1. Warnings 8 m 26 25 feet XLR XLR cable Programming cable Owner s manual RP 1 RoomPerfect LYNGDORF This manual Microphone stand with Mic clamp delivered in a separate carton LYNGDORF Front Panel LYNGDORF RP 1 Room Processor Room Perfect Controls The buttons controls on the front panel of the RP 1 can all be operated with a direct press 1 Mains Switch Powers the RP 1 on off 2 Display Display with all information on menu system and status 3 Navigation Keys Pressing the Enter button for 3 seconds will set the RP 1 in stand by mode and turns On the RP 1 from stand by mode with a short press In normal operation mode the Up Down toggles between the Focus and Global filter and Bypass where as the Left Right toggles between neutral and the available voicings In menu mode used for navigation in the menu system Up Down Left Right amp Enter Pressing and hold ing down the Up Down Right Left keys changes some selected values fast 4 Menu Button Toggles Menu mode on off and navigates one level back when in menu mode LYNGDORF Display Indicators 1 Menu Alphanumeric Display 2 20 Characters 2 Standby Indicator Power On is indicated with display showing all information on status
2. Connect and place mic in focus pos appears connect the microphone to the mi crophone input found on the back panel Thereafter place the microphone using the microphone stand in an appropriate focus listening position This location should be at your main listening position typically more or less centered between the loudspeakers Make sure that the height and the orientation of the microphone corresponds to your typical listening height and direction as illustrated and do not block the line of sight between the microphone and the loudspeakers When the microphone has been correctly connected and placed in the focus position you are ready to set the calibration volume The calibration signal is a combination of the high and low frequency measur ing signals and is only presented in your left loudspeaker The measuring signals sound very artificial and disharmonic due to the fact that they are composed of pure tones at different frequencies Press Enter to confirm and to commence the calibration process If the RP 1 is connected before the volume control of your amplifier e g when using Option 2 or a tape 2 loop as described in Option 3 in the Connecting the RP 1 chapter be aware that the volume control of your amplifier is set at an appropriate level when making the RoomPerfect calibration The volume control should be set at OdB which typically is in the 12 o clock po sition This setting must be used ag
3. Standby mode is indicated with the Standby Indicator being lit only 3 RoomPerfect Logo Is illuminated whena RoomPerfect filter is engaged Rear Panel C J Q gt C gt z Q CX is EA CL C C gt 100 120V 220 240V NOS INPUTS MAIN LINE OUTPUTS ples ow 1 Analog Output Double pairs of balanced XLR Left Right analog outputs Main and Line out The best performance is obtained by using the balanced output Also it is possible to mix balanced and unbalanced connections i e to connect e g the main channel via the balanced output and the line chan nel via the unbalanced output Never connect balanced and unbalanced Line or Main out at the same time Only connect either balanced or unbalanced for each Main out Line out 2 115V and 230V mains voltage switch Switches between 115V and 230V mains input voltage Make sure the rear selector is in the correct setting and connect the power input only to an appropiate AC source The warranty will not cover any damage caused by connecting to a wrong type of AC mains LYNGDORF 3 Analog Input Balanced XLR Left Right Analog input Never connect balanced and unbalanced Input at the same time 4 Analog Input Unbalanced RCA Left Right Analog input The default Input setting is Balanced XLR This can be changed to Unbalanced RCA from
4. Left Right buttons on the re mote or front panel The can also be selected directly by pressing info followed by the voicing number on the remote control 17 LYNGDORF RoomPerfect The sub menus accessible in the RoomPerfect menu are Guided setup Advanced options Advanced options is only available when Guided set up has been performed Guided Setup When you enter the RoomPerfect Main Menu for the first time only the Guided setup is available Press Enter to initiate the guided set up The main steps in the guided set up procedure are Setting the measurement volume level Taking one Focus listening position measurement Taking at least three room position measurements Finally automatic calculation of Focus and Global filters If you wish to leave the guided set up at any time during the set up simply press the Menu button and the following message appears Exit without saving No Yes Choose Yes to exit the guided set up without saving any data or Choose No to cancel and continue with the guided set up LYNGDORF Setting the Measurement Volume Level When setting the measurement volume level it is important that you always judge whether the calibra tion volume is too loud The calibration volume should not be so loud that it causes e uncomfortably loud sounds that are inconvenient to you or your environment or e damage to your loudspeakers When the message
