1. VTrak Setup with Embedded WebPAM Log in to WebPAM 1 Launch your Browser 2 Inthe Browser address field type in the IP address of the VTrak Management port Use the IP address you obtained in Step 7 see page 11 Note that the IP address shown below is only an example The IP address you type into your browser will be different Regular Connection e WebPAM uses an HTTP connection http Enter the VTrak s Management Port IP address 192 168 10 148 Together your entry looks like this http 192 168 10 148 Secure Connection e WebPAM uses a secure HTTP connection https e Enter the VTrak s Management Port IP address 192 168 10 148 Together your entry looks like this https 192 168 10 148 Note Whether you select a regular or a secure connection your login to WebPAM and your user password are always secure VTrak M310p M210p Quick Start Guide 4 Promise Advanced Storage Manager Login Microsoft Internet Explorer File Edit View Favorites Tools Help Back x Ce D search Favorites 2 amp amp 7 wif cE Address http 192 168 10 148 Bo ims a PROMISE Language Contactus TECHNOLOGY INC 2005 Promise Technology Inc All rights reserved Internet When the opening screen appears type administrator in the User Name field and type password in the Password field The User Nam
2. e Power FRU and Logical Drive LEDs display green continuously e Fibre Channel iSCSI SCSI LEDs flash green if there is activity on that channel There are two LEDs on each Drive Carrier They report the presence of power and a disk drive and the current condition of the drive Disk Status Power Activity Figure 8 VTrak M310p M210p disk carrier LEDs After a few moments the Power Activity should display Green If there is no disk drive in the carrier the Disk Status LED and the Power Activity LED will remain dark Step 7 Set IP Address with CLI or CLU VTrak has a Command Line Interface CLI to manage all of its functions including customization A subset of the CLI is the Command Line Utility CLU a user level interface that manages your VTrak via your PC s terminal emulation program such as Microsoft HyperTerminal You will use the CLU to assign an IP address to the VTrak for WebPAM 1 Change your terminal emulation program settings to match the following e Bits per second 115200 e Data bits 8 e Parity None e Stop bits 1 e Flow control none Start your PC s terminal VT100 or ANSI emulation program Press Enter once to launch the CLI At the Login prompt type administrator and press Enter At the Password prompt type password and press Enter akon Step 7 Set IP Address with CLI or CLU CLI At this point you are in the CLI You can continue using the CLI to make network setti
3. Predictive Data Migration PDM scans the bad sector remapping table of the disk drives assigned to a logical drive When the table fills to a specified percentage of its capacity PDM triggers a migration of data from the suspect drive the disk drive with the bad sectors to a spare disk drive Highlight physical drives you want in the disk array from the Available list and press the gt gt button to move them to the Selected list You can also double click them to move them When you are done click the Next button 20 Step 8 VTrak Setup with Embedded WebPAM ET GB Y Maximum 108 9668 64KB 512Bytes Read head E E E E WriteBack Free Capacity a Alias RADLevel Capacity Stripe Sector ReadPolicy Write Policy _ There is no new logical de Ul There is no new logical drive On this screen you will specify your logical drives Specify one logical drive at a time until the full capacity of the disk array is allocated 5 6 Enter an Alias name for the first logical drive Choose a RAID level from the dropdown menu The choice of RAID levels depends on the number of physical drives you selected Specify a Capacity and the unit of measure MB GB TB This value will be the data capacity of the logical drive If you specify less than disk array s maximum capacity the remainder is available for additional logical drives Specify a Stripe
