Home

Hunter Fan 42834-01 Fan User Manual

image

Contents

1. Wire Connector wo A 42834 01 01 27 10 Hunter Fan Company 7 6 Installing the Motor Housing 6 1 Place the fan housing over the motor Step 6 1 6 2 Align the keyholes in the fan housing with the two partially installed canopy screws in the hanger bracket Rotate the fan housing to situate the screws in the narrow ends of the keyholes 6 3 Install the two remaining canopy screws into the holes in the fan housing and into the hanger bracket Securely tighten all screws 6 4 Install the rubber plugs into the holes over the canopy screws 9 42834 01 01 27 10 Hunter Fan Company 7 Assembling the Blades Hunter fans use several styles of fan blade irons brackets that hold the blade to the fan 7 1 Install the grommets into the blades by hand Step 7 1 Detail 7 2 Place each blade between a blade iron and medallion Install three blade screws to attach the medallion to the blade iron Repeat for all blades 7 3 For each blade insert one blade mounting screw through the blade iron and attach lightly to the fan Insert the second blade mounting screw then securely tighten both mounting screws Blade Assembly Use with grommet screws Use without grommet Blade Mounting Screw 10 42834 01 01 27 10 Hunter Fan Company Steps 7 2 7 3 8
2. Thread the lead wires from the outlet box down through the hole in the middle of the hanger bracket Align the slotted holes in the hanger bracket with the pilot holes you drilled in the wood support structure Note The isolators should be flush against the ceiling Place a flat washer on each of the two 3 wood screws and pass the screws through the slotted holes in the hanger bracket into the pilot holes you drilled Tighten the screws into the 9 64 pilot holes do not use lubricants on the screws Do not over tighten Flat Washer EEE nn 5 42834 01 01 27 10 Hunter Fan Company 3 Wood Screw Hanger n E a A Canopy Screw Isolator Step 2 2 Canopy Screw X _ me Steps 2 4 2 6 3 Assembling and Hanging the Fan 3 1 Position the square hanger so that the green ground wire attached to the square faces out of the large opening in the metal bracket 3 2 Holding the wires out of the way lift the motor assembly and place the square hanger into the opening in the ceiling plate A WARNING Make sure the square hanger can not rotate in the metal bracket Failure to do so could result in the fan falling 3 3 Install two locking screws through the holes in the side of the metal bracket to secure the square hanger Motor Assembly Green Ground Wire Step 3 2 Green Ground Wire L
3. odels Owner s Guide and Installation Manual For reference also attach your receipt or a copy of your receipt to the manual For Your Records and P Warranty Assistance e 2 A INg fmia BWR TI zR 0 gt ra Q 74 SINCE 1886 a Form 42834 01 20100127 2010 Hunter Fan Co Welcome Your new Hunter ceiling fan is an addition to your home or office that will provide comfort and performance for many years This installation and operation manual gives you complete instructions for installing and operating your fan We are proud of our work We appreciate the opportunity to supply you with the best ceiling fan available anywhere in the world Before installing your fan for your records and warranty assistance record information from the carton and Hunter nameplate label located on the top of the fan motor housing Cautions and Warnings e READ THIS ENTIRE MANUAL CAREFULLY BEFORE BEGINNING Table of Contents INSTALLATION SAVE THESE INSTRUCTIONS e Use only Hunter replacement parts e To reduce the risk of personal injury attach the fan directly to the 2 Installing the Hanger Bracket support structure of the building according to these instructions 3 e Assembling the Fan and use only the hardware supplied To avoid possible electrical shock before installing your fan disconnect the power by turning off the circuit breakers to the outlet box and associated wall s
4. dealer or call Hunter Technical Support Department at 866 268 1936 Preparing the Fan Site Before you begin installing the fan follow all the instructions in the pullout sheet called Preparing the Fan Site Proper ceiling fan location and attachment to the building structure are essential for safety reliable operation maximum efficiency and energy savings 4 Installing Multiple Fans If you are installing more than one fan keep the fan blades and blade irons if applicable in sets as they were shipped 42834 01 01 27 10 Hunter Fan Company K2 2 Installing the Hanger Bracket A CAUTION To avoid possible electrical shock before installing your fan disconnect the power by turning off the circuit breakers to the outlet box and associated wall switch location If you cannot lock the circuit breakers in the off position securely fasten a prominent warning device such as a tag to the service panel 2 1 2 2 2 5 2 6 Drill two pilot holes into the wood support structure through the outermost holes in the outlet box The pilot holes should be 9 64 in diameter Partially install two canopy screws in the holes on each end of the hanger bracket as shown in the figure to the right Your fan comes with four mounting isolators Position the isolators between the hanger bracket and ceiling by inserting the raised areas on each isolator into the holes in the hanger bracket