5. and Bypass you simply press the Up Down buttons on the front panel or remote control They can also be selected directly with the numerical buttons on the remote O for bypass 1 for Focus or 9 for Global Global Listening The Global filter improves the sound quality across the whole room When you are listening to music in a room but are not sat in any particular listening position the global filter gives the best result Focus Listening The Focus filter improves the sound quality at a listening position by exploiting the 3 dimensional acous tic properties gained through the room measurements This makes the Focus filter the best solution for optimal sound quality at a specific listening position Voicing When using RoomPerfect you will experience a much more precise and detailed sound reproduction which could also be described as more analytical The Voicing setting is an EQ filter that can be used to gently amplify or attenuate certain frequencies ac cording to your personal preferences and or to compensate if a given recording sounds too bright or too dark The standard voicing settings and their numerical value on the remote control are e Neutral 0 Music 1 1 Music 2 2 Relaxed 3 Open 4 Open Air 5 Soft 6 The frequency curves of the different voicing settings can be viewed in the appendix Neutral is a bypass setting You can toggle between neutral and the available voicings by pressing the
6. and current status of the RP 1 An overview of the menu tree can be seen in the Menu Tree chapter Navigating the Menu System Pressing the Menu button on the front panel or the remote enters the menu or steps back one level in the menu system Use the left right arrows keys to navigate the Menu system To access a sub menu setting press the Enter button To change a setting use the Up Down and or Left Right arrows and press Enter to accept the change or Menu to exit without applying any changes Pressing and holding down the Up Down Right Left keys changes some selected values fast 15 LYNGDORF Menu Tree This is an overview of the entire RP 1 menu structure RP 1 Main Menu RoomPerfect Advanced setup Guided setup Communication Advanced options Comm Address Change Focus Pos Comm Speed Measure Room Pos Line Out Level Crossover freq RoomKnowledge RoomCorrection Displa E Filter Type Display Timeout Disp Brightness Remote Control Input Connection Firmware Versions Factory Reset Input Sensitivity LYNGDORF Introduction to RoomPerfect Once the guided set up has been successfully completed you have the option to listen to music through two listening settings Focus and Global room correction filters To toggle between the two filters
7. must be calibrated as described in the Guided Setup chapter Then place the micro phone in a random room position and the measurement can commence The volume can be changed at any time between measurements to suit a particular measurement situ ation After a successful room measurement the RoomKnowledge is re calculated and displayed as Room Knowledge XX Measurement X ok Press Enter to continue 23 24 LYNGDORF Add more room meas Yes No will show in the display e choose Yes to add another room measurement or e choose No to stop adding more room measurements If No is chosen the RP 1 is will return to full scale output Save room measurement s Yes No will hereafter be shown e choose Yes to save the performed room measurement e and No to exit without saving any of the performed measurements Adding one or more room measurements leads to a re calculation of both filters i e Global and Focus filters due to the fact that more of room s acoustic properties have been learned something that affects these filters When adding room measurements make sure the system volume is the same for all measurements Whether adding more room measurements now or later If you can t remember the volume setting we recommend to delete the filter and start over RoomKnowledge The RoomKnowledge index is a parameter that tells how much of the room s acoustical properties have been learned A high RoomKno
8. preamplifier and connect it to the RP 1 input Then connect the RP 1 output signal to a poweramplifier E ee n ae E E i J E Source s o A Poweramp 2 Connect a single audio source to the RP 1 input Then connect the RP 1 output signal to your integrated or preamplifier uu WI o e Integrated amplifier Preamp 3 LYNGDORF If your integrated amplifier or preamp has a tape 2 loop sometimes called recording loop or Pre in out Connect the output of the tape 2 loop Pre out to the input of the RP 1 Then connect the output of the RP 1 to the input of the tape 2 loop Pre in Using this configuration enables you to use multiple audio sources without switching source and or cables since the tape 2 loop Pre in out is always active and not depending on other used inputs and outputs Integrated amp Preamp poweramp Al When using Option 2 or a tape 2 loop as described in Option 3 be aware that your amplifiers volume control is set at an appropriate level when making the RoomPer fect calibration Please refer to the chapter Setting the Measurement Volume Level for further information 13 LYNGDORF Setup options of Main and Line outputs As described in Routing and Crossover Frequency there are many ways to utilize the Main and Line out puts Here we have described the three most common set up s Ple
