1. basic safety precautions should always be followed including the following Failure to follow instructions may result in injury READ AND FOLLOW ALL INSTRUCTIONS IN THIS OWNER S MANUAL AND ON EOUIPMENT KEEP SAFETY LABELS IN GOOD CONDITION AND REPLACE IF MISSING OR DAMAGED A WARNING To reduce risk of injury do not permit children to use or climb on this product The ANSI NSPI 4 Standard above ground and on ground pools advises that components such as the filtration system pumps and heaters be positioned to prevent their being used as a means of access to the pool by young children Closely supervise children at all times A CAUTION The XStream Filtration Series is intended for use on permanently installed above ground swimming pools and may also be used with hot tubs and spas if so marked Do NOT use with storable pools A permanently installed pool is constructed 1n or on the ground or in a building such that it cannot be readily disassembled for storage A storable pool is constructed so that it is capable of being readily disassembled for storage and reassembled to its original integrity Though this product is designed for outdoor use 1t is strongly advised to protect the electrical components from the weather Select a well drained area one that will not flood when it rains It requires free circulation of air for cooling Do not install in a damp or non ventilated location Bond motor to pool structure Use a solid c
2. 8a CCX1000RE Cartridge Element 100 sq ft 1 1 8b CCX1500RE Cartridge Element 150 sq ft 1 1 9 CCX1000B Filter Lower Body 1 1 10 SP1480BLK Self Aligning Union Black 50 1 lla SP1592 1 HP Power Flo Matrix Pump 1 1 llb SP1593 1 1 2 HP Power Flo Matrix Pump 1 1 12 CCX1000A Base Standard 1 1 13 SP1022CBLK Drain Plug with O Ring 100 1 14 CCX1000G Body O ring 2 1 15 SPX1500W Pressure Gauge O Ring 10 1 16 CCX1000Z5 O Rings for Gauge Adapter amp Air Relief Set of 2 10 1 XStream Filtration Series HAYWARD LIMITED WARRANTY This filter system was inspected before shipment from our plant To original purchasers of this filter system Hayward Pool Products Inc 620 Division Street Elizabeth New Jersey warrants its products free from defects in materials and workmanship for a period of ONE 1 year from the date of purchase Parts which fail or become defective during the warranty period except as a result of freezing negligence improper installation use or care shall be repaired or replaced at our option without charge within 90 days of the receipt of defective product barring unforeseen delays Additionally to original purchasers of this filter system Hayward Pool Products Inc warrants its filter heads and filter bodies made of Perma Glass XL material to be free from defects in materials and workmanship for a period of ONE 1 year from the date of purchase Filter heads and filter bodies which becom
3. Elizabeth NJ 07207 A Retain this Warranty Certificate upper portion in a safe and convenient location for your records VW DETACH HERE Fill out bottom portion completely and mail within 10 days of purchase installation Mail to Hayward Pool Products Inc 620 Division Street Elizabeth NJ 07207 Attn Warranty Dept Warranty Registration Card Name Years pool has been in service Lllessthanl O 1 3 13 5 15 10 Address Purchased from Company name City State Zip Address E mail Address City State Zip Product Purchased Product Serial No Please send me more information on these other O New Installation Ll Replacement products from Hayward Type of Pool Ll Pump O Filter O Automatic Pool Cleaner CO In ground Ll Vinyl Ll Fiberglass Ll Gunite Ll Above ground Ll Light Ll Chlorinator LJ Skimmer Ll Heater Size of Pool
4. ISCC100 Rev D HAYWARD OWNER S MANUAL INSTALLATION OPERATION amp PARTS AStreamrM Filtration Series The Hayward XStream Filtration Series is specifically designed for the demanding requirements of today s above ground swimming pools The advanced design reduces maintenance reguirements while providing superior performance To prevent potential injury and to avoid unnecessary service calls read this manual carefully and completely AY CAUTION We highly recommend a qualified professional install and service this product AY WARNING This manual contains important safety information that must be furnished to the end user of this product FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS COULD RESULT IN SERIOUS INJURY SAVE THIS INSTRUCTION MANUAL Corporate Headquarters 620 Division Street Elizabeth NJ 07207 Canada 2880 Plymouth Drive Oakville Ontario L6H 5R4 HAYWARD POOL PRODUCTS INC U S A 1 Hayward Industrial Drive 2935 Sidco Drive 2875 Pomona Blvd Clemmons NC 27012 Nashville TN 37204 Pomona CA 91768 Europe Parc Industriel de la plaine de l Ain All e des Ch nes 01150 Saint Vulbas France XStream Filtration Series PRODUCT REGISTRATION Retain For Your Records DATE OF INSTALLATION INITIAL PRESSURE GAUGE READING CLEAN FILTER PUMP MODEL HORSEPOWER FILTER MODEL SERIAL NUMBER IMPORTANT SAFETY INSTRUCTIONS When installing and using this electrical equipment
