KitchenAid 8285364 Cooktop User Manual
Contents
1. Installation Instructions 30 76 2 cm and 36 91 4 cm ELECTRIC Built in Ceramic Downdraft Cooktop KitchenAid FOR THE WAY IT S MADE Questions regarding features operation performance parts or service Call 1 800 422 1230 or visit our web site at www kitchenaid com IMPORTANT Read and save these instructions IMPORTANT Installer Leave Installation Instructions with the homeowner Homeowner Keep Installation Instructions for future reference Save Installation Instructions for local electrical inspector s use Write down the model and serial numbers before installing cooktop Both numbers are on the model serial rating plate located on the bottom of the cooktop Model Serial Part No 8285364 Before you start Your safety and the safety of others is very important We have provided many important safety messages in this manual and on your appliance Always read and obey all safety messages This is the safety alert symbol This symbol alerts you to hazards that can kill or hurt you and others All safety messages will be preceded by the safety alert symbol and the word DANGER or WARNING These words mean ADANGER You will be killed or seriously injured if you don t follow instructions AWARNING You can be killed or seriously injured if you don t follow instructions All safety messages will identify the hazard tell you how to reduce th
2. 30 po 33 8 cm 13 5 16 po table de cuission 91 4 cm 36 po trou de 24 8 cm 9 3 4 po l arri re ou sur le c t du placard conduit m tallique diam 15 2 cm 6 po raccord de transition D terminer la longueur quivalente du conduit tuyau PVC ie z Se a conduit m tallique d vacuation La longueur quivalente maximale du murale 15 2 cm 6 po diam 15 2 cm 6 po conduit d vacuation est de 18 3 m 60 pi raccord PVC diam Inscrire le nombre de chaque pi ce et la longueur de conduit 15 2 cm 6 po rectiligne que lon utilisera Multiplier la longueur quivalente par le dalle de b ton nombre de pi ces Additionner les totaux pour obtenir la longueur quivalente totale du syst me 30 5 cm 12 po minimum 40 6 cm 16 po menman tuyau PVC as Ci Son dE Pi ce de Longueur Nbre de Longueur 15 2 cm 6 po 15 2 cm 6 po conduit quivalente pi ces quivalente lt gt 7 longueur totale coude 90 76 2 cm 30 po coude 90 g PVC gout diam maximum PVC gout diam conduit rectiligne par pied lin aire 15 2 cm 6 po 15 2 cm 6 po Gravier ou sable bien tass 8 3 x 25 4 cm 3 1 4 x 10 po 30 5 cm 1 pi tout autour du tuyau er ee foe rond 15 2 cm 6 po 30 5 cm 1 pi option circuit d vacuation install sous une dalle de b ton dans une fosse de flexible 15 2 cm 6 po 61 cm 2 pi fen tre coude coude rond de 15 2 cm 6 po 76 2 m raccord d
3. equivalent vent length is 60 feet 18 3 m The blower housing is set to vent straight out the back from the cooktop To vent down left or right see Installation Step 2 Page 6 This downdraft cooktop is rated at 60 feet 18 3 m of straight vent or the equivalent e If vent length is 10 feet 3 m or less 6 15 2 cm diameter round vent may be used e If vent length is more than 10 feet 3 m use 6 15 2 cm diameter round or 3 1 4 x 10 8 3 x 25 4 cm rectangular vent Thermal breaks In areas of extreme cold weather it may be necessary to provide a short length of nonmetallic duct as close to the wall as possible to prevent thermal conduction along the metal vent For altitudes above 4 500 ft 1372 m reduce recommended vent run by 20 For the most efficient and quietest operation Use 26 gauge minimum galvanized or 25 gauge minimum aluminum metal vent Poor quality pipe fittings can reduce air flow Note Local codes may require a heavier gauge material Flexible metal vent is Not recommended Do Not exhaust more than one downdraft cooktop into a single vent system The length of vent and number of elbows should be kept to a minimum to provide efficient performance The size of the vent should be uniform Use the fewest number of 90 elbows Do Not install two elbows together Make sure there is a minimum of 18 45 7 cm of straight vent between the elbows if more than one elbow is us
4. lectrique N 8285364 2002 KitchenAid Marque d pos e de KitchenAid U S A Emploi licenci par KitchenAid Canada Si la table de cuisson ne fonctionne pas V rifier que le disjoncteur ne n est pas ouvert ou que le fusible n est pas grill V rifier que les connexions des fils sont intactes Voir le Guide d utilisation et d entretien pour la liste de d pannage Si vous avez besoin d assistance Le Centre d assistance la clientele KitchenAid est accessible 24 heures par jour 7 jours par semaine T l phoner au 1 800 422 1230 La communication est gratuite dans les limites du territoire continental des Etats Unis Au Canada composer pour l anglais 1 800 461 5681 ou pour le francais 1 800 461 5708 Ou visitez notre site web www kitchenaid com Lors de l appel il vous faut connaitre le num ro de mod le et le num ro de s rie de la table de cuisson Les deux num ros se trouvent sur la plaque signal tique situ e la base de la table de cuisson KitchenAid APPAREILS MENAGERS Pr par par KitchenAid Benton Harbor Michigan 49022 Si vous avez besoin de service Consulter votre Guide d utilisation et d entretien Dans l ventualit o votre appareil KitchenAid aurait besoin d tre r par t l phonez au marchand chez qui vous avez achet l appareil ou un tablissement de service d sign par KitchenAid Un tablissement de service d sign par KitchenAid
5. 1 4 po couvert par une feuille d acier d au moins 28 MSG acier inoxydable de 0 4 mm 0 015 po aluminium de 0 6 mm 0 024 po ou cuivre de 0 5 mm 0 020 po D gagement minimum de 76 2 cm 30 po entre le dessus de la table de cuisson et le dessous de bois ou de t le non prot g Dimensions de l ouverture decouper 74 9 cm 29 1 2 po table de cuisson de 76 2 cm 30 po 90 2 cm 35 1 2 po table de cuisson de 91 4 cm 36 po largeur de l ouverture profondeur de l ouverture 53 3 cm 21 po espacement minimum de 5 1 cm 2 po du bord avant du comptoir Le comptoir doit tre support en de de 7 6 cm 3 po de l ouverture Choisir l ouverture du conduit requise voir page 4 ou l emplacement d ouverture du conduit d vacuation comptoir 12 7 cm 5 po Installer la boite de connexion du mur arri re dans la partie ombrag e La partie ombrag e plus sombre est pr f rable a plancher lt gt lt gt 27 9 cm 11 po 20 3 cm 8 po Dimensions minimales du placard inferieur largeur de placard inf rieur de 76 2 cm 30 po profondeur de placard inf rieur de 61 cm 24 po profondeur de dessus de comptoir de 63 5 cm 25 po Les dimensions de l ouverture dans le comptoir indiqu es doivent tre utilis es Les dimensions donn es sont les d gagements minimums et fournissent le d gagement requis de 0 cm 0 po Nouvelles installations Suivre les dime
