Home
Kenmore 251.90701 Dehumidifier User Manual
Contents
1. __AIR INLET FILTER ONTROL PA 99 08 a E 99 Power On Off 1 Pressing Power button once turns the dehumidifier ON and pressing it again turns the dehumidifier OFF Setting 2 By pressing this button unit will cycle through each setting with every press The order of settings are Auto Humidity Delay Start Cycle Timer Auto Auto 3 When the unit is turned on the unit will default in Auto mode AUTO 3 will be lit and Auto will be displayed in window 7 8 for 10 seconds before returning to the ambient temperature and humidity In this setting humidity level is automatically set for 50 RH Because lower temperatures usually correlate with lower humidity levels the unit will not run frequently At higher temperatures higher humidity is normal so the unit will run more often Humidity In this setting Humidity allows you to manually set the desired humidity level by using the humidity arrows 9 Humidity values are changed in 5 increments ranging from 35 to 70 When in this mode there will not be a setting LED lit When pressing v arrow key when the value is 35 the unit will operate continuously In this continuous operation Cont will be displayed in the window 7 8 for 10 seconds before returning to the ambient temperature
2. Refrigerant R410A 11 29 oz 320g Humidity Humidity Setting 35 70 5 Increments Display Display Range 20 90 1 Increments Current Humidity Temperature Display Range Lo 36 99 F Hi 1 F Increments Current Temp Display Display Range Lo 2 37 C Hi 1 C Increments Current Temp Timed Shut off Setting Range 1Hr 12Hr 1 Hour Increments Fan Motor Speed 3 Speeds Auto High Low Dimensions 15 74x25 59x13 6 in 400x650x346mm Net Weight 49 lbs 22 3Kg Operating Temp 36 F 99 F Drain Pump 12V DC Pump Drain Hose 25 in x 18 ft 6 35x5 486mm 10 WIRELESS REMOTE MONITORING STATION The remote monitoring station is a receiver with a receiving range of only 330 feet in open air with no obstructions Actual receiving range will vary depending on what is in the path of the signal transmitted from the dehumidifier unit Each obstruction roof walls floors ceilings thick trees etc will effectively cut signal range in half Example The wireless remote monitor with a 330 foot range is mounted on an interior wall or placed on a countertop so the signal from the dehumidifier has to pass through one basement wall across the 10 foot width of the room through the room s other wall and then through the floor to the room upstairs where the receiver is located The first wall Setup Guide Insert the batteries in the monitor After the batteries are inserted the Monitoring Station wil
3. DAX emo 99 00 OPERATING BUCKET PUMP Cua a E SENSOR ICON 1 A flashes indicating signal is being received from the main unit If no signal is being received the icon 3 1 appear The temperature 8 and humidity 9 reading will show 00 00 BATTERY POWER INDICATOR 2 displays battery power level from full to low power wal Coo When low indicator will flash N SOUND ON OFF 3 Alert will sound when there is a receiving error and or when BUCKET FULL 6 is activated The sound alert is optional and may be turned off using SWITCH 14 FAN ON INDICATOR 5 rotates when the an is on BUCKET FULL 6 icon flashes when the bucket is full A sound alert is also an option See Sound On Off PUMP ON 7 icon flashes when pump feature has been pre selected on the main unit and the pump is operating TEMPERATURE 8 display shows the current temperature near the main unit SETTING PREFERENCES Press SET 11 once to enter the Setting Mode Press SET 11 and hold down for 3 seconds to check your Receiver version SET HOUR OF DAY 4 Press SET 11 a second time Hour will begin flashing Then press 13 or 12 G to set the hour 1 12 AM or 1 12 PM SET MINUTES 4 Press SET 11 a third time Minutes will begin flashing Use to set the minutes 00 59 24 HOUR CLOCK 4 Press SET 11 a fou
4. Cy F SALIR DE MODO CONFIGURAR presionando SET 11 una sexta vez Your Home For troubleshooting product manuals and home solutions advice manage home www managemyhome com For repair in your home of all major brand appliances lawn and garden equipment or heating and cooling systems no matter who made it no matter who sold it For the replacement parts accessories and owner s manuals that you need to do it yourself For Sears professional installation of home appliances and items like garage door openers and water heaters 1 800 4 MY HOME Call anytime day or night 1 800 469 4663 U S A and Canada www sears com Wwww sears ca f JI Our Home l For repair of carry in items like vacuums lawn equipment and electronics call anytime for the location of the nearest Sears Parts amp Repair Service Center 1 800 488 1222 U S A 1 800 469 4663 Canada www sears com www sears ca To purchase a protection agreement on a product serviced by Sears 1 800 361 6665 Canada Para pedir servicio de reparaci n Au Canada pour service en francais a domicilio y para ordenar piezas 1 800 LE FOYER 1 888 SU HOGARO 1 800 533 6937 1 888 784 6427
5. altas un nivel de humedad m s bajo es m s c modo posiblemente haciendo que la unidad est en marcha de forma continua Pulse SETTINGS 2 una vez ajuste COMFORT 3 est apagado La unidad deshumidificar continuamente CONT aparecer en los visualizadores 7 8 Pulse SETTINGS 2 dos veces ajuste TIMER 5 est encendido TIMER puede ser ajustado pulsando la tecla timer con la flecha hacia arriba 6 de forma repetida para configurar el tiempo operativo para 1 12 horas Utilice la tecla con la flecha hacia abajo para reducir las horas de operaci n Se ver n las horas de operaci n en el visualizador TIME TEMPERATURE 7 Pulse SETTINGS 2 una tercera vez ajuste Humidity 4 est encendido HUMIDITY le permite configurar manualmente el nivel deseado de humedad utilizando las teclas con las flechas de humedad 9 hacia arriba o abajo Se hacen los cambios por incrementos de un 5 el rango de ajustes es el 35 al 70 Se ve el NIVEL DE HUMEDAD en el viualizador 8 Bot n de VELOCIDAD DE VENTILADOR 10 INDICADOR DE VELOCIDAD DE VENTILADOR 11 Presione bot n 1 vez para velocidad de ventilador LOW BAJA 2 veces para velocidad de ventilador HIGH ALTA 3 veces para AUTO AUTO ajusta la velocidad del ventilador autom ticamente seg n el ajuste de humedad INDICADOR DE CUBETA LLENA 12 Cuando la cubeta de colecci n est llena FULL indicador 12 se en
