Home
Hunter Fan 44110 Thermostat User Manual
Contents
1. Day Temperature Program Number and other feature information as required Up and Down Keys Keys for changing the Temperature setting Also used for increasing and decreasing selections in the Time Program and Span Low Battery Indicator functions Flashes when batteries need to be replaced Program Key Used for entering and modifying Programs Use with the Up and Down keys to set times and temperatures Press when in Clock setting mode to select between 12 and 24 hour clock modes System Switch Selector switch for Heat Cool and Off Fan Switch Fan switch for Automatic or Continuous fan Filter Key Resets filter change operation counter to zero Battery Compartment Front access allows easy insertion of two AA 1 5V batteries Hold Return Key Used for setting a permanent vacation hold and for returning to the normal display from Day amp Time setting Programming or Span setting modes Reset Press with a paper clip to resetthe Battery Release Lever Push thermostat and return to power up settings to pop batteries loose ENERGY STAR PARTNER As an ENERGY STAR Partner Hunter Fan Co has determined that this programmable thermostat meets the ENERGY STAR guidelines for energy efficiency on CHANGE FOR THE a la A BETTER WITH EL ENERGY STAR a eer INSTALLATION What You Need This thermostat includes two 8 slotted screws and two wall anchors for
2. HOLD return will be displayed on the LCD and the Program number will disappear E Follow the Temporary Manual Override instructions above to change the Perma nent Manual Override temperature i by pressing for less than 1 second return To end the Permanent Manual Override o a display will be canceled return E You can confirm the held set temperature oO m S U Z a BI Press again The thermostat will return to the current program and the HOLD Filter Change Indicator Your thermostat measures the number of hours your heating and cooling system has been in use To maximize your system s performance and energy efficiency change or clean your filter regularly E When the total system runtime for heat MTWTH F SA SU SET TEMP and cool reaches 400 hours the Filter 7 A Change Indicator will flash as a reminder HA 7 to check your system s filter MI After changing or cleaning the system s filter press and hold the Filter Key for 3 seconds The display will blink and the timer will be reset to zero o gt A P FILTER ps COOL TEMP Note Pressing the Filter Key at any time for less than 3 seconds will cause the Filter indicator to appear on the LCD This is only to confirm key operation and the timer is not affected unless the key is held for greater than 3 seconds SPAN Setting Mode Your thermostat is set at the factory to cycle at 1 F 0 5 C above a
3. Your system will remain shut off until the batteries are replaced Note The thermostat will still keep the current time and your programs in memory until new batteries are installed After confirming that new batteries have been inserted the thermostat will return to normal operation ED Auto Recovery Hunter s Auto Recovery feature meets the ENERGY STAR guidelines for energy efficiency by allowing the heating or cooling system to recover gradually from an energy saving setpoint temperature to a comfort setpoint temperature Auto Recovery calculates how early to turn your system back On so that the room temperature is already comfortable by the start of the comfort temperature program period Auto Recovery works in both Heat and Cool modes E When the thermostat is in Auto Recovery mode the display will alternate RECO with time and the program indica tor will flash E Auto Recovery can be disabled by sliding the Recovery switch on the circuit board to disable HEAT TEMP E Auto Recovery will not operate if Permanent hold or Tem porary hold is in operation E Auto Recovery can be canceled manually if HOLD RETURN is pressed during the recovery process BI Auto Recovery will be canceled and change to Temporary Manual Override mode if the setpoint is adjusted during the recovery process Error Mode If the thermostat is unable to control your system due to an unexpected battery problem the thermosta
4. a Set amp Save Programmable Thermostat Owners Manual Model 44110 ED Congratulations Your new Hunter thermostat will provide years of reliable service By saving energy your thermostat will pay for itself during its first season of use Thank you for buying a Hunter product Please read this manual for complete instructions on installing and operating your thermostat If you require further assistance call Hunter Technical Support at 1 888 830 1326 from 8am to 5pm Central Time Before starting remove the mylar label from the LCD display IMPORTANT INFORMATION 1 This thermostat is designed to work on the following systems Gas Standing Pilot Gas Electronic Ignition Gas Fired Boilers Gas Milivolt Systems Oil Fired Boilers Oil Fired Furnace Electric Furnace Electric Air Conditioning This thermostat will NOT control single stage or multi stage heat pumps or 110 220 V baseboard electric heating systems 2 Temperature Range This thermostat can be programmed between 45 F and 95 F 7 C and 35 C It will display room temperatures from 30 F to 99 F 0 C and 37 C HI will be displayed if the temperature is higher than 99 F 37 C and LO will be displayed if the temperature is lower than 30 F 0 C This thermostat will automatically cut off in Heat mode if the temperature rises above 95 F 35 C and automatically cut off in Cool mode if the temperature drops below 4
