Harman Stove Company P61 Stove User Manual
Contents
1. s a a MME A a O dt ux i i Ben MVHOVIO OMIM AALS 137139 Lod NINTH 20 Door Options e md DI 7 y Door Frame J Y j Ash Lip Trim Ash Door Tile Frame Optional The door trim kit includes the door frame the ash lip trim and the ash door tile frame Available in brushed stainless gold or bright nickel they add a beautiful accent to your stove To install lay the frame face down on a soft surface Drill the four holes in the door using the bit provided You ll see there are dimples in the cast iron showing where to drill Fasten the door frame by inserting the 4 threaded posts on the frame through the door The posts should line up with the 4 holes located at the corners of the door Once the posts are through the door fasten frame with 4 nuts and tighten until the frame is snug To install ash lip trim simply slide the trim over the ash lip and into the groove on the trim The ash door tile frame can be used with or without the optional decorative tile Slide the spring clip into the channel on one end of the frame Place the frame into the recessed area on the door inserting the clip end first The tension of the spring holds the frame in place 21 Brushed Stainless Cutout Tile Plate Decorative Tile Decorative tile is available in several designs The tile installs behind the trim on the ash door Along with the above pictured
2. Ny SD t go ome 30d tnit er nd RR E m 9 5 mean 2100 Xs O EY b um liM ms IENYERIERERDA vm ms OL erra N a dee Ee a 3 sala via bad THODA Thid ep hnl it hi aL EE ia 30 Wd H31Y3H ROSY ONINTS LITE Ga Table of Contents Testing Label Assembly amp Installation Venting Operation ESP Control Maintenance Trouble Shooting Feeder Parts Specifications Wiring Diagram Options Parts List Warranty Please read this entire manual before you install and use your new room heater Failure to follow instructions may result in property damage bodily injury or even death SUITABLE FOR MOBILE HOME INSTALLATIONS SAVE THESE INSTRUCTIONS Harman Home Heating 352 Mountain House Road Halifax PA 17032 3 Assembly Installation Unpacking The P61 is bolted to the skid to prevent movement during shipping To free the stove from the skid you must remove the hold down bolts in the rear of the pedestal base Removing or Installing rear cover panels To remove the rear cover panels loosen the screws slightly and slide the covers outward as shown in the illustration To reinstall simply slide back into place and retighten the screws Firebrick Install the firebrick vertically on the angle above the burnpot Flame Guide Install the cast iro
3. CAUTION This appliance must be vented to the outside Due to high temperatures the stove should be placed out of traffic and away from furniture and draperies Children and adults should be alerted to the hazards of high surface temperatures and should stay away to avoid burn to skin and or clothing Young children should be carefully supervised when they are in the same room as the stove Clothing and other flammable materials should not be placed on or near this unit Installation and repair of this Harman Stove should be done by a qualified service person The appliance should be inspected before use and at least annually by a qualified service person More frequent cleaning will be required It is imperative that control compartments burners and circulating air passageways of the stove be kept clean 9 13 Fig 4 18 Mobile home installation should be done accordance with the Manufactured Home and Safety Standard HUD CFR 3280 Part 24 Fig 5 Requirements for Terminating the Venting WARNING Venting terminals must not be recessed into a wall or siding NOTE Only pellet vent pipe wall pass throughs and fire stops should be used when venting through combustible materials NOTE Always take into consideration the effect the prevailing wind direction or other wind currents will cause with flyash and or smoke when placing the termination In addition the following must be observed
