Home
Generac 1654-0 Portable Generator User Manual
Contents
1. G E N E RAC by lt Briggs Stratton Portable Products POWER PRODUCTS 5582100 RATED HEAVY DUTY GENERATOR Owner s Manual Manual del Propietario Parts Included Piezas Incluidas Generator Generador Wheel Kit Juego de Llantas Locking 30 Amp Plug Tapone de Fijaci n Engine Oil Aceite para Motor Owner s Manual Manual del Propietario Engine Manual Manual del Motor f any parts are missing or damaged call 1 800 270 1408 Si alguna de las partes no est presente o est da ada llame 1 800 270 1408 Table of Contents Tabla de Contenidos Safety Rules Reglas De Seguridad Assembly Ensamblaje Know Your Generator Conozca Su Generador Operation Funcionamiento Product Specifications Especificaciones Del Producto 10 28 Maintenance Mantenimiento Storage Almacenamiento Troubleshooting Diagnosticos De Aver as Schematic Esquem tico Wiring Diagram Digrama El ctrico Replacement Parts Piezas De Recambio Notes Notas Questions Help is just a moment away Preguntas La ayuda es justa un momento lejos Call Generac Generator Helpline 1 800 270 1408 M F 8 5 CT Llamada Generador Helpline De Generac 1 800 270 1408 M F 8 5 CT Web www generac portables com or www briggsandstratton com Model No 1654 0 5 500 Watt AC Generator Manual 18982865 Revision 02 05 2002 GENERAC 5500 Watt Heavy Duty Generator ortable Products
2. Install Wheel Kit Hex Nut H Handle Assembly Use existing hardware to attach left side of support leg to unit Vibration Mount Flat Washer Screw CARTON CONTENTS Check all contents If any parts are missing or damaged call the generator helpline at 1 800 270 1408 The generator Generator and engine owner s manuals Locking 30 Amp plug Engine oil Wheel kit INSTALL WHEEL KIT The wheel kit is designed to greatly improve the portability of your generator NOTE Wheel kit is not intended for over the road use You will need a socket wrench with 1 2 or 13mm sockets and a needle nose pliers to install this kit Refer to Figure and install the wheel kit as follows Place the generator on a hard flat surface 2 Stand at the engine end of the generator and gently tilt the generator forward high enough to place wooden blocks beneath the cradle This will allow you to add the wheels Flat Washer 3 Slide the axle through the holes in the brackets provided on the generator cradle 4 Slide a wheel and flat washer on one end of the axle Make sure the air inflation valve is outward Insert the retaining pin 5 Slide the axle through until wheel is tight against bracket 6 Slide the other wheel and flat washer the other end of the axle Make sure the air inflation valve is outward Insert the retaining pin using the needle nose plier R
3. OUTLET 120 240 Locking 30A 189164GS 2 NUT Palnut Pushnut 12 84543CGS 2 SCREW Phillips Head 13 9385765 BAR Retaining 14 18889065 COVER Back Control Panel 15 8230865 6 5 Self Tapping 16 22694GS HOUSING Receptacle GENERAC Portable Products by Briggs amp Stratton POWER PRODUCTS DESCRIPCI N DEL EQUIPO Lea este manual de manera cuidadosa y familiaricese con su generador Conozca sus usos sus limitaciones y cualquier peligro relacionado con el mismo Este generador funciona en base a un motor de campo el ctrico giratorio y de corriente alterna AC Fue dise ado con la finalidad de proveer energ a el ctrica para luces el ctricas aparatos herramientas compatibles y cargas de motor El campo giratorio del generador funciona a una velocidad de 3 6000 rpm usando un motor con un solo cilindro PRECAUCI N No sobrepase la capacidad de vataje y amperaje del generador Revise No Sobrecargue el Generador en la p gina 27 Se ha hecho cada esfuerzo posible para asegurarse que la informaci n que aparece en este manual es exacta y se encuentra actualizada Sin embargo Generac se reserva el derecho a cambiar alterar o de otra manera mejorar el producto y este documento en cualquier momento sin previo aviso El Sistema de Control de Emisiones para este generador est garantizado para juegos est ndares por la Agencia de Protecci n Ambiental Para mayor informaci n acerca de la gar
4. Apagachispas Tuerca Mariposa para Conexi n a Tierra Terrapl n del aceite Agregue el aceite de motor aqu Tomacorriente Dobles de 120 Voltios AC 20 Amp Pueden ser utilizados para suministrar alimentaci n el ctrica para el funcionamiento de cargas del motor herramientas aparatos especiales e iluminaci n el ctrica de 120 Voltios AC 20 Amperios monof sica de 60 Hz Tomacorriente con Dispositivo de Seguridad de 120 240 Voltios 30 Amp Puede ser utilizado para suministrar alimentaci n el ctrica para el funcionamiento de cargas del motor herramientas aparatos especiales e iluminaci n el ctrica de 120 y o 240 Voltios AC 30 Amperios monof sica de 60 Hz Tuerca Mariposa para Conexi n a Tierra Usado para apropiado moli de la unidad vea p gina 25 CONEXION A TIERRA DEL GENERADOR El C digo Nacional de Electricidad exige que el marco y las partes exteriores del generador conductoras de electricidad est n conectadas a tierra adecuadamente Los c digos el ctricos locales tambi n pueden exigir que la unidad est conectada a tierra correctamente Para tal prop sito se ha instalado una tuerca mariposa para conexi n a tierra en la base del bastidor Figura 12 Figura 12 Tuerca Para Tierra Tuerca Mariposa para Conexi n a Tierra Por lo general la conexi n de un alambre de cobre trenzado No 12 AWG American Wire Gauge a la aleta de conexi n a tierra y a una bar
5. Rated Frequency 60 Hertz Fuel Tank Capacity 7 U S gallons Shipping Weight 175 lbs GENERAL MAINTENANCE RECOMMENDATIONS The Owner Operator is responsible for making sure that all periodic maintenance tasks are completed on a timely basis that all discrepancies are corrected and that the unit is kept clean and properly stored Never operate a damaged or defective generator Engine Maintenance See engine owner s manual for instructions If you need service for your engine you need to determine the engine identification number To do so remove the rocker arm cover hood item number 55 shown on page 16 by removing the four nuts and washers holding it in place The engine model type trim number is stamped on the side of the inner cover attached to the engine Have this number in hand when you call the engine service center for assistance CAUTION Avoid prolonged or repeated skin A contact with used motor oil Used motor oil has been shown to cause skin cancer in certain laboratory animals Thoroughly wash exposed areas with soap and water KEEP OUT OF REACH OF CHILDREN DON T POLLUTE CONSERVE RESOURCES RETURN USED OIL TO COLLECTION CENTERS 5500 Watt Heavy Duty Generator MAINTENANCE Generator Maintenance Generator maintenance consists of keeping the unit clean and dry Operate and store the unit in a clean dry environment where it will no
6. si el agua se introduce al generador a trav s de las ranuras para aire de enfriamiento algo del agua quedar retenida en los espacios 5500 Watt Pesado Generador vac os y grietas del aislamiento del devanado del estator y rotor La acumulaci n de agua y suciedad en los devanados internos del generador disminuir eventualmente la resistencia del aislamiento de estos devanados Para Limpiar el Generador PRECAUCION Nunca inserte objetos o herramientas a trav s de las ranuras de enfriamiento de aire incluso si el motor no est en funcionamiento Utilice un trapo h medo para limpiar las superficies exteriores Puede usar un cepillo de cerdas suaves para retirar la suciedad endurecida aceite etc Puede usar una m quina aspiradora para eliminar suciedad y residuos sueltos Puede usar aire a baja presi n que no exceda los 25 psi para eliminar la suciedad Inspeccione las ranuras para aire de enfriamiento y la apertura del generador Estas aperturas deber n mantenerse limpias y despejadas ALMACENAMIENTO El generador deber ser encendido al menos una vez cada siete d as y deber dejarlo funcionar al menos durante 30 minutos Si no puede hacer esto y debe almacenar la unidad por m s de 30 d as siga las siguientes instrucciones para preparar su unidad para almacenamiento Almacenando el Generador e Limpie el generador como est descrito en Para Limpiar el Generador e Revise que las ranura
7. Gauge WASHER Lock NUT WIRE Ground WASHER M6 Shakeproof DECAL Ground Green DECAL Danger DECAL Start Instructions MOUNT Vibration INSULATION HOOD Rocker Arm Cover CLIP Insulation ASSY Tank Fuel 7 Gallon Includes Items 41 amp 42 ASSEMBLY Control Panel NUT Palnut SHIELD Heat MANUAL Owners BOTTLE Oil 28 oz PLUG 250V 30A WIRE Ground Panel MANUAL Engine DECAL Panel Control DECAL Fuel Shut off PLATE Stiffener TIE WRAP ENGINE GENERAC 5500 Watt Heavy Duty Generator Portable Products by Briggs amp Stratton POWER PRODUCTS Item Part Qty Description 189715GS ASSEMBLY Handle 2 87101 5 LEG Mounting 3 5285865 5 NUT Locking Hex 4 3928765 2 HHCS M8 1 25 x 45 5 93693GGS AXLE 6 B4966GS 2 WHEEL 7 87005AGS 2 PIN Retaining 8 2224765 2 WASHER Flat 9 3925365 HHCS 8 1 25 x 20 10 42909GS 2 HHCS 8 1 25 x 30 2214565 2 WASHER Flat 12 27007GS 2 MOUNT Vibration 5500 Watt Heavy Duty Generator GENERAC Portable Products by Briggs amp Stratton POWER PRODUCTS Item Part Qty Description 18891465 COVER Lid Control Panel 2 18888965 CONTROL PANEL Compact 3 18916765 2 CLIP Hinge Pin Retainer 4 18918265 2 SPRING Hinge Pin 5 18916665 2 PIN Hinge Cover Compact 6 68759GS 2 OUTLET 120V 20Amp Duplex 7 18916565 4 NUT Palnut Pushnut 8 8419865 2 CAP Circuit Breaker 9 7520765 2 CIRCUIT BREAKER 10 43437GS
