Home

Hunter Fan 42798-01 Fan User Manual

image

Contents

1. Table of Contents 1 e Getting Ready 2 Installing the Ceiling Mounting Plate 3 e Assembling and Hanging the Fan 4 Setting the Remote Transmitter and Receiver 5 e Wiring the Fan 6 Installing the Ceiling Plate Cover 7 Assembling the Blades 8 Activating Auto Balance 9 e Completing Your Installation With or Without a Bowl Light Fixture 10 e Operation amp Maintenance 42798 01 09 16 09 Hunter Fan Company l Getting Ready Congratulations Your new Hunter ceiling fan is an addition to your home or office that will provide comfort and reliable performance for many years We are proud to supply you with the best ceiling fan available anywhere in the world Before Installation Before installing your fan be sure you can do the following e Locate the ceiling joist or other suitable support in the ceiling e Drill holes and install wood screws or expansion anchors e If you have a concrete ceiling you will need M5 x 30 mm expansion anchors and screws Sold separately e Identify and connect electrical wires Lift 16 kg 40 lbs Levantar 16 Kg 40 Ib How to Use This Manual Be sure to read the entire manual before beginning installation and save any extra parts for future use This manual will help you install operate and maintain your new fan These instructions are designed to make installation and assembly as simple and efficient as possible Each step has four component
2. connector 70 over them then twist clockwise until tight For all these from the ceiling to the green ground wire grounding from the ceiling connections use the wire connectors provided mounting plate and the green ground wire from the pipe ball assembly 7 I 42798 01 09 16 09 Hunter Fan Company 5 Wiring the Fan Using the large wire connectors 70 connect the white wire and the black Using the small wire connectors 70 connect the wires from the fan as follows wire from the ceiling as follows _ es ARO e The black wire with a white stripe from the fan to the red wire from the receiver e The white common power wire from the ceiling to the white wire from marked on white tag LIGHT OUT the receiver marked on red tag NEUTRAL IN a i e The black wire from the fan to the black wire from the receiver marked on e The black power wire from the ceiling to the black wire from the receiver white tag FAN OUT marked on red tag LIVE IN WARNING Be sure no bare wire or wire strands are visible after making connections Using the small wire connectors 70 connect the wire from the fan as follows Push all wires and wire connectors 70 except for the white antenna wire e The white wire from the fan to the white wire from the receiver marked on from the receiver 86 back through the ceiling mounting plate 2 into the white tag COMMON OUT outlet box Position the rec
3. from any hardware store or electrical supply house 4 2 Orient the outlet box so that both the inner and outer holes in the box align with the joist or support brace 4 3 Drill pilot holes no larger than the minor diameter of the wood screws 5 64 through the inner holes of the outlet box 4 4 Attach the outlet box directly to the support brace or joist with two 8 x 1 1 2 wood screws and washers Th e bottom of the outlet box must be recessed a minimum of 1 16 into the ceiling Step 5 Prepare the Wiring 5 1 Make sure the circuit breakers to the fan supply line leads and associated wall switch location are turned off If you cannot lock the circuit breakers in the off position securely fasten a prominent warning device such as a tag to the service panel 5 2 Thread the fan supply line through the outlet box so that the fan supply line extends at least 6 beyond the box 5 3 Attach the fan supply line to the outlet box with an approved connector available at any hardware store or electrical supply house 5 4 Make certain the wiring meets all national and local standards and ANSI NFPA 70 You have now successfully prepared your ceiling fan site For instructions to install your ceiling fan go to your fan manual and continue with Section 2 Installing the Ceiling Plate A CAUTION All wiring must be in accordance with national and local electrical codes and ANSI NFPA 70 If you are unfamiliar