4. A The clearance above grade must be a minimum of 18 1 B The clearance to a window or door that may be opened must be a minimum of 48 1 with outside air installed 18 C A 12 clearance to a permanently closed window is recommended to prevent condensation on the window D The vertical clearance to a ventilated soffit located above the terminal within a horizontal distance of 2 feet 60 cm from the center line of the terminal must be a minimum of 18 E The clearance to an unventilated soffit must be a minimum of 12 F The clearance to an outside corner is 11 from center of pipe G The clearance to an inside corner is 12 H A vent must not be installed within 3 feet 90 cm above a meter regulator assembly when measured from the horizontal center line of the regulator The clearance to service regulator vent outlet must be a minimum of 6 feet J The clearance to a non mechanical air supply inlet to the building or the combustion air inlet to any other appliance must be a minimum of 48 1 K The clearance to a mechanical air supply inlet must be a minimum of 10 feet with outside air installed 6 feet L The clearance above a paved sidewalk or a paved driveway located on public property must be a minimum of 7 feet M The clearance under a veranda porch deck or balcony must be a minimum of 12 inches see B NOTE The clearance to vegetation and other exterior combustibles such as mulch is 3
5. a minimum 84 value Floor protection must extend 6 inches to the front 6 inches to the sides and 1 inch to the rear of the stove Place the stove away from combustible walls at least as far as shown in figures 3 4 and 5 Please note the w difference in side wall clearance with and without side shields Note that the clearances shown are minimum for safety but do not leave much room for access when cleaning 209 13 _ or servicing Please take this into account when placing the stove Connect the power cord to a 120 V A C 60Hz grounded receptacle After connecting the flue system perform the second draft 9 With Side Shields test However prior to taking the draft reading be sure all 13 Without Side Shields Fig 3 doors and windows in the home are closed Record the draft reading If this reading is more than 05 lower than the unconnected reading check for possible restrictions or the need for outside air see page 7 Mobile Home Installation When installing this unit in a mobile home several requirements must be followed 1 The unit must be bolted to the floor This can be done with 1 4 lag screws through the 2 holes in the base plate 2 The unit must also be connected for the outside air See page 7 3 Floor protection and clearances must be followed as shown 4 Unit must be grounded to the metal frame of the mobile home 5 The stove may not be installed in a room designated Floor Protector for sleeping
6. minutes the stove will go to minimum burn and the blowers will alternate from high to low every two minutes to remind you that you are still in Test Mode Distribution Blower speed adjustment range i WARNING HIGH VOLTAGE Big onnect power before opening cover Temp dial Allows you to adjust the Room temperature in Room Temp Mode using the outer scale marked in degrees Fahrenheit It also allows you to adjust the stove temperature while in Stove Temp Mode using the inner scale marked from 1 to 7 STATUS LIGHT ERROR MESSAGES 1 Blink Indicates control board self diagnostic failure This requires a manual reset 3 Blinks Indicates ESP Exhaust Sensing Probe failure This requires a manual reset 4 Blinks Can occur only in Room Temp Mode and indicates Room Sensing Probe failed or not installed If a Room Sensing Probe is then installed the status light will automatically reset Mode Selector Allows you to choose between Room Temp Mode Stove Temp Mode or OFF Also allows you to vary the distribution blower speed by turning the knob to the high or low side of each mode 6 Blinks Indicates that the control has calculated poor or incomplete combustion occurring for more than 50 minutes See Troubleshooting section for more details Manual reset disconnect power cord for a few seconds and reconnect If error still occurs call your Dealer Room Sensor and Rear Shield Installation Room Sensor Inst
7. 6 as measured from the center of the outlet or cap This 36 radius continues to grade or a minimum of 7 feet below the outlet Certain Canadian and or Local codes or regulations may require different clearances A vent shall not terminate directly above a side walk or paved driveway which is located between two single family dwellings and serves both dwellings 3Only permitted if veranda porch deck or balcony is fully open on a minimum of 2 sides beneath the floor NOTE Where passage through a wall or partition of combustible construction is desired the installation shall conform to CAN CSA B365 if in Canada Le F de Ares where terminal in no CURE Fig 6 IMPORTANT NOTICE Pellet Vent L or PL Vent Pipe Must be used Positive static pressure Negative static pressure Fig 7 Outside air flex pipe goes here Flex pipe part 1 00 08543 25 ft Inlet Cover part 1 10 08542 The Harman Direct Vent Wall Passthrough allows the proper protection of the wall and brings outside air to the stove with one component Part 1 00 677077 is all you need fits only 3 pellet pipe Acombustion blower is used to extract the combustion gases from the firebox This causes a negative pressure in the firebox and a positive pressure in the venting system as shown in fig 6 The longer the vent pipe and more elbows used in th
