Home
Harman Stove Company PC 45 Stove User Manual
Contents
1. SAFETY NOTICE IF THIS HARMAN STOVE IS NOT PROP ERLY INSTALLED A HOUSE FIRE MAY RESULT FOR Table of Contents YOUR SAFETY FOLLOW THE INSTALLATION DIREC Assembly amp Installation TIONS CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT RESTRICTIONS AND INSTALLATION INSPECTION Installation REQUIREMENTS IN YOUR AREA Venting Automatic Operation ESP Control Maintenance Trouble Shooting Feeder Parts Specifications Options Wiring Diagram Harman Stove Company p biet 352 Mountain House Road arts Lis sales harmanstoves com PC 45 Corn Pellet Stove 3 Assembly and Installation Unpacking O The PC 45 is bolted to the skid to prevent move ment during shipping To free the stove from the skid you must re move the hold down bolts in the rear of the pedestal base The rear cover panels are removed from the stove to make it easier to get at the hold down bolts The rear cover panels are packed inside the hopper and should be installed on the stove as shown It is recommended that the rear covers are installed after the unit is in place and the vent pipe is installed E Shipping Bolts These holes are Firebrick also used for Mobile Home Install the firebrick vertically on the angle above Cover Panels Installation the burnpot Fig 1 OR XL V EL A SS e SSS Ma 15 J 9 A Fig 2 4 PC 45 Corn Pellet Stove 2 Glass Ret
2. mal operation and allows the stove to be installed closest to the wall Two inches from the wall is safe however four inches allows better access to remove the rear panel The vertical portion of the vent should be three to five feet high This vertical section will provide natural draft in the event of a power failure y LL TEN K dE LN 3 ft to combustibles 2 Preferred method This method also provides excellent venting for normal operation but requires the stove to be installed farther from the wall The vertical portion of the vent should be three to five feet high and at least three inches from a combustible wall This vertical sec tion will provide natural draft in the event of a power failure If the stove is installed below grade the vent termination should be at least 1 foot above grade CAUTION Keep combustible materials such as grass leaves etc atleast 3 feet away from the flue outleton the outside of the building combustibles PC 45 Corn Pellet Stove 9 3 Installing into an existing chimney US only This method provides excellent venting for nor mal operation This method also provides natural draft in the event of a power failure If the chimney condition is questionable you may want to install a liner as in method 6 4 Installing into an existing fireplace chimney US only This method provides excellent venting for nor mal operation This
3. E yg en M M LPS 3 min TIE 3 min PL vent manufacturer s firestop spacer and support No insulation or other combustible materials are allowed within 3 Minimumflue ventconfiguration It is recommended that outside air be installed with this venting configuration of the PL vent pipe See Page 6 for T comerinstallation clearances Through the ceiling vent follow PL vent manufacturers recommendations when using wall and ceiling pass through d Fig 18 Min above ground level DO NOT INSTALL A FLUE DAMPER IN THE EXHAUST VENTING SYSTEM OF THIS UNIT DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE INSTALL VENT AT CLEARANCES SPECIFIED BY THE MANUFACTURER WARNING DO NOT INSTALL IN SLEEPING ROOM CAUTION THE STRUCTURAL INTEGRITY OF THE MOBILE HOME FLOOR WALL AND CEILING min wall to outlet ROOF MUST BE MAINTAINED CAUTION THE STOVE IS HOT WHILE IN OPERATION KEEP CHILDREN CLOTHING AND FURNITURE AWAY CONTACT MAY CAUSE 12 PC45Com Pellet Stove SKIN BURNS AUTOMATIC IGNITION OPERATION The PC45 corn pellet stove is more than just automatic ignition it is also automatic temperature control The automatic system will allow the fire size to be adjusted to match the heating needs and even put the fire out if necessary If heat is needed after the fire is out the PC 45 will automatically re ignite and adjust the fire size to match t
4. Fig 22 PC 45 Corn Pellet Stove 13 AUTOMATIC START UP Starting the Fire Igniter Switch to AUTO up position Make sure the unit is plugged into a 120 VAC 60 HZ electrical source The power light should be the only light lit Anytime there is interruption in power at the receptacle the combustion blower will run for 1 minute after the power is regained 1 Turn the Mode Selector to OFF 2 Fill the hopper with corn or pellets 3 Clean the burn pot and housing if necessary 4 f starting after an empty hopper turn the feed adjuster to TEST until the fuel is visible in the auger tube opening This also allows you to check the motors for operation NOTE The auger motor will not operate with the view door or ash door open NOTE The initial start up on a new stove may require the corn to be purged into the burnpot area before continuing to step 5 5 Turn the feed adjuster to 2 corn or 4 pellet 6 Flip the igniter switch up into the AUTO position 7 Turn the temperature dial to the desired room temperature 8 Turn the mode selector dial to Room Temperature or Stove Temperature 9 Fill the hopper with corn or pellets and remove the ashes as required Warning NEVER USE GASOLINE GASOLINE TYPE LANTERN FUEL KEROSENE CHARCOAL LIGHTER FLUID OR SIMILAR LIQUIDS TO START OR FRESHEN UP A FIRE IN THIS HEATER KEEP ALL SUCH LIQUIDS WELL AWAY FROM THE HEATER WHILE IN USE 14 45 Com Pel
5. adjustment of customer controls and customer education Labor materials expenses and or equipment needed to comply with law and or regulations set forth by any governmental agencies are not covered This Warranty provides specific legal rights and the consumer may have other rights that vary from state to state In the event of change in ownership the remaining portion of this warranty may be transferred to the new owner by sending the new owner information and a transfer fee of 25 00 US to the Harman Stove Company PLEASE READ THE LITERATURE BY THE MANUFACTURER FOR THE VARIOUS ACCESSORY DEVICES THE MANUFACTURER WARRANTS THESE ACCESSORY DEVICES NOT HARMAN STOVE COMPANY OR THEIR WARRANTY ADMINISTRATOR FURTHERMORE THESE ACCESSORY DEVICES MUST BE INSTALLED AND USED ACCORDING TO THE RECOMMENDATIONS OF THE MANUFAC TURER REMEDIES The remedies set forth herein are exclusive and the liability of seller with respect to any contract or sale or anything done in connection therewith whether in Contract in tort under any warranty or otherwise shall not except as herein expressly provided exceed the price of the equipment or part of which such liability is based CLARIFY The above represents the complete warranty which is given in connection with stoves manufactured by Harman Stove Company No other commitments verbal or otherwise shall apply except by a written addendum to this warranty