4. 9 e Hunter Fan Company e cont a Removing the Light Fixture Removing the Light Fixture Remove the nut and washer from inside the center of the lower switch Unscrew the light bulb socket housing Removing the Light Fixture Removing the Light Fixture Pull the large male plug connector through the hole in the center of the Remove the light fixture bracket by removing the 2 screws attaching the lower switch housing Then pull out the small female connector bracket to the lower switch housing 19 42798 01 09 16 09 Hunter Fan Company Removing the Light Fixture Install the switch housing cap and plug button to the lower switch After your installation is complete restore power to the fan Wash your hands after installing the fan housing You can mount the remote holder to any toggle switch plate with the screws already in the switch plate Or you can simply mount the remote holder on the wall 20 42798 01 09 16 09 Hunter Fan Company 10 Operation amp Maintenance Cleaning and Maintenance Airflow Direction Ceiling fans work best by blowing air downward Caring for finishes counterclockwise blade rotation in warm weather to cool the For cleaning finishes use a soft brush or lint free cloth to prevent room with a direct breeze In winter having the fan draw air scratching A vacuum cleaner brush nozzle can remove heavier upward clockwise blade rotation wil
5. ING for an extended Use only the i period of time P To remove the one battery remove p en the back cover of PPIE eens this fan the remote control transmitter Remove used batteries promptly Install the included 12 Volt type GP23A battery 199 into the transmitter The remote control device complies with part 15 of the FCC rules Changes or 87 Clean the battery contacts and also those of the device prior to modifications not expressly approved by Hunter Fan Company could void your battery installation Ensure the battery is installed correctly with regard authority to operate this equipment Operation is subject to the following two to polarity and Please contact your local battery recycling center for conditions 1 This device may not cause harmful interference 2 This device proper battery disposal information must accept any interference received including interference that may cause undesired operation 10 42798 01 09 16 09 Hunter Fan Company 5 Wiring the Fan WARNING All wiring must be in accordance with national and local electrical codes and ANSI NFPA 70 If you are unfamiliar with wiring use a qualified electrician Wall switches are not included Select an acceptable general use switch in accordance with national and local electrical codes To connect the wires hold the bare metal leads together and place a wire Using a large wire connector 70 connect the ground wire grounding
6. d wires extend from outlet box If your existing fan site is suitable skip ahead to Section 2 Installing the Ceiling Plate 3 e 30 From Wall or Nearest _ 8 Minimum Ceiling Height Obstruction 7 Minimum Blades to Floor Fan Support System Fan Support System Suitable Existing Fan Site Outlet Box 42798 01 09 16 09 e Hunter Fan Company 1 Getting Ready continued Step 2 Cut the Ceiling Hole 2 1 Locate the site for the ceiling hole directly below the joist or support brace that will hold the outlet box and fan 2 2 Cut a 4 diameter hole through the drywall or plaster of the ceiling You will use the hole to install the support brace and outlet box Step 3 Install a Support Brace If Necessary Determine if there is a ceiling joist directly above the ceiling hole If the joist is there determine if it is positioned to allow you to recess the outlet box a minimum of 1 16 into the ceiling If NOT install a support brace as follows 3 1 Attach a 2 x 4 support brace between two joists Position it to allow you to recess the bottom of the outlet box a minimum of 1 16 into the ceiling 3 2 Check the support brace to ensure it will support the full weight of the fan and light kit Step 4 Install the Outlet Box 4 1 Obtain a UL approved octagonal 4 x 1 1 2 outlet box plus two 8 x 1 1 2 wood screws and washers available