6. Fig 1 Fig 3 CLEANING SIDE GRILLS AND AIR FILTERS 1 Snap open the bottom tab of filter located below the of side grill Fig 1 Grills are located on both sides of unit 2 Pull the filter down and away from unit until it is all the way out Fig 2 Note The filter is extremely flexible This action will not damage the filter 3 Wash with mild detergent Rinse thoroughly Air dry away from direct sunlight 4 Using both hands insert the top edge of the filter into the slot below the side grill and slide into place Fig 3 Snap the bottom tab into the closed position 5 SIDE GRILLS can be cleaned using a vacuum cleaner or a soft brush to remove dust Fig 4 6 SIDE GRILLS can be cleaned using a vacuum cleaner or a soft brush to remove dust CHECK YOUR FILTERS PERIODICALLY TO INSURE PROPER OPERATION Fig 4 CLEANING THE EXTERIOR Clean the exterior using a soft brush or dry towel But do not spray water directly on the exterior CLEANING THE BUCKET Pull the bucket out Lift off bucket cover Fig 1 Clean the inside of bucket every week using mild detergent in order to block buildup of mold and bacteria Fig 2 After cleaning replace the bucket cover and slide the bucket into the unit Fig 3 Check the float switch to make sure it is not obstructed Proper position of the bucket and the float switch is required for the dehumidifier to turn on y TROUBLES
7. Figura 3 4 Reconecte la parte final de la manguera de jard n que tiene el CONECTOR de DRENAJE al deshumidificador Figura 4 luego inspeccione la manguera para asegurarse de que no tenga pliegues u obstrucciones La posici n de la manguera en el drenaje del suelo debe estar a un nivel m s bajo que el CONECTOR de DRENAJE 5 Guarde LA TAPA de DRENAJE para vaciar la cubeta manualmente en el futuro V ase opci n 3 en siguiente p gina 21 OPCIONES DE ELIMINACI N DE AGUA CUIDADO Y MANTENIMIENTO OPCION 3 DRENAJE DE BOMBA 1 Quite La TAPA de DRENAJE de la BOMBA girando en direcci n de las agujas del reloj Enrosque al rev s Figura 1 2 Quite la TAPA del orificio de drenaje tirando hacia fuera mientras este presionando el enganche hacia dentro Figura 2 Guardar la TAPA DEL DRENAJE y el TAP N para usarlos en el futuro LIMPIEZA DEL EXTERIOR da noverrencia Limpie el exterior con un cepillo suave o Desconecte el cable de alimentaci n oalla seca Pero no aplique agua con un del recept culo antes de efectuar alg n atomizador directamente sobre el exterior mantenimiento 3 Introduzca la manguera de Y pulgada proveida en el orificio de la TAPA de DRENAJE Figura 3 4 Introduzca el final de la manguera dentro del orificio de drenaje Figura 4 a continuaci n enrosque la TAPA de DRENAJE en la unidad de nuevo Figura 5 Coloque el otro
8. hose properly connected to the machine and the pump is intended to be used If the pump button is pressed when using other water disposal options E3 Error Message will show on display panel Pump will run automatically whenever the bucket gets full The bucket may not empty completely to protect the pump but once the bucket fills up again the pump will turn on WATER DISPOSING OPTIONS OPTION 1 EMPTYING MANUALLY 1 Pull out the bucket grasping upper and lower handles 2 Carry the bucket by grasping the inside handle of the bucket 3 After emptying the bucket replace the bucket in the dehumidifier NOTE Dehumidifier will not work when the BUCKET FULL light is on or without the bucket properly placed in the unit ds f y j y OPTION 2 GRAVITY DRAIN HOSE Hose Not Provided 1 Take off GRAVITY DRAIN CAP by turning the cap counterclockwise Fig 1 2 Remove DRAIN CONNECTOR from the bucket Fig 2 3 Next screw the DRAIN CONNECTOR to a standard garden hose by turning clockwise Fig 3 4 Reattach the DRAIN CONNECTOR end of garden hose to the dehumidifier Fig 4 then check hose for kinks or obstructions The position of the hose at the floor drain must be lower than DRAIN CONNECTOR OPTION 3 PUMP DRAIN 1 Remove the PUMP DRAIN CAP by turn ing clockwise Reverse thread Fig 1 2 Remove the drain hole PLUG by pulling out while pressing
9. not the compressor The unit will return to dehumidification automatically Move the unit to a level surface This is the normal sound of the refrigerant flowing through the coils Normal sound of expansion and contraction caused by temperature changes Clean the SIDE GRILL and AIR FILTER Although the unit will dehumidify at temperatures below 65 degrees there is a potential for frost to develop which may inhibit the unit s efficiency Normal Compressor and electric motor discharge nominal heat Re install drain hose according to this manual Flatten the hose or remove block age Turn on the pump Re install it according to this manual Flatten the hose or remove block age Water does not drain through pump drain hose Check the connecting hose for tangles or folds Does pump display light appear Re install drain hose according to this manual Flatten the hose or remove blockage Turn on the pump ERROR CODES Check the surrounding area for possible reasons for sudden temperature changes Wait 30 minutes before plugging g the resuming normal If the Error is still indicated please contact your nearest service center Error Error Type Possible Causes Corrective Actions Code EO Temperature 1 Unplug the dehumidifier Sensor 1 Sudden c
10. sea consciente de que las piezas met licas pueden tener bordes afila dos y pueden provocar lesiones Para limpiar la unidad utilice un pa o suave no utilice cera disolventes ni detergentes fuertes como pueden cambiar el color de la unidad o causar da os en la superficie Aseg rese de reemplazar la cubeta debida mente cuando vaya a vaciarla para evitar que el agua caiga al suelo y cause da os en algunos tipos de suelo Puede ser que la funci n de Baja Tempera tura no funcione de forma eficaz si la tem peratura de la sala est por debajo de los 65 F 18 C Las bajas temperaturas po dr an causar que se acumule escarcha so bre las bobinas No coloque ning n animal o planta donde podr a estar expuesto al flu jo de aire directo Esto podr a lesionar al animal o da ar la planta No utilice el agua acumulada en la cubeta para beber No es sanitario y podr a causar una enfermedad Operar la unidad sin filtro provocar fallos en la unidad Inserte el filtro de forma que est bien sujeto Limpielo cada dos sema nas V ase mantenimiento No dejen que los ni os jueguen con este producto REQUISITOS EL CTRICOS OBSERVAR TODOS LOS C DIGOS Y ORDENANZAS NO QUITE BAJO NINGUNA CIRCUNSTANCIA LA PATILLA DE TOMA DE TIERRA DEL CABLE DE ALIMENTACI N SE REQUIERE UNA TOMA DE TIERRA EL CTRICA PARA UTILIZAR ESTE ELECTRODOM STICO SE REQUIERE UNA TOMA EL CTRICA SOLAMENTE CORRIENTE ALTERNA DE 115 VOLTIOS