5. e defective during the warranty period except as a result of freezing negligence improper installation use or care or as a result of use in association with an automatic valving system shall be repaired or replaced at our option without charge To obtain warranty replacements or repair defective components or parts should be returned transportation paid to the place of purchase or to the nearest authorized Hayward service center For further Hayward dealer or service center information contact Hayward customer service department No returns may be made directly to the factory without the express written authorization of Hayward Pool Products Inc All other conditions and terms of the standard warranty apply Hayward shall not be responsible for cartage removal and or reinstallation labor or any other such costs incurred in obtaining warranty replacements The Hayward Pool Products warranty does not apply to components manufactured by others For such products the warranty established by the respective manufacturer will apply Some states do not allow a limitation on how long an implied warranty lasts or the exclusion or limitation of incidental or consequential damages so the above limitation or exclusion may not apply to you This warranty gives you specific legal rights and you may also have other rights which vary from state to state Hayward Pool Products Inc 620 Division Street Supersedes all previous publications
6. ed plastic components All plastic fittings must be new or thoroughly cleaned before use NOTE Do NOT use Plumber s Pipe Dope as it may cause cracking of the plastic components When applying Teflon tape to plastic threads wrap the entire threaded portion of the male fitting with one to two layers of tape Wind the tape clockwise as you face the open end of the fitting beginning at the end of the fitting The pump suction and outlet ports have molded in thread stops Do NOT attempt to force hose connector fitting past this stop It is only necessary to tighten fittings enough to prevent leakage Tighten fitting by hand and then use a tool to engage fitting an additional 1 J gt turns Use care when using Teflon tape as friction is reduced considerably do NOT over tighten fitting or you may cause damage If leaks occur remove connector clean off old Teflon tape re wrap with one to two additional layers of Teflon tape and re install connector Use 1 2 I D flexible plastic pipe with hose adapter fittings and hose clamps If rigid PVC is used be sure to install Hayward SP1500UNPAK2 union connectors for easy servicing All plumbing connections on the XStream Filter are 1 2 N P T When making connections use plastic male end adapters Apply three 3 turns of Teflon tape or plastic pipe sealant to the male threads Screw the fitting into the thread hand tight then using a wrench tighten one more full turn if necessary NOTE Adapters ha
7. ge Filter cont To remove algae suntan oil and body oils Soak the cartridge element for at least one 1 hour overnight is most effective in 1 a commercial filter cleaner OR 2 One 1 cup Tri Sodium Phosphate TSP to five 5 gallons water OR 3 One 1 cup dishwasher detergent to five 5 gallons water Rinse cartridge element to remove oils and cleaning solution To remove calcium carbonate residue from calcium hypochlorite iron or other mineral deposits Soak the cartridge element in a solution of one 1 part Muriatic Acid to twenty 20 parts water until all bubbling stops WARNING Do NOT add water to acid AN WARNING Do NOT mix chlorine and acid AY WARNING Use a plastic container and take extreme care harmful to eyes skin and clothing Always wear rubber gloves and eye protection CAUTION lt Failure to remove all oils and cleaning solution before acid soaking will result in a permanent restriction of water flow and cause premature cartridge failure 3 Rinse the cartridge element clean and re assemble filter housing Vacuuming Vacuuming can be performed directly into the filter whenever needed For fastest results clean the filter before and after each vacuuming For heavy spring clean ups we recommend using a Hayward SP0727 diverter valve to bypass the filter and accelerate the clean up process Consult your local Hayward dealer for a detailed explanation Winterization In areas where s