8. Installation amp Operating Manual P61 Pellet Stove Owners Manual We moga ba Gui Meath poimi bi e rime and seneped vy professionals who ae A cerblad im the US by fe Fireplace J ings m HI lt n Seni ah Ce manuel est disponible en Fran ais sur demande SAFETY NOTICE PLEASE READ THIS ENTIRE MANUAL BEFORE YOU INSTALL AND USE YOUR NEW ROOM HEATER FAILURE TO FOLLOW INSTRUCTIONS MAY RESULT IN PROPERTY DAMAGE BODILY INJURY OR EVEN DEATH 1 ia FOR USE IN THE U S AND CANADA SUITABLE FOR INSTALLATION IN MOBILE HOMES IF THIS HARMAN STOVE IS NOT PROPERLY INSTALLED A HOUSE FIRE MAY RESULT FOR YOUR SAFETY FOLLOW INSTALLATION DIRECTIONS CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT RESTRICTIONS AND INSTALLATION INSPECTION REQUIREMENTS IN YOUR AREA CONTACT YOUR LOCAL AUTHORITY SUCH AS MUNICIPAL BUILDING DEPARTMENT FIRE DEPARTMENT FIRE PREVENTION BUREAU ETC TO DETERMINE THE NEED FOR A PERMIT CETTE GUIDE D UTILISATION EST DISPONIBLE EN FRANCAIS CHEZ VOTRE CONCESSIONNAIRE DE HARMAN HOME HEATING SAVE THESE INSTRUCTIONS 3 90 05810 wp RO Sj 9 5 le En 90 10 13 Ado Jo Sk B2 IMYAN 9 X PALES Tad quu 2 SHINS Ti 13 eit ende i gt N 99e de My 0 Sve ARGS BUD SHON X734 T NIA d HON ALT HAL
9. allation Rear Shields Fig 22 The room sensor is a small temperature sensor on the end of a 60 wire This sensor is installed much like a standard wall thermostat Because it is so small it can be hidden along the trim of a doorway or even up the leg of a coffee table There is a remote room sensor port on the rear of the unit for easy external connection Use standard 18 2 thermostat wire to extend the distance to the desired location 100 maximum The room sensor should be installed in the location where you want to control the temperature NOTE Distances of more than 25 feet from the unit or in another room are not recommended The room sensor is essential for the P61 s excellent efficiency NOTE It is recommended that the room sensor be installed even if only installed on the rear of the unit as a return air sensor 5 16 Hex 5 16 Hex Head Head Screws Screws 2 on 2 on each each side side p Fig 23 The rear insulated shields are split in the middle for easy removal Each shield has two 5 16 hex head screws that only need to be loosened NOT REMOVED to allow the shield to slide away from the unit NOTE It is not recommended that the unit be operated with the shields removed due to the hot and moving parts which they protect Maintenance Fig 24 Combustion Blower Cover Blower Cover Latch Heat Exchanger Fins Flue Outlet Blower Cover Latch Blower Whee
10. cut out tile plate there are ten different picture tiles and four slate tiles available See your dealer for choices Cleaning Plated Trim Gold or nickel plated hardware should never be buffed or polished Abrasive cleansers and metal polishes will remove the plating and therefore should never be used If the plating needs to be cleaned wait until the stove is completely cool then use a sponge soap and water to gently remove dirt and stains Before relighting the stove remove all soap residue and wipe dry OPTIONS Side Heat Shields Side heat shields are available to reduce the clearance to combustible materials Hopper Extension The hopper extension allows you to put more pellet fuel in the hopper and extends the burn time on one load of pellets The hopper extension adds 60 pounds to the existing 72 pound hopper capacity allowing you to load 132 pounds of pellets at one time 22 HARMAN GOLD WARRANTY 6 YEAR TRANSFERABLE LIMITED WARRANTY Residential 1 YEAR LIMITED WARRANTY Commercial Harman Gold Warranty TIAR Harman Home Heating warrants its products to be free from defects in material workmanship in normal use and service for a period of 6 years from the date of sales invoice and for mechanical and electrical failures in normal use and service for a period of 3 years from the date of sales invoice If defective in material or workmanship during the warranty period Harman Home Heati
