Temperature too high turning off lasers Meaning The switch has overheated and the Fibre Channel port lasers have been turned off Action Power down the switch correct the conditions that caused the switch to overheat and power up the switch A1005 006C 3 3V out of spec turning off lasers Meaning Fibre Channel switch ports are receiving incorrect voltages Lasers have been turned off Action Contact your authorized maintenance provider 2 28 59060 07 D 2 Event Messages Alarm Events ls A1005 006D Unable to synchronize with NTP server Meaning The switch was unable to
17. Meaning A nicknames edit session was canceled by the user C 8400 005C Switch The switch will be reset in several seconds due to switch mode transition Meaning The configuration is changing between transparent mode and full fabric mode This will result in an automatic switch reset to activate the change C 8400 005D Switch Upgrading License for SANdoctor Meaning The SANdoctor bundle license was applied successfully C 8400 005E Switch Upgrading License for Transparent Switch Mode change capability Meaning The Transparent Mode license was applied successfully C 8400 005F Switch Upgrading License for SMI S capability Meaning The Common Information Model CIM license was applied successfully C 8400 0060 Switch Warning Illegal transparent mode configuration primary and backup cannot be mapped to the same port Port port number s backup mapping has been deleted Meaning When mapping TH ports to TF ports the primary and backup TF ports cannot be the same for a given TH port 2 58 59060 07 D 2 Event Messages Critical Events TE MM C 8400 0061 Switch Warning lllegal transparent mode configuration Either the primary or backup map for port port number was set to a port whose type is not TF The mapping for this port has been cleared Meaning An attempt was made to map a TH port to a port that was not of type TF C 8400 0062 Switch New firmware has been installe
18. QLogic logo QuickTools and Enterprise Fabric Suite are trademarks or registered trademarks of QLogic Corporation IBM and BladeCenter are registered trademarks of International Business Machines Corporation All other brand and product names are trademarks or registered trademarks of their respective owners Information supplied by QLogic Corporation is believed to be accurate and reliable QLogic Corporation assumes no responsibility for any errors in this brochure QLogic Corporation reserves the right without notice to make changes in product design or specifications
19. The E Port cannot exchange switch capabilities with the remote switch C 8700 0012 Eport Port port number Connection failure fabric limited to two switches Meaning The switch cannot be connected to the fabric due to a license restriction C 8700 0013 Connection failure fabric limited to two switches Meaning The switch cannot be connected to the fabric due to license restriction C 8B00 0005 Unable to test profile profile because the CallHome service is disabled Meaning The test of the named profile failed because the Call Home service is disabled C 8B00 0006 Unable to test profile because the CallHome service is disabled Meaning The test of the named profile failed because the Simple Mail Transfer Protocol SMTP server IP addresses are the factory defaults or the servers are disabled in the Call Home service configuration C 8B00 0007 Unable to test profile profile because the FromEmailAddress has not been configured in the CallHome setup Meaning The test of the named profile failed because the FromEmailAddress was not specified in the Call Home service configuration C 8B00 0008 Unable to test profile profile because the CallHome service is updating configuration Meaning The profile cannot be tested while the Call Home service configuration is being updated C 8B00 0009 Unable to send test result for profile profile Meaning The pass or fail notification for the test coul
20. W 8B00 0011 SMTP addresses are defaults or disabled will not retry sending messages until a valid SMTP address has been configured and enabled Meaning Either both Simple Mail Transfer Protocol SMTP server IP addresses in the Call Home service configuration are the default value 0 0 0 0 or they have not been enabled W 8B00 0013 Encountered failure communicating with SMTP server ip_address portzport number Reason reason Descriptionzdescription Response response Meaning The Call Home Simple Mail Transfer Protocol SMTP client was unable to establish communications with the specified SMTP server The Reason Description and Response fields describe the error If the error is a system call failure the Description field provides more detail If the error was an SMTP server response failure the Response field provides more detail W 8B00 0015 Profile profile recipient email_address via SMTP server ip address port number SMTP error error Meaning A Simple Mail Transfer Protocol SMTP error has occurred for the given profile recipient server and port W 8B00 0017 CallHome message send for profile profile to recipient email_address failed on SMTP server jp adaress port port number Retry will be attempted Meaning The Call Home service failed to send an e mail message to the recipient in the named profile through the specified Simple Mail Transfer Protocol SMTP server because of a transient error T
21. and QuickTools event browser can contain a maximum of 10 000 event messages Once the maximum is reached the event list wraps and the oldest events in the event list are deleted Event browser entries from the switch use the switch time stamp Event browser entries from Enterprise Fabric Suite and QuickTools use the management station and workstation time stamps respectively You can filter and sort the contents of both event browsers The Event Browser begins recording when enabled and Enterprise Fabric Suite or QuickTools is running If the Event Browser is enabled using the Preferences dialog the next time Enterprise Fabric Suite or QuickTools is started all events from the switch log will be displayed If the Event Browser is disabled when Enterprise Fabric Suite or QuickTools is started and later enabled only those events from the time the Event Browser was enabled and forward will be displayed Displaying the Events Using the Command Line Interface When you log into a switch through Telnet the command line interface automatically displays the alarm history You can use the Show Alarm or Show Log command to display the alarm history at any time New alarm messages are displayed in the command stream as they occur 1 2 59060 07 D 1 Events and Event Logging Displaying the Events Using the Command Line Interface TO OOM In the CLI each message has the following format ordinal time_stamp severity source message_
22. any recipients from profile profile Email message will not be sent for this profile Meaning The Simple Mail Transfer Protocol SMTP server does not recognize or could not resolve any of the recipient e mail addresses listed for the profile C 8F00 000C Fabric Status status Meaning The severity level of the fabric status has changed The description field will show the reason for fabric status C 8F00 000D Switch Status status Meaning The severity level of the switch status has changed The description field will show the reason for the switch status 59060 07 D 2 65 2 Event Messages Critical Events E e C 8F00 000E Link Status status Meaning The severity level of the link status has changed The description field will show the reason for the link status 2 66 59060 07 D 2 Event Messages Warning Events T EE EECESEUIII Warning Events Warning events are generally not disruptive but are more significant than Informative level events The following lists the Warning events and the event ID number and message displayed and provides an explanation of the message W 8300 0000 User Releasing Lock held too long by account name Meaning A lock was held by a user for too long The lock will be automatically released W 8300 0011 User Releasing Lock held too long by domain D Meaning A lock was held by another switch for too long The lock will be automatically released W 8300 0012
23. correctly there may be a resource problem on the switch Action If this is a recurring message contact your authorized maintenance provider A1005 0040 Unsupported SFP within port Meaning An unsupported SFP transceiver was installed in the port Action Replace the transceiver A1005 0041 Setting port admin state DOWN due to POST failure Meaning The port failed the power on self test and has been disabled Action Contact your authorized maintenance provider 59060 07 D 2 23 2 Event Messages Alarm Events E G A1005 0042 Target device port_address attached to port port_number with lOStreamGuard Enabled Meaning The target device is attached to a port with IO StreamGuard enabled Action Disable I O StreamGuard on the port A1005 0045 Configured port data conflicting within hardware capabilities Meaning Configured port settings conflict with the hardware capabilities of the port The port is down Action Reconfigure the port to be compatible with the port hardware A1005 0047 Attempts to login backend switch fail because backend switch does not support NPIV Meaning The backend fabric switch does not support N Port ID Virtualization NPIV which in turn brings down the TF Port Action Ensure that the backend fabric switch supports NPIV A1005 004A Temporary license for Fabric Security will expire in hours hour s Meaning The temporary Fabric Security license will expire in the time displayed
24. fabric disabling Transparent Routing on this port check ISL configuration reset port to retry Meaning The switch connected to the TR Port is part of the local fabric Action Remove the switch attached to the TR Port from the local fabric or disconnect the TR Port transparent routing is not needed to reach devices in the local fabric A1005 0112 PLOGI S ID fc id D ID fc jid OX ID ox id rejected during NDCLA Meaning A port login PLOGI was received for transparent routing after the Non Disruptive Code Load and Activation NDCLA had begun An attempt was made to send a reject Action Retry the port login after the NDCLA is complete 59060 07 D 2 33 2 Event Messages Alarm Events G A1005 0113 TR Port removing Proxy for port_wwn logged in at FC ID fc_id duplicate port name logged in at FC ID fc_id Meaning Action A device is logged in on another switch in the local fabric with the same port WWN as a proxy for a device in a remote fabric The proxy created on the local switch has been removed Examine the adapters with the given WWN and determine which is using the incorrect world wide name A1005 0115 DCBX TOO MANY NEIGHBORS error Policy policy name reason Meaning Action LLDP found too many neighbors on link DCBX is disabled DCBX is expected to run operate over a point to point link LLDP has detected multiple neighbors so DCBX will operate as if no DCBX peers are present until t
25. has been inserted into the chassis C 8400 0014 Switch IOn FC4G16 Blade was removed Meaning An I O blade has been removed from the chassis C 8400 0014 Switch CPUn CPU Blade was removed Meaning A CPU blade has been removed from the chassis C 8400 0015 Switch The switch will be reset in several seconds Meaning The switch is being reset as a result of a command from a user interface C 8400 0016 Switch Group members are being saved this may take several seconds Meaning Group members are being saved in the security database C 8400 0017 Switch Security edit session has been preempted by a security merge Meaning A security merge has occurred and the security edit session has been cancelled C 8400 001C Switch The switch is being reset this may take several seconds Meaning The switch is being reset C 8400 001D Switch The switch is being shutdown this may take several seconds Meaning The switch is being shutdown C 8400 0027 Switch Invalid user account name attempted to log into switch Meaning Invalid user login attempt C 8400 0028 Switch Invalid user account name attempted to log into switch Meaning Invalid user login attempt 59060 07 D 2 55 2 Event Messages Critical Events E a C 8400 0029 Switch User account_name attempted to log into switch with an incorrect password Meaning Invalid user login attempt C 8400 002A
26. set name merge conflict Meaning Action In non interop mode there is a conflict in the zoning configuration causing the Inter Switch Link ISL to isolate After a zone merge with interop mode disabled two zone sets were discovered in the local zoning database with the same name but different membership Contact your authorized maintenance provider A1003 0013 Segmenting zone zone name merge conflict Meaning Action In non interop mode there is a conflict in the zoning configuration causing the Inter Switch Link ISL to isolate After a zone merge with interop mode disabled two zone were discovered in the local zoning database with the same name but different membership Contact your authorized maintenance provider A1003 0014 Segmenting alias a ias name merge conflict Meaning Action There is a conflict in the zoning configuration causing the Inter Switch Link ISL to isolate Two aliases with the same name but different membership were discovered in the local zoning database Reconcile the active zone sets so that the two aliases have identical membership A1003 0015 Zoneset Activation received from switch with domain domain D failed unknown zoneset zone set name Meaning Action 59060 07 D A zone set activation received from the named switch failed because the zone set was not in the zoning database Examine the named switch to verify that the zoning database is correct
27. switch Meaning The zone merge failed Action See the switch log for more details on why the merge failed 2 8 59060 07 D 2 Event Messages Alarm Events ls A1003 0031 Error reading zoneset from activate direct Meaning Action A device supporting the management server has sent an Activate Zoneset Direct AZSD command that did not follow the expected standard layout Contact your authorized maintenance provider A1003 0032 Zoneset zone set name failed validity checks empty or contains empty zone alias Meaning Action The zone set either has no zones or contains a zone or alias without members Add zones and members or remove the empty zones and aliases from the zone set A1003 0033 No memory for command completion Meaning Action Insufficient switch memory Contact your authorized maintenance provider A1003 0034 Merge failed total zoneset limit would be exceeded Meaning Action A fabric merge failed because the combined number of zone sets exceeds the zoning database limit Remove zone sets from the local switch zoning database to allow the fabric merge to complete A1003 0035 Merge failed invalid zone data received ISOLATING Meaning Action A remote switch sent a zone merge that was invalid Reconcile interoperability modes on the local and remote switches so that they are the same A1003 0036 Merge failed member limit for zone zone name exce
28. transferring from the primary CPU blade to the secondary CPU blade on a QLogic 9000 switch Action None A2004 0003 Secondary cpu blade assuming control of system due to an opening of the latch or removal of Primary cpu blade Meaning Control is transferring from the primary CPU blade to the secondary CPU blade on a QLogic 9000 switch Action None A3000 0001 Temp overheat sensor name sensor reads value C ALARM SET Meaning The chassis temperature has reached a failure threshold Action Check air flow fan operation and ambient temperature If the problem cannot be corrected power down the switch A3000 0002 Temp sensor sensor name on blade s ot number reads value C ALARM SET Meaning The chassis temperature has reached a failure threshold Action Check air flow fan operation and ambient temperature If the problem cannot be corrected power down the switch A3001 0001 Temp overwarm sensor name sensor reads value C ALARM SET Meaning The chassis temperature has reached a warning threshold Action Check air flow fan operation and ambient temperature A3002 0001 sensor name sensor has returned to normal range ALARM CLEARED Meaning The chassis temperature has returned to the normal range and the alarm condition has been cleared Action None A3002 0002 Temp sensor sensor name on blade s ot number reads value C ALARM CLEARED Meaning The named blade has returned to the normal operating