5. Completing Your Installation With a Bowl Light Fixture Your Hunter fan comes with an integrated light fixture assembly A WARNING Use only the light fixture supplied with this fan model 8 1 To attach the upper switch housing partially install two housing assembly screws into the switch housing mounting plate 8 2 Feed the upper plug connector through the center opening of the housing 8 3 Align the keyhole slots in the housing with the housing assembly screws 8 4 Turn the housing counterclockwise until the housing assembly screws are firmly situated in the narrow end of the keyhole slots Install the remaining screw into the housing Tighten all three screws firmly Steps 8 1 8 3 Housing er A CAUTION Make sure the upper switch housing is securely feral ey nig attached to the switch housing mounting plate Failure to properly Housing attach and tighten all three assembly screws could result in the switch housing and light fixture falling 8 5 If you want to install the light fixture proceed with step 8 6 now If you do not want to install the light fixture you need to uninstall it now See Uninstalling the Light Fixture on step 8 15 Once you have uninstalled the light fixture continue with step 8 6 lI 42834 01 01 27 10 Hunter Fan Company 8 e Completing Your Installation With a Bowl Light Fixture Continued 8 6 To attach the lower switch housing connect
6. the upper plug connector from the motor to the lower plug connector in the lower switch housing assembly Note Both plug connectors are polarized and will only fit together one way Make sure the connectors are properly aligned before connecting them Incorrect connection could cause improper operation and damage to the product lt Plug Connector 8 7 Place the lower switch housing assembly over the upper switch housing Align the side screw holes in the upper and lower switch housings Attach the lower switch housing to the upper switch housing with three housing assembly screws Steps 8 6 8 7 Lower Switch Housing os eae Plug TT Note In compliance with Canadian energy regulations this ceiling Connector fan contains a device that restricts the light output to a Detail maximum of 190 Watts Exceeding that limit or the marked limit on this product may result in fire hazard or improper operation Housing O Assembly Screw 12 42834 01 01 27 10 Hunter Fan Company K2 8 e Completing Your Installation With a Bowl Light Fixture Continued Installing the Glass Bowl 8 8 First install B10 candelabra bulbs 60 Watt Maximum into the sockets Thread the light and fan pull chains through the hole in the center of the glass bowl Then thread the light pull chain through the hole in the center of the cover plate Thread the fan pull chain through the grommet hole i
7. Problem Excessive wobbling 1 If your fan wobbles when operating use the enclosed balancing kit and instructions to balance the fan 2 Tighten all blade iron screws 3 Turn power off support fan very carefully and check that the hanger ball is properly seated Problem Lights turn off when installed or dim when turned on 1 Check to make sure the wattage and type of light bulbs installed match the specifications on the light socket Problem Lights shut off suddenly 1 Turn the power to the fan off at the wall switch Wait 30 seconds then resume power to the fan If you need parts or service assistance please call 888 830 1326 In Canada call 866 268 1936 or visit us at our Web site at http www hunterfan com Hunter Fan Company 7130 Goodlett Farms Parkway 400 Memphis Tennessee 38016 16 42834 01 01 27 10 Hunter Fan Company
