Home
Polycom RMX 2000 Computer Drive User Manual
Contents
1. Polycom RMX 2000 Hardware Guide Version POLYCOM Copyright 2008 Polycom Inc All Rights Reserved Catalog No DOC2184B Version 2 0 2 Proprietary and Confidential The information contained herein is the sole intellectual property of Polycom Inc No distribution reproduction or unauthorized use of these materials is permitted without the expressed written consent of Polycom Inc Information contained herein is subject to change without notice and does not represent commitment of any type on the part of Polycom Inc Polycom and Accord are registered trademarks of Polycom Inc Notice While reasonable effort was made to ensure that the information in this document was complete and accurate at the time of printing Polycom Inc cannot assume responsibility for any errors Changes and or corrections to the information contained in this document may be incorporated into future issues Portions aspects and or features of this product are protected under United States Patent Law in accordance with the claims of United States Patent No US 6 300 973 US 6 496 216 US 6 757 005 US 6 760 750 and US 7 054 620 PATENT PENDING Regulatory Notices United States Federal Communication Commission FCC Part 15 Class A Statement This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules Test limits are designed to provide reasonable protection against harmful i
2. Module 10 Turn ON the RMX 2000 Polycom RMX 2000 Hardware Guide Replacing the Power Supply Drawer A single supply unit powers the RMX 2000 Use the following procedure to replace a Power Supply 1 2 3 Ensure that power switch to the RMX 2000 is turned OFF O Unscrew the captive screws on the front panel of the RMX 2000 that secure the Power Supply Use the metal ejector levers to pull the Power Supply Module out of its slot in the Backplane Carefully slide the Power Supply Module out through the front panel Po LYC Slide in the replacement Power Supply Module Push the Power Supply Module firmly into the Backplane making sure it is properly seated in its slot Ensure that the metal ejector levers are fully retracted into their housings Tighten the captive screws on the front panel of the RMX 2000 that secure the Power Supply Module Turn ON the RMX 2000 1 21 Chapter 1 Hardware Description Replacing the Fan Drawer C Three fans are mounted in the Fan Drawer where the airflow is from right to left Should one of these fans fail as indicated by a Fan LED you are required to replace the fan drawer 1 Unscrew the captive screws on the front panel of the RMX 2000 that secure the Fan Drawer 2 Use the metal ejector levers to pull the Fan Drawer out of its slot in the Backplane 3 Carefully slide the Fan Drawer out through the front panel Warning The Fan drawer can be replaced when
3. PSTN New hardware technologies Telco grade high availability redundancy on line upgrading and dynamic resource allocation Easy integration of conference elements into external network management Enhanced Continuous Presence multi image video IVR Interactive Voice Response module 1 1 Chapter 1 Hardware Description RMX 2000 Specifications Table 1 1 Polycom RMX 2000 Specifications Height 3U 13 28 cm IP Protocols G 711 G 722 G722 1 G729A G 723 1 Siren14 Network Interfaces IP ISDN PSTN and LAN H 323 PSTN LAN and SIP Power Supply AC Input 100 240 VAC 4 2 AMP 50 60 Hz Power Consumption AC Maximum Power AC Voltage up to 7 AMP at 110 VAC and 4 AMP consumption 220 VAC protected by a 10 Amp circuit breaker Environment 0 40 C 22 104 30 70 C 40 158 F 15 90 no condensing Operating ESD 1 2 Polycom RMX 2000 Hardware Guide Site Requirements This section describes the requirements your site must meet for safe installation and operation of the system Safety Requirements For your protection please read these safety instructions completely before operating the equipment Look carefully for potential hazards in your work area moist floors ungrounded power cables frayed power cords missing safety grounds and so forth Locate the main circuit breaker within the room Locate the emergency power OFF switch within the room Never assume that power is