6. 6 inches 15 2 cm from side wall 4 m Connect vent system See Venting requirements Pages 4 5 Use duct tape to seal all joints Vent must end with a wall or roof cap outside the building Electrical connection AWARNING 4 Electrical Shock Hazard Turn power supply off before connecting wires Use 10 gauge solid copper wire Electrically ground cooktop Failure to follow these instructions can result in death fire or electrical shock This cooktop must be connected to a grounded metallic permanent wiring system or a ground connector should be connected to the ground terminal or wire lead on the cooktop This cooktop is manufactured with a frame connected green or bare ground wire Connect the cooktop cable to the junction box through the 1 2 12 7 mm U L listed conduit connector Complete electrical connection according to local codes and ordinances D a Make the electrical connection 1 Disconnect the power supply 2 Remove the junction box cover from junction box inside cabinet 3 Connect cooktop power supply cable to junction box using a U L listed conduit connector Tighten screws on conduit connector 4 Connect the two black wires together with twist on connectors 5 Connect the two red wires together with twist on connectors 6 Complete the electrical connection according to local codes and ordinances See Wire connections chart Wire connections chart cable from
7. conduction thermique le long du conduit m tallique Pour les altitudes sup rieures 1372 m 4500 pi r duire la longueur recommand e du conduit de 20 Pour le fonctionnement le plus efficace et le plus silencieux Utiliser un conduit m tallique galvanis d un calibre minimum de 26 ou en aluminium d un calibre minimum de 25 Les raccords de conduit de mauvaise qualit peuvent r duire le d bit d air Remarque il est possible que les codes locaux exigent un mat riau de calibre plus pais Lutilisation d un conduit flexible m tallique n est pas recommand e Ne pas d charger l air de plus d une table de cuisson aspiration vers le bas dans un seul syst me d vacuation La longueur du conduit et le nombre de coudes devraient tre maintenus au minimum pour une performance efficace La taille du conduit devrait tre uniforme Utiliser le moins de coudes 90 possible Ne pas connecter deux coudes ensemble Veiller ce que deux coudes soient s par s par une section rectiligne d au moins 45 7 cm 18 po si plus d un coude est utilis Les coudes trop rapproch s causent une turbulence excessive qui r duit le d bit d air Ne pas utiliser un coude de 12 7 cm 5 po dans un syst me de 15 2 cm 6 po ou de 8 3 x 25 4 cm 3 1 4 x 10 po Ne pas r duire l arri re un syst me de 12 7 cm 5 po apr s avoir utilis des raccords de 15 2 cm 6 po ou de 8 3 x 25 4 cm
8. d c s un incendie ou un choc lectrique Cette table de cuisson doit tre connect e un c blage m tallique permanent reli la terre ou un conducteur de liaison la terre doit tre connect la borne de liaison la terre ou au fil de liaison la terre de la table de cuisson Cette table de cuisson comporte un fil de liaison la terre vert ou nu connect au ch ssis Connecter le c ble de la table de cuisson la bo te de connexion par l interm diaire d un connecteur de conduit homologation U L de 12 7 mm 1 2 po Compl ter l ensemble du raccordement lectrique conform ment aux dispositions des codes et r glements locaux b a Effectuer le raccordement lectrique 1 2 D connecter l alimentation lectrique ter le couvercle de la bo te de connexion l int rieur du placard Connecter le cable d alimentation lectrique de la table de cuisson la boite de jonction en utilisant un connecteur de conduit homologue U L Serrer les vis sur le connecteur de conduit Connecter ensemble les deux fils noirs avec des connecteurs vissables Connecter ensemble les deux fils rouges avec des connecteurs vissables Compl ter le raccordement lectrique conform ment aux codes et r glements locaux Voir Tableau de connexion des fils Tableau de connexion des fils C ble du s lectionneur fusible bo te de ou du bo tier des disjoncteurs con
9. est mentionn dans les Pages jaunes de votre annuaire telephonique sous la rubrique Appareils lectrom nagers gros appareils service et r paration Imprim aux tats Unis
10. fused disconnect junction or rt breaker box box i white red i wires green or bare ground wire green ground wires appliance cable wire U L listed conduit connector Figure 1 power supply cable from cooktop lf local codes DO NOT PERMIT connecting cooktop ground conductor to neutral white wire in junction box four wire system Connect the green ground power supply cable wire to the ground wire in junction box or other ground connector with twist on connector See Figure 1 Put a twist on connector on end of white wire Replace junction box cover Check operation 6 m Turn on electrical supply 7 Check that cooktop surface elements heat and indicator lights are operating correctly 8 m Check that downdraft vent operates lf the cooktop does not operate disconnect the power supply and check that wire connections have been made correctly cable from fused disconnect or circuit breaker box junction oon lt black red wires wires A g white wire SS SS green ground ean U L listed conduit connector power supply cable from cooktop Figure 2 If local codes PERMIT connecting cooktop ground conductor to neutral junction box wire three wire system 7 Connect the green power supply cable wire to the neutral white wire in junction box with twist on connector See Figure 2 8 Replace junction box cover Y
