Home
Honeywell 9500 GPS Receiver User Manual
Contents
1. Welcome to the Honeywell Net Base KKKKKKKKKKKKK KKK EKER KEKE KE KKKKKKKKKKK KK KK KKK KEKE S D00032Login handheld Password View System Configuration View Current Values Express Setup Advanced Setup System Statistics System Diagnostics Hel p Exit x HUD Sw D Ha Enter choice 3 5 Enter choice 3 Express Setup and enter the configuration information requested at each prompt 6 Press OFF on the power adapter and reconnect the Ethernet cable 7 Press ON on the power adapter The Net Base boots up using the configuration information entered in Step 5 Accessing the Net Base Through a Browser When the Net Base is powered on connected to the workstation and you have obtained its IP address you can access the Net Base through your internet browser 1 Open your internet browser 2 Inthe Address line type the IP address assigned to the Net Base and press ENTER 3 The login screen appears showing the Current Values 4 Enter the Username and Password and click Log On 5 The home screen appears Honeywell Dolphin Net Base v1 15 Kernel version 1 10 0708 141639 Host D3100236 MAC 00 10 20 7C 0D 60 Log Off Link Bar Current Values Interface IP Address Ethemet Netmask Ethernet Broadcast Default Gateway USB Port 0 Alias USB Port 1 Alias USB Port 2 Alias USB Port 3 Alias USB Server USB Port 3 192 168 55 203
2. Link Click this link to User s Guide Open the online help files Setup Choose IP address assignments from two options e Obtain all IP addresses dynamically Requests five IP addresses from a DHCP server one is used for the Ethernet interface and the remaining four are assigned to each terminal slot Specify IP addresses manually Enables you to specify IP addresses per terminal slot and change the local USB port PPP IP address Run Spanning Tree Protocol STP Enable or disable STP STP is enabled by default and helps eliminate redundancy in the network Current Values Display the current values this is the default screen Statistics Display the following system statistics Iface The type of interface Docked Charging status Connect Status of an active PPP session RX TX Total Total bytes received transmitted RX TX bps Instantaneous bits per second RX TX peak Peak bits per second Diagnostics Choose from available diagnostic options such as pinging the network host Mounting Options The bottom panel offers two mounting options 1 a DIN Rail for desk mounting or 2 a wall mount kit for wall mounting Both the DIN Rail and wall mount kits need to be purchased separately Using the DIN Rail Use a standard 7 5mm high X 35mm wide DIN Rail to mount the Net Base to a horizontal surface such as a desk or table Installation Hardware Scre
3. which means that if any provision is held invalid and unenforceable such determination shall not affect the validity of enforceability of the other provisions hereof Use of any peripherals not manufactured sold by Honeywell may result in damage not covered by this warranty This includes but is not limited to cables power supplies power adapters cradles and docking stations 14 Honeywell extends these warranties only to users of the products These warranties are non transferable The limited duration of the warranty for the Dolphin Net Base is one year How to Extend Your Warranty Honeywell offers a variety of service plans on our hardware products These agreements offer continued coverage for your equipment after the initial warranty expires For more information contact your Sales Representative Customer Account Representative or Product Service Marketing Manager from Honeywell or your Authorized Reseller 15 16 Disclaimer Honeywell International Inc Honeywell reserves the right to make changes in specifications and other information contained in this document without prior notice and the reader should in all cases consult Honeywell to determine whether any such changes have been made The information in this publication does not represent a commitment on the part of Honeywell Honeywell shall not be liable for technical or editorial errors or omissions contained herein nor for incidental
4. 1 1 2 screw and washer to attach the bracket to the wall For any of the screws positioned so that they are going directly into dry wall use a sheet rock anchor screw set such as the one listed below For any of the screws attaching directly into concrete drill the appropriately sized pilot hole into the concrete and secure the bracket to the wall using concrete anchor screws such as those listed below Wall Recommended Anchors Sheet Rock Buildex E Z Anchor Stud Solver Medium Duty Drywall Anchor Model 25216 supports 50 Ibs screws included Wall Recommended Anchors Concrete Buildex TAPCON concrete anchors 3 16 in X at least 1 in 11 Technical Assistance If you need assistance installing or troubleshooting please call your Distributor or the nearest technical support office North America Canada Telephone 800 782 4263 Fax number 315 554 6705 E mail natechsupport handheld com Latin America Telephone 803 835 8000 Telephone 800 782 4263 E mail latechsupport handheld com Brazil Telephone 55 21 3535 9100 Fax 55 21 3535 9105 E mail brsuporte handheld com Mexico Telephone 803 835 8000 E mail latechsupport handheld com Europe Middle East and Africa Telephone 31 0 40 7999 393 Fax 31 0 40 2425 672 E mail eurosupport handheld com Asia Pacific Telephone Hong Kong 852 31 88 3485 or 2511 3050 Telephone China 86