11. y es posible que adem s tenga otros derechos que var an de estado a estado Sears Roebuck and Co Hoffman Estates IL 60179 Sears Canada Ine Toronto Ontario Canada M5B 2B8 15 INSTRUCCIONES DE SEGURIDAD RTENCIAS IMPORTANTES PARA EL USO DE SU DESHUMIDIFICADOR Para reducir el riesgo de incendio descarga el ctrica lesi n o da o al deshumidificador se deben de seguir estas precauciones de seguridad ADV No colocar el cable de alimentaci n cerca de una estufa No usar un enchufe el ctrico que est cerca de materiales inflamables o combustibles como gasolina propano disolventes etc No desmonte ni modifique partes o compo nentes del deshumidificador Puede causar una descarga el ctrica y fallo del aparato Enchufe el cable de alimentaci n deforma correcta No encienda ni apague la unidad insertando o retirando la clavija No da e el cable ni utilice un cable de alimentaci n no especificado e No modifique la longitud del cable de alimentaci n No comparta el enchufe con otros aparatos Realice siempre la conexi n a un enchufe con toma de tierra Si no hay toma de tierra podr a producirse una descarga el ctrica Desenchufe la unidad si emite un sonido extra o olores o humo No utilice el enchufe si est flojo o da ado No utilice la unidad con las manos mojadas o en un entorno h medo Ventile el rea antes de operar el deshumi dific
12. 60 Hz 15 CON FUSIBLE Y TOMA DE TIERRA ADECUADA Se recomienda un fusible o un cortacircuitos de demora de tiempo Utilice un circuito dedicado a servir este electrodom stico nicamente r Una clavija de 3 patillas con toma de tierra Cable de alimentaci Enchufe el ctrico de 3 patillas con toma de tierra NO UTILICE UN CABLE DE EXTENSI N M TODO RECOMENDADO DE TOMA DE TIERRA Este electrodom stico debe de tener una toma de tierra para su seguridad personal 17 Este electrodom stico tiene un cable de alimentaci n con una clavija de tres patillas con toma de tierra Para minimizar una posible descarga el ctrica el cable debe estar enchufado en un enchufe el ctrico con toma de tierra apropiado que cumpla con la ltima edici n del C digo El ctrico Nacional y todos los c digos y ordenanzas locales Si no se dispone de un enchufe el ctrico de 3 patillas con toma de tierra es la responsabilidad y obligaci n personal del cliente hacer sea instalado por un t cnico cualificado Ah ADVERTENCIA RIESGO DE DESCARGA EL CTRICA Conecte la clavija en un enchufe el ctrico de tres patillas con toma de tierra e No quite la patilla de toma de tierra No utilice una clavija adaptadora de dos patillas e No utilice un cable de extensi n El no seguir estas instrucciones puede resultar en una posible muerte fuego o descarga el ctrica INSTALACION DE SU DESHUMIDIFICADOR Instale el desh
13. 70 Pintas Electr nico R 22 11 29 onzas Ajuste de Humedad 35 70 Rango de Visualizador 20 90 Rango de Visualizador Bajo 36 99 F Alto Comentario Periodo de 24 horas 3209 Incrementos del 5 Incrementos del 1 F Temperatura Actual Rango de Visualizador Bajo 2 37 C Alto Incrementos del 1 C Temperatura Actual Rango de Ajuste 1 hora 12 hora Incrementos de 1 hora 3 Etapas Auto Alto Bajo 15 74 x 25 59 x 13 6 pulgadas 400x650x346mm 49 libras 22 3Kg 36 F 99 F Bomba de Drenaje 12V Corriente Directa Manguera de Drenaje de la Bomba 25 pulgadas x 18 pies 6 35x5 486mm 19 h 4 s 4 4 s s 4 POWER ON OFF 1 Si pulsa el bot n una vez se enciende el deshumidificador ON y si lo vuelve a pulsar se apaga el deshumidificador OFF Cuando la unidad est encendida opera autom ticamente en modo COMFORT 3 AUTO aparecer en los visualizadores 7 8 En esta posici n el nivel de humedad y temperatura est n equilibrados para una comodidad normal A temperaturas bajas la humedad m s alta parecer m s c moda haciendo que la unidad este en marcha con menos frecuencia A temperaturas m s
14. HOOTING Before calling for service try the suggestions below to see whether you can solve your problem without outside help PROBLEMS CHECK POINT SOLUTIONS Dehumidifier does not work when pressing the POWER ON button is the power cord plugged into a grounded 3 prong outlet Is BUCKET FULL light on Does BUCKET FULL light appear after emptying the water bucket Plug the power cord securely into a grounded 3 prong outlet Empty the water bucket and re install Check the float switch to make sure it is free and not obstructed Dehumidifier is operating but the dehumidification function does not work Is the compressor running as well as the fan Is there frost on the coils Loud noise and Is the unit on a level surface or vibration during operation Sounds Sounds like flowing water during and after operation It makes a pinging sound Dehumidification function is inefficient Are the filters and grills dirty Is indoor temperature under 65 F Unit is discharging warm air Check the DRAIN CONNEC TOR Is it installed correctly Water does not drain through hose Check the drain hose for kinks or obstructions is PUMP light on Check the DRAIN CON NECTOR making sure it is installed securely Water does not drain through garden hose Check the garden hose for tangles or folds The unit may be in the defrost mode The fan is running but
15. NOT pay for 1 Expendable items that can wear out from normal use including but not limited to filters belts light bulbs and bags Aservice technician to instruct the user in correct product installation operation or maintenance Aservice technician to clean or maintain this product Damage to or failure of this product if it is not installed operated or maintained according to all the instructions supplied with the product Damage to or failure of this product resulting from accident abuse misuse or use for other than its intended purpose Damage to or failure of this product caused by the use of detergents cleaners chemicals or utensils other than those recommended in all instructions supplied with the product Damage to or failure of parts or systems resulting from unauthorized modifications made to this product Nn OD 0 AO N Disclaimer of implied warranties limitation of remedies Customer s sole and exclusive remedy under this limited warranty shall be product repair as provided herein Implied warranties including warranties of merchantability or fitness for a particular purpose are limited to one year or the shortest period allowed by law Sears shall not be liable for incidental or consequential damages Some states and provinces do not allow the exclusion or limitation of incidental or consequential damages or limitation on the duration of implied warranties of merchantability or fitness so these exclusion