11. d also provides natural draft in the event of a power failure Some places in the US and Canada it is required that the vent pipe extend all the way to the top of the chimney The pipe or liner inside the chimney should be 4 diameter In this method a cap should also be installed on the chimney to keep out rain Venting 8 Installing through the ceiling vent EC Through the ceiling vent follow the vent manufacturers in im recommendations when using wall and ceiling pass M throughs icu d Mori oe MEI fX Minimum flue vent M configuration L Lacum Itis recommended that outside a nu air be installed with this venting ii configuration FL vent EREY Insulation d awmleg sparer Lei af he Fl E E 5 See Page 9 for d corner installation S clearances 23 JL E aes i Fig 15 Fig 14 DO NOT INSTALL A FLUE DAMPER IN THE EXHAUST VENTING SYSTEM OF THIS UNIT DO NOT CONNECT THIS UNIT TO ACHIMNEY FLUE SERVING ANOTHER APPLIANCE INSTALL VENT AT CLEARANCES SPECIFIED BY min wall to outlet THE MANUFACTURER CAUTION LM THE STRUCTURAL INTEGRITY OF THE MOBILE e S HOME FLOOR WALL AND CEILING ROOF Magn MUST BE MAINTAINED t CAUTION THE STOVE IS HOT WHILE IN OPERATION Fig 16 KEEP CHILDREN CLOTHING AND FURNITURE AWAY CONTACT MAY CAUSE SKIN BURNS MANUAL START UP Fig 20 Operation Starting First F
12. djusted so there is about one inch of ash in front of the fire fig 20 This is a maximum burn position and the stove may not achieve this position under normal burn rates NEVER USE GASOLINE GASOLINE TYPE LANTERN FUEL KEROSENE CHARCOAL LIGHTER FLUID OR SIMILAR LIQUIDS TO START OR FRESHEN UP A FIRE IN THIS HEATER KEEP ALL SUCH LIQUIDS WELL AWAY FROM THE HEATER WHILE IN USE MANUAL IGNITION OPERATION When to use Stove Temp Mode In Stove Temp Mode the Stove Temp Dial determines the temperature of the stove Heat output and fuel consumption will remain constant This makes it possible to tell how long a hopper full of pellets will last The distribution blower speed will vary according to the position of the mode selector fig 21 When to use Room Temp Mode In Room Temp Mode heat output is controlled automatically by the Room Sensing Probe When the Room Sensing Probe calls for heat the stove will increase output When the Room Sensing Probe is getting close to the set temperature the stove will begin to level off output and keep the fire burning at just the right temperature to maintain that setting High output is determined by the feed rate The maximum feed rate should be set for 1 of ash in front of fire In Room Temp Mode fuel consumption is sacrificed This setting will produce medium heat with the distribution for exact room temperature Therefore as it gets colder blower on low more
13. djustment of customer controls and customer education Labor materials expenses and or equipment needed to comply with law and or regulations set forth by any governmental agencies are not covered This Warranty provides specific legal rights and the consumer may have other rights that vary from state to state In the event of change in ownership the remaining portion of this warranty may be transferred to the new owner by sending the new owner information to Harman Home Heating PLEASE READ THE LITERATURE BY THE MANUFACTURER FOR THE VARIOUS ACCESSORY DEVICES THE MANUFACTURER WARRANTS THESE ACCESSORY DEVICES NOT HARMAN HOME HEATING OR THEIR WARRANTY ADMINISTRATOR FURTHERMORE THESE ACCESSORY DEVICES MUST BE INSTALLED AND USED ACCORDING TO THE RECOMMENDATIONS OF THE MANUFACTURER REMEDIES The remedies set forth herein are exclusive and the liability of seller with respect to any contract or sale or anything done in connection therewith whether in Contract in tort under any warranty or otherwise shall not except as herein expressly provided exceed the price of the equipment or part of which such liability is based CLARIFY The above represents the complete warranty which is given in connection with stoves manufactured by Harman Home Heating No other commitments verbal or otherwise shall apply except by a written addendum to this warranty 23
