Home
Hunter Fan 42935-0 Fan User Manual
Contents
1. Energy Star Bath Fan Models 82030 82031 amp 82032 READ and SAVE THESE INSTRUCTIONS 42935 01 06 04 2007 z bed aas lt o w D 5 D J3 w HSITDNA m 2 gt z t A WARNING TO REDUCE THE RISK OF ELECTRIC SHOCK OR INJURY OBSERVE THE FOLLOWING 1 Read all instructions before attempting to install or use this appliance This appliance is for general ventilating use only Do not use this appliance for ventilating hazardous or explosive materials Follow the heating equipment manufacturer s guideline and safety standards such as those published by the National Fire Prevention Association NFPA and the American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE and the local code authorities Use this appliance only as described in this manual Any other use not recommended by the manufacturer may cause fire electric shock or injury to persons SAVE THESE INSTRUCTIONS 2 Before installing servicing or cleaning the unit disconnect the power by turning off the circuit breakers to the outlet box and associated wall switch location If you cannot lock the circuit breakers in the off position securely attach a prominent warning device such as a tag to the service panel 3 This unit must be grounded 4 This appliance is not suitable for tub or shower installation and must not be installed within a minimum of 3 feet from the tub or shower opening See Figure A 5 Do n
2. may need to be purchased 11 42935 01 06 04 2007 Go to Section E Final Installation on page 14 Section D Existing Construction accessible from below Remove one of the wiring access slugs on the top of the Remove the mounting rail brackets housing Use a second wiring access plug if needed EXISTING FAN Remove an existing fan and check to make sure the Run the power supply wire through the strain relief leaving opening is large enough to accommodate the new fan 3 between the end of the wire and the strain relief Tighten housing If there is no existing fan choose an appropriate the strain relief around the wire location to make an 11 x 9 5 8 opening 42935 01 06 04 2007 12 Install the wiring and the strain relief into the wiring Connect 4 duct and vent to the outside Use duct tape to access hole you made earlier secure joints If ducting does not fit securely an adapter may need to be purchased Move the housing into the ceiling Position the bottom edge of the housing flush with the sheetrock Go to Section E Final Installation on page 14 Screw mounting screws into joist or framing 13 42935 01 06 04 2007 Section E Final Installation Connect the wiring as shown Install the wiring cover box Make sure all wiring connec tions are inside the wiring cover box NOTE Though this final installation section shows the housing mounted to a joist the final i
3. E IS MADE IN RESPECT OF GLASS FIXTURES OR LIGHT BULBS ORTHE FINISH ON ANY METAL PORTION OF THE BATH EXHAUST FAN THIS WARRANTY IS IN LIEU OF ALL OTHER EXPRESS WARRANTIES THE DURATION OF ANY IMPLIED WARRANTY INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE IN RE SPECT TO ANY HUNTER FAN BATH FAN MOTOR OR OTHER FAN PART IS EXPRESSLY LIMITED TO THE PERIOD OF THE EXPRESS WARRANTY SET FORTH ABOVE FOR SUCH MOTORS OR OTHER PARTS This warranty is voided if your Hunter Bath Fan is not purchased and installed in the U S A This warranty excludes and does not cover defects malfunctions or failures of any Hunter Bath Fan which were caused by repairs by persons not authorized by us use of parts or accessories not authorized by us mishandling improper installation modifications or damage to the Hunter Bath Fan while in your possession or unreasonable use including failure to provide reasonable and necessary maintenance To obtain servicing contact Hunter Fan Company Technical Support at 1 888 830 1326 Please contact us before shipping your Bath Fan to us If we authorize you to ship it to us you will be responsible for all insurance and freight or other trans portation charges to our factory or Service Department We will return your Hunter Bath Fan freight prepaid Your Hunter Bath Fan should be properly packed to avoid damage in transit since we will not be responsible for any such damage Pro
4. akes the following limited warranty to the original user or consumer purchaser of this Hunter Bath Fan If any part of your Hunter Bath Fan fails at any time within one year after the date of sale to you due to a defect in material or workmanship we will repair or at our option replace the defective part free of charge for parts and labor performed at our Service Department in Memphis Tennessee After this one year period you will be responsible for all parts and labor costs for repairs on the Bath Fan except for motor repairs as provided below If your Hunter Bath Fan motor fails at any time within five years after the date of sale to you due to a defect in material or workmanship labor and materials to repair the defect will be provided free of charge at our Service Department in Mem phis Tennessee If no replacement part can be provided we will at our option either refund the actual purchase price of your Bath Fan or provide a replacement free of charge After this five year period you will be responsible for all parts and labor costs for repairs on all parts of the bath exhaust fan IF THE ORIGINAL USER OR CONSUMER PURCHASER CEASES TO OWN THE FAN THIS WARRANTY AND ANY IMPLIED WAR RANTY WHICH THEN REMAINS IN EFFECT INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE ARE VOIDED NO WARRANTY EXPRESS OR IMPLIED INCLUDING ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOS
5. g to joist go to step A1 page 5 For New Construction suspended between joists go to step B1 page 7 For Existing Construction accessible from above go to step C1 page 9 For Existing Construction accessible only from below go to step D1 page 12 5 42935 01 06 04 2007 Section A New Construction attaching to joist Position the correct depth mark at the bottom edge of the joist based upon the the thickness of your sheetrock Run the power supply wire through the strain relief leav Install the wiring and the strain relief into the wiring ing 3 between the end of the wire and the strain relief access hole you made earlier Tighten the strain relief around the wire 42935 01 06 04 2007 6 Go to Section E Final Installation on page 14 Connect 4 duct and vent to the outside Use duct tape to secure joints If ducting does not fit securely an adapter may need to be purchased Slide the mounting rails into brackets Note the orienta Position the correct depth mark at the bottom edge of tion of of the outer ends of the rails the joist based upon the the thickness of your sheetrock 7 42935 01 06 04 2007 Insert mounting screws leaving space between the Attach the rails onto the screws screw head and the joist Screws are supplied Tighten screws Run the power supply wire through the strain relief leav ing 3 between the end of the wire and the strain relief T
6. ighten the strain relief around the wire 42935 01 06 04 2007 8 Install the wiring and the strain relief into the wiring Connect 4 duct and vent to the outside Use duct tape to access hole you made earlier secure joints If ducting does not fit securely an adapter may need to be purchased Go to Section E Final Installation on page 14 Section C Existing Construction accessible from above NO EXISTING FAN Remove an existing fan and check to make sure the opening is large enough to accommodate the new fan housing The opening needs to be 11 x 9 5 8 9 42935 01 06 04 2007 Slide the mounting rails into brackets Using the depth markings on the housing position the bottom edge of the housing so that it will be flush with the sheetrock Mark position of screws by using holes as a template Drill a pilot hole at the TOP of each outline AS SHOWN 42935 01 06 04 2007 10 Insert mounting screws leaving space between the Attach the rails onto the screws screw head and the joist Screws are supplied Tighten screws Run the power supply wire through the strain relief leav ing 3 between the end of the wire and the strain relief Tighten the strain relief around the wire si oe Install the wiring and the strain relief into the wiring Connect 4 duct and vent to the outside Use duct tape to access hole you made earlier secure joints If ducting does not fit securely an adapter
7. it 15 Do not use this appliance with a dimmer switch or a fan speed controller 16 To reduce the risk of fire or electrical shock do not use this fan with any solid state speed control device 17 To prevent a possible fire do not block air intakes or exhaust in any manner 18 If this unit is to be installed over a tub or shower it must be marked as appropriate for the application and be connected to a GFCI Ground Fault Circuit Interrupter protected branch circuit 3 42935 01 06 04 2007 4 1 888 830 1326 for replacement b 97128 01 000 R Housing b 95044 01 000 Mounting Rails Check all the parts If damaged call 97517 01 000 03242 07 133 Wiring Cover D Wiring Cover Screw b 65827 01 000 Strain Relief Bracket gt 74508 53 Strain Relief Bracket Screw g Y x2 D Attachment Screws Q 97118 01 000 97118 03 000 Fan Assembly 97118 05 000 s es 2 74508 03 133 x Fan Mounting Screws b 97934 01 262 Bezel Mounting Screvvs NOTE Strain relief not supplied cable connector must be installed Included Tools Needed Not supplied Estimated assembly time 30 to 60 minutes Before Installation Turn off the povver source Loosen the fan mounting screvvs 42935 01 06 04 2007 4 Loosen the wiring cover screw Remove the wiring cover Choose Installation Option For New Construction attachin