9. that results in prolonged measuring times Solution e Raise the RP 1 s measuring volume or the volume setting of your amplifier before continuing with the measurement or reduce the noisy elements in your environment Signal clipping 1 The error message Fault Signal clipping is displayed when the incoming signal is classified as too loud resulting in clipping distortion 2 Aloud noise from the local environment that has corrupted the measurement results in this error message Solution e Lower the measuring signal volume before continuing with the measurement e Repeat the measurement with no changes however refrain from making excessive noise when measuring 31 32 LYNGDORF Troubleshooting RP 1 Speakers are humming when the RP 1 is turned on Balanced and unbalanced for Main out connections are used at the same time Solution e Disconnect the interfering connection Speakers are humming when the RP 1 is turned on Balanced and unbalanced for Line out connections are used at the same time Solution e Disconnect the interfering connection Speakers are humming when the RP 1 is turned on Balanced and unbalanced for Input connections are used at the same time Solution e Disconnect the interfering connection and remember select the correct setting in the input connection menu LYNGDORF Firmware Upgrading The RP 1 firmware can be upgraded using the Lyngdorf Audio Serial
10. the Input Connection menu If the setting is not set correctly you may experience humming 5 Analog Output Double pairs of unbalanced RCA Left Right analog outputs Main and Line out Never connect balanced and unbalanced Output at the same time 6 Mic In Mic in for connection of RoomPerfect microphone 7 RS232 Input Aux RS232 communication connectors for communication with a PC for firmware update remote control from other Lyngdorf equipment with broadcast commands or linked control between several other ampli fiers or other suitable equipment with a remote start e The INPUT is used for connection to a PC or as a control input from a Lyngdorf master amplifier e The AUX connection bypasses input from other master amplifiers to the next amplifier 8 Mains Input LYNGDORF Remote Control The remote control is used to access the menu system as well as the buttons directly accessible on the front panel To control the RP 1 the RCS Room Correction System key must be pressed The functionality of the buttons when RCS is pressed are as follows 1 Standby The standby button puts the RP 1 in stand by mode 2 Numerical Button 1 Select focus listening mode 3 Numerical Buttons 2 8 No function 4 Numerical Button 9 Selects global listening mode 5 Digital No function 6 Numerical Button O Selects bypass listening mode no room correction filter selected 7 Info To select a specif
11. used to check the current firmware version of your RP 1 and the Room Perfect module as well as the RoomPerfect serial number Factory Reset Factory Reset The Factory Reset setting is used to restore all settings including RoomPerfect in the RP 1 to the fac tory settings If you return to the factory settings all your personal settings will be erased LYNGDORF Troubleshooting RoomPerfect No microphone connected The error message No microphone connected is displayed when no microphone is connected to the RP 1 Solution 1 The error message Fault No signal is displayed when the incoming signal is classified as pure noise This happens when the RP 1 s measuring signal is too low compared with the noise from the local environment 2 The volume setting of your amplifier and or RP 1 measuring volume is to low 3 The above error message is also displayed when the loudspeakers are not connected Solution e Reduce the noise in your measuring environment e Raise the volume setting of your amplifier and or RP 1 measuring volume before continuing with the measurement e Connect your loudspeakers The error message Fault Low signal is displayed when the measurement has taken more than 5 minutes for the low frequency signal or 2 minutes for the high frequency signal This happens when the system calibration volume is low compared to the background noise of your environment some thing
