Home

Kenmore 580.513 Dehumidifier User Manual

image

Contents

1. frost build up on the evaporator coil it will automatically 65F E shuts off the compressor The fan will continue 18 C to cycle on and off to draw air across the coil and melt the frost When the coil is defrosted the compressor will automatically restart and dehumidifying resume CHOOSING THE PROPER LOCATION Use the dehumidifier in a basement to help prevent moisture damage Use the dehumidifier in cooking laundry bathing and dishwashing areas that have excessive moisture Use the dehumidifier to prevent moisture damage anywhere books or valuables are stored HSITONAI AUTOMATIC SHUT OFF When the bucket is full or when the bucket is not in the proper position the Bucket Full light turns on and the unit automatically shuts off Also when bucket is out of position the unit will beep 3 times The bucket must be replaced in the proper position for the dehumidifier to work The bucket full light will be on and the dehumidifier will not run if the bucket is not in the proper position The water bucket can be emptied in one of three ways Empty the bucket manually When the bucket is full remove and empty it into a large sink or tub When finished replace it properly NOTE To replace the bucket properly make sure the slots on the back of bucket are positioned correctly Place the dehumidifier directly over drain Open the threaded bucket drain hose connection in the bucket by dri
2. ERMINAL BLOCK 14 A 3531A20014A LAMP NEON 15 A 4838A20005A PANEL CONTROL HUMIDISTAT SWITCH ROTARY Ata HSITDNA DESCRIPTION POWER CORD ASSY CONTROL DEFROST FILTER MECH KNOB ASSY GRILLE ASSY FRONT TANK BUCKET 580 51300 CAUTION When ordering parts use the Kenmore part number not the location number CYCLE PARTS POS NO PART NO DESCRIPTION 1 B 5900A20007A FAN 2 B 4999A10001A SHROUD ASSY 3 B 4681A20040A MOTOR ASSY SINGLE 4 B 4960A20009A MOUNT MOTOR 5 B 5403A10008B CONDENSER ASSY 6 B 5421A10009B EVAPORATOR ASSY 12 580 51300 CAUTION When ordering parts use the Kenmore part number not the location number COMPRESSOR PARTS m zZ 0 E e T POS NO PART NO DESCRIPTION 1 C 3550C 0013A TERMINAL COVER 2 C 6748C 0003A R T C 3 C 6750C 0002S OL P 4 C 2521C A8605 RE COMPRESSOR SET 5 C 1NHA0801206 NUT HEXAGON 1 6 C 4H00972G WASHER 7 C 5040AR4195A ISOLATOR COMP 8 C 5425AP3074C TUBE ASSY CAPILLARY 9 C 5211A30373B TUBE ASSY SUCTION 10 C 5211A30367A TUBE ASSY DISCHARGE 13
3. Owner s Manual Manual del Propietario Kenmoref DEHUMIDIFIER DESHUMIDIFICADOR Model Modelo 580 51300 HSIIDNA i m gt Z O Sears Roebuck and Co Hoffman Estates IL 60179 U S A www sears com TABLE OF CONTENTS TABLE OF CONTENTS iii 2 ADJUSTABLE WATER LEVEL AND WARRANTY inte 2 AUTOMATIC SHUTOFF iii 8 REMOVING AND EMPTYING RECARE T TAE O RAR ates eens bet 3 gu RETTE a THE WATER BUCKET iii 8 mportan ate y nsiructions MAINTENANCE TET TOST T PRE papa 9 ELECTRICAL REQUIREMENTS rere 4 OPERATION E Grille and case ccccceseeeeeeeecceeeeneeeeeees 9 F E Air filter PR OOO TI COIN 9 eatures Cleaning inside the unit wise donee an id dd en ras indi sl 9 Contro Panel icicen 6 General cleaning II III 9 INSTALLING YOUR DEHUMIDIFIER 7 SIONE i Water bucket cleaning 9 eni PROPER LOCATION a AO Ne i S SARE REPAIR PARTS 0 41 ESPANOL dane OR SAAE RODADA RR NRP 14 SERVICE NUMBERS Back Cover WARRANTY FULL ONE YEAR WARRANTY ON DEHUMIDIFIER For one year from the date of purchase if the Dehumidifier is operated and maintained according to the owner s instructions furnished with the product Sears will repair the Dehumidifier free of charge if defective in materials or workmanship FULL FIVE YEAR WARRANTY ON SEALED REFRIGERATION SYSTEM For five years from the date of purchase when this Dehumidifier is
4. abinet paint chips you can touch up the paint with a good grade enamel to prevent rust ISEE WATER BUCKET CLEANING Every few weeks rinse the inside of the water bucket with a mild detergent to prevent growth of mold mildew and bacteria Dehumidifier does not start Dehumidifier does not dry the air as it should Dehumidifier runs too much Frost appears on the coils Fan noise Water on floor wi Possible Causes The dehumidifier power cord is unplugged The fuse is blown or circuit breaker is tripped Water bucket is full Bucket is not installed Did not allow enough time to remove the moisture Airflow is restricted The Dryness Control may not be set high enough Doors and windows may not be closed tightly Clothes dryer may be blowing moisture laden air into the room Room temperature is too low Doors and windows are open Dehumidifier has been recently turned on or room temperature is below 65 F 18 C Air is moving through the dehumidifier Bucket drain hose connection may be loose Water bucket is not all the way in 10 TROUBLESHOOTING a TRA I PSE Problem ws v8 WEL ey did aeg N EE 3 a ra i ARG Pe hope SF ARS WhatiT Do ae Make sure the dehumidifier plug is pushed completely into the outlet Check the house fuse or circuit breaker box and replace the fuse or reset the breaker The dehumidifier automatically tu
