Honeywell 5800ZBRIDGE Home Security System User Manual
Contents
1. la norme NMB 003 du Canada FCC IC Statement This device complies with Part 15 of FCC Rules and RSS 210 of Industry Canada Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 This device must accept any interference received including interference that may cause undesired operation Cet appareil est conforme a la partie 15 des r gles de la FCC amp de RSS 210 des Industries Canada Son fonctionnement est soumis aux conditions suivantes 1 Cet appareil ne doit pas causer d interferences nuisibles 2 Cet appareil doit accepter toute interference re ue y compris les interferences causant une reception ind sirable WARRANTY INFORMATION For the latest warranty information please go to www honeywell com security hsc resources wa Honeywell 2 Corporate Center Drive Suite 100 P O Box 9040 Melville NY 11747 Copyright 2011 Honeywell International Inc www honeywell com securit 800 08932 5 11 Rev A
2. GE control When press the first 5800ZBRIDGE button the light flashes red one time and stops After the System goes into alarm entered the code but the 5800ZBRIDGE still blinks orange 5800ZBRIDGE can control up to four 4 Z Wave devices The System needs to have a green ready on the keypad you need to disarm the system again to clear the memory 2 SPECIFICATIONS Dimensions 4 5 H x 2 75 W x 0 25 D 114 3 mm x 69 85 mm x 6 385 mm Power 12VDC Power Supply Environmental Conditions 14 to 122 F 10 to 50 C lt 90 RH non condensing Frequency 345 MHz from 5800 Series TM Code receiver 908 42 MHz from Z Wave controller Range Up to 100 feet 30 48 m using 5800 Series wireless devices and 75 feet 22 86 m from Z Wave devices Supports Any combination of up to four Z Wave enabled thermostats or Z Wave enabled light devices Compatibility 5800 Series Wireless TM code and Z Wave enabled thermostats and light devices Note The Honeywell Z Bridge is a certified Z Wave controller and as can be operated in one Z Wave network with Z Wave certified devices from other manufacturers The different listening nodes within the network may act as repeaters regardless of vendor The Z Bridge controls devices though use of the Basic Command Class the Z Bridge controller does not respond too or map received basic command to any functions FCC and Industry Canada Statement Federal Communications Commi
3. Honeywell 800 08932 5 11 Rev A 5800ZBRIDGE Z Bridge Module INSTALLATION AND SETUP GUIDE GENERAL INFORMATION 5800ZBRIDGE is a wireless intelligent energy management device that provides an interface between Z Wave Modules and Honeywell LYNX Security Systems and VISTA Control Panels that are equipped with RF keypads Note The 5800ZBridge is not compatible with the 5800TM or 5883H modules Features e Automatically set back Z Wave enabled thermostat when security system is Armed AWAY e Automatically turns lights off when security system is Armed AWAY e Sends run command to Z Wave enabled thermostat when security system is Disarmed e Automatically turns lights on when security system is Disarmed e Alarm Status light Ready Armed Away and Stay e Will function with any Z Wave device MOUNTING 1 Determine the optimum mounting location taking care to avoid damp locations To maximize the transmitter s range avoid mounting the device to metal objects if possible The module should be located a maximum of 6 feet from an unswitched 120VAC outlet 2 Open the 5800ZBRIDGE case as shown in Figure 1 3 Mount the 5800ZBRIDGE using the provided screws Refer to Figure 2 5800Z 002 VO Figure 1 Opening the 5800ZBRIDGE POWER UP MODULE 1 Plugin 12VDC power supply LED flashes ORANGE 3 times and then goes out Refer to Figure 2 PROGRAMMING Enroll 5800TM Code into Module 1 Press SW5 LEARN swi
