Home

GE ASM06* Air Conditioner User Manual

image

Contents

1. 2 STORM WINDOW REQUIREMENTS A storm window frame will not allow the air conditioner to tilt toward the outside and will keep it from draining properly To adjust for this attach a piece of wood to the sill WOOD PIECES WIDTH 2 LENGTH Long enough to fit inside the window frame THICKNESS To determine the thickness place a piece of wood on the sill to make it 1 2 higher than the top of the storm window frame or the vinyl frame Attach securely with nails or screws provided by the installer 1 2 higher than vinyl frame on some windows W 1 2 higher on than storm n window H frame i Storm window frame Vinyl frame 3 PREPARE AIR CONDITIONER Remove the backing from the top mounting rail seal strip and attach it to the bottom of the top mounting rail Cut to size Install the top mounting rail with 3 or 4 type A screws depending on the number of holes in the top mounting rail from the outside of the case Top mounting mounting rail Installation Instructions 3 PREPARE AIR CONDITIONER CONT C Loosen the lower screw on each side of the case and hook a security bracket on each side To allow for later adjustment do not tighten screws until installing the unit in the window Security bracket Security bracket D Insert the frames of the accordion panels into the top and bottom mounting rails Attach the accordion panels to the side of the case using 6 type A sc
2. Air conditioner freezing up The remote control is not working Water drips outside Water drips indoors Water collects in base pan El appears in the display Timer or Sleep feature not working properly Possible Causes The air conditioner is unplugged ge com What To Do Make sure the air conditioner plug is pushed completely into the outlet The fuse is blown circuit breaker is tripped e Check the house fuse circuit breaker box and replace the fuse or reset the breaker Power failure e If power failure occurs turn the air conditioner Off When power is restored wait 3 minutes to restart the air conditioner to prevent tripping of the compressor overload The current interrupter device is tripped Airflow is restricted e Press the RESET button located on the power cord plug e If the RESET button will not stay engaged discontinue use of the air conditioner and contact a qualified service technician e Make sure there are no curtains blinds or furniture blocking the front of the air conditioner The temp control may not be set correctly On models with touch pads In Cool mode press the Decrease Y pad On models with control knobs turn the temperature knob to a higher number The air filter is dirty Clean the filter at least every 30 days See the Operating Instructions section The room may have been hot When the air conditioner is
3. Room IOI1CIS It Air Cond Safety Instructions 2 3 Operating Instructions Controls Control Knobs 6 7 Controls Touch Pads 4 5 Care and Cleaning Air Filter sers sissies as 8 Batteries o oooooooomo o 8 Grille and Case 8 Outdoor Coils 8 Installation Instructions 9 12 Troubleshooting Tips 13 Normal Operating Sounds 13 Consumer Support Consumer Support 18 Product Registration 15 16 Warranty a C on het cee ete eens t 17 ENERGY STAR labeled product ENERGY STAR As an ENERGY STAR partner GE has determined that this product meets the ENERGY STAR guidelines for energy efficiency Write the model and serial numbers here Model Serial Find these numbers on a label on the side of the air conditioner ge com Owners Manual and Installation Instructions ASMO05 ASQO5 ASVO5 ASMO06 ASQO6 ASV06 ASQO8 ASVOS 49 7579 11 07 JR Safety Instructions Operating Instructions o S S S 3 S c E Troubleshooting Tips Consumer Support IMPORTANT SAFETY INFORMATION READ ALL INSTRUCTIONS BEFORE USING NY am ef si A WARNING For your safety the information in this manual must be followed to minimize the risk of fire electric shock or personal injury SAFETY PRECAUTIONS ON Use this appliance only
4. USE OF EXTENSION CORDS 115 Volt models only S Because of potential safety hazards under certain E S conditions we strongly recommend against the A CA UTI ON s S use of an extension cord DO NOT use an extension cord with any of the i 230 208 volt models However if you must use an extension cord 2 it is absolutely necessary that it be a UL isted 14 gauge wire grounding type appliance extension cord having a grounding type plug and outlet and that the electrical rating of the cord be 15 amperes minimum and 125 volts suomoanajsu Guyesadg Vile S READ AND FOLLOW THIS SAFETY INFORMATION CAREFULLY TON SAVE THESE INSTRUCTIONS A 2 2 e 3 2 S a S a sdij Burjooisa qnoa4 pioddns 10umnsuo Safety Instructions Operating Instructions Y S S S 3 Ez S S E i Troubleshooting Tips Consumer Support About the controls on the air conditioner models with touch pads Features and appearance will vary TIMER On FAN On COOL On 3 High E o U mode E Te n Jie Fea SAVER On Y ir 2 C 9 v R Te Med Saver SLEEP e reer G B Temp COOL On s ENERGY SAVER On O AS ee O ww 9 O O se e P SLEEP On c Temp ono FAN ae PA e e E B 0 Air Conditioner Controls On Off Turns air conditioner on and off Display Dis
5. en su lugar en cada lado del acondicionador de aire 5 INSTALE EL SOPORTE DE SEGURIDAD Y LA PARTE SUPERIOR DE LA ESPUMA DE LA JUNTA DE LA VENTANA A Pegue el soporte de seguridad con un tornillo tipo B Corte la parte superior de la espuma de la junta al ancho de la ventana C Rellene la espuma entre el vidrio y la ventana para evitar que aire e insectos se introduzcan en la habitaci n LE Calafatee todas las aberturas al exterior para sellar la instalaci n La instalaci n ahora est completa Instrucciones de seguridad z Instrucciones de operaci n talaci n INS o S S S S S S L9 Soluci n de problemas Apoyo al consumidor Solucionar problemas Ideas para la identificaci n y soluci n de problemas jAhorre dinero y tiempo Problema El acondicionador de aire no enciende El acondicionador de aire no enfr a como deber a El acondicionador de aire se est congelando El control remoto no funciona Hay agua goteando afuera Hay agua goteando en el interior de la habitaci n Se acumula agua en la bandeja Et aparece en la pantalla La funci n de Sincronizador Timer o Dormir Sleep no est funcionando apropiadamente 14 Causas posibles El acondicionador de aire est desconectado Qu hacer eCerci rese de que el acondicionador de aire est enchufado totalmente en el tomacorriente El fusible se dispar el cort
6. first turned on you need to allow time for the room to cool down Cold air is escaping Check for open furnace registers and cold air returns Set the air conditioner s vent to the closed position Cooling coils have iced up Ice blocks the air flow and stops the air conditioner from cooling the room The batteries are inserted incorrectly See Air conditioner freezing up below e On models with control knobs set the mode control at Fan Only and the fan switch to HI On models with touch pads set the controls at High Fan or High Cool and set the thermostat to a higher temperature e Check the position of the batteries They should be inserted in the opposite and direction The batteries may be dead Hot humid weather The air conditioner is not tilted to the outside Moisture removed from air and drains into base pan Function error code A power outage or interruption occurred Normal Operating Sounds You may hear a pinging noise caused by water being picked up and thrown against the condenser on rainy days or when the humidity is high This design feature helps remove moisture and improve efficiency You may hear the thermostat click when the compressor cycles on and off Replace the batteries e This is normal For proper water disposal make sure the air conditioner slants slightly from the case front to the rear This is normal for a short
7. for its intended purpose as described in this Owner s Manual This air conditioner must be properly installed in accordance with the Installation Instructions before it is used Never unplug your air conditioner by pulling on the power cord Always grip plug firmly and pull straight out from the receptacle Replace immediately all electric service cords that have become frayed or otherwise damaged A damaged power supply cord must be replaced with a new power supply cord obtained from the manufacturer and not repaired Do not use a cord that shows cracks or abrasion damage along its length or at either the plug or connector end HOW TO CONNECT ELECTRICITY If the receptacle does not match the plug the receptacle must be changed out by a qualified electrician Turn the unit OFF and unplug your air conditioner before making any repairs or cleaning NOTE We strongly recommend that any servicing be performed by a qualified individual For your safety do not store or use combustible materials gasoline or other flammable vapors or liquids in the vicinity of this or any other appliance All air conditioners contain refrigerants which under federal law must be removed prior to product disposal If you are getting rid of an old product with refrigerants check with the company handling disposal about what to do M MOW IU CONNEC ELECO ooo Do not under any circumstances cut or remove the third ground prong from the p