4. board Inan RMX witha single MPM board the RTM ISDN card must be installed in the rear panel slot on the same level as the MPM board e Inan RMX with two MPM boards the RTM ISDN card can be installed in either of the two rear panel card slots Each RTM ISDN card includes the following connections e 12 E1 T1 PRI lines available for connecting 7 E1 and 9 T1 PRI lines e 1LAN port LAN amp LEDs E1 T1 connections LAN 1 PRH PRI2 PR PRIA PRIS PRIG PRIT PRIS PRIS PRHO PRI PRII2 o 0 Co Ao A H S LED Figure 1 3 RMX 2000 RTM ISDN Rear Panel Layout The RTM ISDN card supports 200 participants regardless of whether the spans are T1 or E1 1 9 Chapter 1 Hardware Description ISDN PSTN Clock Source Each RTM ISDN card has its own primary and secondary clock source The first span to synchronize becomes the primary clock source and the second span to synchronize becomes the secondary clock source This clock is used to synchronize ISDN spans only it is not the system clock A single clock source triggers an alarm that can be turned off by setting the appropriate flag in the system configuration Polycom RMX 2000 Hardware Guide Cables Connected to the RTM IP amp ISDN Boards All external connectors are located on the rear panel RTMISDN u au m a aoa RTM IP Off On Power E1 T1 Connection switch Cable LAN 2 Connection Figure 1 4 RMX 2000 Rear Panel View with Cables es Do not remove
5. disconnected from a circuit Use only the power cord supplied with the system The power cord should only be connected to a power outlet that has a protective ground contact Ensure that the power cord is easily accessible from the back of the system at all times Place the equipment in a well ventilated area where the vents are free from obstruction Do not place heavy objects directly on top of the RMX 2000 unit Do not use liquids around your equipment Rack Mount Safety Precautions The following precautions should be followed with regards to rack mount safety Keep the area around the RMX 2000 clean and free of clutter Decide on a suitable location for the equipment rack that will hold the RMX 2000 unit It should be situated in a clean dust free area that is well ventilated Avoid areas where heat electrical noise and electromagnetic fields are generated You will also need it placed near a grounded power outlet Ensure that the leveling jacks on the bottom of the rack are fully extended to the floor with the full weight of the rack resting on them 1 3 Chapter 1 Hardware Description In a single rack installation stabilizers should be attached to the rack In multiple rack installations the racks should be coupled together Always make sure the rack is stable before extending a component from the rack You should extend only one component at a time extending two or more simultaneously may cause the rack to b
6. the RMX unit is ON however a replacement drawer must be inserted immediately The temperature increase is detected by the system when critical a system shutdown is initiated Po LY Coys ee Slide in the replacement Fan Drawer Push the Fan Drawer firmly into the Backplane making sure it is properly seated in its slot Ensure that the metal ejector levers are fully retracted into their housings Tighten the captive screws on the front panel of the RMX 2000 that secure the Fan Drawer Polycom RMX 2000 Hardware Guide Replacing a RTM ISDN card 1 Ensure that power switch to the RMX 2000 is turned OFF O 2 Loosen the captive screws that fasten the card to the MCU 3 Remove the RTM ISDN board Use the metal ejector levers to pull the RTM ISDN Module out of its slot in the Backplane 4 Carefully slide the RTM ISDN Module out through the front panel 5 On the card to be installed move the ejector levers to their fully open position Ejector Lever Captive Screw 6 Slide in the replacement RTM ISDN Module 7 Insert the card into the slot until the ejector levers touch the front edge of the card cage 8 Push the ejector levers to their fully closed position 9 Tighten the captive screws on each side of the rear panel of the card securing the RTM ISDN card to RMX 10 Turn ON the RMX 2000 Chapter 1 Hardware Description 11 Connect the RJ 45 terminated PRI cables into any of the slots labeled PRII PRI1
7. when the MPM card Hot Swap functionality initiates a power off routine on the MPM and RTM ISDN boards ON Power on the RTM ISDN board has been switched OFF This Led is activated by the MPM board when the MPM s card Hot Swap functionality powers off the MPM and RTM ISDN boards Chapter 1 Hardware Description Component Replacement The RMX 2000 is designed with ease of maintenance in mind Most components are swappable and are accessible directly via the front panel or the rear panel The following components can be replaced when they are faulty e CPU CNTL Module e Multi Processor Module MPM Board s This board is Hotswap enabled e Power Supply Module e Fan Drawer e RTM IP Board Warning e All maintenance tasks are to be performed by qualified authorized personnel e Use only replacement parts supplied by your dealer e Follow all procedures Do not skip any steps Before replacing parts e To ensure a part needs replacing complete the troubleshooting procedures e Identify exactly which part needs replacing e Make sure you have the correct replacement part on hand e Make sure you are using proper ESD equipment to prevent damage to the system Hot Swappable MPM Boards All MPM Boards can be installed or removed while the RMX 2000 is powered on and operating The RTM IP and RTM ISDN Card are not Hotswappable System shutdown is required when replacing the ISDN or IP RTM card Polycom RMX