16. R ENCENDIDO 5 gira cuando el ventilador est encendido ICONO CUBETA LLENA 6 parpadea cuando la cubeta est llena Tambi n existe una alerta sonora como opci n V ase Sonido On Off Pilas DX T OPERATING BUCKET rT F Lis 61 CONO BOMBA ENCENDIDA 7 parpadea cuando se ha preseleccionado la funci n de bomba en la unidad principal y la bomba est uncionando TEMPERATURA 8 el visualizador muestra a temperatura actual cerca de la unidad principal HUMEDAD 9 demuestra el nivel actual de humedad cerca de la unidad principal cuando el receptor y la unidad principal est n funcionando correctamente AGUJERO PARA COLGAR 10 para colgar en la pared de forma opcional CONFIGURAR PREFERENCIAS Presione SET 11 una vez y mantenga presionado durante 3 segundos para entrar en Setting Mode CONFIGURAR HORA DEL D A 4 Presione SET 11 una segunda vez Hour empezar a centellear A continuaci n presione 13 o 12 para fijar la hora 1 12 a m o 1 12 p m CONFIGURAR MINUTOS 4 Presione SET 11 una tercera vez Minutes empezar a parpadear Utilice para fijar los minutos 00 59 RELOJ DE 24 HORAS 4 Presione SET 11 una cuarta vez Utilice para ir pasando entre el reloj 12H y 24H FARENHEIT O CELSIO 8 Presione SET 11 una quinta vez Utilice O para ir pasando entre
17. TA INAL MBRICA DE MONITORIZACI N La estaci n de monitorizaci n remota es un receptor con un rango de recepci n de solamente 330 pies al aire libe sin ninguna obstrucci n El rango de recepci n real variar dependiendo de lo que este en la trayectoria de la se al transmitida por la unidad deshumidificadora Cada obstrucci n tejado paredes techos rboles macizos etc va a cortar el rango de se ales a la mitad Ejemplo El monitor remoto inal mbrico con un rango de 330 pies est montado sobre una pared interior o puesto sobre un superficie de tal forma que la se al del humidificador tenga que pasar por una pared del s tano a trav s de la sala de 10 pies de anchura a trav s de la otra pared de la sala y a continuaci n por el suelo para llegar INSTRUCCIONES DE CONFIGURACI N DE RECEPTOR Setup Guide Introduzca las pilas en el monitor Despu s de que las pilas sean insertadas la Estaci n de Monitorizaci n empezar a recibir datos de se al del deshumidificador temperatura humedad etc deber an de estar expuestos en la pantalla del monitor Revise el deshu midificador para averiguar si est funcionan do correctamente si esto no pasa despu s de 2 minutos Quite las pilas del monitor espere un minuto y vuelva a ponerlas a la sala en la planta de arriba donde est localizado el receptor La primera pared va a reducir el rango a 165 pies mientras que la segunda pared reducir el rango a 87 pi
18. Use amp Care Guide Manual de Uso y Cuidado English Espa ol Model Modelo 251 90701 Kenmore Elite midi ss IQ P N J8000004210 Sears Brands Management Corporation Hoffman Estates IL 60179 USA www sears com ain lt Microban TABLE OF CONTENTS Warranty cc cece a a ia 2 Water Disposing Options Package Contents cece 2 Care and Maintenance Safety Instructions eee 3 Troubleshooting 0 00ccc cece eeeeeeeees Installation cece ina 4 Error Codes Product Specifications 10 Electrical Requirements 00000000 00 4 Wireless Remote Station 11 12 Key Features Receiver Setting Instructions 12 Control Panel Spanish Espa ol Dehumidifier Set Up WARRANTY Kenmore Elite Limited Warranty When installed operated and maintained according to all instructions supplied with the product if this appliance fails due to a defect in material and workmanship within one year from the date of purchase call 1 800 4 MY HOME to arrange for free repair If the sealed refrigerant system is defective within five years from the purchase date call 1 800 4 MY HOME to arrange for free repair All warranty coverage applies for only 90 days from the date of purchase if this product is ever used for other than private family purposes Sears Service This warranty covers only defects in material and workmanship Sears will
19. ador Averig e si hay presencia de gas natural o una acumulaci n de otros vapores combustibles No limpie el deshumidificador con agua El agua podr a introducirse en la unidad y degradar el aislamiento dando lugar a una descarga el ctrica Si entra agua en el producto apague el interruptor del deshumidificador y a conti nuaci n desenchufe la unidad No vuelva a enchufar la unidad hasta que haya sido inspeccionado por un servicio de reparaci n autorizado Como el ventilador rota a una velocidad alta durante su operaci n siempre desenchufe el deshumidificador antes de empezar cual quier mantenimiento o limpieza recomendado No bloquee la entrada ni la salida Puede hacer que la unidad falle o que funcione de forma ineficaz 16 No desenchufe la clavija del enchufe tirando del cable Apagando la unidad cuando no est siendo usada ahorrar energ a Desenchu fe el deshumidificador cuando no vaya a uti lizarlo durante un largo periodo de tiempo Aseg rese de que el deshumidificador ten ga la capacidad adecuada para la zona que desea deshumidificar No est dise ado para deshumidificar la casa entera Para un funcionamiento adecuado el deshumidificador se deber a de instalar ni camente sobre un suelo nivelado Cierre todas las puertas ventanas y otras aberturas al exterior de la habitaci n El deshumidificador debe utilizarse en una zona cerrada para ser eficaz Al extraer el filtro
20. ador Kenmore Elite Estaci n Remota de Monitorizaci n 2 pilas 2AAA Gu a de Uso y Cuidado Manguera de Desag e de Bomba de 18 pies GARANT A Garant a Limitada Kenmore Elite Cuando sea instalado operado y mantenido seg n todas las instrucciones prove das con el producto si este electrodom stico falla debido a un defecto en materiales y manufactura dentro de 1 a o despu s de la fecha de compra llame al 1 800 4 MY HOME para concertar la reparaci n gratis Si el sistema refrigerante sellado est defectuoso dentro del periodo de los 5 a os desde la fecha de compra llame al 1 800 4 MY HOME para concertar una reparaci n gratis Si el sistema refrigerante sellado es defectuoso dentro de los cinco anos desde la fecha de compra llame al 1 800 4 MY HOME para concertar una reparaci n gratis En el caso de que el fin con el que se utilice este producto no sea privado y familiar la cobertura de garant a se aplicar solo durante el periodo de 90 dias desde la fecha de compra Esta garant a solamente cubre defectos en materiales y manufactura Sears no pagar por 1 tems prescindibles que pueden desgastarse debido al uso normal incluyendo pero no limitados a filtros cintas bombillas y bolsas 2 Un t cnico de servicio para instruir al usuario sobre la correcta instalaci n operaci n o mantenimiento del producto 3 Un t cnico de servicio para limpiar o mantener este producto 4 Da o a o fallo de este