5. circumstances cut ami remove or bypass the grounding prong from this plug Power supply cord with 3 prong grounding plug WNT ELECTRICAL INFORMATION The complete electrical rating of your new dehumidifier is stated on the serial plate Refer to the rating when checking the electrical requirements Be sure the dehumidifier is properly grounded To minimize shock and fire hazards proper grounding is important The power cord is equipped with a three prong grounding plug for protection against shock hazards Your dehumidifier must be used in a properly grounded wall receptacle If the wall receptacle you intend to use is not adequately grounded or protected by a time delay fuse or circuit breaker have a qualified electrician install the proper receptacle Do not use an extension cord or an adapter plug m Z O E v E ELECTRICAL REQUIREMENTS OBSERVE ALL LOCAL CODES AND ORDINANCES DO NOT UNDER ANY CIRCUMSTANCES REMOVE THE POWER SUPPLY CORD GROUND PRONG ELECTRICAL GROUND IS REQUIRED ON THIS APPLIANCE A 115 volt 60 Hz AC only 15A fused and properly grounded electrical supply is required A time delay fuse or time delay circuit breaker is recommended Use a dedicated circuit serving only this appliance DO NOT USE AN EXTENSION CORD RECOMMENDED GROUNDING METHOD For your personal safety this appliance must be grounded This appliance has a power supply cord with a 3 prong grounding pl
6. lling a 3 8 10mm to 3 4 19mm hole in the center of the connection Once opened the bucket drain hose connection will continually drain water from the bucket REMOVING AND EMPTYING THE WATER BUCKET Attach a garden hose to the threaded bucket drain hose connection to carry water to the drain When being attached to the bucket drain hose connection be sure the hose doesn t kink or bend It should lie flat from the dehumidifier to the drain MAINTENANCE GRILLE AND CASE To clean the case Use water and a mild detergent Do not use bleach or an abrasive cleaner To clean the grille Use a vacuum with an attachment or brush AIR FILTER The air filter is on the back of the dehumidifier It should be checked and cleaned at least every 30 days or more often if necessary TO REMOVE Flex the filter at the lower right corner and slide the upper right side to the left Release all of the tabs and remove the filter Wash it in warm soapy water Rinse and let the filter dry before replacing it CLEANING INSIDE THE UNIT After removing the air filter clean the coil on the inside with a soft brush to remove any soft and wet soil NOTE Do not allow water to enter the electrical machine compartment through the circular opening behind the coil Do not spray the coil with a hose GENERAL CLEANING Dust the front grille and the side panels with a soft brush or use the dusting attachment of your vacuum If c
7. operated and maintained according to owner s instructions furnished with the product Sears will repair the sealed refrigeration system consisting of refrigerant connecting tubing and compressor motor free of charge if defective in material or workmanship WARRANTY SERVICE IS AVAILABLE BY RETURNING UNIT TO THE NEAREST SEARS SERVICE CENTER IN THE UNITED STATES This warranty applies only while this Dehumidifier is used in the United States This warranty gives you specific legal rights and you may also have other rights which vary from state to state Sears Roebuck and Co D 817WA Hoffman Estates IL 60179 U S A SAFETY IMPORTANT SAFETY INSTRUCTIONS The safety instructions below will tell you how to use your dehumidifier to avoid harm to yourself or damage to your dehumidifier PITT FOR YOUR SAFETY Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance Read product tabels for flammability and other warnings VGN PREVENT ACCIDENTS To reduce the risk of fire electrical shock or injury to persons when using your dehumidifier follow basic precautions including the following Be sure the electrical service is adequate for the model you have chosen F NENNE Avoid fire hazard or electric shock Do not use an extension cord or an adapter plug Do not remove any prong from the power cord Grounding type wall receptacle Do not under any Pa
