Fujitsu C150-E049-02EN Photo Scanner User Manual
Contents
1. Bit 7 6 5 4 3 2 1 0 Byte 0 Reserved Page Code 3Eh 1 Page Length 06h 2 Job Separation Sheet Parameter 3 _ Reserved 7 Job Separation Sheet Parameter field specifies Job Separation Sheet information in each bit Table 3 74 Job Separation Sheet Parameter Value Description Oxxxxxxxb Disable Job Separation Sheet detection default 1xxxxxxxb Enable Job Separation Sheet detection If Bit7 1 then when Job Separation Sheet is detected CHECK CONDITION will be returned M 3099GX GH OEM M anual 3 91 INTERFACE ENDORSER Command ENDORSER option is required The ENDORSER command Table 3 75 specifies to control Mechanical Endorser If ENDORSER option is not attached CHECK CONDITION status will be returned and SENSE KEY is set to ILLEGAL REQUEST Table 3 75 ENDORSER Command Bit 7 6 5 4 3 2 1 0 Byte 0 Operation Code C1h 1 Logical Unit Number Reserved 2 Reserved 3 Reserved 4 Reserved 5 Reserved 6 Reserved 7 MSB Transfer Length Ps fo LSB 9 Control The transfer length specifies the length in bytes of the data that shall be sent during the DATA OUT phase A transfer length of zero indicates that no Endorser Descriptors shall be transferred This condition shall not considered as an error The length of an Endorser Descriptor is 4 bytes therefore Transfer Length must be multiple
2. Load Object a document j Y Start scanning operation This command is required to PG SCAN ID 00h 80h specify duplex mode scanning The window identifiers should be sent 00h 80h order for future extention Transfer front side Data Type Qualifier 0000h image data READ ID 00h from scanner READ command would be issued one or more The details of READ command sequence is 4 9 5 Transfer back side Data Type Qualifier 0080h image data READ ID 80h from scanner READ command would be issued one or more The details of READ command sequence is 4 9 5 Feed out document from ADF This command is omissible because end of scanning automatically feeds J out document RELEASE UNIT Release exclusive use of the scanner 1 This loop is used to scan a batch of document 2 This loop is used to scan a batch of identical format window parameter document at maximum speed 3 116 M 3099GX GH OEM M anual Endorser Control The Endorser Control requires Endorser option This endorser function is assumed that a batch of documents are scanned and each document is printed serial number Therefore ENDORSER command just only specifies start and stop of endorsement and does not interfere with scanning command sequence Endorser Data is sent to scanner a head of issuing ENDORSER command The endorser function is invoked by READ command internally INTERFACE Fo
3. banus dove onn aided 8 7 ENDORSER Re A 1 Al Spp dicen od tero d dea I aad CU E ERE A 1 A2 Panel Gpetatiogis seio ndun A 2 A2 1 How to set the endorser ON or OFF 2 A2 2 How to set the initial number iiu ace re riens A 2 A2 3 How to set the print number reset condition A 3 A2 4 How to reset the print number manually A 3 A2 5 How to reset the print head life counter 4 A2 6 How to test the printing the operator parel Operation a aver 4 5 A3 1 Replacing the print head sexi cucsiujeconsceveniedbcdnsvientianesneesats A 5 A3 2 Print head position adjustment cicsurorssivecssatserprovsnvsnoccees A 6 SETUP MODE B 1 Bly Activatiag the setup mode B 1 B2 Operational transition in the setup mode B 1 B3 Contents of the set p imode B 2 B3 1 Setting double feed detection B 3 B3 2 Setting IPC 2 pre set mode B 4 D3 3 Reset of abrasion B 6 aa E clo cident B 7 Dio Settle PIC B 7 M 3099GX GH OEM M anual vii 10 Pasting LCD CONTAS B 8 B37 Seting Pick Spec ui B 8 B3 8 Setting initial value oFatidof SEE caso B 9 B3 9 Setting
4. 3 Disconnect the two relay connectors on the roller Lever green ASY 4 Push the two levers green towards each other to disengage with the upper locking holes and lower down the two levers until they engage with the two levers locking holes Roller ASY M 3099GX GH OEM M anual 4 21 Guide plate Bracket Guide plate 5 Lift the document sensor unit and keep it at the upper position with one hand and pull the roller ASY out with the other hand 6 Move the guide on the hopper table completely to the end 7 Hold both ends of the guide plate and press them down to remove the guide Press the bracket in the direction A and detatch the bracket and pad Note When assembling the pad align the holes the pad with the projection of the guide plate 4 22 M 3099GX GH M anual Device and Operator Actions for Temporary Errors ERROR PROCESSING AND RECOVERY This chapter provides how to handles temporary errors and equipment errors and what the operator should do to recover the scanner Table 5 1 lists the scanner and operator actions for temporary errors Table 5 1 Device and operator actions for temporary errors LCD display 1 Scanner actions 2 Action to recover 3 PAPER JAM The normally read document is ejected to the stacker and the mechanism system is stopped to suspend the read operation Te
5. 3 89 2 Lamp Tel reri Robe bcd 3 90 3 73 job separation Sheet 9 91 3 74 Job Separation Sheet Parameter 3 91 3 75 ENDORSER Command 3 92 3 70 Endorser Descriptors 3 93 3 77 Endorser ada oeste Rn oki Raast RUMP M RE 3 94 3 78 EO inches ineat erint o EU ees 3 95 379 DIRS cT 3 96 3 80 Status deret ettet tte tie de Er ERE 3 97 381 Status 3 97 3 82 Message Format sisme ni N E Eee 3 99 3 83 Message 3 100 3 84 Extended Message Format oiseau eed 3 101 3 85 Extended Message COS uas ieiunio io acie 3 101 3 86 IDENTIFY sen 3 104 3 87 SYNCHRONOUS DATA TRANSFER REQUEST 3 107 4 Button functions ieres arenie id teta E D 4 4 4 4 BD A 4 8 5 1 Device and operator actions for temporary errors 5 1 5 2 Device and operator actions for equipment errors 5 4 NES ud ER P MN 7 1 752 ANCCESSOMES teen tates 7 2 8 1 Cleaning locations and frequencies eorr rrt onte 8 1 A Bndorser specifications 1 xii M 3099GX GH OEM M anual Chapter 1 Overview Chapter 2 Specifications Chapter 3 Interface Chapter 4 Basic Operation Chapter 5 Error Processing and Recovery Chap
6. 5 4 CHAPTER 6 DOCUMENT SPECIFICATION 6 1 D cument T 6 1 D ment Quality INNEREN eik 6 2 Document 6 2 Ream TET 6 2 Precautions M 6 2 Documbat 6 4 Areas that must not be perforated 6 4 Print prohibit areas on the front and back surfaces 6 5 Grounding Color Ateas a queritur brit petens tstesvt nitent ase erditieeig 6 6 Dropout Cl soi inner n D DIM RR e UN anA DUE 6 7 Print density measurement eee 6 7 6 7 Job S paration Sheet ME 6 8 Shape Met PHP PHP A AEREA pen SE Tee re 6 8 DOCUMENT t Pe sssini ere 6 8 vi M 3099GX GH OEM M anual 7 CHAPTER 8 APPENDIX A APPENDIX B CONSUMABLES AND ACCESSORIES 7 1 Consumables e 7 1 Praec m M n 7 2 CLEANING m 8 1 Cleaning Locations and Frequencies esurire 8 1 cnn Mi P 8 2 DUERME ID 8 2 Cleaning the front side eost enin 8 2 Cleaning Xe Rollers oer irt 8 5 Cleaning the transport paths 8 6 Cleaning the glass SURG qe cose apte ds puce 8 7 Cleaning ilie
7. Remove the document OVER the ADF exceed the to the specified number LOAD specified number of pages of sheets M 3099GX GH OEM M anual 5 3 ERROR PROCESSING AND RECOVERY Device and Operator Actions for Equipment Errors Table 5 1 Device and operator actions for temporary errors continued LCD display Scanner actions Action to recover PRINT Print head is not set Press STOP to reset HEAD Temporary Error is returned the error and set the NOT SET to the host computer and an print head again error message is displayed on the LCD display PRINT Print head is not set correctly Press STOP to reset HEAD or does not work well the error and set the ALARM Temporary Error is print head again returned to the host compu If the error message is ter and an error message is displayed on the LCD displayed on the LCD display again change display the print head Table 5 2 lists the scanner and operator actions for equipment errors Table 5 2 Device and operator actions for equipment errors The mechanism system is stopped LCD display Scanner actions Action to recover HOPPER The Check lamp lights and Check if the ALARM error message is displayed on lamp or heater is the LCD display attached The mechanism system is correctly stopped Replace lamp TRANS The Check lamp lights and an the PORT err
8. 4 1 Operator panel 4 3 Document size 6 1 Areas that must not be pertoratetlius uenerit 6 4 Print prohibit areas on the front and back surfaces 6 5 Grounding 6 6 Bue tr band 6 7 6 8 ANCA DEEP 1 30996 OEM M anual Tables LUE 1 1 12 Typesot MOSOUDGN 1 2 2 1 General scatiner specifications 2 1 2 2 Electrical specifications ener n ERE 2 2 2 3 Environmental specifications 2 2 2 4 Phiysical 2 5 2 5 Option SPECULAAS 2 6 3 1 SCSI physical accentu peser teint ted 3 4 3 2 Single Ended Contact Assignment Cable 3 6 20 56 9I DusSio 3 8 JA SOUC TR 3 10 3 5 SCSI Bus Timing al m c a 3 6 Information Transfer eerta cin Eno laxe 3 20 37 Operation Code 3 29 3 8 RESERVE UNIT Command 3 30 3 9 RELEASE UNIT een teer pa eaa ccr 3 31 3 10 TEST UNIT READY Command 2 ete ee tis 3 32 3 11 INQUIRY Gommand 2 ete eet piene 3 33 3 12 Standard INQUIRY Data Format seen 3 35 3 13 Standard Page Format 3 38 3 14 Standard Resolution unit Pixel Inch 3 39 DD M ian 3 40 3 16 Standard VPD Page Extended Form
9. 80h Enable Automatic Separation 81h to FFh Reserved Mirroring 00h 80h with IPC2 This field specifies flip left and right of image Table 3 47 Mirroring Value Description 00h Default Disable Mirror Olh to 7Fh Reserved 80h Enable Mirror 81h to FFh Reserved M 3099GX GH OEM M anual 3 67 INTERFACE SDTC parameter OOh reserved 00h 01h to FFh with IPC2 The SDTC parameter field specifies SDTC Simplified Dynamic Threshold Circuit parameter This parameter specifies variance rate of threshold Table 3 48 SDTC parameter Value Description 00h Default 016 to 20h to 3Fh 40h to 5Fh 60h to 7Fh 80h to 9Fh to to DFh to FFh Small Normal V Big DTC Mode 0000h without IPC2 XXXXh with IPC2 The DTC Mode field specifies Dynamic Threshold Circuit mode parameters 3 68 M 3099GX GH OEM M anual Table 3 49 DTC Mode Byte 47 value bit Description 1xxxxxxxb Ball Point Pen Mode Enable Oxxxxxxxb Disable x00xxxxxb Smoothing Mode OCR x01xxxxxb Scanner x10xxxxxb Undefined x11xxxxxb Undefined xxx00xxxb Gradation Ordinal Image xxx01xxxb High Contrast xxx1xxxxb Reserved xxxxx000b Threshold Curve Light for OCR xxxxx001b xxxxx010b
10. eese eerte 3 14 Reset Hold Time en 3 14 Selection Abort Time esee 3 14 Selection Timeout Delays ies tti m t tn vetas mH 3 14 Transfer Period 3 15 SCSI Bus Phases iiti ie eret ee eR EE DE EE EE CHEER ELE E EC URS 3 15 BUS FREE Phase See ANSI SCSI 2 6 1 1 for details 3 15 ARBITRATION Phase sinesine enas 3 16 SELECTION Phase i Diet iem eere eei 3 17 RESELEGTION Phase 4 iei ett ett t tt tto eis 3 18 RESEEEG TION eiecit itr er eee tun 3 18 Information Transfer Phases eee 3 19 Asynchronous Information Transfer 3 20 Synchronous Data Transfer 3 21 COMMAND Phase eene 3 22 Data Phe 3 22 DATAIN 3 25 DATA OUT Phase eese 3 23 STATUS PHASE 3 23 Message 3 23 MESSAGE IN 3 25 MESSAGE OUT Phase See ANSI SCSI 2 6 1 9 2 for detalles sce uinci iiA i LL 3 24 SCSI Bus Conditions cccccecccsssccessseescecesssecssecesseceesscesseecsseees 3 24 Attention Condition 3 24 Reset Condition eee eee 3 25 SCRI Bus hases Sequences sissi nienie iniii eis 3 26 Commands See ANSI SCSI 2 7 3 27 RESERVE UNIT Command eee 3 30 Superseding Besetvatids 5 31 RELEASE UNIT 3 31 TEST UNIT
11. Cleaning cloth dry cloth lint free Cleaner F2 e Isopropyl alcohol Cleaner F1 Cleaning sheet Q Tips NOTICE Cleaner F2 should be used for steel rollers Procedure This section provides instructions on how to clean each section of the scanner WARNING Wait at least 3 minutes after turning off the power before cleaning Cleaning the front side lamp Operator l Turn offthe power switch pls 2 Open the upper transport unit See page 4 2 Lever Power switch Lamp socket covers 3 Remove the two lamp socket covers U shaped spring clips by pulling them out of their positions 8 2 M 3099GX GH OEM M anual Upper transport unit 4 Rotate the lamp so that the two terminals on each and align with the exit slot on the lamp socket Maintain the alignment and remove the lamp from the lamp sockets CAUTION Be careful not to pull the wire of the heater hard 5 Clean the lamp with a dry cloth CAUTION Be careful not to peel the tape on the heater If any visible damage on the heater is observed please contact manufacturer s authorized service center for proper repair service M 3099GX GH OEM M anual 8 3 Note Make sure that the following lengths are the same dicus Q b b2 Heater Window Cross sectional view of lamp and heater 6 re install lamp heater reverse procedures in item 4 above Socket Front Note When re installing th
12. Product Identification M3099GH M3099GHdm default Duplex 2 equivalent M3099GHdem li with ENDORSER option M3099GHdim with IPC2 option M3099GHdeim i with ENDORSER IPC2 options Product Identification M3099GX M3099Gdm default Duplex CMP2 equivalent M3099Gdem i with ENDORSER option M3099Gdim with IPC2 option M3099Gdeim with ENDORSER IPC2 options Product Identification M3096G M3096Gm i default M3096Gim with IPC2 option Product Revision Level 01 Black and White Binary Vital Product Data JBMS apanese Business Machines Standard is defining standard Vital Product Data See JBMS 40 1990 Fujitsu Scanners also support this data by adding Fujitsu original extention JBMS 40 1990 uses 30 Bytes as standard VPD to describe specification and functions This data is obtained by setting EVPD bit to 1 and Page Code to FOh in INQUIRY command If Product Identification has changed to M3096G or M3099G in Off line SETUP mode following data are returned The d which indicates Duplex and which indicates ENDORSER are not returned See Chapter 4 Operator panel M 3099GX GH M anual 3 37 Table 3 13 Standard VPD Page Format Bit 7 6 5 4 3 2 1 0 Byte 0 Peripheral Device Type 1 Page Number FOh 2 J Version 3 Reserved 4 Page Length m 5 5 MSB Basic X
13. 3 112 M 3099GX GH OEM M anual TEST UNIT READY 1 GOOD exit LOGICAL UNIT READY CHECK CONDITION REQUEST SENSE 2 TEST UNIT READY 3 GOOD exit LOGICAL UNIT READY CHECK CONDITION REQUEST SENSE 4 TEST UNIT READY 5 GOOD exit LOGICAL UNIT READY CHECK CONDITION REQUEST SENSE 6 NOT READY exit LOGICAL UNIT READY Figure 3 6 Verify State Test TEST UNIT READY 1 This TEST UNIT READY command is used to determine if any outstanding CHECK CONDITION or UNIT ATTENTION condition exists If not the device is indicated to be ready REQUEST SENSE 2 This REQUEST SENSE command is used to clear the outstanding CHECK CONDITION Most SCSI 2 logical units return UNIT ATTENTION sense key in this sense information OTHER CHECK exit LOGICAL UNIT FAILED M 3099GX GH OEM M anual 3 113 INTERFACE TEST UNIT READY 3 This TEST UNIT READY command is used to see if the UNIT ATTENTION condition or other error was successfully cleared In some special cases another error may have been nested with the UNIT ATTENTION and this TEST UNIT READY command may also return CHECK CONDITION status REQUEST SENSE 4 This REQUEST SENSE command is used to determine which error or exception was associated with the CHECK CONDITION status returned by the TEST UNIT READY 3 command In addition this REQUEST SENSE command is used to clear the outstanding CHECK CONDITION This may
14. Front side Reading surface wu Bottom of document 50 ET Ej gt ET ET Center of document Figure 6 3 Print prohibit areas on the front and back surfaces M 3099GX GH OEM M anual 6 5 Grounding Color Area As Figure 6 4 shows the top 3 mm part of the read area on each surface should be left blank grounding color by specifying a drop out color If the drop out color cannot be specified select Photo for the document type line drawing or photograph For details of the drop out color see next Section Grounding color white or drop out color area M ain scanning direction Reading reference Subscanning direction Figure 6 4 Grounding color area 6 6 M 3099GX GH OEM M anual Drop out Color drop out color is color visible by a human eye but not visible to the scanner To check the grounding color of document for a drop out color use the method and follow the standards given below Print density measurement The spectrum chart shows in Figure 6 5 is used to measure print density The measurement must be made in one of the following ways A light source using fluorescent G54 Macbeth PCS meter PCM II is used which requires a filter DOCUMENT 100 SPECIFICATION Relative response 400 450 500 550 600 650 700 750 nm Figure 6 5 Spectrum band Drop out color standards In the spectrum of fluorescent lamp G54 the PCS value must satisfy the follo
15. M 3099GX GH OEM M anual If the I O signal is false transfer to the target the target shall request information by asserting the REQ signal The initiator shall drive the DB 7 0 P signals to their desired values delay at least one deskew delay plus a cable skew delay and assert the ACK signal The initiator shall continue to drive the DB 7 0 P signals until the signal is false When the ACK becomes true at the initiator the initiator may change or release the DB 7 0 P signals and shall negate the ACK INTERFACE signal After the ACK signal is false the target may continue the transfer by asserting the REQ signal as described above Synchronous Data Transfer Synchronous data transfer is optional and is only used data phases It shall be used in a data phase if a synchronous data transfer agreement has been established see S YCHRONOUS DATA TRANSFER REQUEST Message The agreement specifies the REQ ACK offset and the minimum transfer period The REQ ACK offset specifies the maximum number of REQ pulses that can be sent by the target in advance of the number of ACK pulses received from initiator establishing a pacing mechanism If the number of REQ pulses exceeds the number of ACK pulses by the REQ ACK offset the target shall not assert the REQ signal until after the leading edge of the next ACK pulse is received A requirement for successful completion of the data phase is that the number of ACK and pulses be equa
16. Table 3 17 Physical Function Byte Description 32 1XXXXXXXb Automatic Document Feeder Flatbed XX1XXXXXb Tranceparency XXX1XXXXb Duplex XXXX1XXXb Endorser XXXXX1XXb Barcode XXXXXX1Xb Operator Panel XXXXXXX1b Reserved 33 0000nnnnb Bits of ADC Buffering Capability 0080 0000h 8M Bytes Buffering Capability field indicates that interface buffering capability in bytes Implemented Standard Command 0000 0000 0000 0000 1110 1101 1011 1111b 0000EDBFh Implemented Standard Command field of each bit indicates supported SCSI command as Table 3 18 M 3099GX GH OEM M anual Table 3 18 Implemented Standard Command Command Code 0 TEST UNIT READY 00h M 1 REQUEST SENSE 03h M 2 INQUIRY 12h M 3 MODE SELECT 6 15h O 4 RESERVE UNIT 16h M 5 RELEASE UNIT 17h M 6 18h O 7 SENSE 6 1Ah O 8 SCAN 1Bh O 9 RECEIVE DIAGNOSTIC RESULTS 1Ch O 10 SEND DIAGNOSTIC 1Dh M 11 SET WINDOW 24h M 12 GET WINDOW 25h 13 READ 28h M 14 SEND 2Ah O 15 OBJECT POSITION 31h O 16 GET DATA BUFFER STATUS 34h O 17 COMPARE 39h O 18 COPY AND VERIFY 3Ah O 19 WRITE BUFFER 3Bh O 20 BUFFER 3Ch O 21 CHANGE DEFINITION 40h O 22 LOG SELECT 4Ch O 23 LOG SENSE 4Dh O 24 MODE SELECT 10 55h O 25 MODE SENSE 10 5Ah O 26 Reserved 27 Reserved 28 Reser