11. les directives du fabricant de l quipement de chauffage et les prescriptions des normes de s curit comme celles publi es par l American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE et les prescriptions des autorit s r glementaires locales Lors d op rations de d coupage et de per age dans un mur ou plafond veiller ne pas endommager les cablages lectriques ou canalisations qui peuvent s y trouver Le conduit d vacuation associ a un ventilateur doit toujours d charger lair l ext rieur AVERTISSEMENT Pour r duire le risque d incendie utiliser uniquement des conduits m talliques La table de cuisson aspiration vers le bas n est pas approuv e pour utilisation dans les habitations mobiles Des exemplaires des normes indiqu es peuvent tre obtenus aux adresses suivantes National Fire Protection Association Batterymarch Park Quincy Massachusetts 02269 Canadian Standard Association 178 Rexdale Boulevard Etobicoke Toronto Ontario M9W 1R3 Pieces fournies e documentation e couvercle d vent e nettoyant verre Dimensions du produit largeur de 80 cm 31 1 2 po table de cuisson de 76 2 cm 30 po largeur de 95 3 cm 37 1 2 po table de cuisson de 91 4 cm 36 po profondeur 54 4 cm 21 13 16 po profondeur de l enceinte des l ments 74 6 mm 2 15 16 po profondeur du ventilateur de 37 1 c
12. 3 1 4 x 10 po viter de d former manuellement les conduits De telles d formations peuvent restreindre le d bit d air Utiliser les bouches de d charge recommand es pour une performance ad quate Si on utilise une autre bouche de d charge travers le mur ou travers le toit veiller ce que la taille de la bouche de d charge ne soit pas r duite et qu elle comporte un registre antirefoulement Utiliser du ruban adh sif pour conduit pour assurer l tanch it au niveau de chaque jointure Utiliser un produit de calfeutrage pour sceller l ouverture autour de la bouche de d charge travers le mur ou le toit NW N N WN Methodes d evacuation a placard de mur int rieur 8 3 x 25 4 cm 3 1 4 x 10 po coude de transition directement vers l ext rieur l int rieur du mur 4 jusqu au toit ou surplomb placard de mur exterieur Le conduit d vacuation de la table de cuisson peut tre achemin a travers le mur ou le plancher Les m thodes d vacuation courantes et les types de mat riaux n cessaires sont illustr s Avant de d couper les ouvertures de passage du conduit d vacuation v rifier que les d gagements de s curit appropri s seront respect s dans le mur ou le plancher p ninsule ou lot 8 3 x 25 4 cm 3 1 4 x 10 po entre les solives p ninsule retrait du placard l ext rieur 24 4 cm 9 5 8 po table de cuission 76 2 cm
13. SEMENT aspiration par le bas devrait tre Risque possible de d c s ou de loign des sources de courants d air intenses comme les fen tres portes et blessure grave si vous ne suivez pas les instructions puissants ventilateurs ou bouches de Tous les messages de s curit chauffage La table de cuisson devrait tre install e un endroit pratique dans identifient le danger et vous disent comment r duire le risque de la cuisine Une liaison lectrique a la terre est blessure Le non respect des r glements pourrait causer un n cessaire Voir Sp cifications incendie ou un choc lectrique Votre securite et celle des autres est tres importante Nous donnons de nombreux messages de s curit importants dans ce manuel et sur votre appareil m nager Assurez vous de toujours lire tous les messages de s curit et de vous y conformer Voici le symbole de lectriques page 6 Le syst me d extraction de l air doit se terminer l ext rieur Toutes les ouvertures d coup es dans le mur ou dans le plancher au voisinage de l endroit o la table de cuisson sera install e doivent tre scell es C est au client qu incombe la responsabilit de contacter un lectricien qualifi pour s assurer que l installation lectrique est ad quate et Outillage et mat riaux requis _ tournevis Phillips Important Observer tous les codes et r glements en vigueur Le non res
14. agements de s curit appropri s seront respect s dans le mur ou le plancher Ne pas couper les solives ou les poteaux de colombage moins que cela ne soit absolument n cessaire S il faut couper une solive ou un poteau de colombage on doit construire une structure de support Les conduits n cessaires ne sont pas fournis D terminer la m thode d vacuation a utiliser Voir M thode d vacuation ci dessous D terminer ensuite la longueur de conduit quivalente a l aide du tableau la page 5 La longueur quivalente maximale du conduit est de 18 3 m 60 pieds Le bo tier de ventilateur est r gl pour vacuer l air directement l arri re de la table de cuisson Pour vacuer vers le bas vers la gauche ou vers la droite voir Installation page 6 La longueur nominale d un conduit d vacuation rectiligne ou l quivalent pour cette table de cuisson aspiration vers le bas est de 18 3 m 60 pieds e Si la longueur du conduit est 3 m 10 pieds ou moins un conduit rond de 15 2 cm 6 po de diam tre peut tre utilis e Si la longueur du conduit est sup rieure 3 m 10 pieds utiliser un conduit rond de 15 2 cm 6 po ou un conduit rectangulaire de 8 3 x 25 4 cm 3 1 4 x 10 po Isolants thermiques Dans les r gions de froid extr me il peut tre n cessaire d installer une courte section de conduit non m tallique le plus pr s possible du mur pour emp cher la
15. all local codes and ordinances Wire sizes and connections must conform with the rating of the cooktop Copies of the standard listed may be obtained from National Fire Protection Association Batterymarch Park Quincy Massachusetts 02269 Canadian Standard Association 178 Rexdale Boulevard Etobicoke Ontario M9W 1R3 The wiring diagram is located on the bottom of the cooktop Twist on connectors and U L listed 1 2 12 7 mm conduit connector are not provided Installation 1 m Remove shipping materials and tape from cooktop 2 m The blower is set to vent straight out the back of the cooktop To vent to the left side right side or down through the bottom of the cabinet add an elbow to the blower assembly exhaust vent lt may be easier to connect appliance cable to junction box before inserting cooktop into cutout See Electrical connections Page 7 WARNING Excessive Weight Hazard Use two or more people to move and install cooktop Failure to do so could result in back or other injury Lift entire cooktop up from cutout when positioning cooktop in countertop opening 3 m Insert downdraft cooktop into cutout Check that cooktop is centered in cutout front edge of downdraft cooktop is at least 1 1 2 38 1 mm from front edge of countertop and parallel to countertop rear edge of cooktop is at least 3 4 19 1 mm from rear wall as recommended side edge of cooktop is at least