4. Start Guide Alias RAIDLevel Capacity Stripe Sector ReadPolicy Write Policy RAIDO 1 LDO 5068 64KB 512Bytes ReadAhead WriteBack 2 LD1 25GB 64KB 512Bytes ReadAhead WriteBack 3 LD2 RAIDO 25GB 64KB Si2Eytes Readahead WriteBack 13 When you have finished specifying logical drives click the Next button 24 Step 8 VTrak Setup with Embedded WebPAM Information Create Delete Advanced Configuration Step 3 Summary Disk Array Alias DAO Number of Physical Drives 3 Physical Drive IDs 131415 Configurable Capacity 108 9668 Free Capacity 8 96GB Media Patrol Enabled PDM Enabled Hew Logical Drives Alias RAID Level Capacity Stripe Sector Read Policy Write Policy 1 LDO RAIDO 50GB 64KB 512Bytes ReadAhead VVvriteBack 2 LD1 RAIDO 25GB 64KB 512Bytes Read head WriteBack 3 LD2 RAIDO 25GB 64KB 512Bytes ReadAhead WriteBack EA The proposed disk array appears with the logical drive s you specified 14 If you agree with the proposed disk array and logical drive s click the Submit button If you disagree click the Back button and make changes as needed Additional Logical Drives If you want to create additional logical drives and there is unused space on the current disk array click on the Disk Array amp icon and click on the Create LD tab You will go to Disk Array Advanced Creation see page 19 If the current disk array is fu
5. gt __ Controller Heartbeat Figure 1 VTrak M310p Front View M210p is similar Power Supply 1 Cooling Unit 1 Cooling Unit 2 Power Supply 2 RAID Controller Figure 2 VTrak M310p M210p Rear View VTrak M310p M210p Quick Start Guide Step 2 Mount VTrak in a Rack The VTrak M310p M210p subsystem installs directly to the rack with or without using the optional mounting rails Refer to Chapter 2 of the VTrak Product Manual on the software CD for instructions on installing the rails and mounting your VTrak Step 3 Install Disk Drives You can populate the VTrak with 1 5 GB or 3 0 GB SATA drives Refer to Chapter 7 of the VTrak Product Manual on the software CD for the number of drives needed for each RAID configuration Install all of the drive carriers into the VTrak enclosure to ensure proper airflow even if you do not populate all the carriers with disk drives If you use different size disk drives in the same logical drive the total size of the logical drive will equal the size of the smallest disk drive times the number of drives Refer to Chapter 2 of the VTrak Product Manual on the software CD for diagrams showing how the drive slots are numbered Caution Use only the counter sink screws supplied with the VTrak Use of other types of screws can damage the adjacent drives SATA Drive Mounting Holes
6. size from the dropdown menu 8 16 32 64 128 256 512 KB and 1 MB are available 64 KB is the default Specify a Sector size from the dropdown menu 512 Bytes 1 2 and 4 KB are available 512 Bytes is the default 21 VTrak M310p M210p Quick Start Guide 10 Choose a Read Cache policy e __ ReadCache e ReadAhead e No Cache 11 Choose a Write Cache policy e WriteThru e WriteBack 12 Click the Update button E Fo GB Maximum 58 9668 64KB F 512Bytes WhiteBack E ReadShead M a Alas RADLevel Capaciy Swipe Sector Rea Poley Write Pole n ow RADO So 64KB sine Readanead WiteBack When you click the Update button WebPAM sets up one logical drive and adds it to the New Logical Drive lists at the bottom of the window To create another logical drive repeat steps 5 through 12 above 22 Step 8 VTrak Setup with Embedded WebPAM M Maximum 58 9568 512Bytes ReadAhead WhriteBack Alias RA DLevel Capacity Stripe Sector Read Policy Write Policy 1 LDO RAIDO 50GB 64KB 512Bytes ReadAhead WriteBack 2 LD1 RAIDO f 5065 64KB 512Bytes ReadAhead iteBack If you want to change a logical drive setting click on the logical drive at the bottom of the window The entry and the capacity usage are highlighted Make your changes to the parameters and click the Update button 23 VTrak M310p M210p Quick
7. your user name and password and click Login and WebPAM will establish a new connection I can access the VTrak over my company s intranet But can t access it from an outside Internet connection How do make the Internet connection work This condition is not related to VTrak but is due to your firewall and network connection protocol Contact your MIS Administrator With other Promise VTraks used the Server s IP address in WebPAM to connect with the RAID subsystem Why is this VTrak M310p M210p different VTrak M310p M210p has the server software embedded With the M310p M210p you point your browser directly to the VTrak rather than a server Also with M310p M210p you do not have to create a subsystem because the subsystem already exists Why can a RAID 1 logical drive on VTrak consist of only two disk drives On VTrak RAID 1 logical drives work in mirrored physical drive pairs You could create up to seven RAID 1 logical drives Or you can create a single RAID 10 logical drive with data mirroring and up to 12 physical drives If you have an odd number of drives but still want data mirroring use RAID 1E See the V7rak Product Manual on the software CD for more information on the number of physical drives you can use for each RAID level Are logical drives on VTrak limited to 2 199 terabytes No But verify that your operating system supports logical drives over 2 199 TB Also for the operating system to recogniz