14. e burnpot with the flat end of the provided scraper Fig 31 11 Slide the ash pan into stove and re latch the ash pan door Brush not supplied Can be found in hardware stores Fig 30 Soot and Fly Ash The products of combustion will contain small particles of fly ash The fly ash will collect in the exhaust venting system and restrict the flow of the flue gases Incomplete combustion such as occurs during startup shutdown or incorrect operation of the room heater will lead to some soot formation which will collect in the exhaust venting system The exhaust venting system should be inspected at least once every year to determine if cleaning is necessary Fig 31 Trouble Shooting FEEDER DOES NOT FEED 1 No pellets in hopper 2 Feed motor will not run until ESP senses 165 deg F Maybe you did not put enough pellets in the burn pot before lighting the fire 3 Feed motor has failed 4 Something is restricting flow in the hopper or causing the slide plate to stick Firebox draft may be too low for low draft pressure switch in feeder circuit to operate Check for closed doors loose or missing gasket on doors or hopper lid faulty pressure switch PARTIALLY BURNED PELLETS 1 Feed rate too high 2 Draft too low Check burn pot clean out slide and door gasket 3 Burn pot or heat exchanger fins may need to be cleaned 4 Combination of all of the above SMOKE SMELL Seal the vent pip
15. e joints and connection to stove with high temp silicone FIRE HAS GONE OUT 1 No pellets in hopper 2 Feed rate too low 3 Something is restricting fuel flow 4 Feed motor or draft motor has failed 5 Power failure or blown fuse SMOKE IS VISIBLE COMING OUT OF VENT 1 Air fuel ratio is too rich A Feed rate too high B Draft too low caused by a gasket leak LOW HEAT OUTPUT 1 Feed rate too low 2 Draft too low because of gasket leak 3 Poor quality or damp pellets 4 Combination of 1 and 2 Helpful Hints Cleaning Burn Pot Whenever your stove is not burning take the opportunity to scrape the burn pot to remove carbon buildup A vacuum cleaner is handy to remove the residue Be sure the stove is cold if you use a vacuum Carbon buildup can be scraped loose with the fire burning using the special tool provided with your stove Scrape the floor and sides of the burn pot The carbon will be pushed out by the incoming fuel Always wear gloves to do this Removing Ashes Turn the Temperature Dial to minimum approximately 30 minutes before removing ashes This will result in a cooler stove and ash pan Maximum feed settings are not needed in most cases Operating in the normal range is recommended when maximum heat output is not required The ESP probe prevents the stove from being over fired Keep the stove free of dust and dirt Pellet fuels are put into 3 categories in terms of ash content Premium a
16. e removed before connecting the flex pipe The pipe should be run outside and terminate to the side or below the vent pipe outlet so the flue outlet is more than 12 from the inlet cover The maximum length run of this pipe is 15 feet If a longer run is needed the size must be increased to 3 Inlet cover part number 1 10 08542 should be used to keep birds rodents etc out of the pipe HRV When installing in a house with a Heat Reclaiming Ventilation System HRV be sure the system is balanced and is not creating a negative pressure in the house Fig 9 3 ft to combustibles 3 ft to combustibles 1 Preferred method This method provides excellent venting for normal operation and allows the stove to be installed closest to the wall Two inches from the wall is safe however four inches allows better access to remove the rear panel The vertical portion of the vent should be three to five feet high This vertical section will provide natural draft in the event of a power failure 2 Preferred method This method also provides excellent venting for normal operation but requires the stove to be installed farther from the wall The vertical portion of the vent should be three to five feet high and at least three inches from a combustible wall This vertical section will provide natural draft in the event of a power failure Fig 11 4 Installing into an existing chimney This method provid