16. base cabinet dimensions See Note for minimum clearances 30 76 2 cm base cabinet width 24 61 cm base cabinet depth 25 63 5 cm countertop depth a aee ae SSS See Countertop opening dimensions that are shown must Minimum distance E X a 53 3 cm be used Given dimensions are minimum clearances and to nearest combustible 0 Not Sea opening depth i n venical inate cooktop to countertop pening dep provide required 0 0 cm clearance extending 18 45 7 cm New installations Follow minimum dimensions given above cooktop N 1 25 4 E S Replacement installation Be sure that front edge of 29 1 2 74 9 em 30 76 2 em cooktop cooktop is at least 1 1 2 38 1 mm back from front 35 1 2 90 2 cm 36 91 4 cm cooktop edge of countertop cutout width If cabinet has drawers drawers will need to be removed and drawer fronts installed on front of cabinet Side clearance 6 15 2 cm minimum clearance between side of cooktop and side wall is recommended for maximum ventilation performance f Rear clearance 3 4 19 1 mm clearance between rear edge of Cutout preparation cooktop and rear wall is recommended Decorative laminate Motor blower clearance 2 51 mm minimum clearance Chamfer all exposed edges to between motor and cabinet is required for proper cooling prevent chipping laminate 6 15 2 cm clearance is recommended for servicing access Cut radius corners and file t
17. bottom of the cooktop KitchenAid HOME APPLIANCES Prepared by KitchenAid Benton Harbor Michigan 49022 If you need service Consult your Use amp Care Guide In the event that your KitchenAid appliance should need service call the dealer from whom you purchased the appliance or a KitchenAid designated service company A KitchenAid designated service company Is listed in the Yellow Pages of your telephone directory under Appliances Household Major Service and Repair Printed in U S A Instructions d installation Table de cuisson encastr e lectrique en c ramique de 76 2 cm 30 po et 91 4 cm 36 po aspiration vers le bas KitchenAid BIEN PENSE BIEN FABRIQU Pour des questions concernant les caract ristiques le fonctionnement la performance les pieces accessoires ou le service composer le 1 800 422 1230 ou consulter www kitchenaid com IMPORTANT Lire et conserver ces instructions IMPORTANT Installateur Remettre les instructions d installation au propri taire de l appareil Propri taire Conserver les instructions d installation pour consultation ult rieure Conserver les instructions d installation l intention de l inspecteur local des installations lectriques Inscire ci dessous les num ros de mod le et de s rie avant d installer la table de cuisson On trouve ces deux num ros sur la plaque signal tique situ e sur le fond de la ca
18. d Do Not have a fuse in the neutral or grounding circuit The downdraft cooktop must be connected to the proper electrical voltage and frequency as specified on the model serial rating plate The model serial rating plate is located on the bottom of the cooktop A four wire or three wire single phase 240 volt 60 Hz AC only electrical supply is required on a separate 30 ampere circuit fused on both sides of the line A time delay fuse or circuit breaker is recommended The fuse size must not exceed the circuit rating of the appliance as specified on the model serial rating plate CONNECT WITH COPPER WIRE ONLY Connected directly to the fused disconnect or circuit breaker box through flexible armored or non metallic sheathed copper cable with ground wire Flexible armored cable should connect cooktop directly to the junction box Fuse both sides of the line Locate the junction box to allow as much slack as possible between the junction box and cooktop so that the downdraft cooktop can be moved if servicing is ever necessary A U L listed 1 2 12 7 mm conduit connector must be provided at the junction box The recommended minimum copper wire size is No 10 gauge However wire sizes and connections must conform to the requirements of the National Electrical Code ANSI NFPA 70 latest edition or CSA Standards C22 1 94 Canadian Electrical Code Part 1 and 22 2 No 0 M91 latest edition and
19. e 45 2 5 pi 30 5 cm 12 po tuyau PVC transition minimum gout diam 15 2 cm 6 po conduit m tallique Ed diam 15 2 cm 6 po bouche de d charge murale coude rond de 15 2 cm 6 po 1 5 m 90 5 pi raccord PVC diam 15 2 cm 6 po coude plat 8 3 x 25 4 cm 3 7 m LD 14x10 p po 12 pi tuyau PVC gout diam 15 2 cm 6 po coude de 90 8 8 x 25 4 cm 1 5 m coude 90 PVC FA 3 1 4 x 10 po 5 pi gout diam fosse de 15 2 cm 6 po fen tre transition rond lt pe SRE PS Gravier ou sable bien tass coude de 90 8 3 x 25 4 cm 2 7 m tout autour du tuyau 3 1 4 x 10 po 15 2 cm 6 po 9 pi 6 po raccord PVC diam d bit d air aea yf min 15 2 cm 6 po 8 3 x 25 4 cm option circuit d vacuation install Gi 3 1 4 x 10 po a 15 2 cm 6 po En RE PE 15 2 cm sous une dalle de b ton transition plat coude de 90 15 2 cm 6 po 1 5 m A 85 254 om 3 1 4 x 10 po 5 pi d bit d air 15 2 cm 6 po 30 5 cm 88 x 254 om 3 1 4 x 10 po 1 pi d bit d air coude de 90 bouche de d charge murale 15 2 cm 6 po 1 2 m 4 pi a 8 3 x 25 4 cm 3 1 4 x 10 po 0 cm 0 pi pe rond 15 2 cm 6 po 0 cm IF 0 pi bouche de d charge travers le toit coude de 90 15 2 cm 6 D bouche de d charge murale 15 2 cm 6 po 1 8 m 6 pi 25 4 x 25 4 cm 10 x 10 po 0 cm CE 0 pi coude 90 3 4 6 m 15 pi isolant th