6. ash Remove the burn pot for cleaning by Lift up and remove the front plate lock amp front plate Remove the auger extension corn burnpot only Remove the burnpot grate Clean all fines and debris Reinstall in reverse order NOTE See burnpot maintenance section for amore detailed description on burnpot maintenance and cleaning PC 45 Corn Pellet Stove 19 Flue Outlet Blower Cover e e e e e I Maintenance Cleaning continued 5 Remove the ash pan 6 Remove the combustion blower cover by turning the blower cover latch vertical as shown in fig 32 Slide the cover out of the slot on the left This will expose the combustion blower wheel and flue outlet fig 35 7 Clean the blower wheel with a brush anda vacuum Fig 33 Latch closed with ig cleaner blower coverin place Burn 8 Use a brush to clean the flue being careful not to potclean outis closed damage the ESP probe The flue goes straight through into the vent pipe therefore the vent pipe can also be cleaned to some extent through the flue ESP probe outlet 9 Reinstall the blower cover and relatch 10 Slide ash pan into the stove and latch into place 1 Remove the rear shields to access the feeder Fig 35 Exposed blower Fig 36 Blower cover cover wheel and flue opening removed NOTE ESP probe is visible 2 Remove the wing nut on the feeder cover and slide the cover off the threaded rod 3 Remove all fines with a vacuum B
7. before lighting the fire 4 Something is restricting flow in the hopper or causing the slide plate to stick 5 Feed motor has failed PARTIALLY BURNED FUEL 1 Feed rate too high 2 Draft too low 3 Burn pot may need to be cleaned 4 Combination of all the above 5 6 status blink A 6 blink control board status indication is caused by poor or incomplete com bustion The circuit board has the ability to track the combustion through feed settings and ESP tem peratures When the control board has calculated poor or incomplete combustion it will shut down the unit as a safety feature Poor or incomplete combustion is a contributer of creasote which may Cause a chimney fire A 6 blink status may be caused by several things 1 Blocked or partially blocked flue 2 Blocked or partially blocked inlet air a backdraft damper on the inlet pipe may be stuck closed b if outside air is installed the inlet cover may be blocked 3 The air chamber under the burnpot may be filled with fines and small bits of ash 4 The holes in the burnpot may be getting filled with ash or carbon buildup 5 Combustion blower fan blades may need cleaned 6 There is no fuel in the hopper COMBUSTION BLOWER RUNS AFTER SHUT DOWN This is a normal function The combustion blower will run for 5 hours after the stove is completely cool SMOKE SMELL Seal the vent pipe joints and connection to stove with silicone FIRE HAS GONE OUT 1 No fuel
8. burning on low or cycling off periodically may be able to go 3 to 8 days or longer Ashes should be placed in a metal con tainer with a tight fitting lid The closed con tainer of ashes should be placed on a noncom bustible floor or on the ground well away from all combustible materials pending final disposal If ashes are disposed of by burial in soil or oth erwise locally dispersed they should be re tained in the closed container until all cinders have thoroughly cooled Fig 31 Corn Bumpot It is recommended that the stove is cold and shut down when removing ash pan 1 Pull up on the latch handle to swing the ash pan access door out and to the right 2 Use the ash pan handle to carry and dispose of ashes 3 Slide the ash pan back into the stove Cleaning If you have been burning corn the stove will need to be cleaned approximately once a month The amount of corn burned and the frequency of these cleanings will vary depending on the quality of the corn used If you have been burning pellets the stove will need to be cleaned approximately every 2 to 3 months The amount of pellets burned and the fre quency of these cleanings will vary depending on the quality of the pellets used HeatExchanger F ins 1 Shut down stove and disconnect power cord to insure that all motors are stopped 2 Clean the heat exchanger with the scraper as shown if Fig 32 3 Brush or scrape the inside walls of the stove to remove fly
9. in hopper 2 Draft setting is too low 3 Something is restricting fuel flow 4 Feed motor or draft motor has failed 5 Power failure or blown fuse PC 45 Corn Pellet Stove SMOKE IS VISIBLE COMING OUT OF VENT 1 Air fuel ratio is too rich A Feed rate too high B Draft too low caused by a gasket leak 2 Unit is in an ignition cycle LOW HEAT OUTPUT 1 Feed rate too low 2 Temperature setting too low Stove Temp Mode 3 Draft too low because of gasket leak 4 Poor quality or high moisture fuel Helpful Hints Cleaning Burn Pot Whenever your stove is not burning take the opportunity to scrape the burn pot to remove car bon buildup A vacuum cleaner is handy to remove the residue Be sure the stove is cold if you use a vacuum Carbon buildup can be scraped loose with the fire burning using the special tool provided with your stove Scrape the sides of the burnpot corn grate and the floor and sides pellet grate The carbon will be pushed out by the incoming fuel Always wear gloves to do this Removing Ashes Turn the Temp Dial to number 1 approximately 30 minutes before removing ashes This will result in a cooler stove and ash pan Maximum Feed Adjuster settings are not needed in most cases Operating in the normal range 2 corn 4 pellet is recommended when maximum heat output is not required The ESP probe prevents the stove from being over fired Keep the stove free of dust and dirt TE The
10. is connected check the draft reading again making sure all doors and windows in the home are closed If this reading is more than 05 higher than the unconnected reading check for possible restrictions or the need for outside air See page 9 Mobile Home Installation With Side Shields When installing this unit in a mobile home several requirements must be followed 1 The unit must be bolted to the floor This canbe done with 1 4 lag screws through the 2 holes in the base plate 2 The unit must also be connected for the outside air See page 8 3 Floor protection and clearances must be followed as shown 4 Unit must be grounded to the metal frame of the mobile home CAUTION This appliance must be vented to the out side Duetohighterperatures the stove shouldbe placed out of traffic andaway fromfumiture and draperies Children and adults should be alerted to the haz ards of high surface temperatures and should stay away to avoid burn to skin and or clothing Young children should be carefully supervised when they are in the same room as the stove E09 PEO ETOR Clothing and other flammable materials should not be placed on or near this unit Installation and repair of this Harman Stove should be done by a qualified service person The appliance Fig 9 Referto page 18 for should be inspected before use and at least annually by a detailed draftsettings and qualified service person More frequent cleaning will pe