5. and Honeywell determines to its satisfaction that the product is defective due to defects in materials or workmanship Honeywell at its sole option will either repair or replace the product without charge except for return shipping to Honeywell EXCEPT AS MAY BE OTHERWISE PROVIDED BY APPLICABLE LAW THE FOREGOING WARRANTY IS IN LIEU OF ALL OTHER COVENANTS OR WARRANTIES EITHER EXPRESSED OR IMPLIED ORAL OR WRITTEN INCLUDING WITHOUT LIMITATION ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE HONEYWELL S RESPONSIBILITY AND PURCHASER S EXCLUSIVE REMEDY UNDER THIS WARRANTY IS LIMITED TO THE REPAIR OR REPLACEMENT OF THE DEFECTIVE PRODUCT WITH NEW OR REFURBISHED PARTS IN NO EVENT SHALL HONEYWELL BE LIABLE FOR INDIRECT INCIDENTAL OR CONSEQUENTIAL DAMAGES AND IN NO EVENT SHALL ANY LIABILITY OF HONEYWELL ARISING IN CONNECTION WITH ANY PRODUCT SOLD HEREUNDER WHETHER SUCH LIABILITY ARISES FROM A CLAIM BASED ON CONTRACT WARRANTY TORT OR OTHERWISE EXCEED THE ACTUAL AMOUNT PAID TO HONEYWELL FOR THE PRODUCT THESE LIMITATIONS ON LIABILITY SHALL REMAIN IN FULL FORCE AND EFFECT EVEN WHEN HONEYWELL MAY HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH INJURIES LOSSES OR DAMAGES SOME STATES PROVINCES OR COUNTRIES DO NOT ALLOW THE EXCLUSION OR LIMITATIONS OF INCIDENTAL OR CONSEQUENTIAL Pan SO THE ABOVE LIMITATION OR EXCLUSION MAY NOT APPLY TO YOU All provisions of this Limited Warranty are separate and severable
6. on the Dolphin terminal 5 When you exit RASMan or remove the terminal from the Net Base the terminal plays a sound and the disconnected icon appears in the Navigation bar Configuring the Network By default the Net Base is configured to obtain IP addresses automatically via DHCP server This means that in most cases you would simply plug and play the unit If necessary you can use the configuration utility for dynamic network configuration If Your DNS Server Supports Bind 8 3 or Later 1 Obtain the serial number from the label on the bottom panel of the Net Base 2 Connect to the network 3 Power up and wait until the COMM LEDs stop flashing The COMM LEDs stop flashing when the Net Base has found the DHCP server 4 On your workstation open the web browser and enter the Net Base serial number exactly as it appears on the label 5 Press ENTER and the online configuration utility displays on the workstation If Your DNS Server Does Not Support Bind 8 3 or Later If your DNS server does not support Bind version 8 3 or later Hyperterminal or an equivalent terminal emulator program must be installed on the host workstation to configure the Net Base 1 Connect the serial cable to the Serial DB 9 Connector on the back of the Net Base and a COM port on the host computer 2 Start Hyperterminal or an equivalent terminal emulator program Use these settings 115200 bps 8 N 1 3 Power up and wait until
7. the COMM LEDs have stopped flashing The COMM LEDs stop flashing when the Net Base has found the DHCP server 4 Enter the user name lt handheld gt and default login password lt handheld gt to log into Net Base configuration utility The Net Base menu program displays KRKKKK KK KKK KKK KK KKK KKK KKK KKK XXX X X X Welcome to the Honeywell Net Base KKKKKKKKKKKKK KKK KEKE KEKE KE KKKKKKKKKKK KK KKK KKK KES SD00032Login handheld Password x View System Configuration View Current Values Express Setup Advanced Setup System Statistics System Diagnostics Hel p Exit x SH SO QI Sw D ee Enter choice 2 Enter choice 2 View Current Values to display IP addresses Record the IP address for the Ethernet port 7 Open the web browser on your workstation and enter the IP address for the Net Base you wrote down in Step 6 8 Press ENTER and the online configuration utility displays on your workstation Configuring the Net Base with a Static IP Address 1 Connect the serial cable to the Serial DB 9 Connector on the back of the Net Base and a COM port on the host computer Do NOT connect to the network at this time 2 On the workstation start Hyperterminal Use these settings 115200 bps 8 N 1 3 Wait until login prompt displays on Hyperterminal 4 Enter the user name lt handheld gt and default login password lt handheld gt to log into network A EE EE EE XXX X X