8. nstallation procedure is the same whether the housing is mounted to a joist or suspended between joists Connect fan wiring harness DO NOT ALLOW THE FAN TO Install the fan assembly by inserting the tabs as shown HANG FROM THE WIRING HARNESS and pushing the fan assembly into the housing Make certain the wiring is not pinched between the fan assem bly and the housing Secure the fan assembly by tightening the two fan Install the strain relief bracket mounting screws 42935 01 06 04 2007 14 Install the bezel by inserting the wire clips into the tabs Complete on the inside of the housing Restore power at the source 15 42935 01 06 04 2007 Preventative Maintenance A clean fan provides better service Disconnect the power supply and clean the fan as listed below TO CLEAN THE BEZEL Carefully pull the bezel down Use water a mild detergent such as dishwashing liquid and a soft cloth to clean the bezel DO NOT use abrasive cloths steel wool pads or scouring powders Dry the bezel and reinstall it TO CLEAN THE FAN ASSEMBLY Disconnect power to the unit by switching off the breaker or removing the fuse Turn the wall switch off Remove the bezel as described above Remove the two fan mounting screws Remove the fan from the housing and unplug the fan wiring harness Gently vacuum the fan motor and the housing interior When the fan is clean plug in the fan wiring harne
9. of of purchase is required when requesting warranty service The purchaser must present the sales receipt or other document that establishes proof of purchase IN NO EVENT SHALL HUNTER FAN COMPANY BE LIABLE FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES SOME STATES DO NOT ALLOW LIMITATIONS ON HOW LONG AN IMPLIED WARRANTY LASTS OR THE EXCLUSION OR LIMITA TION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES SO THE ABOVE LIMITATION OR EXCLUSIONS MAY NOT APPLY TO YOU THE WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS AND YOU MAY ALSO HAVE OTHER RIGHTS WHICH VARY FROM STATE TO STATE Hunter Fan Company 2500 Frisco Avenue SINCE 182 Memphis Tennessee 38114 Printed in China 17 42935 01 06 04 2007 42935 01 06 04 2007 18
10. ot install this appliance lower than 7 feet 2 13 m above the floor in the ceiling See Figure A oe se Bath Fan NOTE This illustration is not to scale L 7 ft min 7 2 13 m Tub or Shovver area DURA Continued 42935 01 06 04 2007 2 6 Never place a switch where it can be reached from a tub or shower Do not install this appliance in a tub or shower enclosure 7 Installation work and electrical wiring must be done by qualified person s in accordance with all applicable codes and standards including fire rated construction codes and standards 8 When cutting or drilling into wall s or ceiling do not damage electrical wiring or other hidden utilities 9 Do not install this product in a wall This product is designed for installation in ceilings up to a 12 12 pitch 45 degrees Ductwork must point upward 10 Ducted fans must always be vented to the outdoors Keep ducting as short and as straight as pos sible 11 Extreme caution is necessary when any is used by or near children or invalids and when ever the is left operating and unattended 12 To avoid motor bearing damage and noisy unbalanced blower wheel keep drywall spray construction dust etc off power unit 13 Read specification label on product for further information and requirements 14 Do not insert or allow foreign objects to enter any ventilation or exhaust opening as this may cause an electric shock or fire or damage the un
11. ss Reinstall the fan and tighten the two fan mounting screws Reinstall the bezel Restore power to the appliance Test the appliance If the fan does not run 1 check the power source or 2 dis connect power to the appliance disassemble as described above check the fan assembly plug restore power and test the unit If the fan still does not run contact a qualified installer NEVER IMMERSE METAL OR ELECTRICAL COMPONENTS IN WATER Maintenance The fan motor is permanently lubricated and never needs olling If the motor bearings are making excessive or unusual noises contact Hunter Technical Support see Troubleshooting section to order a new fan assembly Trouble Shooting Problem Fan does not come on Solution e Turn power on replace fuse or reset breaker e Hunter Fan Bath Ventilators are extremely quiet To confirm that the fan is running place your hand near the vents to feel the air movement e Check all plug connections to be sure they are secure e Check the wiring to make sure it matches the wiring diagram Problem Fan is noisy Solution e Check and tighten all fasteners e Check the bezel to make sure it is secure e Check the flapper to make sure it moves freely 42935 01 06 04 2007 16 Trouble Shooting cont If you need parts or service assistance please call 888 830 1326 or visit us at our website at http www hunterfan com Hunter Fan Company Bath Fan LIMITED WARRANTY Hunter Fan Company m
Download Pdf Manuals
Related Search
Related Contents
Objectif - Diocèse d`Annecy Engineering 4862 MICROPROCESSORS 協調自律学習による授業デザインと実践 Zephyr ALL-E42ABX Ventilation Hood User Manual Copyright © All rights reserved.
Failed to retrieve file