8. by Briggs amp Stratton POWER PRODUCTS EQUIPMENT DESCRIPTION Read this manual carefully and become familiar with your generator Know its applications its limitations and any hazards involved This generator is an engine driven revolving field alternating current AC generator It was designed to supply electrical power for operating compatible electrical lighting appliances tools and motor loads The generator s revolving field is driven at about 3 600 rpm by a single cylinder engine CAUTION Do Not exceed the generator s wattage amperage capacity See Don t Overload the Generator on page 9 Every effort has been made to ensure that information in this manual is accurate and current However Generac reserves the right to change alter or otherwise improve the product and this document at any time without prior notice The Emission Control System for this generator is warranted for standards set by the Environmental Protection Agency For warranty information refer to the engine owner s manual The engine exhaust from this product contains chemicals known to the State of California to cause cancer birth defects or other reproductive harm SAFETY RULES The safety alert symbol A is used with a signal word DANGER CAUTION WARNING a pictorial and or a safety message to alert you to hazards DANGER indicates a hazard which if not avoided will result in death or serious injury WARNING indicates a hazar
9. del generador Nunca de arranque o detenga el motor con todos los dispositivos el ctricos conectados y encendidos Deje que el motor funcione sin cargas por algunos minutos para estabilizar las temperaturas internas del motor y el generador e Mueva el interruptor balancin la posici n Off Apagado Cierre la v lvula del combustible RECEPT CULOS 120 240 Voltios AC 30 Amp Recept culo de Seguridad Use un tap n NEMA 14 30 con este recept culo Conecte un juego de cable de 4 alambres clasificado como 250 Voltios AC a 30 Amps o mayor Figura 16 Usted puede usar el mismo cable de 4 alambres si planea trabajar con una carga de 120 Voltios Este recept culo le provee poder a cargas de 120 240 Voltios AC de 60 Hz fase sencilla que requieren hasta 5 500 vatios de energ a 5 5 kW a 30 Amps para 120 Voltios o 240 Voltios La salida est protegida por un corto circuito de del tipo empuje para reposicionar PRECAUCI N Aunque esta salida tiene una A clasificaci n de 120 240 Voltios 30 Amps hasta 7 200 vatios el generador est clasificado solamente para 5 500 vatios Cargas que pasen la capacidad de amperaje y vataje del generador pueden da arlo o causar accidentes muy serios 5500 Watt Pesado Generador Figura 16 120 240 Volt AC 30 Amp Recept culo de Seguridad Juego de Cable de 4 Alambres 120V 120V W Neutro Y Ca
10. dicos de mantenimiento se lleven a cabo adecuadamente que todos los problemas son resueltos y que la unidad se mantiene limpia y adecuadamente almacenada Nunca opere un generador que est da ado o defectuoso Mantenimiento del Motor Consulte el manual del propietario del motor para las instrucciones de c mo mantener adecuadamente el motor PRECAUCI N Evite el contacto prolongado o repetido de piel con aceite usado de motor El aceite usado del motor ha sido mostrado al cancer de la piel de la causa en ciertos animales del laboratorio Completamente lavado expuso reas con el jab n y el agua MANTENGA FUERA DE ALCANCE DE NINOS CONTAMINE CONSERVE los RECURSOS VUELVA ACEITE USADO A la COLECCION CENTRA Mantenimiento del Generador El mantenimiento del generador consiste en conservar la unidad limpia y seca Opere y almacene la unidad en un ambiente limpio y seco donde no ser expuesta al polvo suciedad humedad o vapores corrosivos Las ranuras del aire de enfriamiento del generador no deben estar tapadas con nieve hojas o cualquier otro material extra os Revise frecuentemente la limpieza del generador y limpielo cuando est con polvo sucio con aceite humedad o cuando otras substancias extra as sean visibles en su superficie exterior NOTA No recomendamos el uso de mangueras de jard n para limpiar el generador El agua podr a introducirse en el sistema de combustible del motor y causar problemas Adem s
11. illustrations with your generator to familiarize yourself with the locations of various controls and adjustments Save this manual for future reference Recoil Starter Oil Fill Fuel Tank 120 Volt AC 20 Amp Duplex Receptacles Circuit 120 240 Volt AC Breakers AC 30 Amp Receptacle 120 Volt AC 20 Amp Duplex Receptacles May be used to supply electrical power for the operation of 120 Volt AC 20 Amp single phase 60 Hz electrical lighting appliance tool and motor loads 120 240 Volt AC 30 Amp Locking Receptacle May be used to supply electrical power for the operation of 120 and or 240 Volt AC 30 Amp single phase 60 Hz electrical lighting appliance tool and motor loads Air Cleaner Uses a dry type filter element to limit the amount of dirt and dust sucked into the engine Choke Lever Used when starting a cold engine Rocker Switch on engine shroud Mun Choke Lever Air Cleaner Spark Arrester Muffler Grounding Wing Nut Circuit Breakers AC Push to reset circuit breakers are provided to protect the generator against electrical overload Fuel Tank Capacity of seven 7 U S gallons Grounding Wing Nut Used for proper grounding of unit see page 7 Oil Fill Add engine oil here Recoil starter Used to start the engine Rocker Switch Set this switch to On before using recoil starter Set swit
12. minutes before refueling Do Not light a cigarette or smoke when filling the fuel tank 1 WARNING Do Not overfill the fuel tank Always allow room for fuel expansion Use regular UNLEADED gasoline with the generator engine Do Not use premium gasoline Do Not mix oil with gasoline e Clean area around fuel fill cap remove cap Slowly add unleaded regular gasoline to fuel tank Be careful not to overfill Allow about 1 5 of tank space for fuel expansion Figure 2 Figure 2 Typical Fuel Expansion Space Install fuel cap and wipe up any spilled gasoline IMPORTANT It is important to prevent gum deposits from forming in essential fuel system parts such as the carburetor fuel filter fuel hose or tank during storage Also experience indicates that alcohol blended fuels called gasohol ethanol or methanol can attract moisture which leads to separation and formation of acids during storage Acidic fuel can damage the fuel system of an engine while in storage To avoid engine problems the fuel system should be emptied before storage of 30 days or longer See Storage on page Never use engine or carburetor cleaner products in the fuel tank or permanent damage may occur GENERAC GENERAC Products by Briggs amp Stratton POWER PRODUCTS KNOW YOUR GENERATOR 5500 Watt Heavy Duty Generator Eee Read this owner s manual and safety rules before operating your generator Compare the
13. 0 Watt Pesado Generador LEA ESTE MANUAL DEL PROPIETARIO Y LAS REGLAS DE SEGURIDAD ANTES DE OPERAR SU GENERADOR Compare las ilustraciones con su Generador para familiarizarse con las ubicaciones de los diferentes controles y ajustes Conserve este manual para referencias futuras Culatazo el Principio Terrapl n del aceite Tanque de Combustible Tomacorrientes Doble de 120 Voltios AC 20 Amp Cortacircuitos Tomacorrientes con Dispositivo de Seguridad de 120 240 Voltios AC 30 Amp Cortacircuitos AC Cada tomacorriente posee un cortacircuito para proteger el generador contra sobrecargas el ctricas Los cortacircuitos son del tipo oprimir para reposicionar Culatazo el Principio Us para comenzar motor Depurador de Aire Filtra el aire de entrada a medida que penetra en el motor Interruptor Balanc n Deber estar en la posici n On En para darle arranque al motor Col quelo en la posici n Off Apagado para detener un motor en funcionamiento Palanca del Cebador Usada cuando se est dando arranque a un motor fr o Silenciador Apagachispas El silenciador disminuye el ruido del motor y est equipado con una pantalla apagachispas Tanque del Combustible El tanque tiene una capacidad de 7 galones americanos de gasolina sin contenido de plomo Interruptor Balanc n Palanca del Cebador rr Depurador de Aire Silenciador
14. 2 Conecte y encienda la primera carga preferiblemente la mayor que usted tenga 3 Permita que la salida del generador se estabilice el motor funciona suavemente y el aparato conectado al mismo trabaja adecuadamente GENERAC Portable Products by Briggs amp Stratton POWER PRODUCTS 4 Conecte y encienda la pr xima carga 5 nuevo permita que el generador se estabilice 6 Repita los pasos y 5 cada carga adicional que usted tenga Nunca a ada m s cargas sobre la capacidad del generador Tome una atenci n especial en considerar las cargas de corriente seg n la capacidad del generador como se describe arriba Figura 18 Guia de Referencia de Vatiaje Vatios Calificados cuando est funcionando Vatios Adicionales de Carga al encender Herramienta o Aparato El ctrico Esenciales Bombilla 75 vatios 75 Congelador industrial 500 500 Bomba de aguas negras 800 1200 Refrigerador congelador 18 pies 800 1600 c bicos Bomba de agua 1 3 HP 1000 2000 Calefacci n enfriamiento Aire Acond de ventana 10 000 BTU 1200 1800 Ventilador de ventana 300 600 Calefactor de caldera 1 2 HP 800 Cocina Horno de microondas 1 000 Vatios 1000 Cafetera 1500 Cocina el ctrica Elemento simple 1500 Calientaplatos 2500 Habitaci n Familiar Tocador de DVD CD 100 VCR 100 Receptor est reo 450 Televisor a color 27 pulg 500 Computadora personal con monitor de 800 17 pulg O