21. and humidity To leave continuous operation press the arrowa or change the setting Delay Start 5 Unit can be programmed to turn on at a desired delay time by pushing the timer arrows 6 Time can be adjusted in 1 hour increments ranging from 1 to 12 hours Delay time will be shown in window 8 and will count down to start time in 1 hour increments Cycle Timer Setting 4 In this setting the unit will run for either 3 6 or 12 hours then shut off for 3 6 or 12 hours Cycle time can be adjusted by pushing the timer arrow up or down 6 repeatedly to set operating time for 3 6 or 12 hours The cycle timer function will continue until you change the setting or turn the unit off Fan Speed 10 Press Fan Speed to toggle between Auto Low and High fan speeds Speed will be shown in fan speed indicator 11 When AUTO is selected the unit will adjust the fan speed accordingly depending on the humidity level Bucket Full Indicator 12 When the collection bucket is full BUCKET FULL indicator 12 will come on The dehumidifier will not run until the bucket is empty Pump On Off Pump On is an optional setting when using the supplied Y drain hose to remove the collected water in the bucket To turn the pump on off press the Pump Button 14 When the pump is on Pump Display 13 will light on The Pump Display 13 will be off when the pump is off The pump should only be turned on when there is a 1 4 drain
22. beta mientras la bomba est i fata chan e ae A SRS 4 Lave con detergente suave Aclare l deshumidificador deje de funcionar lo totalmente Seque al aire libre fuera de cual producir un mensaje de falla E3 la luz directa del al Interruptor flotante ADEMAS La manguera de desag e de 5 Utilizando ambas manos inserte el borde la bomba no debe estar sumergida en el agua NI a una altura superior al deshu midificador Esto puede causar un flujo al reverso hacia el deshumidificador y superior del filtro en la ranura que est por debajo de la parrilla lateral y deslicelo hasta que llegue a colocarse en su sitio har que ste deje de funcionar lo cual Figura 3 Cierre la leng eta inferior hasta producir un mensaje de falla E3 que llegue a la posici n de cierre de o el aparato se 6 Se pueden limpiar las parillas laterales debe desconectar y reiniciar para que vuelva a funcionar V ase la secci n C digo de Fallas en este manual con una aspiradora o un cepillo suave para quitar el polvo Verifique su filtro peri dicamente para asegurar la operaci n apropiada Figura 4 22 23 SOLUCIONES DE PROBLEMAS Antes de llamar para un servicio t cnico intente las siguientes sugerencias para ver si puede solucionar su problema sin ayuda ajena PROBLEMAS POSIBLES CAUSAS SOLUCIONES El deshumidificador no funciona cuando se aprieta el bot n POWER ON Est enc
23. cender El deshumidificador no funcionar con la cubeta llena PUMP ON OFF 14 Pump On Bomba encendida es un ajuste opcional cuando se utiliza una manguera de drenaje para vaciar el agua acumulada Cuando la bomba est encendida el icono 13 se encender El bot n PUMP 14 siempre debera de estar en posici n OFF salvo cuando se est utilizando la bomba para vaciar el agua acumulada V ase pagina 7 Opci n 3 Si el bot n PUMP est presionado cuando se est usando otras opciones de vaciamiento de agua aparecer E3 Mensaje de error en el visualizador 20 OPCIONES DE ELIMINACI N DE AGUA OPCION 1 VACIAR MANUALMENTE 1 Tire de la cubeta agarrando las asas superior e inferior 2 Lleva la cubeta agarrando el asa interior de la cubeta 3 Despu s de vaciar la cubeta coloque de nuevo la cubeta en el deshumidificador NOTA El deshumidificador no funcionar cuando la luz de advertencia de cubeta llena BUCKET FULL est encendida o cuando la cubeta no ha sido colocada en la unidad de forma adecuada OPCION 2 MANGUERA DE DRENAJE DE GRAVEDAD No Se Incluye La Manguera de Jard n 1 Quite LA TAPA de DRENAJE de GRAVEDAD girando el tap n en direcci n opuesta a las agujas del reloj Figura 1 2 Quite el CONECTOR de DRENAJE de la cubeta Figura 2 3 Luego enrosque el CONECTOR de DRENAJE en una manguera de jard n est ndar gir ndolo en direcci n a las agujas del reloj
24. es Teniendo en cuenta la sala de 10 pies queda un m ximo de 77 pies de rango de se al restante Subiendo por el suelo ha reducido el rango efectivo a unos 38 pies T picamente esta prestaci n es suficiente para la mayor parte de las casas de construcci n con marco sin embargo ciertos materiales pueden reducir el rango todav a m s Revestimiento exterior met lico estuco y algunos tipos de vidrio pueden reducir el rango de se al hasta un 75 comparado con la reducci n en un 50 t pica de la mayor parte de obstrucciones Es posible recibir una se al a trav s de estos materiales aunque el rango m ximo va a ser mucho m s peque o debido a su tendencia a absorber o reflejar una porci n mucha m s grande de la se al del deshumidificador NOTA Si no est recibiendo una se al apropiada despu s de los procedimientos de ajuste es posible que tenga que mover el monitor m s cerca a la unidad principal ICONO de SENSOR 1 parpadea indicando que se est recibiendo la se al de la unidad principal Si no se recibe ninguna se al no aparecer el icono INDICADOR de CARGA de PILA 2 muestra el nivel de carga de la Pila desde llena a baja ma CoL a El indicador parpadeara cuando esta bajo SONIDO ON OFF 3 Sonar el alarma cuando hay un error en la recepci n y o cuando CUBETA LLENA 6 est activada El sonido de alerta es opcional y se puede apagar mediante el INTERRUPTOR 14 INDICADOR DE VENTILADO
25. eta mal instalado 2 Obstrucci n en el sistema de la manguera de desague 3 Flujo al reverso de agua por la manguera de desag e de la bomba 4 Manguera de desag e de la bomba instalada incorrectamente 5 Bomba de desag e da ada 1 Desconectar el deshumidificador 2 Chequear el rea circundante para encontrar las razones del cambio brusco de temperatura 3 Esperar 30 minutos antes de volver a enchufar el deshumidificador y hacerlo funcionar normalmente 4 Si el c digo de falla persiste p ngase en contacto con el centro de servicios m s cercano 1 Desconectar el deshumidificador 2 Quitar la cubeta 3 Verificar que no haya algo obstruyendo la conexi n de la base de la bomba o de la cubeta 4 Volver a instalar la cubeta asegur ndose de hacerlo correctamente 5 Verificar que la manguera de desague de la bomba no est estrechada u obstruida 6 Asegurarse que la manguera de desague de la bomba no est sumergida en el agua ni a una altura superior a la del deshumidificador esto puedo causar un flujo al reverso de agua de la manguera al deshumidificador 7 Sacar y reinstalar la manguera de desag e de la bomba asegur ndose que sta sea instalada correctamente 8 Enchufar el deshumidificador y prenderlo 9 Si el c digo de falla persiste p ngase en contacto con el centro de servicios m s cercano 25 ESTACI N REMO