11. method also provides natural draft in the event of a power failure The damper area must be sealed with a steel plate or fiberglass A cap should be installed on the chimney to keep out rain If the chimney condition is questionable you may want to install a liner all the way to the top as in method 5 10 PC45Corn Pellet Stove EE CON 5 Installing into an existing fireplace chimney US and Canada This method provides excellent venting for nor mal operation This method also provides natural draft in the event of a power failure In Canada and some places in the US it is required that the vent pipe extend all the way to the top of the chimney In this method a cap should also be installed on the chimney to keep out rain Be sure to use approved pellet vent pipe fittings Seal pipe joints with silicone in addition to the sealing system used by the manufacturer Pipe size should be increased to 4 using this method 6 Installing into an existing chimney US and Canada This method provides excellent venting for nor mal operation This method also provides natural draft in the event of a power failure In Canada and some places in the US it is re quired that the vent pipe extend all the way to the top of the chimney The pipe or liner inside the chimney should be 4 diameter In this method a cap should also be installed on the chimney to keep out rain PC 45 Corn Pellet Stove 11 SS a Sy
12. the JDEWALL STOVE 18 10 OMBUS CELUI CI S TENDANT DE amp EN AVANT DE amp DES BACKWALL STON z z d COWS ET D Y DE LA ARRIERE CEILING TO STOWE TOP m m SORTE D ECHAPPEMENT VENTLATEUR DE TYPE L OU PL E STALLE label on your stove to SELON LES INS TONS DU FABRICANT ET SELON LES CODES SELON LES INSTRUCTIONS DU FABRICANT ET SELON LES CODES LOCAUX DE LA CONST T1 OCAUX DE LA CONSTRUCTION PUISSANCE ELEC OLTES 60 HERTZ 1 SANCE ELECTRIQUE 6 HAPS 13 VOLTES en HERTZ the box below OMBLISTIBLE DE BO ULETTES COMBLS OU BIOMASSES FLOOR PROTECT EMEA COMBUSTIBLE DE 5 DWS MES 10MASSES s TALLER ET ms ER SEL aN LES NS TRUCTIONS D INSTALLATION 5 R ET UTILISER S au ET D OP RATION DE FAERK TER LE BUREAU DE LA ET D ON DE FABRIC ES RSI TER 15 E CONS RUC TION OU LE BUREAU t5 POMPIERS AU SIHET DES C QNS TRUC TIO OU LE BUREAU CES POMPIERS WET DES RESTRICTIONS ET DES INSPECTIONS DINS TALLATION DANS VOTRE w RESTRICTIONS ET DES INSPECTIONS DINS TALLATIOM DANS VOTRE D NACE VOISINAGE EXEMPTION EPA PAR 40 CFR 60534 DE METHODE 2 X ON EPA PAR 40 CFR G APPROUY E FO JUR LU 4 E Dus LES MASONS BLES APPROUN f roli T SAG GE DWE if S MNSONS NM BLES PUISSANCE ESTHEE LES PAR HEURE PUISSANCE ESTIVEE 0 LES PAR HEURE SERIAL NUMBER rp 3 5 STOVE COMPA CI NE PAS CONNECTER CET APPAREIL 2 MOUNTAIN HOUSE ROAD a UNE CHEMNEE SERVANT UN AUTRE HALIFAX 17032 APPAREIL MADE IN USA
13. ustmentprocedures required It is imperative that control compartments burn ers and circulating air passageways of the stove be kept clean Mobile home installation should be done in accordance with the Manufactured Home and Safety Standard HUD CFR 3280 Part 24 6 PC45Corm Pellet Stove 0 6 O 0 O Kan Requirements for Terminating the Venting WARNING Venting terminals must not be re cessed into a wall or siding NOTE Only PL vent pipe wall pass throughs and fire stops should be used when venting through combustible materials NOTE Always take into consideration the ef fect the prevailing wind direction or other wind cur rents will cause with flyash and or smoke when plac ing the termination In addition the following mustbe observed A The clearance above grade must be a mini mum of 18 B The clearance to a window or door that may be opened must be a minimum of 48 to the side 48 below the window door and 12 above the win dow door with outside air installed 18 C A 12 clearance to a permanently closed window is recommended to prevent condensation on the window D The vertical clearance to a ventilated soffit located above the terminal within a horizontal dis tance of 2 feet 60 cm from the center line of the terminal must be a minimum of 18 E The clearance to an unventilated soffit must be a minimum of 12 F The clearance to an outside corne
14. wall or partition of combustible construction is desired the installation shall conformto CAN CSA B 365 if in Canada Inside Comer Detail dite a B Fixed p 6 Area where terminal is not permitted PC 45 Corn Pellet Stove 7 Venting IMPORTANT NOTICE A combustion blower is used to extract the com Pellet Vent Pipe or PL Vent Pipe Must be used bustion gases from the firebox This causes nega SY VC pressure in the firebox and a positive pressure in the venting system as shown in fig 10 The longer the vent pipe and more elbows used in the system the greater the flow resistance Because of these facts we recommend using as few elbows as pos sible and 15 feet or less of vent pipe The maximum horizontal run should not exceed 48 If more than 15 feet of pipe is needed the diameter should be increased from 3 to 4 because a larger pipe causes less flow resistance Be sure to use approved pellet vent pipe wall and ceiling pass through fittings to go through combustible walls and ceilings Be sure to use a starting collar to attach the venting system to the stove The starting col lar must be sealed to the stove with high temp silicone caulking Vent Pipe Pellet venting pipe also known as PL vent is constructed of two layers with air space between the layers This air space acts as an insulator and reduces the outside surface temperature to allow a clearance
15. Air Assembly 3 Flex Pipe Pellet Grate Kit PC 45 Parts List Part Number 0 88 00248 1 10 05800 1 10 724103 1 10 724108 1 10 724107 2 00 724105 3 00 02676 2 00 724104 3 20 05238 3 20 02680 3 20 0268 1 3 20 02682 3 20 02683 3 20 00496 2 00 06468 1 2 00 06468 2 2 00 773850 3 20 00744 3 20 00906 3 20 05236 3 20 9301 3 20 40985 3 21 08639 3 21 2264 7 3 31 199110 3 31 90131101 3 20 29685 3 40 900450125 3 31 00968 3 31 00982 3 40 950133125 3 44 00409 3 44 724114 3 44 724115 3 44 06179 3 90 02676 3 20 02677 3 20 02679 1 00 08636 1 00 724300 1 10 08542 2 00 08543 1 00 724112 includes pellet burnpot grate weldment and front plate Gold Plated Door Kit Gold Ash Lip Trim Ash Door Tile Pack trim amp backer plate Tile Frame Tile Pack 1 piece 1 00 08520 4 with door kit 1 00 08618 1 00 0861 7 3 43 120601 10 choices PC 45 Corn Pellet Stove 27 HARMAN GOLD WARRANTY for corn stove 6 YEAR TRANSFERABLE LIMITED WARRANTY Residential 1 YEAR LIMITED WARRANTY Commercial ARMA GOLD WARRANTY Harman Stove Company warrants its products to be free from defects in material or workmanship in normal use and service for a period of 6 years from the date of sales invoice and for mechanical and electrical failures in normal use and service for a period of 3 years from the date of sales invoice If defective in material or workmanship during the warranty period Harman Stove Company will at