29. type or members ISOLATING Meaning A fabric merge failed because two zones of the same name in two zone sets of the same name have different membership Action Reconcile the membership in the two zones so that they are the same A1003 003B Incomplete merge request sequence received unable to process request Meaning A remote switch sent a merge request that was not understood Action Check the remote switch for configuration errors or equipment malfunction A1003 003C Incompatible Zoning mode Isolating link Meaning The fabric contains switches with a mix of interoperability mode settings Action Configure all switches in the fabric to have the same value for interoperability mode A1003 003E Security Ports downed for INVALID ATTACH require administrative action to be brought online Meaning When deactivating a security set ports that were previously downed due to security violations remain down Action Reset the ports or place the ports online A1003 003F ISL group empty and links up Set ports offline to activate Meaning An attempt to activate fabric binding with an ISL group that has no members is not allowed because there are inter switch links ISL logged in to the switch Action Configure all ISLs offline or add each ISL member with fabric binding information to the ISL group before activating 2 10 59060 07 D 2 Event Messages Alarm Events ls A1003 0040 Zone Member type me
30. versions and licensing on the remote switch are compatible Otherwise contact your authorized maintenance provider A1004 0035 Failed to connect to a switch due to incompatibility check interop settings Meaning The remote switch failed to connect possibly because the interoperability mode setting is different from that of the local switch Action Reconcile the interoperability mode settings on the local and remote switch so that they are the same If necessary contact your authorized maintenance provider A1004 0036 Domain ID domain D assigned to different switches Cannot join fabrics Meaning An attempt was made to join two fabrics that had switches with the same domain ID Action Change the domain ID on one of the switches so that it is unique and then join the fabrics again A1004 0037 Fabric Binding Error please reconfigure Local switch assigned domain domain ID which is locked fabric binding indicates domain domain D should be used Meaning The local switch has a conflicting domain ID and cannot be automatically reassigned because the domain ID is locked Action Change the domain ID of the local switch 2 18 59060 07 D 2 Event Messages Alarm Events TO SSA A1004 0038 WorldWide Name WWN device_WWN assigned domain domain_ D fabric binding indicates this domain is reserved for device_WWN Meaning The user activated fabric binding conflicts with the current domain ID assignme
31. while processing the specified peer in a saved IKE configuration None of the configuration modifications have been applied to the switch s active database Action Correct the configuration and save it 2 32 59060 07 D 2 Event Messages Alarm Events ls A1005 010C IPSec configuration error IKE Policy policy_name error_description Meaning An error occurred while processing the specified policy in a saved IKE configuration None of the configuration modifications have been applied to the switch s active database Action Correct the configuration and save it A1005 010E TR Proxy Login for port_wwn failed native device with FC ID fc_idis alsoa proxy Meaning A transparent route attempted to map a device in the local fabric that is also proxy of a device in a remote fabric Action Physically move the device from the remote fabric to the local fabric A1005 010F PLOGI S ID fc ia D ID fc id OX ID ox id no proxy for destination device on this port Meaning A Port Login PLOGI could not be translated because no proxy was found for the destination address Action Contact your authorized maintenance provider A1005 0110 PLOGI S ID fc id D ID fc id OX ID ox id no proxy for source device on this port Meaning A Port Login PLOGI could not be translated because no proxy was found for the source address Action Contact your authorized maintenance provider A1005 0111 TR Port Name port wwn found in local
32. with domain ID domain_ID Meaning A Update Fabric Configuration UFC frame was sent to the switch given by domain_ID but a response was not received Action Check the status of the switch A1003 002C Zone Merge response indicates failure due to zoning limits Isolating link Meaning Response from other switch indicates that the active zone sets could not be merged Action Edit or delete the conflicting zone objects or deactivate the zone set on the remote switch A1003 002D Zone Merge response indicates failure to merge Isolating link Meaning The attempt to merge two fabrics failed because each active zone set contained a zone with the same name but different membership Action Edit the affected zone to remove the conflict or deactivate one of the zone sets A1003 002E Zoning merge has been rejected Meaning The attempt to merge two fabrics failed because the active zone sets each contained a zone with the same name but different membership Action Either edit the affected zone to remove the conflict or deactivate one of the zone sets A1003 002F SW2 Zoning Not Supported by other switch Isolating link Meaning The inter switch link isolated because the local switch is configured for FC SW 2 compliant zoning interoperability mode set to Standard but the remote switch is not Action Set the interoperability mode on the remote switch to Standard A1003 0030 Zone Merge rejected by remote
33. worldwide name within the ISL group to the current value of the domain ID A1003 0052 ISL group does not contain entry for switch domain D Meaning The ISL group does not contain an entry for each switch in the fabric Fabric binding requires an entry for each switch Action Make sure there is an entry in the ISL group for each switch in the fabric and try activating the security set again A1003 0053 Fabric binding must be unique domains are assigned to multiple security group members Meaning The fabric binding setting for the members of the ISL group are not unique Action Make the fabric binding settings unique for each member of the ISL group or set them to 0 so that they are not enforced A1003 0054 Failure at remote switch Meaning A frame was sent to a remote switch but the expected response was not received Action Check the status of the remote switch A1003 0055 Problem on zoning save of following switches domain D ist Meaning A zoning save could not be performed on some remote switches Action Examine the named switches If there are no obvious problems contact your authorized maintenance provider 2 12 59060 07 D 2 Event Messages Alarm Events TO EEE A1003 0058 Active ZoneSet zone set no longer in database please deactivate zoneset if not already in progress or fabric will be inconsistent Meaning A zone set with the same name as the current active zone set no longer r
34. 0039 Fabric Login FLOGI from address FC_address failed Meaning The payload of the FLOGI was not valid Action Check the device connection or replace the device If the problem persists contact your authorized maintenance provider A1005 003A Fabric Login FLOGI from address FC adaress failed authorization authentication Meaning Security authentication failed Action Check the security configuration on both the device and the switch to ensure that they are configured properly A1005 003B Warning Debug logging filter level is set Meaning Debug logging has been set using the Set Log Level command Action Confirm that you intended to do this If not use the Set Log Level command to change the severity level to Info Warn or Critical A1005 003C User Port s port numbers isolated lost steering path administering them to state DOWNED Meaning The ports required for steering the user ports have failed Action Contact your authorized maintenance provider A1005 003E Warning port s port numbers configured ONLINE but remain DOWN after NDCLA Meaning Ports that were down before a non disruptive code load and activation remain down This message serves as a reminder because the alarm log is cleared during the non disruptive code load and activation Action None A1005 003F Badly formatted SML Notification Ack session session D string string Meaning The switch sent a notification that was not formatted
35. 400 0079 Canceling config edit mode as a result of a CPU switchover Meaning A CPU blade switchover occurred while a Config Edit session was open C 8400 007A Resaving the zoning config as a result of a CPU switchover Meaning A CPU blade switchover occurred while saving the configured zoning database A save retry is occurring C 8400 007B Resaving the security config as a result of a CPU switchover Meaning A CPU blade switchover occurred while saving the security database A save retry will now occur C 8400 007C CPUn Switching over to Secondary blade D Meaning Control is transferring from the primary CPU to the specified secondary CPU blade 2 60 59060 07 D 2 Event Messages Critical Events TO EEE C 8400 007E b ade id Blade fault FW APP FAIL processing in progress gathering support information Meaning There has been an internal application failure on the specified blade C 8400 007F b ade id Blade fault FW APP FAIL processing in progress shutting down ports Meaning There has been an internal application failure on the specified blade the ports are shutting down C 8400 0080 Switch blade D Blade fault blade fault processing in progress gathering support information Meaning The system is gathering support information in response to the blade fault that occurred on the specified blade C 8400 008A A Zoning merge has occurred Meaning Two fabrics
36. 7 0012 Port with World Wide Name WWN port WWN address FC adaress not authorized to login verify MS security configuration Meaning The port cannot login with the current security configuration Action Add the named port to the Management Server group in the active security set A1007 0013 Response from address FC adaress lacks authentication discarding Meaning A response received on the indicated port lacked Common Transport CT authentication Action Verify that the CT security configuration of the management application using the remote port is compatible with the configuration of the Management Server security group on the switch A1007 0014 Response from WorldWide Name WWN device WWN address FC adaress failed authentication discarding Meaning A request received on the indicated port failed Common Transport CT authentication Action Verify that the CT security configuration of the management application using the remote port is compatible with the configuration of the Management Server security group on the switch 59060 07 D 2 39 2 Event Messages Alarm Events E A1007 001C Security Bad Authentication Flags Meaning The received AUTH frame did not meet the standard format for the frame payload Within the header portion of the payload there are some flags that are supposed to be set to zero 0 This frame has the flags set to something other than zero 0 Action Check the remote de
37. 9060 07 D 2 73 2 Event Messages Informative Events EE I 8400 0001 Switch Modifying configured DomainID domain_ID to negotiated value domain_ID Meaning The configuration is changing The configured domain ID is changed to the negotiated value 1 8400 0006 Switch Admin mode for user account_name was canceled by user account_name Meaning An Admin session was canceled by another user interface session that had the authority to do so 1 8400 001A Switch Admin access has timed out for user account_name Meaning The Admin session opened by the named user has timed out due to inactivity 1 8400 0022 Switch Successful login user account_name with admin privilege Meaning A user with admin authority has successfully logged into the switch The IP address of the user is unknown 1 8400 0023 Switch Successful login user account_name with admin privilege from address ip address Meaning A user with admin authority has successfully logged into the switch with the specified IP address 1 8400 0024 Switch Successful login user account name without admin privilege Meaning A user without admin authority has successfully logged into the switch The IP address of the user is unknown 1 8400 0025 Switch Successful login user account name without admin privilege Meaning A user without admin authority has successfully logged into the switch I 8400 0026 Switch A zoning configuration edit sess
38. Alarm Events TE MM A1005 011A DCBX PEER FEATURE ERROR error Policy policy name reason Meaning Action Peer on link has detected an error during DCBX Priority Group Priority Flow Control exchange An error has occurred during the configuration exchange of the specified feature The local and remote configurations are incompatible A1005 011C DCBX LINK DOWNED error Policy policy name reason Meaning Action The link has been downed by the DCBX protocol Consult additional alarms or logs for further information A1005 011D DCBX NO PER PRIORITY FLOW CONTROL error Policy policy name reason Meaning Action Peer specified no DCBX Priority Flow Control priority for FCoE traffic The peer Priority Flow Control feature TLV contained no enabled priority values DCBX cannot enable the link until a priority value is enabled A1005 011E DCBX MULTI PER PRIORITY FLOW CONTROL error Policy policy name reason Meaning Action Peer specified multiple DCBX Priority Flow Control priorities list of values The peer Priority Flow Control feature TLV contained multiple enabled priority values Only a single value is expected DCBX cannot enable the link until a single priority value is enabled A1005 011F ENODE MAC NOT CONFIGURED IN VLAN error Policy policy name reason Meaning Action An enode mac was not configured in list not responding to FIP request from host Configure
39. Correct the user authentication order or configure a RADIUS server A2000 0001 power supply number not installed ALARM SET Meaning The specified power supply blade has been removed or was not installed Action Install the power supply blade A2000 0002 power supply number failure ALARM SET Meaning The specified power supply blade has failed Action Contact your authorized maintenance provider A2000 0003 blade id Blade fault SENSOR FAULT Power supply blade reports an internal fault Meaning The specified Power Supply blade is reporting an internal fault Action Replace the Power Supply blade A2000 0004 blade id Blade fault AC FAULT AC power may be unplugged or switched off ALARM SET Meaning One of the two power supplies is not receiving power Action Check the switch power supply and the AC power source A2001 0001 power supply number installed ALARM CLEARED Meaning The specified Power Supply blade has been installed Action None A2001 0002 power supply number OK ALARM CLEARED Meaning The specified Power Supply blade is operating normally Action None 59060 07 D 2 45 2 Event Messages Alarm Events G A2001 0003 blade id Blade fault SENSOR FAULT CLEARED Meaning The internal fault on the specified Power Supply blade has been cleared Action None A2001 0004 blade id Blade fault AC FAULT ALARM CLEARED Meaning The specified Power Supply blade is
40. ID message_text Table 1 2 Event Log Message Format Component Description ordinal A number assigned to each message in sequence since that last time the alarm history was cleared time_stamp The time the alarm was issued in the format day month hh mm ss ms yyyy This time stamp comes from the switch for events that originate with the switch and from the workstation for events that originate from Enterprise Fabric Suite severity The event severity A Alarm C Critical W Warning I Informa tive source The program module or application that generated the event Sources include Zoning Switch PortApp EPort Management Server Alarms do not include the source message ID A number that identifies the message using the following format category message number message text The alarm message text Here is a sample of an informative level message from the Switch source 1 Wed May 26 12 30 29 965 UTC 2004 I 8400 0022 Switch Successful login user snmp IB session6 with admin privilege For more information about the CLI commands refer to the Command Line Interface Guide for your switch 59060 07 D Ed 1 Events and Event Logging Configuring the Event Log E Configuring the Event Log You can customize what events are recorded in the switch event log using the Set Log command With the Set Log command you can filter the events to be recorded by component specific ports an