17. responsible to change the print head as follows Endorser cover DOpen and remove the endorser cover at the rear top corner of the scanner Power of the scanner will turn off if the power is on at cover open Turn the print head lock lever up then ENDORSER P P i replace the print head Print head Print head lock lever Attach the new print head in the endorser and turn the print head lock lever back Z Close the endorser cover back M 3099GX GH OEM M anual A 5 5 Reset the print head counter by the procedure stated in section A2 5 See NOTICE You can test the printing by the procedure in section A2 6 NOTICE The reset of the print head life counter is important to correctly detect the life of the new print head A32 Printhead position adjustment You can adjust the print position in mainscanning direction manually The position you can set is limited as stated in section 1 Endors t tovr 1 Open and remove the endorser cover at the rear top corner of the scanner Power t of the scanner will turn off if the power is on at the cover open 2 Pinch the tab near the print head and slide it to the position you want to print The print position is indicated by the indicater behind the tab and the label br attached on the rear cover 3 Close the endorser cover You can test the printing by the procedure in section A2 6 A 6 M 3099GX GH OEM M anual APPENDIX SETUP M
18. 150 049 02 M3099GX GH IMAGE SCANNER OEM MANUAL co FUJITSU M3099GX GH IMAGE SCANNER OEM MANUAL co FUJITSU REVISION RECORD Edition Date published Revised contents 01 Feburary 1996 First edition 02 April 1996 Setup mode etc revised Specification No C150 E049 02EN The contents of this manual may be revised without prior notice All Rights Reserved Copyright 1996 FUJITSU LIMITED Printed in Japan No part of this manual may be reproduced in any form without permission Address your comments and inquiries on this manual to FUJITSU COMPUTER PRODUCTS OF AMERICA INC 2904 Orchard Parkway San Jose California 95134 2022 U S A TEL 1 408 432 6333 FAX 1 408 432 3908 FUJITSU AUSTRALIA LIMITED 475 Victoria Avenue Chatswood N S W 2067 AUSTRALIA TEL 61 2 410 4555 FAX 61 2 411 8603 FUJITSU CANADA INC 2800 Matheson Blvd East Mississauga Ontario 4X5 CANADA TEL 1 905 602 5454 FAX 1 905 602 5457 FUJITSU DEUTSCHLAND GmbH Frankfurter Ring 211 8000 Munchen 40 F R GERMANY TEL 49 89 32378 0 FAX 49 89 32378 100 FUJITSU ESPANA S A Edificio torre Europa Paseo de la Castellana 95 Madrid 28046 SPAIN TEL 34 1 581 8400 FAX 34 1 581 8125 FUJITSU EUROPE LTD 2 Longwalk Road Stockley Park Uxbridge Middlesex UB11 1AB U K TEL 44 81 573 4444 FAX 44 81 573 2643 TLX 263871 FUJITSU FRANCE S A Batiment
19. MM The extended message length specifies the length in bytes of the extended message code plus the extended message arguments to follow Therefore the total length of the message is equal to the extended message length plus two A value of zero for extended message length indicates 256 bytes follow The extended message codes are listed in Table 3 85 The extended message arguments are specified within the extended message descriptions Table 3 85 Extended Message Codes Code s Description 02h Reserved See Note 00h MODIFY DATA POINTER 01h SYNCHRONOUS DATA TRANSFER REQUEST 03h WIDE DATA TRANSFER REQUEST 04h 7Fh_ Reserved 80h FFh Vendor Specific Note Extended message code 02h was used for the EXTENDED IDENTIFY message in SCSI 1 M 3099GX GH OEM M anual 3 101 INTERFACE The supported extended message by this scanner is SYNCHRONOUS DATA TRANSFER only The first message sent by the initiator after the SELECTION phase shall be an IDENTIFY ABORT or BUS DEVICE RESET message If a target receives any other message it shall go to BUS FREE phase see unexpected disconnect ANSI SCSI 2 6 1 1 If the first message is an IDENTIFY message then it may be immediately followed by other messages such as the first of a pair of SYNCHRONOUS DATA TRANSFER REQUEST messages The IDENTIFY message establishes a logical connection between the initiator and the specified logical unit or targ
20. in the manual mode issuing the start command Load documents on the hopper and start reading them 5 2 M 3099GX GH OEM M anual Table 5 1 Device and operator actions for temporary errors continued LCD display Scanner actions Action to recover COVER The mechanism system 15 Close the upper OPEN stopped immediately and transport unit or the an error message is endorser cover displayed Or turn the thumb on the LCD display screw to lock the If the scanner is not back side lamp unit working Temporary Error is returned when a SENSE START or READ command is received The hopper table is lowered to the bottom MISS When an error is detected Open the upper PICK magnetic clutch pick clutch transport unit and is turned off and the normally remove the document scan document is ejected to on the transport path the stacker Then close the unit Then the mechanism system Return the jammed is stopped document on the Temporary Error is returned hopper and read it to the host computer and an again error message is displayed on the LCD display The hopper table is lowered to the bottom ROLLER The ADF roller ASY is not Open the upper UNIT mounted correctly transport unit and NOT SET correct the roller unit setting then close the upper transport unit See chapter 4 Roller ASY Replacement HOPPER The documents loaded
21. lt gt gt TEM ENDORSER INITIAL screen Screen 2 ENDORSER INITIAL Then press Mode 2 If ON is displayed the endorser is already on Screen 2 Screen 3 If OFF is displayed press Mode 1 ENDORSER VALUE 3 Payee p c until OFF blinks Then press Mode 2 ON 00001 to turn the endorser ON Screen 3 Screen 3 If you want to set the status in EEPROM go to 5 Then if you want to close the job go to 6 and NOTICE Set the endorser ON only when you use endorser or the characters may be printed on every scanned document A2 2 How to setthe initial number Initial number is the number which the scanner starts printing or returns after the reset of print number ENDORSER VALUE 4 Screen 3 press the Mode 1 until the digit you want to changes blinks Then press Mode 2 until the digit changes as Screen 4 you want Screen 4 In this case the initial number is five A 2 M 3099GX GH OEM M anual EEPROM WARITE Mode 2 Write Screen 5 EEPROM Writing Screen 6 S To set the status in EEPROM press Mode 1 until blinks Then press Mode 2 to change the LCD display into Screen 5 If you want to set press Mode 2 And the LCD displays Screen 6 about three seconds If you want to return to the ENDORSER INITIAL screen Screen 2 press Mode 1 and Mode 2 at a time press STOP A2 3 Ho
22. manage this condition as an unsuccessful I O process termination The target terminates the I O process by clearing all pending data and status information for the affected nexus The target may optionally prepare sense data that may be retrieved by a REQUEST SENSE command ARBITRATION Phase The ARBITRATION phase allows one SCSI device to gain control of the SCSI so that it can initiate or resume an I O process The procedure for an SCSI device to obtain control of the SCSI bus is as follows a The SCSI device shall first wait for the BUS FREE phase to occur The BUS FREE phase detected whenever both the BSY and SEL signals are simultaneously and continuously false for a minimum of a bus settle delay b The SCSI device shall wait a minimum of a bus free after detection of the BUS FREE phase i e after the BSY and SEL signals are both false for a bus settle delay before driving any signal we c 3 Following the bus free delay in Step b the SCSI device may arbitrate for the SCSI bus by asserting both the BSY signal and its own SCSI ID however the SCSI device shall not arbitrate i e assert the BSY signal and its SCSI ID if more than a bus settle delay has passed since the BUS FREE phase was last observed M 3099GX GH OEM Manual d After waiting at least an arbitration delay measured from its assertion of the BSY signal the SCSI device shall examine the DATA BUS If a higher priority SCSI ID bit is true on th
23. purpose of entering the ARBITRATION phase M 3099GX GH OEM M anual Bus Settle Delay The minimum time for wait for the bus to settle after changing certain control signals as called out in the protocol definitions Cable Skew Delay INTERFACE The maximum difference in propergation time allowed between any ao two SCSI bus signals measured between any two SCSI devices Data Release Delay The maximum time for an initiator to release the DATA BUS signals following the transition of the I O signals from false to true Deskew Delay The minimum time required for deskew of certain signals Disconnection Delay The minimum time that a target shall wait after releasing BSY before participating in an ARBITRATION phase when honoring a DISCONNECT message from the initiator Hold Time The minimum time added between the assertion of REQ or REQB or ACK or ACKB and the changing of the data lines to provide hold time in the initiator or target while using synchronous data transfers REQB and ACKB timings only apply to optional wide data transfers Negation Period The minimum time that a target shall negate REQ or REQB while using synchronous data transfers Also the minimum time that an initiator shall negate ACK or ACKB while using synchronous data transfers REQB and ACKB timings only apply to optional wide data transfers M 3099GX GH OEM M anual 3 13 Power On to Selection Time The recommended maximum time from power
24. the SELECTION phase The initiator shall the wait at least two deskew delays and release the BSY signal The initiator shall then wait at least a bus settle delay before looking for a response from the target The target shall not respond to selection if bad parity is detected Also if more than two SCSI ID bits are on the DATA BUS the target shall not respond to selection M 3099GX GH OEM M anual 3 17 No less than two deskew delays after the initiator detects the BSY signal is true it shall release the SEL signal and may change the DATA BUS The target shall wait unitl the SEL signal is false before asserting the REQ signal to enter an information transfer phase See ANSI SCSI 2 6 1 3 1 SELECTION Time out Procedure RESELECTION Phase RESELCTION is an optional phase that allows a target to reconnect to an initiator for the purpose of continuing some operation that was previously started by the initiator but was suspended by the target i e the target disconnected by allowing a BUS FREE phase to occur before the operation was completed RESELECTION Upon completing the ARBITRATION phase the winning SCSI device has both the BSY and SEL signals asserted and has delayed at least a bus clear delay plus a bus settle delay The winning SCSI device becomes a target by asserting the I O signal The winning SCSI device shall also set the DATA BUS to a value that is the logical OR of its SCSI ID bit and the initiator s SCSI ID bit The
25. to see Screen 25 The default setting is 5 G3At Screen 25 the SCSI ID isfrom 0 to 7 each time you press M ode 1 84 Press M ode 2 to see Screen 24 T he settings are stored to EEPROM 65 When you close the setup mode to 9 B3 13 Setting Product ID W hen you set the Product ID you must se as follows lt lt SETUP MODE gt gt PRODUCT ID SET Screen 26 PRODUCT ID SET X XX X X X Screen 27 GOAt Screen 2 press M ode 1 thirteen times to go to the PRODUCT ID SET screen Screen 26 87 Press M ode 2 to see Screen 27 T he default setting is M 3099GH in case of M 3099GH and M 3099G in case of M 3099G X M 3099GX GH M anual G8 At Screen 27 the Product ID may be 30996 M 3099GH or M 3096G at each time you press M ode 1 in case of M 3099GH and M 3099G or M 3096G at each time you press M ode 1 in case of M 3099G X G9 Press M ode 2 to see Screen 26 The setting are stored to EEPROM Gow hen you close the setup mode go to 9 B3 14 Setting picking starttime W hen you set the picking start time you must set as follows DAt Screen 2 press M ode 1 fourteen times to hc SETUPMODE go to the PICK START TIME screen PICK START TIMER Screen 28 Screen 28 2 ress M ode 2 to see Screen 29 T he default setting is 1 sec PICK START TIMER 1 At Screen 29 press M ode 1 until the digit XX X 5 yo
26. 16 17 18 D00 D02 D03 D04 D05 D06 D07 19 20 21 22 23 24 25 26 0001 012 0131014 1015 1016 1017 59 60 61 62 63 64 65 66 D60 D61 D62 D63 D64 D65 D66 D67 67 68 69 70 71 72 73 74 D70 D71 D72 D73 D74 D75 D76 D77 M 3099GX GH OEM M anual 3 77 Gamma Function Table 3 58 Gamma Function Data Format Bit 7 6 5 4 3 2 1 0 Byte 0 Gamma Correction Table Identifier 1 Reserved 2 Gamma Correction Table Order 3 Bit Padding Type LE ort Source Table Size 5 6 Destination Table Size 7 8 Reserved 9 Reserved 10 Gamma Correction Table Data n Gamma Correction Table Identifier O0h Black and White The gamma correction table identifier field specifies identifier to distinguish the types of Gamma Correction Table Gamma Correction Table Order 00h Reserved The gamma correction table order field specifies order of color table to be transferred to target in Gamma Correction Table Data Bit Padding Type OO0h Reserved The bit padding type field is reserved for extension of higher than 8bit data Source Table Size 0100h 255 step The source table size field specifies the range of input value to Gamma Correction Table 3 78 M 3099GX GH OEM M anual Destination Table Size 0100h 255 step The destination table size field specifies the range of output value to G
27. 2 Job Separation Sheet 3 Paper Size 4 Reserved Popp ees Job Separation Sheet 00h 80h This field indicates if job separation sheet is detected Table 3 64 Job Separation Sheet Value Description 00h Job Separation Sheet is not detected 016 7 80h Job Separation Sheet is detected 81h FFh Reserved Paper Size This field indicates detected Paper Size by the scanner 3 84 M 3099GX GH OEM Manual Table 3 65 Paper Size Value Description O0xxxxxxb Paper ejected Note 3 01xxxxxxb Paper loaded Note 3 0x0xxxxxb Paper Size is detected 0x1xxxxxb Paper Size is not detected OxxOxxxxb Portrait Note 2 Oxxlxxxxb Landscape Note 2 Oxxx0000b Reserved Oxxx0001b Reserved Oxxx0010b Reserved 0 0011 11 x17 Note 1 M3099GX Reserved M3099GH Oxxx0100b A4 or 8 5 x11 Note 1 0 0101 A5 Oxxx0110b Reserved Oxxx0111b Reserved Oxxx1000b Reserved Oxxx1001b Reserved 0 1010 Reserved Oxxx1011b B4 M3099GX Reserved M3099GH Oxxx1101b 5 0 1110 Reserved Oxxx1111b Reserved Note 1 M3099GX cannot distinguish 11 x17 and 8 5 x11 and A4 M3099GH can not distinguish 11 x17 and A3 B4 2 When this scanner load paper by OBJECT POSITION command Load Object detect paper size assuming orientation is Po
28. 5 XXX Reading counter The counter of reading paper is displayed in a batch of the reading operation 012 3 4 5 6 7 8 9 1011 12 13 M 15 16 17 18 19 20 21 22 23 5 Readxxxxxx Abrasion counter The abrasion counter is displayed after pressing STOP switch in the Ready screen In following case the display of counter is deleted The next Start Command is issued The valid switches are pressed The error is cleared IPC pre set mode 012 3 4 5 6 7 8 9 101 12 13 M 15 16 17 18 19 20 21 22 23 5 When IPC II pre set mode is set an asterisk is displayed The method of IPC II pre set mode is show in setup mode M 3099GX GH OEM M anual Buttons Manual button This button is used to select manual feed mode By pressing this button setting is switched between Manual mode and ADF mode By pressing this button scanner goes to manual feed mode and the hopper elevates The next pressing this button scanner exit from manual feed mode and the hopper down BASIC OPERATION Start Stop button This button are used in Off line mode By pressing Start button in Off line mode the scanner starts document feeding By pressing Stop button in Off line mode the scanner stops document
29. Additional Sense Length OAh 10 bytes This field indicates the number of additional sense bytes to follow If the allocation length of the command descriptor block is too small to transfer all of the additional sense bytes the additional sense length is not adjusted to reflect the truncation Command Specific Information 00000000 supported ASC Additional Sense Code This field indicates further information related to the error or exception condition reported in the sense key field The additional sense code qualifier ASCQ indicates detailed information related to the additional sense code Field replaceable unit code 00h not supported Sense Key specific bytes 000000h not supported The additional sense bytes field may contain command specific data peripheral device specific data or vendor specific data that further defines the nature of the CHECK CONDITION status M 3099GX GH OEM M anual 3 53 Table 3 30 Implementation of SK Sense Key ASC Additional Sense Code ASCO Additional Sense Code Qualifier Hierachy Sense Additional Additional Description key Sense Code Sense Code Qualifier 00h 00h No Sense 00h 00h Not Ready 80h 01h Interlock Switch Is Opened 3 1806 01h Jam 1 02h ADF Cover Open 03h Chuter Out Of Paper 04h Job Separation Sheet detected 80h 08h Roller unit not set 80h 10h Print Head on Endorser
30. Byte Bit 7 6 5 4 3 2 1 0 Reserved Status Byte Code Reserved Table 3 81 Status Byte Code Bits of Status Byte Status 76543210 RRO 0 0 0 0 RJ GOOD Supported RRO 00 0 1 CONDITION Supported RRO O01 0 MET RRO 0 1 0 0 R BUSY Supported RRO 1 0 0 0 RIINTERMEDIATE RRO 1 0 R JINTERMEDIATE CONDITION MET RRO 1 1 0 0 RESERVATION CONFLICT Supported 0 0 0 1 TERMINATED RR 1 0O 1 0 0 FULL All Other Code Reserved Key R Reserved bit M 3099GX GH OEM M anual 3 97 definition of the status byte codes is given below GOOD This status indicates that the target has successfully completed the command CHECK CONDITION This status indicates that a contingent allegiance condition has occurred See ANSI SCSI 2 7 6 BUSY This status indicates that the target is busy This status shall be returned whenever a target is unable to accept a command from an otherwise acceptable initiator i e no reservation conflicts The recommended initiator recovery action is to issue the command again at a later time RESERVATION CONFLICT This status shall be returned whenever an initiator attempts to access a logical unit or extent within a logical unit that is reserved with conflicting reservation type for another SCSI device See RESERVE UNIT RESERVE UNIT commands The recommended initiator recovery action is to i
31. C D I O and MSG signals during the REQ ACK handshake of this phase STATUS Phase The STATUS phase allows the target to request that status information be sent from the target to the initiator The target shall assert the C D and I O signals and negate the MSG signal during the REQ ACK handshake of this phase Message Phase The message phase is a term that references either a MESSAGE IN or a MESSAGE OUT phase Multiple messages may be sent during either phase The first byte transferred in either of these phases shall be either a single byte message or the first byte of a multiple byte message Multiple byte messages shall be wholly contained within a single message phase MESSAGE IN Phase The MESSAGE IN phase allows the target to request that message s be sent to the initiator from the target The target shall assert the C D I O and MSG signals during the REQ ACK handshake s of this phase M 3099GX GH OEM M anual 3 23 SCSI Bus Conditions MESSAGE OUT Phase See ANSI SCSI 2 6 1 9 2 for details The MESSAGE OUT phase allows the target to request that message s be sent from the initiator to the target The target invokes this phase in response to the attention condition created by the initiator The target shall assent the C D and MSG signals and negate the I O signal during the REQ ACK handshake s of this phase The target shall handshake byte s in this phase until the ATN signal is negated except when reject