16. Installation amp Operating Manual The Harman PC 45 Corn Pellet Stove STOVE COMPANY Ce manuelest disponible en Francais sur demande SAFETY NOTICE PLEASE READ THIS ENTIRE MANUAL BEFORE YOU INSTALL AND USE YOUR NEW ROOM HEATER FAILURE TO FOLLOW INSTRUCTIONS MAY RESULT IN PROPERTY DAMAGE BODILY INJ URY OR EVEN DEATH FOR USE IN THE U S AND CANADA SUITABLE FOR INSTALLATION IN MOBILE HOMES IF THIS HARMAN STOVE IS NOT PROPERLY INSTALLE D A HOUSE FIRE MAY RESULT FOR YOUR SAFETY FOLLOW INSTALLATION DIRECTIONS CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT RESTRICTIONS AND INSTALLATION INSPECTION REQUIREMENTS IN YOUR AREA CONTACT YOUR LOCAL AUTHORITY SUCH AS MUNICIPAL BUILDING DEPARTMENT FIRE DEPARTMENT FIRE PREVENTION BUREAU ETC TO DETERMINE THE NEED FOR A PERMIT CETTE GUIDE D UTILISATION EST DISPONIBLE EN FRANCAIS CHEZ VOTRE CONCESSIONNAIRE DE HARMAN STOVE COMPANY SAVE THESE INSTRUCTIONS 2 PC 45 Corn Pellet Stove Introduction The PC 45 Corn Stove makes burning corn more convenient than ever It s special Sidewinder Burn Pot allows corn to be burned from three days up to a week without cleaning depending on the corn s moisture level and burn rate Automatic Ignition allows you to fill the hopper set your desired room temperature and walk away The PC 45 will adjust it s feed rate based on the temperatures received by the room sensor and keep your home at the set temperature T
17. LIQUIDS TO START OR FRESHEN UP FIRE IN THIS HEATER KEEPALL SUCH LIQUIDS WELL AWAY FROM THE HEATER WHILE IN USE PC 45 Corn Pellet Stove Starting the Fire Igniter Switch to MANUAL down position Make sure the unit is plugged into a 120 VAC 60 HZ electrical source The power light should be the only light lit Anytime there is interruption in power at the receptacle the combustion blower will run for 1 minute after the power is regained Buming Corn 1 Turn the Feed Adjuster to desired feed rate approximately 2 2 Turnthe Mode Selector to OFF and then to the desired mode This will reset the control and start the combustion motor 3 Turn the Temperature Dial to the desired setting 4 Clean the burnpot and housing if necessary 5 Fill the burnpot with corn up to the auger shaft Then place pellets ontop of the corn as high as the shelf area See corn burnpot shown on left 6 Add starting gel on top of the pellets stir gel into the pellets and corn for faster lighting 7 Light the starting gel with a match and close the door Operation will begin when the fire reaches the proper temperature 8 Fill the hopper with corn and remove the ashes as required Burning Pellets Optional pellet burnpot required to burn pellet fuel 1 Turn the Feed Adjuster to the desired feed rate approximately 4 2 Turn the Mode Selector to OFF and then to the desired mode This will reset the control and start the comb
18. OLOWM 30334 Go 3455344 AO NMOS raris C 3nr18 11 STD 2 SIOVINO2 ON ap AHIL NOMINOO NO 3alM JUHM ALIH AA SNOWOIKNOD 3153473774 JIM JALSIML 49 n u D S e D To U 38044 J33 31714 IC HH EN 3514 5519 9 S MOd HOSN3S 310W3H pm dee d 1 QNnOJO 51 JAIM N3349 2 Mo lt FIMO NME 1 SNOLLO3NNOO 31v W34 31vW Aes c o WYYOVIG 9NIMIM MOIS 171134 NYOS SPId NVvIABVH QqMO2O HIAANY lt 81 26 PC45Corn Pellet Stove Description Hopper Gasket 6 ft Ash Pan Assembly Burnpot Housing Weldment Burnpot Grate Weldment corn Burnpot Front Plate Weldment corn Burnpot Front Plate Lock Corn Auger Extension Ceramic Insert Plate Ceramic Insert Wiring Main Harness Neutral Harness Air Pump Ground Wire Combustion Blower Ground Wire Distribution Blower Ground Wire Right Rear Shield Left Rear Shield Arrow Scraper Thermister Probe Room Sensor Circuit Board G5236 Differential Switch 5 Single Fan Blade Combustion Blower Distribution Blower Hopper Lid Latch 3 16 Rubber Washer for Hopper Lid Power Cord Fire Brick 3 White Black Control Knob 3 Control Knob Shaft 3 Front Glass Gaskets Feeder Gasket Ceramic Insert Plate Gasket Burnpot Gasket Tailpipe Gasket Owners Manual Igniter Element Air Pump Options Hopper Extension Assembly PC 45 Corn Strainer Outside
19. PC 45 can burn corn with moisture levels up to 16 with 14 5 or less ideal Pellet fuels are put into 3 categories in terms of ash content Premium at 1 or less Standard at 3 or less and all others at 3 or more The PC 45 is capable of burning all 3 catego ries of pellets due to a patented feeder and burn pot system It should be noted however that higher ash con tent will require more frequent ash removal and may provide less BTU s per pound Normally standard and high ash pellets cost less than premium pellets and can be cost effective when burned in the PC 45 The moisture content of pellets must not exceed 8 Higher moisture wil rob BTU s and may not burn properly Feeder and Specifications Feeder Body Weldment Pusher Arm MTNG Nuts 2 1 10 02681 3 30 80252013 Differential Switch 3 20 9301 Slide Plate 1 10 08037 Slab Base T nut 3 31 23756186 Igniter Element 3 20 02677 Pillow Block Bearin Igniter Mounting Bracket 2 00 724121 3 31 3614087 Auger 3 50 00465 f Bearing Retainer 2 00 04035 Fo Ay Auger Mounting Bolts 3 30 1311812513 4 Pusher Arm Mtng Bolts 4 3 30 2252005013 Cast Cover Gasket 5 16 W ingnut 3 44 00659 3 30 8131181 Cam Block Assembly 1 10 00381 Includes Cam Bearing Cam Block Cam to Auger Bolt Pusher Arm W eldment 1 10 08535 _ Air Pump 3 20 02679 Gearmotor Assembly 1 10 00697 Cast Cover Assembly Air Pum
20. ainer Clips Supplied with the door kit 4 10 24 x 3 8 button head allen screws supplied in the door kit 1 lefthand Gasket goes toward the stove 2 glass retainer clips Gasket d i goes 1 righthand toward Fig 3 the stove 4 GLASS GASKET RETAINER CLIPS __ 4 GLASS RETAINER BOLTS Fig 4 Follow the instructions in the door kit except for the bottom glass retainers Install the special glass retainer clips to the bottom of the door There is a left and right retainer clip with a radius to match the door bottom The fiber glass rope on the clip must be facing the stove body when installed NOT FACING THE GLASS These clips are designed to direct the air wash air more evenly Assembling the door Referring to the diagram note how the various components of the door system fit together e Lay the load door face down on a soft surface Clean the glass and gold door using a nonabrasive cleaner Installthe glass gasket around the outer edge of the front face of the door glass carefully to insure proper sealing Set the glass pane gently onto the door Install the hold down clips and tighten with bolts as shown e Install door on stove with hinge pins Install door handle as shown on the diagram NOTE With the flat surface of the paw bolt to the inside of the door Turn the paw bolt in for approx 17 turns Turnthe brass elbow onto the paw bolt approx 5 turns e Align the set scr