12. 10 cm This will increase the bandwidth of the subwoofer However due to the limited bandwidth frequency response of most conventional subwoofers you might find it necessary to choose a lower crossover frequency When building active speaker systems it is recommended to use the original crossover point s used by the manufacturer Due to the short wavelengths of the mid high frequencies it is essential that both crossover frequency filter tyoe and order as well as delay is set correctly Therefore creating filters for active speakers is an iterative process that requires several critical listening sessions in order to achieve seamless integration of the different speaker drivers Filter Type Filter Type Filter Type is only available when Routing has been setup It is possible to choose from two different Filter Types in this menu LIRI Linkwitz Riley 2 4 or 8 order Butw Butterworth 1 2 or 4 order In a 2 2 set up main speakers Lyngdorf Audio boundary woofers we recommend using a fourth order Linkwitz Riley filter In set ups using conventional active subwoofers again due to limited bandwidth we recommend us ing a second order butterworth filter In active speaker systems it is recommended starting with a fourth order Linkwitz Riley filter LYNGDORF Delay If you are using a set up with two main loudspeakers located at an identical distance to the listening position you don t need to set a d
13. Comm Address Comm Speed Comm Address The Communication Address setting identifies the RP 1 to the PC interface or other Lyngdorf products In master mode the Lyngdorf equipment is normally set for 1 and the addresses 2 99 can be used for pre amplifiers etc but nothing is restricted Comm Speed The Communication Speed setting is the RS232 Link interface speed The default setting is 57600 baud With different PC s and different lengths of cables the settings can be changed to 9600 or 115200 baud If a multi amplifier set up is installed with Master Slave communication a faster response can be ob served when using higher speeds LYNGDORF Line Out Level Line Out Level This adjusts the overall output level in steps of 0 1 db it can be attenuated to 40 dB in total Routing Routing In Routing it is possible to apply different settings to the Main and Line outputs 08 CCT AAA A highpass and a lowpass filter can be applied to the Main and Line outputs when you want to connect an additional amplifier or subwoofer along with your main amplifier A Mono setting is also available for the Line output this is used when connecting a single subwoofer to the Line output If no filter is selected the full frequency range will be directed to the Main and Line Out terminals If a filter is selected the frequencies above or below the selected crossover frequency will be directed to the analog Main or Li
14. Load software This is in the PC package available from www Lyngdorf com Press the Enter button while powering On to bring the product into upgrade mode Lyngdorf Audio Serial Load D AP 1 releases RP1_01 s19 I Upload File for RP 1 and file is ok 33 34 LYNGDORF Connectors Mains Connector Mains voltage to the RP 1 is applied via an IEC320 type connector The supplied cable with safety ground should be used to connect the RP 1 to a mains outlet Make sure the rear selector is in the correct setting and connect the power input only to an appropiate AC source The warranty will not cover any damage caused by connecting to the wrong type of AC mains Always disconnect the RP 1 from the mains before changing any connections to its inputs or outputs Balanced Inputs The balanced XLR inputs are wired in accordance with IEC268 Pin 1 Chassis and ground Pin 2 Hot Pin 3 Cold Shell Chassis and ground Unbalanced Inputs The unbalanced RCA inputs are wired in accordance with normal practice Shell Chassis and ground Pin Hot Cleaning and Maintenance This unit does not require any regular maintenance except to keep its exterior clean Simply wipe its exte rior with a clean soft cloth A small amount of non abrasive cleaner may be used on the cloth to remove any excessive dirt or fingerprints Do not use abrasive cleaners or cleaners containing liquid solvents LYNGDORF Techn
15. Owners manual RP 1 RoomPertect LYNGIDORF LYNGDORF LYNGDORF Table of Contents Operating Voltage Unpacking the RP 1 Serial Number Registration Introduction Accessories Front Panel Display Indicators Rear Panel Remote Control Connecting the RP 1 Connecting to sources and amplifiers Setup options of Main and Line outputs Menu System Navigating the Menu System Menu Tree Introduction to RoomPerfect Global Listening Focus Listening Voicing RoomPerfect Guided Setup Setting the Measurement Volume Level Focus Measurement Room Measurements Adding more Room Measurements Calculation of Focus and Global Filters Advanced Options Change Focus Pos Measure Room Pos RoomKnowledge RoomCorrection Display Display Timeout Display Brightness 12 12 14 15 15 17 17 17 17 18 18 19 20 20 21 22 23 23 23 24 24 25 25 25 Input Connection Input Sensitivity Advanced Setup Communication Comm Address Comm Speed Line Out Level Routing Crossover Frequency Filter Type Delay Remote Control Firmware Versions Factory Reset Troubleshooting RoomPerfect RP 1 Firmware Upgrading Connectors Mains Connector Balanced Inputs Unbalanced Inputs Cleaning and Maintenance Technical Specifications Audio Protection Mains Mechanical Technic