32. Endorser String The Endorser String Length of zero is not considered as error The maximum printable string length in this scanner is 20 columns including endorser counter value This scanner supports only 05ud for endorser counter format This field can be exceeded 20 because of 96906 is two characters but it is recognized 96 as one character Endorser Strings field specifies Endorser Strings to be printed Alpha numeric ASCII code 20h to 7Fh and Endorser counter is available This field uses C language printf syntax Only one numerical argument is available and any escape sequences are not available ex Number of Page 9605ud 20column Endorser counter is used as numerical argument implicitly M 3099GX GH OEM M anual Status See ANSI The status byte and status byte code are defined in Table 3 80 3 81 SCSI 2 7 3 status byte shall be sent from the target to the initiator during the STATUS phase at the completion of each command unless the command is terminated by one of the following events a an ABORT message b an ABORT TAG message ABORT TAG is not supported by EIE this scanner Fo c a BUS DEVICE RESET message d a CLEAR QUEUE message CLEAR QUEUE is not supported by this scanner a hard reset condition f an unexpected disconnect The STATUS phase normally occurs at the end of a command but in some case may occur prior to transferring the command descriptor block Table 3 80 Status
33. L Very Good Poor What is your overall rating of this publication Fair Very Poor What is your occupation Your other comments may be entered here Please be specific and give page paragraph and line number references where applicable Your Name amp Return Address M 3099GX GH OEM M anual Clean
34. M3096G M3097G Notations ARB SEL CMD DI MI MO STS BF Init Targ ARBITRATION phase SELECTION phase COMMAND phase DATA IN phase MESSAGE IN phase MESSAGE OUT phase STATUS phase BUS FREE Initiator Host Computer Target Image Scanner Variables for explanation TL WD VD M N TD Requested Transfer Length size bytes Window Data size defined by SET WINDOW command bytes If compression is specified the size is compressed data Scanned image data size in scanner memory bytes This value is varied on scanning progression Transferred data size bytes N VD div 65536 bytes Total Data that is transferred bytes When TL 2 WD at first READ command it is called Single READ sequence This scanner has default page buffer memory therefore the Single READ is completely subset of Multiple READ This document has omitted Single READ sequence 3 118 M 3099GX GH OEM M anual Multiple READ disconnect disabled TD 0 ARB Init SEL Init Targ MO IDENTIFY CMD READ TL lt WD DI Image Data TL TD4 TL EO 1 515 CHECK CONDITION STS GOOD MI COM M AND COM PLETE MI COM M AND COM PLETE BF BF Read End See Note 1 2 M 3099GX GH OEM M anual 3 119 INTERFACE Multiple READ disconnect enabled This sequence is intend
35. Olh Dither 02h Error Diffusion INTERFACE 03h to FFh Reserved Halftone pattern 00h to 03h resident 80h to 87h downloaded Halftone Pattern field specifies arguments of halftone type This field is defined for Halftone Type Dither as shown in Table 3 40 For other halftone type this field is reserved Table 3 40 Halftone Pattern Value Halftone pattern 00h Dither pattern 0 01h Dither pattern 1 02h Dither pattern 2 03h Dither pattern 3 04h to 7Fh Reserved 80h to 87Fh Downloaded Pattern 85h to FFh Reserved Reverse Image Format RIF Ob Ib with IPC2 reverse image format RIF bit of zero inidicates that white pixels are to be indicated by zeros and black pixels are to be indicated by ones RIF bit of one indicates that white pixels are to be indicated by ones and black pixels are to be indicated by zeros The RIF bit is applicable only for images represented by one bit per pixel Padding Type 00h no padding The padding type field specifies how the target shall pad the image data transmitted to the initiator if it is not an integral number of bytes M 3099GX GH OEM M anual 3 63 Ordering 0000h not supported The bit ordering field is not supported Compression Type Compression Argument Table 3 41 The compression type and compression argument fields specify the compression technique to be applied to the image data see Table 3 41 T
36. READY Command eee 3 32 INQUIRY Command See ANSI SCSI 2 7 2 5 3 32 Standard INQUIRY Data See ANSI SCSI 2 7 2 5 1 3 34 M 3099GX GH OEM M anual Vital Product Data esee 3 37 REQUEST SENSE Command See ANSI SCSI 2 8 2 14 3 49 SEND DIAGNOSTIC igit 3 55 SEI WINDOW Command 3 56 Vendor Unique Parameters uoo 3 65 OBJECT POSELFION iiiter E EET RERE 3 73 SEND Command 3 74 SCAN Command 3 79 READ Command 3 80 MODE 6 Command ee 3 86 MODE SENSE 6 Command eee 3 87 Mode Parameter 3 88 ENDORSER Command ENDORSER option is required 3 92 Status See ANSI SCSI 2 7 3 entrino 3 97 Message See ANSI SCSI 2 6 5 3 99 ABORT nit gt Targ 3 102 BUS DEVICE RESET nit gt Targ 3 103 COMMAND COMPLETE Init lt Targ iicet 3 103 DISCONNEBGT nit Targ 3 103 IDENTIFY nik escolar 3 104 INITIATOR DETECTED ERROR Init gt Targ 3 105 MESSAGE PARITY ERROR Init 3 105 MESSAGE REJECT Init gt 3 106 3 106 RESTORE POINTERS nite Targ 3 107 SAVE DATA POINTER Init Tate sessions 3 107 SYNCHRONOUS DATA TRANSFER REQUEST 3 107 iere 3 110 Syster Initialization ue itr erts 3
37. REQ ACK handshake of the message byte that has the parity error This provides an interlock so that the target can determine which message byte has the parity error If the target receives this message under any other circumstance it shall signal a catastrophic error condition by releasing the BSY signal without any further information transfer attempt If after receiving the MESSAGE PARITY ERROR message the target returns to the MESSAGE IN phase before switching to some other phase the target shall re send the entire message that had the parity error M 3099GX GH OEM M anual 3 105 MESSAGE REJECT Init lt gt Targ The MESSAGE REJECT message is sent from either the initiator or target to indicate that the last message or message byte it received was inappropriate or has not been implemented In order to indicate its intentions of sending this message the initiator shall assert the ATN signal prior to its release of the signal for the REQ ACK signal for the REQ ACK handshake of the message byte that is to be rejected If the target receives this message under any other circumstance it shall reject this message When a target sends this message it shall change to MESSAGE IN phase and send this message prior to requesting additional message bytes from the initiator This provides and interlock so that the initiator can determine which message byte is rejected After a target sends a MESSAGE REJECT message and if the
38. Resolution LSB 6 7 MSB Basic Y Resolution LSB 8 9 Res Step X Res Step Y 10 MSB Maximum X Resolution LSB 11 12 MSB Maximum Y Resolution LSB 13 14 MSB Minimum X Resolution LSB 15 16 MSB Minimum Y Resolution LSB 17 18 MSB Standard Resolution LSB 19 20 MSB Window Width LSB poem aded 24 MSB Window Length LSB 28 Function 29 Reserved 30 Vendor Unique Parameter Byte s 3 38 M 3099GX GH OEM M anual Peripheral Device Page Number Version Page Length Basic X Resolution Basic Y Resolution Res Step X Res Step Y Maximum X Resolution Maximum Y Resolution Minimum X Resolution Minimum Y Resolution Standard Resolution OGh Image Scanner FOh Page Code 02h JBMS 0 2 95 m 100 200 200dpi 200 200dpi 00h Variable Resolution OOh Variable Resolution 400 400dpi with without IPC2 400 400dpi with without IPC2 200 without IPC2 50 with IPC2 200 without IPC2 50 with IPC2 01DOh without IPC2 FFFOh with IPC2 This field indicates available resolution bit is set as as described in Table 3 14 This is applied to only for main scan direction Table 3 14 Standard Resolution unit Pixel Inch Bit 7 6 5 4 3 2 1 0 Byte 17 60 75 100 120 150 160 180 200 18 240 300 320 400 480 600 800 1200 Window Width 00000980h 2432 dot for M3099GX 000006CO0h 1728dot for M3099GH Window Le
39. Separation Sheet The Page Code fields identifies the format and parameters defined for that mode page This scanner supports 3Dh Lamp Timer 3Eh Job Separation Sheet The page length field specifies the length in bytes of the mode parameters that follow If the initiator does not set this value to the value that is returned for the page by the MODE SENSE command the target shall terminate the command with CHECK CONDITION status The sense key shall be set to ILLEGAL REQUEST with the additional sense code set to INVALID FIELD IN PARAMETER LIST The target is permitted to implement a mode page that is less than the full page length defined by this standard provided no field is truncated and the page length field correctly specifies the actual length implemented a Lamp Timer page The Lamp Timer page provides to adjust the Turn Off time of fluorescent lamp Table 3 72 Lamp Timer page Bit 7 6 5 4 3 2 1 Byte 0 Reserved Page Code 3Dh 1 Page Length 06h 2 Lamp Timer 3 Reserved L 2 PRIME Lamp Timer 0 to 255 second This field specifies the fluorescent lamp turn off time in second after scanning 0 specifies default time 60 seconds 1 through 255 seconds can be specified 3 90 M 3099GX GH OEM M anual Job Separation Sheet Parameter 00h Disable 80h Enable b Job Separation Sheet page Table 3 73 Job Separation Sheet page
40. WARNING Wait at least 3 minutes after turning off the power before touching the lamp 4 10 M 3099GX GH M anual Replacing front side lamp Uppertransportunit Operator panel Turn off the power switch 2 Open the upper transport unit See page 4 2 BASIC OPERATION Lever Power switch Lamp socket covers 3 Remove the two lamp socket covers U shaped spring clips by pulling them out of their positions 4 Rotate the lamp so that the two terminals on each and align with the exit slot on the lamp socket Maintain the alignment and remove the lamp from the lamp sockets CAUTION Be careful not to pull the wire of the heater hard M 3099GX GH OEM M anual 4 11 Window Cross sectional view of lamp 5 Separate the C shaped heater assembly from the lamp body gently CAUTION Be careful not to peel the tape on the heater assembly If any visible damage on the heater assembly is observed please contact manufacturer s authorized service center for proper repair service 6 Re attach a new lamp to the C shaped heater Note Position the lamp so that the following lengths are the same al a2 b b2 4 12 M 3099GX GH OEM M anual 7 reinstall lamp heater reverse procedures in item above Socket Front N ote W hen re stalling the lamp make sure to rotate the lamp in the direction as shown in the left figure BASIC
41. application until an SCSI target is able to respond with appropriate status and sense data to the TEST UNIT READY INQUIRY and REQUEST SENSE commands Reset to Selection Time The recommended maximum time after a hard RESET condition until an SCSI target is able to respond with appropriate status and sense data to the TEST UNIT READY INQUIRY and REQUEST SENSE commands Reset Hold Time The minimum time for which RST is asserted There is no maximum time Selection Abort Time The maximum time that a target or initiator shall take from its most recent detection of being selected or reselected until asserting a BSY response This time out is required to ensure that a target or initiator does not assert BSY after a SELECTION or RESELECTION phase has been aborted This is not the selection time out period see ANSI SCSI 2 6 1 3 1 and ANSI SCSI 2 6 1 4 2 for a complete description Selection Time out Delay The minimum time that a SCSI device should wait for a BSY response during the SELECTION or RESELECTION phase before starting the time out procedure Note that this is only a recommended time period 3 14 M 3099GX GH OEM M anual Transfer Period The Transfer Period specifies the minimum time allowed between the leading edges of successive REC pulses and of successive ACK pulses while using synchronous data transfers See ANSI SCSI 2 6 1 5 2 and ANSI SCSI 2 6 6 21 INTERFACE SCSI Bus Phases The SCSI arc
42. be a NOT READY sense key or another unexpected error TEST UNIT READY 5 This TEST UNIT READY command is used to see if all outstanding CHECK CONDITION statuses have finally been cleared If so the logical unit is identified as ready REQUEST SENSE 6 This REQUEST SENSE command is used to determine why there is a persistent CHECKCONDITION status If the sense key indicates some other failure the logical unit is identified as failing and the sense key is logged in the appropriate area IMPLEMENTORS NOTE Commands that receive BUSY or RESERVATION CONFLICT status should be re issued until some other status is received 3 114 M 3099GX GH OEM M anual Scanning Sequence Basic Scanning Sequence Simplex Mode RESERVE UNIT SET WINDOW ID 00h Load Object SCAN ID 00h 1 1 1 ECT POSITION 1 l 1 1 l 1 1 1 1 ECT POSITION Unload Object RELEASE UNIT Reserve exclusive use ofthe scanner INTERFACE Specify document scanning parameter Send Halftone M ask and or Gamma Function data if required Feed document into ADF This command is omissible because SCAN or READ command automatically feeds in a document Start scanning operation This command is omissible because READ command automatically starts scanning Transfer image data from scanner READ command would be issued one or more The detail
43. check 43h 00h MESSAGE ERROR 4 1444 00h Internal Target Failure 80h 01h FB Motor Fuse Blown 02h Heater Fuse Blown 03h Lamp Fuse Blown 04h ADF Motor Fuse Blown 05h Mechanical System Failure 06h Optical System Failure 80h 10h Endorser Failure 80h 11h Endorser Fuse Blown 5 20h 00h INVALID COMMAND OPERATION CODE 24h 00h INVALID FIELD IN CDB 25h 00h LOGICAL UNIT NOT SUPPORTED 26h 00h INVALID FIELD IN PARAMETER LIST 2Ch 02h INVALID COMBINATION OF WINDOWS SPECIFIED If this unit detects double feed status while the double feed detection function is validated for GH G a paper jam is reported to the host M 3099GX GH OEM M anual Table 3 30 Implementation of SK Sense Key ASC Additional Sense Code ASCO Additional Sense Code Qualifier Hierachy continued Sense Additional Additional Description key Sense Code Sense Code Qualifier 6 00h 00h Unit Attention INTERFACE 47 00h SCSI Parity Error 80h Olh Image Transfer Error SEND DIAGNOSTIC Command The SEND DIAGNOSTIC Command Table 3 31 requests the target to perform diagnostic operations on itself on the logical unit or on both This scanner supports only the self test feature with the parameter list length of zero Table 3 31 SEND DIAGNOSTIC Command Bit 7 6 5 4 3 2 1 0 Byte 0 Operation Code 1Dh 1 Logical Unit Number PF Reserved SelfTest DevOfL Uni
44. document sensor unit and keep the unit open 3 Wipe the top of the four sensors with a dray cloth or cloth soaked in isopropyl alcohol M 3099GX GH OEM M anual 8 7 4 Closethe document sensor unit 5 Closethe upper transport unit See page 4 2 Document detection sensor Clean the document detection sensor as follows 1 Open the upper transport unit See page 4 2 2 H old the handles of the document sensor unit and keep the unit open 3 Wipe the two sensor windows a and b with a dry cloth or cloth soaked in isopropyl alcohol 4 Closethe document sensor unit 5 Closethe upper transport unit See page 4 2 8 8 M 3099GX GH M anual Reading timing sensor Clean the reading timing sensor as follows T Open the upper transport unit See page 4 2 2 Wipe the sensor top of sensor at the transport path of the upper transport unit with a dry cloth or cloth soaked in isopropyl alcohol 3 Close the upper transport Lam Sensor j unit See page 4 2 Ejection sensor Clean the ejection sensor as follows D Open the upper transport CLEANING unit See page 4 2 2 Wipe the top of sensor at the rear center of the device with a dry cloth or cloth soaked in isopropyl alcohol Sen
45. errors If the document slips in ADF JAM error or double feed occurs separation pressure adjustment of Appendix C may be effective CAUTION Never use an original document on this machine Paper has clip Paper has ink etc is not dry 6 2 M 3099GX GH OEM M anual e Paper thickness is not constant like envelope Paper has large rumples or curl See Note in next page Paper has folds or tears Tracing paper Coating paper Carbon paper Carbonless paper Paper size smaller than 76 mm x 63 mm size or larger than A3 width Other than paper clothes metal foil or OHP film Photographic paper Paper has notches on its side Shape is other than square DOCUMENT Do not feed important original document so as not damage it in rare case When scanning a translucent document set the density to light mode To prevent roller smudging avoid scanning a document filled out in pencil Clean the roller as often as possible when scanning many document Once every 1000 pages is recommended The chemical composition of some carbonless papers reacts with the roller rubber and damages the rubber Check the carbonless papers before use The carbonless papers may be used if 1 Ream weight is 44 kg 12 lb or more 2 Hopper load is 500 sheets or fewer M 3099GX GH OEM M anual 6 3 Note f carbonless papers are used clean the roller twice as often as usual Paper should be straightend to fit th
46. feeding The Stop button is also used in On line mode to cancel temporary error condition Mode 1 button This button is used to transit to Off line SETUP mode when Power on By pressing Mode 1 button and turn on the Power switch this scanner starts up in SETUP mode Mode 2 button This button is used to transit to Off line TEST mode when Power on By pressing Mode 2 button and turn on the Power switch this scanner starts up in TEST mode The TEST mode is used for maintainance diagnostic purpose Functions are described in M3099G IMAGE SCANNER CE MANUAL M 3099GX GH OEM M anual 4 7 Message List Table 4 3 lists the messages indicating scanner statuses temporary errors and equipment errors in the On line mode The error conditions and how to recover are described in Chapter 5 ERROR PROCESSING AND RECOVERY Table 4 3 Messages Item Message Power On Warming up Now Ready Scanner Ready Warning INK EMPTY Temporary errors HOPPER EMPTY COVER OPEN MISS PICK ROLLER UNIT NOT SET PRINT HEAD NOT SET PRINT HEAD ALARM HOPPER OVERLOAD Equipment errors HOPPER ALARM TRANSPORT ALARM LAMP ALARM 1 HEATER ALARM 1 LAMP ALARM 2 HEATER ALARM 2 CCD UNIT ALARM 1 CCD UNIT ALARM 2 TEMP ALARM FUSE ALARM PRINT RAM ALARM PRINT TIME OUT ALARM PRINT HARDWARE ALARM 1 These messages are displayed when END
47. of pointers SYNCHRONOUS DATA TRANSFER REQUEST Table 3 87 SYNCHRONOUS DATA TRANSFER REQUEST Bit 7 6 5 4 3 2 0 Byte 0 Extended message 01h 1 Extended message length 03h 2 SYNCHRONOUS DATA TRANSFER REQUEST code 01h 3 Transfer Period Factor 4 REQ ACK Offset M 3099GX GH OEM M anual 3 107 INTERFACE A SYNCHRONOUS DATA TRANSFER REQUEST SDTR message Table 3 87 exchange shall be initiated by an SCSI device whenever a previously arranged data transfer agreement may have become invalid T he agreement becomes invalid after any condition which may leave the data transfer agreement in an indeterminate state such as a after a hard reset condition b after a BUS DEVICE RESET message and c after a power cycle In addition an SCSI device may initiate an SDTR message exchange whenever it is appropriate to negotiate a new data transfer agreement either synchronous or asynchronous SCSI devices that are capable of synchronous data transfers shall not respond to an SDTR message with a MESSAGE REJECT message The SDTR message exchange establishes the permissible transfer periods and the REQ ACK offsets for all logical units on the two devices This agreement only applies to data phases Transfer Period Factor 62 4MB s max to 255 The transfer period factor times four is the value of the transfer period The transfer period is the minimum time allowed between leadi