20. e chance of injury and tell you what can happen if the instructions are not followed Important Observe all governing codes and ordinances Failure to meet codes and ordinances could lead to fire or electrical shock To eliminate the risk of burns by reaching over heated surface units cabinet storage space located above the surface units should be avoided If cabinet storage is to be provided the risk can be reduced by installing a range hood that projects horizontally a minimum of 5 inches 12 7 cm beyond the bottom of the cabinets Proper installation is your responsibility e Make sure you have everything necessary for correct installation e Have a qualified technician install this cooktop e Comply with the electrical specifications on the model serial rating plate Model serial rating plate is located on the bottom of the cooktop Write both numbers down on the front cover now before installing cooktop Downdraft cooktop location should be away from strong draft areas such as windows doors and strong heating vents or fans Locate cooktop for convenient use in kitchen Grounded electrical system is required See Electrical requirements Page 6 Venting system must terminate outdoors All openings in the wall or floor where cooktop is to be installed must be sealed It is the customer s responsibility to contact a qualified electrical installer to make sure that the electrical installati
21. ed Elbows too close together cause excess turbulence that reduces airflow Do Not use a 5 12 7 cm elbow ina 6 15 2 cm or 3 1 4 x 10 8 3 x 25 4 cm system Do Not reduce back to 5 12 7 cm system after using 6 15 2 cm or 3 1 4 x 10 8 3 x 25 4 cm fittings Avoid forming handmade crimps Handmade crimps may restrict airflow Use the recommended vent caps for proper performance If an alternate wall or roof cap is used be certain cap size is not reduced and that it has a backdraft damper Use duct tape to seal all joints in the vent system Use caulking to seal exterior wall or roof Opening around the cap Venting methods 9 5 8 24 4 cm 30 76 2 cm cooktop 13 5 16 33 8 cm 36 91 4 cm cooktop 9 3 4 24 8 cm hole in rear or side of cabinet 3 1 4 x 10 8 3 x 25 4 cm transition elbow The cooktop may be vented through the wall or floor Common venting methods and the types of materials needed are shown Make sure there is proper clearance within the wall or floor for exhaust vent before making cutouts outside wall cabinet inside wall cabinet directly outside inside wall to roof or overhang peninsula peninsula or island transition elbow 3 1 4 x 10 8 3 x 25 4 cm between cabinet toe space floor joists to outside 6 15 2 cm round metal vent Determine equivalent length of vent Maximum 6 15 2cm transition equivale
22. ermique 3 7 m 12 pieds rectilignes 3 7 m 12 pi rond 15 2 cm 6 po bouche de d charge murale Om 0pi Longueur quivalente du 8 3 m 27 pi _ B syst me rond de 15 2 cm 6 po Longueur totale quivalente du syst me d vacuation Remarque On d conseille emploi d un conduit La longueur pour la bouche de d charge murale ou travers le toit d vacuation flexible a d j t incorpor e dans le calcul de la longueur maximale du En cas d utilisation de conduit d vacuation flexible on doit syst me d vacuation Il faut utiliser une bouche de d charge a tenir compte du fait que la longueur effective de un pied travers le mur ou le toit convenable de conduit flexible correspond deux pieds de conduit m tallique rigide La longueur effective des coudes des conduits flexibles est le double de la longueur effective des coudes standard 5 Sp cifications lectriques Si un conducteur distinct de liaison la terre est utilis lorsque le code le permet on recommande qu un lectricien qualifi v rifie que la liaison la terre est ad quate Ne pas utiliser une tuyauterie de gaz pour la liaison la terre En cas d incertitude quant la qualit de la liaison la terre de la table de cuisson consulter un lectricien qualifi Ne pas installer un fusible en s rie avec le conducteur neutre ou le conducteur de liaison la terre La table de cuisson aspiration vers le bas doit tre
23. isse de la table de cuisson N de mod le N de s rie N de pi ce 8285364 Avant de commencer On devrait viter d installer un placard de rangement au dessus des unit s de surface afin d eliminer le risque d incendie ou de brulures lorsqu on essaie d atteindre quelque chose au dessus des unites de surface chauffees Si un placard est necessaire il est possible de reduire le risque en installant sous les placards une hotte de cuisini re qui fait saillie d au moins 5 pouces s curit Ce symbole La responsabilit de la qualit de d alerte de s curit vous l installation incombe au propri taire signale les dangers susceptibles de e V rifier que tout le mat riel n cessaire causer le d c s et des blessures pour une installation correcte est graves vous et d autres Tous les disponible messages de s curit seront e Faire installer cette table de cuisson pr c d s du symbole d alerte de par un technicien qualifi s curit et du mot DANGER ou Res Scifications lectri e pecter les sp cifications lectriques AVERTISSEMENT Ces mots sur la plaque signal tique des num ros signifient de mod le et de s rie La plaque signal tique se trouve sur le fond de la ADANGER table de cuisson Inscrire les deux Risque certain de d c s ou de num ros sur la couverture avant l installation de la table de cuisson blessure grave si vous ne suivez pas les instructions A AVERTIS
24. le des fils et la configuration des connexions doivent satisfaire les prescriptions du Code national des installations lectriques ANSI NFPA 70 ou la derni re dition de la norme ACNOR C22 1 94 Code canadien des installations lectriques partie 1 et C22 2 No M91 derni re dition et les prescriptions de tous les codes et r glements locaux en vigueur On peut obtenir des exemplaires des normes mentionn es aupr s de National Fire Protection Association Batterymarch Park Quincy Massachusetts 02269 Association canadienne de normalisation CSA 178 Rexdale Boulevard Etobicoke Ontario M9W 1R3 Le sch ma de c blage se trouve la base de la table de cuisson Les connecteurs vissables et les connecteurs de conduit 12 7 mm 1 2 po homologation UL ne sont pas fournis Installation 1 m Enlever les mat riaux d exp dition et le ruban adh sif de la table de cuisson 2 m Le ventilateur est r gl pour vacuer l air directement l arri re de la table de cuisson Pour vacuer l air du c t gauche du c t droit ou vers le bas travers le plancher du placard ajouter un coude au montage du ventilateur d vacuation ll est possible qu il soit plus facile de connecter le cable de l appareil m nager la bo te de connexion avant d introduire la table de cuisson dans l ouverture Voir Raccordement lectrique page 7 AVERTISSEMENT Danger de poids excessif Deux pers