8. madera a la umbral PEDAZOS DE MADERA ANCHO 2 LONGITUD Lo suficientemente largo como para ajustar en el interior del marco de la ventana GRUESO Para determinar el grueso coloque un pedazo de madera en la umbral para hacerla 1 2 m s alta que la parte superior del marco de la ventana de tormentas o del marco vinilo P guelo firmemente con clavos o con tornillos proporcionados por el instalador 1 2 mas alto que el marco vinilo en algunas ventanas Modelos A B ASQ05 ASSO5 ASVOS 113 4 min ASO06 ASV06 13 m n ASMO5 ASMO6 13 1 2 m n ASQ08 ASV08 13 1 2 min 2 2 36 22 36 24 1 2 36 1 2 m s alto que el marco de ventana de tormentas Umbral Marco de ventana de tormentas Marco vinilo con paneles de acorde n 11 Instrucciones para la instalaci n 3 PREPARE EL ACONDICIONADOR DE AIRE A Retire la parte posterior la cinta de sellado del riel de montaje y adhi ralo al fondo del riel de montaje superior Corte al tama o apropiado Instale el riel de montaje superior con 3 o 4 tornillos tipo A dependiendo en los n meros de agujeros en el riel de montaje superior desde la parte exterior de la caja Riel de montaje q 8 9 superior Riel de X montaje YW inferior C Afloje el tornillo inferior en cada lado de la caja y enganche un soporte de seguridad en cada lado Para ajuste en el futuro no apriete los tornillos h
9. n abiertos y se encuentran retornando el aire fr o Coloque la ventanilla del acondicionador de aire en la posici n cerrada Las bobinas de enfriamiento se congelaron El hielo bloquea el flujo de aire hacia el acondicionador de aire evitando que se enfr e la habitaci n Las bater as est n insertadas incorrectamente Ver Acondicionador de aire se est congelando m s adelante En modelos con los botones de control coloque el modo de control en Fan Only Ventilador solamente y el interruptor del ventilador en HI ALTO En los modelos con teclas coloque los controles en High Fan Ventilador alto 6 High Cool Frio alto y ajuste el termostato a una temperatura m s alta Inspeccione la posici n de las bater as Deben estar insertadas en la posici n indicada y Las bater as pueden estar agotadas Tiempo h medo y caliente El acondicionador de aire no est inclinado hacia afuera La humedad removida del aire y se drena hasta la bandeja C digo de error de funci n Una p rdida en el suministro el ctrico o una interrupci n ha ocurrido Reemplace las bater as esto es normal Para drenar el agua apropiadamente cerc orese de que el acondicionador de aire est inclinado ligeramente desde el frente hacia atr s Fsto es normal por un corto per odo en reas con poca humedad normal por un per odo de tiempo m s postergado en reas m s h medas Descon
10. y un detergente suave No use cloro o materiales abrasivos Para retirarlo Agarre las orejillas en el filtro y tire hacia afuera y hacia arriba O BIEN 1 Abra la rejilla de la entrada en la parte inferior y lev ntela para retirar 2 Tire la parte superior del filtro hacia abajo y hacia afuera para retirar Instrucciones para la instalaci n D ANTES DE INICIAR Lea estas instrucciones completa y cuidadosamente IMPORTANTE Guarde estas instrucciones para uso del inspector local IMPORTANTE Observe todos los c digos y rdenes de ley Nota al instalador Aseg rese de dejar estas instrucciones con el consumidor Nota al consumidor Conserve estas instrucciones para referencia futura Nivel de destreza La instalaci n de este aparato requiere de destrezas mec nicas b sicas Tiempo de ejecuci n Aprox 1 hora Recomendamos dos personas para la instalaci n de este producto La instalaci n apropiada es la responsabilidad del instalador La falla del producto debido a una instalaci n inadecuada no est cubierta por la garant a Cuando instale este acondicionador de aire DEBE usar todas las piezas suministradas y usar procedimientos adecuados de instalaci n O REQUISITOS ELECTRICOS de 115 120 voltios de corriente alterna y 60 Hz conectados a tierra protegidos con un fusible de dilataci n de tiempo de 15 amperios o un cortacircuitos El enchufe de t
11. Care Se requiere facilitar prueba 2 x autorizados Para concertar una cita de reparaci n en l nea de la fecha de compra original G 24 horas al d a vis tenos al ge com o llame al 800 GE CARES para obtener un servicio 3 800 432 2737 Cuando llame para solicitar servicio por favor bajo la garant a XH tenga a mano el n mero de serie y el n mero de modelo Por el per odo de GE reemplazar Un a o Cualquier parte del acondicionador de aire que falle debido a defectos en los materiales o en gt A partir de la fecha la fabricaci n Durante esta garant a limitada de un a o GE tambi n proporcionar sin costo RQ de la compra original alguno toda la mano de obra y el servicio relacionado para reemplazar partes defectuosas s o 9 t9 LI o9 E z S Lo que no est cubierto 3o Viajes de servicio a su casa para mostrarle c mo Reemplazo de fusibles de la casa o reajuste del sistema funciona el equipo de circuitos Instalaci n o entrega inapropiada o mantenimiento Fallos debido a la corrosi n en modelos que no est n impropio Si usted tiene un problema durante la protegidos contra la corrosi n instalaci n o si su acondicionador de aire no tiene la capacidad de enfriamiento que usted necesita p ngase en contacto con nuestro distribuidor o instalador Usted es responsable de proporcionar las facilidades de conexi n el ctrica necesarias Da os incidentales o consecuenciales causados por defectos posibles c
12. Cool with the thermostat control at the highest number available on your knob For Quieter amp Nighttime Cooling Select Low Cool with the thermostat control at midpoint ge com Additional controls and important information Do Not Operate in Freezing Outdoor Conditions This cookonly air conditioner was not designed for freezing outdoor conditions It must not be used in freezing outdoor conditions suoyaonysuy ajes Vent Control on some models The vent control is located on the inside of the air louvers in the lower right corner When set at CLOSE only the air inside the room will be circulated and conditioned When set at OPEN some inside air is exhausted outside ee ae To open the vent push the lever to the right To close it push it to the left suoyonysuy Guyesadg Air Direction Side to Side The side to side air direction is adjusted by the louver levers X a y eo 3 a S Q S a Air Direction Up and Down on some models Fingertip pressure on the horizontal louvers adjusts the air direction up or down sdij Burjooisa qnoa pioddns sauinsuoy Safety Instructions Operating Instructions Y S S S 3 Ez S S E i Troubleshooting Tips Consumer Support Care and cleaning of the air conditioner How to Insert the Batteries on the Remote Control on some models 7 Remove the battery cover by sliding it according to the arro
13. RTANT Observe all governing codes and ordinances Note to Installer Be sure to leave these instructions with the Consumer Note to Consumer Keep these instructions for future reference Skill level Installation of this appliance requires basic mechanical skills Completion time Approximately 1 hour We recommend that two people install this product Proper installation is the responsibility of the installer Product failure due to improper installation is not covered under the Warranty You MUST use all supplied parts and use proper installation procedures as described in these instructions when installing this air conditioner ELECTRICAL REQUIREMENTS Some models require a 115 120 volt a c 2 60 Hz grounded outlet protected with a 15 amp time delay fuse or circuit breaker The 3 prong grounding plug minimizes the possibility of electric shock hazard If the wall outlet you plan to use is only a 2 prong outlet it is your responsibility to have it replaced with a properly grounded 3 prong wall outlet Some models require 230 208 volt a c GS protected with a time delay fuse or circuit breaker These models should be installed on their own single branch circuit for best performance and to prevent overloading house or apartment wiring circuits which could cause a possible fire hazard from overheating wires Air Conditioner A CAUTION Do not under any circumstances cut or remove the third g