15. 4242GS 77816GS 91825GS 66849GS B4871GS 23762GS 86494GS 2 4 4 2 2 10 5 4 2 2 Qty Description CRADLE MOUNT Vibration 45 PPHMS M8 1 25 x 40 mm HOUSING Engine Adapter ASSEMBLY Rotor Inclds Item 7 ASSEMBLY Stator BEARING WASHER M8 Flat DECAL Cover Air Cleaner SCREW SEMS SCREW GROMMET Rubber GROMMET Rubber BRACKET Muffler GASKET Exhaust SCREW w Lock Washer MUFFLER SCREW SCREEN Spark Arrest PIN 4mm x 10 Roll NUT Flange Serrated DECAL 1 800 SCREW Self Drilling SHIELD Heat CARRIER Rear Bearing TAPTITE BOLT Stator SLEEVING Flexo FASTEN On Tab Housing 6P GROMMET Plastic DECAL Hot Muffler ASSEMBLY Brush Holder TAPTITE COVER Bearing Carrier WASHER Ext Shakeproof SCREW Wing Item Part B2153GS 56893GS 189948GS 77395GS 80270GS 78299GS 83465GS 7883 BGS B4363GS 22097GS 22127GS 14353621GS 26850GS B4986GS 92982GS 189235GS 85652GS 92665GS 187330GS 85000GS 1998 5 189157 5 189164 5 J92039GS 189828GS BB3061GS 43438GS 189521 5 188826 5 189949 5 73054 5 19001865 28739AGS NSP by Briggs amp Stratton POWER PRODUCTS Qty Description Aa LANUN rem SCREW Self Drilling SCREW Crimptite DECAL Heat Shield NUT 6 Flange Lock VALVE Tank BUSHING Plastic Tank GROMMET Tank HHCS SEMS CAP Fuel
16. ERAC E pa Briggs amp Stratton NOTES GENERAC 5500 Watt Heavy Duty Generator DIAGRAMS amp ortable Products by Briggs amp Stratton POWER PRODUCTS SCHEMATICS SCHEMATIC BRIDGE RECTIFIER BLUE 2 RED 6 4 EXCITATION n FIELD BLUE RED GRAY POWER em PDWER 44 BLUE RED GRAY an 22 44 Kee 120 20 C B 22 GRAY BLUE 120V 20A 440 142 BLUE CLA DIAGRAMS amp z DIAGRAMS amp 5500 Watt Heavy Duty Generator GENERAC Portable Products by Briggs amp Stratton POWER PRODUCTS WIRING DIAGRAM CIRCUIT CIRCUIT BREAKER BREAKER ts SIX LUG UCM CONNECTOR CONNEGTO HOUSING RED 22 GRN YEL 02 GRAY 44 CUSTOMER GROUND LUG q 9 9 K a gt q I 2 CH O LN LN e ortable Products by Briggs amp Stratton POWER PRODUCTS EXPLODED VIEW MAIN UNIT 69 2 lt lt ASX EN Lei SEN APRA Ve A SA 33 32 5500 Watt Heavy Duty Generator GENERAC ML s PARTS LIST MAIN UNIT Item Part OG c9 0 Jk A189503GS 70642GS 76222GS 66365GGS 187746GS 187745GS 65791GS 96796GS 189949GS 86307GS 99383GS 67022GS 189127GS 189009GS 188551GS 66476GS 189008GS 60706GS 83083GS 81917GS 67989GS 20566GS 86292GS J190061GS SRV66825DGS 74908GS 86308AGS 84409GS 22695GS 8
17. NTY ON GENERAC PORTABLE PRODUCTS EQUIPMENT SAVE YOUR PROOF OF PURCHASE RECEIPT IF YOU DO NOT PROVIDE PROOF OF THE INITIAL PURCHASE DATE AT THE TIME WARRANTY SERVICE IS REQUESTED THE MANUFACTURING DATE OF THE EQUIPMENT WILL BE USED TO DETERMINE THE WARRANTY PERIOD About your equipment warranty Generac Portable Products welcomes warranty repair and apologizes to you for being inconvenienced Any Authorized Service Dealer may perform warranty repairs Most warranty repairs are handled routinely but sometimes requests for warranty service may not be appropriate For example warranty would not apply if equipment damage occurred because of misuse lack of routine maintenance shipping handling warehousing or improper installation Similarly warranty is void if the serial number of the equipment has been removed or the equipment has been altered or modified If a customer differs with the decision of the Service Dealer an investigation will be made to determine whether the warranty applies Ask the Service Dealer to submit all supporting facts to its Distributor for review If the Distributor decides that the claim is justified the customer will be fully reimbursed for those items that are defective avoid misunderstandings that might occur between the customer and the Dealer listed below are some of the causes of equipment failure that the warranty does not cover Normal wear Outdoor Power Equipment like all mechanical devices needs periodic par
18. RLOAD THE GENERATOR See Don t Overload the Generator on page 9 Stopping the Engine Unplug all electrical loads from generator panel receptacles Never start or stop engine with electrical devices plugged in and turned ON Let engine run at no load for several minutes to stabilize the internal temperatures of engine and generator Move rocker switch to Off position Move the fuel valve to the Off position RECEPTACLES 120 240 Volt AC 30 Amp Locking Receptacle Use a NEMA 114 30 plug with this receptacle Connect 4 wire cord set rated for 250 Volt loads at 30 Amps or greater Figure 7 You can use the same 4 wire cord if you plan to run a 120 Volt load This receptacle powers 120 240 Volt AC 60 Hz single phase loads requiring up to 5 500 watts of power 5 5 kW at 30 Amps for 120 Volts or 240 Volts The outlet is protected push to reset circuit breaker 120 240 Volt 30 Amp rating up to 7 200 watts the generator is only rated for 5 500 watts Powering loads that exceed the wattage amperage capacity of the generator can damage it or cause serious injuries CAUTION Although this outlet states it has a Figure 7 120 240 Volt AC 30 Amp Receptacle 4 Wire Cord Set 240V 120V 120V W Neutral 0 Y Hot X Hot NEMA 114 30 Ground Green 120 Volt AC 20 Amp Duplex Receptacles Each duplex receptacl
19. ant a consulte con el manual del propietario del motor El escape del motor de este producto contiene elementos qu micos reconocidos en el Estado de California por producir c ncer defectos de nacimiento u otros da os de tipo reproductivo INSTRUCCIONES DE SEGURIDAD El s mbolo de alerta de seguridad es usado con una palabra PELIGRO ADVERTENCIA PRECAUCI N un mensaje por escrito o una ilustraci n para alertarlo acerca de cualquier situaci n de peligro que pueda existir PELIGRO indica un riesgo el cual si no se evita causar la muerte o una herida grave ADVERTENCIA indica un riesgo el cual si no se evita puede causar la muerte o una herida grave PRECAUCI N indica un riesgo el cual si no se evita puede causar heridas menores o moderadas PRECAUCI N cuando se usa sin el s mbolo de alerta indica una situaci n que podr a resultar en el da o del equipo Siga los mensajes de seguridad para evitar o reducir los riesgos de heridas e inclusive la muerte 5500 Watt Pesado Generador A PELIGRO Al generador funcionar se produce mon xido de carbono un gas inodoro y venenoso El respirar el mon xido de carbono producir n usea desmayo o la muerte Opere el generador SOLAMENTE al aire libre Mantenga al menos 2 pies de espacio libre alrededor del generador para la adecuada ventilaci n No opere el generador dentro de un edificio o lugar cerrado incluyendo el compartimiento del generador en u
20. aparatos el ctricos conectados al mismo Vea No sobrecargue su generador en la p gina 27 Encienda su generador y deje que el motor se estabilice antes de conectar las cargas el ctricas Conecte las cargas el ctricas en la posici n de apagado OFF luego encienda ON para su operaci n Apague OFF las cargas el ctricas y descon ctelas del generador antes de parar el generador PRECAUCION El tratamiento inadecuado del generador puede da arlo y acortar su vida productiva Use el generador solamente con la finalidad para el cual fue dise ado Si usted tiene alguna pregunta acerca de las finalidades de uso del generador preg ntele a su concesionario o contacte a Generac Opere el generador solamente en superficies niveladas No exponga al generador a una humedad excesiva polvo suciedad o vapores corrosivos No inserte cualquier objeto a trav s de las ranuras de enfriamiento Si los aparatos conectados se sobrecalientan ap guelos y descon ctelos del generador Apague el generador si Se pierde la salida el ctrica El equipo produce chispas humo o emite llamas La unidad vibra de una manera excesiva GENERAC Portable Products by Briggs amp Stratton POWER PRODUCTS Su generador requiere de ciertos procedimientos de montaje y solo estar listo para ser utilizado despu s de haberle suministrado servicio con el combustible y aceite recomendados Si usted tiene problemas con el montaje de s
21. asolina a presi n a o 90 d as 90 d as El periodo de garant a comienza en la fecha de compra hecha por el primer consumidor al detal o usuario comercial y contin a por el periodo de tiempo que aparece en la tabla arriba mencionada Para uso del consumidor significa uso residencial por un consumidor al detal Para uso comercial significa todos los otros casos incluyendo el uso comercial para generar un ingreso o por prop sitos de alquiler Una vez que el equipo ha sido usado comercialmente deber a ser considerado como de uso comercial para las finalidades de esta garant a El equipo usado el equipo de demostraci n y el equipo usado como energ a primaria en lugares donde las utilidades p blicas no est n garantizados Los accesorios tales como pistolas mangueras varillas y boquillas est n excluidos de la garant a del producto El motor a gasolina y las bater as para el encendido est n garantizados por el fabricante de esos productos EL REGISTRO DE LA GARANT A NO ES NECESARIO PARA OBTENER LA GARANT A EN LOS EQUIPOS PORT TILES DE GENERAC GUARDE SU RECIBO DE COMPRA SI USTED NO PROVEE LA PRUEBA DE LA FECHA DE LA COMPRA INICIAL AL MOMENTO EN QUE SE REQUIERA USAR LA GARANT A LA FECHA DE LA FABRICACI N DEL EQUIPO SER USADA PARA DETERMINAR EL PERIODO DE GARANT A Acerca de la seguridad de su equipo Los Productos Port tiles Generac reciben las reparaciones bajo la garant a y le pide disculpas por cualquier