7. ectors are p polarized and will only fit together one way lt gt Make sure the connectors are properly aligned before connecting them Incorrect connection could cause improper operation and damage to the product Connect the upper plug connector from the fan body to the lower plug Place the lower switch housing assembly 31 over the upper switch connector in the lower switch housing assembly 31 housing 30 Align the side screw holes in the upper and lower switch housings Attach the lower switch housing to the upper switch housing with three outer switch housing screws 131 Install the included Pin Based CFL bulb 259 26 Watt Maximum into the Install the included Pin Based CFL bulb 259 26 Watt Maximum into the socket socket 17 42798 01 09 16 09 e Hunter Fan Company 9 Completing Your Installation With or Without a Bowl Light Fixture cont E F Lift the glass bowl 150 up so the threaded finial rod fits through the hole Place the cover plate 148 up against the glass bowl 150 Align the holes in the glass bottom in the cover plate 148 with the grommet hole of the metal disc Removing the Light Fixture Screw the finial 149 onto the threaded finial rod end until tight Disconnect the plug connectors between the black wire and the black wire with a white stripe Disconnect the plug connectors between the two white wires 18 42798 01 09 16 0
8. eiver 86 in the ceiling mounting plate cover so that the antenna is close to the edge for clear reception 12 42798 01 09 16 09 Hunter Fan Company P Ieo N Rotate the pipe ball assembly 7 so the tab in the ceiling mounting plate cover 3 is secure in the hanger ball groove Note Your fan may have multiple tabs and grooves that must be aligned o Swing the fan up to align the ceiling mounting plate cover screw holes with the mounting holes on the ceiling mounting plate 2 Partially install a ceiling mounting plate cover screw 62 between the slots in the ceiling mounting plate cover 3 When all the holes are properly the holes opposite the ceiling mounting plate tabs aligned securely tighten all three ceiling mounting plate cover screws Verify that the tabs in the ceiling mounting plate cover are still in the grooves of the hanger ball Holding the ceiling mounting plate cover 3 up with the screw holes aligned partially install two ceiling mounting plate cover screws 62 into 13 42798 01 09 16 09 e Hunter Fan Company 6 Installing the Ceiling Plate Cover continued g N oo AS Align the tabs on the trim ring opposite the grooves in the hanger ball Should you need to remove the trim ring press firmly on opposite sides of Using both hands push the ceiling mounting plate cover trim ring 4 up the trim ring 4 directly above the groove in the hanger ba
9. er 3 with the hooks on the ceiling mounting plate 2 Note To hang the fan you must tilt the ceiling mounting plate cover 3 to an almost vertical position so that the ceiling mounting plate cover 3 slots sit on the ceiling mounting plate hooks 7 09 16 09 Hunter Fan Company 3 Assembling and Hanging the Fan continued J F Place the slots over the hooks to hang the fan Pipe Ball Optional Pipe Ball Instructions Remove the pipe ball screw from the standard pipe ball assembly then slide the ball off the pipe 8 42798 01 09 16 09 e Hunter Fan Company gt Optional Pipe Ball Instructions Your Hunter fan comes with an optional pipe ball assembly extension pipe If you would like to use the enclosed optional 6 inch pipe ball assembly follow Steps 3 6 3 9 Note The Auto Balance system is designed for pipe ball assemblies that are 6 and shorter If you use a pipe ball assembly longer than 6 inches do not activate the Auto Balance Optional Pipe Ball Instructions Remove the pin from the pipe then slide the wedge off the pipe 3 Assembling and Hanging the Fan continued Optional Pipe Ball Instructions Optional Pipe Ball Instructions Remove the screw and ground wire from the pipe Reassemble the ground wire wedge pin ball and pipe ball screw in that order onto the long pipe ball assembly Go back to Step 3 2 4 Setting the Re
10. gs Choose a fan site where No object can come in contact with the rotating fan blades during normal operation The fan blades are at least 7 feet above the floor and the ceiling is at least 8 feet high The fan blades have no obstructions to airflow such as walls or posts within 30 inches of the fan blade tips The fan is directly below a joist or support brace that will hold the outlet box and the full weight of the fan Checklist for Existing Fan Site If you want to use an existing fan site complete the following checklist to determine if the site is acceptable and safe for your new Hunter fan If you cannot check off every item prepare a new fan site as described on this page Fan Support System Fan attaches directly to building structure Fan support system will hold full weight of the fan and light kit Ceiling Hole The outlet box clearance hole is directly below the joist or support brace Outlet Box The outlet box is an UL approved octagonal 4 x 1 1 2 outlet box or as specified by the support brace manufacturer e The outlet box is secured to the joist or support brace by wood screws and washers through the inner holes of outlet box The outer holes of the outlet box are aligned with joist or support brace The bottom of the outlet box is recessed a minimum of 1 16 into ceiling Wiring The electrical cable is secured to outlet box by an approved connector Six inches of lea