14. a oriente el control remoto hacia el receptor de senal del acondicionador de aire El receptor de senal tiene un rango m ximo de 21 pies Este interruptor debe estar en Off Apagado para usar los ajustes del ventilador en el control de modo o Timer Sincronizador On Encendido Cuando el acondicionador de aire est apagado puede ajustarse para que se encienda autom ticamente dentro de 1 a 24 horas en el nivel previo Cada toque ajustar el tiempo en horas Off Apagado Cuando el acondicionador de aire est encendido puede ajustarse para que se apague autom ticamente dentro de 1 a 24 horas Cada toque ajustar el tiempo en horas Para cancelar el sincronizador presione la tecla Timer Sincronizador hasta que el tiempo en la pantalla desaparezca Sleep Dormir en algunos modelos Presione para que el acondicionador de aire funcione por 8 horas antes de apagarse autom ticamente Una hora despu s de que el sincronizador para dormir haya sido ajustado la temperatura seleccionada aumentar autom ticamente 2 F Para cancelar el modo de dormir presione la tecla Sleep Dormir una segunda vez Nota El sincronizador de dormir ser cancelado si cualquiera de las teclas de Timer Sincronizador Energy Saver Ahorrador de energ a o Mode Modo son presionadas Receptor de la se al del control remoto Cerci rese de que no haya nada entre el acondicionador de aire y el control remoto que pueda blo
15. a excluye el costo de env o o las visitas de servicio a su casa seuio go4d ap uoranjog Algunos estados no permiten la exclusi n o las limitaciones de dafios incidentales o consecuenciales Esta garant a da derechos legales espec ficos y usted podr a tener otros derechos que variar n de estado a estado Para saber cu les son sus derechos legales consulte a la oficina de asuntos del consumidor local o la oficina del Attorney General en su localidad Garante General Electric Company Louisville KY 40225 Jopnunsuoa je ohody 17 Apoyo al Consumidor P gina Web de GE Appliances ge com Tiene alguna pregunta sobre su electrodom stico Pruebe la p gina Web de GE Appliances 24 horas al d a cualquier d a del a o Para mayor conveniencia y servicio m s r pido ya puede descargar los Manuales de los Propietarios pedir piezas o incluso hacer una cita en l nea para que vengan a realizar una reparaci n Solicite una reparaci n ge com El servicio de expertos GE est a tan s lo un paso de su puerta Entre en l nea y solicite su reparaci n cuando le venga bien 24 horas al d a cualquier d a del a o O llame al 800 GE CARES 800 432 2737 durante horas normales de oficina Real Life Design Studio Estudio de dise o para la vida real ge com GE apoya el concepto de Dise o Universal productos servicios y ambientes que pueden usar gente de todas las edades tama os y capacidades Reconocemos la necesidad de
16. ach and return the form below to ensure that your product is registered or register online at ge com Cut here Consumer Product Ownership Registration Model Number Serial Number Mr Ms Mrs Miss Name l Name Street Address l l Apt E mail Address City State Code E d H Month l Day ly Year Number Please provide your e mail address to receive via e mail discounts special offers and other important communications from GE Appliances GEA GE Consumer amp Industrial Check here if you do not want to receive communications from GEA s carefully selected Appliances artners General Electric Company P i Louisville KY 40225 FAILURE TO COMPLETE AND RETURN THIS CARD DOES NOT DIMINISH YOUR ge com WARRANTY RIGHTS For information about GEA s privacy and data usage policy go to ge com and click on Privacy Policy or call 800 626 2224 16 GE Air Conditioner Warranty All warranty service provided by our Factory Service Centers Staple your receipt here or an authorized Customer Care technician To schedule service Proof of the original purchase on line 24 hours a day visit us at ge com or call 800 GE CARES date is needed to obtain service 800 432 2737 Please have serial number and model number under the warranty available when calling f
17. acircuitos se dispar Inspeccione los fusibles caja de interruptores de la casa y reemplace cualquier fusible o reajuste el interruptor Interrupci n en el suministro el ctrico eSi ocurre una interrupci n en el suministro el ctrico apague OFF el acondicionador de aire Cuando la energ a se restaure espere 3 minutos para reiniciar el acondicionador de aire para prevenir que se dispare el compresor por sobrecarga El dispositivo de interrupci n de corriente se ha activado ePresione el bot n RESET ubicado en el cable de alimentaci n Si el bot n RESET no se mantiene en su lugar no utilice m s el acondicionador de aire y comun quese con un t cnico calificado El flujo de aire est restringido Cerci rese de que no existe ninguna cortina persiana o mueble bloqueando el frente del acondicionador de aire El control de temperatura no En los modelos con teclado En el modo Cool Fr o est ajustado apropiadamente presione la tecla Reducir Y En los modelos con botones gire la temperatura a un n mero mayor El filtro de aire est sucio Limpie el filtro cada 30 d as por lo menos Ver la secci n de Instrucciones de Operaci n La habitaci n podr a haber estado caliente eCuando el acondicionador de aire se enciende usted necesita darle tiempo para que enfri la habitaci n El aire fr o se est escapando eCerci rese de que los registros de la calefacci n no est
18. ara o si el bot n RESET no queda enganchado deje de utilizar el acondicionador de aire y comun quese con un t cnico calificado Instrucciones para la instalaci n HERRAMIENTAS QUE USTED NECESITAR Destornillador Phillips gt L piz Regla o cinta m trica PARTES INCLUIDAS el aspecto puede variar Riel de montaje superior P Empaque superior de espuma de la ventana Cinta de sellado del riel de montaje superior Panel de acorde n izquierdo Acondicionador de aire Tornillos 1 2 Tornillos 3 4 tipo A 9 o 10 tipo B 7 E ee Tijeras o cuchilla Sello del S marco de la So e ventana Panel de acorde n derecho Soporte de seguridad 3 Instrucciones para la instalaci n 1 REQUISITOS PARA LA VENTANA e Estas instrucciones son para una ventana est ndar de dos pliegues Usted necesitar modificar el proceso para otros tipos de ventanas Todas las partes de apoyo deben quedar totalmente aseguradas a alg n metal mamposter a o a la madera e El tomacorriente el ctrico debe estar al alcance del cable el ctrico del acondicionador de aire e Siga las dimensiones de la tabla y la ilustraci n seg n su modelo 2 REQUISITOS DE UNA VENTANA DE TORMENTAS Un marco de ventana de tormentas no permitir que el acondicionador de aire se incline hacia el exterior y evitar que drene apropiadamente Para solucionar este problema adhiera un pedazo de
19. as est ajustado en Cool Fr o tomar aproximadamente 3 minutos para que el compresor comience a enfriar otra vez Modo de Fan Ventilador Use el Fan Ventilador en High 3 Alto Med 2 Medio o Low 1 Bajo para proporcionar circulaci n de aire y filtraci n sin enfriamiento Debido a que los niveles de Control de la ventilaci n en algunos modelos El control de ventilaci n est localizado al interior de las persianas en la esquina derecha inferior Cuando est ajustado en CLOSE CERRADO solamente el aire en el interior de la habitaci n circular y se acondicionar Cuando est ajustado en OPEN ABIERTO un poco del aire interno es expelido hacia afuera restablecida Las funciones del Sincronizador y Dormir reajustar al ajuste original Es posible que usted necesite ajustar un tiempo nuevo si as lo desea Descripciones de enfriamiento Para enfriamiento normal Seleccione el modo de Cool Frio y ventilador High 3 Alto o Med 2 Medio con una temperatura de ajuste media Para enfriamiento maximo Seleccione el modo de Cool Frio y ventilador High 3 Alto con una temperatura de ajuste menor Para enfriamiento silencioso y enfriamiento nocturno Seleccione el modo de Cool Fr o y ventilador Low 1 Bajo con una temperatura de ajuste media NOTA Si cambia de un ajuste Cool Fr o a Off Apagado o a un ajuste de ventilador espere aproximadamente 3 minutos antes de cambiar ot