41. LOST Meaning Communication with the blade was lost FW INIT FAIL Meaning Blade did not complete the initialization sequence FW POST FAIL Meaning Power On Self Test failure FW UPDATE FAIL 2 2 Meaning Firmware update to the secondary CPU blade failed 59060 07 D 2 Event Messages Fault Events ST ESS HW_BAD_SEATING Meaning HW MP ACCESS CPUO Meaning HW MP ACCESS CPU1 Meaning HW MP DATA MISMATCH Meaning HW POWERUP FAIL Meaning HW SENSOR FAULT Meaning Blade is improperly seated The maintenance panel SPROM data accessed through CPUO is either inaccessible or invalid The maintenance panel SPROM data accessed through CPU1 is either inaccessible or invalid The maintenance panel SPROMs accessed through CPUO and CPU1 are not identical Blade never established initial communications Hardware temperature voltage sensors are not functional HW UNSUPPORTED BLADE Meaning SENSOR FAULT Meaning temp sensor TEMP Meaning vollage sensor HIGH Meaning vollage sensor LOW Meaning 59060 07 D Installed blade is unknown or not supported Power Supply blade reports an internal fault The temperature sensor reading is out of range it is too high temp sensor can be BOARD 0 BOARD BOARD 1 DS1780 0 DS1780 DS1780_1 MAX1617 0 MAX1617 ASIC O0 ASIC MAX1617 1 ASIC 1 or MEZZ BOARD The voltage sensor voltage supply is out of range it is too high vollage sens
42. Logic direct customers may contact QLogic Technical Support others will be redirected to their authorized maintenance provider Visit the QLogic support Web site listed in Contact Information for the latest firmware and software updates For details about available service plans or for information about renewing and extending your service visit the Service Program web page at http Awww glogic com services QLogic offers training for technical professionals for all iSCSI InfiniBand and Fibre Channel products From the main QLogic web page at www glogic com click the Support tab at the top and then click Training and Certification on the left The QLogic Global Training portal offers online courses certification exams and scheduling of in person training Technical Certification courses include installation maintenance and troubleshooting QLogic products Upon demonstrating knowledge using live equipment QLogic awards a certificate identifying the student as a certified professional You can reach the training professionals at QLogic by e mail at training qlogic com Contact Information 59060 07 D QLogic Technical Support for products under warranty is available during local standard working hours excluding QLogic Observed Holidays For customers with extended service consult your plan for available hours For Support phone numbers see the Contact Support link at support glogic com Support Headquarters QLogic Corporatio
43. Port will be reset in an attempt to reestablish the ISL W 8B00 000D SMTP servers in the CallHome setup are using duplicate IP address and port number pairs Meaning The Call Home service configuration must not duplicate both the Simple Mail Transfer Protocol SMTP server IP address and port number values However the configuration may duplicate either the server IP address or the port number For better fault tolerance the SMTP servers should run on different physical systems The port number value of 25 is the well known service number for the SMTP protocol W 8B00 000E Message queue is empty cancelling attempts to retry sending last message Meaning The Call Home service was waiting to resend a message when the message expired or there was a request to clear the queue of all messages W 8B00 000F Will retry sending via SMTP server ip adaress port port number after seconds seconds Meaning After a communication failure or Simple Mail Transfer Protocol SMTP protocol error the switch attempts to resend the e mail message using the specified server port and delay 59060 07 D 2 69 2 Event Messages Warning Events EE W 8B00 0010 Will retry sending via SMTP server ip_address port port_number Meaning After receiving a transient error from the Simple Mail Transfer Protocol SMTP server on a e mail message sent to a recipient the Call Home service will attempt to resend the e mail message
44. The Ultimat ein Pe ormance Reference Guide Fibre Channel Event Message QLogic 3000 5000 9000 Series Fibre Channel Switch QLogic Intelligent Pass thru Module for IBM BladeCenter QLogic 20 Port SAN Switch Module for IBM BladeCenter QLogic Virtual Fabric Extension Module for IBM BladeCenter Firmware Version 7 x 8 x 9 x 59060 07 D Reference Guide Fibre Channel Event Message QLogic 3000 5000 9000 Series Fibre Channel Switch G a Information furnished in this manual is believed to be accurate and reliable However QLogic Corporation assumes no responsibility for its use nor for any infringements of patents or other rights of third parties which may result from its use QLogic Corporation reserves the right to change product specifications at any time without notice Applications described in this document for any of these products are for illustrative purposes only QLogic Corporation makes no representation nor warranty that such applications are suitable for the specified use without further testing or modification QLogic Corporation assumes no responsibility for any errors that may appear in this document Document Revision History Revision A August 2008 Firmware version 7 x 8 x 9 x Revision B October 2008 Revision C October 2009 Revision D November 2011 Changes Pages Affected Updated to support firmware version 8 0 2 32 2 34 2 69 2 75 2 76 Updated document format and branding Throughout
45. US server configuration using the Set Setup Radius command A1007 002E Ignoring RADIUS Server RAD US_server zero timeout configured Meaning Action A Remote Authentication Dial In Service RADIUS server was configured with invalid data for the timeout value A valid time out value is required to use the RADIUS server Set the timeout value in the switch RADIUS server configuration using the Set Setup Radius command A1007 002F Ignoring RADIUS Server RADIUS server no shared secret is configured Meaning Action A Remote Authentication Dial In Service RADIUS server was configured with invalid data for the shared secret A valid time out value is required to use the RADIUS server Set the shared secret in the switch RADIUS server configuration using the Set Setup Radius command A1007 0030 Security protocol not using chap unable to authenticate Meaning Action A Challenge Handshake Authentication Protocol CHAP negotiate frame was received that specifies an unsupported Diffie Helmann DH group type Check the remote device for a possible error condition Reset the port If errors continue disable CHAP for this device if it belongs in the fabric A1007 0031 Security protocol not using chap unable to authenticate Meaning Action 59060 07 D A Challenge Handshake Authentication Protocol CHAP negotiate frame was received that specified an unsupported hashing algorithm or an algo
46. ace route was canceled Action Retry the Fctrace command 59060 07 D 2 25 2 Event Messages Alarm Events N A1005 0055 Canceling TFTP operation as a result of a CPU switchover Meaning A CPU blade switchover occurred while a Trivial File Transfer Protocol TFTP operation was in progress The operation was canceled Action Retry the operation A1005 0057 Canceling the unpacking of a firmware image as a result of a CPU switchover Meaning A CPU blade switchover occurred while an firmware image unpack was in progress The unpack was canceled Action Retry the image unpack A1005 0058 Canceling the zoning edit mode as a result of a CPU switchover Meaning A CPU blade switchover occurred while a Zoning Edit session was in progress The Zoning Edit session was canceled Action Reopen the Zoning Edit session A1005 0059 Canceling the security edit mode as a result of a CPU switchover Meaning A CPU blade switchover occurred while a Security Edit session was in progress The Security Edit session was canceled Action Reopen the Security Edit session A1005 005A Canceling CIM edit mode as a result of a CPU switchover Meaning A CPU blade switchover occurred while a CIM Edit session was in progress The edit session was canceled Action Reopen the CIM Edit session A1005 005B Canceling system edit mode as a result of a CPU switchover Meaning A CPU blade switchover occurred while a system edit sess
47. aning The named blade fault has occurred Action Contact your authorized maintenance provider 59060 07 D 2 29 2 Event Messages Alarm Events E G A1005 0074 Blade seating is questionable Meaning A QLogic 9000 blade is improperly installed Action Examine the switch and reinstall blades as needed A1005 0075 Blade seating problem was resolved Meaning The QLogic 9000 blade seating problem as resolved Action None A1005 0076 Extraction latch is open Meaning A QLogic 9000 blade latch is open Action Examine the switch and close open latches A1005 0077 Extraction latch was closed Meaning The QLogic 9000 blade latch has been closed Action None A1005 0078 Extraction latch ignored until hotreset completes Meaning Extraction latch was opened while a switch hot reset was in progress Action Return the extraction latch to the closed position Wait until the hot reset is complete then remove the blade A1005 0079 Blade fault fault reported from primary CPU resetting switch Meaning A blade fault has occurred on the QLogic 9000 primary CPU blade and the switch is resetting Action Contact your authorized maintenance provider A1005 007A Blade fault fault reported from primary CPU powering off blades ports Meaning A blade fault has occurred on the QLogic 9000 primary CPU blade I O blades are being powered down Action Contact your authorized maintenance provider A1005 007C
48. ard zones Action Place both zone members in the same ACL hard zone or exclude both from ACL hard zones A1006 0005 Zoning enforcement error in Nameserver Meaning An error occurred while checking ACL zoning Action Contact your authorized maintenance provider A1006 0006 Zoning conflict device WWN and device WWN do not share an ACL hard zone but device WWN share a soft zone Meaning The named zone members cannot communicate because they are members of different ACL hard zones Action Place both zone members in the same ACL hard zone or exclude both from ACL hard zones A1007 0001 Security Unspecified zoning enforcement error Meaning A device was not authorized or it failed security checks and will not be allowed to join the fabric Action None 2 36 59060 07 D 2 Event Messages Alarm Events TO pEEEHEEENENENSIIZZZSZZZZZZ A1007 0002 Security Remote Switch with WorldWide Name WWN wwn configured for chap no chap configured for local switch 2 way Authentication Failure Meaning The device WWN is either not configured in the security database or it is not configured for Challenge Handshake Authentication Protocol CHAP Action Add the device WWN to the active security set if it missing or modify the group to allow for CHAP authentication with the other devices A1007 0005 Security Authentication request was rejected by port Meaning Indicates that a remote switch rejected a security au
49. atically set to False since LCFEnable has been set to True Meaning Setting the Set Config Port parameter LCFEnable to True automatically sets the Set Config Port parameter MFSEnable to False I 8400 003E Switch Readjusting TempMonitoringWarning from value C to value C Meaning The temperature threshold at which the switch issues a warning alarm is being changed I 8400 0040 Switch Readjusting TempMonitoringFailure from value C to value C Meaning The temperature threshold at which the switch issues a failure alarm is being changed I 8400 0048 Switch A CIM edit session has been canceled Meaning A Common Information Model CIM edit session has been cancelled I 8400 008C CallHome configuration has changed Meaning The Call Home service configuration was changed by the administrator I 8400 0090 IPsec configuration modified by user name at address session id Meaning The IPsec configuration was modified by the specified user who was logged in with the specified session identifier 59060 07 D 2 75 2 Event Messages Informative Events E A 1 8400 0091 IKE configuration modified by user_name at address session_id Meaning The IKE configuration was modified by the specified user who was logged in with the specified session identifier 1 8400 0094 IPSec configuration applied number errors detected Meaning The saved IPSec configuration data has been applied to the switch 1
50. authority mode was canceled by another user interface session that had the authority to do so C 8400 0008 Switch The switch will be reset in several seconds Meaning The switch is being reset as a result of a command from a user interface C 8400 0009 Switch The switch will hardreset in several seconds Meaning A hard reset of the switch is pending C 8400 000A Switch The switch will hotreset in several seconds Meaning A hot reset is pending C 8400 000B Switch The switch will be shutdown several seconds Meaning The switch will be shut down in several seconds C 8400 000C Switch Configuration is being restored this could take several minutes Meaning When a complete configuration restore is done on a switch a switch reset follows immediately to place the new configuration in effect 2 54 59060 07 D 2 Event Messages Critical Events TO I a C 8400 000E Switch Upgrading Licensed Ports to number of ports Meaning The number of licensed ports on the switch has been upgraded C 8400 000F Switch Attempted Licensed Port upgrade of ports that are already licensed Meaning The switch has already been upgraded to the number of licensed ports C 8400 0011 Switch The switch will be reset in several seconds due to a config restore Meaning Switch management is processing a config restore command C 8400 0012 Switch IOn Blade was inserted Meaning An I O blade
51. ce attempted to login as an Inter Switch Link ISL but that device was not configured in the port binding list Action Add the device to the port binding list 59060 07 D 2 19 2 Event Messages Alarm Events E A1004 0049 Eport Isolating due to Remote inactive Meaning The remote switch is unresponsive and the link has not been brought up The port will be isolated because the remote switch failed to respond Action Investigate the remote switch for connection problems A1004 0050 Maximum hard zoning member limit exceeded Reverting to soft zoning Requires port reset Meaning The maximum number of zone members associated with a port is limited to 64 If this number is exceeded the switch cannot enforce hard zoning and will revert to soft zoning Action Reduce the number of zone members associated with the port and reset the port A1004 0051 Blade IO blade number isolated due to startup problem Meaning There is an internal communication issue with an IO blade It will be set down until it clears Action If this problem persists contact your authorized maintenance provider A1004 0052 Eport Isolating due to Switch Binding failure Meaning A device attempted to login as an inter switch link but that device was not configured in the switch binding list Action Add the device to the switch binding list A1004 0053 Adding Denial of Service entry for source FC Address Oxadaress Meaning A n
52. d Meaning New firmware was successfully installed C 8400 0065 Switch The switch is being automatically hardreset after leaving the Diagnostics AdminState Meaning The switch automatically undergoes a hard reset after leaving the Diagnostics administrative state C 8400 0066 Switch IOn Blade is being automatically hardreset after leaving the Diagnostics AdminState Meaning I O blade is undergoing a hard reset after leaving the Diagnostics administrative state C 8400 0067 Switch The switch is entering Diagnostics AdminState and will automatically hardreset and have the configured AdminState when leaving the Diagnostics AdminState Meaning The switch is entering the Diagnostics state and will automatically undergo a hard reset The switch will return to the configured administrative state after leaving the Diagnostics administrative state C 8400 0068 Switch IOn Blade is entering Diagnostics AdminState and will automatically hardreset and have the configured AdminState when leaving the Diagnostics AdminState Meaning The I O blade is entering Diagnostics state and will automatically undergo a hard reset The I O blade will return to the configured administrative state after leaving the Diagnostics administrative state C 8400 0069 Switch Warning When leaving the Diagnostics AdminState of the primary CPU blade an automatic reset of the blade will occur The blade and the switch will c