21. an ideal place to tyrap the sensor head to sense return air tem perature Side Heat Shields Side heat shields are available to reduce the clearance to combustible materials See Fig 45 The hopper extension allows you to put more pellet fuel in the hopper and extends burn time on one load of corn The hopper extension adds 65 pounds to the existing 80 pound hopper capacity allowing you to load 145 pounds of corn at one time See Fig 46 Optional Pellet Burnpot Grate The pellet burnpot grate is required to burn pellet fuel The corn burnpot and pellet burnpot grates were designed to be interchangeable and are easily installed and removed without the use of tools Each PC 45 comes with 2 corn burnpot grates to aid in continual burning of corn in the event that the corn burnpot needs to be cleaned Please note they are both corn burnpot grates notone corn grate and one pellet grate The hopper screen corn strainer was designed to sift the corn before it is fed into the burn pot This sifting will catch unwanted materials from being burned PC 45 Corn Pellet Stove 25 ON ave ZH 09 OY SIA OC ue SLUM 009 LL MOVIS NOLLO3NNO2 OL 34 ES s an NOlISNANCS MOTS NULLS JN3 313 SOLINI 8 MOTIAA Je E 4 aS x m 9 UHM Qr f S 3IHM Nea 5 B JUHA ri Rs JUHM u D 15 z Z 2 H
22. control board setting The unit can only go to low burn and will remain there until it runs out of fuel or until more heat is needed and the feed rate in creases Feed rate adjustments and dial settings are the same as AUTO settings Igniter Switch to MANUAL Stove Temperature Mode The advantage of this mode is to allow the opera tor to have a large viewing fire without blowing extra heat into the room During operation with the temperature dial set at 5 or less the distribution fan will not operate A 5 on the temperature dial and a 5 on the feed adjuster is approximately 80 output It is not necessary to oper ate the distribution blower below this point Therefore there can be a higher feed rate a larger viewing fire without an excess of hot air blowing into the room An example of when to use the Manual Stove Tem perature Mode is if you want to watch a large fire and the room is already up to temperature The Stove Tem perature Mode allows you to have a larger fire and a lower sound level without the distribution blower NOTE During the use of this mode if you keep increasing the temperature dial setting to in crease the fire size the distribution blowerwill au tomatically come on when the ESP Temperature reaches 350 F or 81 output PC 45 Corn Pellet Stove 15 16 MANUAL START UP Warning NEVER USE GASOLINE GASOLINE TYPE LANTERN FUEL KEROSENE CHARCOAL LIGHTER FLUID OR SIMILAR
23. et Stove MANUAL IGNITION OPERATION Fig 24 Room Temperature Mode This setting will produce a room temperature of 70 degrees with the distribution blower atmedium speed lt POWER STATUS x CORN DISTRIBUTION BLOWER COMBUSTION BLOWER AUTO IGNITER MANUAL FEED MOTOR IGNITER e 85 TF WARNING HIGH VOLTAGE Disconnect power before opening cover Fig 25 This setting will produce a large viewing fire without a distribution blower operating The PC45 Corn Pellet Stove is capable of manual operation This also allows the op erator to manually control operation during an emergency i e ignitor failure when using a 502H battery backup or when using certain generators The unit can be switched between AUTO and MANUAL at any time during operation NOTE When starting the unitin the AUTO mode and switching to MANUAL the fire must be large enough to turn the ignitor light off located on the control board This is a Signal that the start cycle is completed and the fire will not go out Igniter Switch to MANUAL Room Temperature Mode The fire will have to be lit with starting gel and a match or started automatically see Automatic Op eration Turn to Manual position when the fire is es tablished The difference between AUTO Room Tempera ture Mode and Manual Room Temperature Mode is that the fire will not go out as the room temperature goes above the
24. et leakage motor operation and ignitor operation The PC 45 is then factory set at a mid point adjustment and in most cases will not need any adjustments NOTE The factory low draft setting may not be correct for the units permanentinstallation conditions The control board on the PC45 is equipped with a low draft adjustment port Located on the control face just to the right of the igniter light This voltage adjustment is provided to allow the unit to be adjusted for the household voltage where the unit is going to be in permanent operation NOTE The line voltage varies from area to area and often home to home The low draft voltage should be adjusted to achieve the most efficient burn on low burn or maintenance This voltage adjustment allows the installer to change the low voltage set point approximately 10 volts This adjustment should be done by the installer during set up because a draft meter reading is required to insure proper set up If the unit is not adjusted properly it does not cause a safety concern If the unit is adjusted too high only effiency is lost If the unit is adjusted too low the low draft pressure switch will not allow the feeder motor or the igniter to operate 18 PC45Corn Pellet Stove Draft Meter bolt hole location On a PC 45 the draft hole is under the left rear corner of the firebox Fig 30 A simple draft test should be performed after completing the flue pipe installation To record
25. ew with the flat spot on the paw and tighten e After attaching the door handle close and latch the door by turning the handle to the six o clock position Does the door rope compress If not loosen the set screw turn the paw bolt one more turn into the door Repeat as required to achieve a tight door fit NOTE Remember to thoroughly clean the glass and the gold door frame before lighting the stove for the first time PC 45 Corn Pellet Stove 5 Installation Installing Place the stove on a noncombustible floor protec tor that extends 6 inches to the front 6 inches to the sides and 1 inch to the rear of the stove The minimum floor protector material is 24 gauge sheet metal Place the stove away fromcombustible walls at least as far as shown in figures 6 7 amp 8 Please note the differ ence in side wall clearance with and without side shields Note that the clearances shown are minimum for safety but do not leave much roomfor access when clean ing or servicing Please take this into account when plac ing the stove 9 With Side Shields Connect the power cord to 120 V A C 60Hz 13 WithoutSide Shields grounded receptacle A surge protector is recommened Fig 6 to protect the circuit board Prior to installing the flue pipe connect a draft meter to the stove as shown in fig 9 The draft meter must have a minimum range of 0 0 5 Turn stove to TEST Mode and record the draft reading After the flue pipe