25. m 14 5 8 po cable d alimentation lectrique de 91 4 cm 3 pi de long install l usine Dimensions de d gagement Minimum de 76 2 cm 30 po table de cuisson de 76 2 cm 30 po Minimum de 91 4 cm 36 po table de cuisson de 91 4 cm 36 po Ds plus haut que 45 7 cm 18 Voir la remarque pour les degagements minimums Distance de s paration minimale par rapport la surface verticale des mat riaux combustibles la plus proche jusqu 45 7 cm 18 po au dessus de la table de cuisson es profondeur de l ouverture 53 3 cm 21 po Nu Ne pas sceller la table de cuisson au comptoir 25 4 mm 1 po 74 9 cm 29 1 2 po table de cuisson de 76 2 cm 30 po 90 2 cm 35 1 2 po table de cuisson de 91 4 cm 36 po largeur de l ouverture D gagement lat ral D gagement minimum de 15 2 cm 6 po recommand entre le c t de la table de cuisson et le mur lat ral pour une ventilation maximale D gagement arri re Un d gagement de 19 1 mm 3 4 po est recommand entre le bord arri re de la table de cuisson et le mur arri re D gagement de moteur soufflerie D gagement minimum de 51 mm 2 po entre le moteur et le placard est requis pour un refroidissement ad quat Un d gagement de 15 2 cm 6 po est recommand pour l acc s de service Minimum de 61 cm 24 po lorsque le fond du placard de bois ou de m tal est prot g par un panneau ignifuge d au moins 6 4 mm
26. nexion i fil la terre nu ou vert fil de liaison la noirs terre du c ble d alimentation de l appareil connecteur de conduit Figure 1 c ble d alimentation lectrique de la table de cuisson Lorsque les codes locaux NE LE PERMETTENT PAS le raccordement du conducteur de liaison la terre au conducteur neutre blanc de la bo te de connexion syst me quatre fils 7 Connecter le fil vert de liaison la terre du c ble d alimentation au fil vert de la bo te de connexion ou autre connecteur de liaison la terre au moyen d un connecteur vissable Voir Figure 1 8 Visser un connecteur sur l extr mit du fil blanc 9 R installer le couvercle de la boite de connexion Verifier le fonctionnement 6 m R tablir le courant lectrique 7 m V rifier que les l ments de la surface de la table de cuisson chauffent et que les t moins lumineux fonctionnent correctement 8 m Verifier que le syst me d aspiration vers le bas fonctionne Si la table de cuisson ne fonctionne pas d connnecter la source de courant lectrique et v rifier que les connexions des fils ont t effectu es correctement homologu U L c ble du s lectionneur fusible ou du bo tier des disjoncteurs bo te de connexion fils fils rouge ne noirs A fil blanc fil de liaison la terre du c ble de conduit d alimentation homologu de l appa
27. nsions minimales donn es Installation de remplacement S assurer que le bord avant de la table de cuisson se trouve a au moins 38 1 mm 1 1 2 po derri re le bord avant du comptoir Si le placard comporte des tiroirs il faudra enlever les tiroirs et installer des devants de tiroir sur le devant du placard Preparation de l ouverture Stratifi d coratif Chanfreiner tous les bords expos s pour viter d corner le stratifi Arrondir les coins et limer pour obtenir des bords sans asp rit s et pour pr venir le fendillement Prescriptions concernant le syst me d vacuation Le syst me doit d charger l air l ext rieur Ne pas terminer le conduit d vacuation au dessus d un plafond ou dans un autre espace ferm Ne pas utiliser une bouche de d charge murale de 10 cm 4 po normalement utilis e pour un quipement de buanderie Utiliser un conduit m tallique seulement Exception voir Option circuit d vacuation install sous une dalle de b ton ci dessous Un conduit m tallique rigide est recommand Ne pas utiliser de conduit flexible m tallique ou de plastique Pour r duire le risque d incendie et vacuer l air ad quatement veiller d charger l air l ext rieur Ne pas d charger l air dans les murs plafonds ou greniers vides sanitaires ou garages Avant de d couper les ouvertures de passage du conduit d vacuation verifier que les d g
28. nt length of vent is 60 ft 18 3 m wall round PVC 6 15 2 cm cap sewer pipe me ae List the number of each piece and length of straight vent you will use Multiply the equivalent length by the number of pieces Add the totals y 6 15 2 cm to get the total equivalent length of your system 12 30 5 cm 16 40 6 cm round PVC minimum maximum coupling RER ED Vent Equivalent No of Total 6 15 2 cm 6 15 2 cm Piece Length Pieces Equivalent dala as round PVC Length Length COUPIING sewer pipe ak neal ae on straight vent per lineal foot a 6 15 2 cm 15 PE n 1 ft 30 5 cm round 90 PVC Tightly pack gravel or sand round 90 cal ae Sa CRS ee UBL CL sewer pipe elbow completely around pipe PVC sewer 6 15 2 cm round 1 ft 30 5 cm peonon 2H 61 em optional vent arrangement under 6 15 2 cm flexible 2 ft 61 cm concrete slab elbow 6 15 2 cm round 45 elbow 2 5 ft 76 2 m 12 30 5 cm 6 15 2 cm round transition minimum PVC sewer pipe 6 15 2 cm round metal vent 6 15 2 cm round PVC coupling 6 15 2 cm round 90 elbow 5 ft 1 5 m flat elbow 3 7 m 6 15 2 cm round sewer pipe 6 15 2 cm round 3 1 4 x 10 8 3 x 25 4 cm 5 ft 90 elbow 1 5 m eg 8 3 x 25 4 cm 12 ft A O1 3 window 90 PVC sewer transition to round well lt 42 gt pipe elbow 3 1 4 x 10 8 3 x 25 4 cm 106 7 cm Tightly pack gra
