Keurig B150 Coffeemaker User Manual
Contents
1. KEURIG B150 Series Commercial Brewer Direct Plumb Kit Welcome Keurig Authorized Dealer This manual provides e Installation of the Direct Plumb Kit DPK that allows you to connect your customer s B150 brewer to municipal or independently pumped water supply e Maintenance Mode diagnostics that will provide you with system information and tools so that you can fully diagnose any problems at the customer s site e Instructions on how to descale the brewer in the event of problems associated with hard water P N 60 201142 000 Rev A 10 09 B150 Direct Plumb Unit Installation Instructions The B150 brewer is designed to be easily transformed from the as purchased Pour Over configuration to a plumbed unit Reconfiguration is designed to be easily and quickly accomplished by a technician using only a 2 Phillips screw driver It is advised that prior to beginning installation that all water be drained from the system using the drain tubes located at rear of brewer see Page 8 for Draining Instructions The brewer MUST also be disconnected from AC power supply during DPK installation 1 Disconnect the brewer from AC power and drain the brewer s Hot Water Tank as detailed in instructions shown on Page 8 2 Remove the Cold Water Tank CWT that came with brewer FIGURE 1 3 You will now need to remove two covers to properly connect the DPK to the B150 Brewer Turning the drained brewer on its left side locate and remove the
2. 2 screws located below that Cold Water Tank For easy identification the screws are located within indented surfaces on the Base Plate FIGURE 2 _ FIGURE 1 4 Remove and reserve the screws The Connection Access Plate can now be removed FIGURES 3 amp 4 i 3 FIGURE 3 FIGURE 4 5 On the side of the brewer locate the Connector Cover Remove and reserve the screw Remove the Connector Cover and expose DPK Interface Connector FIGURES 5 amp 6 FIGURE 5 FIGURE 6 6 Make the electrical connection between the DPK CWT and the brewer body The Connector Cover has an alternate position that allows for cable exit and reattachment to the Brewer Body FIGURES 7 amp 8 FIGURE7 FIGURE 8 7 Install DPK and secure to Brewer Base using the 2 screws that were previously used for the Connection Access Plate FIGURE 9 FIGURE 9 8 The B150 Direct Plumbed Unit is now ready to be connected to AC Power and filtered water supply in accordance with local Building Code rules and regulations Filter Requirements The Keurig B150 brewer system when used with Direct Plumb accessory requires the use of a water filtration system to optimize the coffee flavor and brewer reliability Two mounting holes with screws have been provided on the back of the brewer for this purpose Keurig requires the use of an external water filter such as the Omnipure KQS8A to maintain warranty A filter kit part number 5025
3. Access Panel removed Purpose Maintenance This section describes the Maintenance Mode and key sequences for entry into this mode for the B150 Brewer Maintenance Mode Layout Entry From STANDBY press all 4 corners of the touchscreen Upper Left Right and Lower Left Right in any order within 3 seconds releasing after each touch l Screen Screen 2 Life 10 Screen 10 11 Screen 3 Screen 4 Screen 5 years Screen 6 Screen 7 Screen 8 Screen 9 NOTE Progress from screen to screen using the flashing Brew Button Software Version Total Brew Count Postfill Timeouts Add2 Timeouts Add4 Timeouts Add6 Timeouts Add8 Timeouts Dispense Timeouts Over Pressure Events Top of Tank Events Run Hours 4 oz Brew Count 6 oz Brew Count 8 oz Brew Count 10 oz Brew Count 12 oz Brew Count Brew Button Cont Buttons control Turning Pump On Off Brew Button Cont Brew Pump Vent Valves Buttons control Opening Closing the Valve e g v8 25 Max 999 999 25 x Max 65535 Max 65535 Max 65535 Max 65535 Max 65535 Max 65535 Max 65535 Max 65535 Max 999 999 114 Max 65535 Max 65535 Max 65535 Max 65535 Max 65535 Buttons control Brew Pump On
4. Off amp Opening Closing the Valve Touchscreen Calibration Press Brew button to exit OR touch display to start calibration IF Cal Passes exit If it fails give another opportunity to try Exit back to the Standby State
5. ee times using 40 ounces fresh water per fill Replace Drain Tube Plugs and Access panel Reconnect or resume city water supply and power up the brewer Once the brewer is filled and hot conduct large volume Water Only brews with no K cup potion pack in place until all remnants of the descale solution are not longer evident discarding all liquids into the sink We suggest using the largest brew size to speed the process Remember to open and close the brew handle between each cycle so the blue Brew lights will flash Place the brewer back into service You may need to perform additional rinse cycles if you notice any residual taste Draining Procedure for Hot Water Tank and DPK CWT This procedure is to be performed prior to transportation of unit and when converting brewer between Pour Over usage and Direct Plumb usage NOTICE THIS PROCEDURE MAY RESULT IN THE RELEASE OF WATER AT TEMPERATURES HOT ENOUGH TO RESULT IN BURNS DRAINING PROCEDURE SHOULD ONLY BE PERFORMED BY TRAINED SERVICE PERSONNEL 1 Disconnect the brewer from AC power and if applicable disconnect the Direct Plumb Unit from water supply 2 On rear of brewer locate Access Panel and remove securing screw 3 Lower the appropriate tube remove Plug and drain into appropriate sized container NOTE Hot Water Tank contains 31 oz of water Cold Water Tank contains 35 oz of water 4 Replace Plugs and Access Panel 4 rk ae Drain Tubes with