8. 64KB 51 2Bytes ReadAhead WhriteBack v Physical Drive IDs There is no hot spare drive Follow these steps to create a new disk array Check the boxes to select any one or a combination of Redundancy The array will remain available if a physical drive fails Capacity The greatest possible amount of data capacity Performance The highest possible read write speed Spare Drive A hot spare drive In the Number of Logical Drives field enter the number of logical drives you want to make from this disk array The maximum possible number of logical drives appears to the right of this field 18 Step 8 VTrak Setup with Embedded WebPAM 3 From the Application Type menu select an application that best describes your intended use for this disk array File Server Video Stream Transaction Data Transaction Log Other 4 Click the Update button Or check the Automatic Update box and updates will occur automatically The following parameters display Disk Arrays The number of physical drives in the disk array their ID numbers configurable capacity and the number of logical drives to be created Logical Drives The ID number of the logical drive s their RAID level capacity and stripe size Spare Drives The physical drive ID number of the dedicated hot spare assigned to this disk array If you accept these parameters proceed to the next step If you do NOT accept the
9. PROMISE TECHNOLOGY INC VIRAK M3100 M2100 ersion 2006 Promise Technology Inc All Rights Reserved VTrak M310p M210p Quick Start Guide VTrak M310p M210p Task List Step 1 Unpack the VTrak below Step 2 Mount VTrak in a Rack page 4 Step 3 Install Disk Drives page 4 Step 4 Network and Data Cable Connections page 6 Step 5 Set Up Serial Cable Connections page 7 Step 6 Connect the Power page 7 Step 7 Set IP Address with CLI or CLU page 8 Step 8 VTrak Setup with Embedded WebPAM page 12 Step 1 Unpack the VTrak The VTrak box contains the following items VTrak Unit Screws for disk drives e Quick Start Guide 52 for M310p 36 for M210p Null Modem Cable 1 0m External VHDCI SCSI cable 2 for M310p 1 for M21 0p gt gt including 4 spares 1 5m 4 9 ft Power cords 2 for US and 2 for Europe Mounting rail sets 1 pair e CD with SNMP files Product Manual and Quick Start Guide Warning The electronic components within the VTrak disk array are sensitive to damage from Electro Static Discharge ESD Observe appropriate precautions at all times when handling the VTrak or its subassemblies Important Use the following categories of network cables with VTrak Cat 6 preferred Cat5 minimum Step 1 Unpack the VTrak FRU Status Disk Array Status RAID Controller Activity Reserved _
10. e and Password are case sensitive Click the Login button After sign in the WebPAM opening screen appears next page If there are any unconfigured physical drives in the enclosure the Array Configuration menu will also appear see page 16 Important As soon as possible assign the Administrator s password Make the change under User Management Each user you create will have his her own login ID and password Note Make a Bookmark Netscape Navigator or set a Favorite Internet Explorer of the Login Screen so you can access it easily next time 14 Step 8 VTrak Setup with Embedded WebPAM 2 Promise Advanced Storage Manager Microsoft Internet Explorer File Edit View Favorites Tools Help Home User administrator Welcome to Promise Advanced Storage Manager ER 192 168 10 148 VTrek y min Promise Web Based Advanced Storage Manager is B Administrative Tools A an easy to use software designed to simplify iSCSI EL Controllers storage management Specifically designed for E Enclosures Promise VTrak subsystems WebPAM can s Disk Arrays 3 configure manage or monitor Promise VTrak gt products remotely from a web browser from amp a Spare Drives anywhere in the world amp B Logical Drive Summary Quick Link 2004 Promise Technology Inc All rights reserved Version 0 03 0000 41 Build Date Mar 25 2005 Internet The first time