8. 21 6361 3818 E mail aptechsupport handheld com Japan Telephone 813 5770 6312 E mail aptechsupport handheld com Malaysia Telephone 603 6201 7020 E mail aptechsupport handheld com Online Technical Assistance You can also access technical assistance online at www honeywell com aidc 12 Product Service and Repair Honeywell provides service for all its products through service centers throughout the world To obtain warranty or non warranty service contact the appropriate location below to obtain a Return Material Authorization number RMA before returning the product North America Telephone 800 782 4263 Fax 803 835 8012 E mail naservice handheld com Latin America Telephone 803 835 8000 Telephone 800 782 4263 Fax 239 263 9689 E mail laservice handheld com Brazil Telephone 55 21 3535 9100 Fax 55 21 3535 9105 E mail brservice handheld com Mexico Telephone 52 55 5203 2100 Fax 52 55 5531 3672 E mail mxservice handheld com Europe Middle East and Africa Telephone 31 0 40 2901 633 Fax 31 0 40 2901 631 E mail euservice handheld com Asia Pacific Telephone 852 2511 3050 Fax 852 2511 3557 E mail apservice handheld com Japan Telephone 813 5770 6312 Fax 813 5770 6313 E mail apservice handheld com Online Product Service and Repair Assistance You can also access product service and repair assistance online at www hon
9. Honeywell Dolphin Net Base Four Slot Charging Communication Cradle for the Dolphin 7900 Mobile Computer Dolphin 9500 Mobile Computer Dolphin 9900 Mobile Computer Quick Start Guide Dolphin Net Base Quick Start Guide Introduction The Net Base charges up to four mobile computers and enables each one to communicate with a host device over an Ethernet network Use only the peripherals power cables and power adapters from Honeywell Use of peripherals cables or power adapters not sold manufactured by Honeywell may cause damage not covered by the warranty Unpacking the Net Base Open the shipping box and inspect the package to see that the following standard items are included One Dolphin Net Base Ethernet cradle One universal AC DC power adapter for the Dolphin Net Base One power cord One serial extension cable These are the items you need to set up configure and operate the Net Base If any items are missing or anything appears to be damaged contact your Customer Account Representative Keep the original packaging in case you need to return the Net Base for service or store the Net Base while not in use Software Requirements Before you connect the Dolphin terminal to the Net Base make sure you have the most current software installed To check this go to Start gt Power Tools gt Sysinfo Applications on the Dolphin Terminal Applications running on the Dolphin terminal when it is con
10. eywell com aidc 13 Limited Warranty Honeywell International Inc Honeywell warrants its products to be free from defects in materials and workmanship and to conform to Honeywell s published specifications applicable to the products purchased at the time of shipment This warranty does not cover any Honeywell product which is i improperly installed or used ii damaged by accident or negligence including failure to follow the proper maintenance service and cleaning schedule or iii damaged as a result of A modification or alteration by the purchaser or other party B excessive voltage or current supplied to or drawn from the interface connections C static electricity or electro static discharge D operation under conditions beyond the specified operating parameters or E repair or service of the product by anyone other than Honeywell or its authorized representatives This warranty shall extend from the time of shipment for the duration published by Honeywell for the product at the time of purchase Warranty Period Any defective product must be returned at purchaser s expense during the Warranty Period to Honeywell s factory or authorized service center for inspection No product will be accepted by Honeywell without a Return Materials Authorization which may be obtained by contacting Honeywell In the event that the product is returned to Honeywell or its authorized service center within the Warranty Period
11. nected to the Net Base should be designed specifically for a partially connected network For more details please refer to the Best Practices for Partially Connected Networks document available at www honeywell com aidc Hardware Overview Front Panel Terminal Wells Dock LED COMM LED Dock LED Lights solid green when the terminal is properly seated The terminal can communicate with the Net Base only when properly seated in the well COMM LED Indicates the status of data transfer between the Dolphin terminal and the Net Base Solid Green Indicates a USB connection Flashing Orange Indicates that data is being transferred Back Panel Serial DB 9 Port Power Connector Two RJ 45 Ethernet Connectors Bottom Panel For details about the bottom panel see Mounting Options page 1 9 Power Supply Power Adapter ON OFF Switch Connector Power Cord Setting up the Net Base 1 2 3 Make sure the ON OFF switch on the power adapter is in the OFF position Plug the power cord into the power adapter Plug the power connector cable into the power connector on the back of the Net Base Plug the power cord into a standard wall outlet Plug the CAT 5 Ethernet cable into either of the RJ 45 connectors on the back of the Net Base Plug the Ethernet cable into the network On the power adapter turn the ON OFF switch to the ON position The COMM LED