16. age could occur and void the warranty Serial Number Registration Please record the serial number of your RP 1 here for future reference The serial number is printed on the label on the rear panel You will need this serial number should you ever require service for your RP 1 RP 1 serial number LYNGDORF Introduction Congratulations on the purchase of your Lyngdorf Audio RP 1 with RoomPerfect This Black Box expands your existing music system with the most advanced room correction system on the market It is implemented in such a way that you will always achieve the perfect result No com puter needed no acoustic knowledge needed no user input needed We leave nothing to chance in the fully automated calibration process However for the advanced user there are plenty of challenges since the RP 1 is also a complete Control Centre that allows you to build advanced multi way passive or active speaker systems This is possible due to the very powerful built in DSP engine which facilitates signal routing creation of active cross overs delay settings etc In fact we believe the RP 1 to be a true Black Box in the way that it sets new standards for what s pos sible to improve sonically in a music system LYNGDORF Accessories You should find the following accessories included Microphone 00000 20 D000 8 0000 00 00 e0
17. ain if you wish to add additional RoomPerfect measurements later The test signal will start and shortly thereafter the RP 1 will suggest an initial estimate of the desired maximum calibration volume displayed as Adjust level XX up down Retry Save Current Please raise or lower the volume by pressing the Up Down buttons on the RP 1 front panel or remote control towards the desired number of steps shown on the display but ensure you avoid clipping uncom fortably loud levels and damage to the loudspeakers Continue choosing Retry for a re estimation of the desired maximum calibration volume until an appropriate calibration volume is reached If you find the suggested calibration volume too loud simply turn down the volume to an appropriate level and choose Save current 19 20 LYNGDORF When the message Calibration ok Press Enter to continue is displayed the calibration volume has suc cessfully been set and saved Focus Measurement When the calibration is OK press Enter to start the measuring process and Measuring Focus position will be displayed Each measurement comprises four steps e Alow anda high frequency measuring signal first in the left and then in the right channel The length of each measurement depends on a combination of the measurement volume set in the calibration process and the background noise in your local environment Typical measuring times for the low and high frequency measuring
18. al Assistance Appendix Voicing Curves Manual version 02 05 08 25 26 26 26 26 26 27 27 28 28 29 29 30 30 31 31 32 33 34 34 34 34 34 35 35 35 35 35 36 37 37 LYNGDORF Operating Voltage The RP 1 can be switched between 115V and 230V mains voltage In 115V mode the RP 1 requires a mains voltage of 100V 120V at 50 60Hz In 230V mode the RP 1 requires a mains voltage of 220V 240V at 50 60Hz The mains voltage setting for your RP 1 can be changed on the rear selector Make sure the rear selector is in the correct position and connect the power input only to the appropiate AC source The warranty will not cover any damage caused by connecting to the wrong type of AC mains The RP 1 has three power modes 1 OFF No circuitry is powered Please note that some parts of the mains entry section still carry live mains 2 STANDBY The microprocessor is active 3 ON All circuits active Unpacking the RP 1 Carefully remove the unit and accessory kit from the carton visually check for shipping damage Contact both the shipper and your Lyngdorf Audio representative immediately if the unit bears any sign of damage from mishandeling All Lyngdorf Audio equipment is carefully inspected before leaving our factory Keep shipping carton and packing material for future use or in the unlikely event that the unit needs servicing If this unit is shipped without the original packaging dam
19. an be set to e Balanced XLR or e Unbalanced RCA The default setting is Balanced XLR Remember to select the same input as physically connected If the setting is not correct you may experience humming 25 26 LYNGDORF Input Sensitivity Input Sensitivity The Input Sensitivity setting enables you to match the line level output of your pre amplifier to the input sensitivity of the Lyngdorf Audio RP 1 The normal settings are e Select High for input levels lt 2 2Vrms and the output input levels of your pre and power amplifier will match e Select Low for input levels gt 2 2V RMS e Select High Gain for input levels lt 2 2Vrms and add an extra 6dB gain to increase the output level of your pre amplifier to match your power amplifier This setting is only to be used in special cases where the output level from your pre amplifier is too low to obtain full output from your power amplifier In High and Low sensitivity the RP 1 has unity OdB gain Selecting the correct setting will prevent clipping distortion and obtain full scale out put from your pre amplifier Advanced Setup The sub menus accessible in the Advanced menu are Advanced setup Crossover freq Remote Control Communication The sub menus accessible in the Communication menu are Filter Type Firmware versions Delay Factory Reset di il Communication