22. ch to Off to switch off engine Spark Arrester Muffler Exhaust muffler lowers engine noise and is equipped with a spark arrester screen GROUNDING THE GENERATOR The National Electrical Code requires that the frame and external electrically conductive parts of this generator be properly connected to an approved earth ground Local electrical codes may also require proper grounding of the unit For that purpose a GROUNDING WING NUT is provided on the generator end Figure 3 Figure 3 Grounding Wing Nut Generally connecting a No 12 AWG American Wire Gauge stranded copper wire to the grounding wing nut and to an earth driven copper or brass grounding rod electrode provides adequate protection against electrical shock Be careful to keep the grounding wire attached after connecting the stranded copper wire However local codes may vary widely Consult with a local electrician for grounding requirements in your area Properly grounding the generator helps prevent electrical shock if a ground fault condition exists in the generator or in connected electrical devices Proper grounding also helps dissipate static electricity which often builds up in ungrounded devices OPERATING THE GENERATOR CAUTION Never start or stop the engine with electrical loads connected to the receptacles AND with the connected devices turned ON Starting the Engine Disconnect all electrical loads from the generator Use the fol
23. consiga el concesionario autorizado m s cercano en nuestro mapa localizador de concesionarios www generac portables com o llame al 1 877 544 0982 NO EXISTE OTRA GARANT A EXPRESA LAS GARANT AS IMPL CITAS INCLUYENDO AQUELLAS DE MERCANTIBILIDAD O CAPACIDAD PARA UN PROP SITO PARTICULAR EST N LIMITADAS AL PERIODO DE TIEMPO ESPECIFICADO O HASTA EL L MITE PERMITIDO POR LA LEY TODA Y CUALQUIER GARANT A IMPL CITA EST EXCLUIDA RESPONSABILIDAD POR DA OS CONSECUENTES BAJO CUALQUIER Y TODAS LAS GARANT AS EST N EXCLUIDAS HASTA EL L MITE DE EXCLUSI N PERMITIDO POR LA LEY Algunos estados no permiten limitaciones en cu nto y cu n implicadas las garant as pueden ser y algunos estados no permiten la exclusi n o limitaci n de da os incidentales o consecuentes por lo que las limitaciones y exclusiones arriba mencionadas es posible que no se apliquen a usted Esta garant a le proporciona derechos legales espec ficos y es posible que usted tenga otros derechos los cuales pueden variar de estado a estado y de pa s a pa s PERIODO DE GARANTIA PRODUCTOS PARA USO DEL CONSUMIDOR PARA USO COMERCIAL UNIDADES REACONDICIONADAS POR LA FABRICA Generador portatil a o 90 dias 90 dias Valvula lateral con motor Generador portatil 2 afios a o 90 dias Motor de v lvula superior el segundo a o solamente para las partes Lavador el ctrico a presi n a o ninguno ninguno Lavador de g
24. d which if not avoided could result in death or serious injury CAUTION indicates a hazard which if not avoided might result in minor or moderate injury CAUTION when used without the alert symbol indicates a situation that could result in equipment damage Follow safety messages to avoid or reduce the risk of injury or death SAFETY RULES A DANGER Running generator gives off carbon monoxide an ordorless colorless poison gas Breathing carbon monoxide will cause nausea fainting or death Operate generator ONLY outdoors Keep at least 2 feet of clearance on all sides of generator for adaquate ventilation Do not operate generator inside any building or enclosure including the generator compartment of a recreational vehicle RY A WARNING Gasoline and its vapors are extremely flammable and explosive Fire or explosion can cause severe burns or death WHEN ADDING FUEL Turn generator OFF and let it cool at least 2 minutes before removing gas cap Loosen cap slowly to relieve pressure in tank Fill fuel tank outdoors Do not overfill tank Allow space for fuel expansion Keep gasoline away from sparks open flames pilot lights heat and other ignition sources Do not light a cigarette or smoke WHEN OPERATING EQUIPMENT Do not tip engine or equipment at angle which causes gasoline to spill WHEN TRANSPORTING OR REPAIRING EQUIPMENT Transport repair with fuel tank EMPTY or with fuel shutoff va
25. de concesionarios en www generac portables com o llame al 1 877 544 0982 Los Productos Port tiles de Generac est n fabricados bajo una o m s de las siguientes patentes Otras patentes est n pendientes 5902094 5823752 5718255 5890413 Generac Portable Products LLC Jefferson Wisconsin U S A LIMITED WARRANTY GENERAC PORTABLE PRODUCTS OWNER WARRANTY POLICY Effective October 2001 LIMITED WARRANTY Generac Portable Products LLC will repair or replace free of charge any part or parts of the equipment that are defective in material or workmanship or both Transportation charges on parts submitted for repair or replacement under this Warranty must be borne by purchaser This warranty is effective for the time periods and subject to the conditions provided for in this policy For warranty service find the nearest Authorized Service Dealer in our dealer locator at www generac portables com or call 1 877 544 0982 THERE IS NO OTHER EXPRESS WARRANTY IMPLIED WARRANTIES INCLUDING THOSE OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE LIMITED TO THE TIME PERIOD SPECIFIED OR TO THE EXTENT PERMITTED BY LAW ANY AND ALL IMPLIED WARRANTIES ARE EXCLUDED LIABILITY FOR CONSEQUENTIAL DAMAGES UNDER ANY AND ALL WARRANTIES ARE EXCLUDED TO THE EXTENT EXCLUSION IS PERMITTED BY LAW Some states do not allow limitations on how long an implied warranty lasts and some states do not allow the exclusion or limitation of incidental
26. e Figure 8 is protected against overload by push to reset circuit breaker Figure 8 120 Volt 20 Amp Duplex Receptacle Use each receptacle to operate 120 Volt AC single phase 60 Hz electrical loads requiring up to 2 400 watts 2 4 kW at 20 Amps of current Use cord sets that are rated for 125 Volt AC loads at 20 Amps or greater CAUTION These outlets are rated at 120 Volt A 20 Amp each up to 80 Amps The generator is only rated for up to 45 8 Amps Powering loads that exceed the wattage amperage capacity of the generator can damage it or cause serious injuries DON T OVERLOAD YOUR GENERATOR Capacity You must make sure your generator can supply enough rated running and surge starting watts for the items you will power at the same time Follow these simple steps Select the items you will power at the same time 2 Total the rated running watts of these items This is the amount of power your generator must produce to keep your items running See Figure 9 3 Estimate how many surge starting watts you will need Surge wattage is the short burst of power needed to start electric motor driven tools or appliances such as a circular saw or refrigerator Because not all motors start at the same time total surge watts can be estimated by adding only the item s with the highest additional surge watts to the total rated watts from step 2 Example Rated Running Additional Surge Tool o
27. e severe chemical burns Operate generator only on level surfaces Do not expose generator to excessive moisture dust dirt or corrosive vapors Do not insert any objects through cooling slots If connected devices overheat turn them off and disconnect them from generator Shut off generator if Do not allow any open flame spark heat or lit cigarette electrical output is lost during and for several minutes after charging a battery equipment sparks smokes or emits flames e Wear protective goggles rubber apron and rubber gloves unit vibrates excessively GENERAC 5500 Watt Heavy Duty Generator ortable Products by Briggs amp Stratton POWER PRODUCTS Your generator requires some assembly and is ready for use after it has been properly serviced with the recommended oil and fuel If you have any problems with the assembly of your generator please call the generator helpline at 1 800 270 1408 IMPORTANT Any attempt to run the unit before it has been serviced with the recommended oil will result in an engine failure REMOVE GENERATOR FROM CARTON Set the carton on a rigid flat surface with This Side Up arrows pointing upward Carefully open the top flaps of the shipping carton Cut down corners at one end of carton from top to bottom and lay that side of carton down flat Remove all packing material carton fillers etc Remove the generator from the shipping carton Figure