48. readed image is symmetrically flipped to produce a mirror image of the original detected in the main scanning direction Noise removal Isolated noise from an image appearing as black spots in white areas and voids in black areas is removed to improve image quality M 3099GX GH OEM M anual GL 3 Operator panel A panel containing the scanner indicators and buttons The operator panel is used to control scanner operations such as loading document selecting features and changing setup options Outline extraction The boundary between black and white areas is traced and the outline extracted for closed areas RS 232C interface A type of serial interface See Serial interface Serial interface A standard computer interface Information is transferred between devices over a single wire although other wires are used for control With a serial interface an interface cable greater than 3 meters 10 feet can be used This is often necessary in networking environments where the scanner may be shared Smoothing Smoothing eliminates jaggies from slanted lines and curves Irregular convexities are deleted and irregular concavities filled in This is useful in OCR applications for example Temporary error A status which the operator can recover such as paper jam hopper empty cover open pick miss GL 4 M 3099GX GH OEM M anual Cleaning Locations and Frequencies 8 1 Cleaning the glass surface 8 7 Cleaning the
49. signal is still asserted then it shall return to the MESSAGE OUT phase The subsequent MESSAGE OUT phase shall begin with the first byte of a message NO OPERATION Init Targ The NO OPERATION message is sent from an initiator in response to a target s request for a message when the initiator does not currently have any other valid message to send For example if the target does not respond to the attention condition until a later phase and at that time the original message is no longer valid the initiator may send the NO OPERATION message when the target enters the MESSAGE OUT phase 3 106 M 3099GX GH OEM M anual RESTORE POINTERS Init Targ The RESTORE POINTERS message is sent from a target to direct the initiator to copy the most recently saved command data and status pointers for the I O process to the corresponding current pointers The command and status pointers shall be restored to the value at the beginnings of the data area in the absence of SAVE DATA POINTER message or to the value at the point at which the last SAVE DATA POINTER message occurred for that nexus This scanner sends this message only when received a INITIATOR DETECTED ERROR during image data transfer SAVE DATA POINTER Init Targ The SAVE DATA POINTER message is sent from a target to direct the initiator to copy the current data pointer to the saved data pointer for the current I O process ANSI SCSI 2 6 4 for a definition
50. support Grayscale RGB Color set this bit to 1 Scanners do not support Grayscale RGB Color set this bit to 0 Steps of gray is not specified Data Over Flow means when receipt of data by the initiator is too slow data buffer of image scanner is filled and data is not guranteed Fujitsu further defines own Vital Product Data using Vendor Specific field of JBMS This extended Vital Product Data is used by Device Driver to confirm which functions are supported Current defined data is totally 100 bytes but it will be expanded by future functions M 3099GX GH OEM M anual Table 3 16 Standard VPD Page Extended Format Bit 7 6 5 4 3 2 1 0 Byte 30 Reserved 31 Reserved 32 1 5 Physical Function 33 LSB 34 MSB Buffering Capability 37 LSB 38 MSB Implemented Standard Command 41 LSB 42 Implemented Vendor Specific Command 49 Mh 50 Implemented Vendor Unique Parameter 81 82 Image Control Function 87 HE 88 Image Processing Function 89 mM 90 Compression Function 91 92 Endorser Function 93 MM 94 Barcode Function 97 95 Reserved 100 M 3099GX GH OEM M anual 3 4 Physical Function 10010010 00001000b without ENDORSER 10011010 00001000b with ENDORSER Physical Function field of each bit indicates Physical variated functions
51. target shall wait at least two deskew delays and release the BSY signal The target shall wait at least a bus settledelay before looking for a response from the initiator The initiator shall determine that it is reselected when the SEL and I O signals and its SCSI ID bit are true and the BSY signal is false for at least a bus settle delay The reselected initiator may examine the DATA BUS in order to determine the SCSI ID of the reselecting target The reselected initiator shall then assert the BSY signal within a selection abort time of its most recent detection of being reselected this is required for correct operation of the time out procedure The initiator shall not respond to a RESELECTION phase if bad parity is detected Also the initiator shall not respond to a RESELECTION phase if other than two SCSI ID bits are on the DATA BUS M 3099GX GH OEM M anual After the target detects the BSY signal is true it shall also assert the BSY signal and wait at least two deskew delays and then release the SEL signal The target may then change the I O signal and the DATA BUS After the reselected initiator detects the SEL signal is false it shall release the BSY signal The target shall continue asserting the BSY signal until it relinquished the SCSI bus See ANSI SCSI 2 6 1 4 2 RESELECTION Time out Procedure Information Transfer Phases NOTE The COMMAND DATA STATUS and MESSAGE phases are all grouped together as the information t
52. to be transfered usually number of blocks The block length is this scanner is byte In command that use multiple bytes for the transfer length a transfer length of zero indicates that no data transfer shall take place A value of one or greater indicates the number if blocks that shall be transferred Allocation Length The allocation length field specifies the maximum number of bytes that an initiator has a allocated for returned data An allocation length of zero indicates that no data shall be transferred This condition shall not be considered as an error The target shall terminate the DATA IN phase when allocation length bytes have been transferred or when all available data have been transferred to the initiator whichever is less The allocation length is used to limit the maximum amount of data e g sense data mode data etc returned to initiator Control field The control field is the last byte of every command descriptor block The control field is defined in ANSI SCSI 2 7 2 7 In this scanner this field is not used Any field in this byte is regarded as Reserved M 3099GX GH OEM M anual Table 3 7 Operation Code Types Command Operation Description Code hex RESERVE UNIT 16 Reserve a logical unit RELEASE UNIT 17 Release a previously reserved logical unit INQUIRY 12 Requests information regarding parameters of target and its attached peripheral device s REQUES
53. type fields identify the device currently connected to the logical unit If the target is not capable of supporting a device on this logical unit this field shall be set to 7Fh peripheral qualifier set to 011b and peripheral device type set to Peripheral Qualifier 000b Connected Peripheral Device Type O6h Scanner Device RMB Removable Medium Bit Ob not supported Device Type Modifier 0000000b not supported ISO Version 00b does not claim compliance with ISO ECMA Version 000b does not claim compliance with ECMA ANSI Approved Version 2h SCSI 2 if approved AENC Asynchronous Event Notification Capability Ob Reserved TrmlIOP Terminate I O Process Ob not supported see ANSI SCSI 2 5 6 22 Response Data Format 2h INQUIRY Data Format is defined in SCSI 2 Additional Length 91 n 95 This field shall specify the length in bytes of the parameters If the allocation length of the command descriptor block is too small to transfer all of the parameters the additional length shall not be adjusted to reflect the truncation RelAdr Relative Addressing Ob not supported Wbus32 Wide Bus 32 Ob not supported Whbusl16 Wide Bus 16 Ob not supported Sync Synchronous Transfer lb synchronous transfer supported Linked Linked Command Ob not supported CmdQue Command Queuing Ob not supported SftRe Soft Reset Ob Hard Reset Vendor Identification FUJITSU 3 36 M 3099GX GH OEM M anual
54. were selected to provide approximately 10mA Iquiescent The voltage regulator Vdropout shall be 1 25V or less at Imax 2 Alternative values that provide lower performance at somewhat lower cost use Vout 1 R3 R20 100 0 290 Figure 3 3 Alternative 2 termination for Single Ended Devices The first termination method above is the same as in SCSI 1 The second termination method is recommended for better signal quality M 3099GX GH OEM M anual 3 5 Connector pin assignments Table 3 2 Single Ended Contact Assignment A Cable Signal Connector Cable Connector Signal Name Name Contact Connector Contact Number Set 2 Number Number Set 2 GROUND 1 1 2 26 DB 0 GROUND 2 3 4 27 DB 1 GROUND 3 5 6 28 DB 2 GROUND 4 7 8 29 DB 3 GROUND 5 9 10 30 DB 4 GROUND 6 11 12 31 DB 5 GROUND 7 13 14 32 DB 6 GROUND 8 15 16 33 DB 7 GROUND 9 17 18 34 DB P GROUND 10 19 20 35 GROUND GROUND 11 21 22 36 GROUND GROUND 12 23 24 37 RESERVED OPEN 13 25 26 38 TERMPWR GROUND 14 27 28 39 RESERVED GROUND 15 29 30 40 GROUND GROUND 16 31 32 41 ATN GROUND 17 33 34 42 GROUND GROUND 18 35 36 43 BSY GROUND 19 37 38 44 GROUND 20 39 40 45 RST GROUND 21 41 42 46 MSG GROUND 22 43 44 47 SEL GROUND 23 45 46 48 C D GROUND 24 47 48 49 REQ GROUND 25 49 50 50 I O 3 6 M 3099GX GH OEM M anual Note The minus sign next t
55. will be set to NO SENSE but by checking EOM bit completion of transfer can be detected EOM 0 Image data transfer is not completed EOM 1 Image data transfer has just completed Above specification is described in JBMS but it is not recommended for speed performance reason 3 After all image data of the window is transferred CHECK CONDITION status will be returned following each READ commands To scan another document issue SET WINDOW command and set window 4 Enabling or disabling disconnection is depending on IDENTIFY message related to READ command If bit 6 of IDENTIFY message is 1 disconnection is enabled If bit 6 of IDENTIFY message is 0 disconnection is disabled M 3099GX GH OEM M anual 3 121 Status Transition of Logical Unit Power ON Reset BUS DEVICE RESET message d UNIT ATTENTION status S GOOD status CHECK CONDITION status Status transition PATEE E E E i INQUIRY command REQUEST SENSE command UNIT ATTENTION reported cleared Range protected in reserved status NOT READY status Time to READY Other command At room temperature 25 C 60 seconds Atlow temperature NOT READY status REQUEST SENSE Command NOT READY reported V d SZ READY status W aiting READ command 5 C 5 minutes Normal status Other command Reading Scan compl
56. you press the Mode 2 at Screen 12 IPC 2 pre set mode can be used Host Set Ignore and the setting number is stored to gee ea ee ee E EEPROM No Model Yes Mode 2 When you close the setup mode go 9 Screen 12 lt Classification of user s paper gt User s paper are classified in line art scanning as follows The horizontal axis shows the background density color of paper The vertical axis shows the density of character line CD 5 are the pattern number set Background density Background color in setup mode Normale Dark Red Green Blue D Normal background and Normal character Character T Normal background and densi light character ensity jr Dark background and normal density character Light Q Light character on red paper 9 Light character on green paper SETUP MODE Notice 1 For patterns 1 to 5 when the power is turned on Check that IPC 2 for front back sides are installed during initialization If IPC 2 for either the front or back side is not installed the scanner regards as no setting obligatory and changes the memory of EEPROM 2 When IPC 2 pre set is executed in setup mode Check that IPC 2 for front back sides are installed when the scanner enters in IPC 2 pre set If IPC 2 for either the front or back side is not installed the scanner does not enter in IPC 2 pre set 3 When IPC
57. 00b with ENDORSER Endorser Function field of upper 4bit indicates available endorser functions and lower 4bit indicates maximum Endorser Identifiers Table 3 26 Endorser Function Byte Bit Description 92 1XXXXXXXb Mechanical Endorser X1XXXXXXb Stamper XX1XXXXXb Electrical Endorser XXX1XXXXb Reserved XXXXnnnnb Maximum Endorser Identifiers 93 00000000b Reserved Barcode Function 00000000 00000000 00000000 00000000b Barcode Function field is reserved M 3099GX GH OEM M anual REQUEST SENSE Command ANSI SCSI 2 8 2 14 The REQUEST SENSE command Table 3 27 requests that the target transfer sense data to the initiator Table 3 27 REQUEST SENSE Command Bit 7 6 5 4 3 2 0 Byte 0 Operation Code 03h 1 Logical Unit Number Reserved 2 Reserved 3 Reserved 4 Allocation Length 5 Control The sense data 1 shall be available if a contingent allegiance condition exists for the 2 shall be available if other information is available in any field 3 may be available if an unexpected disconnect occurred I T x nexus If the target has no other sense data available to return it shall return a sense key of NO SENSE and an additional sense code of NO ADDITIONAL SENSE INFORMATION The sense data shall be preserved by the target for the initiator until retrieved by a REQUEST SENSE command or until the receipt of an
58. 1 lt ULX W lt 14592 then 0 ULY L 19842 A3 length Brightness 0 to 255 The brightness field specifies the level of brightness used to scan the object A value of zero specifies the default brightness Any other value indicates a relative brightness setting with 255 being the highest setting one being the lowest setting and 128 being the nominal setting The brightness effects for Halftone image 3 60 M 3099GX GH OEM M anual Table 3 35 Brightness Value Brightness 00h Default same to 80h Olh Brightest Normal INTERFACE FFh Darkest Threshold 0 to 255 The threshold field specifies the threshold at which scan data is converted tobinary data A value of zero specifies the default threshold at automatic threshold control if it is supported Any other value indicates a relative threshold setting with 255 being the highest setting one being the lowest setting and 128 being the nominal setting The threshold effects for Line Art image Table 3 36 Threshold Value Threshold 00h Default same to 80h Dynamic Threshold or Simplified Dynamic Threshold Olh Brightest 80h Normal FFh Darkest Contrast 0 to 255 The contrast field specifies the level of contrast used to scan the object Avalue of zero specifies default contrast or automatic contrast if it is supported Any other value indicates a relative contrast setting with 255 being the hig
59. 110 General Procedure for Initializing Devices 3 111 Verify State 3 112 SCAMMING SEQUENCE seres ereis reteta E EEEE NS 3 115 Basic Scanning Sequence Simplex Mode 3 115 Dupler Seating noe EB e tieu a 3 116 Endorser 3 117 READ command sequences and phase progression 3 118 Multiple READ disconnect disabled 3 119 Multiple READ disconnect enabled 3 120 M 3099GX GH OEM M anual 4 BASIC OPERATION cedo 4 1 Power Switch Operation P re Hb 4 1 Opening the Upper Transport Unit 4 2 Closing the Upper Transport 4 2 e 4 3 Operator panel qb pA aeta 4 3 ECD display 4 5 4 7 Message 4 8 Loading Document cud oiii Uy paret pone anori a a 4 9 Lamp Replacement oH 4 10 Roller ASY We lice tri 4 16 Pick Roller Beplaeetteh oec ten Rodez dut 4 18 4 19 4 21 5 ERROR PROCESSING AND RECOVERY 5 1 Device and Operator Actions for Temporary Errors 5 1 Device and Operator Actions for Equipment Errors
60. 2 3 4 5 6 7 8 9 10 se Bit Order MSB Byte 0 LSB MSB Byte 1 in Byter 7 6 5 4 3 2 1 017 6 5 3 82 M 3099GX GH OEM M anual Bi level or Dithered Halftone Black and White Raster 0 0 0 7 0 8 0 15 0 x 7 0 x 0 Byte 0 Byte 1 Byte x 8 Raster 1 0 1 7 1 8 1 15 1 x 7 1 x 1 Byte x 8 1 Byte x 8 2 Byte 2x 8 Raster y 1 0 y 1 7 y 1 8 y 1 15 y 1 1 1 1 Byte y 1 8 1 Byte 1 8 2 Byte y x 8 Pixel Size Data DATA TYPE CODE 80h This data can be obtained only before reading image data which is set by SET WINDOW command The number of pixels can be calculated by formula as below Number of X pixels X Resolution x Width 1200 Number of Y pixels Y Resolution x Length 1200 These values are not required if number of pixels are calculated by initiator Table 3 62 Pixel Size Data Bit 7 6 5 4 3 1 0 Byte 0 MSB Number of X Direction Pixels 3 LSB 4 MSB Number of Y Direction Pixels 7 LSB 8 Reserved 15 LSB M 3099GX GH OEM M anual 3 83 INTERFACE Detected Paper Information DATA TYPE CODE 81h This scanner will try to detect Paper Size and Job Separation Sheet Table 3 63 Detected Paper Information Bit 7 6 5 4 3 2 1 0 Byte 0 Reserved DESSEN
61. 2 pre set mode is executed When IPC 2 pre set mode is executed in online mode the reading parameter is valid or invalid Host setting is invalid as follows M3099GX GH OEM Manual B 5 Reading parameter Reading Transfer Transfer Resolu Startof Density Line art mode mode rate tion reading Photo Valid Invalid Reading parameter DTC Size Portrait Picking Document y patterns Contrast Automatic Landscape selection separation Valid 2 2 O Invalid C C C Reading parameter Conver Oudine Overlay Simplified Zooming sion extraction DTC Valid Invalid B3 3 Reset of abrasion counter When you reset the abrasion counter you must set as follows 4 At Screen 2 press Mode 1 three times to go ETUP MODE TIEN Screen 13 Screen 13 45 Press Mode 2 to see Screen 14 You may see current paper count If you want to reset the L PESEL TEA COUNT _ 123456 M count press Mode 2 And you can see No Model 2 Screen 15 for 3 seconds Screen t If you don t want it press Mode 1 to go to Screen 13 RESET Finish 000000 When you close the setup mode go 9 Screen 15 B 6 M3099GX GH OEM Manual 3 4 Setting buzzer W hen you set the using of buzzer you must set as fol
62. 7 A2 5 How to reset the print head life counter You must reset the print head life counter when you replace the print head lt lt SETUP MODE gt gt INK RESET Screen 12 INK RESET No Mode 1 Yes Mode 2 Screen 13 RESET Finish Screen 14 3 At Screen 1 press Mode 1 eleven times to go to INK RESET screen Screen 12 4 Press Mode 2 to see Screen 13 If you want to reset the counter press Mode 2 And you can see Screen 14 for 3 sec If you don t want it press Mode 1 to go to Screen 12 If you want to close the job go to 7 A2 6 How to test the printing by the operator panel operation You can check the print result by the following procedures lt lt CE MODE gt gt TESTxx START Screen 15 5 Set the endorser ON by the procedure of the section A2 1 O While pressing the Mode 2 turn the power of the scanner on Then the LCD displays the MAINTENANCE MODE initial screen Screen 15 M 3099GX GH OEM M anual 7 Press Mode 2 once and press Mode 1 once Place the document on the stacker Then press START NOTICE The scanner prints the five digit numbers from the initial number by the increment of one NOTICE Before pressing START you can set document size resolution and so on See OPERATOR S GUIDE A3 Print head A3 1 Replacing the print head handlin 9 When INK is displayed in LCD display the operator is