20. ase note the products outputs and cross over frequencies are chosen randomly in these descriptions Combine them as you see fit 1 Single amp set up with full range main speakers no subwoofer A poweramp is connected to Main Outputs Left and Right No crossover is selected Main Output Left RP 1 Main Output Right No filter y f No filter o NE AL Speaker o Poweramp Speaker 2 Poweramplifier and subwoofer set up A poweramp is connected to the Main Outputs Left and Right and the highpass crossover is set at 80Hz The Subwoofer is connected to the Line Output and the lowpass crossover is set at 80Hz Remember to bypass or set the subwoofer cut off frequency to maximum Main Output Left Right RP 1 Line Output Right Highpass filter set at 80Hz t j Mono lowpass filter set at 80Hz a eS 2 ca o Poweramp Active subwoofer Speakers 3 Lyngdorf 2 2 setup A poweramp is connected to Line Outputs Left and Right and the highpass crossover is set at 400Hz Lyngdorf boundary woofers are connected to Main Outputs Left and Right through a poweramp and Line Output Left Right RP 1 Main Output Left Right the lowpass crossover set at 400Hz Highpass filter set at 400Hz f f f f Lowpass filter set at 400Hz j AA TI TE p a gt E 2 l z gt es Oz Poweramp o Poweramp i Boundary woofers Speakers 14 LYNGDORF Menu System The Main Display on the front panel of the RP 1 shows all functionality
21. e varying positions heights and orientations of the microphone LYNGDORF For an optimal room correction it is very important that the measurements are 1 performed more than 1 meter approx 3 feet away from the loudspeakers 2 not performed behind the loudspeaker and 3 that there is at least 50 cm 1 5 ft between each measurement Y s 3 2 e E O When a random measuring position and microphone orientation has been chosen press Enter The measur ing process will start and the display will show Measuring room position 1 The measurement will stop prematurely if an error occurs during the measuring process In this case the error message Retry room measurement press Enter is displayed Press Enter to continue If it is an error that needs correcting then correct the error see RoomPerfect trouble shooting and pro ceed with the room position measurement by pressing Enter The measurement has ended successfully when the last measuring signal stops and the display shows RoomKnowledge XX Measurement ok This process is repeated at least three times and until the RoomKnowledge reaches 90 Adding more Room Measurements If you have performed successful measurements and RoomKnowledge has reached 90 the message Add more room meas Yes No is displayed At this point or any time later you can decide whether the acquired room measurements are sufficient or you wis
22. elay However if the distance isn t identical and or you are using a sub woofer or a Lyngdorf Audio 2 2 system you need to set a delay in order to ensure that the sound from each loudspeaker reaches the listening position simultaneously This must be done for main left ML and right MR and as well as line left LL and right LR To set the delay all you need do is to measure the distance from each loudspeaker to the listening posi tion and enter these values in the menu The necessary delays are then automatically calculated and applied to each channel 1 centimeter 0 3937 in The fault message Values for delay exceed limits is displayed when the difference between the distance from the speakers closest to and the speakers furthest from the listening position is too big The biggest difference allowed is 340 cm 134 in If the fault message appears you can use the following solutions Can be used individually or together to achieve a valid set up with respect to the delay lengths e Shorten the distances between your Main and Line channel loudspeakers resulting in a more compact loudspeaker set up e Arrange your loudspeaker set up and or your listening position in a more symmetrical set up Remote Control Remote Control set up makes it possible to activate or de activate the remote control Remote Control 29 30 LYNGDORF Firmware Versions Firmware versions The Firmware Versions menu is