20. as provided in this Limited Warranty Any implied warranties including the implied warranties of merchantability or fitness for a particular purpose are limited to one year or the shortest period allowed by law This warranty is extended to the original purchaser and any succeeding owner for products purchased for home use within the USA If the product is located in an area where service by a GE Authorized Servicer is not available you may be responsible for a trip charge or you may be required to bring the product to an Authorized GE Service location for service In Alaska the warranty excludes the cost of shipping or service calls to your home Some states do not allow the exclusion or limitation of incidental or consequential damages This warranty gives you specific legal rights and you may also have other rights which vary from state to state To know what your legal rights are consult your local or state consumer affairs office or your states Attorney General Warrantor General Electric Company Louisville KY 40225 17 suoi anijsu Ajojeg suoioanajsu bunesado 2 2 y e 3 2 S a S a sdij Burjooisa qnoa pioddns sauinsuoy Consumer Support GE Appliances Website ge com Have a question or need assistance with your appliance Try the GE Appliances Website 24 hours a day any day of the year For greater convenience and faster service you can now download Owner s Manuals order parts or even sched
21. asher and dryer range TV VCR and much more any brand Plus there s no extra charge for emergency service and low monthly financing is available Even icemaker coverage and food spoilage protection is offered You can rest easy knowing that all your valuable household products are protected against expensive repairs Place your confidence in GE and call us in the U S toll free at 800 626 2224 for more information All brands covered up to 20 years old in the continental U S Please place in envelope and mail to Warranty Registration Department P O Box 32150 Louisville KY 40232 2150 General Electric Company 15 Consumer Product Ownership Registration Dear Customer Thank you for purchasing our product and thank you for placing your confidence in us We are proud to have you as a customer Follow these three steps to protect your new appliance investment Complete and mail After mailing the Read your Owner s your Consumer registration below Manual carefully Product Ownership store this document It will help you Registration today in a safe place It operate your new Have the peace of contains information appliance properly mind of knowing we you will need should can contact you in you require service the unlikely event of a Our service number is safety modification 800 GE CARES 800 432 2737 Model Number Serial Number Important If you did not get a registration card with your product det
22. asta que la instalaci n de la unidad en la ventana Soporte de seguridad S Soporte de seguridad B PREPARE EL ACONDICIONADOR DE AIRE CONT D Inserte los marcos de los paneles de acorde n en la parte superior e inferior de los rieles de montaje Adhiera los paneles de acorde n al lado de la caja usando los 6 tornillos tipo A Riel de montaje superior Paneles de acorde n 4 INSTALE EL ACONDICIONADOR DE AIRE EN LA VENTANA A Corte la banda de sello de la ventana de acuerdo con el ancho de la ventana y p guela del lado adhesivo al fondo de la banda ay Sello de la banda de ventana Coloque el acondicionador de aire en la umbral con el riel de montaje inferior contra su extremo posterior C ntrelo y cierre la ventana firmemente detr s del riel de montaje superior Debe estar nivelado o ligeramente inclinado hacia el exterior Use un nivel una inclinaci n de 1 3 de burbuja ser la correcta hacia el exterior Instrucciones para la instalaci n 4 INSTALE EL ACONDICIONADOR DE AIRE EN LA VENTANA CONT C Extienda los paneles de acorde n izquierdo y derecho hacia las bandas de la ventana vertical con 4 tornillos tipo B Tornillos tipos B Tornillo bh tipo B D Pegue los corchetes a la umbral en ambos lados usando dos tornillos tipo B E Apriete los tornillos para sujetar los soportes
23. bles NO USE un cable de extensi n con ninguno de los de extensi n modelos de 230 208 voltios MIDES ap s uorn nysuj Sin embargo si usted se ve en la necesidad de usar un cable el ctrico de extensi n es absolutamente necesario que el mismo est listado bajo UL calibre 14 de tipo 3 tomas con conexi n a tierra para electrodom sticos y el ndice debe ser de 15 amperios m nimo y 125 voltios uoiesado s ap SALOIIINHSUJ Vis N DA LEA Y SIGA ESTAS INSTRUCCIONES DE SEGURIDAD CUIDADOSAMENTE CON GUARDE ESTAS INSTRUCCIONES esuli N E S IAE O 0 S e seuio go4d ap uoronjog Jopnunsuoa je ohody Instrucciones de seguridad L9 Instrucciones de operaci n talaci n INS o S 4 S S S S 3 s7 Soluci n de problemas Apoyo al consumidor Acerca de los controles en el acondicionador de aire modelos con teclas de toque Las funciones y el aspecto pueden variar AHORRADOR DE ENERGIA Encendido DORMIR Encendido VENTILADOR Encendido SINCRONIZADOR FR O Encendido Encendido Cool EA ner Saver J AHORRADOR DE ENERGIA Encendido Low DORMIR Encendido VENTILADOR a 2 e 3 High Fon 2 Med SINCRONIZADOR o A JM Encendido TEME J O Ww rJ 1 9 FAN 0D COOL Q m O oA lt gt ao FAN ERCULARE A ep Control remoto Contr
24. dise ar para una gran gama de habilidades y dificultades f sicas y mentales Para m s detalles cobre las aplicaciones de GE Dise o Universal incluyendo ideas de dise o para la cocina para personas con discapacidades mire nuestra p gina Web hoy mismo Para personas con dificultades auditivas favor de llamar al 800 TDD GEAC 800 833 4322 Garant as ampliadas ge com Compre una garant a ampliada y obtenga detalles sobre descuentos especiales disponibles mientras su S garant a est a n activa Puede comprarla en l nea en cualquier momento o llamar al 800 626 2224 durante horas normales de oficina GE Consumer Home Services estar a n ah cuando su garant a termine Plezas y accesorios ge com Aquellos individuos con la calificaci n necesaria para reparar sus propios electrodom sticos pueden pedir que se les manden las piezas o accesorios directamente a sus hogares aceptamos las tarjetas VISA MasterCard y Discover Haga su pedido en l nea hoy 24 horas cada d a o llamar por tel fono al 800 626 2002 durante horas normales de oficina Las instrucciones descritas en este manual cubren los procedimientos a seguir por cualquier usuario Cualquier otra reparaci n deber a por regla general referirse a personal calificado autorizado Debe ejercerse precauci n ya que las reparaciones incorrectas pueden causar condiciones de funcionamiento inseguras P ngase en contacto con nosotros ge com KoA Si no esta satisfec
25. e ENERGY STAR relativas al rendimiento energ tico Escriba el modelo y n mero de serie aqu N mero de modelo N mero de serie Usted puede encontrar estos n meros al costado del acondicionador de aire 49 7579 Manual del Propietario e Instrucciones de Instalacion 11 07 JR Instrucciones de seguridad s7 Instrucciones de operaci n talaci n INS o S e S S S S 3 s7 Soluci n de problemas Apoyo al consumidor INFORMACI N IMPORTANTE DE SEGURIDAD LEA TODAS LAS INSTRUCCIONES ANTES DE USAR vie PRECAUCIONES DE SEGURIDAD On A ADVERTENCIA Por su seguridad se debe seguir la informaci n en este manual para minimizar el riesgo de incendios descargas el ctricas o lesiones personales Use este electrodom stico solamente para el prop sito determinado seg n se describe en el Manual del propietario Este acondicionador de aire debe instalarse correctamente de acuerdo con las Instrucciones de instalaci n antes de su uso Nunca desenchufe su acondicionador de aire tirando del cable el ctrico Siempre agarre firmemente el enchufe y tire de l directamente hacia afuera Reemplace inmediatamente todos los cables el ctricos que se hayan pelado o que se hayan da ado de alguna otra manera Un cable de corriente da ado no debe repararse sino que debe ser sustituido por uno nuevo que se adquiera del fabricante No use un cable el ctrico que
26. ears Oo Sleep on some models Press to set the air conditioner to run for 8 hours before it automatically shuts off One hour after the sleep timer is set the set temperature will automatically increase 2 F To cancel the sleep mode press the Sleep pad a second time Note The sleep timer will be cancelled if the Timer Energy Saver or Mode pad is pressed Q Remote Control Signal Receiver Make sure nothing is between the air conditioner and the remote control that could block the signal Make sure batteries are fresh and installed correctly see the Care and Cleaning section Additional controls and important information Do Not Operate in Freezing Outdoor Conditions This cookonly air conditioner was not designed for freezing outdoor conditions It must not be used in freezing outdoor conditions When the air conditioner is turned on it will automatically start in the setting last used Power Outage Recovery Feature In the case of a power outage or interruption the unit will automatically re start in the settings last used after the power is restored The Timer and Cool Mode Use the Cool mode with High 3 Med 2 or Low 1 fan for cooling Use the Increase A Decrease Y pads to set the desired temperature between 64 F and 86 F in 1 F increments A thermostat is used to maintain the room temperature The compressor will cycle on and off to keep the room at the set level of comfort Set the therm