6. er Reservoir will be clearly evident as shown below Pour Descaling Solution here 6 Reconnect the brewer to AC Power Supply 7 Proceed with descaling procedure as defined below De Scaling Procedure Preparation Prepare at least 40 ounces of a commercial citric acid descale solution You will also need a large ceramic mug a paper cup is not suitable for this procedure and access to a sink for discarding hot liquid FILL AND CLEAN 1 Pour 40 ounces of descale solution into the Cold Water Tank through the Access Port shown above and turn on the brewer the brewer will automatically fill and begin heating 2 When the brewer display shows Ready To Brew place the ceramic mug on the drip tray select the largest brew volume and press the Brew button NOTE Do not use a K Cup portion pack 3 Once the solution begins to exit the brewer lift the Brew Head Handle just enough to halt the brew process and let the brewer sit for 40 minutes in this state 9 At the end of the 40 minutes lower the handle and the brewer should complete the brew do not be concerned if the brewer does not complete the brew Pour the dispensed liquid into the sink Shut down the brewer disconnect it from AC power and drain both Hot and Cold water tanks using the drain tubes located in the back panel of the brewer CAUTION Hot water will be exiting from the Hot Water Tank Manually fill the Cold Water and allow to drain tank thr
7. is available from Keurig This kit contains a Omnipure KQ8A filter filter head and mounting bracket NOTE The KQ8A Filter assembly comes with 1 4 FPT ports for both inlet and outlet and the plumbed water inlet to the brewer is 3 4 Male Garden Hose Thread 1 4 OD LLDPE Linear Low Density Polyethylene tubing is recommended NSF compliant between the filter assembly and the brewer NSF compliant fittings are recommended such as High Density Polypropylene Type NOTE NO PLUMBING CONNECTORS ARE PROVIDED WITH THIS KIT All KQ8A filter cartridges must have a minimum of four gallons of water run through it after mounting to the brewer and before they are connected to the brewer s Inlet Valve at the install location This procedure will prevent fine particles of carbon from entering and clogging the water inlet valve Filter Installation 1 Attach a 4 female garden hose connection to 4 FPT fitting to the Inlet Valve 2 Mount the filter assembly to the brewer using the screws provided on the back of the brewer and connect the filter s Inlet Port to the water supply 3 Flush the filter BEFORE connecting to the Inlet Valve 4 Plug brewer into a dedicated GFCI outlet If the electric circuit is overloaded with other appliances the circuit breaker may trip If possible the brewer should be operating on its own circuit separate from other appliances Never use an extension cord CAUTION This brewer is designed to handle local water p
8. ressures from 40 psig up to 125 psig Consult a licensed plumber for water pressures in your area Use plumbing fittings and tubing specified to withstand 125 psig IMPORTANT NOTICE NOTE FAILURE TO USE A WATER FILTER OR FAILURE TO USE A WATER FILTER IN THE PRESCRIBED MANNER WILL INVALIDATE THE BREWER WARRANTY Descaling Instructions for B150 Brewer with DPK Minerals in drinking water build up on hot surfaces and can build to a point where fluid flow is reduced and other normal brewer functions are hindered When this occurs the brewer must be cleared of these deposits to allow normal brewer function Keurig recommends that the brewer be descaled every 6 months or as needed depending on use and or local water supply mineral content Symptoms of scale build up are slow brewing and or short cups The following procedure outlines the steps required to prepare the brewer for the addition of the descaling solution 1 Unplug the brewer from AC Power Supply 2 Disconnect or interrupt external water supply feeding the brewer 3 Drain the Hot Water and Cold Water Tanks using the drain tubes marked H and C located at rear of brewer per the draining procedure as shown below 4 At the rear left top of the brewer locate and remove two screws which will allow removal of the Top Cover and gain access to the internal Water Reservoir Remove Screws 5 After removal of Top Plate the Descaling Solution Access Port in the Wat
Download Pdf Manuals
Related Search
Related Contents
Ewent EW3965 43 年ぶりに返却されたノート(74 吋望遠鏡取説) TB 9-2330-330-14&P-1 Office des Phabricants d`Univers Singuliers STEVAL-ISB008V1, USB Li-Ion battery charger and gas gauge Pentair Water - Apoolco Pool + Wellness W&T COM-Server - Wiesemann & Theis GmbH PPalmtop - HP Computer Museum PVCO-2000 Visiophone 7 pouces couleur sans fil 11 07 2013 Samsung HW-J450 Vartotojo vadovas Copyright © All rights reserved.