8. all mounted or remote speed control To install and use the accessories follow the instructions included with each product For quiet and optimum performance of your Hunter fan use only Hunter speed controls Low Profile Mounting fits close to the ceiling recommended for ceilings less A CAUTION To reduce the risk of than 8 feet high personal injury attach the fan directly to the support structure of the building according to these instructions and use only the hardware supplied 3 42834 01 01 27 10 Hunter Fan Company K2 l Getting Ready To install a ceiling fan be sure you can do the following e Locate the ceiling joist or other suitable support in ceiling e Drill holes for and install wood screws e Identify and connect electrical wires e Lift 40 pounds If you need help installing the fan your Hunter fan dealer can direct you to a licensed installer or electrician Gathering the Tools You will need the following tools for installing the fan e Electric drill with 9 64 bit e Standard screwdriver magnetic tip recommended e Phillips head screwdriver magnetic tip recommended e Wrench or pliers e Ladder height dependent upon installation site Checking Your Fan Parts Carefully unpack your fan to avoid damage to the fan parts Refer to the included Parts Guide Check for any shipping damage to the motor or fan blades If any parts are missing or damaged contact your Hunter
9. g A vacuum cleaner brush nozzle can remove heavier dust Remove surface smudges or accumulated dirt and dust using a mild detergent and a slightly dampened cloth You may use an artistic agent but never abrasive cleaning agents as they will damage the finish Clean wood finish blades with a furniture polishing cloth Occasionally apply a light coat of furniture polish for added protection and beauty Clean painted and high gloss blades in the same manner as the fan finish To Change Airflow Direction Turn the fan off and let it come to a complete stop Slide the reversing switch on the fan to the opposite position Restart fan 42834 01 01 27 10 Hunter Fan Company a J Reversing Switch In warm weather use downward air flow pattern In cold weather use upward air flow pattern 10 Troubleshooting Problem Nothing happens fan does not move 1 Turn power on replace fuse or reset breaker 2 Loosen canopy check all connections according to the wiring the fan section 3 Check the plug connection in the switch housing 4 Push motor reversing switch firmly left or right to ensure that the switch is engaged 5 Pull the pull chain to ensure it is on 6 Remove the shipping bumpers Problem Noisy operation 1 Tighten the blade assembly screws and blade iron armature screws until snug 2 Check to see if the blade is cracked If so replace all the blades
10. hole Install the dummy terminals included in the sack parts on the two disconnected wires in the lower switch housing Install the switch housing cap and plug button to the lower switch housing Once you have uninstalled the light fixture continue with step 7 6 Male Dummy Terminal Cap Female Dummy Terminal Plug Button 14 j A Lower Switch Housing b T Steps 8 16 8 18 Threaded Rod TE Step 8 20 gt 42834 01 01 27 10 Hunter Fan Company 9 1 9 Operating and Cleaning Your Ceiling Fan Turn on electrical power to the fan 9 2 The fan pull chain controls power to the fan The pull chain has four settings in sequence High Medium Low and Off Fa 9 4 9 5 e Pull the chain slowly to change settings e Release slowly to prevent the chain from recoiling into the blades e The chain uses a breakaway connector that separates if the chain is jerked If this happens simply reinsert the chain into the connector Ceiling fans work best by blowing air downward counterclockwise blade rotation in warm weather to cool the room with a direct breeze In winter having the fan draw air upward clockwise blade rotation will distribute the warmer air trapped at the ceiling around the room without causing a draft For cleaning finishes use a soft brush or lint free cloth to prevent scratchin
11. itches are not included Select an acceptable general use switch in accordance with national and local electrical codes 5 1 5 2 JPA 5 4 5 5 5 6 5 7 Before attempting installation make sure the power is still off To connect the wires hold the bare metal leads together and place a wire nut over them then twist clockwise until tight For all these connections use the wire nuts provided Connect the bare or green ground wire grounded from the ceiling to the green ground wire grounded from the ceiling plate and the green ground wire from the fan Connect the white wire ungrounded from the ceiling to the white wire ungrounded from the fan Connect the remaining wires as follows Dual Switch Wiring e The black wire ungrounded from the ceiling to the black wire ungrounded from the fan e The black white wire ungrounded from the fan to the wire ungrounded for the wall switch Single Switch Wiring e The black wire ungrounded from the ceiling to the black ungrounded and the black white wire ungrounded from the fan A CAUTION Be sure no bare wire or wire strands are visible after making connections Turn the splices upward and push them carefully back through the ceiling plate into the outlet box Spread the wires apart with the grounded wires on one side of the outlet box and the ungrounded wires on the other side of the outlet box 8 x Q