17. e system the greater the flow resistance Because of these facts we recommend using as few elbows as possible and 15 feet or less of vent pipe The maximum horizontal run should not exceed 48 If more than 15 feet of pipe is needed the diameter should be increased from 3 to 4 because a larger pipe causes less flow resistance Be sure to use approved pellet vent pipe wall and ceiling pass through fittings to go through combustible walls and ceilings Be sure to use a starting collar to attach the venting system to the stove The starting collar must be sealed to the stove with high temp silicone caulking Vent Pipe Pellet vent pipe known as type L or PL vent is constructed of two layers with air space between the layers This air space acts as an insulator and reduces the outside surface temperature to allow a clearance to combustibles of only 3 inches The sections of pipe lock together to form an air tight seal in most cases however in some cases a perfect seal is not achieved For this reason and the fact that the P61 operates with a positive vent pressure we specify that the joints also be sealed with high temp silicone Outside Air Outside air is optional except in mobile homes and where building codes require The benefit of outside air is mainly noticed in small very tight houses To install outside air use 2 3 8 1 0 flex pipe part number 1 00 08543 25 ft There is a break away hole on the rear panel which must b
18. es excellent venting for normal operation This method also provides natural draft in the event of a power failure If the chimney condition is questionable you may want to install a liner as in method 7 Check with your local codes to be sure a liner is not mandatory 5 Installing into an existing fireplace chimney This method provides excellent venting for normal operation This method also provides natural draft in the event of a power failure The damper area must be sealed with a steel plate or fiberglass A cap should be installed on the chimney to keep out rain If the chimney condition is questionable you may want to install a liner all the way to the top as in method 6 Check with your local codes to be sure a liner is not mandatory 6 Installing into an existing fireplace chimney This method provides excellent venting for normal operation This method also provides natural draft in the event of a power failure Some places in the US and Canada it is required that the vent pipe extend all the way to the top of the chimney In this method a cap should also be installed on the chimney to keep out rain Be sure to use approved pellet vent pipe fittings Seal pipe joints with silicone in addition to the sealing system used by the manufacturer Pipe size should be increased to 4 using this method 7 Installing into an existing chimney This method provides excellent venting for normal operation This metho
19. f the defect Extra costs such as mileage and overtime are not covered Nuisance calls are not covered by these warranties THIS WARRANTY IS LIMITED TO DEFECTIVE PARTS REPAIR AND OR REPLACEMENT AT HARMAN HOME HEATING S OPTION AND EXCLUDES ANY INCIDENTAL AND CONSEQUENTIAL DAMAGES CONNECTED THEREWITH WARRANTY EXCLUSIONS Failure due but not limited to fire lightning acts of God power failures and or surges rust corrosion and venting problems are not covered Damage and or repairs including but not limited to remote controls filters fuses knobs glass ceramic brick panels ceramic fiber afterburners door packing tile ceramic log sets paint batteries or battery back up and related duct work are not covered Also excluded from this warranty are consumable or normal wear items including but not limited to flame guides grates coal bars afterburner hoods fire brick gaskets Additional exclusions for corn stoves are burnpot housing weldment burnpot grate weldment pellet or corn burnpot front plate pellet or corn burnpot front plate lock corn auger extension ceramic insert and ceramic insert plate Additional or unusual utility bills incurred due to any malfunction or defect in equipment and the labor cost of gaining access to or removal of a unit that requires special tools or equipment are not covered Maintenance needed to keep the stove in good operating condition is not covered This includes but is not limited to cleaning a