11. e are no disk arrays or logical drives yet Array Configuration 4 unconfigured physical drives in the subsystem Heip Information Create a Delete Configuration Method Automatic Configuration User has no choice Only one logical drive is created O Express Configuration User has some choices All logical drives are the same O Advanced Configuration User has full selection Each logical drive can be different resa EXI es There are three options Automatic Express and Advanced Select one and click the Next button Or select one from the dropdown menu on the Create tab Automatic The Disk Array Automatic Creation option enables you to create a new disk array following a default set of parameters One logical drive will be made automatically when you create the disk array 16 Step 8 VTrak Setup with Embedded WebPAM The number of unconfigured physical drives available will determine the RAID level of the disk array and whether a spare drive is created Automatic Configuration EC Information Create Delete Disk Array 1 Number of Physical Drives 4 Physical Drive IDs 1315145 Total Configurable Capacity 134 11GB Number of Logical Drives 1 Logical Drives RAID Level Capacity Stripe Sector Read Policy Write Policy 1 RAIDS 100 58GB 64KB 512Bytes ReadAhead WriteBack Spare Drives Physical Drive IDs Spare Type There is no hot spare drive oe
12. e the full capacity of logical drives over 2 199 TB you must specify a sector size of 1 KB or larger when you create the logical drive See Chapter 7 of the VTrak Product Manual on the software CD for more information have two UltraTraks and use WebPAM to monitor them Can use my existing WebPAM setup to monitor the VTraks also No Use the WebPAM embedded with the VTrak M310p M210p 27 VTrak M310p M210p Quick Start Guide How can I be sure everything is working OK on the VTrak Locally The VTrak enclosure has LEDs on the front to monitor the status of power field replaceable units FRUs and logical drives When these are green VTrak is functioning normally Remotely Check the Tree Icons in WebPAM If there are no yellow or red warning icons displayed VTrak is functioning normally What happens if a logical drive goes critical On the front of VTrak the logical drive LED turns amber and an audible alarm sounds This condition is described in Chapter 4 of the VTrak Product Manual on the software CD Can VTrak run using just one power supply Yes it is possible to run VTrak on a single power supply There are two power supplies so that VTrak will continue running if one of the power supply fails But deliberately leaving one power supply off negates this advantage In addition leaving one power supply off reduces air flow through the VTrak enclosure and can contribute to overheating Always switch on both powe
13. in the reserve sector of each physical drive VTrak M310p M210p use the industry standard DDF and have a metadata to DDF conversion feature To use the conversion feature you must restart the VTrak M310p M210p after installing disk drives from an older system Note that if you move the disk drives from the VTrak M310p M210p to the older subsystems they will not recognize your disk array or logical drive Can I use my existing SCSI card with VTrak M310p M210p Yes For best performance results use an Ultra320 SCSI card How can tell when the VTrak has fully booted During the VTrak power up process the Power FRU Status and Logical Drive Status LEDs will light up When the Logical Drive Status LEDs light up the VTrak is fully booted See pages 7 and 8 Why does VTrak come with a Command Line Utility First to assign your VTrak an IP address in order for the WebPAM management software to connect to it Second in the event of a network failure you can still access the VTrak Third some users prefer the Command Line Utility 26 Frequently Asked Questions My WebPAM connection was working OK But later on it timed out What do I do now The network condition can time out for several reasons When an open connection has no action for a specific amount of time the Administrator can change it the connection times out automatically for security reasons When you attempt to use WebPAM it returns to the login screen Enter
14. lly allocated use additional physical drives to create a new disk array Click on the Disk Arrays B icon then select Automatic Express or Advanced from the Create tab dropdown menu see page 16 Log out of WebPAM There are two ways to log out of WebPAM e Close your browser window e Click Logout on the WebPAM banner below Language View Storage Network Contact Us x Help Clicking Logout brings you back to the Login Screen After logging out you must enter your user name and password in order to log in again 25 VTrak M310p M210p Quick Start Guide Internet Connection using WebPAM The above instructions cover connections between VTrak and your company network It is also possible to connect to a VTrak from the Internet Your MIS Administrator can tell you how to access your network from outside the firewall Once you are logged onto the network you can access the VTrak using its IP address While only a SCSI capable PC can read and write data to the logical drives on the VTrak other PCs can monitor the VTrak from virtually any location Frequently Asked Questions What kind of disk drives can use with VTrak VTrak supports 1 5 and 3 0 Gb s Serial ATA disk drives Can I take the disk drives from my UltraTrak put them into the VTrak and keep my disk array or logical drive intact Yes UltraTraks except for JB4000 and early VTrak subsystems used a proprietary method of disk metadata stored