5. 4 minute delay before the system turns On wait and check Compressor protection delay 3 Check your circuit breakers and switches to ensure there is power to the system 4 Replace batteries 5 Make sure your furnace blower door is closed properly 6 If your system only uses 4 wires be sure the jumper wire is installed between the RC and RH terminals Erratic Display 1 Press the reset button once with a small pin and hold for two seconds Then reprogram If unit continues to operate 1 Replace unit in the Off position Thermostat permanently 1 Replace unit reads HI LO or ERR If you experience any other problems call 1 888 830 1326 from 8 AM to 5 PM Central Time for technical assistance O 2003 Hunter Fan Company 41638 01 06 30 03 Hunter Fan Company 2500 FRISCO AVENUE MEMPHIS TN 38114
6. C 10 00 pm 60 F 16 C 82 F 28 C E All 7 days of the week have the same default programs Personal Program Schedule E You can revise the factory programs to match your own schedule Use this Personal Pro gram Schedule to determine which times and temperature settings match your comfort and energy saving requirements Use a pencil so you can revise your records each time you change your program settings Heating Monday Time Time Time Time Friday Temp Temp Temp Temp Saturday Time Time Time Time Sunday Temp Temp Temp Temp Cooling Monday Time Time Time Time Friday Temp Temp Temp Temp Time Temp Saturday Time Time Time Sunday Temp Temp Temp Revising Programs BI Familiarize yourself with manually changing programs so that you can easily modify the programs as your comfort needs change Follow the steps below to change the program times and temperatures NOTE 1 The program time can be set in 10 minute increments 2 The program temperature can be set in increments of 1 F 1 C 3 After 15 seconds without a key press the thermostat will return to normal display mode 4 When setting the program time note the AM PM indicator STEP 1 system MI Slide the System Switch to the HEAT or s heat COOL position to program the correspond cool ing system NOTE If the System Switch is in the OFF position the last position used will be programmed MI Press to enter program mode
7. and Fan come on as expected after installation If the Fan operation is normal leave it in the HG position If the Fan does not come on within a minute of the thermostat calling for heat change the switch position to HE The system selector has no effect in the cooling mode NOTE HG position is for gas and most other systems HE position is for certain electric systems having a fan relay Continued Setting Day and Time Contined STEP 3 BI Press again to change from minute setting to day setting The current day will be flashing day time I Press to change the Day up or down to the current day f STEP 4 W Press again to change back to the normal display day time or hold return NOTE You may press at any time during Day and Time setting to return return to the normal display 12 Hr 24 Hr Time Format Your thermostat is set from the factory in normal 12 AM PM time format To change to 24 hour military time press at any time while the Hour Minute or Day is flashing to toggle between the 12 hour and 24 hour formats The AM PM indicator will not be dis played in 24 hour mode Both the current time and all programs will automatically change to the selected format PROGRAMMING The following time and temperature settings are pre programmed into the thermostat F 20 C Program Number 4 00 pm 68 F 20 C 78 F 26
8. be turned on along with normal opera tion of your system In a normal gas or oil furnace the Fan will be turned on by your furnace after its warm up delay For electric heat air conditioning and heat pump operation the Fan will turn on with the system To run the Fan on continuously slide the Fan switch to the ON position Temporary Manual Override system heat off cool fan auto on To temporarily change the current set temperature without affecting your program A E Press and hold for about 1 second to enter Manual Override mode When display flashes you can release the key I Press again to change to your desired Set Temperature Hold the key for 2 seconds to fast advance the Set Temperature E Press to return to normal mode or wait 5 seconds for it to return automatically E 00 a return E The current program number will flash to signify the Temporary Override MI At the next program change time the Tem porary Override is cancelled and the next program temperature becomes the setpoint temperature To end the Temporary Manual Override program set temperature return Permanent Override SA md ZIDI m D l gt He A y coo temp IN BI Press then press again This will return the set temperature to the current To hold your Manual Override for vacation or just an extended period of time BI Press to make the current program tem perature the HOLD temperature