8. l MUST be followed precisely Product Features Engineered for easy use with flexible or rigid plumbing Sleek flush mounted pressure gauge Extra large dirt capacity Quick release high capacity air relief valve Glass reinforced non corrosive Permaglass XL filter tank will provide years of trouble free operation Easy LokTM ring design allows quick access to all internal components in a single turn PREFERRED FILTER LOCATION BELOW WATER LINE Filter Location PUMP WITH STRAINER Set the filter on firm level ground Select a well drained ae CCA area one that will not flood when it rains Position the filter so that it may drain by gravity The tank should be positioned for easy access to the internals pressure gauge and air relief valve IES RAIN VALVE POOL SUCTION SKIMMER 7 J OUTLET POOL RETURN FILTERED OPTIONAL BALL VALVE Da OPTIONAL OUTLET VALVE Not furnished with filfer e Plu mbing NOTE ANSI NSPI 4 Article V standard for above ground and on ground pools advises that components such as the filtration system pumps and heater be positioned so as to prevent their being used as a means of access to the pool by young children To facilitate servicing of the filter system and to allow for indoor storage during the winter months installing union connections at the suction and outlet ports is recommended Use Teflon tape to seal threaded connections on mold
9. mage All drains and suction covers MUST have properly installed covers securely attached with the screws supplied with the covers If screws are lost order replacement parts from your supplier A DANGER Suction Entrapment Hazard Never use the pool or spa if a drain cover is damaged cracked missing or not securely attached Suction in drains and suction outlets can cause drowning disembowelment hair or body entrapment severe injury and death Disembowelment entrapment or drowning is possible when body parts or hair come in contact with damaged broken cracked missing or unsecured drain covers and suction outlets Suction from pumps with only one drain or suction outlet can cause disembowelment entrapment or drowning Pumps for pools and spas require two 2 functioning suction outlets at least three 3 feet apart on two 2 walls or on the floor and one 1 wall of the pool or spa Installation of pump and suction outlets must be in compliance with all applicable local building codes Replace damaged broken cracked missing or unsecured drain covers and suction outlets immediately A WARNING Hazardous Pressure Pumps filters and other equipment components of a swimming pool filtration system operate under pressure Incorrectly installed and or improperly tested filtration equipment and or components may fail resulting in injury and or property damage A qualified pool professional MUST conduct all pressure tests This prod
10. opper conductor size or larger Run wire from external bonding lug to reinforcing rod or mesh Connect a No 8 AWG 8 4 mm solid copper bonding wire to the pressure wire connector provided on the motor housing and to all metal parts of swimming pool spa or hot tub and to all electrical equipment metal piping or conduit within 5 ft 1 5 m of inside walls of swimming pool spa or hot tub In Canada use No 6 AWG bonding wire XStream Filtration Series NOTE The National Electrical Code NEC permits use of a cord with a maximum 3 ft 1 m length If your pump is equipped with a cord complying with the NEC the following three 3 items apply A WARNING Risk of Electric Shock Connect only to a grounding type receptacle protected by a Ground Fault Circuit Interrupter GFCI Contact a qualified electrician if you cannot verify that the receptacle is protected by a GFCI A WARNING To reduce the risk of electric shock replace damaged cord immediately Do NOT bury cord Locate cord to minimize abuse from lawn mowers hedge trimmers and other equipment A WARNING To reduce the risk of electric shock do NOT use an extension cord to connect unit to electric supply Provide a properly located outlet Oualified personnel MUST do all electrical wiring AN WARNING 2 A CAUTION All suction and discharge valves MUST be OPEN when starting the filter system Failure to do so could result in severe personal injury and or property da
11. rn valves Open air relief valve Open drain plug located at the base of the filter body Depress safety latches located on the underside of the locking ring handles and unscrew locking ring in a counter clockwise direction Remove lid from filter body Lift out filter element and clean as instructed in Preventative Maintenance section of this manual Re Installing Cartridge Element A DOE Clean debris from bottom of filter tank Replace element evenly on the collector hub in bottom of the filter body Place lid evenly on filter body and turn Easy Lok ring clockwise until the safety latches engage securely Close and secure drain plug located at the base of filter body Proceed as in Start Up amp Operation Preventative Maintenance Cleaning Cartridge Filter NOTE Clean the cartridge when filter canister pressure reaches 5 7 PSI above the initial system or new cartridge starting pressure l Remove the cartridge element from the filter housing following the directions in the Cleaning Removing Cartridge Element section above Pressure wash the cartridge element inside and out with the Hayward Jet action Cleaning Wand EC2024 or a garden hose with a high pressure nozzle Work from top down holding the nozzle at a 45 degree angle Rinse until all dirt and debris are gone Brush pleated surface areas and allow to dry XStream Filtration Series Preventative Maintenance cont Cleaning Cartrid
