1. Start Configuration Wizard This wizard will guide the user through the following configuration tasks Configuration options selected here can be modified individually later 1 Create RAID Group A new RAID Group is created or an existing RAID Groups is selected in order to create a new Logical Volume 2 Create Volume Create Volume in Created Selected RAID Group 3 Configure Host Access Configure Host Access connection 4 Set Affinity Group Create or Modify Affinity Group 5 Define LUN Map Specify LUN Map for access by Host s connected to each Port Click Start to start the Configuration Wizard Create RAID Group Create Volume Define Host 7 2 2 Configuration Wizard in the User Guide See g Default RAID groups volumes and affinity groups are preset in the factory Refer to Web Configure Affinity Group Define LUN Mapping GUI User Guide if the preset values are to be changed El Assigning Hot Spares Register hot spares for use in case the regular disks fail The Assign Hot Spare screen appears by clicking Assign Hot Spare under the RAID Group Management menu on the Volume Settings tab See 7 2 3 Hot Spare Registration in the User Guide Check the factory settings and register a hot spare as required STEP Monitoring Setup A Perform the ETERNUS DX60 DX80 monitoring setup if required Notification of ETERNUS DX60 DX80 problems as they occur is possible if
2. ETERNUS DX60 DX80 is 2U Screw location of the rack rail bracket Tighten the screws in the same locations on both the front and rear sides of the rack pillars Left Right SES ate E PI 3rd position la _ 3rd position We corns a ETERNUS DX60 DX80 S A 1st position dl eS eR nN ea ae 1st position M5 screws M5 screws Base line of the ETERNUS DX60 DX80 Rack rail bracket Various cables need to be connected to the rear of the ETERNUS DX60 DX80 To help with cable management and prevent incorrect connection attach labels to the cables and make a note of connection origins and destinations IMPORTANT The cables should never be bent twisted or pulled Ei LAN Cables CUR Controller may Enclosure Th on the left side and MNT port is on the right side The MNT port must always be connected The RMT port only needs to be connected when the remote support connection is to be independent of the customer network S amp 6 2 LAN Cable Connection for Operation Management in the User ee Guide EJ MiniSAS Cables for Host Interface Rear view CHR Controller n omer Enclosure For each CM the port numbers are left to right 0 and 1 Connect a miniSAS cable to each of these ports 6 5 MiniSAS Cable Connection For SAS in the User Guide See eee 3 Mount the ETERNUS DX60 DX80 in the rack IMPORTANT Make sure to install or remove the enclo
3. in the User ee Guide E Power Cords Use release ties to hold the power cords in place Rear vie ate Drive Enclosure Controller Enclosure 6 7 Power Cord Connection in the User Guide See Connect the PC to the ETERNUS DX60 DX80 with a LAN cable for operation management and turn on the ETERNUS DX60 DX80 7 1 Setup Preparation in the User Guide 7 2 Basic Setup in the User Guide IMPORTANT The first time the power is turned on volume formatting may start according to the factory default settings This does not affect the setup operation which may be started immediately Power switch Controller Enclosure Basic Setup Basic ETERNUS DX60 DX80 setup is performed by accessing the Initial Setup and Configuration Wizard functions with a Web browser 1 Start the Web browser on the PC and enter either of the following URLs in the address bar of the Web browser http 192 168 1 1 https 192 168 1 1 2 Enter the following user name and password and click the Logon button to logon to the ETERNUS DX60 DX80 User name root Password root Default 3 After logging on the Storage System Status screen appears When ETERNUS SF Express is used perform the following setup and then refer to the ETERNUS SF Express User s Guide to install the ETERNUS DX Disk storage system EF Initial Setup Set Date and Time Set Storage System Name Cha
4. the event notification method and level have been set For e mail notification of ETERNUS DX60 DX80 problems a destination e mail address must be set If ServerView is used to monitor the server the ETERNUS DX60 DX80 must be set to send an SNMP Trap to the server If remote support is required the ETERNUS DX60 DX80 must be set to notify the remote support center of failures Remote support allows prompt detection and resolution of trouble 7 4 Monitoring Setup in the User Guide See ume STEP Server Connection Various tasks need to be performed before the ETERNUS DX60 DX80 can be connected to the server These include the installation of the appropriate drivers Check which server OS and or SAS card are to be connected to before starting this step For details on the setting refer to ETERNUS DX Disk storage systems Server Connection Guide SAS Download from the specified web site in the Documentation CD See 7 5 Server Connection Setup in the User Guide ETERNUS DX Disk storage systems Server Connection Guide SAS for Windows for Linux for Solaris Operating System ETERNUS DX Disk Storage System Settings for ETERNUS DX60 DX80 for VMware ESX All necessary settings are complete and the ETERNUS DX60 DX80 is now ready for normal operation Operation and Maintenance Status check The status of the ETERNUS DX60 DX80 should be regularly monitored by checking the