11. l distribute the warmer air dust Remove surface smudges or accumulated dirt and dust trapped at the ceiling around the room without causing a draft using a mild detergent and a slightly dampened cloth You may use an artistic agent but never abrasive cleaning agents as they will damage the finish Caring for blades Note Be careful to not bend the blades when cleaning Clean wood finish blades with a furniture polishing cloth Occasionally apply a light coat of furniture polish for added protection and beauty Clean painted and high gloss blades in the same manner as the fan finish If you need parts or service assistance please call 888 830 1326 or visit us at our Web site at http www hunterfan com Hunter Fan Company 7130 Goodlett Farms Parkway 400 Winter Memphis Tennessee 38016 Upward Airflow Down rd Arow Clockwise Counterclockwise 21 42798 01 09 16 09 Hunter Fan Company 10 Operation amp Maintenance Operation Troubleshooting The fan pull chain controls power to the fan Problem Nothing happens fan does not move e The pull chain has four settings in sequence High Medium e Turn power on replace fuse or reset breaker Low and Off e Loosen canopy check all connections according to the wiring e Pull the chain slowly to change settings the fan section e Release slowly to prevent the chain from recoiling into the Check the plug connection in the switch housing blades Pu
12. ll The tabs will to the top of the ceiling mounting plate cover The ceiling mounting plate flex out releasing the ceiling mounting plate cover trim ring 4 cover trim ring will snap and lock into place 7 Assembling the Blades Squeeze the rubber blade grommets 66 into the holes in the blades 46 Attach each blade 46 to a blade arm 98 using three blade assembly screws 67 The blades may appear slightly loose after screws are tightened This is normal 14 42798 01 09 16 09 Hunter Fan Company Loosen DO NOT REMOVE the blade to arm screws 47 that are holding Slide the blade arms 98 onto the blade to arm screws 47 Tighten the the ae bumpers in place Push the shipping bumpers in then lift blade to arm screws 47 as tight as possible with a screwdriver them off 8 Activating Auto Balance Note After the retaining screws are removed the blades will feel loose This is normal as loose blades are a characteristic of the Auto Balance __ system If you are using one of the enclosed pipe ball assemblies it is now time If you are using a pipe ball assembly longer than 6 inches leave the for you to activate the Auto Balance system by removing the five red retaining screws in their place and continue the installation process retaining screws Rotate the blades slowly until one of the red retaining screws is visible through the notch in the mounting plate Remove the
13. mote Transmitter and Receiver When two or more fans are located near each other you may want to have the receiver transmitter for each fan set to a diff erent code so that the operation of one fan does not affect the operation of the other fans 4 1 The DIP switches for the receiver 86 are located on the flat surface of the receiver The DIP switches for the transmitter 87 are in the battery compartment IMPORTANT Before you change the DIP switch settings make sure the battery is not connected to the transmitter 9 42798 01 09 16 09 e Hunter Fan Company gt a 4 Setting the Remote Transmitter and Receiver cont Receiver 1 Receiver 2 DIP Switches DIP Switches Set to 0111 Set to 0100 Transmitter 1 Transmitter 2 DIP Switches DIP Switches Set to 0111 Set to 0100 Change the position of the DIP switches in the remote transmitter 87 and There is a toggle switch beside the DIP switches on the transmitter 87 the receiver 86 Make sure that the DIP switches match in the remote Move the toggle switch toward the side that reads CFL if you are going to receiver 86 and transmitter 87 If they don t match the transmitter will operate the fan with the included CFL bulbs Move the switch to the INC not function side if you are going to use incandescent bulbs Note Remove the battery from the remote control transmitter if the product is to remain unused A WARN