63. 9GX GH OEM M anual 4 3 Table 4 1 Button functions Button name Function Start This button is used to indicate Start to scanner in TEST mode or SETUP mode at Off line This button is disabled while scanner operates in On line Stop This button is used to indicate Start to scanner in TEST mode or SETUP mode at Off line This key is used to cancel temporary error while operating at On line This key is used to lower the hopper table to the bottom during waiting for Hopper Timer This key is used to display the abrasion counter during displaying the ready screen Manual This button is used to select manual feeding mode By pressing this key setting is switched between manual feeding and ADF mode Mode 1 This button is used to start Off line SETUP mode with Power switch This button is used to select item in Off line SETUP mode Mode 2 This button is used to start Off line TEST mode with Power switch This button is used to select item in Off line SETUP mode Table 4 2 LEDs function LED Color Function Power Green When Power switch is turned on this LED is turned on Read Green While scanning this LED is turned on Check Yellow The scanner mulfunction is detected this LED is turned on When temporary error Paper Jam and so on is detected this LED is blinked Temporary error is cleared and Stop button is pressed this LED will
64. Aristote 17 rue Olof palme 94006 Creteil cedex FRANCE TEL 33 14 513 1616 FAX 33 14 399 0700 FUJITSU HONG KONG Limited Room 2521 Sum Hung Kai Centre 30 Harbour Road Wanchal Hong Kong TEL 852 827 5780 FAX 852 827 4724 TLX 62667 FUJITSU ITALIA S p A Via Melchiorre Gioia No 8 20124 Milano ITALY TEL 39 2 63651 FAX 39 2 6572257 FUJITSU NORDIC AB Kung Hans vag S 191 76 Sollentuna SWEDEN TEL 46 8 626 6000 FAX 46 8 626 6711 FUJITSU LIMITED nternational Operations Marunouchi 1 6 1 Chiyoda ku Tokyo 100 JAPAN TEL 81 3 3216 3211 FAX 81 3 3213 7174 TLX 122833 Cable FUJITSU LIMITED TOKYO M 3099GX GH OEM M anual Preface This manual provides technical information required to use the original equipment manufacturing OEM M3099G image scanner The manual is organized as shown below Chapter 1 Overview Chapter 1 provides the scanner features configuration and operation Chapter2 Specifications Chapter 2 provides general electrical environmental physical and option specifications Chapter3 Interface Specifications Chapter 3 provides SCSI interface specifications Chapter 4 Basic Operation Chapter 4 provides power switch operation opening closing the upper transport unit operator panel arrangement and functions messages loading document and replacement of parts 5 Error Processing and Recovery Chapter 5 provides how to handles temporary
65. C MB86601A VCEP OTI95C71 20 and a glue ASIC The scanned image data are transferred to interface circuit as video interface The interface circuit converts internal video interface to SCSI interface via compression if required SCSI interface transferes data 1 5MB s in Asynchronous transfer 4 0MB s in Synchronous transfer following to SCSI 2 standard The VCEP compresses the binary image data in MH MR MMR algorithm defined by CCITT G3 G4 See Chapter 3 for details of SCSI interface Resolution The basic resolution of this scanner is 200dpi The resolution can be changed to 240 300 or 400dpi from the host computer or the operator panel The resolution in the subscanning direction is achieved by changing the document transport speed When the image processing circuit II IPC II option is installed the linear density is changed by setting the parameter to its internal circuit Video amplifier and driver section This section consists of a CCD drive circuit a video amplifier circuit a white black level correction circuit sensors and also control circuits for the stepping motor heater and lamps M 3099GX GH OEM M anual 1 9 Image processing section The IPC II option enables the following image processing functions Automatic separation function to read documents containing characters and photographs nversion function Mirror image output function Outline extraction function Overlay function Sm
66. DE SENSE data The DBD bit must be in this scanner PC Page Control This field defines the type of mode parameters values to be returned in the mode pages The page control field is defined in ANSI SCSI 2 Table 55 8 2 10 1 to 8 2 10 4 005 value M 3099GX GH M anual 3 87 INTERFACE Page Code 3Dh 3Eh The page code specifies which mode page s to return Mode page code usage is defined in Table 3 68 Table 3 68 Supported Mode Page Code Page Code Description 00h Ignored Vendor specific Olh 3Eh Reserved 3Dh Lamp Timer 3Eh Job Separation Sheet 3Fh Return all mode pages An initiator may request the supported mode page from a target If an initiator issues MODE SENSE command with a page code value not implemented by the target the target shall return CHECK CONDITION status and shall set the sense key to ILLEGAL REQUEST and the additional sense code to INVALID FIELD IN CDB Mode Parameter The mode parameter list shown in Table 3 69 contains a header followed by zero or more block descriptors followed by zero or more variable length pages Table 3 69 Mode Parameter List Bit 7 6 5 4 3 2 1 0 Byte 0 n Mode Parameter Header 0 Block Descriptor s 0 n Page s Block Descriptor is optional and it is not defined for Scanner Device This scanner omitts this field The six byte command descriptor bloc
67. DOUBLE FEED CHECK Screen 5 DOUBLE FEED CHECK Screen 6 DOUBLE FEED CHECK Screen 7 4 At Screen 2 press Mode 1 once to go to the P g DOUBLE FEED CHECK screen Screen 4 5 Press Mode 2 to see Screen 5 If ON is displayed the error will be detected when the double feed is occured If OFF is displayed it wouldn t The ON or OFF status flips each time you press Mode 2 6 Press Mode 1 to see Screen 6 This means how to defect the double feed as follows 1 is the method by comparing with the length of the first paper 2 is the method by the output of Document detection sensor in addition to gt At Screen 6 press the Mode 2 until the SETUP MODE number changes as you want Press Mode 1 to see Screen 7 This means the length to compare with the paper based on If you choose 1 or 2 and set 15mm the double feed is detected when the scanned paper length is 15mm longer than the first paper At Screen 7 press the Mode 2 until the number changes as you want You can choose 10 15 or 20mm The default is 15mm M 3099GX GH OEM M anual B 3 Press Mode 1 and Mode 2 at a time to see Screen 4 The settings are stored to EEPROM 9 When you close the setup mode press Stop Then the readable screen is displayed Mode Details ON OFF OFF is default setting 1 1 is default setting Thi
68. ECK CONDITION status only when the target cannot return the requested INQUIRY data M 3099GX GH OEM M anual 3 33 If an INQUIRY command is received from an initiator with a pending unit attention condition i e before the target reports CHECK CONDITION status the target shall perform the INQUIRY command and shall not clear the unit attention condition Standard INQUIRY Data See ANSI SCSI 2 7 2 5 1 This standard INQUIRY data Table 3 12 contains 36 required bytes followed by a variable number of vendor specific parameters Bytes 56 through 95 if returned are reserved for future standardization M 3099GX GH OEM M anual Table 3 12 Standard INQUIRY Data Format Bit 7 6 5 4 3 2 1 0 Byte 0 Peripheral Qualifier Peripheral Device Type 1 Device Type Modifier n INTERFACE 2 ISO Version ECMA Version ANSI Approved Version ios 3 AENC Reserved 4 Additional Length n 4 5 Reserved 6 Reserved 7 RelAdr WBus32 WBus16 Sync Linked Reserved CmdQue SftRe 8 MSB Vendor Identification E 15 LSB 16 MSB a eene Product Identification 31 LSB 32 MSB Product Revision Level 35 LSB 36 Vendor Specific 55 56 MEER Reserved 95 Vendor Specific Parameters 96 Ire Vendor Specific n M 3099GX GH OEM M anual 3 35 The peripheral qualifier and peripheral device
69. GX GH OEM M anual Negation Period 3 13 NO OPERATION Targ 3 106 noise removing 1 10 OBJECT POSITION 3 73 Opening the Upper Transport Unit 4 2 Operation of the control unit 1 8 Operation of the mechanism unit 1 7 Operation Overview 1 7 Operator panel 1 6 1 8 4 3 Operator panel functions 4 3 Optical unit back side 1 6 Optical unit front side 1 6 Option specifications 2 6 Output density 2 1 Overlay function 1 10 Overview 1 1 Pad Replacement 4 21 Physical specifications 2 3 3 3 Pick Roller Replacement 4 18 Picking start time B 2 B 11 Picking time B 2 B 12 Power supply 1 1 10 Power supply 2 1 10 Power supply unit 1 6 1 8 Power Switch Operation 4 1 Power switch 1 6 4 1 Power On to Selection Time 3 14 Precautions 6 2 Pre pick B 2 B 7 Print density measurement 6 7 Print prohibit areas on the front and back surface 6 5 Procedure 8 2 Product ID B 2 B 10 READ Command 3 80 READ command sequencces and phase progression 3 118 Reading counter 4 6 Ream weight 6 2 RELEASE UNIT Command 3 31 Replacing the back side lamp 4 14 Replacing the front side lamp 4 11 REQUEST SENSE Command 3 49 RESELECTION 3 18 RESELECTION Phase 3 18 RESERVE UNIT Command 3 30 Reset Condition 3 25 Reset Hold Time 3 14 Reset to Selection Time 3 14 Resolution 1 9 RESTORE POINTERS Init lt Targ 3 107 Roller ASY Replacement 4 16 RS 232C interface GL 4 SAVE DATA POINTER Init lt Targ 3 107
70. ND COMPLETE In 02h O O SAVE DATA POINTER In 03h RESTORE POINTERS In 04h O O DISCONNECT In 05h M M INITIATOR DETECTED Out Yes ERROR 06h O M ABORT Out Yes 07h M M MESSAGE REJECT In Out Yes 08h M M NO OPERATION Out Yes 09h M MESSAGE PARITY ERROR Out Yes M BUS DEVICE RESET Out Yes 80h IDENTIFY In 80h IDENTIFY Out No O O SYNCHRONOUS DATA In Yes TRANSFER REQUEST others Reserved Key M Mandatory support O Optional support In Target to initiator out Initiator to target Yes Initiator shall negate ATN before last ACK of message No Initiator may or may not negate before last ACK of message see Attention Condition Not Applicable Extended message see Tables 3 84 and 3 85 80h Codes 80h through FFh are used for IDENTIFY messages See Table 3 86 3 100 M 3099GX GH OEM M anual A value of one in the first byte of a message indicates the beginning of a multiple byte extended message The minimum number of bytes sent for an extended message is three The extended message format and the extended message code are shown in Table 3 84 and 3 85 respectively Table 3 84 Extended Message Format Bit 7 6 5 4 3 2 1 0 Byte 0 Extended message 01h 1 Extended message length n 2 Extended message code y 3 Extended message arguments 1
71. ODE This chapter explains the setup mode of the scanner B l Activating When you activate the setup mode you must set as follows the setup mode D While pressing the Mode 1 turn on the le b E power of the scanner Then the LCD Warming up Now displays Screen 1 Screen 1 2 After a while the LCD displays the SETUP MODE initial screen Screen 2 lt lt SETUP MODE gt gt posee 3 Press the Mode 1 to go to the SETUP MODE menu screen Press the Stop to go Screen 2 to the readable status Screen 3 Scanner Ready POWER ON B 2 Operational transition in the setup LUE NE 1 ne RE Setup p mode E Warm up gt When Model button is pressed at power on D Press the Model button NT 2 The device goes online M 3099GX GH OEM M anual B 1 B 3 Contents of The setup mode can be classified into eighteen the setup Mode Setup type Contents mode 1 Setting double feed Set in EEPROM whether double feed detection detection is done or not 2 Setting IPC 2 Set in EEPROM the pattern No of IPC 2 pre pre set set mode 3 Resetofabrasion Reset the abrasion counter after Belt Roller are counter exchanged 4 Setting buzzer Set in EEPROM whethr the buzzer function is on or off 5 Setting pre pick Set in EEPROM whether pre picking is done for fast reading or not 6 Adjusting LCD Set in EEPROM the LCD
72. OPERATION Close the upper transport unit See page 4 2 M 3099GX GH OEM M anual 4 13 Replacing back side lamp Turn off the power switch 2 Slide and open the side cover small cover on the center of the right cover Side cover Power switch 3 Turn the thumb screw to unlock the lamp unit and pull the unit out of the machine Thumb screw Lamp unit 4 Rotate the lamp so that the two terminals on each end Lamp align with the exit slot on the lamp socket Maintain the alignment and remove the lamp from the lamp sockets CAUTION Be careful not to pull the wire Lamp unit of the heater hard 4 14 M 3099GX GH OEM M anual 5 Separate the C shaped heater from the lamp body gently CAUTION Be careful not to peel the tape on the heater If any visible damage on the heater is observed please contact manufacturer s authorized service center for proper repair service BASIC OPERATION 6 Re attach a new lamp to the C shaped heater Note Position the lamp so that the following lengths are the same al a2 Heater bee be Window Cross sectional view of lamp and heater M 3099GX GH OEM M anual 4 15 7 To reinstall lamp heater Window cO reverse procedures in item 4 N ote M ake sureto rotate lamp in the direction as shown in the left figure Socket Align the lamp unit with the grooves on the machine and in
73. ORSER option is used 4 8 M 3099GX GH OEM Manual Loading This section provides how to load documents Document When the LCD display on operator panel has displayed Hopper Empty supply documents as follows D Set the specified document width Hold the lock lever at the guide center on the right of the hopper table and move it horizontal to set the document width BASIC OPERATION 2 Load document read side face up on the hopper table Note 1 Be sure not to load documents higher than the line marked inside the guide on each side of the hopper table Line mark 2 If the documents are too long pull out the extension at the front of the hopper Document i Extension Hopper table M 3099GX GH OEM M anual 4 9 Stacker 3 Adjust the stacker table to the document size Stacker table ote Extend the stacker table and extension for long documents Stand and extend the stopper up and also turn the lever in the stacker down for short Document documents If the scanner is 500 sheets hopper type extend the stacker table for long 305 documents And also use n stopper for small documents Load a document about 20 mm a part from the stopper Stopper Lamp The scanner has two lamps one for front side reading and other for Replacement back side reading Replace the lamps as follows WARNING Never replace lamp without turning off the power
74. RECOVERY 5 6 M 3099GX GH M anual CHAPTER DOCUMENT SPECIFICATION This chapter provides document specification size type limitations grounding color area drop out color and job separation sheet for the scanner Document Size Figure 6 1 shows document sizes which the scanner can read For M3099GH however maximum size of A3 can be fed through the scanner Feeding direction a Y Unit mm M aximum Minimum Scanner M 3099GH 216 356 76 63 M 3099GX 297 432 76 63 Figure 6 1 Document size M 3099GX GH OEM M anual 6 1 DOCUMENT SPECIFICATION Document This section provides document types and weights available for the Quality scanner with precautions Document type The recommended paper type for document is as follows NOTICE Use specified paper only In rare occasion double feeding may occur or document damage may occur Fine paper Plain paper For example the paper specified for XEROX 4024 OCR paper When using all other type paper check that it is successfully fed by ADF before performing a reading operation Ream weight The ream weight is as follows 45 to 110 kg 13 9 to 34 Ib 52 to 127 g m Note Ream weight is a weight of 1000 sheets of paper whose size is 788 mm x 1091 mm Precautions Be careful to scan the following documents Preliminary document feed test may be necessary to avoid the unexpected
75. SCAN Command 3 79 Scanning method 2 1 Scanning Sequence 3 115 Scanning speed 2 1 SCSI Bus 3 7 SCSI Bus Conditions 3 24 SCSI Bus Phases 3 15 SCSI Bus Phases Sequences 3 26 SCSI ID B 2 B 10 Selection Abort Time 3 14 SELECTION Phase 3 17 Selection Time out Delay 3 14 M 3099GX GH OEM M anual IN 3 SEND COMMAND 3 74 SEND DIAGNOSTIC Command 3 55 Sensor 2 1 SEPARATION PRESSURE ADJUSTMENT C 1 SET WINDOW Command 3 56 Shape 6 8 Signals 3 8 Signal Source 3 9 Signal Values 3 9 Smoothing 1 10 SPECIFICATIONS 2 1 Stacker 1 6 Standard INQUIRY Data 3 34 Status 3 97 STATUS Phase 3 23 Superseding Reservations 3 31 Synchronous Data Transfer 3 21 SYNCHRONOUS DATA TRANSFER REQUEST 3 107 System Initialization 3 110 TEST UNIT READY Command 3 32 Timing 3 11 Time out limit B 2 B 12 Transfer Period 3 15 Vendor Unique Parameters 3 65 Verify State Test 3 112 Video circuit front side back side 1 8 Vital Product Data 3 37 IN 4 M 3099GX GH OEM M anual Reader Comment Form We would appreciate your comments and suggestions for improving this publication Publication No Rev Letter Title Current Date Learning Reference Installing How did you use this publication Sales Maintaining Operating Is the material presented effectively Fully Well Covered illustrated Well Organized L Good
76. ST screen Screen 20 64 Press ode 2 to see Screen 21 The number of is increased and the CD contrast is getting darker 5 At Screen 21 the contrast is set in 16 Screen 21 steps each time you press M ode 1 When all fields are filled by Ml next pressing M ode 1 stars from all 1 The lightest contrast 26 Press ode 2 to see Screen 20 T he settings are stored to EEPROM Q7 When you close the setup mode go to 9 B3 7 Setting pick speed When you set the pick speed you must set as follows lt lt SETUP MODE gt gt PICK SPEED SET Screen 22 PICK SPEED SET Screen 23 08 At Screen 2 press M ode 1 seven times to go to the PICK SPEED SET screen Screen 22 69 Press M ode 2 to see Screen 23 T he default setting is FAST If FAST is displayed the pick speed is fast If SLOW is displayed the pick speed is sow The FAST SLOW status flips each time you press M ode 1 Thestatus will beset in EEPROM automatically 60 If you want to return to Screen 22 press M ode 2 W hen you close the setup mode go to 9 M 3099GX GH M anual B3 8 Setting initial value of endorser When you set the using of endorser and the initial number you must see Section A2 1 and A2 2 of Appendix A The details are as follows The using of Endorser ON OFF The de
77. T SENSE 03 Requests the target transfer sense data to the initiator SEND DIAGNOSTIC 1D Request the target to perform diagnostic operations on itself ENDORSER Ci Start Stop endorser function TEST UNIT READY 100 Check if the logical unit is ready SET WINDOW 24 Specify windows within the scanning range of the device SEND 2A Transfers data from initiator to target OBJECT POSITION 131 Provids positioning functions ADF Feed in out SCAN 18 Requests the target begin a scan operation READ 28 Requests the target transfer data to the initiator MODE SELECT 6 15 Specify logical unit peripheral device parameters from the initiator to the target MODE SENSE 6 Report parameters from the target to the initiatot M 3099GX GH OEM M anual 3 29 INTERFACE RESERVE UNIT Command The RESERVE UNIT command Table 3 8 is used to reserve logical unit for the exclusive use of the requesting initiator to another specified SCSI device Table 3 8 RESERVE UNIT Command Bit 7 6 5 4 3 2 1 0 Byte 0 Operation Code 16h Logical Unit Number 3rdPty Third Party Device ID Reserved Reserved 1 2 3 Reserved 4 5 Reserved Control The RESERVE UNIT and RELEASE UNIT commands provide the basic mechanism for contention resolution in multiple initiator systems This command requests that the entire logical unit be reserved for the exclusive use of the initiat