26. f the defect Extra costs such as mileage and overtime are not covered Nuisance calls are not covered by these warranties THIS WARRANTY IS LIMITED TO DEFECTIVE PARTS REPAIR AND OR REPLACEMENT AT HARMAN STOVE COMPANY S OPTION AND EXCLUDES ANY INCIDENTAL AND CONSEQUENTIAL DAMAGES CONNECTED THEREWITH WARRANTY EXCLUSIONS Failure due but not limited to fire lightning acts of God power failures and or surges rust corrosion and venting problems are not covered Damage and or repairs including but not limited to remote controls filters fuses knobs glass ceramic brick panels ceramic fiber afterburners door packing tile ceramic log sets paint batteries or battery back up and related duct work are not covered Also excluded from this warranty are consumable or normal wear items including but not limited to flame guides grates coal bars afterburner hoods fire brick gaskets Additional exclusions for corn stoves are burnpot housing weldment burnpot grate weldment pellet or corn burnpot front plate pellet or corn burnpot front plate lock corn auger extension ceramic insert and ceramic insert plate Additional or unusual utility bills incurred due to any malfunction or defect in equipment and the labor cost of gaining access to or removal of a unit that requires special tools or equipment are not covered Maintenance needed to keep the stove in good operating condition 15 not covered This includes but is not limited to cleaning
27. he PC 45 s automatic temperature control system eliminates the warm cold cycle associated with ther mostatically controlled heating systems and even turns the PC 45 on and off as needed Our exclusive Accordion Heat Exchanger and Air Cooled Combustion Blower allows the PC 45 to produce maximum heat without creating high exhaust temperatures The Outside Air option can increase heat efficiency even more The PC 45 can burn corn with moisture levels up to 1696 with 14 596 or less being ideal It can also burn pellets regardless of ash content This allows you to buy lower cost fuel and still achieve the same results Warnock Hersey ISTEDCORN PELLET FUEL BURNING ROOM HEATER APPAREIL DE CHAUFFAGE CATALOGUE DE Vv Vg MODEL PC 45 MODELE POUR BR LER DES MAIS agis JMBUSTIBLES TESTED TO UL 1482 INSTALL WITH MININUM e mmens rmm INSTALLER AVEC LES DIS ASTM E1500 CH MIT REMOVE THESLABEL CLEAPA ANC ES TO WALLS DES MATERIAUX COMBUSTIBLES DE core DE core TANC ES png DE SEC CURITE OREGON SHOWN DU MER DE C AU PO OELE 18 DME INDIQUE DU MOR ARRERE AU POELE 2 7 n os EF BISTALLATIOM DU PLAFOND AU DESSUS DU PO LE i a sks DU COIN DU PO LE AU MOR DIAG y Please COPY your TEST DATE MARCH 1969 PREVENR LES FEUX DE MAISONS OPERER SEULEMENT AVE LA MINMUM CLEARANCES UN WITH PORTE D OUVERTURE ET LA PORTE DES CENTRES FERMEES TO COMBUSTIBLES APPAREIL a IT ETRE PLACE SUR UM PLANCHER PRO TEC TEUR serial number from
28. he heating need The totally automatic room sensor mode is recommended because of its efficiency The unit can be switched between AUTO and MANUAL at any time during operation Igniter switch to AUTO Room Temperature Mode In Room Temp Mode heat output is controlled auto matically by the Room Sensing Probe Whenthe Room Sens ing Probe calls for heat the stove will increase output When the Room Sensing Probe is getting close to the set tempera ture the stove will begin to level off output and keep the fire burning at just the right temperature to maintain that setting High output is determined by the feed rate setting This setting generally on 2 corn or 4 pellet can be increased if higher burn rates are necessary When burning corn the feed rate setting can be ad justed anywhere within the yellow range with a 3 setting being the maximum setting 1 the lowest setting This set ting will vary depending on the quality of corn used When burning pellets the feed rate setting can be Fig 21 Room Temperature Mode This setting will produce adjusted within the full range between 1 on the low side to a room temperature of 70 degrees with the distribution blower 86 On the high side atmedium speed Overfeeding is not a safety concern but the fire may ns pushed off the burnpot and extinguish in the ash pan In Room Temp Mode a constant fuel consumption rate is sacrificed for exact room temperature Therefore a
29. hrough the hole in the spare clean front plate andplace front plate against Fig 40 Corn Burnpot the burnpot grate and housing 9 Install the front plate lock 10 The dirty auger extension burnpot grate and front plate just removed can now be cleaned for the next scheduled maintenance NOTE After cleaning of these parts inspect for excessive wear and replace as needed Cleaning of Burnpot Parts Cleaning can be performed in 2 basic ways 1 Because the slag buildup will absorb moisture from the air when cool the parts can just be left exposed for several days and the slag buildup will crumble off of the parts 2 accelerate this process the parts can be soaked in water for approximately 30 minutes depending on the amount of buildup they could be cleaned in less time NOTE Cleaning of these parts is notnecessary until you see that there is noticeable decrease in the quality of the flame in the burnpot Example Unburned fuel being pushed over the burnpot Fig 41 Optional PelletBurnpot required to burn pellet fuel PC 45 Corn Pellet Stove 21 PC 45 Trouble Shooting FEEDER DOES NOT FEED 1 No fuel in hopper 2 Firebox draft may be too low for low draft pres sure switch in feeder circuit to operate Check for closed doors loose or missing gasket on doors or hopper lid faulty pressure switch 3 Feed motor will not run until ESP senses 200 F Maybe you did not put enough pellets in the burn pot
30. ink Indicates control board self diagnostic fail poor incomplete combustion occurring for more ure This requires a manual reset 3 Blinks Indicates ESP Exhaust Sensing Probe failure This requires a manual reset 4 Blinks Can occur only in Room Temp Mode and indicates Room Sensing Probe failed or not installed If a Room Sensing Probe is then installed the sta tus light will automatically reset NOTE Unit will not start in AUTO with this status error 5 Blinks In Igniter Auto Mode Only Indicates that the unit has failed to light within the 45 minute start cycle To reset Turn Mode Selector to OFF then turn to either mode again than 50 minutes See Troubleshooting section for more details A six blink status may be set if the stove is allowed to run out of pellets To reset turn mode selector to OFF then back on to the desired mode If the unit was not out of pellets see Troubleshooting section Page 24 for more details Manual reset Disconnect power cord for a few seconds and reconnect If error still occurs call your Harman Dealer PC 45 Corn Pellet Stove 17 Low Draft Voltage Adjustment Combustion Motor Speed Control Low draft only set point The small straight screwdriver slot is plastic therefore the unit can be adjusted while in operation These units are pre tested at the factory with exactly 120 Volts A C 60 Hz They are checked and adjusted for firebox tightness gask