20. ire Be sure the power cord is plugged into a 120 volt receptacle This can be verified by the red power light on the control panel Be sure there is no fuel or other combustibles in the ash pan prior to lighting Fill the hopper with pellets Fill the burn pot with pellets to a level just short of overflowing fig 17 Adjust feed rate If this is your first fire or you are trying different pellets set the feed adjuster to 4 fig 18 This is a conservative number and will probably need to be increased After you know a feed rate setting that works well use that setting Remember too high of a feed rate will waste fuel Turn Mode selector to OFF and then to Stove Temp This will turn the combustion blower to high When starting a fire always turn the mode selector to OFF before selecting the desired mode This resets the control for start up Turn Temp Dial to 7 This will allow the stove to burn at maximum for feed rate adjusting purposes Apply starting gel to pellets in burn pot and light the gel Close the door after lighting At this point the distribution and combustion lights will be on and the feed motor light will be off As the temperature of the fire increases the feed motor light will come on and pellets will feed into the burn pot As the stove temperature increases the distribution blower speed will increase After 30 to 45 minutes it may be necessary to readjust the feed rate The feed rate should be a
21. l Fig 25 The draft pressure switch senses the pressure the hopper Note the location of this fitting known as the muffler Depending on the amount of fines in the fuel this muffler may need to be cleaned periodically Use caution when cleaning oremptying the hopper Ez Removing Ashes When approximately 1 ton of pellets has been burned it will be necessary to empty the ash pan Ashes should be placed in a metal container with a tight fitting lid The closed container of ashes should be placed on a noncombustible floor or on the ground well away from all combustible materials pending final disposal If ashes are disposed of by burial in soil or otherwise locally dispersed they should be retained in the closed container until all cinders have thoroughly cooled It is recommended that the stove is cold and shut down when removing the ash pan 1 Pull on latch handle to open the ash door and remove ash pan 2 Close the ash door while dumping ashes Use ash pan handle to carry and dispose of ashes 3 Return the ash pan into the stove and latch the ash door securely Cleaning Scrape the burn pot surface regularly Whenever adding fuel it is a good time to scrape the burn pot Using the flat end of the scraper tool scrape under the fire to remove any carbon deposits which may be forming The more frequent the scraping the better performanc you ll have The stove will need to be cleaned for appro
22. n flame guide on top of the burnpot and make sure it is fully seated against the auger opening The bottom of the flame guide is marked 38 Draft Test Procedure Before attaching any vent pipe to the stove perform a draft test for later comparison Remove the plug bolt on the underside of the firebox as shown Using the hole from the bolt attach a draft meter that is capable of reading at least 5 inches of water column W C You are going to want the meter reading negative pressure Turn the feed adjuster to Test For the first minute everything will run Record the high draft reading After the first minute the distribution blower will go to a low speed Then after the second minute two minutes after turning to test the distribution blower will come back up to high and the combustion blower will drop to low During this time record the low draft Perform the test again after the venting is complete Compare your readings If there is more than a 05 difference you have too much restriction in the venting There is no adjustment for the draft other than improving the venting configuration Leaving the stove in test will continue to cycle the blowers each minute Record your final draft redings here High and Low Shipping Bolts These holes are also used for Rear Cover Panels Mobile Home Installation Installation Installing Place the stove on a non combustible floor or a floor protector providing
23. ng will at its option repair or replace the product as described below The warranty above constitutes the entire warranty with respect to Harman Home Heating products HARMAN HOME HEATING MAKES NO OTHER WARRANTY EXPRESSED OR IMPLIED INCLUDING ANY WARRANTY OF MERCHANTABILITY OR WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE No employee agent dealer or other person is authorized to give any warranty on behalf of Harman Home Heating This warranty does not apply the product has been altered in any way after leaving the factory Harman Home Heating and its agents assume no liability for resultant damages of any kind arising from the use of its products In addition the manufacturer and its warranty administrator shall be held free and harmless from liability from damage to property related to the operation proper or improper of the equipment THERE ARE NO WARRANTIES WHICH EXTEND BEYOND THE DESCRIPTION ON THE FACE HEREOF THESE WARRANTIES APPLY only if the device is installed and operated as recommended in the user s manual THESE WARRANTIES WILL NOT APPLY if abuse accident improper installation negligence or use beyond rated capacity causes damage HOW TO MAKE A CLAIM Any claim under this warranty should be made to the dealer from whom this appliance was purchased Then contact is made with manufacturer giving the model and serial numbers the date of purchase your dealer s name and address plus a simple explanation of the nature o