53. d not be sent to the requestor 2 64 59060 07 D 2 Event Messages Critical Events TO EEE C 8B00 000A Unable to provide profile processing information the CallHome service is updating configuration Meaning Profile status information is not available while the Call Home service configuration is being updated C 8B00 000B Unable to change SMTP servers because the CallHome service is updating configuration Meaning You cannot change the active Simple Mail Transfer Protocol SMTP server while updating the Call Home service configuration C 8B00 000C FromEmailAddress has not been configured in the CallHome setup Messages cannot be sent to the SMTP server until this condition is corrected Meaning The FromEmailAddress must be specified in the Call Home service configuration This e mail address will receive notifications from the Simple Mail Transfer Protocol SMTP servers concerning e mail messages that could not be delivered C 8B00 001 2 Critical protocol failure with SMTP server Meaning Communications have failed or an unrecoverable Simple Mail Transfer Protocol SMTP protocol error has occurred on the active SMTP server C 8B00 0014 Successful recovery of SMTP communications Meaning Communications have been re established with one of the Simple Mail Transfer Protocol SMTP servers following a communications failure C 8B00 0016 SMTP server ip address port port number did not accept
54. d severity level You can choose from the following component events a E Port events Management server events Name server events Port events Switch management events Simple Network Management Protocol SNMP events m Zoning events For more information about the CLI commands refer to the Command Line Interface Guide for your switch Archiving and Downloading the Event Log You can use the CLI to create a file on the switch that contains the most recent 1200 entries This file can then be downloaded to the workstation using FTP To create and download a log file do the following 1 Log into the switch through Telnet and create an archive of the event log using the Set Log Archive command SANbox gt admin start SANbox admin gt set log archive This creates a file on the switch named ogfile 2 Open an FTP session on the switch and login with the account name images and password images Transfer the file ogfile in binary mode with the Get command gt ftp ip address user images password images ftp bin ftp gt get logfile XXXXX bytes sent in xx secs ftp gt quit 59060 07 D 1 Events and Event Logging Configuring Port Alarm Thresholds LSE Configuring Port Alarm Thresholds You can configure the switch to generate alarms for selected events Configuring an alarm involves choosing an event type rising and falling triggers a sample window and finally enabling or disabling the alarm
55. ddress FC adaress failed authentication verify MS security configuration Meaning Management server authentication is enabled and the received frame failed authentication Action Verify the MS group configuration A1005 000A Cannot enforce zoning for member domain D port number this zone member will be ignored Meaning A zone member given by domain ID and port number could not be found in the fabric Action Examine the fabric connections and zoning definitions A1005 000C Configuration error insufficient credit in pool Extended credit not granted for port port number Meaning Insufficient credits were available in the credit pool to grant the credit request Action Decrease the number of requested credits or add more donor ports A1005 000D Configuration error insufficient credit in pool Extended credit not granted for port port number Meaning Insufficient credits were available in the credit pool to grant the credit request Action Decrease the number of requested credits or add more donor ports 59060 07 D 2 21 2 Event Messages Alarm Events E a A1005 000E Configuration error can t extend credit on loop capable ports Extended credit not granted for port port_number Meaning Loop ports cannot borrow credits from the credit pool Action Change the port type to G_Port or F_Port A1005 0013 Hotswap procedure failed must hardreset switch Meaning The blade hot swap procedure fail
56. de Name WWN device WWN not allowed to join fabric Meaning The switch with the specified worldwide name is not allowed to join the fabric Action Add the switch to a group in the active security set A1004 0030 Topology change lost route to switch with domain ID domain D Meaning Connection to a switch in the fabric was lost Action Inspect switch connections and device hardware for proper operation Review accompanying alarms for other causes 59060 07 D 2 17 2 Event Messages Alarm Events EE A1004 0032 E_Port not supported on remote port Reconfigure remote switch to connect Meaning An E Port isolated because the port on the remote switch could not configure itself as an E Port Action Change the port type on the remote switch to G Port or GL Port A1004 0033 Remote switch is in Interop mode or using Legacy Address Format Meaning A remote switch is attempting to connect with conflicting settings for Interop mode or legacy address format Action Configure the switches so that Interop mode and Legacy Address Format settings are the same throughout the fabric A1004 0034 Failed to connect to a switch due to incompatibility contact technical support Meaning The two switches are incompatible Possible causes include incompatible interoperability mode configurations incompatible firmware versions and incompatible licensing Action Verify that the interoperability mode settings firmware
57. does not have an entry for itself within the active security set ISL group Action Edit the ISL group to include the local switch A1007 000F Security Chap session Gen Response indicates error chap unable to authenticate Meaning An Authentication Response frame cannot be built because the Challenge Handshake Authentication Protocol CHAP session is not in the right state The port will isolate Action Check the remote device for a possible error condition Reset the port to retry again If errors continue disable CHAP for this device if the device belongs in the fabric 2 38 59060 07 D 2 Event Messages Alarm Events A M A1007 0010 Security Chap session Receive Challenge indicates bad state chap unable to authenticate Meaning The Challenge Handshake Authentication Protocol CHAP session state is not in the correct state for a challenge message The port will isolate Action Check the remote device for a possible error condition Reset the port to retry again If errors continue disable CHAP for this device if the device belongs in the fabric A1007 0011 Chap failure isolating with Invalid Attach Meaning Frame does not match format for a Challenge Handshake Authentication Protocol CHAP status frame Ports will isolate Action Check the remote device for a possible error condition Reset the port to retry again If errors continue disable CHAP for this device if it belongs in the fabric A100
58. e exceeded size number of zones limitz maximum number of zones Meaning The maximum number of members allowed for the given zone has been exceeded because of a zone merge Action Reduce the number of members in the given zone on the remote switch A1003 0020 Failing remote zoning configuration total zone limit would be exceeded Meaning The maximum number of zones allowed on the switch has been exceeded because of a zone merge Action Reduce the number of zones on the remote switch 2 6 59060 07 D 2 Event Messages Alarm Events A MMMM A1003 0021 Failing remote zoning configuration Zoneset is empty Meaning An empty zone set was included as part of a zone merge and was rejected Action Modify the zoning database on the remote switch to remove or correct the empty zone set A1003 0022 Unable to update database with newly activated information Zoning Save in Progress Meaning Modifications were being made to the security or zoning database while a security set or zone set was being activated or deactivated from a remote switch Action Try the activation or deactivation again later A1003 0023 Fabric Busy Zoneset operation failed Meaning The activation or deactivation of a zone set failed because the fabric is currently busy Action Try the activation or deactivation again later A1003 0024 Request already in progress internal lock held Meaning A fabric operation is currently in
59. e by a remote switch Action Wait for the lock to time out and try again A1003 000C Fabric Busy failing lock request from domain domain D Meaning The command failed because the fabric is busy with another command in progress Action Wait 10 seconds and retry the command A1003 000D Fabric already locked by domain domain D Meaning The switch given by the domain ID has locked the fabric Action Unlock the domain ID lock on the switch given by domain ID A1003 000E Couldn t acquire lock from domain domain D Meaning The fabric may be changing and therefore could not acquire the lock Action Wait for the fabric to stabilize then try again 2 4 59060 07 D 2 Event Messages Alarm Events ls A1003 0010 Segmenting zoneset zone_set_name not defined Meaning Action In non interop mode there is a conflict in the zoning configuration causing the Inter Switch Link ISL to isolate The zone set is not found within the local zoning data base while interop mode is disabled Contact your authorized maintenance provider A1003 0011 Segmenting zoneset zone set name already active Meaning Action In non interop mode there is a conflict in the zoning configuration causing the Inter Switch Link ISL to isolate A switch tried to activate a zone set that is already active while interop mode is disabled Contact your authorized maintenance provider A1003 0012 Segmenting zoneset zone
60. ed for the switch symbolic name therefore the switch symbolic name was not changed to match the registered name 1 8200 0200 mserver Rejecting request GZM for zone zone name containing unsupported alias member s Meaning The fabric zone server command GZM Get Zone Member was rejected because the requested zone member was an alias that is not defined in Fibre Channel General Services 3 FC GS 3 1 8200 0201 mserver Rejecting request command command Meaning A fabric zone server command was rejected for the reason detailed in the message This can be caused by two users attempting to configure the switch or zoning database at the same time Contact your authorized maintenance provider if the reason for the failure is not clear 2 72 59060 07 D 2 Event Messages Informative Events A HMM I 8200 0202 mserver Rejecting request GZS for zone set zone set name containing unsupported alias member s Meaning The fabric zone server command GZS Get Zone Set was rejected because the requested zone set contains one or more members that are aliases Since aliases are not defined in GS 3 the request could not be completed I 8200 0300 mserver Cannot register HBA World Wide Name WWN device WWN FDMI database has reached its configured limit Meaning The switch contains a database that is configured to allow a certain number of HBAs to register Fabric Device Management Interface FDMI information wi
61. ed or the procedure was not followed correctly Action Perform a hard reset A1005 0020 Warning development logging is enabled Meaning Development logging is enabled Action Contact your authorized maintenance provider A1005 0024 Switch must be reset after leaving the Diagnostics Admin State Meaning After changing the switch administrative state from Diagnostics to any other state the switch must be reset to complete the state change Action Reset the switch A1005 0034 System resource error contact technical support Meaning There is a system resources problem on the switch Action Contact technical support A1005 0035 System resource error contact technical support Meaning There is an internal problem on the switch Action Contact technical support A1005 0036 Hotswap procedure failed before last reset must hardreset switch Meaning The blade hotswap procedure failed and the switch was reset without a power on self test Meaning Reset the switch with a hard reset A1005 0037 Hotswap procedure never completed the blade will not be functional until the switch is hardreset Meaning The blade hot swap procedure was not completed Action Reset the switch with a hard reset A1005 0038 Switch incompatibility error contact technical support Meaning Switch incompatibility error Action Contact technical support 2 22 59060 07 D 2 Event Messages Alarm Events ls A1005
62. eded size member number limitz member limit Meaning Action A fabric merge failed because the combined number of members in two zones having the same name exceeds the limit for the number of members in a zone Remove members either from the zone on the local switch or the remote switch so that the combined sum is less than member limit A1003 0037 Merge failed Total zone member limit would be exceeded Meaning Action 59060 07 D A fabric merge failed because the total number of zone members exceeds the zoning database limit Remove zone members either from the local switch or the remote switch so that the combined sum is less than member limit 2 Event Messages Alarm Events EENNNNNM A1003 0038 Merge failed Total zones in zonesets limit would be exceeded Meaning A fabric merge failed because the total number of zones in zone sets exceeds the zoning database limit Action Remove zones either from the local switch or the remote switch so that the combined sum is less than the zones in zone sets limit A1003 0039 Merge failed total zone limit would be exceeded Meaning A fabric merge failed because the total number of zones exceeds the zoning database limit Action Remove zones either from the local switch or the remote switch so that the combined sum is less than maximum zone limit A1003 003A Zone Merge conflict for ZoneSet zone_set_name Zone mismatch for zone zone_name check
63. emote Authentication Dial In Service RADIUS server configuration problem Action Check the shared secret The shared secret must be configured on both the RADIUS server and the switch 2 40 59060 07 D 2 Event Messages Alarm Events ls A1007 0023 Invalid response authenticator from RADIUS server P_address port check shared secret Meaning There is a Remote Authentication Dial In Service RADIUS configuration problem Action Confirm that the shared secret configured on the switch is identical to the shared secret configured on the RADIUS server A1007 0024 Invalid access accept from RADIUS server P adadress port bad or missing Service Type Meaning A service type Remote Authentication Dial In Service RADIUS attribute was not found in a RADIUS packet Action This is a RADIUS server configuration issue Consult your RADIUS server documentation A1007 0025 Security feature not supported Meaning The switch is coming out of Non Disruptive Code Load and Activation NDCLA and had an active security prior to the NDCLA but the security feature is no longer supported Action A license key may be required for the security feature A1007 0026 Unable to validate Chap Response from device_WWN possible Chap secret misconfiguration or security breach attempt Meaning A Challenge Handshake Authentication Protocol CHAP authentication attempt failed due to failure while comparing secrets Action Chec
64. enode mac within the enode mac list or configure RequireEnodeMacConfig to false so that Enode mac s are not required to be configured A1005 0120 PI ADJACENT SERDES NOTIFICATION error Policy policy name reason Meaning Action 59060 07 D Port not configured as PT being downed due to sharing hardware SerDes with PT port Configure port as PT port type if desired to run 2 35 2 Event Messages Alarm Events E A1005 0121 PT_PARTNER_OFFLINE_NOTIFICATION error Policy policy_name reason Meaning PT port being downed because partner cannot go online Action Confirm that the PT partners are configured for the same speed Confirm that the correct Ethernet media is installed Confirm that the attached device is operating properly A1005 0122 APP HEARTBEAT LOST error Policy policy name reason Meaning Communication lost to application Action Contact technical support A1005 0123 FCF SINGLE VLAN SUPPORTED error Policy policy name reason Meaning Single VLAN support per FCF The VLAN is being implemented for the FCF index Action This version of firmware only supports a single VLAN per FCF More than one VLAN was found to be configured for this specified FCF but only the first one in the list will be used A1006 0004 Zoning conflict device WWN is in an ACL hard zone but device WWN share a soft zone Meaning The named zone members cannot communicate because they are members of different ACL h