15. logy Europe B V Science Park Eindhoven 5542 5692 EL Son The Netherlands support de promise emea com Fax Technical Support 49 0 2 31 56 76 48 29 Attn Technical Support Phone Technical Support 49 0 2 31 56 76 48 10 If you wish to write us for support Promise Technology Germany Europaplatz 9 44269 Dortmund Germany Italy E mail Support support it promise emea com Fax Support 0039 06 367 12400 Attn Technical Support Phone Support 0039 06 367 12626 If you wish to write us for support Promise Technology Italy Piazza del Popolo 18 00187 Roma Italia 29 VTrak M310p M210p Quick Start Guide Taiwan E mail Support support promise com tw Fax Support 886 3 578 2390 Attn Technical Support Phone Support 886 3 578 2395 ext 8811 If you wish to write us for Promise Technology Inc support 2F No 30 Industry E Rd IX Science based Industrial Park Hsinchu Taiwan R O C China E mail Support support china promise com Fax Support 86 10 8857 8015 Attn Technical Support Phone Support 86 10 8857 8085 8095 If you wish to write us for Promise Technology China support Room 1205 Tower 3 Webok Time Center No 17 South Zhong Guan Cun Street Hai Dian District Beijing 100081 China Caution There is a risk of explosion if the battery is replaced by the incorrect type e Dispose of used batteries according to the instructions that acc
16. ne of the VTrak s SCSI channels To use the internal termination feature attach the SCSI cable to the In connector An external terminator is not required for this arrangement If you plan to connect multiple VTraks on a SCSI chain connect the other side of the same SCSI channel on the first VTrak to a SCSI channel on the second VTrak See Chapters 4 or 5 of the VTrak Product Manual on the software CD for more information Step 5 Set Up Serial Cable Connections Step 5 Set Up Serial Cable Connections The RS 232 Serial connection enables the Command Line Utility CLU on your PC to monitor and control VTrak DB 9 Serial Connector CONOLE Mgmt o gt 2 Out Figure 6 Serial connector for VTrak M310p M210p Step 6 Connect the Power Plug the power cords and switch on both power supplies on When the power is switched on the LEDs on the front of the VTrak will light up Power _ a FRU Status Logical Drive Status a RAID Controller Activity Reserved Controller Heartbeat Figure 7 VTrak M310p M210p front panel LED display When boot up is finished and the VTrak is functioning normally VTrak M310p M210p Quick Start Guide e Controller Heartbeat LED blinks green seven times in three seconds goes dark for six seconds then repeats the blink pattern
17. ngs or you can switch to the CLU e CLI below e CLU page 10 Type the following string to set the Management Port IP address and other settings then press Enter administrator cli gt net a mod t mgmt s primaryip 192 168 10 87 primaryipmask 255 255 255 0 gateway 192 168 10 3 In the above example the IP addresses and subnet mask are included as examples only Your values will be different If you prefer to let your DHCP server assign the IP address type the following string then press Enter administrator cli gt net a mod t mgmt s dhcp enable To verify the settings type net and press Enter administrator cli gt net 1 1 Mgmt 192 168 10 87 255 255 255 0 192 168 10 3 Up This completes the Management port setup Go to Step 8 VTrak Setup with Embedded WebPAM on page 12 To see the full set of CLI commands at the admin cli gt prompt type help and press Enter VTrak M310p M210p Quick Start Guide CLU 1 Atthe admin cli prompt type menu and press Enter The CLU main menu appears Subsystem Management Physical Drive Management Disk Array Management Logical Drive Management Network Management Fibre Channel Management Background Activity Event Viewer Additional Info and Management Buzzer Return to CLI urn CTRL E Help CTRL E Help 2 With Quick Setup highlighted press Enter The first Quick Setup screen enables you to make Date and Time settings System Date and Time Sy
18. ompany the battery