14. o the 9 64 pilot holes do not use lubricants on the screws Do not over tighten Toward elle Unbundle the wires from the fan Note Your Hunter fan comes with an optional pipe ball assembly extension pipe If you are hanging the fan on a ceiling higher than 10 feet tall and you would like to use the enclosed optional pipe ball assembly follow Steps 3 5 3 9 For Angled Ceilings Be sure to orient the ceiling mounting plate 2 so that the two tabs are pointing toward the ceiling peak 6 42798 01 09 16 09 e Hunter Fan Company 3 Assembling and Hanging the Fan A CAUTION The motor cover adapter has a special coating on the threads Do not remove this coating the coating prevents the pipe ball assembly from unscrewing Once assembled do not remove the pipe ball assembly Insert the pipe ball assembly 7 through the ceiling mounting plate cover Using the provided Allen wrench 79 loosen the setscrew 8 on the 3 and ceiling mounting plate cover trim ring 4 Feed the wires from the motor cover adapter to install the pipe and ball assembly 7 When the pipe and ball assembly 7 is fully installed 2 3 threads on the pipe will still be visible this is normal fan through the pipe ball assembly 7 Use the Allen wrench 79 to securely retighten the setscrew 8 42798 01 Raise the fan and align the slots in the ceiling mounting plate cov
15. retaining screw from the bottom of the fan housing using a screwdriver Repeat this process for all 5 retaining screws 15 J 42798 01 09 16 09 Hunter Fan Company 9 Completing Your Installation With or Without a Bowl Light Fixture a C Partially install inner switch housing screws 69 into the switch housing Feed the upper plug connector through the center opening of the upper mounting plate switch housing 30 Align the keyhole slots in the upper switch housing with the inner switch Your Hunter fan comes with an integrated light fixture assembly and an optional housing screws 69 Turn the housing counterclockwise until the inner switch housing cap and plug button This feature gives you the option of installing switch housing screws 69 are firmly situated in the narrow end of the the fan with OR without the included light fixture If you want to install the keyhole slots Install the remaining screw into the housing Tighten all light fixture proceed with Step 9 4 now If you do not want to install the light fixture you need to remove it now See Removing the Light Fixture on Step 9 10 three screws firmly Once you have removed the light fixture continue with Step 9 4 16 42798 01 09 16 09 Hunter Fan Company 9 Completing Your Installation With or Without a Bowl Light Fixture cont Bi f A ooo ia ae N SS a Note Both plug p a Hi gt Fi conn
16. s 1 Each step is illustrated at the top of the page The steps are numbered on the side of each illustration 2 Text instructions beneath each illustration describe the procedure for each step 3 On the right side of each image you will find a life sized illustration of necessary hardware At the bottom of each illustration there is a small image that depicts the tools needed for each step Each image correlates to the following legend Screwdriver Phillips head Wrench Screwdriver Flat head Hammer Drill with 3 5 mm bit or masonry bit used only for concrete ceilings Tape Measure Allen Wrench 2 42798 01 09 16 09 Hunter Fan Company gt Checking Your Fan Parts Carefully unpack your fan to avoid damage to the fan parts Refer to the included Parts Guide Check for any shipping damage to the motor or fan blades If any parts are missing or damaged contact your Hunter dealer or call Hunter Technical Support Department at 888 830 1326 If you are installing more than one fan keep the fan blades and blade irons if applicable in sets as they were shipped Optional Accessories Consider using Hunter s optional accessories including a wall mounted or remote speed control To install and use the accessories follow the instructions included with each product For ceilings higher than 8 feet you can purchase Hunter extension downrods All Hunter fans use sturdy 3 4 diameter pipe to assure stabilit