65. er Fault Events The following fault messages apply only to QLogic 9000 series Fibre Channel switches Fault events like alarms require administrator attention and may require assistance from your authorized maintenance provider AC FAULT Meaning AC power may be unplugged or switched off AUX PORT ERROR Meaning At least one internal FC link is not functional FAN FAULT DETECTED Meaning Fan blade reports an internal fault FAN FLOW MISMATCH Meaning Incompatible air flow directions FANO FAN1 PSO PS1 FANO MISSING Meaning FANO is not installed 59060 07 D 24 2 Event Messages Fault Events EENNNNNM FAN1 MISSING Meaning FAN1 is not installed FW APP FAIL Meaning Internal application failure FW APP PEER FAULT Meaning Application declared an error communicating with other CPU FW APP SELF FAULT Meaning Application declared an internal fault FW APP STARTUP FAIL Meaning Application is unable to complete startup processing FW FILE SYSTEM REMADE Meaning A Remake Filesystem command was performed in maintenance mode FW FT APP REG FAIL Meaning Application is unable to register with Fault Tolerant FT manager FW FT APP SYNC FAIL Meaning Failure to synchronize data to the secondary CPU blade FW FT CPU FAILOVER FAILED Meaning Unable to complete failover process FW FT NO ABDICATE REPLY Meaning Unable to failover due to lack of secondary CPU blade response FW HEARTBEAT
66. esides in the zoning database The active zone set will not be added to the full zone set sequence to prevent inconsistency in the zoning database Action Deactivate the active zone set to keep the fabric consistent A1003 0059 Failing remote zoning configuration zone member type not supported Meaning A remote switch s zoning configuration contains a zone member type that is not supported Action Edit the zone to remove the unsupported member type A1003 0060 Zone Merge conflict Alias mismatch for alias alias check members Meaning The zone merge failed due to an alias mismatch Action Examine the zoning configuration for conflicts A1003 0062 Failing delete orphans zoning request fabric locked by switch with domain ID domain ID Retry command later Meaning An attempt was made to delete the orphan zones while the fabric was locked Action Retry the command later A1003 0063 Failing delete orphans zoning request fabric busy Retry command later Meaning An attempt was made to delete the orphan zones while the fabric was busy Action Retry the command later A1003 0064 UFC failure received from domain domain D Meaning An Update Fabric Configuration UFC message was received with a failed status from the switch given by domain ID Action Check the status of the switch at the given domain ID A1003 0066 ISL group entry for switch wwn does not contain valid binding configuration Entry should
67. essages for QLogic Fibre Channel switches This manual is organized as follows This preface describes the intended audience related materials and technical support Section 1 describes event logging concepts including definitions of severity levels how to configure the event log how to display the event log and how to download the event log from the switch Section 2 describes the message format and lists the messages Intended Audience This manual is for Storage Area Network SAN administrators to provide a reference for switch alarm messages their meanings and follow up actions Related Materials The Fibre Channel Standards are available from Global Engineering Documents 15 Inverness Way East Englewood CO 80112 5776 Phone 800 854 7179 or 303 397 7956 Fax 303 397 2740 Documentation Conventions This guide uses the following documentation conventions 59060 07 D NOTE provides additional information CAUTION indicates the presence of a hazard that has the potential of causing damage to data or equipment WARNING indicates the presence of a hazard that has the potential of causing personal injury Preface Documentation Conventions E B Textin blue font indicates a hyperlink jump to a figure table or section in this guide and links to Web sites are shown in underlined blue For example L Table 9 2 lists problems related to the user interface and remote agent Q See Installat
68. f there are 32 active transparent routes on the F FL Port reduce the number of mappings on that port A1005 0107 TR Proxy Login failed wwn already logged into local fabric at FC ID fc d Meaning A proxy for a device in a remote fabric could not be created in the name server of the local fabric because a device with the same port name was already logged in Action Examine the adapters with the given WWN and determine which is using the incorrect world wide name A1005 0108 TR Port internal error encountered Meaning An internal inconsistency was detected by the switch firmware that affected a transparent route Action Contact your authorized maintenance provider A1005 0109 TR ignored f zone and f zone port wwn shared but two TR ports port wwn port wwn used Meaning The zone set contains inter fabric zones IFZ that shared the same device port name but uses different TR Ports on the same switch Action Remove one of the inter fabric zones or modify them so that both zones use the same TR Port A1005 010A Remote fabric attached to port does not support NPIV Meaning A TR Port could not log into a remote fabric because the remote fabric port does not support N Port ID Virtualization NPIV Action Enable NPIV on the switch attached to the TR Port or use a different remote fabric switch port A1005 010B IPSec configuration error IKE Peer peer name error description Meaning An error occurred
69. failed processing Either the payload of the frame did not match the standard layout of the frame or the Challenge Handshake Authentication Protocol CHAP session between the devices being authenticated was not in the state where the negotiate frame was expected Action Check the remote device for a possible error condition Reset the port to retry again If errors continue disable Challenge Handshake Authentication Protocol CHAP for this device if it belongs in the fabric A1007 002C Security Authentication protocol msg AUTH DONE inconsistent with Authentication protocol in progress Meaning The local switch received an AUTH DONE command authentication frame while the Challenge Handshake Authentication Protocol CHAP session was not in the correct state to expect this type of frame The remote device is not following standard authentication protocol Action Check the remote device for a possible error condition Reset the port to retry again If errors continue disable CHAP for this device if the device belongs in the fabric 2 42 59060 07 D 2 Event Messages Alarm Events TO ESE A1007 002D Ignoring RADIUS Server RADIUS server invalid UDP port configured Meaning Action A Remote Authentication Dial In Service RADIUS server was configured with invalid data for the User Datagram Protocol UDP port This configuration field is required to use the RADIUS server Set the UDP port value in the switch RADI
70. g list A1007 0036 Port taken offline due to port binding failure following configuration change Meaning A configuration change was made to the port binding list such that the device s on the port were no longer allowed to be logged in Action Add the devices to the port binding list A1007 0037 Device device wwn failed port binding Meaning A switch device attempted to login as an Inter Switch Link ISL but that device was not configured in the port binding list for the specified port Action Add the device to the port binding list A1007 0038 Device device wwn failed switch binding Meaning A switch device attempted to login as Inter Switch Link ISL but that device was not configured in the switch binding list Action Add the device to the switch binding list 2 44 59060 07 D 2 Event Messages Alarm Events TO SES A1007 0039 Ignoring RADIUS Server server no shared secret configured Meaning An attempt was made to authenticate a switch login through a Remote Authentication Dial In Service RADIUS server but no shared secret exists Action Configure a shared secret A1007 003A Using local user authentication No radius servers configured for user authentication Meaning A Remote Authentication Dial In Service RADIUS configuration was set to authenticate user accounts through a RADIUS server but no RADIUS server was configured User accounts will be authenticated by the switch Action
71. have been connected and their zoning databases have been merged C 8400 0083 blade id Blade fault FW APP FAIL processing pending graceful re route Meaning There has been an internal application failure on the specified blade C 8400 008D Illegal configuration detected based on licensing Configuration will be updated Meaning The restoration of a configuration backup has violated current feature licensing The active configuration will be automatically updated based on current licensing C 8400 008E Inconsistent configuration defaults detected Defaults will be updated Meaning Two fabrics have been connected and their zoning databases have been merged C 8400 008F Attempted speed licensed upgrade that is already enabled Meaning An attempt was made to install a license for a port speed that is already operable on the switch C 8400 0095 The switch VWWN is being upgraded Meaning The license upgrade was successful C 8400 0096 Secondary CPU firmware update complete Meaning The update of the firmware image on the secondary CPU is complete 59060 07 D 2 61 2 Event Messages Critical Events EENNNENENENENENNNENNENNNM V w V V OoO m PPbPt d C 8500 00A2 Switch MSG ID SWITCH LLDPD RESTARTED Meaning The LLDPD daemon has been restarted C 8600 0009 PortApp Port port number Link reset LR to be performed on port port number Meaning The port will perform a lin
72. have binding domain domain D Meaning A switch in the fabric is using a domain ID that differs from the configured fabric binding domain ID Action Change either the current switch domain ID or the fabric binding domain ID so that they match 59060 07 D 2 13 2 Event Messages Alarm Events E E A1003 0069 Failing remote zoning configuration invalid zone data received Meaning Zoning activation failed because the switch detected invalid zoning data that is not supported in the local interop mode Action Check your zoning configuration and remove incompatible zone members A1004 0001 Port in active hard zone but not installed or present on this switch Meaning A zone member in an ACL zone on this switch is defined with an invalid port number Action Examine the fabric and correct the zone membership A1004 0005 No communication from neighbor switch on port port_number with domain ID domain_ID lost route Meaning This switch has not received a hello from the remote switch for 80 seconds The routes learned through this link are discarded Action None A1004 0008 Eport Isolating due to ELP Incompatibility Meaning An E Port isolated due to an ELP Exchange Link Parameter incompatibility Action Review the accompanying alarms for a specific cause A1004 0009 Eport Isolating due to ESC Incompatibility Meaning An E Port isolated because the connecting switch failed to support the standard ro
73. he Call Home service will attempt to resend the message W 8B00 0018 CallHome message send for profile profile to recipient email_address failed on SMTP server jp address port port number Retry failed ignoring recipient Meaning The Call Home service attempt to resend an e mail message to the recipient in the named profile through the specified Simple Mail Transfer Protocol SMTP server has failed The Call Home service will not attempt to resend the message 2 70 59060 07 D 2 Event Messages Warning Events ls W 8B00 0019 CallHome message send for profile profile to recipient email_address failed on SMTP server ip adaress port port number Retry will not be attempted ignoring recipient Meaning The Call Home service failed to send an e mail message to the recipient in the named profile through the specified Simple Mail Transfer Protocol SMTP server because of a non transient error The Call Home service will not attempt to resend the message W 8F00 000C Fabric Status status Meaning The severity of the fabric status has changed The description field will show the reason for fabric status W 8F00 000D Switch Status status Meaning The severity of the switch status has changed The description field will show the reason for the switch status W 8F00 000E Link Status status Meaning The severity of the link status has changed The description field will show the reason for link status 59060
74. he condition is no longer present A1005 0116 DCBX NEIGHBOR LOST error Policy policy name reason Meaning Action LLDP found no neighbors on link DCBX is disabled No LLDP neighbor has been detected on the link or an existing neighbor has been aged out and removed DCBX cannot enable the link until neighbor information is refreshed A1005 0117 DCBX PEER UNADVERTISED error Policy policy name reason Meaning Action LLDP neighbor on link is not sending DCBX TLVs An LLDP neighbor is present on the link but the LLDP PDU does not contain any DCBX TLVs DCBX cannot enable the link until neighbor information is refreshed A1005 0118 DCBX PEER UNADVERTISED error Policy policy name reason Meaning Action Peer on link has not enabled the DCBX Priority Group Priority Flow Control feature An LLDP neighbor is present on the link and the LLDP PDU contains DCBX TLVs but the specified feature is not advertised by the peer DCBX cannot enable the link until the feature is present A1005 0019 DCBX PEER FEATURE DISABLED error Policy policy name reason Meaning Action 2 34 Peer on link has not enabled the Priority Group Priority Flow Control feature An LLDP neighbor is present on the link and the LLDP PDU contains DCBX TLVs for the specified feature but the feature is not enabled by the peer DCBX cannot enable the link until the feature is present 59060 07 D 2 Event Messages
75. he specified port for problems or adjust the rising trigger or sample window A4004 0001 Decode errors of 4024 hit rising trigger 500 in 1 second window on this port ALARM SET Meaning Decode errors have exceeded the threshold set during the specified sample window interval If the number of decode errors decreases below the lower threshold during the next sample window interval then the alarm condition will clear Action Investigate the specified port for problems or adjust the rising trigger or sample window A4004 0002 Decode errors alarm on this port has been in ALARM SET state for 3 seconds PORT DOWNED Meaning A port has failed the decode error threshold limit for 3 consecutive sample window intervals and has been disabled Action Reset the port reactivate the switch configuration set the port state to online or reset the switch A4084 0002 Decode errors error threshold monitoring is being reset on this port ALARM CLEARED Meaning The number of decode errors has decreased below the lower threshold thus clearing the decode error threshold alarm Action None A6000 0002 Configured port speed for port port number not compatible with media Meaning The transceiver in the named port is not capable of transmitting at the configured port speed Action Reconfigure the port speed or replace the transceiver A6000 0005 Configured port type for port port number not compatible with media Meaning
76. ingEnabled parameter is different on the two switches 59060 07 D 2 37 2 Event Messages Alarm Events N A1007 000A Security Dropping lock held by domain domain_id for number seconds Meaning A remote switch has held the fabric lock for too long The local switch is dropping the lock in order to send out a Exchange Fabric Membership Data EFMD frame Action None A1007 000B Security EFMD Rejected bad revision Meaning The remote switch is running at a different Exchange Fabric Membership Data EFMD version level than the local switch Ports will isolate Action None A1007 000C Security policy restrict mode security db differs Meaning The current security policy calls for Restrict Mode which means that all switches in the fabric must have the same security databases or the inter switch links will not log in In this case the security databases differ Action Reconfigure the active security set so that the ISL group members are the same A1007 000D Security policy in mode mode other switch in mode mode sec db conflict Meaning The security policy on the local switch differs from that of the remote switch Action Configure the security policy on the remote switch to match that of the local switch A1007 000E Security Auth challenge received from WWN port WWN not Authorized to join Meaning A challenge authentication frame was received from a remote switch but the local switch