19. r supplies Contact Technical Support Promise Technical Support provides several support options for Promise users to access information and updates We encourage you to use one of our electronic services which provide product information updates for the most efficient service and support If you decide to contact us please have the following information available Product model and serial number BIOS firmware and driver version numbers A description of the problem situation System configuration information including motherboard and CPU type hard drive model s SATA ATA ATAPI drives amp devices and other controllers Technical Support Services Promise Online Web Site http www promise com support technical documents drivers utilities etc Promise Online eSupport https support promise com support online request form 28 Contact Technical Support United States E mail Support support promise com Fax Support 408 228 1097 Atin Technical Support Phone Support 408 228 1400 option 4 If you wish to write us for support Europe Africa Middle East E mail Support Promise Technology Inc 580 Cottonwood Drive Milpitas CA 95035 USA support promise emea com Fax Support 31 0 40 256 9463 Attn Technical Support Phone Support 31 0 40 235 2600 If you wish to write us for support Germany E mail Support Promise Techno
20. re Toron When you choose the Automatic option the following parameters display e Disk Arrays The number of physical drives in the disk array their ID numbers configurable capacity and the number of logical drives to be created e Logical Drives The ID number of the logical drive s their RAID level capacity and stripe size e Spare Drives The physical drive ID number of the dedicated hot spare assigned to this disk array If you accept these parameters click the Submit button The new disk array appears in the Disk Array List on the Information tab If you do NOT accept these parameters use the Express below or Advanced page 19 option to create your disk array Express The Disk Array Express Creation option enables you to choose the parameters for a new disk array by specifying the characteristics you want With this method you can create multiple logical drives at the same time you create your disk array However all of the logical drives will be the same size and RAID level If you prefer to specify the parameters directly use the Advanced option to create your disk array 17 VTrak M310p M210p Quick Start Guide If you are uncertain about choosing parameters for your disk array use the Automatic option 1315145 Total Configurable Capacity 134 11GB Number of Logical Drives 1 RAID Level Capacity Stripe Sector Read Policy Write Policy RAIDO 134 11GB
21. rrent Management Port IP are displayed above Record the information on this screen Press the spacebar to toggle DHCP back to Enable qi VTrak M310p M210p Quick Start Guide 5 Press Ctrl A to save these settings and move to the RAID configuration screen To make Management Port settings manually oa amp D gt 7 Press the arrow keys to highlight DHCP Press the spacebar to toggle to Disabled Press the arrow keys to highlight P Address Press the backspace key to erase the current IP Address Type the new IP Address Follow the same procedure to specify the Subnet Mask Gateway IP Address and DNS Server IP Address If you do not have a DNS server skip the DNS Server IP address Press Ctrl A to save these settings Exit the CLU 1 2 Highlight Skip the Step and Finish and press Enter Highlight Return to CLI and press Enter This completes the Management port setup Go to Step 8 VTrak Setup with Embedded WebPAM on page 12 Step 8 VTrak Setup with Embedded WebPAM Note You can also use the CLU to create disk arrays and logical drives See Chapter 5 of the VTrak Product Manual on the software CD for more information Set up with WebPAM consists of the following Log in to WebPAM below Language Selection page 16 Create a Disk Array page 16 Additional Logical Drives page 25 Log out of WebPAM page 25 Internet Connection using WebPAM page 26 Step 8
22. se parameters review and modify your selections in the previous steps 5 When you are done click the Submit button The new disk array appears in the Disk Array List on the Information tab Advanced The Disk Array Advanced Creation option enables you to directly specify all parameters for a new disk array If you select less than the total available capacity for the first logical drive you can use the remaining space to create additional logical drives An explanation of the choices you will make while using the Advanced option to create your disk array is included in Chapter 7 of the VTrak Product Manual on the software CD If you are uncertain about choosing parameters for your disk array use the Express or Automatic option to create your disk array 19 VTrak M310p M210p Quick Start Guide Create Disk Array Information Create Delete Advanced Configuration Step 1 Disk Array Creation Disk Array Alias pao Media Patrol Enabled PDM Enabled Physical Drives Available Selected D13 73 57GB Ge ID14 36 32GB ID15 73 57GB EI To create a new disk array le 2 Enter a name for the disk array in the field provided Check the box to enable the following features Media Patrol A routine maintenance procedure that checks the magnetic media on each disk drive Media Patrol is concerned with the condition of the media itself not the data recorded on the media PDM