24. pellets will be burned automatically The distribution blower speed will vary according to the position of the mode selector fig 21 Shut Down Procedure To kill the fire or stop burning the stove turn the Mode Selector to OFF This will cause the fire to diminish and burn out When the fire burns out and the stove cools down everything will stop Never pull the plug to shut down the stove all motors will stop This will cause incomplete combustion and smoke in the firebox If the load door is opened the This setting will produce a room temperature of 70 smoke will escape degrees with the distribution blower at medium speed The best way to shut down the stove is to simply let it run out of pellets then the stove will shut down automatically This setting will produce continuous maximum heat output with the distribution blower at full speed ESP CONTROL POWER Power Light Indicates power to the control STATUS Status Light DISTEYAUTION Will be lit in either stove or room temp mode when pointer is not within off position band except after normal shut down Blinks to indicate errors listed below COMBUSTMIN i Indicates power to distribution blower Indicates Power to combustion blower Indicates Power to the feed motor GO BLOWER HL OWER MOTOR Feed adjuster Sets the maximum feed late Test Runs all motors at full speed for two minutes to check operation After two
25. t 1 or less Standard at 3 or less and all others at 396 or more The P61 is capable of burning all 3 categories of pellets due to a patented feeder and burn pot system It should be noted however that higher ash content will require more frequent ash removal and may provide less BTU s per Ib Normally standard and high ash pellets cost less than premium pellets and can be cost effec tive when burned in the P61 The moisture content must not exceed 896 Higher moisture will rob BTU s and may not burn properly 5 250 Weight Blower Feed Rate Hopper Capacity Fuel Flue Size Outside Air Size On Board Fuse Specifications 249 Ibs 135 cfm 75 to 7 5 Ibs per hr 72 Ibs Wood Pellets 3 inch 2 3 8 in Inside diameter 6 amp 29 5 SUE CDM fH 09 OY SLA OE SIIvM 09 LL HONTE 01 qiu m ERE 4 ma HOLO NOLBDBHHO2 ADT Alda E Aldia x SHA q SHA a 3M th P JHA RON LIAL TTA ae GOMA 2423 Hd 5 cot cun n 5 gaama HOMES 3arnssad MOT gt z j aw L WIND LI ea MONACO NO 3HW amp E O NOUNS TAI TTR E tus m 451 5 a Tee EN ite Et u INO Su AL N3389 453 E 23737 5 Ena 55719 9 PLD BOSNIS MONN gt INTO Ei XH HASUD Ec au wl A ges
26. ximately every 2 to 5 tons of pellets burned The amount of pellets burned before cleaning will vary depending on the brand of pellets 1 Shut down the stove and disconnect the power cord to insure that all motors are stopped 2 Remove ash pan as described earlier 3 Remove combustion blower cover by turning the latch vertical as shown in Fig 26 and sliding the cover out of the slot on the left Fig 27 This will expose the combustion blower wheel and flue outlet Fig 24 Clean the blower wheel with a brush and a vacuum cleaner 5 Use a brush Fig 30 to clean the flue being careful not to damage the ESP probe The flue goes straight through into the vent pipe Fig 29 therefore the vent pipe can also be cleaned to some extent through the flue outlet 6 Reinstall the blower cover and relatch Maintenance 7 Open the burn pot slide as shown clean with vacuum and close Fig 27 Latch open with blower cover partly removed Burn pot clean out is open Fig 26 Latch closed with blower cover in place Burn pot clean out is closed ESP probe Fig 28 Exposed blower wheel and flue opening NOTE Blower cover ESP probe is visible removed ESP Probe Be careful not to damage ESP probe when cleaning with brush Fig 29 8 Clean the heat exchanger with the scraper as shown in Fig 25 9 Brush or scrape the inside of the stove to remove fly ash 10 Scrape th