4. SW5 TM code has been deleted and 5800ZBRIDGE has been deleted excluded from the Z Wave network 4 Unplug the 12VDC power supply and plug it back in to the 5800ZBRIDGE 5 Program the 5800ZBRIDGE in accordance with the PROGRAMMING section Deleting excluding Z Wave modules devices Delete exclude Z wave modules devices from the 5800ZBRIDGE when they are no longer required 1 Press and hold 5 seconds the SW1 SW2 SW3 or SW4 switch as applicable to remove a device 2 Release the switch 3 The 5800ZBRIDGE LED will begin flashing RED 4 Press the Z Wave device to allow host to delete exclude the module 5 The LED will stop flashing RED and return to status of security panel Include Exclude Receive Primary Role of 5800ZBRIDGE to from another Z Wave Network 1 Set another Z Wave controller into Include Exclude or Controller Shift mode 2 Press and hold SW1 and SW2 on the 5800ZBRIDGE for 5 seconds LED will blink between GREEN and ORANGE Note The LED will blink until process finishes or times out 5 seconds 3 Ifthe process is successful the LED will turn GREEN times out the LED stops blinking fails the LED will turn RED Note If the Z Bridge has been removed from a network it is recommended the user installer rest the Z Bridge device Relinquish shift Primary Role to another control within a Z Wave Network 1 Press and Hold SW3 and SW4 on the 5800ZBRIDGE for 5 Seconds LED will alte
5. rnately blink RED and ORANGE 2 Put other Z Wave controller into Learn Mode Note The LED will blink until process finishes or times out 30 seconds 3 Ifthe process is successful the LED will turn GREEN times out the LED stops blinking fails the LED will turn RED TESTING 1 Test each device by arming and disarming security system Refer to Table 2 for System Operation NORMAL OPERATION 1 When the Security System is armed or disarmed it will operate as noted in Table 2 2 Ifthe Security System has gone into alarm the 5800ZBRIDGE LED will flash ORANGE To reset the module you will need to clear the Alarm by disarming the system two times enter two OFF sequences via the keypad or keyfob Table 2 ZBRIDGE System Operation Armed AWAY Thermostat Set back Energy Save mode Lights OFF Armed STAY Thermostat normal run mode Lights ON Disarm Thermostat normal run mode Lights ON MANUAL OPERATION Connect a jumper wire between screw terminals on the 5800ZBRIDGE This will activate the device and send the Z Wave setback command The LED will indicate the system operation by illuminating as follows RED Sent Setback command GREEN Sent Release Setback command II 12 VDC POWER SUPPLY RECEPTACLE HOLES 2 5800Z 001 VO FIGURE 2 5800ZBRIDGE FREQUENTLY ASKED QUESTIONS AND TROUBLESHOOTING Question Answer How many devices can the 5800ZBRID
6. ssion FCC Part 15 The user shall not make any changes or modifications to the equipment unless authorized by the Installation Instructions or User s Manual Unauthorized changes or modifications could void the user s authority to operate the equipment CLASS B DIGITAL DEVICE STATEMENT NOTE This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help This Class B digital apparatus complies with Canadian ICES 003 Cet appareil num rique de la classe B est conforme a
7. tch for 1 second and release LED will begin flashing ORANGE 2 Disarm or Arm the control panel with 5800TM code turned on The LED will stop flashing ORANGE and the color will follow status of the control panel Note The module will time out of program mode after 3 minutes if no TM code is enrolled Table 1 5800ZBRIDGE LED Indications Indication Meaning Flashing Red Armed AWAY Steady Red Armed STAY Solid Green Ready Flashing Orange ALARM Panic Note Following an alarm the User Code must be entered twice and the keypad must go to ready in order for the Z Bridge Module to release thermostat setback and or turn on lights Enroll include Devices in Z Wave Modules into 5800ZBRIDGE module 1 Press the corresponding switch SW1 through 4 for 1 second and release for any combination of four Thermostats or Lights Refer to Figure 2 2 The 5800ZBRIDGE LED will begin flashing Green 3 Press button on the respective Z Wave device to learn include the device The 58300ZBRIDGE LED will stop flashing GREEN and return to status of control panel 4 Repeat for each Z Wave device as applicable Note The module will time out of program mode after 2 minutes if no Z Wave device in enrolled included Reset 5800ZBRIDGE Module 1 Disconnect the 12VDC power supply 2 Press and hold SW5 LEARN switch and then plug in 12VDC power supply LED flashes Orange 5 times and then goes out 3 Release switch