23. stem Date yyyy mm dd 2005 03 31 System Time hh mm ss 16 27 41 Save Settings and Continue Restore Settings CTRL R Skip to Next Step Return to Main Menu Press the arrow keys to highlight System Date Press the backspace key to erase the current date Type the new date PO DE Follow the same procedure to set the System Time 10 Step 7 Set IP Address with CLI or CLU 5 Press Ctrl A to save these settings and move to the Management Port configuration screen Management Port Port ID PL IP Type Port Status Enabled MAC Address Link Status Up Max Supported Speed Enabled Save Settings and Continue CTRL A Restore Settings CTRL R Skip to Next Step Return to Previous Step IPu4 00 00 00 00 00 00 1000Mbps By default DHCP is enabled on VTrak above To set Management Port settings manually or to view the current settings you must disable DHCP To view the current Management Port settings 1 2 3 4 Press the arrow keys to highlight DHCP Press the spacebar to toggle to Disabled Port ID W IP Type Port Status Enabled HAC Address Link Status Up Max Supported Speed DHCP Disabled 92 168 10 112 Subnet Mask 299 299 299 0 Gateway IP Address 192 168 10 1 DNS Server IP Address 192 168 1 3 Save Settings and Continue CTRL A Restore Settings CTRL R Skip to Next Step Return to Previous Step IPu4 00 00 00 00 00 00 1000Mbps The cu
24. t Jo OJOJ 00 SATA Drive Mounting Holes Figure 3 VTrak M310p M210p drive carrier mounting holes Step 3 Install Disk Drives Figure 4 SATA Disk Drives mount at the front of the carrier Note Unlike other VTrak models the M310p and M210p do not support Parallel ATA disk drives There is no PATA to SATA adapter available for these models VTrak M310p M210p Quick Start Guide Step 4 Network and Data Cable Connections ee spessa Network Switch O Management Port In connector SCSI Channel 1 of2 NIC SCSI HBA Card PC Server Figure 5 VTrak M310p M210p DAS connections This arrangement requires e A network switch e A network interface card NIC in the PC A SCSI HBA card in the PC e A SCSI cable that fits your HBA card and has a VHDCI connector to fit the VTrak SCSI channel VTrak s SCSI connectors are bi directional However the internal termination feature works only on the Out connector Internal termination is set to Automatic by default Connect the PC s standard NIC and VTrak s Management Port to your network switch to establish the management path Connect a SCSI cable to the PC s SCSI HBA card and o
25. you log in to WebPAM there will be no Users except for administrator There will be no disk arrays or logical drives Home User admin Logged in User L a ems EB subsystem 192 168 10 148 VTre Subsystem IP address Administrative Toos lt _ Administration Tools Q User Management lt t User Management By Network Management lt amp Network Management LE SCSI Management amp SCS Management M storage Services Storage Services Gy Software Management amp Software Management EM Controllers Controller Group amp enclosures Enclosure Group E Disk arrays Disk Array Group er Spare Drives Spare Drive Group amp Logical Drive Summary lt Logical Drive Summary Use the Tree to navigate to the various functions of WebPAM Click on an item in the Tree to display it in the window 15 VTrak M310p M210p Quick Start Guide Language Selection WebPAM displays in English German French Italian Japanese Chinese Traditional Chinese Simple and Korean 1 Click on Language in the WebPAM Header The language list appears in the Header 2 Click on the language you prefer The WebPAM user interface will display in the selected language Create a Disk Array Click on the Disk Arrays E amp icon The Array Configuration menu appears Since this VTrak is newly activated ther
Download Pdf Manuals
Related Search
Related Contents
Aire Acondicionado Manual del usuario 9820 General Purpose Indicator Exercices. LabWindows/CVI Programmer Reference Manual Flatbed Scanner Unit 201 Manual del Usuario 取扱説明書 - Panasonic Palm PERFECT PASSENGER + ZIRE 31 COmmENt DEVENir COOL DrÔLE Et stYLé Philips Sync & Charge Cable DLC2407BLK Copyright © All rights reserved.