77. ion Checklist on page 3 6 Q For more information visit www glogic com a Text in bold font indicates user interface elements such as a menu items buttons check boxes or column headings For example C Click the Start button point to Programs point to Accessories and then click Command Prompt CQ Under Notification Options select the Warning Alarms check box W Text in Courier font indicates a file name directory path or command line text For example C Toreturn to the root directory from anywhere in the file structure Type cd root and press ENTER Q Enter the following command sh install bin m Key names and key strokes are indicated with UPPERCASE Q Press CTRL P J Press the UP ARROW key B Textin italics indicates terms emphasis variables or document titles For example CQ Fora complete listing of license agreements refer to the QLogic Software End User License Agreement C What are shortcut keys To enter the date type mm dd yyyy where mm is the month dd is the day and yyyy is the year W Topic titles between quotation marks identify related topics either within this manual or in the online help which is also referred to as the help system throughout this document vi 59060 07 D Preface Technical Support ST gt Technical Support Training Customers should contact their authorized maintenance provider for technical support of their QLogic products Q
78. ion has been canceled Meaning The zoning configuration edit session has been canceled as a result of the Zoning Cancel command I 8400 002B Switch User login account name is being closed In Band connections have been disabled Meaning The session has been closed as a result of a configuration change 1 8400 002C Switch User login session session D user account name has timed out Meaning A user login session has ended because of inactivity 1 8400 0036 Switch Hotreset not permitted at this time try again later Meaning Conditions exist that will not allow a hotreset Try again later 2 74 59060 07 D 2 Event Messages Informative Events A I 8400 0037 Switch VIEnable automatically set to False since MFSEnable has been set to True Meaning Setting the Set Config Port parameter MFSEnable to True automatically sets the Set Config Port parameters VIEnable and LCFEnable to False I 8400 0038 Switch LCFEnable automatically set to False since MFSEnable has been set to True Meaning Setting the Set Config Port parameter MFSEnable to True automatically sets the Set Config Port parameters VIEnable and LCFEnable to False 1 8400 0039 Switch MFSEnable automatically set to False since ViEnable has been set to True Meaning Setting the Set Config Port parameter VIEnable to True automatically sets the Set Config Port parameter MFSEnable to False I 8400 003A Switch MFSEnable autom
79. ion states low alarm low warning normal high warning high alarm Action For the temperature sensor transitioning from low alarm to high alarm cool the system For all other sensors transitioning from low alarm to high alarm replace the media A1005 0050 Media device device nameis value units Transitioning from state to state Meaning The specified sensor temperature voltage TxBias TxPower RxPower has cleared an existing fault The sensor reports its value Celsius volts milliAmps milliWatts and transition states low alarm low warning normal high warning high alarm Action None A1005 0051 Canceling config edit mode as a result of a CPU switchover Meaning A CPU blade switchover occurred while a Config Edit session was open The Config Edit session was canceled Action Reopen the Config Edit session A1005 0052 Canceling IP ping as a result of a CPU switchover Meaning A CPU blade switchover occurred while an Ethernet ping was in progress The Ethernet ping was canceled Action Retry the Ping command A1005 0053 Canceling FC ping as a result of a CPU switchover Meaning A CPU blade switchover occurred while an Fibre Channel ping was in progress The Fibre Channel ping was canceled Action Retry the Fcping command A1005 0054 Canceling FC Trace Route as a result of a CPU switchover Meaning A CPU blade switchover occurred while an Fibre Channel trace route was in progress The tr
80. ion was in progress The edit session was canceled Action Reopen the system edit session A1005 005C Canceling SNMP edit mode as a result of a CPU switchover Meaning A CPU blade switchover occurred while an SNMP edit session was in progress The edit session was canceled Action Reopen the SNMP edit session A1005 005D Canceling Radius edit mode as a result of a CPU switchover Meaning A CPU blade switchover occurred while a Remote Authentication Dial In Service RADIUS edit session was in progress The edit session was canceled Action Reopen the RADIUS Edit session 2 26 59060 07 D 2 Event Messages Alarm Events ls A1005 005E Canceling Services edit mode as a result of a CPU switchover Meaning A CPU blade switchover occurred while a services edit session was in progress The edit session was canceled Action Reopen the services edit session A1005 005F Canceling Nicknames edit mode as a result of a CPU switchover Meaning A CPU blade switchover occurred while a nicknames edit session was in progress The edit session was canceled Action Reopen the nicknames edit session A1005 0060 A control link between b ade D and blade ID via blade ID has failed blade control is not fully redundant contact technical support Meaning A portion of the control plane network on the switch has failed The switch should continue to function normally but any further failures may cause the switch to ma
81. isruption during hot reset Meaning Some ports were disrupted during the hot reset operation C 8600 0017 PortApp External port license count exceeded downing external port port number Meaning The named external port is down because the number of licensed external ports has been exceeded 2 62 59060 07 D 2 Event Messages Critical Events TO ESSA C 8600 0018 PortApp External port license became available re starting downed external ports Meaning An external port that was previously down because of insufficient port licenses is now online C 8600 0019 PortApp Internal port license count exceeded downing internal port port number Meaning A device attempted to login to an internal port but a license was not available A license upgrade may be required or a license may be released by downing ports C 8600 001A PortApp Internal port license became available re starting downed internal ports Meaning A license has become available and ports that had been previously downed to due to unavailable licenses will be restarted C 8600 001B RX Seq Error D ID sequence destination S ID sequence source SEQ ID sequence ID OX D originator exchange RX ID recipient exchange CMPLT complete status NFRAMES frame count Meaning An error was encountered while handling the receive sequence referenced in the log message Contact your authorized maintenance provider C 8700 0007 EPort Port port
82. k reset LR due to a loss of credit problem C 8600 000A PortApp Port port number Link reset LR to be performed on port port number Meaning The port will perform a link reset LR due to a loss of credit problem C 8600 000B PortApp Port port number Link reset LR to be performed on port port number Meaning The port will perform a link reset LR due to loss of credit issue C 8600 0013 PortApp Invalid vendor data from media device for port port number Meaning The switch could not read and verify the media module ID This may indicate a discovery error or a bad checksum in the serial ID Other possibilities include an improperly installed media module or an internal media I O hardware fault C 8600 0014 PortApp Invalid vendor data from media device for port port number Meaning The switch could not read and verify the media module ID This could be caused by a media discovery error a bad checksum in the media serial ID an improperly installed media or an internal media I O hardware fault C 8600 0015 PortApp Unresponsive device a pa on port port number removed from the fabric Meaning A device on the loop port did not take an OPN primitive off the loop destined for it This suggests the device either has been physically removed or is faulty In addition it has been removed from the fabric nameserver C 8600 0016 PortApp Online port s port numbers were reset due to d
83. k security configuration A1007 0027 Radius server could not validate authentication response from port number Meaning Remote Authentication Dial In Service RADIUS authentication failed Action Confirm that the secret is the same on the switch as it is on the RADIUS server A1007 0028 Security 2 Way Authentication No security entry found for port Meaning Unable to locate a security member entry to complete a two way authentication Action Edit the group to include the port 59060 07 D 2 41 2 Event Messages Alarm Events gt G A1007 0029 Security protocol not using chap unable to authenticate Meaning A Challenge Handshake Authentication Protocol CHAP negotiate frame that specifies an unsupported authentication protocol was received Action Check the remote device for a possible error condition Reset the port to try again If errors continue disable CHAP for this device if the device belongs in the fabric A1007 002A Inconsistent Fabric Binding configuration Enabled on remote switch s disabled on local switch Meaning Inconsistent fabric binding configuration settings between local and remote switch All switches in the fabric must have the same configured fabric binding setting Action Enable or disable fabric binding on all switches A1007 002B Security Chap session Negotiate Authentication failed Meaning The local switch received an authentication negotiate frame which
84. lfunction Action Contact your authorized maintenance provider A1005 0061 A control link between blade D and blade ID via blade ID is now functioning normally Meaning The control link has recovered and is functioning normally Action None A1005 0063 CPU never entered HotStandby state Meaning Secondary CPU never entered Hot Standby state and therefore the switch is not fault tolerant Action Contact your authorized maintenance provider A1005 0064 Switch is not fault tolerant Fault Tolerant license is installed but only 1 CPU blade installed Meaning The Fault Tolerant license key was installed on a QLogic 9000 switch with only one CPU blade Action Install the second CPU blade A1005 0065 Fault Tolerant license is installed but secondary CPU s latch is open so unable to become Fault Tolerant Meaning The QLogic 9000 switch is not fault tolerant because the secondary CPU blade is not fully installed Action Close the secondary CPU blade latch 59060 07 D 2 27 2 Event Messages Alarm Events E G A1005 0066 Switch is not fault tolerant Fault Tolerant license is installed but secondary CPU is faulted Meaning The QLogic 9000 switch is not fault tolerant because of a fault on the secondary CPU blade Action Replace the secondary CPU blade A1005 0067 HyperStack tm license installed but only 1 CPU blade installed alarm status Meaning A QLogic 9000 switch that is licensed for
85. mber_type unsupported Meaning An invalid zone member type was discovered in a zone ACL hard zone membership must be defined by domain ID and port number Action Correct the member type A1003 0041 Zoning objects which contain Fibre Channel FC Address Members not being sent to remote switch on save not supported in this mode Meaning An attempt was made to assign a zone member by FC address while interoperability mode was disabled When Interop mode is disabled zone membership must be defined by worldwide name or domain ID and port number Action Enable Interop mode or change the zone membership type A1003 0048 Active Zone Set zoneset name no longer in database please deactivate zone set if not already in progress the save will be deferred until zone set no longer active Meaning The switch will not allow you to delete a zone set that has the same name as the active zone set from the zoning database Action Deactivate the active zone set before deleting the zone set has the same name A1003 004C Active ZoneSet containing Fibre Channel Address may cause fabric to segment due to switches that do not support this zone member type Meaning Some switches in the fabric may not support Fibre Channel address zone members in the active zone set Action Edit the necessary zone sets to use worldwide name zone membership A1003 004D Port group does not contain entry for this switch Meaning The security set can
86. n 4601 Dean Lakes Blvd Shakopee MN 55379 USA QLogic Web Site www qlogic com Technical Support Web Site http support glogic com Technical Support E mail support qlogic com Technical Training E mail training qglogic com vii Preface Technical Support E 3 Knowledge Base The QLogic knowledge base is an extensive collection of QLogic product information that you can search for specific solutions We are constantly adding to the collection of information in our knowledge base to provide answers to your most urgent questions Access the knowledge base from the QLogic Support Center http support glogic com viii 59060 07 D Events and Event Logging Messages originate from the switch from Enterprise Fabric Suite or from the QuickTools web applet in response to events that occur in the fabric This chapter describes the following topics W Understanding Severity Levels Displaying Events using the Event Browser Displaying the Events Using the Command Line Interface Configuring the Event Log Archiving and Downloading the Event Log Configuring Port Alarm Thresholds Understanding Severity Levels Events are classified by the following severity levels Table 1 1 Event Severity Levels Severity Level Description Fault Describes events that may require assistance from your autho rized maintenance provider Each fault event has a corresponding alarm message Alarm Describes events that are disrupti
87. nditions have been cleared W 8400 003D Switch Invalid user user_name attempted to log into switch Meaning Invalid user login attempt W 8400 007D Switch ntp attempting to synchronize to server at jp address Meaning The switch is attempting to synchronize its time with the Network Time Protocol NTP server at the specified IP address 2 68 59060 07 D 2 Event Messages Warning Events ls W 8400 0092 IPSec association association_name has expired Meaning The configured lifetime for the specified IPSec association has expired and the association has been deleted from the switch s active database W 8400 0093 IPSec policy policy_name has expired Meaning The configured lifetime for the specified IPSec policy has expired and the policy has been deleted from the switch s active database W 8400 0094 Ignoring IKE policy policy_name with non local address P_address Meaning The specified IKE policy has a local address that is not an IP address on the switch The IKE policy is ignored W 8700 0009 EPort Port port number Inter Switch Link ISL communication error Meaning The remote switch has lost the local switch s identity W 8700 000A EPort Port port number No response from remote switch resetting Inter Switch Link ISL Meaning No communication has been received from the remote switch for some time indicating that it may not be functioning properly The E
88. not be activated because the port group does not have an entry for the local switch worldwide name Action Edit the port group to include the local switch worldwide name A1003 004E Group entry for local switch does not support authentication Meaning The local switch worldwide name group entry is not configured for authentication but other members within the group are This configuration is not allowed Action Change the local switch worldwide name entry to run Challenge Handshake Authentication Protocol CHAP authentication or remove CHAP authentication from other members of the group 59060 07 D 2 41 2 Event Messages Alarm Events E A1003 004F No Zone Merge Response Meaning A merge request was sent out to all switches in the fabric but a response was not received from at least one switch Action Check other switches in fabric to determine why a response was not sent A1003 0050 ISL group does not contain entry for this switch Meaning The Inter Switch Link ISL group does not contain an entry for the local switch worldwide name This is a required entry Action Add the switch worldwide name to the ISL group then activate the security set A1003 0051 Domain ID for local switch does not match fabric binding Meaning The configured fabric binding value for the local switch worldwide name does not match the current domain ID for the switch Action Change the fabric binding value for local switch