5. LEDs and using the Web browser Data backup Important data should be regularly backed up to a tape drive or similar device as a precaution against system failures Maintenance support period The maintenance support period for the ETERNUS DX60 DX80 is 5 years from the date of purchase ETERNUS DX60 DX80 Disk storage system Setup Guide SAS model P3AM 3102 04EN Date of issuance July 2010 Issuance responsibility FUJITSU LIMITED Printed in Japan The contents of this manual may be updated without notice While the contents of this manual are the product of all due care and diligence no responsibility can be accepted for operational problems arising from any errors or missing information or other use of the information contained in this manual Fujitsu assumes no liability for damages to third party copyrights or other rights arising from the use of any information in this manual Contents of this manual are not to be reproduced without permission from Fujitsu Manuals with missing or wrongly collated pages will be replaced free of This manual uses recycled paper charge
6. P3AM 3102 04EN Workflow 1 Preparation 5 Basic Setup 2 Installation 6 Monitoring Setup 3 Cable Connection 7 Server Connection Seed a iita 4 Startup 8 Operation and Maintenance Z CAUTION Do Read and understand the Safety Precautions before use The company names product names and service names mentioned in this document are registered trademarks or trademarks of their respective companies Copyright 2010 FUJITSU LIMITED The latest version of this document and the latest information about the ETERNUS DX60 DX80 is released in the following web site Access the following address if needed http www fujitsu com global services computing storage eternus products diskstorage dx entry STEP Preparation fl Package Contents Check Refer to the Package Contents and check that there are no missing items L ETERNUS DX60 DX80 L Misc documents Prepare the following manuals Documentation CD Safety Precautions Package Contents Other related manuals for example for a server or networking equipment When ETERNUS SF Express is used prepare the following software and User s Guide ETERNUS SF Express Media Pack ETERNUS SF Express User s Guide See Package Contents EJ Installation and Connection Preparation EI Setup Preparation Installation space Completing and attaching the Network Settings label Check that the installation area meets the space requirements Complete the follow
7. ing information in the Network Settings of the rack in which the ETERNUS DX60 DX80 is to be installed label and attach it on the ETERNUS DX60 DX80 Installation requirements IP address and subnet mask for the ETERNUS DX60 Check that the installation area satisfies all the requirements DX80 described in the Instructions for installation section of the IP address for maintenance work Safety Precautions Settings for the PC Setup Network Environment IP address 192 168 1 2 Subnet mask 255 255 255 0 Power outlets CCC Set the Web browser Check that a sufficient number of suitable wall outlets are Environmental conditions Temperature 5 40 C Humidity 20 80 RH Proxy server and Cache Disable available Java Script style sheets and cookies Enable 5 1 Installation Preparation in the User Guide 7 4 Setup Preparation in the User Guide see 6 1 Connection Preparation in the User Guide See i j Safety Precautions Proceed to next step D Installation The rack rail bracket needs to be attached to the rack and the ETERNUS DX60 DX80 mounted 1 Adjust the rack rail bracket size to fit the rack L is stamped on the inner side of the left rack rail and adjust the rack rails to the depth of the rack lt Left Loosen the screws R is stamped on the inner side of the right rack rail 2 Attach the rack rails brackets to the rack The size of the
8. nge Password Setup Network Environment AE Initial Setup Set the necessary environment for operating the ETERNUS DX60 DX80 with its initial setup The Initial Setup screen appears by clicking the Initial Setup menu on the Easy Setup tab This screen is used to set the following items Set Date and Time Set Storage System Name Change Password Set SAS Port Parameters Setup Network Environment agement interface ports are setup Select Network Port MNT CRMT Interface Speed and Duplex Master CM IP Address Slave CM IP Address Subnet Mask Default Gateway Primary DNS Secondary DNS http https telnet SSH Enable Disable Maintenance Enable Disable Maintenance Secure ICMP Allowed IP List No IP Address After completing these settings with the Finish step close the web browser to end the setup session then detach the direct connection LAN cable for operation management from the PC and connect it to the normal network Then try logging on again via the normal network using the IP address that has just been set 7 2 1 Initial Setup in the User Guide See E Configuration Wizard Perform the necessary settings to operate the ETERNUS DX60 DX80 using the Configuration Wizard The Configuration Wizard screen appears by clicking the Configuration Wizard button on the Easy Setup tab Series of procedures required to provision storage
9. sure to or from the rack by two or more people Multiple Drive Enclosures must be connected to the controller enclosure following the order of the DE_No label numbers attached to each Drive Enclosure The position of the labels are in the positions shown below Between the EXP 0 and EXP 1 expanders at the rear of the drive enclosure At the right side of the front of the drive enclosure CANN DE_No label 4 Fasten the ETERNUS DX60 DX80 to the rack See 5 2 Rack Installation in the User Guide Cable Connection E MiniSAS Cables for Drive Enclosures When Drive Enclosures are installed miniSAS cables are used to connect between the SAS ports of the enclosures Connect the Controller Enclosure to Drive Enclosure 1 Drive Enclosure 1 to Drive Enclosure 2 Drive Enclosure 2 to Drive Enclosure 3 etc The number of Drive Enclosure can be checked with the DE_ No label Example for connection of miniSAS cable when two Drive Enclosures are installed Rear view Underside of the SAS OUT side plug I N lO Underside of the SAS IN side plug ee Oe Lo j 6 Why UT port is on the left side and SAS IN port is on the right side Insert the connector with a mark on its underside in the SAS OUT port Insert the connector with a mark on its underside in the SAS IN port S 6 6 MiniSAS Cable Connection For Drive Enclosures