28. emove the wooden blocks 7 Attach the vibration mounts to the support leg with 30mm capscrews washers and lock nuts 8 To aid support leg assembly rest generator on cradle engine end down Remove the existing hardware from the left unit vibration mount with 13mm wrench Use the same hardware to attach the support leg 9 Attach the other side of the support leg with a 20mm cap screw and lock nut Rest generator on wheels and support leg 10 Center the handle bracket on generator frame at support leg end of cradle as shown Attach handle bracket with two M8 x 45mm screws and two locking hex nuts 12 Check each fastener to ensure it is secure and the tires are inflated between 15 40 PSI BEFORE STARTING THE ENGINE Add Oil CAUTION Any attempt to crank or start the engine before it has been properly filled with the recommended oil may result in an engine failure To fill your engine with oil Place generator on a level surface Follow the oil grade recommendations and oil fill instructions given in the engine owner s manual NOTE The generator s revolving field rides on a prelubricated and sealed ball bearing that requires no additional lubrication for the life of the bearing 5500 Watt Heavy Duty Generator GENERAC by Briggs 8 Stratton POWER PRODUCTS Add Gasoline WARNING Never fill fuel tank indoors Never fill fuel tank when engine is running or hot Allow unit to cool for two
29. enerator circuit 4 Contact Generac service facility Rocker switch set to Off Set switch to On 2 Fuel valve is in the Closed position 2 Turn fuel valve to the Open position 3 Low oil level 3 Fill crankcase to proper level 4 Dirty air cleaner 4 Clean or replace air cleaner 5 Out of gasoline 5 Fill fuel tank Engi 6 Stale gasoline 6 Drain gas tank and fill with fresh fuel ngine will not start or starts and pune 7 Spark plug wire not connected to 7 Connect wire to spark plug rough spark plug 8 Bad spark plug 8 Replace spark plug 9 Water in gasoline 9 Drain gas tank fill with fresh fuel 10 Overchoking 10 Set choke to Off position Excessively rich fuel mixture Contact Briggs service facility 12 Intake valve stuck open or closed 12 Contact Briggs service facility 13 Engine has lost compression 13 Contact Briggs service facility Engine shuts down Out of gasoline Fill fuel tank during operation 2 Fault in engine 2 Contact Briggs service facility Load is too high See Don t Overload the Generator on Engine lacks power page 9 2 Dirty air filter 2 Replace air filter Choke is opened too soon Move choke to halfway position till engine Engine hunts or runs smoothly falters 2 Carburetor is running too rich or too 2 Contact Briggs service facility lean NOTES 5500 Watt Heavy Duty Generator GEN
30. inconveniencia causada Cualquier Concesionario de Servicio Autorizado puede llevar a cabo reparaciones bajo la garant a La mayor a de las reparaciones bajo la garant a son manejadas normalmente pero algunas veces la solicitud del servicio de garant a es posible que no sea apropiada Por ejemplo la garant a no ser v lida si el da o al equipo ocurri debido al mal uso falta de mantenimiento adecuado manejo env o almacenamiento o una instalaci n inadecuada Similarmente la garant a es anulada si el n mero de serial del equipo ha sido removido o el equipo ha sido alterado o modificado Si un cliente no est de acuerdo con la decisi n hecha por el Concesionario de Servicio se llevar a cabo una investigaci n para determinar si la garant a se puede aplicar Pida al Concesionario de Servicio que entregue todos los hechos que soportan su decisi n a su Distribuidor para que ste los revise Si el Distribuidor decide que el reclamo es justificado al cliente se le reembolsar completamente por todos esos art culos que est n defectuosos Para evitar un malentendido que pueda ocurrir entre el Concesionario y el cliente abajo aparecen algunos de las razones por las cuales el equipo puede fallar y que la garant a no cubre Desgaste normal Equipo el ctrico al aire libre como todos los aparatos mec nicos necesita partes servicio y reemplazo peri dicamente para que funcione bien Esta garant a no cubre la reparaci n cuando el uso n
31. io Generac Corto circuito en una de las cargas la carga el ctrica en corto conectadas El motor funciona bien 2 El generador est sobrecarga 2 Vea No Sobrerecarque el Generador en la sin carga pero funciona p gina 27 mal cuando se le 3 Velocidad del motor es muy lenta 3 Contacte el Departmento de Servicio Briggs contectan cargas and Stratton 4 Circuito del generador en corto 4 Contacte el Departmento de Servicio Generac Interruptor Run Stop poscioando en Off Coloque del interruptor en On 2 V lvula del Combustible en posici n Off 2 Gire la v lvula del combustible a la posici n On 3 Depurador de aire sucio 3 Limpie o reemplace el depurador de aire 4 Sin gasolina 4 con combustible fresco 5 Gasolina vieja 5 el tanque de gasolina ll nelo con combustible fresco El 6 El cable de la buj a no est en malas la buj a 6 Conecte el cable a la buj a motor no se enciende ose enciende 7 Bujia defectuosa 7 Reemplace la buj a 8 Agua en la gasolina 8 Drene el tanque de gasolina ll nelo con y funciona mal combustible fresco 9 Sobrecebado 9 Abra por completo el cebador y haga girar el motor 10 Mezcla de combustible excesivamente rica 10 Contacte el Departmento de Servicio Briggs La v lvula de corte de combustible Contacte el Departmento de Servicio Briggs 12 La v lvula de entrada es
32. ir slots and openings on generator are open and unobstructed 5500 Watt Heavy Duty Generator GENERAC Portable Products by Briggs amp Stratton POWER PRODUCTS CAUTION Storage covers can be flammable A Do Not place a storage cover over a hot generator Let the unit cool for a sufficient time before placing the cover on the unit Engine Storage See engine owner s manual for instructions Other Storage Tips Do Not store gasoline from one season to another Replace fuel container if it starts to rust Rust and or dirt in fuel can cause problems if it s used with this unit Store in clean and dry area GENERAC 5500 Watt Heavy Duty Generator ortable Products by Briggs amp Stratton POWER PRODUCTS TROUBLESHOOTING Problem Cause TROUBLE SHOOTING Solution Circuit breaker is open Reset circuit breaker Engine is running but 2 Poor connection or defective cord set 2 Check and repair no AC output is 3 Connected device is bad 3 Connect another device that is in good available condition 4 Fault in generator 4 Contact Generac service facility Short circuit a connected load l Disconnect shorted electrical load 2 Generator is overloaded 2 See Don t Overload the Generator on Engine runs good but 9 bogs down when 3 Engi e Engine speed is too slow 3 Contact Briggs and Stratton service loads are connected facility 4 Shorted g
33. lowing start instruction steps by numerical order 5500 Watt Heavy Duty Generator GENERAC Portable Products by Briggs amp Stratton POWER PRODUCTS Turn the fuel valve to the On position Figure 4 Figure 4 Fuel Valve FUEL TANK Fuel Valve is shown in the On position 2 Place the choke lever in the Choke position Figure 5 Figure 5 Choke Lever 3 Set the rocker switch to On position Figure 6 4 Grasp the recoil handle and pull slowly until slight resistance is felt Then pull rapidly to start engine 5 Move choke lever to Run position a short distance at a time over several seconds in warm weather or minutes in cold weather Let engine run smoothly before each change Operate with choke in Run position NOTE If engine still fails to start see engine manual This engine may be equipped with a low oil device Refer to the engine owner s manual for more detailed starting instructions GENERAC 5500 Watt Heavy Duty Generator ortable Products by Briggs amp Stratton POWER PRODUCTS Connecting Electrical Loads Let engine stabilize and warm up for a few minutes after starting Plug in and turn on the desired 120 and or 240 Volt AC single phase 60 Hz electrical loads Do Not connect 240 Volt loads to the 120 Volt duplex receptacles Do Not connect 3 phase loads to the generator Do Not connect 50 Hz loads to the generator DO NOT OVE
34. lve OFF Disconnect spark plug wire WHEN STORING GASOLINE OR EQUIPMENT WITH FUEL IN TANK Store away from furnaces stoves water heaters clothes dryers or other appliances that have pilot light or other ignition source because they can ignite gasoline vapors SAFETY RULES 5500 Watt Heavy Duty Generator GENERAC by Briggs amp Stratton POWER PRODUCTS Generator produces powerful voltage Running engines produce heat Temperature of NO Failure to properly ground generator can result muffler and nearby areas can reach or exceed in electrocution 150 F 65 C Failure to isolate generator from power utility Severe burns can occur on contact can result in death or injury to electric utility Do not touch hot surfaces workers due to backfeed of electrical energy Allow equipment to cool before touching When using generator for backup power notify utility company Use approved transfer equipment to isolate A CAUTION generator from electric utility e e a Excessively high operating speeds increase risk of injury National Electric Code requires generator to be properly and damage to generator grounded to an approved earth ground Call an electrician for local grounding requirements Excessively low speeds impose a heavy load Use a ground fault circuit interrupter GFCI in any damp or Do not tamper with governed speed Generator supplies highly conductive area such as metal decking or s