26. final de la manguera en el sitio por el cual usted quiere que pase el agua a un drenaje de suelo un contenedor de agua o mediante una ventana del s tano que da al exterior E LIMPIEZA DE LA CUBETA Saque la cubeta del la unidad Quite la tapa de la cubeta Figura 1 Limpie el interior de la cubeta con detergente suave cada semana para bloquear la acumulaci n de moho y bacterias Figura 2 Despu s de limpiar vuelva a colocar la tapa de la cubeta en su A La bomba puede subir el agua hasta me SS LATERAL Y sitio dentro de la unidad Figura 3 Revise el una altitud de 15 pies por encima de la interruptor flotante para asegurarse de que unidad Inspeccione la manguera para Figs 1 Abra la leng eta inferior del filtro no est obstruido Se requiere que la cubeta ver si hay pliegues u otras obstrucciones i localizado por debajo de la parilla lateral Y el interruptor flotante est n en su posici n 5 En el caso improbable de que se Figura 1 Las parrillas son situadasen Correcta para que el deshumidificador se RE la Wea ee a ambos lados de la unidad ponga en marcha vibraciones durante la operaci n de la bomba reconecte la a para 2 Tire del filtro hacia abajo y hacia fuera de a que la bomba siga eliminando agua la unidad hasta que est totalmente fuera automaticamente de la unidad Figura 2 A Nota El filtro es extremadamente flexible i j ADVERTENCIA No quitar la Esta acci n no da ara el filtro
27. hange 2 in the E1 Defrost surrounding 3 Sensor temperature dehumidifier back in an operation E2 Humidity 2 Faulty sensor 4 Sensor E3 Pump Drain 1 Improper 1 Unplug the dehumidifier bucket 2 Remove the bucket PRODUCT SPECIFICATIONS installation 3 2 Blockage to drain hose system 3 Back flow of water through 5 pump drain hose 4 Improper pump drain hose installation 5 Faulty drain pump Classification Spec Model 251 90701 Power Supply AC 115V 60 Hz Moisture Removal 70 Pint 33 liters Control Type Electronic Check to make sure that there is nothing blocking the connection at the base of the pump or the bucket 4 Reinstall the bucket taking care that it is installed properly Check to make sure that the pump drain hose is not crimped or blocked 6 Check to make sure that the pump drain hose is not both under water and sitting at a height above the dehumidifier this can cause a back flow of water from the hose to the dehumidifier 7 Remove and reinstall the pump drain hose taking care that the pump drain hose is installed properly Plug the dehumidifier in and restart If the ES error is still indicated please contact your nearest service center Remark 24 Hour Period
28. he dehumidifier in the basement to help prevent moisture damage in the kitchen laundry room bathroom and spa exercise areas that have exces sive moisture to prevent moisture damage anywhere books or valuables are stored during construction or remodeling to reduce drying time for drywall and paint AUTOMATIC SHUT OFF When the bucket is full or when the buck et is not in the proper position the Bucket Full light goes on and the unit automati cally shuts off The bucket must be replaced in the proper position for the dehumidifier to work The light will stay on and the dehu midifier will not run if the bucket is not in the proper position e The dehumidifier will shut off once the desired humidity setting is reached plus or minus 5 Relative Humidity RH To reduce the risk of fire electric shock or injury to persons read the important SAFETY INSTRUCTIONS found on page 3 before operating this appliance KEY FEATURES OF YOUR DEHUMIDIFIER HANDLE f fas GRAVITY DRAIN PUMP DRAIN SIDE GRILL 4 BUCKET CASTER Al An e lt Microban y antimierobial product protection Microban antimicrobial protection inhibits the growth of odor causing bacteria on the dehumidifier Bucket MICROBAN is a registered trade mark of Microban Products Company aca CONTROL PANEL SIDE GRILL
29. hufado el cable de ali mentaci n en un enchufe de tres paletas con toma de tierra Est encendida la luz de adver tencia de BUCKET FULL Aparece la luz de advertencia de BUCKET FULL despu s de vaciar la cubeta de agua El deshumidificador funciona pero no la funci n de deshumidificaci n Ruido y o vibraciones fuertes durante su operaci n Sonidos La funci n de deshumidificaci n es ineficiente La unidad est echando aire caliente El agua no drena por la manguera Est n funcionando tanto el compresor como el ventilador Hay escarcha en las bobinas Est la unidad en una superfi cie nivelada Suena como un flujo de agua durante y despu s de su ope raci n Hace un sonido met lico Est n los filtros y parrillas sucios Est la temperatura interior por debajo de los 65 F Revise el CONECTOR de DRENAJE para averiguar que est instalado de forma segura Revise la manguera de jard n para ver si hay enredos o pliegues El agua no drena por la manguera de jard n Revise la manguera de conexi n para ver si hay enredos o pliegues Aparece la luz de bomba Enchufe de forma segura el cable de alimentaci n en un enchufe de tres paletas con toma de tierra Vaci y vuelva a colocar la cubeta de agua Revise el interruptor flotante para averiguar si est libre y no obstruido Puede ser que la unidad est e
30. in on the coupler Fig 2 Keep the DRAIN CAP and PLUG for future use 3 Feed the 1 4 inch hose provided through the hole in the DRAIN CAP Fig 3 4 Insert the end of hose into the drain hole Fig 4 then screw DRAIN CAP back onto the unit Place the other end of the hose in the location you want the water to go to a floor drain a water container or through a basement window to the outdoors Pump can lift water up to 15 feet above the unit Check hose for kinks or other obstruction ml Der ARI Fig 3 Fig 4 5 Keep the DRAIN CAP for future use when 5 In the unlikely event the hose comes emptying bucket manually loose during pump operation due to vibration re attach hose to continue automatic pump removal of water i CAUTION Do not remove the bucket while the pump is operating This will cause the dehumidifier to stop operat ing and result in an E3 error message ALSO The pump drain hose should not be both under water AND at a height that is above the dehumidifier This can cause a back flow to the dehumidifier and cause the dehumidifier to stop work ing resulting in an E3 error message Following an E3 error the unit must be unplugged and reset to operate See Error Code section of this manual CARE AND MAINTENANCE A warne Disconnect power supply cord from receptacle before performing any maintenance 3 y j y A