8. rns off when this occurs Empty the bucket Make sure a bucket in the right place e When first installed allow at least 3 or 4 days to maintain the desired dryness Make sure there are no curtains blinds or furniture blocking the front or back of the dehumidifier Tum the Dryness Control knob closer to the Max position Check that ali doors windows and other openings are securely closed Install the dehumidifier away from the dryer The dryer should be vented to the outside The unit will not operate satisfactorily if the room temperature is below 65 F 18 C Close all doors and windows to the outside This is normal Frost will usually disappear within 60 minutes This is normal Check the hose if one Is attached See the Removing and Emptying The Water Bucket Dehumidifier Model No 580 51300 REPAIR PARTS To order Parts call Toll Free 1 800 4 MY HOME 1 800 469 4663 CAUTION Use the Kenmore part number on all orders not the illustration number OUTER CASE PARTS AND CONTROL PART POS NO 1 A 2 A 3 A 4 A 5 A 6 A 7 A 8 A 9 A 14 A 11 A PART NO 3041AD2007B 4791A10002B 6600A30003C 3090A10001J 6640A40001A 6912A30001F 3720AD3004A 5216A20001A 6600A20001A 9 A 8 A 7 A 5 A 10 A POS DESCRIPTION NO PARTNO BASE ASSY WELD SINGLE 10 A 6411A20001Q BARRIER ASSY 11 A 6614A30001H SWITCH ASSY MICRO 12 A 5230AD3005A CABINET 13 A 4941A30008A T
9. t is full and needs to be emptied It also glows when the bucket is not properly positioned Fan Speed This controls the speed of the airflow Dryness Control This controls the moisture in the room TO OPERATE THE DEHUMIDIFIER 1 Turn the Dryness Control to Off Plug the power cord into an electrical outlet 2 Set the Dryness Control anywhere between Off and Max for normal operation If you need more dehumidification drier air turn the Dryness Control toward Max If you need less dehumidification moister air turn the Dryness Control toward Off 3 Turn the Dryness Control to Off to stop the unit manually 4 To control the speed of air flow turn the Fan Speed toward Low or High Note Be careful not to lose the water bucket This dehumidifier doesn t run if the water bucket is not installed properly INSTALLING YOUR DEHUMIDIFIER Install the dehumidifier on a level floor strong enough to support the unit with a full bucket of water For best performance allow at least 12 18 inches of air space on all sides of the unit for good air circulation Keep all outside doors windows and other openings closed when operating the dehumidifier Humid outdoor air will add to the unit s work load Install your dehumidifier in an area where the temperature will not fail below 65 F 18 C At temperatures below this the coils can become covered with frost ars DEFROST CONTROL When the defrost contro senses
10. ug To minimize possible shock hazard the cord must be plugged into a mating grounding type wall receptacle and grounded in accordance with the National Electrical Code ANSI NFPA 70 latest edition and all local codes and ordinances If a mating wall receptacle is not available it is the personal responsibility and obligation of the customer to have a properly grounded 3 prong wall receptacle installed by a qualified etectrician MAWARNING Electrical Shock Hazard Plug into a grounded 3 prong outlet Do not remove ground prong Do not use an adapter Do not use an extension cord Failure to follow these Instructions can result in death fire or electrical shock 3 prong ding 3 prong groun grounding type wal plug receptacle Ground Power prong supply cord OPERATION FEATURES AAWARNING o i ALE de To reduce the risk of fire electric shock or injury to persons read the important SAFETY Instructions section before operating this appliance Fan speed knob Dryness control knob Empty Bucket indicator Front grille assembly Power cord Cabinet Air filter Water Bucket o NODO Da WD HSIMONA OPERATION Empty Bucket ply Off Max Fan Speed Dryness Control Mateo oc LI CONTROL PANEL Your dehumidifier control panel contains an Empty Bucket indicator a Fan Speed control and a Dryness Control Empty Bucket indicator This light glows when the water bucke