29. o smooth edges and to prevent Note 24 61 cm minimum when bottom of wood or metal cabinet is cracking protected by not less than 1 4 6 4 mm flame retardant millboard covered with not less than No 28 MSG sheet steel 0 015 0 4 mm stainless steel 0 024 0 6 mm aluminum or 0 020 0 5 mm copper 30 76 2 cm minimum clearance between the top of the cooking platform and bottom of unprotected wood or sheet metal 3 Venting system requirements Venting system must terminate to the outside Do Not terminate the vent system in an attic or other enclosed space Do Not use 4 inch 10 cm laundry type wall caps Use metal vent only Exception See optional venting under a concrete slab in Venting methods below Rigid metal vent is recommended Do not use plastic or metal foil vent To reduce risk of fire and to properly exhaust air be sure to vent air outside Do Not vent exhaust air into spaces within walls or ceilings or into attics crawl spaces or garages Before making cutouts make sure there is proper clearance within the wall or floor for the exhaust vent Do Not cut a joist or stud unless absolutely necessary If a joist or stud must be cut then a supporting frame must be constructed Vent materials needed for installation are not supplied Determine which venting method to use See Venting methods below Next determine the equivalent vent length using chart on Page 5 The maximum
30. on is correct and to make sure the electrical installation follows the National Electrical Code ANSI NFPA 70 latest edition or CSA Standards C22 1 94 Canadian Electrical Code Part 1 and C22 2 No 0 M91 latest edition and all local codes and ordinances Tools and materials needed for installation Phillips screwdriver caulking gun with weatherproof caulking tape measure ss AT 7 y ay LL TT i safety piers yh glasses Y Not shown e wall or roof cap not supplied e metal vent e twist on connectors and 1 2 UL listed conduit connector Number and size will depend on your installation See Electrical connection Page 7 WARNING To reduce the risk of fire electric shock or injury to persons observe the following Installation work and electrical wiring must be done by qualified person s in accordance with all applicable codes and standards including fire rated construction Sufficient air is needed for proper combustion and exhausting of gases through the flue chimney of fuel burning equipment to prevent back drafting Follow the heating equipment manufacturer s guideline and safety standards such as those published by the American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE and the local code authorities When cutting or drilling into wall or ceiling do not damage electrical wiring and other hidden utilities D
31. onnes ou plus doivent d placer et installer la table de cuisson aspiration vers le bas Le non respect de cette instruction peut causer une blessure au dos ou d autres blessures Soulever toute la table de cuisson lors du positionnement dans l ouverture du comptoir 3 m Ins rer la table de cuisson aspiration vers le bas dans louverture V rifier que la table de cuisson est centr e dans l ouverture le bord avant de la table de cuisson aspiration vers le bas se trouve au moins 38 1 mm 1 1 2 po du bord avant du comptoir et parall le au comptoir le bord arri re de la table de cuisson se trouve au moins 19 1 mm 3 4 po du mur arri re tel que recommand le c t de la table de cuisson se trouve au moins 15 2 cm 6 po du mur lat ral 4 m Connecter le syst me d vacuation Voir Prescriptions concernant le syst me d vacuation pages 4 et 5 Avec du ruban adh sif pour conduit sceller toutes les jointures Le conduit d vacuation doit se terminer par une bouche de d charge travers le mur ou le toit l ext rieur du b timent Raccordement electrique AVERTISSEMENT 4 Risque de choc lectrique D connecter le courant lectrique avant d effectuer le raccordement des fils Utiliser un fil en cuivre solide de calibre 10 La table de cuisson doit tre lectriquement reli e la terre Le non respect de ces instructions peut provoquer un
32. ou have just finished installing your new KitchenAid downdraft cooktop To get the most efficient use from your new cooktop read your Use amp Care Guide Keep Installation Instructions and Guide close to cooktop for easy reference Cooktop removal If removing the cooktop is necessary for cleaning or maintenance 1 Disconnect electrical supply 2 Disconnect vent duct system 3 Lift cooktop out of countertop to complete cleaning or maintenance After cleaning and maintenance 1 Reinstall cooktop in cutout 2 Check that front edge of cooktop is parallel to front edge of countertop 3 Connect vent duct system 4 Connect electrical supply Part No 8285364 2002 KitchenAid Registered Trademark Trademark of KitchenAid U S A KitchenAid Canada licensee in Canada If cooktop does not operate Check that circuit breaker is not tripped or the house fuse blown Check that wire connections are intact See Use and Care Guide for troubleshooting list If you need assistance The KitchenAid Consumer Assistance Center is open 24 hours a day 7 days a week Call 1 800 422 1230 The call is free within the continental United States In Canada call 1 800 461 5681 for English and 1 800 461 5703 for French Or visit our web site at www kitchenaid com When you call you will need the cooktop model number and serial number Both numbers can be found on the model serial rating plate located on the
33. pect des codes et r glements pourrait tre la cause d un incendie ou d un choc lectrique perceuse manuelle ou lectrique pistolet d application pour produits de calfeutrage et d tanch it Non illustr s e conduit m tallique e connecteurs vissables et connecteurs de conduit 12 7 mm 1 2 po homologu s UL Le nombre et la cisaille de ferblantier 9 lectrique page 7 e bouche de d charge murale ou par le toit non fournie taille d pendront de votre installation Voir Connexion en conformit avec les prescriptions du Code national des installations lectriques ANSI NFPA 70 derni re dition ou des normes ACNOR C22 1 94 du Code canadien des installations lectriques partie 1 et C22 2 N 0 M91 derni re edition et avec les prescriptions de tous les codes et r glements locaux en vigueur AVERTISSEMENT Pour r duire le risque d incendie choc lectrique ou blessure respecter les instructions suivantes Tout travail d installation ou c blage lectrique doit tre r alis par une personne qualifi e et respecter des prescriptions de tous les codes et normes applicables y compris les codes du b timent et de protection contre les incendies Une quantit d air suffisante est n cessaire pour une bonne combustion et pour l vacuation des gaz par le conduit de chemin e de quipement de combustion pour emp cher le retour d air Respecter