27. ecte el acondicionador de aire Espere 3 minutos y ench felo otra vez En el caso de una p rdida del suministro el ctrico o una interrupci n la funciones de Sincronizador y Dormir en la unidad se reajustar al ajuste original Es posible que usted necesite ajustar un tiempo nuevo si as lo desea los d as lluviosos o cuando la humedad es alta Esta gotear desde el lado externo de la unidad caracter stica de dise o ayuda a remover la humedad y mejora la eficiencia ge com a Sonidos de operaci n normales Sa Quiz s escuche un sonido met lico causado por El agua se acumula en la bandeja durante d as lluviosos a S el agua tomada y tirada contra el condensador en o con mucha humedad El agua podr a derramarse y S 2 Q El ventilador podr a funcionar aun si el compresor no lo hace ap sau Quiz s escuche que el termostato hace clic cuando el compresor hace ciclo entre encendido y apagado sa uoielado ap sauoi22nijsu N gt 9 UR n S at O 2 96 D a e MI OQ b 3 0 e sa MEE MTS Jopnunsuoa je ohody 15 Notas 16 pepunbas uoiaeiado UOI20 0 SUI ap sauoiaanujsu ap sauoi22nujsu ap sauoiaanijsu sewajqoid ap uoranjog 1opnunsuoo je oAody Garant a de su acondicionador de aire de GE a Todos los servicios de garant a los proporcionan nuestros Centros Grape aqu su recibo S s d ig de Reparaci n de F brica o nuestros t cnicos Customer
28. ho con el servicio que recibe de GE pongase en contacto con nosotros en nuestra pagina Web indicando todos los detalles asi como su numero de tel fono o escribanos a General Manager Customer Relations GE Appliances Appliance Park Louisville KY 40225 Registre su electrodom stico ge com Registre su nuevo electrodom stico en l nea cuando usted prefiera El registrar su producto a tiempo le proporcionar si surgiera la necesidad una mejor comunicaci n y un servicio m s r pido bajo los t rminos de su garant a Tambi n puede enviar su tarjeta de registro pre impresa que se incluye en el material de embalaje o recorte y use el formulario de este Manual del Propietario 18 Impreso en China
29. itivo para interrupci n de corriente Se incluye un bot n de prueba y de reinicio en el dispositivo El dispositivo debe ponerse a prueba peri dicamente primero se presiona el bot n de TEST prueba y luego RESET reinicio mientras se encuentra enchufado al tomacorriente Si el bot n TEST no se dispara o si el bot n RESET no queda enganchado deje de utilizar el acondicionador de aire y comun quese con un t cnico calificado Pida a un t cnico que inspeccione el tomacorriente y el circuito para cerciorarse de que el tomacorriente est conectado a tierra de la manera apropiada Donde exista un tomacorriente de dos tomas es su responsabilidad y obligaci n personal hacer que dicho tomacorriente sea reemplazado por uno de tres tomas con conexi n a tierra El acondicionador de aire deber a siempre estar conectado a un tomacorriente individual con su circuito de voltaje correspondiente Esto proporciona el mayor rendimiento y adem s evita que los circuitos del resto de la casa se sobrecarguen lo cual podr a causar incendios por el sobrecalentamiento del cableado Ver las Instrucciones de instalaci n en la secci n Requisitos El ctricos para los requisitos espec ficos de conexi n ge com A ADVERTENCIA USO DE CABLES DE EXTENSI N Modelos de 115 voltios solamente om Debido al potencial de riesgos de seguridad A PREC A UCI N bajo ciertas condiciones en rgicamente recomendamos contra el uso de ca
30. l de Mode Temp del ajuste Cool hacia el ajuste Fan Only espere por lo menos 3 minutos antes de cambiar otra vez a un ajuste Cool enfriamiento o S 4 S S S S 3 Con tri oles en algunos modelos s7 Soluci n de problemas Thermostat Med Cool o Control de Mode Modo NOTA uacua ajuste Cool Fr o h Off ind oa P un ajuste de ventilador espere aproximadamente 3 minutos Pn P epe Coo Fre Boot urs A i i las antes de cambiar otra vez al ajuste de Cool Fr o velocidades del ventilador varias Use el Low Fan Ventilador Bajo o Hi Fan Ventilador Alto para proporcionar circulaci n de aire y filtraci n sin enfriamiento Descripciones de enfriamiento Para enfriamiento normal Seleccione el modo de Hi Cool Fr o Alto o Med Cool Fr o Medio con el termostato a un ajuste medio 6 Control de Termostato Para enfriamiento m ximo Seleccione el modo de Hi Cool Fr o Alto con el termostato a un n mero m s alto Se usa un termostato para mantener la temperatura de la habitaci n El compresor har ciclo entre Para enfriamiento silencioso y enfriamiento nocturno apagado y encendido para mantener la habitaci n Seleccione el modo de Low Cool Fr o Bajo con el a la temperatura deseada Ajuste el termostato a un termostato a un ajuste medio numero mayor y el aire interno se enfriar m s Si lo ajusta a un n mero menor la temperatura del 6 aire interno se calentar m s Apoyo al cons
31. luci n de problemas Apoyo al consumidor Cuidado y limpieza del acondicionador de aire C mo insertar las bater as del control remoto en algunos modelos 7 Retire la cubierta de la bater a desliz ndola de acuerdo con la direcci n de la flecha 2 Inserte bater as nuevas cercior ndose de que los polos positivos y negativos est n orientados correctamente 3 Coloque la cubierta otra vez desliz ndola en su lugar Parrilla y caja Apague el acondicionador de aire y retire el enchufe del tomacorriente de la pared antes de limpiar Bobinas para exteriores Las bobinas en el lado exterior del acondicionador de aire debe ser inspeccionada regularmente Si la misma est obstruida con suciedad u holl n podria ser limpiada profesionalmente Filtro de aire El filtro de aire detr s de la rejilla frontal debe inspeccionarse y limpiarse por lo menos cada 30 d as o m s a menudo si fuese necesario Limpie el filtro con agua tibia y jab n Enju guelo y permita que se seque antes de colocarlo otra vez en su lugar A PRECA UCION NO OPERE el acondicionador de aire sin el filtro debido a que la suciedad y las pelusas lo obstruir n y reducir n su rendimiento NOTAS Use 2 bater as AAA de 1 5 voltios No use bater as recargables Retire las bater as del control remoto si el sistema no ha de ser usado por un per odo de tiempo extenso Para limpiar use agua
32. muestre evidencias de deterioro o da os de abrasi n en su superficie en alguno de sus extremos Si el recept culo no coincide con el enchufe un electricista calificado debe reemplazar el recept culo Apague la unidad y desenchufe su acondicionador de aire antes de hacer cualquier reparaci n o limpiar NOTA Recomendamos en rgicamente que cualquier servicio llevado a cabo en este equipo lo realice un individuo calificado Por su seguridad no almacene ni use materiales combustibles gasolina u otros vapores o l quidos inflamables en la proximidad de ste o alg n otro electrodom stico Todos los acondicionadores de aire contiene refrigerantes los que por Ley Federan deben ser removidos antes de desecharlos Si usted planea deshacerse de alg n producto que contenga refrigerantes p ngase en contacto con la compa a que se encarga de recoger su basura para que le indiquen qu hacer AT C MO CONECTAR LA ELECTRICIDAD Bajo ninguna circunstancia corte o remueva la tercera p a tierra del cable el ctrico En pos de la seguridad personal este electrodom stico debe siempre conectarse a tierra NO use un enchufe adaptador con este electrodom stico El cable el ctrico de este electrodom stico est equipado con un enchufe de tres p as tierra que combina con un tomacorriente est ndar de tres tomas de pared para minimizar la posibilidad de una descarga el ctrica El cable el ctrico incluye un dispos