31. its option repair or replace the product as described below The warranty above constitutes the entire warranty with respect to Harman Stove Company products HARMAN STOVE COMPANY MAKES NO OTHER WARRANTY EXPRESSED OR IMPLIED INCLUDING ANY WARRANTY OF MERCHANTABILITY OR WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE No employee agent dealer or other person is authorized to give any warranty on behalf of Harman Stove Company This warranty does not apply if the product has been altered in any way after leaving the factory Harman Stove Company and its agents assume no liability for resultant damages of any kind arising from the use of its products In addition the manufacturer and its warranty administrator shall be held free and harmless from liability from damage to property related to the operation proper or improper of the equipment THERE ARE NO WARRANTIES WHICH EXTEND BEYOND THE DESCRIPTION ON THE FACE HEREOF THESE WARRANTIES APPLY only if the device is installed and operated as recommended in the user s manual THESE WARRANTIES WILL NOT APPLY if abuse accident improper installation negligence or use beyond rated capacity causes damage HOW TO MAKE A CLAIM Any claim under this warranty should be made to the dealer from whom this appliance was purchased Then contact is made with manufacturer giving the model and serial numbers the date of purchase your dealer s name and address plus a simple explanation of the nature o
32. l ash lip trim simply slide the trim over the ash lip and into the groove on the trim Cleaning Gold The gold plated door and gold Sunrise should never be buffed or polished Abrasive cleansers and metal polishes will remove the plating and therefore should never be used If the gold needs to be cleaned wait until the stove is completely cool then use a sponge soap and water to gently remove dirt and stains Before relighting the stove remove all soap residue and wipe dry OPTIONS Room Sensor Installation Hopper Extension Fig 44 nA The room sensor is a small temperature sensor on the end of a 60 gray wire This sensor is installed much like a standard wall thermostat Because it is so small it can be hidden along the trim of a doorway or even up the leg of a coffee table There is a remote room sensor port on the rear of the unit for easy exter nal connection Use standard 18 2 thermostat wire to extend the distance to the desired location 100 maxi mum The room sensor should be installed in the loca tion where you want to control the temperature NOTE Distances of more than 25 feet from the unit or in another room are not recommended The room sensor is essentialforthe Accentra s excellent efficiency It is recommended that the room sensor be installed evenif only installed onthe rear of the unit as a return air sensor There is an intake screen on the bottom ofthe rear sheetmetal enclosure This is
33. p Mounting Hardware Includes Motor Mount 1 10 00894 BHSCS 8 32 x 1 4 3 30 3108320252 Em ear Motor Specifications Weight 249 Ibs Blower 135 cfm Feed Rate 0 to 5 0 Ibs per hr Hopper Capacity 80 Ibs Fuel Corn amp Wood Pellets Flue Size 3 inch Outside Air Size 2 3 8 I D Fuse Rating 6 amp 23 Door Options Sunrise Gold Trim This kit includes a gold trim piece for the ash lip and a gold Sunrise piece for the door See Fig 42 Referring to the diagram page 5 note how the various components of the door system fit together Lay the load door face down on a soft surface Clean the glass thoroughly using a nonabra sive glass cleaner Install the glass gasket around the outer edge of the front face of the door glass carefully to insure proper sealing Note There are 4 tabs on the Sunrise These tabs have a step on the front side and are flush on the back side Place the Sunrise in the door so the step side is to the front Set the glass pane gently onto the door In stall the hold down clips and tighten with bolts as shown on page 5 To install ash lip trim simply slide the trim over the ash lip and into the groove on the trim 24 PC45Corn Pellet Stove A GoldDoor Door The gold door fig 43 is assembled and in Stalled the same as the door Refer to page 5 Be careful not to scratch the glass and be sure to clean the gold before starting a fire in the stove To instal
34. r is 11 from center of pipe G The clearance to an inside corner is 12 H Avent must not be installed within 3 feet 90 cm above a gas meter regulator assembly when measured fromthe horizontal center line of the regu lator O Air supply inlet Vent terminal V Closed The clearance to service regulator vent outlet must be a minimum of 6 feet J The clearance to a non mechanical air sup ply inlet to the building or the combustion air inlet to any other appliance must be a minimum of 48 K The clearance to a mechanical air supply inlet must be a minimum of 10 feet with outside air installed 6 feet L The clearance above a paved sidewalk or a paved driveway located on public property must be a minimum of 7 feet M The clearance under a veranda porch deck or balcony must be a minimum of 12 inches NOTE The clearance to vegetation and other exterior combustibles such as mulch is 36 as mea sured from the center of the outlet or cap This 36 radius continues to grade or a minimum of 7 feet below the outlet Certain Canadian andor Local codes or regu lations may require different clearances A vent shall not terminate directly above a side walk or paved driveway which is located between two single family dwellings and serves both dwell ings 3Only permitted if veranda porch deck or bal cony is fully open on a minimum of 2 sides beneath the floor NOTE Where passage through a
35. rush not Supplied Can be found in hardware stores Soot and Fly Ash The products of combustion will contain small particles of fly ash The fly ash will collect in the exhaust venting system and restrict the flow of the flue gases Incomplete combustion such as oc curs during startup shutdown or incorrect opera tion of the room heater will lead to some soot for mation which will collect in the exhaust venting sys tem The exhaust venting system should be in spected after the first month of burning to determine the frequency of cleaning that will be required NOTE Be careful notto The frequency could vary from once a month to once damage ESP probe Season depending on the quality of the fuel being when cleaning with used brush 20 PC45Corn Pellet Stove 1 Be sure the stove power is turned off 2 Lift up and remove the front plate lock and front plate Set aside the front plate 3 Remove the auger extension by pulling toward you then set aside corn burnpot only 4 Remove burnpot grate and set aside 5 Clean all fines and debris that has accumulated 6 Install the spare clean burnpot grate making sure the 2 holes line up with the 2 tabs in the burnpot housing 7 Now install the spare clean auger extension into the auger shaft Make sure there isn t any corn or debris in the shaft opening This will prevent the auger extension from being fully inserted into the shaft 8 Align the auger extension t