8. 2 RTMISDN 100 240 VAC 42A 50 60Hz ROn BREAKER PRI Cables LAN Up to 9 PRI cables can be connected to an RTM ISDN card with each card providing connection for up to 7 E1 or 9 T1 PRI lines When two RTM ISDN cards are installed up to a total of 18 PRI cables can be connected Polycom RMX 2000 Hardware Guide Replacing the RTM IP Board The RTM IP board on the rear of the RMX 2000 provides connectivity to all the MCU modules Use the following procedure to replace the RTM IP board 1 Ensure that power switch to the RMX 2000 is turned OFF O 2 Unscrew the captive screws on the rear panel of the RMX 2000 that secure the RTM IP board 3 Use the metal ejector levers to pull the RTM IP board out of its slot in the Backplane Carefully slide the RTM IP board out through the rear panel 5 On the card to be installed move the ejector levers to their fully open position 6 Slide in the replacement RTM IP board 7 Push the RTM IP board firmly into the Backplane making sure it is properly seated in its slots 8 Ensure that the metal ejector levers are fully retracted into their housings 9 Tighten the captive screws on the rear panel of the RMX 2000 that secure the RTM IP board 10 Turn ON the RMX 2000 Chapter 1 Hardware Description
9. 2000 Hardware Guide Prior to removing an MPM board the captive screws must be unscrewed and the ejector levers must be used to power down the card Powering down of the card by lightly pulling on the MPM card s ejector mechanism Once the ejector levers have been pulled a removal sequence is initiated and the process cannot be terminated When present the HS LED flash on the MPM and Control Unit When the HS led is constantly lit the card is powered down you can remove the card Power up is achieved when the card is re inserted and the ejector levers are pushed against the board s cage Installing an new MPM card in a powered On RMX2000 If applicable loosen the captive screws and remove the slot cover 2 On the card to be installed move the ejector levers to their full open position 3 Insert the card into the slot until the ejector levers touch the front edge of the card cage 4 Push the ejector levers to their fully closed position and tighten the captive screws on each side of the card securing the MPM RTM card to the RMX The blue HS LEDs on the MPM card and the Control Unit start flashing and the power on cycle for the card is initiated The card s resources are added to the system resources list The number of available ports on the RMX is increased to the current CFS license level Port usage is re calculated and the Port Gauges and Video Voice Port Configuration dialog box are updated When the powe
10. Layout 1 7 Chapter 1 Hardware Description The following items appear on the RMX 2000 rear panel Table 1 3 RMX 2000 Rear Panel RTM IP Component Description Ce ee NA Disconnected Note LAN 1 is covered with a plastic cap that should not be removed LAN 2 Used for the Network connection LAN 3 For Remote Access only using the Permanent Management Network For more information see the RMX 2000 Administrator s Guide Appendix F Alternate Management Network on page G 1 Note When not in use LAN 3 is covered with a plastic cap that should not be removed 10 100 ShMG NA For debugging purposes only Note 10 100 ShMG is covered with a plastic cap that should not be removed NA For debugging purposes only USB USB key connection For more information see the RMX 2000 Getting Started Guide First Time Installation and Configuration on page 2 1 Standby button Toggle between CPU activation and standby 1 8 Polycom RMX 2000 Hardware Guide RTM ISDN The RTM ISDN card connects directly to an MPM card The RTM ISDN card routes data between the MPM cards and components of the system converts ISDN T1 E1 media to IP packets and provides connectivity to external ISDN networks The RTM ISDN card is installed on the rear panel of the RMX interfaces between the RMX unit and the ISDN PSTN switch Up to two RTM ISDN cards can be installed in one RMX 2000 An RTM ISDN card must connect directly to an MPM