12. ub freezing temperatures can be expected the filter should be drained and or removed from its operating location and stored indoors Clean the cartridge element at the end of the pool season by using the Hayward Jet action Cleaning Wand EC2024 or a garden hose with a high pressure nozzle See Cleaning Cartridge Filter instructions in this manual Troubleshooting Problem What to Look for Treatment Damaged Cartridge Element Dirty clogged or abused element Dirt debris or tear in pleats or folds Clean or replace element Flattened pleats or folds Oversized pump Embedded dirt or debris into the Produces filter material excessive Breaking of internal core of the Re size pump flow rates element and or Breaking or splitting of the end pressures plates of the element Frequent cartridge cleaning or Very dirty pool water Algae buildup on the pool walls replacement Consult professional pool company for pool chemistry instructions XStream Filtration Series Replacement Parts Parts Diagram Parts Listing No Part No Description Ctn Oty No Req d 1 ECX27091 Pressure Gauge 10 1 2 CCX1000L Threaded Adapter for Pressure Gauge 10 1 3 CCX1000V Air Relief Assembly with O Ring 10 1 4 CCX1000D Lock Ring Assembly with Latches 1 1 5 CCX1000H Lock Ring Latch 10 2 6a CCX1000C Filter Lid with Lock Ring 100 sg ft 1 1 6b CCX1500C Filter Lid with Lock Ring 150 sg ft 1 1 i CCX1000N Adapter Nut 10 2
13. uct is intended for above ground on ground swimming pool applications only Do NOT connect to a high pressure system such as a municipal water main To prevent explosion caused by entrapped air in the filtration system use provided air relief valve to bleed air from the system Confirm that ALL filtration system component clamps bolts and covers have been tightened to the manufacturer s recommendations N WARNING Never operate or test the filtration system at more than 30 PSI SAVE THESE INSTRUCTIONS XStream Filtration Series Product Specifications From To Pool Pool Skimmer XStream Filtration Components Filter Type Full Flow Cartridge Element Filter Tank Injection Molded PermaGlass XL Filter Element Reinforced Polyester Element Fastenings Easy Lok Ring Assembly Mounting Base Injection Molded PermaGlass XL XStream Filtration Performance Data Effective Filtration Area Design Flow Rate Maximum Working Pressure Required Clearance Replacement Hayward Cartridge CCX1000RE CCX1500RE 38 400 GAL 48 000 GAL Turnover 57 600 GAL 72 000 GAL XStream Filtration Series General Information Installation Instructions Introduction This manual contains information for the proper installation and operation of the Hayward XStream Filtration Series All _XStream Filtration models are high performance above ground swimming pool filters Instructions in this manua
14. ve varying tolerances and over tightening with a wrench may only cause damage to the filter Ball type valves are recommended where needed Connect the pool suction plumbing between the skimmer and the pump Connect the pool return plumbing to the OUTLET port at the bottom of the filter body A filter drain or plug is furnished with each filter and is all that is needed for complete filter draining A manual air relief valve is furnished to aid in the bleeding of unwanted air when starting or draining the filter XStream Filtration Series Start Up amp Operation New Installation Seasonal Start Up NN T Close drain valve at the base of filter Secure and lock Easy Lok ring Open air relief valve Turn lever to left Open valves Optional suction amp return valves A CAUTION All suction and outlet valves MUST be OPEN before operating the filter system Failure to do so could cause severe personal injury and or property damage 5 6 Prime and start the pump per manufacturer s instructions Once air has escaped the filter and a steady stream of water is flowing from the air relief valve close the air relief valve and note the pressure gauge reading Dis Assembly amp Assembly Cleaning Removing Cartridge Element NOTE An indication that the filter needs cleaning is when the pressure gauge rises 5 7 PSI above its normal pressure hee Daar Shut off the pump Close valves optional suction amp retu