23. h to add further room measurements to learn more about the room s acoustical information Adding more room measurements results in a higher RoomKnowledge this in turn improves the room correction filters e Choose Yes to add more room measurements The room measuring process is now continued as described in the previous section e Choose No when no additional measurements are required The RP 1 will return to full scale output The message Save guided measurement Yes No will be displayed when exiting a successfully completed guided set up e Choose Yes to save the results of the guided set up and calculate the focus and the global room correction filters e Choose No if you wish to exit the guided set up without calculating any room correction filters without saving the performed measurement 21 22 LYNGDORF Calculation of Focus and Global Filters When RoomPerfect calculates the filters the display shows the following Calculating filters Please wait The filter calculation process can be expected to take anywhere between 5 seconds and a minute de pending on the specific task When RoomPerfect has calculated the room correction filters they are automatically saved You have now successfully completed a guided set up and the RoomPerfect Advanced Menu is now available LYNGDORF Advanced Options This section describes the options in the advanced menu which is available after Guided Setup has been c
24. ic Voicing filter press the Info followed by numerical button 0 6 within 2 seconds 8 Analog No function 9 Mute No function 10 Menu Activates or de activates the Menu system on the Main display 11 AMP Selects the remote for operation with a Lyngdorf Amplifier Pre amp 12 RCS Selects the remote for operation with a Lyngdorf Room Processor 13 CD Selects the remote for operation with a Lyngdorf CD Player 14 Tuner No function 15 Channel No function LYNGDORF LYNGDORF 16 Volume Up down No function 17 Up Down Left Right In normal operation mode the Up Down toggles between Bypass Focus and Global filter and the Left Right toggles between Neutral and the available voicings In menu mode they are used for navigation in the menu system Pressing and holding down the Up Down Right Left keys changes some selected values fast 18 Enter Turns the RP 1 On from stand by mode and works as Enter in menu system 19 No Function 11 LYNGDORF Connecting the RP 1 The photos used are only meant as visual aids to show the versatility of the RP 1 Lyngdorf Audio doesn t necessarily carry all other products with the described speci fications in the product assortment Connecting to sources and amplifiers The RP 1 is very simple to hook up There are three basic ways to connect the RP 1 to your system 1 Connect all sources to your
25. ical Specifications Audio Parameter Balanced input connectors 3 pin XLR gold plated Case Gna Pin1 Gna Pin2 Hot Pin3 Cold Balanced input impedance Input sensitivity 4aV 22Vwithhighsens __ DAC Outimpedance 500hm Frequency Response 20 20KHz 0 1dB RoomPerfect Highpass Filter 3dB at 18Hz Analog to Analog Analog to Analog Dynamic Range 113dB Analog to Analog Channel Separation 114dB AC Sweep from 125 16KHz All audio measurements except frequency response are measured with a 20KHz low pass filter in ac cordance with AES 17 Protection Grounding Mains earth chassis and audio AN eee mains transformer Mains Mains voltage range 1o0240VAC5060Hz Mechanical 450mm 17 72 po 355mm 13 98 ne 100mm 3 94 including feet 6 6 Kg 14 6 Ib AAA Shipping weight 9 9 Kg 21 8 lb 2 shipping boxes 35 36 LYNGDORF Technical Assistance For latest version of the firmware the newest version of this document and Questions and Answers please check the Support section on the Lyngdorf Audio website If you have any problems with or questions regarding your Lyngdorf Audio product please contact your nearest Lyngdorf Audio representative or Lyngdorf Audio ApS Denmark E mail info lyngdorf com Web http www lyngdorf com Appendix Voicing Curves For further information on the Voicing setting please refer to the Voicing chapter Mag
26. ne Out terminals When a highpass or lowpass filter has been chosen the Crossover Frequency and Filter Type menus are enabled 27 28 LYNGDORF Crossover Frequency Crossover freq Crossover Frequency is only available when Routing has been setup The Crossover Frequency can be selected anywhere between 40 9999Hz It is very difficult to give exact guidelines to setting a suitable crossover frequency filter type and order since this depends on the exact drivers and configurations Therefore the following recommendations should be seen as a good starting point only In general the recommended crossover frequency between sub woofers and main speakers is be tween 200 400 Hz By using a high crossover frequency the rear wall quarter wavelength reflection is removed from the main speakers If a Lyngdorf Audio boundary woofer is used in a 2 2 set up a crossover frequency of 400 is recom mended due to the high bandwidth of the boundary woofer For conventional active subwoofers with built in low pass filter the recommended crossover frequency is the upper low pass frequency of the subwoofer If at all possible the low pass filter in the subwoofer should be bypassed Due to the quarter wave reflection from the rear wall corresponding to the depth of the subwoofer cabinet we recommend an crossover point at approximately 200 Hz You might experiment with turning the subwoofer so the driver faces the wall in a distance of 5 to