11. M card 10 Polycom RMX 2000 Hardware Guide Carefully slide the MPM Module out through the front panel POLE Eve uran N On the card to be installed move the ejector levers to their fully open position Slide in the replacement MPM Module Push the MPM Module firmly into the Backplane making sure it is properly seated in its slot Ensure that the metal ejector levers are fully retracted into their housings Tighten the captive screws on the front panel of the RMX that secure the MPM Module Chapter 1 Hardware Description Replacing the CPU CNTL Module The CPU module is the management system of the RMX 2000 Use the following procedure to replace a CPU CNTL Module 1 2 Ensure that power switch to the RMX 2000 is turned OFF O Unscrew the captive screws on the front panel of the RMX 2000 that secure the CPU CNTL Module Use the metal ejector levers to pull the CPU CNTL Module out of its slot in the Backplane Carefully slide the CPU CNTL Module out through the front panel On the CPU CNTL Module to be installed move the ejector lever to the fully open position Slide in the replacement CPU CNTL Module Push the CPU CNTL Module firmly into the Backplane making sure it is properly seated in its slot Ensure that the metal ejector levers are fully retracted into their housings Tighten the captive screws on the front panel of the RMX 2000 that secure the Functional CPU CNTL
12. TCA standard with a card manager CM and up to 26 720Mhz TI DSP s Two types are available e MPM F 26 DSP s e MPM H 13 DSP s 1 6 Polycom RMX 2000 Hardware Guide RMX 2000 Rear Panel The RMX 2000 rear panel contains the RTM IP board and optionally the RTM ISDN board In addition the rear panel houses the main power switch AC inlet a circuit breaker and additional communications ports RTM IP The RTM IP board provides system shelf management based on the ATCA standard and connects to the backplane It controls and monitors fans on the system and regulates power supply This board contains an Ethernet Switch managing the network of the system and routing traffic This board routes data between the boards and components of the system and provides connectivity to external IP networks Connections include e 3LAN ports e 10 100Mb ShMG port Future Use e 1 Serial port Future Use e 1USB port LAN1 LAN3 and the 10 100Mb ShMG ports shall not be used and the plastic caps covering those ports should not be removed LAN 1 3 Ports 10 100Mb ShMG Internal LAN Serial USB Standby button amp amp LEDs LAN amp LEDs connections Port Port LED LNK 1GbLNK 1Gb LNK 1Gb STAND a at SERIAL BY 10 100 5 ShMG 1Gb L I A LNK LNK LNK ERR act 1Gb 1Gb 1Gb RDY HS 2 3 SLOT LAN1 LAN 3 ShMG and the Serial ports are only for debugging and not for customer use Figure 1 2 RMX 2000 RTM IP Rear Panel
13. X 2000 Rear Panel LEDs RTM IP The following items appear on the RTM IP board Table 1 5 RMX 2000 RTM IP LEDs Name LAN LEDs 1 3 LNK Green Lit with active network connection flickers with Packet activity 1 Gb Amber Lit when 1Gb connection online flickers with Packet activity Chapter 1 Hardware Description Table 1 5 RMX 2000 RTM IP LEDs Continued Name LNK Green Lit with active network connection flickers with Packet activity 100 Amber Lit when active network is 10 100Mb flickers with Packet activity LNK 1 4 Green Lit with active network connection flickers with Packet activity 1Gb 1 4 Amber Lit when 1Gb connection online flickers with Packet activity ERR 10 100 ShMG LEDs SLOT 1 4 LEDs ShMG LEDs Standby LED 1 14 Red ON Major error on RTM board ON Packet flow to and from the MCU chassis ON RTM IP board has successfully completed startup OFF Normal Flashes During power down process ON RTM IP board may be removed ie CPU amp System are ina cae OFF mode Polycom RMX 2000 Hardware Guide RTM ISDN The following items appear on the RTM ISDN rear panel Table 1 6 RMX 2000 RTM ISDN Rear Panel LEDs Name LAN LED 1 LNK Green Lit with active network connection flickers with Packet activity Amber Lit when 1Gb connection online flickers with Packet activity ShMC LEDs Blue OFF Normal Normal C This Led is activated
14. ar Panel on page 1 7 RMX 2000 Front Panel Figure 1 1 shows the front panel of the RMX 2000 The front panel provides access to the RMX 2000 main CNTL modules MPM modules Power Supply drawer Status LEDs and Fans Fan drawer amp Power MPM Boards amp LEDs LED POLYCOM RMX 2000 Power supply drawer USB ports are only Control Unit amp LEDs 2nd CPU amp LEDs for debugging and not for customer use Figure 1 1 RMX 2000 Front Panel 1 5 Chapter 1 Hardware Description Table 1 2 Polycom RMX 2000 Component Description CPU CNTL The CPU Module controls and manages the RMX 2000 Module The CPU Module has an ComExpress Pentium M 1 4 GHz processor a 40GB hard disk drive 1GB Compact Flash and 512MB of DDR RAM The Operating System is Linux Power Supply The Power Supply Module is housed in a drawer and Drawer located below the MPM Modules The Power Supply drawer is connected to the backplane by means of a power connector Operates at 100 240 volts AC 50 60 Hz and provides 48VDC 700W output with built in load sharing capabilities Fan Drawer Three fans are mounted sideways in the right front panel Three fans are mounted in the drawer Airflow is from right to left and out the side of the MCU The drawer is connected to the back plane by a connector Multi Processor The MPM Boards perform the various RTP audio and Module MPM video processing functions on the RMX 2000 unit Board Boards are based on the A