33. ntain the room temperature The compressor will cycle on and off to keep the room at the same level of comfort When you turn the knob to a higher number the indoor air will become cooler Turn the knob to a lower number and the indoor air will become warmer Appearance will vary About the controls on the air conditioner models with control knob s Features and appearance may vary Fan Only the knob counterclockwise toward the smaller blue area for the indoor air to become warmer The Mode Temp control is used to maintain the room temperature When set in a Cool mode the compressor will cycle on and off to keep the room at the same level of comfort Cooling Descriptions For Normal Cooling Select a Cool mode with the Mode Temp knob set at the midpoint For Maximum Cooling Select a Cool mode with the Mode Temp knob set toward the larger blue area For Quieter amp Nighttime Cooling Select a Cool mode with the Mode Temp knob set toward the smaller blue area NOTE If you move the Mode Temp control knob from a Cool setting to the Fan Onlysetting wait at least 3 minutes before switching back to a Cool setting Thermostat NOTE If you move the switch from a cool setting to OFF or to a fan setting wait at least 3 minutes before switching back to a cool setting Cooling Descriptions For Normal Cooling Select Hi Cool or Med Cool with the thermostat control at midpoint For Maximum Cooling Select Hi
34. oles del acondicionador de aire Q On Off Encendido apagado Apaga y prende el acondicionador de aire Pantalla Muestra la temperatura de ajuste o el tiempo restante en el sincronizador Modo Usado para ajustar el acondicionador de aire al modo Cool Fr o o Fan Ventilador Teclas de Aumentar A Reducir V Usado para ajustar la temperatura cuando se encuentre en el modo Cool Fr o Fan Ventilador o Usado para ajustar la velocidad del ventilador a Low Bajo Med Medio o High Alto Circulaire Circulador de aire en algunos modelos Para proporcionar circulaci n de aire continua de lado a lado ajuste el interruptor de Circulaire en On Encendido Para lograr circulaci n de aire fija de lado a lado coloque en On Encendido hasta que la circulaci n de aire deseada sea lograda luego coloque en Off Apagado Energy Saver Ahorrador de energ a e Controla el ventilador On Encendido El ventilador y el compresor hacen ciclo en encendido y apagado Este resulta en variaciones mayores en la temperatura de la habitaci n y en la humedad Normalmente usado cuando la habitaci n no est ocupada Mota El ventilador continuar funcionando por un corto tiempo despu s de que el compresor haya entrado en el ciclo de apagado Off Apagado E ventilador funciona todo el tiempo mientras que el compresor pasa por los ciclos de encendido y apagado Control remoto Para garantizar una operaci n apropiad
35. on este acondicionador de aire Da o al producto causado por voltaje inapropiado hacia el equipo accidentes incendios inundaciones o actos de la naturaleza de fuerza mayor psu 0193N 1 Fallo del producto resultante de modificaciones al producto o debido a uso irrazonable incluyendo no Da os despu s de la entrega proporcionar mantenimiento razonable y necesario sa ap sau a A 2 Q e 3 Producto no accesible para facilitar el servicio requerido En locales comerciales la mano de obra necesaria para retirar la unidad hacia un lugar para revisi n por parte de un t cnico individual EXCLUSI N DE GARANT AS IMPL CITAS Su nico y exclusivo derecho es la reparaci n del producto tal y como se indica en esta Garant a limitada Cualquier garant a impl cita incluyendo las garant as impl citas de sa comerciabilidad o adecuaci n para un fin determinado est n limitadas a un a o o el per odo de tiempo m s breve permitido por la ley Esta garant a se extiende al comprador original y cualquier comprador posterior de productos comprados para uso residencial dentro de Estados Unidos Si el producto est situado en un rea que no dispone de servicio por parte de un proveedor de servicio autorizado de GE podr a tener que hacerse cargo de los costes de env o o bien podr a solicit rsele que lleve el producto a una centro de servicio de GE autorizado para realizar la reparaci n En Alaska la garant
36. or se caliente m s z operaci n NOTA Si el acondicionador de aire est apagado y entonces es encendido mientras est en un modo Cool Enfriado el compresor necesitar aproximadamente 3 minutos para iniciar y para que el enfriamiento comience Instrucciones de El control de Mode Temp es usado para mantener a 6 Interrup tor de Fan Ventilador temperatura ambiente Cuando est colocado en el modo Cool fen algunos modelos Enfriado el compresor har ciclo entre apagado y encendido Use esta funci n para cambiar la velocidad del ventilador para mantener el sal n al mismo nivel de temperatura entre LO BAJO HI ALTO Descripciones de enfriamiento Para enfriamiento normal Seleccione un modo Cool Enfriado con el bot n Mode Temp en la posici n del centro Para enfriamiento m ximo Seleccione un modo Cool Enfriado Control de Mode Temp Modo Temp en algunos modelos Use para ajustar el acondicionador de aire al modo Fan Only Ventilador solamente o a un modo S Q S Cool Enfriado i el pus Mode Temp nd us el ris u mayor ara enfriamiento m s tranquilo amp durante las noches Seleccione S Modo de Fan Only Ventilador solamente un modo Cool Enfriado con el bot n Mode Temp apuntando YN Use Fan Only en HI ALTO o LO BAJO Fan Ventilador hacia el rea azul m s peque a S para proporcionar circulaci n de aire y filtraci n sin NOTA Si usted mueve el bot n de contro
37. or service For The Period Of GE Will Replace One Year Any part of the air conditioner which fails due to a defect in materials or workmanship From the date of the During this limited one year warranty GE will also provide free of charge all labor and related original purchase service to replace the defective part What Is Not Covered Service trips to your home to teach you how to Replacement of house fuses or resetting of circuit use the product breakers Improper installation delivery or maintenance If you Failure due to corrosion on models not corrosion have an installation problem or if the air conditioner protected is of improper cooling capacity for the intended use contact your dealer or installer You are responsible for providing adequate electrical connecting facilities Damage to the product caused by improper power supply voltage accident fire floods or acts of God Incidental or consequential damage caused by possible Failure of the product resulting from modifications to defects with this air conditioner the product or due to unreasonable use including failure to provide reasonable and necessary maintenance Damage caused after delivery In commercial locations labor necessary to move Product not accessible to provide required service the unit to a location where it is accessible for service by an individual technician EXCLUSION OF IMPLIED WARRANTIES Your sole and exclusive remedy is product repair
38. ore switching back to a Cool setting fan only settings do not provide cooling a temperature setting will not be displayed ee To open the vent push the lever to the right To close it push it to the left suoi anijsu ajes suononysuy Guyesadg 2 2 y e 3 2 S Q S a sdij 6unooysa qno pioddns sauinsuoy Safety Instructions Operating Instructions o S S S S S Troubleshooting Tips Consumer Support Controls on models so equipped ON OFF Switch Turns air conditioner on and off NOTE If the air conditioner is off and is then turned on while set in a Cool mode it will take approximately 3 minutes for the compressor to start and cooling to begin Fan Switch on some models Use to set the fan speed to LO or HI o Mode Temp Control on some models Use to set the air conditioner to the Fan Only or a Cool mode Fan Only Mode Use Fan Only at Hl or LO Fan to provide air circulation and filtering without cooling Cool Mode Use a Cool setting with HI or LO Fan for cooling Turn the knob clockwise toward the larger blue area for the indoor area to become cooler Turn Con tr ols on models so equipped Med Cool Mode Control Hi Cool Med Cool and Low Cool provide cooling with different fan speeds Low Fan or Hi Fan provides air circulation and filtering without cooling Thermostat Control The thermostat control is used to mai