27. nitude dB Magnitude dB Magnitude dB Music 1 Magnitude Response Music 1 10 Hz 100 Hz 1kHz 10ktiz Frequency Hz Relaxed Magnitude Response Relaxed 10 Hz 100 Hz 1kHz 10kHz Frequency Hz Open Air Magnitude Response Open Air 10Hz 100 Hz 1kHz 10kHz Frequency Hz Magnitude dB LYNGDORF Music 2 Magnitude Response Music 2 Magnitude dB 10Hz 100 Hz 1kHz 10kHz Frequency Hz Open Magnitude Response Open Magnitude dB 10Hz 100 Hz 1kHz 10kHz Frequency Hz Soft Magnitude Response Soft 10 Hz 100 Hz 1kHz 10kHz Frequency Hz 37 38 LYNGDORF LYNGDORF 39 LYNGIDORF www lyngdorf com
28. ompleted Here you can change the listening position and add more room measurements check the RoomKnowledge of your current set up and check the RoomCorrection for the different filters Advanced options Measure Room Pos RoomCorrection Change Focus Pos RoomKnowledge If the RP 1 is connected before the volume control of your amplifier e g when using Option 2 or a tape 2 loop as described in Option 3 in the Connecting the RP 1 chapter be aware that the volume control of your amplifier is set at the same level as when making the initial RoomPerfect calibration If you do not remember this setting you will need to perform a new guided setup Change Focus Position If you want to replace your current listening position Focus filter place the microphone correctly in the new listening position and the measurement process can commence as described in the Guided Setup chapter After a successful measurement the message RoomKnowledge XX Measurement ok is displayed Press Enter to continue The message Replace old focus measurement will appear e choose Yes to replace the measurement or e choose No to exit without saving the current measurement Measure Room Pos It is always possible to add more room measurements which can increase RoomKnowledge and there by fine tune both room correction filters Focus and Global Press Enter to start a new room measurement First the volume
29. signals are 25 and 5 seconds respectively You can exit a commenced measurement by pressing the Menu button Do not sit in the listening position during focus measurements The measurement will stop prematurely if an error occurs during the measuring process In this case an error message is displayed Press Enter to continue and Retry focus measurement press Enter is displayed If the error needs correcting this should be done at this point see RoomPerfect troubleshooting thereafter press Enter to retry the measurement The measurement procedure will start again A measurement has ended successfully when the last measuring signal stops and the display shows a RoomKnowledge rating as RoomKnowledge XX Measurement ok Press Enter to continue Room Measurements The number of room positions needed depends on the value of RoomKnowledge if it is below 90 after the third measurement the guide automatically includes extra room measurements until a RoomKnowl edge of 90 or more has been achieved The remaining measurements are to be placed in random positions in the room with random orienta tions of the microphone Choosing these random or arbitrary positions and orientations is easy All you have to do is place the microphone at different positions in the room and with different orientations It is important to perform well spaced measurements to get a covering image of the acoustical properties in the room i
30. wledge 90 means that most of the room s acoustical properties have been learned The more room measurements you add the higher the RoomKnowledge will become The more that the acoustical properties of the room are learned the greater the accuracy of the room correction RoomCorrection The RoomCorrection index is a measure of how much processing is being employed in the room correc tion filter To some extent the RoomCorrection index reflects how audible the correction is However the same amount of processing can sound very different due to placement in frequency of the processing For low values below 10 of the room correction index only subtle correction is needed to the original sound in the room With high room correction index values more extensive processing is employed LYNGDORF Display The sub menus accessible in the Display menu are Display Display Timeout Disp Brightness Display Timeout Display Timeout Display Timeout Display Timeout set up is used for enabling disabling the 10 sec display switch off feature If enabled the Main Display reading will switch off after 10 sec of inactivity from the front panel buttons or re mote Display Brightness Display Brightness Disp Brightness Display Brightness is used to control the brightness of the display The brightness can be set to 25 50 75 or 100 Input Connection Input Connection i The Input Connection c