15. ceessescesesseseesteseeseeeesseeseeeees 1 10 E E A TTT 1 10 Cables Connected to the RTM IP amp ISDN Boards 1 11 RMX 2000 LEDS nsii E EERE AiR 1 12 RMX 2000 Front Panel LEDS oo eee ceeeseeeeeececneeeeseraesenes 1 12 RMX 2000 Rear Panel LEDS oo eee ceeseeeseeeeeneeeeseeaesenes 1 13 RIM IP protini hanes EE E aes 1 13 RIM ISDN pererin terae creat cen a e RE 1 15 Component Replacement ceecseceseecesseeeeceeerseseseetecneeeesenaesenes 1 16 Hot Swappable MPM Boards oo eesetsseseseresseeeeceneeesenaesenes 1 16 Installing an new MPM card ina powered On RMX2000 1 17 Replacing a powered On hot MPM card ues 1 18 Replacing the CPU CNTL Module oo eee eee 1 20 Replacing the Power Supply Drawer uu ec cceeeeeseeeeeees 1 21 Replacing the Fan Drawer 0 cc cece ee teeeeeee este teneneeeee tenes 1 22 Replacing a RTM ISDN card 0 cence ce ceeeeecseeeeaeees 1 23 Replacing the RTM IP Board ou eee eeeseeee este ceneeeeene tenes 1 25 Table of Contents Hardware Description This Hardware Guide provides information on the RMX 2000 and its components This system utilizes a modular universal slot platform whose components are designed for high performance capacity and reliance e Main Features The Polycom RMX 2000 offers the following features Linux based Chassis based on the ATCA standard Support for standard network interfaces IP ISDN and LAN and large number of ports H 323 SIP video amp
16. connections of the power utility telephone lines and internal metallic water pipe system if present are connected together This precaution may be particularly important in rural areas Caution Users should not attempt to make such connections themselves but should contact the appropriate electric inspection authority or electrician as appropriate Regulatory Notices Chinese Communication Certificate mA JEN A Barat AARE PT ATAE AIT ARB OLR AER 2A RE TAKRIRI T Singapore Certificate RMX 2000 complies with IDA standards G0916 07 Polycom RMX 2000 Hardware Guide Table of Contents Hardware Description ccccccececccceee l 1 Main Features seinna n Eei asean E Eaa an E ENEE AAE ESS 1 1 RMX 2000 Specifications s sssssesessseesesetsesetssrerisertrserrseerrsrsrrnesrrsessrsess 1 2 Dite Require mems scorre n E E R 1 3 Safety Requirements si c iciccccsessesenessesessssetotecdesvessneentonssehesstenvedeenes 1 3 Rack Mount Safety Precautions 0 0 0 0 ccs eeeeseeeeeeereeeeees 1 3 Installation Precautions 0 0 ccseseeeseseeeeecseeeeeseseecnseeeecseaeeeeeeeeas 1 4 RMX 2000 Compone mts c sc satsscazevsesssceseiseasilessiseacstesessenseseseensssnaseeesseneasy 1 5 RMX 2000 Front Panel occ eesseseecseseeeeecseseeeseeseecaeeeeesseateceetenas 1 5 RMX 2000 Rear Panel ccseeeeeceeseeessesescnseeecseaeeeseeaeas 1 7 RIM IP renin aana E 1 7 RTM ISDN ern ereenn ninin e a E EEES 1 9 ISDN PSTN Clock Source ccce
17. ecome unstable Before you install the rails determine the placement of each component in the rack Install the heaviest components on the bottom of the rack first and then work up Allow the power supply units to cool before touching them Always keep the rack s trays and board s closed when not servicing to maintain proper cooling Installation Precautions 1 4 C When handling electronic components standard anti static precautions must be observed Wear a grounding strap Handle cards by their edges only and do not touch their components or connector pins Keep components in anti static bags when not installed in the RMX2000 The following precautions should be followed with regards to installation of the RMX 2000 Use a regulating uninterruptable power supply UPS to protect the RMX 2000 from power surges and voltage spikes to keep your MCU operating in case of a power failure Place the RMX 2000 on a hard flat surface such as a desktop or mount it on 19 rack The airflow of the RMX 2000 is from right to left Be sure that the areas in the left and right side of the system are clear for proper ventilation Polycom RMX 2000 Hardware Guide RMX 2000 Components On the RMX 2000 modules are located on both the front and rear of the MCU as listed in Table 1 2 Polycom RMX 2000 Component Description For more information see the descriptions of the RMX 2000 Front Panel on page 1 5 and RMX 2000 Re