34. raccord e une tension lectrique et fr quence appropri es tel que pr cis sur la plaque signal tique des num ros de mod le et de s rie Cette plaque est situ e la base de la table de cuisson Un circuit distinct de 30 A 240 V 60 Hz CA seulement monophas a trois ou quatre fils est n cessaire On recommande l emploi d un fusible ou d un disjoncteur sur les deux conducteurs La capacit du fusible ne doit pas d passer la demande de courant maximale de l appareil indiqu e sur la plaque signal tique des num ros de mod le et de s rie EFFECTUER LE RACCORD UNIQUEMENT DES CONDUCTEURS EN CUIVRE La table de cuisson devrait tre directement reli e un coupe circuit avec fusible ou un disjoncteur par l interm diaire d un c ble flexible conducteurs de cuivre blind ou gaine non m tallique a fil de liaison la terre Le c ble blind flexible devrait tre connect directement la bo te de connexion Fusionner les deux c t s du conducteur Placer la boite de connexion pour permettre autant d cart que possible entre la bo te de connexion et la table de cuisson pour que la table de cuisson aspiration vers le bas puisse tre d plac e si un entretien devient n cessaire On doit installer un connecteur de conduit de 12 7 mm 1 2 po homologation U L la bo te de connexion On recommande un conducteur de cuivre de calibre minimum de 10 Toutefois la tail
35. reil U L connecteur c ble d alimentation lectrique Figure 2 de la table de cuisson Lorsque les codes locaux PERMETTENT le raccordement du conducteur de liaison la terre de la table de cuisson au fil neutre blanc de la bo te de connexion syst me trois fils 7 Connecter ensemble le fil vert du c ble d alimentation et le fil neutre blanc de la bo te de connexion l aide d un connecteur vissable Voir Figure 2 8 R installer le couvercle de la bo te de connexion Vous avez termin l installation de votre nouvelle table de cuisson KitchenAid aspiration vers le bas Pour obtenir l utilisation la plus efficace de votre nouvelle table de cuisson veuillez lire le Guide d utilisation et d entretien Conservez les instructions d installation et le Guide a proximite de la table de cuisson pour en faciliter la consultation D pose de la table de cuisson S il est n cessaire d enlever la table de cuisson pour le nettoyage ou l entretien 1 D connecter l alimentation lectrique 2 D connecter le syst me d vacuation 3 Soulever la table de cuisson hors du comptoir pour effectuer le nettoyage ou l entretien Apres le nettoyage et l entretien 1 R installer la table de cuisson dans louverture 2 S assurer que le bord avant de la table de cuisson est parall le au bord avant du comptoir 3 Connecter le syst me d vacuation 4 Connecter l alimentation
36. ucted fans must always be vented to the outdoors WARNING To reduce the risk of fire use only metal ductwork This downdraft cooktop is Not approved for use in mobile homes Copies of the standards listed may be obtained from National Fire Protection Association Batterymarch Park Quincy Massachusetts 02269 Canadian Standard Association 178 Rexdale Boulevard Etobicoke Toronto Ontario M9W 1R3 Parts supplied e literature pack e vent cover e glass cleaner Product Dimensions Cutout Dimensions v 29 1 2 74 9 cm 30 76 2 cm cooktop 31 1 2 80 cm 30 76 2 cm cooktop 35 1 2 90 2 cm 36 91 4 cm cooktop 37 1 2 95 3 cm 36 91 4 cm cooktop cutout width width cutout depth 2 5 1 cm minimum space to front edge of countertop Countertop must be supported within 3 7 6 cm of cutout 21 13 16 54 4 cm depth 2 15 16 74 6 mm burner box depth Select required duct cutout see Page 4 for exhaust duct cutout location N 14 5 8 37 1 cm countertop blower housing depth 3 ft 91 4 cm long power supply cable 5 12 7 cm factory installed Install rear wall junction box in shaded Clearance Dimensions TNT shaded area is 30 76 2 cm min 30 76 2 cm cooktop preferred 36 91 4 cm min 36 91 4 cm cooktop when higher than 18 45 7 cm Ba floor 11 27 9 cm 8 20 3 cm S Minimum
37. vel or sand EC 15 2 cm 30 elbow 15 2 cm Max completely around pipe air flow min 6 15 2 cm round 3 1 4 x ss 8 3 x 25 4 cm to PVC coupling gE HK ares optional vent arrangement through transition to flat window well under concrete slab 15 2 cm to 3 1 4 x 10 5 ft A 3 x 25 4 cm 90 elbow air flow 15 2 cm to an x 10 8 3 x 25 4 cm air flow _ 3 1 4 x 10 8 3 x 25 4 cm 6 15 2 cm 90 elbow A 4 ft 1 2 m cs 6 15 2 cm round VB 6 15 2 cm r 90 elbows roof cap 6 15 2 cm 10 x 10 25 4 X 25 4 cm wall cap C 6 ft 1 8 m thermal break as o 6 15 2 cm round 90 elbows 3 15 ft 4 6 m 12 feet 3 7 m straight 12 ft 3 7 m l Total equivalent vent system length Wall cap Oft 0 m Equivalent length of 271t 8 3 m Length for required wall roof cap has already been incorporated 6 15 2 cm round system into rating for maximum vent system length suitable wall roof cap must be used Note Flexible metal vent is Not recommended If it is used calculate each foot 30 cm of flexible vent as two feet 61 cm of straight metal vent Flexible metal elbows count twice as much as standard elbows Electrical requirements If codes permit and a separate ground wire is used it is recommended that a qualified electrician determine that the ground path is adequate Do Not ground to a gas pipe Check with a qualified electrician if you are not sure cooktop is properly grounde
Download Pdf Manuals
Related Search
Related Contents
Manual de usuario IBM TN5250 Network Router User Manual User`s manual "TwinFresh Comfo" ( PDF 11,49Mb ) SIMSCRIPT II.5 User`s Manual SERVICE MANUAL - mitsubishitech.co.uk HEX36 User Manual Hotpoint DISHWASHER SDL 510 User's Manual Phosphate Diammonique XS TRIGEAR OWNERS MANUAL Copyright © All rights reserved.