36. s attull Speed forone minute So hie SATO yax a Will be litin either stove CORN stove will to orroom temp mode when lp minimum burn and pointer is notwithin off DISTRIBUTION BLOWER the blowers will position band except E bis after normal shutdown 2 a Blinks to indicate errors e mindy Hrs 20 i AUTO listed below ED MOTOR are still in Test IGNITER Mode IGNITER e MANUAL Indicates power to Igniter switch distribution blower Setto appropriate Start Up mode Indicates power to combustion blower Distribution Blower speed adjustmentrange L low high Variable speed anywhere between L and H although as the stove temp goes up So does Indicates power to the feed motor Indicates igniteris om WARNING HIGH VOLTAGE mer ane roca Disconnect power before opening cover Mode Selector Temp dial Allows you to choose Allows you to adjustthe room temperature in Room Temp Mode using the outerscale marked in degrees Fahrenheit Italso allows you to adjustthe stove temperature while in Stove Temp Mode using inner scale marked from 1 to 7 between Room Temp Mode Stove Temp Mode or OFF Also allows you to vary the distribution blowerspeed by turning the knob to the high orlowside ofeach mode Dealer Diagnostic Port Fordealermaintenance use only Requires special DDM monitor supplied to Harman Dealers exclusively 6 Blinks Indicates that the control has calculated 1 Bl
37. s it gets colder more fuel will be burned automatically The distribution blower speed will vary according to the position of the mode selector pointer and fire size Igniter switch to AUTO Stove Temperature Mode This allows for automatic ignition upon start up only The unit can then be set at any desired setting The heat output and fuel consumption will remain constant regardless of room temperature This setting will produce medium heatwith the The unit s low bum or maintenance setting is as low as it de DU on one Oo ou will go It will not go out unless it runs out of fuel or is turned off Shut Down Procedure To kill the fire or stop burning the stove turn the Mode Selector to OFF This will cause the fire to diminish and burn out When the fire burns out and the stove cools down everything will stop NOTE The combustion blower motor will run for 5hours after the stove is completely cool This insures that all fuel in the burnpot and ashes located in the ash pan are completely cold before shut down ofthe combustion motor If you pull the plug to shut down the stove all motors will stop This may cause incomplete combustion and smoke in the firebox If the load door is opened the smoke may es cape This setting will produce continuous maximum heatoutput The best way to shut down the stove is simply let it run with the distribution blower at full speed out of fuel then the stove will shut down automatically
38. the results for future reference 1 Plug unit into a 120VAC 60 HZ outlet 2 Close the hopper lid front view door and the ash pan access door Neither fuel or a fire are required for this test 3 With the mode selector in the OFF position turn the feed adjuster to TEST 4 Record the high draft in W C Normal is 35 to 55 The control will be on the High Draft for a total of 2 minutes 5 After 2 minutes is up the combustion motor will go down to low draft and the distribution blower will go on high Allow approximately 15 seconds to pass for the combustion motor to slow before checking the low draft 6 If the low draft is between 25 and 35 record the reading in W C If the reading is higher slowly turn the set screw counter clockwise until the draft lowers If the reading is lower very slowly turn the set screw clockwise until the draft increases NOTE The test mode alternates from high to low draft every 60 seconds If more time is needed for draft adjustment waituntil the next low draft cycle NOTE In some cases the draft may not go as low as 25 to 35 even with the set screw completely counter clockwise This is not a problem Removing Ashes The frequency in which you will need to empty the ash pan will vary depending on the conditions that the stove has been operating in For example A stove burning on high continuously will probably need the ashes removed every 1 to 2 days whereas a stove
39. to combustibles of only 3 inches The sections of pipe lock together to form an air tight seal in most cases however in Some cases a per fect seal is not achieved For this reason and the fact that the PC45 operates with a positive vent pres Positive static pressure sure we specify that the joints also be sealed with clear silicone Outside Air j Fig 10 Negative static pressure Outside air is optional except in mobile homes and where building codes require The benefit of outside air is mainly noticed in small very tight houses To install outside air use 2 3 8 I D flex pipe part number 2 00 08543 There is abreak away hole on the rear panel which must be removed before connecting the flex pipe The pipe should be run out side and terminate 3 feet or more to the side or be low the vent pipe outlet Never terminate the outside air above the vent pipe outlet The maximum length run of this pipe is 15 feet If a longer run is needed the size must be increased to 3 Inlet cover part number 1 10 08542 should be used to keep birds rodents etc out of pipe Outside airflex pipe goes here Flex pipe part 2 00 08543 HRV InletC rt 2 di When installing in a house with a Heat Reclaim ing Ventilation System HRV be sure the system is balanced and is not creating a negative pressure in 8 45 Com Pellet Stove the house 1 Preferred method This method provides excellent venting for nor
40. ustion motor 3 Turn the Temperature Dialto the desired setting 4 Clean the burnpot and housing if necessary 5 Fillthe burnpot with pellets so that the auger tube opening is covered and slopes away from the auger tube opening See pellet burnpot shown on left 6 Add the starting gel on top of the pellets Stir the gel into the pellets for fast lighting 7 Light the starting gel with a match and close the door Operation will begin when the fire reaches the proper temperature 8 Fill the hopper with pellets and remove the ashes as required Shut Down Procedure To kill the fire or stop burning the stove turn the Mode Selector to OFF This will cause the fire to diminish and burn out When the fire burns out and the stove cools down every thing will stop NOTE The combustion blower motor will run for 5 hours after the stove is completely cool This in sures that all fuel in the burnpot and ashes located in the ash pan are completely cold before shut down of the combustion motor If you pull the plug to shut down the stove all motors will stop This may cause incomplete combustion and smoke in the firebox If the load dooris opened the smoke may escape The best way to shut down the stove is simply let it run out of fuel then the stove will shut down automatically AUTOMATIC IGNITION ESP CONTROL Power Light eed adjuster Indicates power to the Sets the maximum control feed rate Test POWER Runs all motor