31. it is loose or damaged Do not operate or plug in unit with wet hands or in a wet environment Ventilate area before operating dehumid ifier Check for the presence of natural gas or the buildup of other combustible vapors Do not clean the dehumidifier with water Water may enter the unit and degrade the insulation resulting in an electrical shock If water enters the product turn off the dehumidifier s power switch then unplug the unit Do not plug in unit until it has been inspected by an authorized repair service Because the fan rotates at high speed during operation always unplug dehumid ifier before attempting any recommended maintenance or cleaning Do not block the inlet or outlet lt may cause unit to fail or to operate inefficiently Do not remove plug from outlet by pulling on the cord When not in use turning the unit off will save energy Unplug the dehumidifier when not using for long periods of time e When removing the filter be aware that some metal parts may have sharp edges and may cause injury e Do not use the water collected in the bucket for drinking purposes lt is not sanitary and could cause illness e Do not allow children to play with this product Tips e Auto is the suggested setting for typical everyday use e Make sure the dehumidifier is the correct size for the area you want to dehumidify It is not designed to dehumidify the entire house e For proper operatio
32. l start receiving signal data from the dehumidifier temperature humidity etc should be displayed on the monitor s screen If this doesn t happen after 2 minutes check the dehumidifier to make sure it is operating properly Remove the batteries from the monitor wait a minute then replace Batteries will reduce the range to 165 feet and the second wall will reduce the range to 87 feet Factoring in the 10 foot room this leaves a maximum of 77 feet of remaining signal range Passing up through the floor has now reduced the effective range to 38 feet Typically this allowance is enough for most frame constructed homes however certain materials can reduce range even further Metal siding stucco and some types of glass can reduce signal range by as much as 75 compared to the 50 reduction typical of most obstructions It is possible to receive a signal through these materials however maximum range will be much less due to their tendency to absorb or reflect a much larger portion of the dehumidifier s signal NOTE You may have to move the monitor closer to the main unit if it is not receiving a proper signal following set up procedures OPERATING Sa TEMPERATURE 09 00 BUCKET PUMP Receiver On Battery Strength Sound Alert Or HUMIDITY 9 Wall Hanger O Set Button Sound On Off 11 RECEIVER SETTING INSTRUCTIONS
33. ly cord with a 3 prong grounded plug To minimize possible shock hazard he cord must be plugged into a matching grounded electrical outlet that complies with the latest edition of the National Electrical Code and all local codes and ordinances If a grounded 3 prong electrical outlet is not available it is the personal responsibility and obligation of the customer to have one installed by a qualified electrician Y ELECTRICAL SHOCK HAZARD Plug into a grounded 3 prong outlet Do not remove ground prong Do not use a two prong adapter Do not use an extension cord Failure to follow these instructions can result in death fire or electrical shock INSTALLING YOUR DEHUMIDIFIER Install the dehumidifier on a level floor strong enough to support the unit with a full bucket of water For best performance allow at least 12 18 inches of air space on all sides of the unit for good air circulation Keep all outside doors windows and other openings closed when operating the dehumidifier Humid outdoor air will add to the unit s workload e Leave the dehumidifier in an upright position for 30 minutes before turning on DEFROST OPERATION The dehumidifier has a built in defrost control that senses frost buildup on the evaporator coils During defrosting the compressor will automatically turn off the fan will continue running to defrost the coils CHOOSING THE PROPER LOCATION Use t
34. n modo de deshelar Funciona el ventilador pero no el compresor La unidad volver a la deshumidificaci n autom ticamente Mueva la unidad a una superficie nivelada Este es el sonido normal que hace el refrigerante cuando fluye por las bobinas Es el sonido normal de la expansi n y la contracci n causadas por cambios en la temperatura Limpie la PARRILLA LATERAL y el FILTRO DE AIRE La unidad no funciona de modo eficaz por debajo de los 65 F Normal El compresor y el motor el ctrico desprenden un calor minimo Coloque de nuevo la manguera de drenaje segun las instrucciones de este manual Aplane la manguera o quite el bloqueo Ponga la bomba en marcha Col quela de nuevo seg n las instrucciones de este manual Aplane la manguera o quite el bloqueo El agua no pasa por la manguera de drenaje de bomba Revise la manguera de conexi n para ver si hay enredos o pliegues Aparece la luz de bomba Coloque de nuevo la manguera de drenaje seg n las instrucciones de este manual Aplaste la manguera o quite el bloqueo Ponga la bomba en marcha 24 Codigo de Falla EO E1 E2 E3 Clase de Falla Detector de temperatura Detector de escarcha Detector de humedad Desagtle de la bomba Posibles Causas Actividad Correctiva 1 Cambio brusco de la temperatura ambiente 2 Detector da ado 1 Cub
35. n the dehumidifier should only be placed on a level floor e Close all doors windows and other open ings to the room The dehumidifier must operate in an enclosed area to be effective e To clean use a soft cloth do not use wax thinners or strong detergents as they may change the color of the unit or cause surface damage e Be sure to replace the bucket properly after emptying to prevent water from collecting on the floor causing damage to some types of flooring e Do not put a pet or house plant where it will be exposed to direct air flow This could injure the pet or plant e Operation without filter will cause unit failure Insert the filter securely Clean it every two weeks See maintenance ELECTRICAL REQUIREMENTS OBSERVE ALL LOCAL CODES AND ORDINANCES DO NOT UNDER ANY CIRCUMSTANCES REMOVE THE POWER SUPPLY CORD GROUND PRONG ELECTRICAL GROUND IS REQUIRED ON THIS APPLIANCE A 115 VOLT 60Hz AC ONLY 15A FUSED AND PROPERLY GROUNDED ELECTRICAL SUPPLY IS REQUIRED A time delay fuse or time delay circuit breaker is recommended Use a dedicated circuit serving only this appliance 3 prong grounded plug Grounded 3 prong Power supply cord electrical outlet DO NOT USE AN EXTENSION CORD RECOMMENDED GROUNDING METHOD For your personal safety this appliance must be grounded This appliance has a power supp
36. or en un s tano para ayudar a evitar da os por humedad en una cocina zonas de lavadero ba os y zonas de ejercicio que tienen humedad excesiva para evitar da os por humedad en lugares que se guardan libros u objetos de valor durante una construcci n o remodelaci n para reducir el tiempo necesario para secar el muro de mamposter a y pintura APAGUE AUTOM TICO Cuando la cubeta est llena o no est en la posici n adecuada se encender la luz de advertencia de cubeta llena y se apaga la unidad autom ticamente e La cubeta debe colocarse en la posici n correcta para que el deshumidificador funcione Si la cubeta no est en la posici n correcta la luz permanecer encendida y el deshumidificador no funcionar El deshumidificador se apagar solo una vez que llegue al nivel de humedad deseado DRENAJE DE GRAVEDAD DRENAJE DEBOMBA PARRILLA LATERAL 7T CUBETA e qhi eere RUEDECILLA Sk _ PANEL DE CONTROL PARRILLA LATERAL FILTRO DE ADMISI N DE AIRE ESPECIFICACIONES DEL PRODUCTO Clasificaci n Modelo Suministro de Energ a Capacidad de Humedad Tipo de Control Refrigerante Visualizador de Humedad Visualizador de Temperatura Temporizador de Apague Velocidad de Motor del Ventilador Dimensiones Peso Neto Temperatura Operativa Espec 251 99701801 CA 115V 60 Hz