89. nt Action Change the domain ID of the device A1004 0039 WorldWide Name WWN device WWN currently in fabric no fabric binding in active security set for this WWN Meaning Fabric binding failed due to security incompatibility Action Check the security settings of the named device A1004 003F Request for Domain ID rejected WorldWide Name WWN device WWN not allowed to join fabric Meaning The switch with the specified WWN is not allowed to join the fabric Action Add the switch to a group in the active security set A1004 0040 World Wide Name WWN device WWN assigned domain domain ID fabric binding indicates it should use domain ID Meaning A fabric binding configuration was activated that conflicts with the current domain ID assignment Action Change the domain ID of the named device and then reconfigure the fabric A1004 0041 Eport isolating due to E Port License Exceeded Meaning An E Port isolated because all licensed E Ports are in use Action Obtain a license key to license additional E Ports A1004 0043 Forcing Domain ID change due to Interoperability setting from old domain IDto new domain ID Meaning The Domain ID of the switch is changed due to an interoperability configuration change The old Domain ID does not conform to the range of allowed Domain IDs for the new interoperability setting Action None A1004 0048 Eport Isolating due to Port Binding failure Meaning A switch devi
90. nt_name login rejected maximum logins already in use Meaning The attempted login was rejected because there are too many sessions There may be switch management sessions open on the switch that are no longer in use W 8400 001F Switch User account_name login rejected maximum logins already in use Meaning The attempted login was rejected because there are too many sessions There may be switch management sessions open on the switch that are no longer in use W 8400 0020 Switch User account_name login rejected maximum logins already in use Meaning The attempted login was rejected because there are too many sessions There may be switch management sessions open on the switch that are no longer in use W 8400 0021 Switch User account_name login rejected maximum logins already in use Meaning The attempted login was rejected because there are too many sessions There may be switch management sessions open on the switch that are no longer in use W 8400 0034 Switch Port port_number was Downed before hotreset due to excessive errors still DOWNED Meaning A port was disabled by the threshold monitoring application before the hot reset and is still disabled after the hot reset W 8400 0035 Switch Retrying port port_number that was Downed due to excessive errors Meaning A port that was disabled by the threshold monitoring application is periodically being retried to see if the error co
91. number Received frame from address not in Access Control List ACL hard zone src address FC address dest address FC adaress Meaning The destination for the receive frame is in an ACL zone and the source is not The frame will not be forwarded C 8700 000D EPort Port port number Resetting Inter Switch Link ISL a time out value has been reconfigured Meaning The Resource Allocation R A TOV or Error Detect E D TOV timeout value has been reconfigured E Ports will be automatically reset to inform the neighbor switch of the change C 8700 000E EPort Port port number InteropCredit value was reconfigured resetting port Meaning The InteropCredit parameter has changed The affected port will be automatically reset C 8700 000F EPort Port port number Broadcast frame received amp broadcast disabled discarding broadcast frames Meaning Broadcast is disabled and the switch has received a broadcast frame Enable broadcast to receive broadcast frames 59060 07 D 2 63 2 Event Messages Critical Events E C 8700 0010 EPort Port port number Inter Switch Link ISL unstable ISL init will be held back until ISL up time is 5 seconds Meaning The ISL is unstable indicating that the media module or the cable is bad C 8700 0011 Eport Port port number Connection failure remote switch not compatible Meaning The remote switch is not compatible with the local switch
92. of the ports did not pass the Power On Self Test POST Action Enter the Show Post Log command to investigate A3005 0001 000C value voltage sensor shows valueV ALARM SET Meaning A switch voltage sensor on a QLogic 5000 series switch is experiencing an out of range voltage condition Action Contact your authorized maintenance provider A3005 0001 000C Blade fault va ue V HIGH The value V voltage supply is out of range it is too high Meaning A high voltage blade fault has occurred on a QLogic 9000 switch Action Contact your authorized maintenance provider 2 48 59060 07 D 2 Event Messages Alarm Events TO ESE A3005 0001 000D Blade fault value HIGH PS 1 2V 2 The value V voltage supply is out of range it is too high Meaning A high voltage blade fault has occurred on an for IBM BladeCenter Module Action Contact your authorized maintenance provider A3005 0001 000E Blade fault va ue HIGH PS 1V The value V voltage supply is out of range it is too high Meaning A high voltage blade fault has occurred on IBM BladeCenter Module Action Contact your authorized maintenance provider A3006 0001 000C value voltage sensor shows valueV ALARM SET Meaning An out of range voltage condition has occurred on a QLogic 5000 switch Action Contact your authorized maintenance provider A3006 0001 000C Blade fault va ueV LOW The va ueV voltage supply is out of range it is too lo
93. ome back up in the configured AdminState Meaning The primary CPU blade is entering Diagnostics state and will automatically undergo a hard reset The I O blade will return to the configured administrative state after leaving the Diagnostics administrative state 59060 07 D 2 59 2 Event Messages Critical Events N PV Ti 1 A B A C 8400 006A Switch Upgrading License for Fabric Security Meaning The Fabric Security Bundle license was applied successfully C 8400 006B Switch Upgrading License for CLI Extended Credits capability Meaning The CLI Extended Credits license was applied successfully C 8400 0070 blade ID blade is operational Meaning The specified blade is powered on and fully operational C 8400 0071 Extraction latch was opened Meaning The latch has been pulled down The blade is not accessible C 8400 0072 Extraction latch was closed Meaning The latch has been closed The blade is inserted into the chassis C 8400 0073 Blade was powered off Meaning The blade is powered off after a latch pull C 8400 0074 Blade was powered on Meaning The blade was powered on after an extraction latch was closed C 8400 0075 Upgrading License for Fault Tolerant capability Meaning The Fault Tolerant license was applied successfully C 8400 0076 Upgrading License for HyperStack tm capability Meaning The HyperStack license was applied successfully C 8
94. one with the same name but different members Action Modify one or both of the zones so that their membership is the same or deactivate one of the active zone sets To connect the two fabrics reset the affected E Ports A1004 0010 Eport Isolating due to Remote switch using same domain ID Meaning An E Port isolated because the remote switch has the same domain ID Action Change the domain ID on one of the switches A1004 0011 Eport Isolating due to Remote switch isolated Meaning An E Port isolated because the remote switch has the same domain ID Action Change the domain ID on one of the switches A1004 0012 Eport Isolating due to ISL Security Meaning A remote switch attempted to log in but was rejected because it failed to satisfy the ISL group membership requirements Action Review the ISL group configuration and make the necessary corrections to include the remote switch as a member 59060 07 D 2 15 2 Event Messages Alarm Events EENENENNNM A1004 0013 Eport Isolating due to all switches incapable of becoming Principal Switch Meaning An E Port isolated because the principal priority on all switches is set to 254 Action Configure one of the switches to be the principal switch by changing the principal priority A1004 0014 Eport Isolating due to TOV mismatch indicated on ELP Meaning An E Port isolated because the R A TOV or E D TOV time out values are different on the two switches
95. or can be 1 55V 2 5V 1 5V ASIC_1 8V 1 25V 1 8V 3 3V CPU 1 8V 5V 12V ASIC 0 1 5V or ASIC 1 1 5V The voltage sensor voltage supply is out of range it is too low 1 55V 2 5V 1 5V ASIC_1 8V 1 25V 1 8V 3 3V CPU 1 8V 5V 12V ASIC 0 1 5V or ASIC 1 1 5V 2 3 2 Event Messages Alarm Events SSS C I OV 9 Alarm Events An alarm event requires action before you can proceed any further The following lists each alarm event ID numbers and message displayed and provides a description of the meaning of the message and recommended action to take A1000 000F The switch is canceling the hotreset try again later Meaning You cannot move forward with the hot reset All applications and switch resources are backing out of the procedure and returning to normal operation Action Ensure that the fabric is stable and that no changes are being made to switch configurations or connections and then try again A1000 001D Hotreset failed and the switch must be reset normally Meaning The hot reset has failed and left the switch in an indeterminate state Action Reset the switch A1000 001E Hotreset failed and the switch is being reset Meaning There was a failure during the hotreset process the switch is being reset normally Action None A1003 000B Failing release of fabric lock held by switch with domain domain D Meaning The local switch is locked because zoning changes are being mad
96. progress Action Wait and try again A1003 0025 Error reading security set Meaning There was a problem handling the activate direct management server command The format of the command was not standard Action Check the security configuration A1003 0028 SFC failure received from remote switch with domain domain_ID Meaning The remote switch given by domain_ID rejected the Staged Fabric Configuration SFC message so the SFC request has failed Action Check the status of the remote switch at the given domain ID There could be an issue with the security configuration or the zoning configuration A1003 0029 No response received from switch with domain ID domain_ID Meaning The remote switch given by domain_ID did not reply to an Acquire Change Authorization ACA message so the ACA request has failed Action Check the status of the remote switch at the given domain ID There could be an issue with the security configuration or the zoning configuration 59060 07 D 2 7 2 Event Messages Alarm Events EENNENNNM A1003 002A No response received from switch with domain ID domain_ID Meaning A Staged Fabric Configuration SFC frame was sent to the switch given by domain_ID but a response was not received Action Check the status of the remote switch at the given domain ID There could be an issue with the security configuration or the zoning configuration A1003 002B No response received from switch
97. receiving power Action None A2002 0001 fan number was removed Meaning A field replaceable fan was removed from the switch Action Reinstall the fan A2002 0002 Fan fan blade failure ALARM SET Meaning A cooling fan has failed Action Replace the fan if it is a customer replaceable unit Otherwise contact your authorized maintenance provider A2002 0003 Fan or power supply flow mismatch ALARM SET Meaning The switch has two cooling fans with opposite air flow directions Action Replace one of the fans with another fan with the correct air flow direction A2003 0001 fan blade inserted ALARM CLEARED Meaning The switch fan blade has been installed and the alarm is cleared Action None A2003 0002 fan_blade OK ALARM CLEARED Meaning The switch fan blade is operational and the alarm is cleared Action None A2003 0003 Fan flow match ALARM CLEARED Meaning The opposing fan air flow condition has been corrected Action None A2004 0001 Secondary cpu blade assuming control of system due to a failure of Primary cpu_blade Meaning Control is transferring from the primary CPU blade to the secondary CPU blade on a QLogic 9000 switch Action Investigate the former primary CPU blade for the cause of the failure 2 46 59060 07 D 2 Event Messages Alarm Events TE a A2004 0002 Secondary cpu blade assuming control of system due to an administrative switchover Meaning Control is
98. restore to clear this error Meaning The configuration area was damaged or a Remake Filesystem was performed from Maintenance mode Action Enter the Config Restore command to clear the error If this does not correct the problem contact your authorized maintenance provider A3014 0001 Blade in slot s ot number set Down due to failure of all AuxPorts Meaning The blade in the named slot has isolated because all auxiliary ports to the cross connect blades have failed Action Contact your authorized maintenance provider A3014 0002 Blade in slot s ot number set Online due to internal failure recovery Meaning The blade in the named slot has recovered at least one auxiliary port to a cross connect blade and is no longer isolated Action None A3014 0003 IOn Blade blade ID set Down due to the configured blade type not matching the installed blade Meaning The I O blade given by blade ID has isolated because the operational blade type does not match the configured blade type Action Change the configured blade type to match the I O blade that is present or insert an I O blade of the configured blade type 2 50 59060 07 D 2 Event Messages Alarm Events TO EE A4000 0001 threshold of value hit rising trigger trigger numberin value second window on port port number ALARM SET Meaning The switch exceeded the specified threshold for the rising trigger in the specified sample window Action Investigate t
99. rithm that is not allowed for this security member s configuration Check the remote device for a possible error condition Reset the port If errors continue disable CHAP for this device if it belongs in the fabric 2 43 2 Event Messages Alarm Events EENNNNNNM A1007 0032 Fabric conditions or configurations do not currently allow for changing fabric binding Meaning An attempt to change the fabric binding setting was rejected due to current fabric binding configuration settings within the active security set Action Check fabric binding settings and the domain IDs of the switches within the fabric Add missing switches to the ISL group of the active security set A1007 0033 Device device WWN failed port binding Meaning A device attempted fabric login FLOGI but that device was not configured in the port binding list for the specified port Action Add the device to the port binding list A1007 0034 Device device wwn failed switch binding Meaning A device attempted fabric login FLOGI but that device was not configured in the switch binding list for the specified switch Action Add the device to the switch binding list A1007 0035 Port taken offline due to switch binding failure following configuration change Meaning A configuration change was made to the switch binding list such that the device s on the port were no longer allowed to be logged in Action Add the devices to the switch bindin
100. rom the zoning database could isolate all switches in the fabric C 8400 0043 Switch Warning clearing the active zoneset may cause fabric isolation Meaning Clearing all zoning definitions from the active zone set could isolate all switches in the fabric 2 56 59060 07 D 2 Event Messages Critical Events TO EEE C 8400 0044 Switch A reset is required since a Power On Self Test POST has never run on these ports Meaning After upgrading ports it may be necessary to reset the switch so that the POST can run on the newly licensed ports C 8400 0045 Switch Upgrading License for 4G capability Meaning Installation of the license key that grants 4 Gbps transmission speed capability to the Fibre Channel ports is in progress C 8400 0046 Switch Upgrading License for multiple ISL capability Meaning The switch has been upgraded to allow for multiple inter switch links C 8400 0047 Switch New licenses are being installed Meaning New licenses are being installed C 8400 0049 Switch The Configuration Wizard from ip address is exiting switch configuration may have changed Meaning Changes made to switch may result in loss of communication with the switch C 8400 004B Switch Attempted to license modes on an unsupported switch type Meaning An attempt was made to install a license key for a feature that is not supported on the switch C 8400 004C Switch Services setup is changing