78. TERS SAVE DATA POINTER e SYNCHRONOUS DATA TRANSFER REQUEST Physical Connection INTERFACE Specifications SCSI devices are daisy chaned together using a common 50 conductor A cable and optionally a 68 conductor B cable Both ends of each cable are terminated signals are common between all SCSI devices on the cable In systems that employ the wide SCSI option wide SCSI devices additionally connect to the cable Various width SCSI devices may be mixed This scanner supports A cable Note Use of B cable is not recommended because of ANSI draft proposal indicates this definition is removed in a future version of the SCSI SCSI device SCSI device SCSI device SCSI device I TT TERM INATOR 7 UL UT TERMINATOR Figure 3 1 SCSI device connection M 3099GX GH OEM M anual 3 3 Physical specification Table 3 1 SCSI physical specification Item Specification Driver receiver Single Ended Connector 50 Contact Shielded Low Density Cable cable length 6m Characteristic impedance 90 Q to 1400 Cable type 25 signal twisted pair Stub length 0 1 m from mainline Signal Terminator See Figure 3 2 level Driver receiver Open collector or three states driver Output characteristics Low level output voltage High level output voltage 0 0 to 0 5 volts dc at 48
79. a Halftone Mask Table 3 57 Halftone Mask Bit 7 6 5 4 3 2 1 Byte 0 Reserved pe nee 222 4 MSB X direction Halftone Mask Size BN LSB 6 MSB Y direction Halftone Mask Size x LSB 8 Reserved 9 Reserved 10 Halftone Mask Data X direction Halftone Mask Size 8 This field specifies halftone mask size in x direction Y direction Halftone Mask Size 8 This field specifies halftone mask size in y direction X and Y direction halftone mask must be equal size 3 76 M 3099GX GH OEM M anual Halftone Mask Data The Halftone Mask Data specifies halftone mask to be transferred to target The byte data order is left to right upper to lower nature Halftone Mask is a series of threshold values applied to grayscale image data 0 is the lowest and 255 is the highest Example 8x8 halftone mask X D00 D00 D02 D03 D04 D05 D06 D07 D10 D11 D12 D13 D14 D15 D16 D17 D20 D21 D22 D23 D24 D25 D26 D27 Y D30 D31 D32 D33 D34 D35 D36 D37 D40 D41 D42 D43 D44 D45 D46 D47 D50 D51 D52 D53 D54 D55 D56 D57 D60 D61 D62 D63 D64 D65 D66 D67 D70 D71 D72 D73 D74 D75 D76 D77 Transfer Order and Data ORDER 0 1 2 3 4 5 6 7 8 9 10 DATA 00h 00h 00h 00h 00h 00h 00h 00h 00h 00h 00h 11 12 13 14 15
80. a 0 0 1 DATAIN Initiator from target Phase 0 1 0 Initiator to target 0 1 1 STATUS Initiator from target 1 0 0 1 0 1 m 1 1 0 MESSAGE OUT to target Message 1 1 1 IN Initiator to target Phase Key 0 False 1 True Reserved for future standardization Asynchronous Information Transfer The target shall control the direction of information transfer by means of the I O signal When the I O signal is true information shall be transferred from the target to the initiator When the I O signal is false information shall be transferred from the initiator to the target If the I O signal is true transfer to the initiator the target shall first drive the DB 7 0 P signals to their desired values delay at least one deskew delay plus a cable skew delay then assert the REQ signal The DB 7 0 P signals shall remain valid until the signal is true at the target The initiator shall read the DB 7 0 P signals after the REQ signal is true then indicate its acceptance of the data by asserting the ACK signal When the ACK signal becomes true at the target the target may change or release the DB 7 0 P signals and shall negate the REQ signal After the REQ signal is false the initiator shall then negate the ACK signal After the signal is false the target may continue the transfer by dividing the DB 7 0 P signals and asserting the REQ signal as described above
81. able 3 41 Compression Types and Arguments Compression Description Compression Code Argument 00h No Compression Reserved 01h CCITT Group 1 dimensional Reserved 02h CCITT Group IIL 2 dimensional K factor 03h CCITT Group IV 2 dimensional Reserved 04h to FFh Reserved Reserved Note factor can be specified from 0 to 255 0 indicates K factor 3 64 M 3099GX GH OEM M anual Vendor Unique Parameters After byte 40 of Set Window Data is defined as Vendor Specific Parameter Fujitsu Image Scanners define this area for additional informations of window The type of paramters are distinguished by Vendor Unique Identification Code value This scanner supports additional 24 bytes length Image Processing Parameter Vendor INTERFACE Unique Identification Code 00h Image Processing Parameter Table 3 42 Table 3 42 Image Processing Parameter Bit 7 6 5 4 3 2 1 0 Byte 40 Vendor Unique Identification Code 41 Gamma Correction 42 Outline Extract 43 Image Emphasis 44 Automatic Separation 45 Mirroring 46 SDTC parameter 47 DTC mode 48 1 49 50 White Level Follower mode 51 Barcode Window List 52 Subwindow List 53 Paper Size 54 MSB Paper Width X 57 158 58 1 5 Paper Length Y 6l LSB 62 DTC selection 63 Reserved M 3099GX GH OEM M anua
82. amma Correction Table Gamma Correction Table Data The gamma correction table data transfers look up table for image data to be scanned Example 256 steps of grayscale INPUT 0 1 2 3 4 6 7 8 9 OUTPUT 00h 00h 00h 00h 00h 00h 00h 00h 00h 00h ORDER 10 11 12 13 14 15 16 17 263 264 265 DATA DO DO DO DO DO DO DO D253 D254 D255 DO to D255 can be any 0 to 255 value Each data is one byte length Endorser Data See ENDORSER Command SCAN Command The SCAN command Table 3 59 requests the target begin a scan operation Table 3 59 SCAN Command Bit 7 6 5 4 3 2 1 0 Byte 0 Operation Code 1Bh 1 Logical Unit Number Reserved 2 Reserved 3 Reserved 4 Transfer Length 5 Control M 3099GX GH OEM M anual 3 79 INTERFACE The transfer length specifies the length in bytes of the window identifier list that shall be sent during the DATA OUT phase A transfer length of zero indicates that no data shall be transferred This condition shall not be considered as an error The window identifier list consists of zero or more window identifiers each of which specifies a window to be scanned This command is mandatory when scanning in duplex mode by sending window identifier 00h 80h When scanning in simplex mode this command
83. anner For detail information refer to ANSI SCSI standard document Definitions SCSI device A host adapter or a target controller that can be attached to the SCSI bus Initiator An SCSI device that requests an I O process to be performed by another SCSI device a target Target An SCSI device that performes an operation requested by an initiator e Logical unit A physical or virtual peripheral device addressable through a target Scope This interface specification is following X3T9 2 draft proposal revision 10 refering JBMS Japan Business Machine Standard System configuration This scanner operates under the multi initiator multi target environment An initiator function is not provided This scanner incorporates an integrated target and logical unit image scanner SCSI ID 0 to 7 changeable default 5 Logical Unit Number LUN 000b fixed 3099GX GH OEM M anual 3 1 Bus phases phases are supported Commands INQUIRY OBJECT POSITION MODE SELECT 6 MODE SENSE 6 READ RELEASE UNIT REQUEST SENSE RESERVE UNIT SCAN SEND SEND DIAGNOSTIC SET WINDOW TEST UNIT READY ENDORSER ENDORSER option is required Statuses BUSY CHECK CONDITION GOOD RESERVEATION CONFLICT Messages ABORT BUS DEVICE RESET COMMAND COMPLETE DISCONNECT IDENTIFY INITIATOR DETECTED ERROR MESSAGE PARITY ERROR MESSAGE REJECT 3 2 M 3099GX GH OEM M anual NO OPERATION RESTORE POIN
84. anual 1 1 Table 1 2 Types of M3099GX Type 1000 sheets hopper with IPC2 Item 100V 200V a A3 Double letter document size Scanning Simplex 60 PPM A4 200dpi portate Duplex 50 PPM A4 200dpi portrate Hopper capacity 1000 sheets 530 mm IPC2 option Installed Input voltage 100V 200V Appearance Figure 1 2 Figure 1 1 500 sheets hopper type 1 2 M 3099GX GH OEM M anual Figure 1 2 1000 sheets hopper type M 3099GX GH M anual 1 3 Features This scanner has the following features Duplex reading Both sides of a document are read at the same time and their data transferred serially Fast reading This scanner can read documents at high speed 80 sheets min A4 200dpi in the simplex reading mode and 60 sheets min A4 200dpi in the duplex reading mode by M3099GH Large capacity hopper Up to 1000 sheets A4 55 kg can be loaded on the hopper by the 1000 sheets hopper type High quality image This scanner uses a compact optical system that provides sharper focus Furthermore the use of new LSI chips produces finer images New image processing function The error diffusion feature is provided as standard Dithering or error diffusion can be applied to those areas judged to be photographs by automatic separation image processing II option 1 4 M 3099GX GH OEM M anual Configuration This section provide
85. aps or thin barely connected lines due to even optical density Filtering detects areas lighter than their surroundings and increases their density to improve image clarity Hexadecimal base 16 numbering system also commonly referred to as hex numbers Since a base 16 system requires 16 digits numbers 0 through 9 and letters A through F are used It is convenient to express binary numbers in hexadecimal because fewer digits are required GL 2 M 3099GX GH OEM M anual Image emphasis Density is decreased for lighter but not completely white areas adjacent to black areas Weakening this emphasis eliminates spot noise or produces softened images Interface The connection that allows communication from one part of a system to another For example electrical signals are transferred between the computer and scanner over an interface cable Inversion Reverse image reading In reverse image reading data is changed from black to white and vice versa IPC Il Image processing option of this scanner Letter size A standard paper size used in the U S A and other countries Paper is 8 1 2 x 11 inches 215 9 x 279 4 mm Manual mode A mode that the operator can put the document on the hopper one by one A document on the hopper can be read automatically Manual start mode A mode that the scanner starts to read by pressing the START button on the operator panel 1 1 GLOSSARY OF Mirror image TEE The
86. at eere 3 41 3 17 Physical DUiCEOB n rr RR ou E 3 42 3 18 Implemented Standard Command 3 43 rS Br r iR 3 44 3 20 Implemented Vendor Specific Command 3 44 3 21 Implemented Vendor Specific Command 3 44 3 22 Vendor algae D AXE 3 45 2 23 Image 3 47 3 24 Image Processing Function 3 47 3 253 FUNCION 3 48 3 26 Endorser 3 48 3 27 REQUEST SENSE Command 3 49 3 28 Sense Data Format 3 50 M 3099GX GH OEM M anual 3 29 Sense Rey Descriptions aeternae terere 3 52 3 30 Implementation of SK Sense Key ASC Additional Sense Code ASCQ Additional Sense Code Qualifier Hierachy 3 54 SEND DIAGNOSTIC Command 3 55 334 SET WINDOW Command nita 3 56 3 33 Set Window Data Header 3 57 3 34 Window descriptor 3 58 MI NR QR 3 61 3 61 337 CONTASE S 3 62 3 38 Image Composition Codes rp Pap pta EE EPNeRE 3 62 2 29 Halftone 3 63 2 50 Halftone 3 63 3 41 Compression Types and Arguments sicsictiisiisascssiasensatentonccs 3 64 3 42 Image Processing Parameter 3 65 3 43 Gamma Cor
87. be driven by the initiator target or both as specified in the SELECTION phase and RESELECTION phase If driven this signal shall be driven only by the active initiator The signal shall be released that is not be driven by any SCSI device The bias circuitry of the bus terminators pulls the signal to the false state The signal shall be driven by the one SCSI device that wins arbitration If the signal is driven it shall be driven only by the active target M 3099GX GH OEM M anual SCSI Bus Timing Unless otherwise indicated the delay time measurements for each SCSI device shown in Table 3 5 shall be calculated from signal conditions existing at that SCSI device s own SCSI bus connection Thus these measurements except cable skew delay can be made without considering delays in the cable The timing characteristics of each signal are described in the following paragraphs Table 3 5 SCSI Bus Timing Values Timing Description Timing Values Arbitration Delay 2 4 us Assertion Period 90 ns Bus Clear Delay 800 ns Bus Free Delay 800 ns Bus Set Delay 1 8 us Bus Settle Delay 400 ns Cable Skew Delay 10 ns Data Release Delay 400 ns Deskew Delay 45 ns Disconnection Delay 200 us Hold Time 45 ns Negation Period 90 ns Power On to Selection Time 10 s recommended Reset to Selection Time 25 Us Reset Hold Time 200 us Selection Abort Time 200 us Selection Time out Dela
88. be turned off 4 4 M 3099GX GH OEM M anual LCD display When the Power switch is turned on following messages are displayed on LCD at On line Power On to Ready 0123 45 67 8 9 10 11 12 13 14 15 17 18 19 20 21 22 23 Operation Ready 0123 45 67 8 9 10 11 12 13 14 15 17 18 19 20 21 22 23 Re Operation Ready in Manual Feed mode 0123456 7 8 9 101112 13 14 15 17 18 19 20 21 22 23 M c a a Warning 0123456 7 101112 13 14 15 17 18 19 20 21 22 23 N K PTY The lower line is blinking and displays the ink empty of print head after the scanning operation This warning display will be reset when the covers are opened or STOP is pressed or Start command is issued The operator must change the print head and reset the ink counter M 3099GX GH OEM M anual 4 5 BASIC OPERATION Paper Counter 012 3 45 67 8 9 1011 12 13 14 15 16 17 18 19 20 21 22 23
89. by a target on the A cable to indicate request for an information transfer handshake ACK signal driven by an initiator on the A cable to ACKNOWLEDGE indicate an acknowledgement for a REQ information transfer handshake ATN ATTENTION signal driven by an initiator to indicate the ATTENTION condition RST RESET An OR tied signal that indicates the RESET condition DB 7 0 P Eight data bit signals plus a parity bit signal that DATA BUS from a DATA BUS DB 7 is most significant bit and has the highest priority during the ATTENTION phase Bit number significance and priority decrese downward to DB 0 A data bit is defined as one when the signal value is true and is defined as zero when the signal value is false Data parity DB P shall be odd Parity is undefined during the ARBITRATION phase 3 8 M 3099GX GH OEM M anual Signal Values Signals may assure true or false values These are two methods of driving these signals In both cases the signal shall be actively driven true or asserted In the case of OR tied drivers the driver does not drive the signal to the false state rather the bias circuitry of the bus terminators pulls the signal false whenever it is released by the drivers at every SCSI device If any driver is asserted then the signal is true In the case of non OR tied drivers the signal may be actively driven false In this standard whenever the term negated is used
90. contrast contrast 7 Setting pick speed Set in EEPROM whether pick speed is fast slow 8 Setting initial value Set the using of endorser and the initial of endorser number The set value is able to be stored in number EEPROM 9 Setting method of Set in EEPROM whether the number is reset endorser reset by hopper empty detection 10 Reset of endorser Reset the number to initial value number 11 Reset of ink Reset the ink counter after the print head has counter be replaced 12 Setting SCSI ID Set the SCSI ID 0 7 13 Setting Product ID Set the Product ID M3096G M3099G M3099GH 14 Setting picking Set in EEPROM the time from when the start time hopper empty sensor is blocked in manual mode until picking begins 15 Setting picking Set the time from when picking begins until the time SF1 sensor is blocked by paper 16 Setting time out Set the time from when a command is issued in limit manual mode until paper is actually detected B 2 M 3099GX GH OEM M anual Mode Setup type Contents 17 Setting hopper time Set the time from when Start Command Timeout limits until hopper table is lowered 18 Setting heater control Set in EEPROM whether the heater control is on or off B3 1 Setting double feed detection When you set the using of double feed detection you must set as follows lt lt SETUP MODE gt gt DOUBLE FEED CHECK Screen 4
91. cturer and model for each available logical unit this information may not be available for SCSI 1 devices 5 wa The critical device type information for each available logical unit 6 7 This information varies depending device type Extended functionality of SCSI devices such as target role capability in 8 devices that are principally initiators AEN capability etc The following states are established for each attached logical unit that has power available and is not failing 1 The ready state for each available logical unit including any required medium initialization but not initialization but not formatting 2 All error conditions associated with the starting process are cleared 3 All UNIT ATTENTION conditions are cleared 4 All data transfer parameters are established 3 110 M 3099GX GH OEM M anual 5 pertinent system tuning parameters are established where known Note that these may be modified dynamically to improve the performance characteristics of the system The following procedures show the sequences necessary to implement a system that initializes itself with a minimum of information available at power on time Many real systems not generalized having considerable information available about the proper configuration at power on time In those cases sequence steps that would have been necessary to obtain that predefin
92. des are defined in READ command For the Data Type Code 02h Halftone Mask this field indicates INTERFACE Halftone Mask identifier Available identifier number is depends on numbers of downloadable halftone masks If higher identifier is specified CHECK CONDITION status is returned and Sense Key is set to ILLEGAL REQUEST This scanner supports 8 Halftone Masks Halftone Mask identifier 0 to 7 are available For the Data Type Code 03h Gamma Function this field indicates Gamma Function Table identifier Available identifier number is depends on numbers of downloadable Gamma Function Table If higher identifier is specified CHECK CONDITION status is returned and Sense Key is set to ILLEGAL REQUEST For the other Data Type Code this field is reserved The transfer length specifies the number of blocks the target shall transfer from the initiator during the DATA OUT phase This scanner block size is defined as one byte by following JBMS A transfer length of zero is not considered an error and no data shall be transferred If longer acceptable data length is specified in transfer length CHECK CONDITION status is returned and ILLEGAL REQUEST is set to Sense Key Maximum Transfer Length of this scanner is 1034 bytes This command shall be terminated with a status of RESERVATION CONFLICT if any reservation access conflict see ANSI SCSI 2 10 2 10 exists and no data shall be transferred M 3099GX GH OEM M anual 3 75 SEND Dat