35. n veh culo recreativo o RV A ADVERTENCIA La gasolina y sus vapores son extremadamente A inflamables y explosivos El fuego o una explosi n pueden causar quemaduras M severas e inclusive la muerte CUANDO A ADA COMBUSTIBLE Apague el generador posici n OFF y d jelo enfriar al menos por 2 minutos antes de remover la tapa de la gasolina Afloje la tapa lentamente para dejar que la presi n salga del tanque Llene el tanque al aire libre No llene demasiado el tanque Permita al menos espacio para la expansi n del combustible Mantenga la gasolina alejada de chispas llamas abiertas pilotos calor y otras fuentes de ignici n No encienda un cigarrillo o fume CUANDO OPERE EL EQUIPO No incline el motor o el equipo de tal manera que la gasolina se pueda derramar CUANDO TRANSPORTE O REPARE EL EQUIPO Transporte o repare el equipo con el tanque de combustible vac o con la v lvula para apagar el combustible apagada posici n OFF Desconecte el cable de la buj a CUANDO ALMACENE O GUARDE EL EQUIPO CON COMBUSTIBLE EN EL TANQUE Almacene alejado de calderas estufas calentadores de agua secadoras de ropa u otros aparatos electrodom sticos que posean pilotos u otras fuentes de ignici n porque ellos pueden encender los vapores de la gasolina 5500 Watt Pesado Generador ADVERTENCIA Los generadores producen un voltaje muy poderoso XL 0 Si no hace tierra apropiadamente c
36. nsas de punta para instalar el juego de ruedas Consulte la Figura 10 y instale el juego de ruedas como se describe a continuaci n Coloque el generador sobre una superficie plana y dura Arandela 2 en el extremo del motor del generador e incline el generador cuidadosamente hacia adelante lo suficiente como para colocar bloques por debajo del armaz n Esto le permitir colocar las ruedas 3 Pase el eje a trav s de los orificios de las m nsulas del armaz n del generador 4 Coloque las ruedas y las arandelas planas cada extremo del eje Aseg rese de instalar ambas ruedas con la v lvula de aire hacia el lado de afuera Insertar los pasadores de retenci n 5 Deslice el eje por hasta que la rueda sea apretada contra par ntesis 6 Deslice la otra rueda y arandela plana en el otro fin del eje Insertar los pasadores de retenci n usa unas pinsas de punta Remover los bloques madera 7 Instale los montajes antivibratorios a la pata de soporte utilizando dos tornillos prisioneros 30mm arandelas y tuercas de seguridad 8 Para ayudar al ensamblaje de la pata de apoyo haga descansar el generador en la camilla con la parte del motor hacia abajo Quite el hardware existente del monte izquierdo de la vibraci n de la unidad con 3mm llave inglesa Use el mismo hardware para conectar la pierna de apoyo 9 Conecte el otro lado de la pierna de apoyo con un 20mm tornillo de la tapa y nuez de cer
37. on un generador puede hacer que ocurra electrocutamiento Si no a sla el generador de utilidades de energ a puede hacer que los trabajadores de electricidad sufran heridas graves e inclusive la muerte debido a la retroalimentaci n de la energ a el ctrica Cuando use un generador como poder de energ a auxiliar notifique a la compa a de utilidades Use el equipo de transferencia aprobado para aislar el generador de otra utilidad el ctrica Los C digos Nacionales para la Electricidad requieren que los generadores est n haciendo tierra de una manera aprobada Llame a un electricista para conocer los requisitos locales para hacer tierra Use un interruptor para la falla del circuito de tierra GFCI en cualquier rea bastante h meda o que sea altamente conductiva tales como terrazas de metal o trabajo hecho con acero No toque los alambres pelados o recept culos No use un generador con cables el ctricos que est n malgastados rotos pelados o da ados de cualquier forma No opere el generador bajo la lluvia No maneje el generador o cables el ctricos mientras est parado en agua descalzo o cuando las manos y los pies est n mojados No permita que personas descalificadas o ni os operen o sirvan al generador PELIGRO Las bater as almacenadas producen hidr geno explosivo mientras est n siendo recargadas El hidr geno puede permanecer cerca de la bater a por un periodo largo de tiempo despu
38. or consequential damages so the above limitation and exclusion may not apply to you This warranty gives you specific legal rights and you may also have other rights which vary from state to state and country to country WARRANTY PERIOD PRODUCTS CONSUMER USE COMMERCIAL USE FACTORY RECONDITIONED UNITS Portable Generator year 90 days 90 days Side Valve Engine Powered Portable Generator 2 years year 90 days Overhead Valve Engine Powered 2nd year parts only Electric Powered Pressure Washer year None None Gasoline Powered Pressure Washer year 90 days 90 days The warranty period begins on the date of purchase by the first retail consumer or commercial end user and continues for the period of time stated in the table above Consumer use means personal residential household use by a retail consumer Commercial use means all other uses including use for commercial income producing or rental purposes Once equipment has been used commercially it shall thereafter be considered to be in commercial use for purposes of this warranty Used equipment demonstration equipment and equipment used for prime power in place of a utility are not warranted Accessory parts such as guns hoses wands and nozzles are excluded from the product warranty The gasoline engine and starting batteries are warranted solely by the manufacturers of those products WARRANTY REGISTRATION IS NOT NECESSARY TO OBTAIN WARRA
39. ormal ha acabado con la vida de una parte en particular o del equipo Instalaci n y mantenimiento Esta garant a no se aplica al equipo o parte que ha estado sujeta a una instalaci n inadecuada que no haya sido autorizada o a cualquier tipo de alteraci n el mal uso negligencia accidentes sobrecarga velocidad excesiva mantenimiento inadecuado reparaci n o almacenamiento que seg n la opini n de los Productos Port tiles Generac han afectado desfavorablemente su rendimiento y fiabilidad Esta garant a tambi n no cubre el mantenimiento normal tales como ajustes limpieza del sistema de combusti n y la obstrucci n debido a materias qu micas suciedad carb n o cal etc Otras exclusiones Tambi n se encuentran excluidos de est garant a el desgaste de los art culos tales como conectadores medidores de aceite correas anillos O filtros empaque de la bomba etc las bombas que se hagan funcionar o trabajar sin agua o da os y malfuncionamientos que resulten de accidentes abusos modificaciones alteraciones un servicio inadecuado congelamiento o deterioro qu mico La garant a se encuentra disponible solamente a trav s de los concesionarios de servicios autorizados por los Productos Port tiles Generac Esta garant a no se aplica al servicio proveniente de cualquier otra entidad Usted puede ubicar su Concesionario de Servicio Autorizado de los Productos Port tiles de Generac m s cercano en nuestro mapa localizador
40. r Appliance 5500 Watt Heavy Duty Generator Watts Starting Watts Window Air 1200 1800 Conditioner Refrigerator 800 1600 Deep Freezer 500 500 Television 500 Light 75 Watts 75 3075 Total 1800 Highest Running Watts Surge Watts Total Rated Running Watts 3075 Highest Additional Surge Watts 1800 Total Generator Output Required 4875 Power Management To prolong the life of your generator and attached devices it is important to take care when adding electrical loads to your generator There should be nothing connected to the generator outlets before starting it s engine The correct and safe way to manage generator power is to sequentially add loads as follows With nothing connected to the generator start the engine as described in this manual 2 Plugin and turn on the first load preferably the largest load you have 3 Permit the generator output to stabilize engine runs smoothly and attached device operates properly GENERAC Portable Products by Briggs amp Stratton POWER PRODUCTS 4 Plugin and turn on the next load 5 Again permit the generator to stabilize 6 Repeat steps 4 and 5 for each additional load Never add more loads than the generator capacity Take special care to consider surge loads in generator capacity as described above Figure 9 Wattage Reference Chart Additional Surge Starting Watts Rated Running Watts Tool or Appliance Essen
41. r SIN CONTENIDO DE PLOMO en el generador No use gasolina premium No mezcle aceite con gasolina Limpie el rea alrededor del llenado de gasolina retire la tapa Llene lentamente el tanque con gasolina sin contenido de plomo Sea cuidadoso de no llenar excesivamente Deje 1 5 de espacio en el tanque para que la expansi n del combustible como se muestra en esta ilustraci n Figura Figura Espacio T pico para la Expansi n del Combustible e Instale la tapa del combustible y limpie cualquier derrame de gasolina IMPORTANTE Es importante evitar la formaci n de dep sitos de goma en las partes esenciales del sistema de combustible como en el carburador filtro del combustible manguera del combustible o tanque durante su almacenamiento Los combustibles mezclados con alcohol llamados gasohol etanol o metanol pueden atraer la humedad la cual produce la separaci n y formaci n de cidos durante el almacenamiento La gasolina cida puede da ar el sistema de combustible de un motor durante su almacenamiento Para evitar problemas en el motor deber vaciar el sistema de combustible antes de per odos de almacenamiento de 30 d as o m s Vea Almacenamiento en la p gina 28 Nunca use productos para limpiar motores o carburadores en el tanque del combustible si lo hace ocurrir n da os permanentes GENERAC Portable Products by Briggs amp Stratton POWER PRODUCTS CONOZCA SU GENERADOR 550