101. synchronize its time clock with the Network Time Protocol NTP server Action Confirm that the NTP service and NTP client are enabled Confirm that the NTP server IP address is correct and that the server is operating A1005 006E A reset is required to activate this version of firmware Meaning The installed firmware cannot be activated without disrupting I O traffic Action Perform a hard reset A1005 006F Hotreset Vversion gt Vversion is not supported Meaning The installed firmware cannot be activated without disrupting I O traffic Action Perform a hard reset A1005 0070 Hotreset to older firmware version not supported A reset is required to activate this version of firmware Meaning The installed firmware cannot be activated without disrupting I O traffic Action Perform a hard reset A1005 0071 Unable to obtain dynamic IP address falling back to static IP address of address on interface interface Meaning The switch was unable to obtain its IP address from the Dynamic Host Configuration Protocol DHCP server The static IP address will be used Action Investigate the DHCP server A1005 0072 Unable to turn off lasers please power off the switch Meaning Conditions exist that could damage the switch and the switch was unable to turn off the Fiber Channel port lasers Action Power down the switch and contact your authorized maintenance provider A1005 0073 Blade fault fau t reported Me
102. th this switch An HBA has attempted to register its FDMI information with the switch but allowing it to do so would cause the FDMI database to exceed the configured limit I 8200 0301 mserver Port port number Rejecting FDMI request from address FC address on port port number FDMI is configured as disabled Meaning The Fabric Device Management Interface FDMI server on this switch has been disabled so any FDMI requests received by the switch will be rejected I 8300 0004 zoning New Active ZoneSet zone set name Meaning A new zone set has been activated I 8300 0007 zoning Fabric lock held by domain domain D hotreset not permitted Meaning Another switch has acquired our fabric zoning lock a zoning request is about to occur Retry a hot reset after the fabric zoning lock is released I 8300 0008 zoning Processing zoning requests Checkpoint not permitted Meaning Another switch has acquired our fabric zoning lock a zoning request is about to occur Retry a hot reset after the fabric zoning lock is released I 8300 0009 Zoning Reading zoning database Checkpoint not permitted Meaning A change to the fabric zoning database forced a read of the database to occur Retry a hot reset after the read is complete 1 8300 0010 Zoning Removing all inactive zoning objects Meaning All zones that were members of the previously active zone set are being removed from the zoning database 5
103. thentication attempt The port will isolate Action Checks the security configuration on the remote switch to determine the problem A1007 0006 Security Could not validate Authentication Response from port number payload seems to be incorrect Meaning The format of the payload of the response frame does not match what was expected Action Check for errors on the remote side of the link Check the transceiver and cable Update firmware on remote switch A1007 0007 Security Fabric Binding ESA not supported on remote switch and Fabric Binding is enabled failing security checks Meaning Either fabric binding is not enabled on the remote switch or the remote switch does not support security at all Action Check the security configuration on the remote switch A1007 0008 Security ESA Response failure failing security checks Meaning A failure was received during processing of the ESA received frame Either the payload did not match the standard layout or the payload status indicated a reject Action Check for errors on the remote side of the link Check the transceiver and cable Update firmware on the remote switch A1007 0009 Security checks EFMD response failure failing security check Meaning A remote switch rejected a Exchange Fabric Membership Data EFMD frame The port will be isolated Action Check remote switch for the reason that the EFMD frame was rejected It is possible that the FabricBind
104. to release fabric zoning lock because it is held by another switch in the fabric C 8300 000F Zoning Failed to lock fabric lock already held with lock id ock id Meaning The fabric is already locked C 8300 0017 The zoning database has been reset and zoneset zone set deactivated by user user name Meaning The zoning database was reset while a zone set was active The zoning information was cleared and the active zone set was deactivated 59060 07 D 2 53 2 Event Messages Critical Events EEE C 8300 0018 ZoneSet zone_set has been activated by user user_name Meaning A zone set in the zoning database has been activated C 8300 0019 ZoneSet zone_set has been deactivated by user user_name Meaning A zone set in the zoning database has been deactivated C 8300 001A A ZoneSet activation has failed Meaning An attempt to activate a zone set has failed C 8400 0002 Switch The switch is being reset please wait Meaning The switch is being reset C 8400 0003 Switch The switch is being shutdown please wait Meaning The switch is being gracefully shutdown C 8400 0004 Switch The switch is proceeding with a hotreset Meaning Hot reset is in progress C 8400 0005 Switch The switch is now performing a hotreset Meaning Hot reset is in progress C 8400 0006 Switch Admin mode for user user_name was canceled by user user name Meaning Admin
105. ts ls Critical Events Critical events are events that disrupt the administration or operation of the fabric but do not require any action before you can proceed The following lists each critical event and the event id number and message displayed and provides an explanation of the message C 8100 0001 Name Server Port port number Protocol violation from address FC address Meaning There has been a name server protocol violation Contact your authorized maintenance provider C 8300 0006 Zoning Dropping lock held by domain domain D Merge requests outstanding Meaning Another switch has held the fabric zoning lock too long It is being released to accommodate another fabric zoning request C 8300 000A Zoning Fabric Busy failing lock request from domain domain D Meaning Another switch in the fabric has requested the fabric zoning lock from this switch while this switch is processing zoning commands C 8300 000B Zoning Failed to lock fabric lock already held by switch with domain domain ID Meaning Unable to complete the requested zoning command because fabric zoning lock is already held by another switch in the fabric C 8300 000C Zoning Couldn t acquire lock from domain domain 1D Meaning Fabric may be changing couldn t acquire lock Wait for fabric to stabilize try again C 8300 000E Zoning Failing release of fabric lock held by switch with domainz domain ID Meaning Unable
106. umber of frames from the indicated address have been received These frames are from a source that is not zoned with the destination A denial of service entry will be set up to discard these frames Action Investigate the source at the specified Fibre Channel address A1004 0054 Eport Isolating due to Link to self Meaning Two ports on the same switch cannot be connected together Action Disconnect one or both ports A1004 0055 Chassis Interconnect cables misconfigured see configuration guide for optimal setup Meaning Two QLogic 9000 switches are interconnected with HyperStacking cables in a manner that is not supported Action Refer to the Installation Guide for information about how to connect QLogic 9000 switches with HyperStacking cables 2 20 59060 07 D 2 Event Messages Alarm Events ls A1004 0056 Blade compromised due to internal data link failure SET Meaning An I O blade has been compromised due to failure of its internal data link to the CPU blade Action Contact your authorized maintenance provider A1004 0057 Blade no longer compromised due to internal data link failure CLEAR Meaning The I O blade link failure has been resolved Action None A1004 0060 Virtual Lanes configuration change will take effect on next port reset Meaning The virtual lanes configuration does not become active until you reset the port Action Reset the port A1005 0006 Request from WWN device WWN a
107. uting protocol FSPF Action Connect a compatible switch A1004 000A Eport Isolating due to EFP Domain Overlap Meaning An E Port isolated because each fabric has a switch with the same domain ID Action Change the domain ID on one of the conflicting switches A1004 000B Eport Isolating due to Switch Administratively Offline Meaning An E Port isolated because the local switch has been placed offline Action Configure the administrative state to Online to establish the link 2 14 59060 07 D 2 Event Messages Alarm Events ls A1004 000C Eport Isolating due to Domain ID Locked Domain ID unavailable Meaning An E Port isolated because the requested domain ID matches another in the fabric and assigning an alternative is prohibited by the domain ID Lock parameter Action Disable the domain ID lock parameter or reconfigure the domain IDs A1004 000D Eport Isolating due to RDI SW Reject Meaning An E Port isolated because the principal switch rejected the local switch domain ID Action Change the domain ID so that it is unique in the fabric A1004 000E Eport Isolating due to RDI Domain out of Range Meaning An E Port isolated because the principal switch rejected the local switch domain ID as being out of range 1 239 Action Change the domain ID to a valid number A1004 000F Eport Isolating due to Merge Zone Failure Meaning An inter switch link failed because the two active zone sets have a z
108. ve to the administration or oper ation of a fabric and require administrator intervention Alarms are always logged and always displayed on the screen Alarm thresh olds can be defined for certain port errors allowing you to custom ize the point at which an alarm will be generated Critical Describes events that are generally disruptive to the administra tion or operation of the fabric but require no action Warning Describes events that are generally not disruptive to the adminis tration or operation of the fabric but are more important than the informative level events Informative Describes routine events associated with a normal fabric 59060 07 D m 1 Events and Event Logging Displaying Events using the Event Browser EE Displaying Events using the Event Browser Both Enterprise Fabric Suite and QuickTools have an event browser that displays a list of events generated by the switches in the fabric and by the applications themselves Event browser messages are permanently discarded when you close an Enterprise Fabric Suite or QuickTools session however you can save these events to a file on the workstation before you close the session and read the file later with a text editor or browser The information in the event browsers is presented in the following order severity time source type and description of the event The maximum number of entries allowed on a switch is 1 200 Both the Enterprise Fabric Suite
109. vice for a possible error condition Reset the port to retry again If errors continue disable Challenge Handshake Authentication Protocol CHAP for this device if it belongs in the fabric A1007 001D Ignoring RADIUS Server Radius Server invalid IP address configured Meaning A Remote Authentication Dial In Service RADIUS server could not be found at the configured IP address Action Check the RADIUS server or change the configuration to use an IP address for a valid RADIUS server A1007 001F Access reject from RADIUS server P adaress port for device on this port Meaning Security authentication has reached the maximum retry count The port will now isolate Action Check the security configuration A1007 0020 MAX Retry count reached on CHAP Authentication Protocol Reset failing Authentication Meaning A Remote Authentication Dial In Service RADIUS server has rejected a RADIUS authentication request Action Check the configuration on both the switch and on the RADIUS server for incompatibilities A1007 0021 No response to RADIUS access request for device on port port Meaning A configured Remote Authentication Dial In Service RADIUS server did not respond to an authentication request within the timeout period Action Check RADIUS server configuration and the RADIUS server A1007 0022 Invalid response authenticator from RADIUS server P_address port check shared secret Meaning There is a R
110. w Meaning A low voltage blade fault has occurred on a QLogic 9000 switch Action Contact your authorized maintenance provider A3006 0001 000D Blade fault value LOW PS 1 2V 2 The value V voltage supply is out of range it is too low Meaning A low voltage blade fault has occurred on an for IBM BladeCenter Module Action Contact your authorized maintenance provider A3006 0001 000E Blade fault value LOW PS 1V The value V voltage supply is out of range it is too low Meaning A low voltage blade fault has occurred on IBM BladeCenter Module Action Contact your authorized maintenance provider A3007 0001 000C value voltage sensor shows valueV ALARM CLEAR Meaning The out of range voltage condition on a QLogic 5000 series switch has cleared Action None 59060 07 D 2 49 2 Event Messages Alarm Events E A3007 0001 000C Blade fault blade_fault CLEARED Meaning The high or low voltage IBM BladeCenter Module blade fault has cleared Action None A3007 0001 000D Blade fault value NORMAL PS 1 2V 2 CLEARED Meaning The high or low voltage IBM BladeCenter Module blade fault has cleared Action None A3007 0001 000E Blade fault value NORMAL PS 1V CLEARED Meaning The high or low voltage IBM BladeCenter Module blade fault has cleared Action None A3008 0000 The configuration area was damaged or a Remake Filesystem was performed from PROM mode You must perform a config
111. witch from the display I 8F00 0009 Link Added Meaning The application fabric discovery process has discovered a new inter switch link ISL in the fabric 59060 07 D 2 77 2 Event Messages Informative Events E I 8F00 000A Link Removed Meaning A link has been removed from the display This is either because the fabric discovery process has discovered that the link is no longer in the fabric or because the user has deleted the link manually I 8F00 000B Login Changed Meaning The login to the fabric has changed The description field will show the reason for the change in the login 1 8F00 000C Fabric Status status Meaning The severity of the fabric status has changed The description field will show the reason for fabric status I 8F00 000D Switch Status status Meaning The severity of the switch status has changed The description field will show the reason for the switch status I 8F00 000E Link Status status Meaning The severity of the link status has changed The description field will show the reason for link status 2 78 59060 07 D XX Corporate Headquarters QLogic Corporation 26650 Aliso Viejo Parkway Aliso Viejo CA 92656 949 389 6000 www qlogic com QLOGIC International Offices UK Ireland Germany France India Japan China Hong Kong Singapore Taiwan 2011 QLogic Corporation Specifications are subject to change without notice All rights reserved worldwide QLogic the
112. y alarms If this alarm persists contact your authorized maintenance provider A1005 009C IPSec configuration error Association assocation name error description Meaning An error occurred affecting the specified association while saving the IP Security configuration The association has not been applied to the active database Action Redo modifications to the association and save it A1005 009D IPSec configuration error Policy policy name reason Meaning An error occurred affecting the specified policy while saving the IP Security configuration The policy has not been applied to the active database Action Redo modifications to the policy and save it A1005 0101 ipv6 duplicate address detected Meaning Another IP version 6 system on the local network is using the same address as this switch Action If the discovery method is static assign a different IP version 6 address or disconnect the device that is using the same address 59060 07 D 2 31 2 Event Messages Alarm Events EENNNNM A1005 0106 Fabric translation setup error PLOGI from c id to fc id OX ID ox id rejected Meaning A Port Login PLOGI from one transparent route endpoint to another was rejected because of hardware resource limitations on the TR Port or the F FL port involved in the mapping Action If there are 32 active transparent routes on the TR Port reduce the number of mappings on that port or use a different TR port I