93. dor Unique Parameter pages defined in SET WINDOW command Vendor Unique Parameter field consists of 16 sets of 2 bytes structure as Table 3 22 Vendor Unique Parameter field are subdivided to fields to FXh INTERFACE Table 3 22 Vendor Unique Parameter Bytes Description Value 50 51 Vendor Unique Parameter 0001h 52 53 Vendor Unique Parameter 1Xh 0000h 54 55 Vendor Unique Parameter 2Xh 0000h 56 57 Vendor Unique Parameter 3Xh 0000h 58 59 Vendor Unique Parameter 4Xh 0000h 60 61 Vendor Unique Parameter 5Xh 0000h 62 63 Vendor Unique Parameter 6Xh 0000h 64 65 Vendor Unique Parameter 7Xh 0000h 66 67 Vendor Unique Parameter 8Xh 0000h 68 69 Vendor Unique Parameter 9Xh 0000h 70 71 Vendor Unique Parameter AXh 0000h 72 73 Vendor Unique Parameter BXh 0000h 74 75 Vendor Unique Parameter CXh 0000h 76 77 Vendor Unique Parameter DXh 0000h 78 79 Vendor Unique Parameter EXh 0000h 80 81 Vendor Unique Parameter FXh 0000h Image Control Function field indicates supplementary information on SET WINDOW arameter Image Control Function field is subdivided to Brightness Steps Threshold Steps Contrast Steps Number of resident Dither Number of registrable Dither Number of resident Gamma Function Number of registrable Gamma Function as Table 3 23 M 3099GX GH OEM M anual 3 45 Brightness Step FFh 255 steps Brightness Step field
94. e 17h Logical Unit Number 3rdPty Third Party Device ID Reserved Reserved Reserved Reserved 1 2 3 4 5 Control The RESERVE UNIT and RELEASE UNIT commands provide the basic mechanism for contention resolution in multiple initiator systems If a valid reservation exists for the I L nexus the target shall release the reservation and return GOOD status M 3099GX GH OEM M anual 3 31 INTERFACE reservation may only be released by the initiator that made it It is not an error to attempt to release reservation that is currently valid or is held by another initiator In this case the target shall return GOOD status without altering any other reservation 3rdPty Ob Reserved Third Party Device ID 000b Reserved TEST UNIT READY Command The TEST UNIT READY command Table 3 10 provides a means to check if the logical unit is ready This is not a request for a selftest If the logical unit would accept an appropriate command without returning CHECK CONDITION status this command shall return a GOOD status If the logical unit cannot become operational the target shall return CHECK CONDITION status with a sense key of NOT READY Table 3 10 TEST UNIT READY Command Bit 7 6 5 4 3 2 1 0 Byte 0 Operation Code 00h 1 Logical Unit Number Reserved 2 Reserved 3 Reserved 4 Reserved 5 Control INQUIRY Co
95. e DATA BUS DB 7 is the highest then the SCSI devices has lost the arbitration and the SCSI device may release its signals and return to Step a If no higher priority SCSI ID bit is true on the DATA BUS then the SCSI device has won the arbitration INTERFACE and it shall assert the SEL signal Any SCSI device other than the winner has lost the arbitration and shall release the BSY signal and its SCSI ID bit within a bus clear delay after the SEL signal becomes true An SCSI device that loses arbitration may return to Step a The SCSI device that wins arbitration shall wait at least a bus clear delay plus a bus settle delay after asserting the SEL signal before changing any signals e SELECTION Phase The SELECTION phase allows an initiator to select a target for the purpose of initiating some target function e g READ or WRITE command During the SELECTION phase the I O signal is negated so that this phase can be distinguished from the RESELECTION phase The SCSI device that won the arbitration has both the BSY and SEL signals asserted and has delayed at least a bus clear delay plus a bus settle delay before ending the ARBITRATION phase The SCSI device that won the arbitration becomes an initator by not asserting the I O signal The initiator shall set the DATA BUS to a value which is the OR of its SCSI ID bit and the target s SCSI ID bit and it shall assert the ATN signal indicating that a MESSAGE OUT phase is to follow
96. e condition below More than More than Less than 30mm Feeddirection ess than 20mm Feed direction 3mm 5mm NC N x Ty Read surface Top of the paper Read siirf ce Top of the paper Document This section provides restrictions on document used for the scanner Limitations Areas that must not be perforated Perforations are prohibited in the shaded area of Figure 6 2 to avoid document size detection error or job separation sheet detection error or jam Reading reference osition poson a 134 T 96 f Unit mm 10 10 ko I m ul Docurrert feeding direction Front side Reading surface Top of document Bottom of document 10 k 10 Center of document Figure 6 2 Areas that must not be perforated 6 4 M 3099GX GH OEM M anual Print prohibit areas on the front and back surfaces Printing in area on the front of a document may in rare case cause a document size detection error Printing in area B on the front and back of a document may in rare case result a double feed error Figure 6 3 shows print prohibit areas on the front and back surfaces Note Figure 6 3 shows the document as viewed from the reading surface 113 134 Reading Unit mm reference z 79 96 i position i Top of document DOCUMENT x i 0 9 Area 5 Area B
97. e lamp make sure to rotate the lamp in the direction as shown in the left figure 7 Close the upper transport unit See page 3 5 8 4 M 3099GX GH OEM M anual Cleaning the rollers Cleaning the rollers with Cleaning Sheet 1 Se the hopper table guides to the B4 width Guide 2 Remove protective paper from the cleaning sheet With the adhesive side up place the cleaning sheet on the hopper table by aligning it with the left guide 3 Press M OD E2 twice Lock M ODE1 once then lever ST ART T he hopper table goes up and the cleaning sheet is transported 4 By aligning with the right Hopper table guide place the same CRANE cleaning sheet on the Right hopper table with the guide adhesive side up ee 5 Hopper table d Ban 5 Transport the cleaning Sheet by the switch operations of 3 6 Place a new cleaning sheet on the hopper table with Left guide the adhesive side down and EROHT repeat steps 2 to 5 M 3099GX GH OEM M anual 8 5 Cleaning the rollers with dry cloth and alcohol Cleaner This roller exists only 1000 sheets D O pen the upper transport hopper type unit See page 4 2 Upper transport unit 2 Wipe the pick rollers belt and the upper and lower transport unit rollers with a dry cloth or cloth soaked in isopropyl alcohol Pick rollers 3 Close the upper transport unit See page 4 2 Belt Lower transpor
98. e list of available logical units Each available logical unit should be added to the host configuration information identifying the associated logical unit number device type manufacturer and model Verify State The verify state test should be made to clear any outstanding errors capture and clear UNIT ATTENTION conditions and determine the state of readiness of the available logical units The logical units should be identified as ready not ready or failing by this test Device Initialization The device undergoes a device dependent initialization process This process is described for direct access devices sequential access devices and processor devices Other device initialization procedures are not described since they tend to be similar to one of these initialization procedures The initialization process takes into account the state of the device as identified during the verify state test Device On line The successful completion of the device initialization process allows the device table entry to be fully enabled The device joins the system with all key parameters identified and initialized The device state is known and may be presented to the system operator Verify State Test The verify state test uses the following steps to identify any outstanding errors clear any UNIT ATTENTION conditions and determine the readiness of the devices The verify state test should be executed against each available logical unit
99. ed information may be skipped or ignored General Procedure for Initializing Devices Initiator Activities Power On It is assumed that each SCSI device as it is powered on performs appropriate internal reset operations and internal test operations Once powered on initiators that have target capability should be prepared to respond to a selection within a system specific time Reset At power on time it is likely that an SCSI device has caused errors to the ongoing activities on the SCSI bus A bus reset should be generated to notify attached devices that any activities that may have been occurring should be restarted Find Device Each SCSI address other than the initiator s SCSI address should be tested to determine if an SCSI device responds If an SCSI device responds an INQUIRY command to logical unit 0 should be executed The information obtained indicates the device type manufacturer and model of the attached logical unit 0 if the response data format field is one or two If the response data format field is zero only the device type field is valid In addition the version of command set supported by the device is indicated by the ANSI approved version field M 3099GX GH OEM M anual 3 111 Find logical units Each possible logical unit number on the attached targets should be tested for experience using an INQUIRY command Those found with a non zero peripheral qualifier in the INQUIRY data should not be included in th
100. ed for system which scans one page document dividing small quantity of data reading and saving to storage TD 0 ARB Init SEL Init Targ MO IDENTIFY CMD READ TL M 0 ARB arg RESEL Targ lt Init MO DENTIFY mage Data 64KB N M 464KB N MI SAVE DATA POINTER MI DISCONNECT BF ARB arg RESEL Targ lt Init MO DENTIFY DI mage Data TL M TD4 TL Yes TD gt WD No EOM 1 SS No STS CHECK CONDITION STS GOOD MI COMMAND COM PLETE MI COMMAND COMPLETE BF BF V Read End See Note 1 2 3 120 M 3099GX GH OEM M anual Notes 1 Ifthe requested Transfer Length does not equal to actually transferred data size the scanner returns CHECK CONDITION status and create Sense Data as bellow ILI 1 INFORMATION TL requested Transfer Length actual transferred data size INTERFACE This status is sent to the latest READ command For the other READ commands the GOOD status will be returned If requested Transfer Length in last READ command equal to the data size that should be transferred CHECK CONDITION status will be returned to next READ command 2 In addition to Note 1 when completion of image data transfer the scanner sets EOM bit to 1 If initiator issues REQUEST SENSE command for each READ command Sense Key
101. entifier Strictly speaking SCAN command is used to specify Window Identifier but we used this field SCAN command can be omitted from scanning sequence For the other data type code data type qualifier field is reserved M 3099GX GH OEM M anual 3 61 The transfer length specifies the number of blocks the target shall transfer to the initiator during the DATA IN phase The block size is 1 byte in fujitsu scanner transfer length of zero is not considered an error and no data shall be transferred If the target transfers less than transfer length blocks CHECK CONDITION status shall be returned The ILI bit is set to one the valid bit is set to one and the information bytes are set to the difference residue between the requested transfer length and the actual number of blocks transferred The command shall be terminated with a status of RESERVATION CONFLICT if any reservation access conflict see ANSI SCSI 2 10 2 10 exists and no data shall be transferred Data Type Format Image Data DATA TYPE CODE 00h Pixel Coordinates in a document Top X direction 0 0 1 0 2 0 iets x 2 0 x 1 0 0 1 1 1 2 1 2 1 1 1 0 2 1 2 2 2 m x22 x12 Left ED 0 Right Y Direction l 0 2 1 2 2 2 x 2 y 2 1 2 0 y 1 Ly l Zy l x 2 y 1 x Ly 1 Bottom Bit Order in a Byte of Binary Data X dir 0 1
102. equal one byte Dither GLOSSARY OF Technique for producing halftone images representing the entire TERMS grayscale using two pixel levels black and white dpi Dots per inch M 3099GX GH OEM M anual GL 1 Endorser The unit for printing characters before or after scanning These characters may be used for collation of the documents and the image data See appendix A Equipment error An error which the operator can not recover such as optical system alarm temperature alarm and so on It is necessary to make contact manufacturer s authorized service center for paper repair service Error diffusion High quality halftone pseudo grayscale image production base on black and white pixel binarization A pixel s optical density and that of adjacent pixels are summed with black pixels relocated in their order of density as they relate to adjacent pixels The purpose of this technique is to minimize the average error between readed and printed densities Density data for adjacent pixels is modified by diffusing errors on the objective pixel into several pixels which are than binarized This maintains high grayscale levels and resolution during reading while suppressing moire patterns by dotted halftone images such as newspaper photo graphs Filtering The quality of images written in pencil or ballpoint pen and readed depends on the reflective light characteristics of the ink or lead Dropped pixel s may produce out lines g
103. errors and equipment errors and what the operator should do to recovery M 3099GX GH OEM M anual Conventions Chapter 6 Document Specification Chapter 6 provides document specifications size type limitations grounding color area drop out color and job separation sheet for the scanner Chapter 7 Consumables and Accessories Chapter 7 provides consumables and accessories Chapter8 Cleaning Chapter 8 provides cleaning locations and frequencies cleaning tools and procedures It is recommended that you thoroughly familiarize yourself with the contents of this manual before attempting to use the scanner Operators in particular must have read Chapter 4 Basic Operation Special information such as warnings cautions are indicated as follows WARNING A WARNING indicattes that personal injury may result if you do not follow a procedure correctly CAUTION A CAUTION indicates that damage to the scanner may result if you do not follow a procedure correctly NOTICE A NOTICE provides how to tips or suggestions to help you perform a procedure correctly NOTEs are particularly useful for first time users M 3099GX GH OEM M anual Contents CHAPTER 1 OVERVIEW e 1 1 Scanner Types e 1 1 utter ide 1 4 Coon cO EO Dun eiie a odia ide ee n B 1 5 Configuration of tlie SCafifl 1 5 Atrangement gb TUNES
104. es the location size and scanning method used for a window The set window data header is defined in Table 3 33 M 3099GX GH OEM M anual Table 3 33 Set Window Data Header Bit 7 6 5 4 3 Byte 0 Reserved 1 Reserved 2 Reserved 3 Reserved 4 Reserved 5 Reserved 6 MSB Window Descriptor Length 7 LSB The window descriptor length specifies the length in bytes of a single window descriptor Each descriptor shall be of equal length The first forty eight bytes are defined in this standard and the remaining bytes in each descriptor are vendor specific M 3099GX GH OEM M anual 3 57 INTERFACE Table 3 34 Window descriptor Bytes Bit 7 6 5 4 3 2 1 0 Byte 0 Window Identifier 1 Reserved Auto 2 MSB X Axis Resolution m Lu dq LSB 4 MSB Y Axis Resolution PM 57 LSB 6 MSB X Axis Upper Left Foo fo LSB 10 MSB Y Axis Upper Left LSB 14 MSB Window Width m Lal o LSB 18 5 Window Length MS fay LSB 22 Brightness 23 Threshold 24 Contrast 25 Image Composition 26 Bit Per Pixel 27 1 5 Halftone Pattern 28 qo LSB 29 RIF Reserved Padding Type 30 MSB Bit Ordering LSB 32 Compression Type 33 Compression Argument Reserved 39 40 LN Vendor Specific Parameter By
105. et routine within the target known as an I L nexus to be re established Only one logical unit shall be identified for any connection if a target receives a second shall go to BUS FREE phase see unexpected disconnect ANSI SCSI 2 6 1 1 The treatment of other logical unit addressing errors is described in ANSI SCSI 2 7 5 Whenever an I L nexus is established by an initiator that is allowing disconnection the Initiator shall ensure that the current pointers are equal to the saved pointers for that particular logical unit or target routine implied restore pointers operation shall occur as a result of a reconnection ABORT Init Targ The ABORT message is sent from the initiator to the target to clear any I O process for the I T x nexus The target shall go to the BUS FREE phase following successful receipt of this message The pending data status and I O processes for any other nexus shall not be cleared Previously established conditions including MODE SELECT parameters reservations and extended contingent allegiance shall not be changed by the ABORT message 3 102 M 3099GX GH OEM M anual BUS DEVICE RESET Init The BUS DEVICE RESET message is sent from an initiator to direct a target to clear all I O processes on that SCSI device This message forces a hard reset condition to the selected SCSI device The target shall go to the BUS FREE phase following successful receipt of this message Th
106. eted C A status Hardware error Abnormal command Abnormal parameter M edium error status REQUEST SENSE command Other command Error detail reported cleared C A status released 3 122 30996 OEM M anual Specifiable items for window parameter Window parameter items has some limitation owing to combination of their mutual functionality The table below shows such limitations Image Composition Line Art Halftone Item X Y resolution Upper Left X 4 4 Width Length Threshold V vd Bit Per Pixel 01 01 Halftone Pattern RIF Reverse Image Format 4 4 Outline Extraction O Image Emphasis Automatic Separation Mirror Image Paper Size Simplified Dynamic Threshold Dynamic Threshold White Level Follower Specifiable and effective 7 Effective if automatic separation is specified otherwise ignored V Specifiable but not effective if image emphasis is specified V Specifiable but not effective Specifiable but not effective if outline extraction is specified blank Not specifiable M 3099GX GH OEM M anual 3 123 3 124 M 3099GX GH OEM M anual CHAPTER BASIC OPERATION This chapter provides power switch operation operator panel arrangement and functions messages and replacement of co
107. evice CCD image sensors 1 1 Doouble feed detection B 2 B 3 CLEANING 8 1 Drop out Color 6 7 M 3099GX GH OEM M anual IN 1 Drop out color standards 6 7 Duplex circuit back side 1 8 Duplex Scanning 3 116 Ejection sensor 8 9 Electrical Specifications 2 2 ENDORSER Command 3 92 Endorser Control 3 117 Environmental Specifications 2 2 ERROR PROCESSING AND RECOVERY 5 1 Features 1 4 filtering 1 10 General 2 1 General Procedure for Initializing Devices 3 111 Gray scale 2 1 Grounding Color Area 6 6 Hold Time 3 13 Hopper 1 6 Hopper stacker capacity 2 1 Hopper time B 3 B 13 IDENTIFY Init gt Targ 3 104 Image processing circuit 1 8 Information Transfer Phases 3 19 INITLATOR DETECTED ERROR Init gt Targ 3 105 Inquiry Command 3 32 Interface 2 1 Interface circuit 1 8 Interface control 1 9 Inversion function 1 10 Job Separation Sheet 6 8 Lamp Replacement 4 10 LCD contrast B 2 B 8 LCD display 4 5 Light source 2 1 Loading Document 4 9 Main control unit 1 9 Memory board 1 8 Message 3 99 MESSAGE IN Phase 3 23 Message List 4 8 MESSAGE OUT Phase 3 24 MESSAGE PARITY ERROR Init Targ 3 105 Message Phase 3 23 MESSAGE REJECT Init lt gt Targ 3 106 Mirror image output function 1 10 Mode Parameter 3 88 MODE SELECT 6 Command 3 86 MODE SENSE 6 Command 3 87 Motor driver circuit 1 8 Multiple READ disconnect disabled 3 119 Multiple READ disconnect enabled 3 120 IN 2 M 3099