37. producto si no ha sido instalado operado o mantenido seg n todas las instrucciones prove das con este producto 5 Da o a o fallo de este producto debido a accidente abuso mal uso o uso para fin que no sea el adecuado 6 Da o a o fallo de este producto debido al uso de detergentes limpiadores qu micas o utensilios que no sean los recomendados en todas las instrucciones proveidas con este producto 7 Da o a o fallo de partes o sistemas que resulten de modificaciones no autorizadas hechas a este producto Descargo de responsabilidad de garant as impl citas limitaci n de remedios El nico y exclusivo remedio del cliente bajo esta garant a limitada ser la reparaci n del producto tal y como est estipulado aqu en la misma Garant as implicadas incluyendo garant as de comerciabilidad o adecuaci n para un fin particular est n limitadas a un periodo de un a o o a el periodo m s corto que sea permitido por ley Sears no se responsabilizar por da os imprevistos o consecuentes Algunos estados y provincias no permiten la exclusi n o limitaci n de da os incidentales o consecuentes o la limitaci n de la duraci n de garant as impl citas de comerciabilidad o adecuaci n por lo tanto es posible que estas exclusiones o limitaciones no se apliquen a usted Esta garant a solamente se aplica mientras este electrodom stico sea usado en los Estados Unidos o Canad Esta garant a le otorga derechos legales espec ficos
38. rth time Use HO to toggle between 12H 24H clock FARENHEIT OR CELSIUS 8 Press SET 11 a fifth time Use to toggle between C F EXIT SETTING MODE by pressing SET 11 a sixth time HUMIDITY 9 display shows the current humidity level near the main unit when re ceiver and main unit are operating properly HANGER HOLE 10 for optional wall mounting 12 Guia de Uso y Cuidados Deshumidificador con Estaci n Remota Inal mbrica de Monitorizaci n Modelo 251 99701801 ADVERTENCIA Lea y siga todas las reglas de seguridad e instrucciones antes de operar este equipo Sears Roebuck and Co Hoffman Estates IL 60179 U S A www sears com NDICE Contenido del Paquete 14 Opciones de Eliminaci n de Agua 21 22 cl puis ieee S n a 15 Cuidados y Mantenimiento 00000000000 23 Instrucciones de Seguridad o o 16 Soluciones de Problemas 0 0 0 00 24 Requisitos El ctricos ee C digos de Fallas 25 Instalaci n 00000 ee Estaci n Remota Inal mbrica de Caracter sticas Principales Monitorizaci n oooocccccncnonononononanannonononononos 26 Especificaciones del Producto 19 Instrucciones de Configuraci n Panel de Control cece 20 del Receptol occcccccccicicicinincncncncncncnnnno 26 27 Configuraci n del Deshumidificador 21 Servicio Sears Contra Portada CONTENIDO DEL PAQUETE e Deshumidific
39. s or limitations may not apply to you This warranty applies only while this appliance is used in the United States or Canada This warranty gives you specific legal rights and you may also have other rights which vary from state to state Sears Roebuck and Co Hoffman Estates IL 60179 Sears Canada ine Toronto Ontario Canada MSB 2B8 PACKAGE CONTENTS Batteries 2 AAA Use amp Care Guide Kenmore Elite Dehumidifier Remote Monitoring Station 18 ft Pump Drain Hose 2 INSTRUCTIONS IMPORTANT CAUTIONS FOR USING YOUR DEHUMIDIFIER A To reduce the risk of fire electrical shock injury or damage to the dehumidifier these safety precautions must be followed Safety Do not place the power cord near a heater Do not use an electrical outlet near flammable or combustible materials such as gasoline propane paint thinners etc Do not disassemble or modify dehumidifier parts or components It may cause electric shock and failure Plug in the power cord properly Do not turn the unit on and off by inserting or pulling out the power plug Do not damage the power cord or use an unspecified power cord Do not modify power cord length Do not share the outlet with another appliance Always plug into a grounded outlet Not grounding unit may cause electrical shock Unplug the unit if it emits strange sounds odors or smoke Do not use an electrical outlet if
40. umidificador sobre un suelo nivelado suficientemente fuerte para sostener la unidad con su cubeta llena de agua Para un mejor rendimiento deje un espa cio de al menos 12 18 pulgadas a cada lado de la unidad para permitir una buena circulaci n de aire Cuando est operando el deshumidi ficador mantenga cerradas todas las puertas ventanas y otras aberturas al exterior El aire h medo del exterior va a incre mentar el volumen de trabajo de la uni dad Para una eficiencia m xima instale su deshumidificador en un rea donde la temperatura no baje a menos de 65 F A temperaturas de menos de 65 F las bobinas del evaporador pueden cubrirse de escarcha as reduciendo el ren dimiento del deshumidificador Coloque el deshumidificador en posici n vertical durante un periodo de 30 minutos antes de ponerlo en marcha OPERACI N DE DESHIELO El deshumidificador tiene un control de deshelar incorporado que detecta la acumulaci n de escarcha sobre las bobinas del evaporador Durante el deshielo el compresor se apagar autom ticamente el ventilador que se encuentran en la p gina 3 Ah ADVERTENCIA Para reducir el riesgo de incendio descarga el ctrica o lesi n a personas antes de operar este electrodom stico lea las importantes INSTRUCCIONES de SEGURIDAD seguir funcionando para deshelar las bobinas UBICACI N ADECUADA DEL DESHUMIDIFICADOR Utilice el deshumidificad
41. www sears ca Registered Trademark Trademark of KCD IP LLC in the United States or Sears Brands LLC in other countries Marca Registrada Marca de F brica de KCD IP LLC en Estados Unidos o Sears Brands LLC in otros pa ses MC Marque de commerce Marque d pos e de Sears Brands LLC
Download Pdf Manuals
Related Search
Related Contents
AVer F50 DPD Series Dual Pyrometer Gauge User Manual Humidificador YZ450FT Owner's Service Manual Les clés d`un contrôle précis du niveau en canal ouvert Open Old Town Canoe Co. 164 Boat User Manual USER`S MANUAL MODEL: 5970-80 MODEL Bedienung - Windhager User Manual: Hand-held Analyzer Types 2250 and ENG Copyright © All rights reserved.
Failed to retrieve file