39. ostat at a lower number and the indoor air will become cooler Set the thermostat at a higher number and the indoor air will become warmer NOTE If the air conditioner is off and is then turned on while set to Cool it will take approximately 3 minutes for the compressor to start and cooling to begin Fan Mode Use the Fan at High 3 Med 2 or Low 1 to provide air circulation and filtering without cooling Since Vent Control on some models The vent control is located on the inside of the air louvers in the lower right corner When set at CLOSE only the air inside the room will be circulated and conditioned When set at OPEN some inside air is exhausted outside Air Direction Up and Down on some models Fingertip pressure on the horizontal louvers adjusts the air direction up or down Air Direction Side to Side on some models The side to side air direction is adjusted by the louver levers ge com Sleep features will reset to the original setting You may need to set a new time if desired Cooling Descriptions For Normal Cooling Select the Cool mode and High 3 or Med 2 fan with a middle set temperature For Maximum Cooling Select the Cool mode and High 3 fan with a lower set temperature For Quieter amp Nighttime Cooling Select the Cool mode and Low 1 fan with a middle set temperature NOTE If you switch from a Cool setting to Off or to a fan setting wait at least 3 minutes bef
40. ower cord For personal safety this appliance must be properly grounded DO NOT use an adapter plug with this appliance The power cord of this appliance is equipped with a 3 prong grounding plug which mates with a standard 3 prong grounding wall outlet to minimize the possibility of electric shock hazard from this appliance Power cord includes a current interrupter device A test and reset button is provided on the plug case The device should be tested on a periodic basis by first pressing the TEST button and then the RESET button while plugged into the outlet If the TEST button does not trip or if the RESET button will not stay engaged discontinue use of the air conditioner and contact a qualified service technician Have the wall outlet and circuit checked by a qualified electrician to make sure the outlet is properly grounded Where a 2 prong wall outlet is encountered it is your personal responsibility and obligation to have it replaced with a properly grounded 3 prong wall outlet The air conditioner should always be plugged into its own individual electrical outlet which has a voltage rating that matches the rating plate This provides the best performance and also prevents overloading house wiring circuits which could cause a fire hazard from overheated wires See the Installation Instructions Electrical Requirements section for specific electrical connection requirements ge com e o A WARNING Ed
41. period in areas with little humidity normal for a longer period in very humid areas Unplug the air conditioner Wait 3 minutes and plug it back in n the case of a power outage or interruption the unit Timer and Sleep features will reset to the original setting You may need to set a new time if desired Water will collect in the base pan during high humidity or on rainy days The water may overflow and drip from the outdoor side of the unit The fan may run even when the compressor does not 13 suoyonysuy Ajajeg suoijanijsu bunesado 2 2 e 3 2 S a S 7 sdij bunooysa qno yioddngs saunsuoy 14 yioddng Jaunsuos v suononysuy Ajojeg suoyonysuj Gunesadg suononsuj uone je3suj sdij Guyooysajqnouy GE Service Protection Plus GE a name recognized worldwide for quality and dependability offers you Service Protection Plus comprehensive protection on all your appliances No Matter What Brand Benefits Include We Il Co ver Any Appliance Backed by GE gt e All brands covered A nywher e Anytime T Unlimited service calls All parts and labor costs included No out of pocket expenses No hidden deductibles One 800 number to call You will be completely satisfied with our service protection or you may request your money back on the remaining value of your contract No questions asked It s that simple Protect your refrigerator dishwasher w
42. plays the set temperature or time remaining on timer Mode Use to set the air conditioner to Cool or Fan mode Increase A Decrease Y Pads Use to set temperature when in Cool mode Fan Use to set the fan speed at Low Med or High Circulaire on some models Turn on to provide continuous side to side air circulation For fixed side to side air direction turn On until the desired air direction is obtained then turn it Off Energy Saver Controls the fan On The fan and compressor cycle on and off This results in wider variations of room temperature and humidity Normally used when the room is unoccupied Note The fan will continue to run for a short time after the compressor cycles off Off The fan runs all the time while the compressor cycles on and off This switch must be set at Offin order to use the fan settings on the mode control Remote Control To ensure proper operation aim the remote control at the signal receiver on the air conditioner The remote control signal has a range of up to 21 feet Remote Control Timer n When the air conditioner is off it can be set to automatically turn on in 1 to 24 hours at its previous setting Fach touch will set the time in hours Off When the air conditioner is on it can be set to automatically turn off in 1 to 24 hours Each touch will set the time in hours To cancel the timer press the Timer pad until the display time disapp
43. quear la senal Cerci rese de que las bater as sean frescas y se instalen correctamente ver la Secci n de Cuidado y Limpieza Controles adicionales e informaci n importante No use en las condiciones externas debajo el punto de congelaci n Este acondicionador de aire no es dise ado para usar en temperaturas externas debajo el punto de congelaci n No use en las condiciones externas debajo el punto de congelaci n Cuando el acondicionador de aire se encienda se encender autom ticamente en el nivel que se encontraba la ltima vez ge com Funci n de recuperaci n de p rdida de energ a En caso de la p rdida de la energ a o interrupci n la unidad reiniciar autom ticamente en las funciones de la ltima vez que fue usado una vez la energ a sea Modo Cool Fr o Use el modo Cool con ventilador High 3 Alto Med 2 Medio o Low 1 Bajo para enfriar Use las teclas de Increase A Aumentar Decrease W Reducir para ajustar a la temperatura deseada entre 64 F y 86 F en incrementos de 1 F Se usa un termostato para mantener la temperatura de la habitaci n El compresor har ciclo entre apagado y encendido para mantener la habitaci n a la temperatura deseada Ajuste el termostato a un n mero menor y el aire interno se enfriar m s Si lo ajusta a un n mero mayor la temperatura del aire interno se calentar m s NOTA Si el acondicionador de aire est apagado y luego se enciende mientr
44. ra vez al ajuste de Cool Fr o ventilador nicamente no proporcionan enfriamiento el nivel de temperatura no se muestra en la pantalla D Para abrir la parrilla empuje la palanca hacia la derecha y para cerrarla hacia la izquierda Direccion del aire Hacia arriba y hacia abajo en algunos modelos Una presi n sencilla con los dedos en las persianas horizontales ajustar la direcci n del aire hacia arriba o hacia abajo Direcci n del aire de lado a lado en algunos modelos La direcci n de lado a lado del aire es ajustada por las palancas de las persianas SuJ pepunBas 01221 ap sau Pa uoielado ESE 0193N 19SU ap sau wn 2 ty Q Q 3 4a seuia go4d ap uoronjog Jopnunsuoa je ohody Acerca de los controles en el acondicionador de aire modelos con bot n es de control Las funciones y el aspecto pueden variar Fan Only Instrucciones de seguridad el aspecto puede variar Con tri oles en algunos modelos Interruptor ON OFF Modo de Cool Enfriado Enciende y apaga el acondicionador de aire Use un ajuste Cool con HI ALTO o LOW BAJO Fan Ventilador para enfriamiento Gire el bot n en el sentido de las agujas del reloj hacia el rea azul mayor para que el aire de interior se enfr e m s Gire el bot n en sentido contrario al de las agujas del reloj hacia el rea azul m s peque a para que el aire de interi
45. res p as con conexi n a tierra minimiza la posibilidad de descargas el ctricas Si el tomacorriente de la pared que usted planea usar solamente tiene 2 tomas es su responsabilidad hacer que un t cnico lo reemplace por uno de tres tomas con conexi n a tierra O Algunos modelos requieren tomacorrientes Acondicionador de aire REQUISITOS ELECTRICOS cont Algunos modelos requieren 230 208 voltios 3 de corriente alterna protegidos por un fusible de dilataci n de tiempo o un cortacircuitos Estos modelos deber an instalarse en un ramal exclusivo del circuito para un rendimiento m s notable y para prevenir sobrecargas en los circuitos de cableados de su casa o apartamento lo cual podr a representar un riesgo de incendio por el sobrecalentamiento de los alambres A PRECAUCI N Bajo ninguna circunstancia corte o remueva la tercera p a conexi n a tierra del cable el ctrico No cambie el enchufe en el cable el ctrico de este acondicionador de aire Los cables caseros de aluminio podr an presentar problemas especiales Consulte a un t cnico electricista calificado El cable de alimentaci n incluye un dispositivo para interrupci n de corriente Se incluye un bot n de prueba y de reinicio en el dispositivo El dispositivo debe ponerse a prueba peri dicamente primero se presiona el bot n de TEST prueba y luego RESET reinicio mientras se encuentra enchufado al tomacorriente Si el bot n TEST no se disp