9. mounting To install your thermostat you should have the following tools and materials Ml Slotted Screwdriver s E Small Philips screwdriver E Hammer Electric drill and 3 16 bit MH Two 1 5 V AA size alkaline batteries Remove Old Thermostat CAUTION Do not remove any wiring from existing thermostat before reading the in structions carefully Wires must be labeled prior to removal BM IMPORTANT Turn off the power to the furnace at the main power panel or at the furnace BI Remove existing thermostat cover and thermostat See Figure 1 Some thermostats will have screws or other locking devices that must first be removed Once the wall mounting plate is exposed look for wires If wires are not visible they may be connected to the back of the wallplate Again look for screws tabs etc Some models have doors that open to expose wires and mounting screws See Figure 1 Typical Home Thermostats Cover Thermostat Cover Wall Mounting Plate Figure 1 Wire Labeling W Each wire coming from the wall to the existing thermostat is connected to a terminal point on that thermostat Each of these terminal points is usually marked with a code letter as shown in Table A below E The number of wires in your system can be as few as two for heat only systems as many as eight or any number in between If you follow the labeling procedures correctly you do not have to be concerned about how many wires there are B
10. 0 F 4 C 3 Compressor Protection This thermostat provides a 3 5 minute delay after shutting off the cooling system before it can be restarted This feature will prevent damage to your compressor caused by rapid cycling It does not prevent a rapid compressor restart due to short power outages 4 Battery Warning Two fresh AA alkaline batteries should provide well over one year of service However when the batteries become drained the Low Battery Indicator will flash on the display When this message occurs install new alkaline batteries You have approximately 1 minute to change the batteries and keep thermostat s clock and program settings Once the batteries have become too low to ensure proper operation your system will be turned Off and the display will be cleared except for flashing Low Battery Indicator on the LCD display CAUTION When only the battery icon flashes on the display the thermostat is shut down and your system will no longer operate In this condition there is no temperature control of your dwelling NOTE If you plan to be away from the premises over 30 days we recommend that you replace the old batteries with new alkaline batteries prior to leaving FEATURES Front Door Covers keys when not used for neat Day Time Key Used for entering the Clock appearance Open by lifting from the bottom setting mode Use with the Up and Down keys to set the time and day LCD Display Shows Time
11. HEAT or MTWTHE COOL will be displayed on the LCD AM MM ee ue y E Ln HEAT NN program EM The Program hour and AM or PM indicator are flashing Press to change the hour u un m m STEP 4 WE Press again to change to the minute posi rogram l l l prog tion The current minute will be flashing I Press to change the minute I Press again to change to the program tem perature The current temperature will be AM flashing E Press to change the temperature H STEP 6 W Press again to move to the next program program number EM Repeat Steps 3 through 5 to change the remaining Weekday and Weekend programs There are a total of 8 programs program E After cycling through all 8 programs press again to return the display to normal BI Press at any time to exit the Program Mode return Reviewing Programs To review your program settings press repeatedly to cycle through the programs You can also make changes at any time ED System Selector Switch The System Selector switch on the front of the thermostat determines the operating mode of the thermostat You may select COOL OFF HEAT NOTE Anytime you install or remove the thermostat from the wallplate slide the System Selector to the OFF position to prevent the possibility of a rapid sys tem On Off Fan Switch The Fan switch should normally be located in the AUTO position The Fan will