12. or consequential damages resulting from the furnishing performance or use of this material This document contains proprietary information that is protected by copyright All rights are reserved No part of this document may be photocopied reproduced or translated into another language without the prior written consent of Honeywell 2005 2008 Honeywell International Inc All rights reserved Web Address www honeywell com aidc Trademarks Dolphin Dolphin RF HomeBase Mobile Base and QuadCharger are trademarks or registered trademarks of Hand Held Products Inc or Honeywell International Inc Microsoft Windows Windows Mobile Windows CE Windows NT Windows 2000 Windows ME Windows XP ActiveSync Outlook and the Windows logo are trademarks or registered trademarks of Microsoft Corporation Other product names mentioned in this manual may be trademarks or registered trademarks of their respective companies and are the property of their respective owners Patents Please refer to the product packaging for a list of patents Honeywell 700 Visions Drive P O Box 208 Skaneateles Falls NY 13153 0208 NETBASEALL QS TI N TI HN N TN NI Es 7 1 08
13. s on all four slots flash binary codes as the Net Base finds the DHCP server during the bootloader and kernel sequences Charging Use any the Li ion battery packs provided by Honeywell Use of any battery A not sold manufactured by Honeywell may result in damage not covered by the warranty The Net Base charges the main battery of each terminal in less than four hours The intelligent battery charging system incorporated into all Dolphin terminals prevents overcharging which means that Dolphin terminals may be stored in the Net Base indefinitely without damage to the terminals battery packs or the Net Base 1 Install the Li ion battery pack into the back panel of the terminal 2 Slide the Dolphin terminal into one of the terminal wells until the Dock LED lights solid green Charging begins immediately Connecting the Dolphin Terminal to the Net Base After the Net Base is installed configured and connected to the host computer you must connect the Dolphin terminal to the Net Base 1 Insert a Dolphin terminal into a terminal well 2 Onthe Dolphin terminal tap Start gt Power Tools gt RASMan The RASMan utility initializes 3 When the connection is established between the Dolphin terminal and the Net Base the terminal plays a sound and the communication icon appears in the Navigation bar 4 Upon connection the Dolphin terminal is assigned an IP address from the Net Base which can be used by any application
14. w 3 16 in dia x 5 8 in long pan head screw Washer 1 2 in OD x 7 82 in ID x 3 64 in thick Nut 3 16 in dia 1 Slide the DIN Rail into the slot on the bottom panel 2 Turn the Net Base and DIN Rail right side up 3 Secure the DIN Rail to the horizontal mounting surface Using the Wall Mount Kit You need to purchase two wall mount kits that each contain a mounting bracket e three screws and six washer nut sets You need two kits so that you have two mounting brackets one for each end of the device and enough screws 4 and washer nut sets 8 The mounting bracket contains an open slot between the back and bottom wedges to accommodate the connector cables To Mount a ChargeBase Device 1 Attach the mounting bracket to the wall using the Recommended Hardware see page 1 10 2 Oneach end of the ChargeBase device insert a screw into the round end of each of the four screw slots on the bottom panel Then slide each screw towards the narrow end of the slot until it snaps in place 3 Use a washer nut set on each of the four screws to secure the screw in the slot 4 Place the ChargeBase device on the mounting bracket match the holes up with the secured screws 5 Use the remaining washer nut sets on each of the four screws to secure the ChargeBase device to the mounting bracket Recommended Hardware If a metal or wood stud is present drill a 3 32 in pilot hole into the stud and use a 6 X
Download Pdf Manuals
Related Search
Related Contents
Irinotécan Labatec - Labatec Pharma SA OPERATION AND MAINTENANCE MANUAL Specification sheet (English) New Title Speditionsabrechnung - der PRAXIS Software AG 3A2546N - Stainless Steel Tank Stands Instructions rapid park TAFCO WINDOWS NU2-112S-W Installation Guide DGUS_SDK User Guide Copyright © All rights reserved.