12. n the side of the cover plate Place the cover plate up against the glass bowl Align the holes in the cover plate and glass bowl Thread the light pull chain through the finial and screw the finial onto the threaded rod end until tight 8 13 Attach the extra pull chains included to the light and fan pull chains using the plastic breakaway connector Cron may find the E Light Bulbs plastic breakaway connector on the g i B10 Candelabra Base 60 Watt Maximum kt _ Metal Rod 3 a Metal Disk end of the extra chain Glass Bowl a Cover Plate Breakaway wy Finial Connector Le 13 42834 01 01 27 10 Hunter Fan Company 8 Completing Your Installation With or Without a Bowl Light Fixture Continued Uninstalling the Light Fixture 8 14 To uninstall the light fixture first disconnect the plug connectors between the black wire and the black white wire Disconnect the plug connectors between the two white wires Uninstall the nut and washer from the end of the light fixture inside the lower switch housing Unscrew the threaded rod of the light fixture from the lower switch housing Remove the light fixture from the lower switch housing pulling disconnected wires through the hole in the center of the lower switch housing Note When removing the wires pull the thin plug connector male through first and then pull the other plug connector female through the
13. ocking Screw 6 42834 01 01 27 10 Hunter Fan Company 4 Securing Fan to Secondary Support System 4 1 Find the looped end of the braided cable and insert it through the ceiling plate and one of the holes in the outlet box into the ceiling 4 2 Access the support brace in the ceiling You may not be able to do this from below the ceiling depending on your installation site 4 3 Drive a 10 x 38mm 1 1 2 wood screw and washer into the side of the brace that holds the outlet box Leave 3mm 1 8 of space between the support brace and the washer 4 4 Wrap the braided cable around the support brace once creating a complete circle 4 5 Hook the looped end of the cable over the wood screw so that the braided cable lies between the washer and the support brace 4 6 Tighten the loop and secure the screw and washer all the way down to the support brace 4 7 Coil up the excess cable 4 8 Return to the fan so you can complete the fan wiring Steps 4 2 4 3 3mm 18 Support Brace Outlet Box Ceiling Steps 4 4 4 5 oe E ue Steps 4 6 4 7 I oY x 7 42834 01 01 27 10 Hunter Fan Company a J 5 Wiring the Fan All wiring must be in accordance with national and local electrical codes and ANSI NFPA 70 If you are unfamiliar with wiring use a qualified electrician Wall sw
14. witch location If you cannot lock 5 e Wiring the Fan the circuit breakers in the off position securely fasten a prominent 6 Installing the Motor Housing warning device such as a tag to the service panel All wiring must be in accordance with national and local electrical codes and ANSI NFPA 70 If you are unfamiliar with wiring use a qualified electrician To reduce the risk of personal injury do not bend the blade 9 Operating and Cleaning attachment system when installing balancing or cleaning the fan Your Ceiling Fan Never insert foreign objects between rotating fan blades To reduce the risk of fire electrical shock or motor damage do not use a Solid state speed control with this fan Use only Hunter speed controls 1 e Getting Ready 4 Securing Fan to Secondary Support System 7 Assembling the Blades 8 Completing Your Installation With a Light Fixture 10 Troubleshooting 2010 Hunter Fan Company 2 42834 01 01 27 10 Hunter Fan Company Mounting and Optional Accessories BERT Understanding Mounting Hunter s patented mounting system provides you maximum ease in installing your fan This fan was designed to be mounted only on flat ceilings and can be used on ceilings less than 8 feet high Low Profile _ Ceiling Considering Optional Accessories ounting Outlet Box i OPE Style Consider using Hunter s optional accessories including a w

Download Pdf Manuals

image

Related Search

Related Contents

取扱説明書 (1.8MB) - 日本ゼネラル・アプラィアンス  LIBRATONE ZIPP OWNER`S MANUAL  DE - Rasor 1946  Nonin Medical Onyx II 9560  User Manual  Bedienungsanleitung  Medical data recording system  Communicateur HLD- 323 Mode d`emploi FRANÇAIS - Migros  用途 適用機種 安全上のご注意 梱包部品    

Copyright © All rights reserved.