18. nterference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manuals may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his or her own expense Part 68 Network Registration Number This equipment is registered with the FCC in accordance with Part 68 of the FCC Rules This equipment is identified by the FCC registration number If requested the FCC registration Number and REN must be provided to the telephone company Any repairs to this equipment must be carried out by Polycom Inc or our designated agent This stipulation is required by the FCC and applies during and after the warranty period United States Safety Construction Details All connections are indoor only Unit is intended for RESTRICTED ACCESS LOCATION Unit is to be installed in accordance with the National Electrical Code The branch circuit overcurrent protection shall be rated 20 A for the AC system This equipment has a maximum operating ambient of 40 C the ambient temperature in the rack shall not exceed this temperature To eliminate the risk of battery explosion the battery should not be replaced by an incorrect type Dispose of used batterie
19. r on cycle of the MPM card is completed the blue HS LEDs will turn OFF The green RDY LED on the MPM card switches on and remains lit Chapter 1 Hardware Description Replacing a powered On hot MPM card Loosen the captive screws that fasten the card to the MCU Pull the ejector levers on the sides of the card forward and slightly outward until the blue HS LED on the card and the Control Unit start to flash Once the removal sequence is initiated the process cannot be terminated and eS Warning the HS led flashes if activated 3 The power off sequence for the MPM and RTM ISDN boards are initiated as follows All participants connections on the card are disconnected A fault is generated on the system For each disconnected participant a participant disconnection event is written to the CDR with the disconnection cause Disconnected by Operator New participant connections are blocked when the card is removed If an RTM ISDN card is connected to the MPM card it is also powered off and all PSTN participants are disconnected When an RTM ISDN card is removed its resources are deducted from the Resource Report A Log File entry is written indicating MPM card removal Port usage is re calculated and the Port Gauges and Video Voice Port Configuration dialog box are updated When the blue HS LEDs on the MPM RTM and Control Unit stop flashing and remain lit move the ejector levers to their fully open position and remove the MP
20. s according to their instructions CE Mark R amp TTE Directive Polycom Inc declares that the Polycom RMX 2000 is in conformity with the following relevant harmonized standards EN 60950 1 2001 EN 55022 1998 A1 2000 A2 2003 class A EN 300 386 V1 3 3 2005 Following the provisions of the Council Directive 1999 CE on radio and telecommunication terminal equipment and the recognition of its conformity Canadian Department of Communications This Class A digital apparatus complies with Canadian ICES 003 Notice The Industry Canada label identifies certified equipment This certification means that the equipment meets telecommunication network protective operational and safety requirements as prescribed in the appropriate Terminal Equipment Technical Requirements document s The Department does not guarantee the equipment will operate to the user s satisfaction Before installing this equipment users should ensure that it is permissible to be connected to the facilities of the local telecommunications company The equipment must also be installed using an acceptable method of connection The customer should be aware that compliance with the above conditions may not prevent degradation of service in some situations Repairs to certified equipment malfunctions may give the telecommunications company causes to request the user to disconnect the equipment Users should ensure for their own protection that the electrical ground
21. the protective caps from LAN1 LAN3 and ShMG ports 1 11 Chapter 1 Hardware Description RMX 2000 LEDs The RMX includes LEDs located on the front panel and rear panel In the front panel the LEDs reflect the state of the module The LEDs on the rear panel indicate the state of the external connections and the status of the RTM IP board RMX 2000 Front Panel LEDs The following items appear on the RMX 2000 front panel Table 1 4 RMX 2000 Front Panel LED s Fan Status Green a Warning Fan failure Error Problem with power supply ERR Red ON Major system error RDY Green ON CPU board has successfully completed startup Amber ON At least one endpoint is connected to the system OFF Normal Normal o Hard disk is active Flashes Indicates when the power down process is initiated on an MPM board This Led flashes in synchronization with the MPM s boards HS Led ON CPU may be removed 1 12 Polycom RMX 2000 Hardware Guide Table 1 4 RMX 2000 Front Panel LED s Continued SS ON Major error on board Green ON The board has completed startup successfully ACT Amber ON At least one participant is connected to a conference HS Blue Flashes Shut down process initiated by lightly pulling the CPU ejector levers This Led flashes in synchronization with the CNTL s board s HS Led ON The card can be removed safely once the CPU ejector levers are fully open RM