46. rews Top mounting rail Accordion panels 4 INSTALL AIR CONDITIONER IN WINDOW Cut the window sash seal to the window width and stick the adhesive side to the bottom of the sash LN Window sash seal B Place the air conditioner on the sill with the bottom mounting rail against its back edge Center it and close the window securely behind the top mounting rail It should be level or slightly tilted to the outside Use a level about a 1 3 bubble will be the correct case slant to the outside 4 INSTALL AIR CONDITIONER IN WINDOW CONT Extend the left and right accordion panels to the vertical window sashes and attach with 4 type B screws D Attach the brackets to the sill on both sides using two type B screws E Tighten the screws to secure the brackets in place on each side of the air conditioner 5 INSTALL SECURITY BRACKET AND FOAM TOP WINDOW GASKET A Attach a security bracket with a type B screw Cut the foam top window gasket to the window width C Stuff the foam between the glass and the window to prevent air and insects from getting into the room Caulk or weather strip any gaps or openings to the outside to seal the installation The installation is now complete Troubleshooting Tips Problem Air conditioner does not start Air conditioner does not cool as it should
47. round prong from the power cord Do not change the plug on the power cord of this air conditioner Aluminum house wiring may present special problems consult a qualified electrician TOOLS YOU WILL NEED Phillips head screwdriver a Pencil Ruler or tape measure Scissors or knife Power cord includes a current interrupter device A test and reset button is provided on the plug case The device should be tested on a periodic basis by first pressing the TEST button and then the RESET button while plugged into the outlet If the TEST button does not trip or if the RESET button will not stay engaged discontinue use of the air conditioner and contact a qualified service technician Installation Instructions PARTS INCLUDED Window Appearance may vary IS sash seal Top mounting rail 2 ES Foam top _ gt S cos ZD L window gasket QA S Top mounting rail N DOM seal strip UP Left accordion ez Air accordion conditioner panel Type A 9 or 10 Type B 7 Security bracket 3 1 2 Screws 3 4 Screws E Installation Instructions 1 WINDOW REQUIREMENTS These instructions are for a standard double hung window You will need to modify them for other types of windows All supporting parts must be secured to firm wood masonry or metal The electrical outlet must be within reach of the power cord Follow the dimensions in the table and illustration for your model Models A B
48. ule service on line Schedule Service ge com Expert GE repair service is only one step away from your door Get on line and schedule your service at your convenience 24 hours any day of the year Or call 800 GE CARES 800 432 2737 during normal business hours Real Life Design Studio ge com GE supports the Universal Design concept products services and environments that can be used by people of all ages sizes and capabilities We recognize the need to design for a wide range of physical and mental abilities and impairments For details of GE s Universal Design applications including kitchen design ideas for people with disabilities check out our Website today For the hearing impaired please call 800 TDD GEAC 800 833 4322 Extended Warranties ge com Purchase a GE extended warranty and learn about special discounts that are available while your warranty gt is still in effect You can purchase it on line anytime or call 800 626 2224 during normal business hours GE Consumer Home Services will still be there after your warranty expires Parts and Accessories ge com Individuals qualified to service their own appliances can have parts or accessories sent directly to their homes VISA MasterCard and Discover cards are accepted Order on line today 24 hours every day or by phone at 800 626 2002 during normal business hours Instructions contained in this manual cover procedures to be performed by any user Other ser
49. umidor ge com SuJ Controles adicionales e informaci n importante 0193N1 No use en las condiciones externas debajo el punto de congelaci n Este acondicionador de aire no es dise ado para usar en temperaturas externas debajo el punto de congelaci n No use en las condiciones externas debajo el punto de congelaci n pepunBas ap sau Control de la ventilaci n en algunos modelos Ll 3 El control de ventilaci n est localizado al interior o RQ de las persianas en la esquina derecha inferior S Cuando esta ajustado en CLOSE CERRADO S 8 solamente el aire en el interior de la habitaci n ao circular y se acondicionar Cuando est ajustado p S 3 en OPEN ABIERTO un poco del aire interno es Para abrir la parrilla empuje la a expelido hacia afuera palanca hacia la derecha y para cerrarla hacia la izquierda Direcci n del aire de lado a lado La direcci n de lado a lado del aire es ajustada por las palancas de las persianas N gt 9 SS as O 296 Sy Ss o3 SD SU e Direcci n del aire Hacia arriba y hacia abajo en algunos modelos Una presi n sencilla con los dedos en las persianas horizontales ajustar la direcci n del aire hacia arriba o hacia abajo seuia go4d ap uoronjog Jopnunsuoa je ohody Instrucciones de seguridad LP Instrucciones de operaci n talaci n INS o S 4 S S S S 3 sy So
50. vicing generally should be referred to qualified service personnel Caution must be exercised since improper servicing may cause unsafe operation Contact Us ge com KoA If you are not satisfied with the service you receive from GE contact us on our Website with all the details including your phone number or write to General Manager Customer Relations GE Appliances Appliance Park Louisville KY 40225 Register Your Appliance ge com Register your new appliance on line at your convenience Timely product registration will allow for enhanced communication and prompt service under the terms of your warranty should the need arise You may also mail in the pre printed registration card included in the packing material 18 Printed in China Acondicionadores de Aire ge com Instrucciones de seguridad 2 3 Instrucciones de operaci n p o o Asus que ee ee ASQ05 Cuidado y limpieza ASVO5 Baterias c sente Aaa 8 ASMO6 Bobinas para exteriores 8 ASQ06 Filtro de aire o o ooo oo 8 ASV06 Parrilla y caja so ecco x 8 ASQOS Instrucciones de instalaci n 9 13 ASVOS Ideas para la identificaci n y reparaci n de problemas 14 15 Sonidos de operaci n normales 15 Apoyo al consumidor Apoyo al consumidor 18 Garantia ud e ee le ele rta 17 Producto etiquetado ENERGY STAR brerg ye Como socio de ENERGY STAR GE ha confirmado que este producto cumple las directrices d
51. w direction 2 Insert new batteries making sure that the and of battery are installed correctly 3 Reattach the cover by sliding it back into position Grille and Case Turn the air conditioner off and remove the plug from the wall outlet before cleaning Outdoor Coils The coils on the outdoor side of the air conditioner should be checked regularly If they are clogged with dirt or soot they may be professionally cleaned Air Filter The air filter behind the front grille should be checked and cleaned at least every 30 days or more often if necessary Clean the filter with warm soapy water Rinse and let the filter dry before replacing it A CA U TI ON DO NOT operate the air conditioner without a filter because dirt and lint will clog it and reduce performance NOTES Use 2 AAA 1 5 volt batteries Do not use rechargeable batteries Remove the batteries from the remote control if the system is not going to be used for a long time To clean use water and a mild detergent Do not use bleach or abrasives To remove Grab the tabs on the filter and pull it up and out 1 Pull open the inlet grille at the bottom and lift off to remove 2 Pull the top of the filter down and out to remove Installation Instructions BEFORE YOU BEGIN Read these instructions completely and carefully ai IMPORTANT Save these instructions for local inspector s use IMPO

Download Pdf Manuals