12. I There is often no terminal marking on the existing thermostat of two wire heat only systems Just connect either of the wires to the RH terminal then connect the other wire to the W terminal to complete the circuit BI IMPORTANT BEFORE DISCONNECTING ANY WIRES APPLY THE SELF ADHESIVE LABELS PROVIDED TO THE WIRE AS SHOWN IN TABLE A BELOW For example attach the label marked W to the wire that goes to the W or H terminal on your existing thermo Stat IGNORE THE COLOR OF THE WIRES since these do not al ways comply with the standard Continued ED 4 Wiring Diagrams BI Auto Recovery selector DISABLE ENABLE Your thermostat is set from the factory with the Auto Recovery Feature enabled which com 4 wire Heat Cool System plies with the EPA ENERGY STAR Program If you prefer to use normal recovery slide the switch to the DISABLE position Wallplate Jumper Terminals Auto Recovery SW4 Fan Option SW6 Wallplate Terminals Figure 7 F C Selection Fahrenheit Celcius Your thermostat is set for FF mode from the factory To change to C mode follow these steps W Press and hold the Up key Ml Use a paper clip to press the reset key Wallplate Terminals EI Once all the LCD segments turn on release the Up key NOTE To return to F mode press the reset key with a paper clip Do not press any other keys during the reset process All programs and settings will be lost when p
13. nd below the set tempera ture Span 2 This setting has been designed to provide a comfortable room temperature under most all conditions However if you find your system cycling too fast or too slow then the Span can be adjusted to modify the cycle time A M Press and hold BOTH for three seconds The display will flash and SPAN will be y displayed on the LCD A E Press to raise the Span to 3 This setting INCREASES the cycle time by allowing your system to run LONGER y BI Press to lower the Span to 1 This setting DECREASES the cycle time by causing your system to run SHORTER The Span settings remain the same for both HEAT and COOL The Span can be changed at any time and is independent of program times or tem peratures When batteries are installed in the thermostat or the Reset key is pressed the Span is reset back to setting 2 Low Battery Warning Your thermostat has a two stage low battery warning sys tem When the batteries are first detected to be weak the first stage low battery warning is indicated by battery sym bol flashing on the LCD display At your earliest conve nience you need to replace the batteries with 2 new AA alkaline batteries When the batteries become too weak for normal operation the thermostat enters the second stage low battery warning which shuts down the thermostat In this condition BATT flashes alone on the display and the thermostat will turn your system Off
14. ressing RESET Heat Relay or Valve OPERATION Setting Day and Time EM The LCD will show this information when batteries are first installed or after the Reset button is pressed The temperature will update after a few seconds Wallplate Terminals E During time and day setting mode the temperature and program displays will go blank Heat 24V Heat Relay Supply or Valve Ml Example Set the Thermostat to the current time of 2 16 pm on Saturday Refer to the Steps below 3 wire Cool Only System Wallplate STEP 1 ul BI Press to enter time and day setting mode day time Li The current hour and the AM PM indica tor will be flashing Cool 24V Cool Supply Contactor BI Press to change the Hour up or down to the current hour Note the AM PM indicator as the dis play will change at 12 AM and 12 PM X No Connection STEP 2 Selector Switches BI Press again to change from hour setting to na minute setting The current minute will be In order for this thermostat to control your system the system type must be specified by the fackin selector switches on the printed circuit board inside the thermostat 9 E Heating System Selector HG HE switch BI Press to change the Minute up or down to The factory position for this switch is in the HG position Leave it in this position if you have the current minute a gas furnace or an oil burner If you have an electric furnace test to see whether the Heat
15. t will enter Error Mode In this condition the thermostat flashes Err on the LCD display and shuts off your system To correct this problem replace the batteries with 2 new AA alkaline batteries even if you have recently replaced them Next use a paper clip to press the RESET button next to the keypad You will need to reprogram your thermostat and confirm normal operation If Error Mode returns please call Hunter Technical support at 1 888 830 1326 for further infor mation Auto Cut Off Your thermostat will automatically cut off in Heat mode if the room temperature rises above 95 F 35 C It will cut off in Cool mode if the room temperature drops below 40 F 4 C Note that if your system has malfunctioned and no longer responds to thermostat controls the Auto Cut Off will have no effect TROUBLESHOOTING Problem Solution No Display 1 Check battery connections and batteries 2 Press RESET button with a small pin and hold in for two seconds Entire Display Dims 1 Replace Batteries Program Does Not Change 1 Check that the time is set properly to AM at your Desired Setting or PM 2 Check that the thermostat is not in Permanent HOLD mode 3 Check for the correct day setting Auto Fan Does Not Turn 1 Move HG HE selector to correct position On Properly Heating or Cooling Does 1 Check that the function switch is in the correct Not Go On or Off position HEAT or COOL 2 There may be as much as
Download Pdf Manuals