17. sh motor reversing switch fi rmly left or right to ensure that e The chain uses a breakaway connector that separates if the the switch is engaged chain is jerked If this happens simply reinsert the chain into Pull the pull chain to ensure it is on the connector Remove the shipping bumpers The light pull chain controls the power to the light fixture e The chain has two settings ON and OFF Problem Noisy operation Other Hunter Products e Tighten the blade assembly screws and blade iron armature Wumidifers screws until snug Oscillating Fans e Check to see if a blade is cracked If so replace all the blades FES _ NY a numm gt Problem Excessive wobbling If your fan wobbles when operating use the enclosed balancing kit and instructions to balance the fan Tighten all blade iron screws Turn power off support fan very carefully and check that the hanger ball is properly seated If you have tried these troubleshooting solutions and still have trouble visit our Web site at http www hunterfan com Hunter Fan Company 7130 Goodlett Farms Parkway 400 Memphis Tennessee 38016 To learn more about Hunter Fan Company products please see our Web page at www hunterfan com 22 42798 01 09 16 09 Hunter Fan Company
18. with wiring use a qualified electrician 4 42798 01 09 16 09 Hunter Fan Company A CAUTION To avoid possible electrical shock before installing your fan Drill two 9 64 pilot holes into the wood support structure through the disconnect the power by turning off the circuit breakers to the outlet box outermost holes in the outlet box and associated wall switch location If you cannot lock the circuit breakers in the off position securely fasten a prominent warning device such as a tag to the service panel Your ceiling mounting plate 2 comes with four pre installed noise Thread the lead wires from the outlet box down through the hole in the isolators 71 Check to make sure all four isolators are in place and were middle of the ceiling mounting plate 2 not removed during shipment 5 42798 01 09 16 09 Hunter Fan Company Note The isolators must be flush against the ceiling A loose ceiling mounting plate will result in improper operation of the Auto Balance system Align the slotted holes in the ceiling mounting plate 2 with the pilot Place a flat washer 68 on each of the two 3 wood screws 65 Insert holes you drilled in the wood support structure For proper alignment use the screws into the slotted holes in the ceiling mounting plate 2 into the slotted holes directly across from each other pilot holes you drilled Tighten the screws 65 int
19. y and wobble free performance For quiet and optimum performance of your Hunter fan use only Hunter speed controls and accessories READ THIS ENTIRE MANUAL CAREFULLY BEFORE BEGINNING INSTALLATION SAVE THESE INSTRUCTIONS Use only Hunter replacement parts To reduce the risk of personal injury attach the fan directly to the support structure of the building according to these instructions and use only the hardware supplied To avoid possible electrical shock before installing your fan disconnect the power by turning off the circuit breakers to the outlet box and associated wall switch location If you cannot lock the circuit breakers in the off position securely fasten a prominent warning device such as a tag to the service panel All wiring must be in accordance with national and local electrical codes and ANSI NFPA 70 If you are unfamiliar with wiring use a qualified electrician To reduce the risk of personal injury do not bend the blade attachment system when installing balancing or cleaning the fan Never insert foreign objects between rotating fan blades To reduce the risk of fi re electrical shock or motor damage do not use a solid state speed control with this fan Use only Hunter speed controls 1 Getting Ready continued Step 1 Choose the Fan Site Proper ceiling fan location and attachment to the building structure are essential for safety reliable operation maximum efficiency and energy savin

Download Pdf Manuals

image

Related Search

Related Contents

  三菱電機 低温用集中コントローラ MELTOUCH 取扱説明書  取扱説明書  Osciloscopios Infiniium  LC-32SH130E Operation  WEBプログラマ  Tropimed User Guide  Tele Atlas 1029756 navigation software  Manual del usuario  User`s Manual (French)  

Copyright © All rights reserved.
Failed to retrieve file