42. ra de conexi n a tierra de cobre o bronce electrodo proporciona una protecci n adecuada contra las descargas el ctricas Sin embargo los c digos locales pueden variar substancialmente Consulte con un electricista local para conocer los requisitos de conexi n a tierra de su rea La conexi n a tierra adecuada del generador ayudar a evitar las descargas el ctricas en el caso de que exista una condici n de falla a tierra en el generador o en los dispositivos el ctricos conectados La conexi n a tierra adecuada tambi n ayuda a disipar la electricidad est tica la cual se acumula frecuentemente en dispositivos no conectados a tierra OPERANDO EL GENERADOR PRECAUCI N Nunca encienda o pare el motor con las cargas el ctricas conectadas a los recept culos Y con los aparatos conectados ENCENDIDOS Encienda el Motor Desconecte todas las cargas el ctricas del generador Use las siguientes instrucciones para encender paso por paso en orden num rico Gire la v lvula del combustible a la posici n On Figura 13 5500 Watt Pesado Generador RAC Portable Products by Briggs amp Stratton POWER PRODUCTS Figura 13 Valvula de Combustible FUEL TANK Valvula del Combustible en posici n On 2 Coloque la palanca de choke en la posici n Choke Figura 14 Figura 14 Palanca Choke 3 Coloque el interruptor balanc n la posici n On Figura 15 Figura 15 In
43. radura Descanse el generador en la pierna de ruedas y apoyo 10 Coloque el soporte de la manilla en el centro del marco del generador al extremo de la pata de apoyo como se muestra Anexe el soporte de la manilla con dos tornillos 45mm y dos tuercas de seguridad 12 Verifique que todas las piezas est n apretadas y las llantas est n infladas con aire entre 15 40 PSI ANTES DE DARLE ARRANQUE AL MOTOR Agregar Aceite al Motor CAUTION Cualquier intento para arancar el motor antes de haberle proporcionado el mantenimiento apropiado con el aceite recomendado podr a ocasionar la falla del motor e Coloque la generador sobre una superficie nivelada Consulte el manual del propietario del motor para a adir al motor el aceite recomendado NOTA El campo giratorio del generador se encuentra en un cojinete pre lubricado y sellado que no requiere lubricaci n adicional por la vida til del cojinete 5500 Watt Pesado Generador Portable Products by Briggs amp Stratton POWER PRODUCTS Agregue Gasolina ADVERTENCIA Nunca llene el tanque del combustible en recintos cerrados Nunca llene el tanque del combustible cuando el motor est en funcionamiento o caliente No encienda cigarrillos o fume cuando est llenando el tanque del combustible ADVERTENCIA No llene excesivamente el tanque de combustible Deje suficiente espacio para la expansi n del combustible Use gasolina regula
44. rga es la cantidad m nima de electricidad necesaria para encender herramientas o aparatos con motores el ctricos tales como sierras circulares o refrigeradores Debido a que no todos los motores se encienden al mismo momento el vataje total de carga se puede estimar al a adir solamente el los aparato s con el vataje adicional m s alto al total del vataje calificado obtenido en el paso 2 5500 Watt Pesado Generador Ejemplo Herramienta o Manes Calificados Vatios Adicionales de Aparato El ctrico Ta SE Carga al encender uncionando Aire Acondicionado 1200 1800 de Ventana Refrigerador 800 1600 Congelador industrial 500 500 Televisi n 500 Luz 75 Vatios 75 Total 3075 1800 Vatios de Vatios para funcionar Carga m s alto Vataje Total Calificado cuando est funcionando 3075 1800 4875 Vataje de Carga Adicional m s alto Salida Total Requerida del Generador Control de la Energ a Para prolongar la vida de su generador y los aparatos que est n conectados al mismo es muy importante cuidarlo cuando se le a aden cargas el ctricas Nada deber a estar conectado a los tomacorrientes del generador antes de que su motor sea encendido La forma correcta y m s segura para controlar la energ a del generador es la de a adir en secuencias las cargas como se describe a continuaci n tener nada conectado al generador encienda el motor de la manera descrita en este manual
45. rgado X Cargado NEMA LI4 30 L Tierra Verde 120 Volt AC 20 Amp Recept culos Dobles Cada recept culo Figura 17 est protegido en contra de sobrecargas por un corto circuitos de del tipo empuje para reposicionar Figura 17 120 Volt AC 20 Amp Recept culo Doble Use cada recept culo para operar 120 Voltios AC de fase sencilla de cargas de 60Hz que requieren hasta 2 400 vatios 2 4 kW a corrientes de 20 Amps Use los juegos de cables que son calificados para cargas de 125 Voltios AC a 20 Amps o mayores PRECAUCI N Estas salidas se valoran en 120 Voltios 20 Amps hasta 80 Amps El generador es s lo valorado hasta 45 8 Amps Las cargas que accionan que excede el wattage la capacidad de amperaje del generador lo puede dafiar o causar las heridas gravas NO SOBRECARGUE EL GENERADOR Capacidad Usted debe asegurarse que su generador puede proveer el suficiente vataje calificado cuando est funcionando y de carga al encender para los aparatos a los cuales va a proveer la energ a al mismo tiempo Siga estos pasos Seleccione los aparatos que recibir n la energ a al mismo tiempo 2 Totalice los vatios calificados cuando est funcionando de estos aparatos Esta es la cantidad de energ a que su generador debe producir para mantener eso aparatos funcionando adecuadamente Vea la Figura 18 3 Calcule la cantidad de vatios de carga al encender que usted necesitar El vataje de ca
46. s para el aire de enfriamiento y las aperturas del generador se encuentren abiertas y despejadas PRECAUCI N Las cubiertas para almacenamiento pueden ser inflamables No coloque una cubierta encima de un generador caliente Deje que la unidad se enfr e lo suficientemente antes de que le coloque la cubierta Almacenando el Motor Consulte el manual del propietario del motor para las instrucciones de c mo preparar adecuadamente el motor para su almacenamiento Otras Sugerencias Para el Almacenando e almacene gasolina de una estaci n a otra e Reemplace la caneca de gasolina si comienza a oxidarse El xido y o la suciedad en la gasolina le causar problemas e Almacene la unidad en un rea limpia y seca o 5500 Watt Pesado Generador GENERAC Portable Products by Briggs amp Stratton POWER PRODUCTS NOTAS GENERAC Portable Products by Briggs amp Stratton POWER PRODUCTS 5500 Watt Pesado Generador DIAGNOSITICOS DE AVER AS REPARACION pr Problemo Causa Accion interruptor autom tico de circuito esta el interruptor abierto El motor est 2 Conexi n mal o defectuosa del juego de 2 Revise y repare funcionando pero no cables existe salida de AC 3 El dispositivo conectado est da ado 3 Conecte otro dispositivo que est buenas disponsible condiciones 4 Aver a en el generador 4 Contacte el Departmento de Servic
47. s que la bater a haya sido recargada Una peque a chispa puede encender el hidr geno y causar una explosi n Usted puede quedar ciego o sufrir heridas muy graves El fluido de electrolito de la bater a contiene cido y es extremadamente c ustico El contacto con el fluido de la bater a puede causar quemaduras qu micas severas No permita ninguna llama abierta chispa calor o encienda un cigarrillo durante y por varios minutos despu s de haber recargado la bater a Lleve puestos las gafas protectoras delantal y guantes de goma Portable Products by Briggs amp Stratton POWER PRODUCTS A ADVERTENCIA Los motores al funcionar producen calor La temperatura del silenciador y de las areas cercanas puede alcanzar o pasar los 150 F 65 C RY Quemaduras severas pueden ocurrir al hacer contacto No toque las superficies calientes Permita que el equipo se enfr e antes de tocarlo PRECAUCI N Las velocidades de operaci n en exceso aumentan los riesgos de heridas y da os al generador Las velocidades bajan en exceso imponen una carga muy pesada cambie ninguna velocidad determinada El generador suministra una frecuencia y un voltaje calificado cuando funciona a una velocidad determinada No modifique al generador en ninguna forma PRECAUCION El sobrepasar la capacidad del amperaje y vataje del generador puede da ar al generador y los
48. t atascada est 12 Contacte el Departmento de Servicio Briggs cerrada 13 El motor ha perdido compresi n 13 Contacte el Departmento de Servicio Briggs El motor se apaga en gasolina Llene el tanque de combustible pleno funcionamiento 2 Nivel de aceite bajo 2 Llene de caja del cig efial al nivel correcto Almoiarietince dus l Lacarga es muy alta l Vea No Sobrerecarque el Generador la potencia 3 p gina 27 2 Filtro de aire sucio 2 Reemplace el filtro de aire El El cebador fue abierto muy r pidamente Mueva el cebador a la posici n intermedia motor no funciona 5 hasta que el motor funcione suavemente continuamente o se detiene 2 Carburador con mezcla de aire combustible 2 Contacte el Departmento de Servicio Briggs muy rica o muy pobre GARANT A LIMITADA P LIZA DE GARANT A PARA LOS PROPIETARIOS DE PRODUCTOS PORT TILES GENERAC Efectiva desde el Iro de Octubre 2001 GARANTIA LIMITADA Los productos port tiles Generac LLC reparar o reemplazar sin costo alguno cualquier parte o partes del equipo que est n defectuosas en materiales o mano de obra o ambos Los cargos por concepto de transporte en las partes sometidas a reparaci n o reemplazo bajo esta garant a deben ser cubiertos por el comprador Esta garant a es efectiva por un cierto periodo de tiempo y est sujeta a las condiciones provistas en la p liza Para el servicio de garant a
49. t be exposed to excessive dust dirt moisture or any corrosive vapors Cooling air slots in the generator must not become clogged with snow leaves or any other foreign material NOTE Do Not use a garden hose to clean generator Water can enter engine fuel system and cause problems In addition if water enters generator through cooling air slots some of the water will be retained in voids and cracks of the rotor and stator winding insulation Water and dirt buildup on the generator internal windings will eventually decrease the insulation resistance of these windings To Clean the Generator CAUTION Never insert any object or tool through the air cooling slots even if the engine is not running Use a damp cloth to wipe exterior surfaces clean soft bristle brush may be used to loosen caked on dirt or oil A vacuum cleaner be used to pick up loose dirt and debris Low pressure air not to exceed 25 psi may be used to blow away dirt Inspect cooling air slots and opening on generator These openings must be kept clean and unobstructed STORAGE The generator should be started at least once every seven days and allowed to run at least 30 minutes If this cannot be done and you must store the unit for more than 30 days use the following guidelines to prepare it for storage Generator Storage Clean the generator as outlined in To Clean the Generator Check that cooling a
50. teel work correct rated frequency and voltage when running at governed Do not touch bare wires or receptacles speed Do not use generator with electrical cords which are worn Do not modify generator in any way frayed bare or otherwise damaged Do not operate generator in the rain CAUTION Do not handle generator or electrical cords while standing in Exceeding generators wattage amperage cappacity can water while barefoot or while hands or feet are wet damage generator and or electrical devices connected Do not allow unqualified persons or children to operate or to it service generator s See Don t Overload Your Generator on page 9 Start generator and let engine stabilize before connecting electrical loads Connect electrical loads in OFF position then turn ON for operation Turn electrical loads OFF and disconnect from generator before stopping generator CAUTION DANGER REC MN Improper treatment of generator can damage it and Storage batteries give off explosive hydrogen gas shorten a life during recharging Hydrogen gas stays around battery for a long time after battery has been charged If you have questions about intended use ask dealer or contact Generac Use generator only for intended uses Slightest spark will ignite hydrogen and cause explosion You can be blinded or severely injured Battery electrolyte fluid contains acid and is extremely caustic Contact with battery fluid will caus
51. terruptor Balanc n 4 Agarre la manilla de retroceso y hale lentamente hasta que puede sentir un poco de resistencia Luego hale r pidamente para encender el motor 5 Mueva la palanca de choke a la posici n Run una distancia corta a la vez por algunos segundos en un clima c lido o algunos minutos en un clima fr o Deje que el motor corra suavemente antes de cada cambio Opere con el choke en la posici n Run NOTA Si el motor a n no puede encender despu s de halarla tres veces verifique el nivel adecuado de aceite en el cig efial Esta unidad est equipada con un aparato para detectar el nivel bajo de aceite que no permitir que el motor se encienda Vea el manual del motor Consulte con el manual del propietario del motor para las instrucciones completas de encendido GENERAC Portable Products by Briggs amp Stratton POWER PRODUCTS Conexion De Cargas Electricas Deje que el motor se estabilice y se caliente por unos minutos despu s del arranque Conecte y encienda las cargas el ctricas de 120 y o 240 Voltios AC monof sicas de 60 Hz que desse No conecte cargas de 240 Voltios a tomacorrientes de 120 Voltios No conecte cargas trif sicas al generador No conecte cargas de 50 Hz al generador SOBRECARGUE EL GENERADOR Vea No Sobrecargue el Generador en la p gina 27 Parado Del Motor Desconecte todas las cargas el ctricas de los tomaco rrientes del panel
52. tials Light Bulb 75 watt 75 Deep Freezer 500 500 Sump Pump 800 1200 Refrigerator Freezer 18 Cu Ft 800 1600 Water Well Pump 1 3 HP 1000 2000 Heating Cooling Window AC 10 000 BTU 1200 1800 Window Fan 300 600 Furnace Fan Blower 1 2 HP 800 Kitchen Microwave Oven 1000 Watt 1000 Coffee Maker 1500 Electric Stove Single Element 1500 Hot Plate 2500 Family Room DVD CD Player 100 VCR 100 Stereo Receiver 450 Color Television 27 500 Personal Computer 7 monitor 800 Other Security System 180 AM FM Clock Radio 300 Garage Door Opener 2 HP 480 Electric Water Heater 40 Gallon 4000 DIY Job Site Quartz Halogen Work Light 1000 Airless Sprayer 1 3 HP 600 Reciprocating Saw 960 Electric Drill 1 2 HP 1000 Circular Saw 7 1 4 1500 Miter Saw 10 1800 Table Planer 6 1800 Table Saw Radial Arm Saw 10 2000 Air Compressor 1 1 2 HP 2500 Wattages listed are approximate only Check tool or appliance for actual wattage GENERAC Portable Products by Briggs amp Stratton POWER PRODUCTS SPECIFICATIONS Maximum Surge Watts 8 500 watts Continuous Wattage Capacity 5 500 watts Power Factor ee aa 1 0 Rated Maximum Continuous AC Load Current At 120 45 8 Amps E 240 Volts 4x te mre dicos 22 9 Amps NEE phase
53. tros Sistema de seguridad Radio Reloj AM FM Abridor de garaje 1 2 HP Calentador el ctrico de agua 40 galones Taller Luz de hal geno para trabajar Rociador sin aire 1 3 HP Sierra intercambiable Taladro el ctrico 1 2 HP Sierra circular 7 4 pulg Sierra inglete 10 pulg Mesa de planificaci n 6 pulg Sierra de mesa sierra de brazo radial 10 pulg Compresor de aire 1 1 2 HP HP Caballo de fuerza El vataje que aparece en la lista es solamente una cantidad aproximada Verifique la herramienta o aparato el ctrico para obtener el vataje verdadero GENERAC Portable Products by Briggs amp Stratton POWER PRODUCTS ESPECIFICACIONES Potencia 8 500 Vatios 8 5 kW Potencia de Sobretensi n 5 500 Vatios 5 5 kW Voltaje Nominal 120 240 Voltios Corriente M xima a 240 VoltioS 22 9 Amperios Corriente M xima a 120 VoltiosS 45 8 Amperios Frecuencia 60Hz a 3600 rpm Ao ee eae eee Monof sica Tanque del Combustible 7 Galones Americanos Peso que Embarca 2222559 a 175 lbs RECOMENDACIONES GENERALES DE MANTENIMIENTO El propietario operador es responsable por asegurarse de que todos los trabajos peri
54. ts service and replacement to perform well This warranty does not cover repair when normal use has exhausted the life of a part or the equipment Installation and Maintenance This warranty does not apply to equipment or parts that have been subjected to improper or unauthorized installation or alteration misuse negligence accident overloading overspeeding improper maintenance repair or storage so as in Generac Portable Products judgment to adversely affect its performance and reliability This warranty also does not cover normal maintenance such as adjustments fuel system cleaning and obstruction due to chemical dirt carbon or lime etc Other Exclusions Also excluded from this warranty are wear items such as quick couplers oil gauges belts o rings filters pump packing etc pumps which have been run without water supplied or damage or malfunctions resulting from accidents abuse modifications alterations or improper servicing or freezing or chemical deterioration Warranty is available only through service dealers authorized by Generac Portable Products This warranty does not apply to service by any other entity You may locate your nearest Authorized Generac Portable Product Service Dealer in our dealer locator map at www generac portables com or call 1 877 544 0982 Generac Portable Products Are Made Under One Or More Of The Following Patents Other Patents Pending 5902094 5823752 5718255 5890413 Generac Portable Prod
55. u generador por favor llame a la l nea de ayuda para generadores al 1 800 270 1408 IMPORTANTE Cualquier intento de encender el motor antes de haber colocado el aceite recomendado resultar da o del motor PARA RETIRAR EL GENERADOR DE LA CAJA e Coloque la caja sobre una superficie plana y rigida con las flechas que dicen this side up hacia arriba Abra con cuidado las tapas superiores de la caja de env o Corte de arriba a abajo las esquinas de uno de los lados de la caja y coloque ese lado de la caja sobre el suelo Retire todo el material de empaque relleno etc Saque el generador de la caja de env o Figura 10 Instale el Juego de Ruedas Tuercas Manilla Use hardware existente para conectar el lado izquierdo de pierna de apoyo a la unidad Pata de Apoyo Montajes Antivibratorios Arandela Tornillos 5500 Watt Pesado Generador CONTENIDO DE LA CAJA Revise todo el contenido Si alguna de las partes no est presente o est da ada por favor llame a la linea de ayuda para generadores al 1 800 270 1408 e La unidad principal e Manual del propietario e Aceite para motor e Tapones de fijaci n juego de llantas INSTALE EL JUEGO DE RUEDAS El juego de ruedas est disefiado para mejorar el transporte del generador NOTA Este Juego de Ruedas no ha sido dise ado para ser usado en la carretera Necesitar una llave de cubos con cubos de o 13mm y unas pi
56. ucts LLC Jefferson Wisconsin U S A