108. fault setting is OFF Endorser is not used The initial number The default setting 15 00000 The specifiable range is from 00000 to 65535 NOTICE If the specified value exceeds acceptable range returning to SETUP menu is failed Method of Increment gt In case of the initial value is 00001 gt 00001 1 page 00002 2 pages L L 65534 65534 pages 65535 65545 pages NOTICE When it is not set depending on operator panel by host no blinking You can not change the setting SETUP MODE When the setting is set ON depending on operator panel the direction of printing is 20 mm from read reference position B3 9 Setting reset method of endorser When you set the reset method of endorser you must see Section A2 3 of Appendix A The default setting is ON The print number will be reset when HOPPER EMPTY is detected M 3099GX GH OEM M anual B 9 B3 10 Reset of endorser W hen you reset the number to the initial number you must see Section A2 4 of Appendix A B3 11 Reset of ink counter W hen you reset the ink counter you must see Section A2 5 of Appendix A B3 12 Setting SCSI ID When you the SCSI ID you must set as follows lt lt SETUP MODE gt gt SCSI ID SET Screen 24 SCSI ID SET Screen 25 Screen 2 press M ode 1 twelve times to go to theSCSI ID SET screen Screen 24 G2 Press M ode 2
109. ge from the initiator the target shall respond by sending a MESSAGE REJECT message to the initiator M 3099GX GH OEM M anual 3 103 IDENTIFY Init Targ The IDENTIFY message Table 3 86 is sent by either the initiator or the target establish an I L nexus Table 3 86 IDENTIFY message Bit 7 6 5 4 3 2 1 0 Identify DiscPriv LUNTAR Reserved Reserved LUNTRN The Identify bit shall be set to one to specify that this is an IDENTIFY message disconnect privilege DiscPriv bit of one indicates that the initiator has granted the target the privilege of disconnecting A DiscPriv bit of zero specifies that the target shall not disconnect This bit is not defined and shall be set to zero when an IDENTIFY message is sent by a target A logical unit target LUNTAR bit of zero specifies that the I O process is directed to or from a logical unit A LUNTAR bit of one specifies that the I O process is directed to or from a target routine This scanner supports direction to logical unit LUNTAR bit is zero only The logical unit number target routine number LUNTRN field specifies a logical unit number if the LUNTRN bit is zero The response to an invalid value in the LUNTRN field is described in ANSI SCSI 2 7 5 3 An IDENTIFY message is invalid if a reserved bit is set to one or if the LUNTAR bit is set to one this scanner may respond to an invalid IDENTIFY message by immediately sendi
110. ge of SDTR message implies an agreement as follows Responding Device SDTR response Implied Agreement 1 Non zero REQ ACK offset Each device transmits data with a transfer period equal to or greater than and a REQ ACK offset equal to or less than the values received in the other device s SDTR message 2 REQ ACK offset equal to zero Asynchronous transfer 3 MESSAGE REJECT message Asynchronous transfer See ANSI SCSI 2 6 6 21 for details of SYNCHRONOUS TRANSFER REQUEST message M 3099GX GH OEM M anual 3 109 INTERFACE Command Sequence This chapter describes about command and phase sequence related to host system SCSI 2 introduced PHASE MESSAGE system etc for interfacing other than simple command passing therefore a lot of sequences can be considerable Below shows some typical case and out recommendations of implementation SCSI protocol to the system System Initialization The following list of information is assumed necessary and sufficient for normal system initialization 1 A list of each installed and powered on SCSI device for each SCSI address SCSI devices that are not powered on are treated as not installed assuming that the terminators are powered from a source other than unexpected SCSI devices 2 A list of the installed logical units for each SCSI device Unpowered or failing logical units may not be completely identifiable 3 The device type for each available logical unit 4 The manufa
111. hest setting one being the lowest setting and 128 being the nominal setting M 3099GX GH OEM M anual 3 61 Table 3 37 Contrast Value Contrast 00h Default same to 80h Olh Soften 80h Normal FFh Harden Image Composition 00h Black and white 01h halftoned The image composition field specifies the type of scan operation requested The image composition is defined as shown in Table 3 38 Table 3 38 Image Composition Codes Code Description 00h Bi level black and white 01h Dithered halftone black amp white 02h to FFh Reserved Bits Per Pixel O1h 1bit per pixel The bits per pixel field specifies the number of bits used to represent the intensity of a single color Halftone Table 3 39 3 40 The halftone field specifies the level of halftone at which the scan data is converted to binary data The values in this field are vendor specific This halftone field is used in conjunction with the image composition field Fujitsu defines this field two subfields to fitst byte as Halftone Type field and second byte as Halftone Pattern Halftone type OOh default Ol h dither O2h error diffusion Halftone Type field specifies method of halftoning shown in Table 3 39 A value of zero indicates default halftoning method of the device 3 62 M 3099GX GH OEM M anual Table 3 39 Type Value Halftoning method 00h Default same to 01h dither
112. his position function specifies that the object shall be positioned for removal If upon receipt of this command there is no object loaded the target shall return a GOOD status This condition shall not be considered as an error If the target is unable to unload the object i e paper jam or mis feeding condition the target shall return CHECK CONDITION status and set the sense key sense to MEDIUM ERROR Load Object The position function specifies that the object is to be loaded and positioned to the base line If upon receipt of this command there is a object already loaded the target shall returns GOOD status This condition shall not be considered as an error If an object is not loaded and the target is unable to load an object the target shall return CHECK CONDITION status and set the EOM bit to one and the sense key to MEDIUM ERROR Count 000000h Reserved SEND Command The SEND command Table 3 56 transfers data from the initiator to the target Table 3 56 SEND Command Bit 7 6 5 4 3 2 1 0 Byte 0 Operation Code 2Ah Logical Unit Number Reserved Data Type Code Reserved Data Type Qualifier N WIN 27 ies Transfer Length Control M 3099GX GH M anual Data Code 02h Halftone Mask 03h Gamma Function 90h Endorser Data Data Type Qualifier 0 to 7 Halftone Mask 0 to 7 Gamma Function Data Type Co
113. hitecture includes eight distinct phases a BUS FREE phase b ARBITRATION phase c SELECTION phase d RESELECTION phase e COMMAND phase DATA phase These phases are collectively termed g STATUS phase the information transfer phase h MESSAGE phase The SCSI bus can never be in more than one phase at any given time In the following descriptions signals that are not mentioned shall not be asserted BUS FREE Phase See ANSI SCSI 2 6 1 1 for details The BUS FREE phase indicates that there is no current I O process and that the SCSI bus is available for a connection SCSI devices shall detect the BUS FREE phase after the SEL and BSY signals are both false for at least a bus settle delay SCSI devices shall release all SCSI bus signals within a bus clear delay after the BSY and SEL signals become continuously false for a bus settle delay If an SCSI device requires more than a bus settle delay to detect the BUS FREE phase then it shall release all SCSI bus signals within a bus clear delay minus the excess time to detect the BUS FREE phase The total time to clear the SCSI bus shall not exceed a bus settle delay plus a bus clear delay M 3099GX GH OEM M anual 3 15 If an initiator detects the release of the BSY signal by the target at any other time the target is indicating an error condition to the initiator The target may perform this transition to the BUS FREE phase independent of the state of the ATN signal The initiator shall
114. ilure sense key 4h 4h HARDWARE ERROR Indicates that the target detected a non recoverable hardware failure for example controller failure device failure parity error etc while performing the command or during a self test 5h ILLEGAL REQUEST Indicates that there was an illegal parameter in the command descriptor block or in the additional parameters supplied as data for some commands FORMAT UNIT SEARCH DATA etc If the target detects an invalid parameter in the command descriptor block then it shall terminate the command without altering the medium If the target detects an invalid parameter in the additional parameters supplied as data then the target may have already altered the medium This sense key may also indicate that an invalid INDENTIFY message was received 6h UNIT ATTENTION Indicates that the removable medium may have been changed or the target has been reset See ANSI SCSI 2 7 9 for more detailed information about the unit attention condition Bh ABORTED COMMAND Indicates that the target aborted the command The initiator may be able to recover by trying the command again M 3099GX GH OEM M anual Information 00000000h If ILI 0 The information field is valid when ILI bit is set to 1 for READ command the difference of the required length Transfer Length minus the actual length in bytes Negative values are indicated by two s complement notation INTERFACE
115. indicates available steps of the Brightness If zero is pecified Brightness Control is not supported Threshold Step FFh 255 steps Threshold Step field indicates available steps of the Threshold If zero is pecified Threshold Control is not supported Contrast Step FFh 255 steps Contrast Step field indicates available steps of the Contrast If zero is pecified Contrast Control is not supported Number of Resident Dither 0100xxxxb 4 patterns Number of Resident Dither field indicates number of resident Dither patterns in 4 bits If zero is specified no dither pattern is available Number of Registerable Dither xxxx1000b 8 patterns Number of Registerable Dither field indicates registrable dither patterns in 4 bits If zero is specified no dither pattern is registrable Number of Resident Gamma Function 0100xxxxb 4 patterns Number of Resident Gamma Function field indicates number of resident gamma functions in 4 bits If zero is specified no gamma function is available Number of Registrable Gamma Function xxxx1000b 8 patterns Number of Registrable Gamma Function field indicates registrable gamma functions in 4 bits If zero is specified no gamma function is registrable M 3099GX GH OEM M anual Table 3 23 Image Control Function Byte Bit Description 82 nnnnnnnnb Brightness Steps 83 nnnnnnnnb Threshold Steps 84 nnnnnnnnb Contrast Steps 85 00000000b Reserved 86 n
116. ing a message If the target receives all of the message byte s successfully 1 no parity errors it shall indicate that it does not wish to retry by changing to any information transfer phase other than the MESSAGE OUT phase and transfer at least one byte The target may also indicate that it has successfully received the message byte s by changing to the BUS FREE phase e g ABORT or BUS DEVICE RESET messages The SCSI bus has two asynchronous conditions the attention condtion These conditions cause the SCSI device to perform ceratin actions and alter the phase sequence Attention Condition The attention condition allows an initiator to inform a target that the initiator has a message ready The target may get this message by performing a MESSAGE OUT phase The initiator creates the attention condition by asserting ATN at any time except during the ARBITRATION or BUS FREE phases The initiator shall negate the ATN signal at least two deskew delays before asserting the ACK signal while transferring the last byte transferred in a bus phase for the attention condition to be honored before transition to a new bus phase Asserting the ATN signal later might not be honored until a later bus phase and then may not result in the expected action See ANSI SCSI 2 6 2 1 for details M 3099GX GH OEM Manual Reset Condition The reset condition is used to immediately clear all SCSI devices from the bus This condition shall take p
117. initiator to the target during the DATA OUT phase parameter list length of zero indicates that no data shall be transferred This condition shall not be considered as an error 3 86 M 3099GX GH OEM M anual The target shall terminate the command with CHECK CONDITION status if the parameter list length results in the truncation of any mode parameter header mode parameter block descriptor omitted in this scanner or mode page The sense key shall be set to ILLEGAL REQUEST and the additional sense code shall be set to PARAMETER LIST LENGTH ERROR The mode parameter list for the MODE SELECT and MODE SENSE commands are defined in paragraph Mode Parameter MODE SENSE 6 Command The MODE SENSE 6 command Table 3 67 provides a means for a target to report parameters to the initiator It is a complementary command to the MODE SELECT 6 command Table 3 67 MODE SENSE 6 Command Bit Byte 7 6 5 4 0 Operation Code 1Ah Logical Unit Number Reserved DBD Reserved PC Page Code Reserved Allocation Length 1 2 3 4 5 Control DBD disable block descriptors Ob This bit of zero indicates that the target may return zero or more block descriptors in the returned MODE SENSE data see ANSI SCSI 2 8 3 3 at the target s discretion A DBD bit of one specifies that the target shall not return any block descriptors in the returned MO
118. ion Belt Pad CA01023 G290 Up to 300 000 sheets or more Print head CA01023 0701 Black ink for endorser option Ten print heads are packed Each print head has the life of 20 000 sheets at 10 characters per sheet M 3099GX GH OEM M anual 7 1 CONSUMABLES AND ACCESSORIES Accessories Table 7 2 lists accessories of the scanner Table 7 2 Accessories Name Quantity Remark Power cable 100 Vor 200 V 1 Operator s guide 1 Terminator 1 Consumable kit 1 7 2 M 3099GX GH OEM M anual CHAPTER Cleaning Locations and Frequencies CLEANING This chapter provides cleaning locations and frequencies cleaning tools and Table 8 1 lists cleaning locations and frequencies of the scanner procedure Table 8 1 Cleaning locations and frequencies Front side reading timing detection Ejection detection Locations Tools Frequencies Front side lamp Dry cloth Every 50 000 sheets Roller and belt Cleaning sheet Every 50 000 Cleaner F2 sheets Dry cloth and isopropyl alcohol Transport path Glass surface Sensor Document width Every 200 000 tops detection Dry cloth and sheets Document detection alcohol Note Depending on use it may be necessary to clean more frequently M 3099GX GH OEM Manual 8 1 Cleaning Tools The tools required for cleaning are as follows
119. is not required but it can be available In the simplex mode only 00h front page is specifiable READ Command The READ command Table 3 60 requests that the target transfer data to this initiator Table 3 60 READ Command Bit 7 6 5 4 3 2 1 Byte 0 Operation Code 28h Logical Unit Number Reserved Data Type Code Reserved Data Type Qualifier Nn 9 Transfer Length Control 3 80 M 3099GX GH OEM M anual Data Codes 00h Image 80h Pixel Size 81h Detected Paper Information The transfer data type distinguishes between the different types of data which may be transferred between the initiator and the target The types of transfers are specified in Table 3 61 Data Type Code and Data Type Qualifier are commonly used with SEND command Table 3 61 Data Type Codes Code Description Command 00h Image READ Olh Vendor Specific 02h Halftone Mask SEND 03h Gamma Function SEND 04h 7Fh Reserved 80h FFh Vendor specific 80h Pixel Size READ 81h Detected Paper Information READ others Reserved Data Type Qualifier The data type qualifier field provides a means to differentiate data transfers of the same data type code The values used in this field are vendor specific This scanner uses this field for Image Data as follows Byte 4 Reserved Byte 5 Window Id
120. is target shall create a unit attention INTERFACE condition for all initiators see ANSI SCSI 2 7 9 COMMAND COMPLETE Init Targ The COMMAND COMPLETE message is sent from a target to an initiator to indicate that the execution of an I O process has completed and that valid status has been sent to the initiator After successfully sending this message the target shall go to che BUS FREE phase by releasing the BSY signal The target shall consider the message transmission to be successful when it detects the negation of ACK for the COMMAND COMPLETE message with the ATN signal false DISCONNECT Init Targ The DISCONNECT message is sent from a target to inform an initiator that the present connection is going to be broken the target plans to disconnect by releasing the BSY signal but that a later reconnect will be required in order to complete the current I O process This message shall not cause the initiator to save the data pointer After successfully sending this message the target shall go to the BUS FREE phase by releasing the BSY signal The target shall consider the message transmission to be successful when it detects the negation of the ACK signal for the DISCONNECT message with the ATN signal false Targets which break data transfers into multiple connections shall end each successful connection except possibly the last with a SAVE DATA POINTER DISCONNECT message sequence If the target receives the DISCONNECT messa
121. it means that the signal may be actively driven false or may be simply released in which case the bias circuitry pulls it false at the option of the implementor Signal Source Table 3 4 indicates which type of SCSI device is allowed to source each signal No attempt is made to show if the source is driving asserted driving negated or is passive All SCSI device drivers that are not active sources be in the passive state The RST signal may asserted by any SCSI device at any time M 3099GX GH M anual 3 9 Table 3 4 Signal Source C D 1 0 MSG ACK DB 7 0 Bus Phase BSY SEL DB P BUS FREE None None None None None ARBITRATION All Win None None SID SELECTION I amp T Init None Init Init RESELCTION I amp T Targ Targ Init Targ COMMAND Targ None Targ Init Init DATA IN Targ None Targ Init Targ DATA OUT Targ None Targ Init Init STATUS Targ None Targ Init Targ MESSAGE IN Targ None Targ Init Targ MESSAGE OUT Targ None Targ Init Init The signal shall be driven by all SCSI devices that are actively S ID Init None Win Targ arbitrating A unique data bit the SCSI ID shall be driven by each SCSI device that is actively arbitrating the other seven data bits shall be released i e not driven by this SCSI device The parity bit DB P may be released or driven to the true state but shall never be driven to the false state during this phase The signal shall
122. ith an ACK pulse If the I O signal is false transfer to the target the initiator shall tranfer one byte for each REQ pulse received After receiving the leading edge of a REQ pulse the initiator shall first drive the DB 7 0 P signals to their desired values delay at least one deskew delay plus one cable skew delay then assert the ACK signal The initiator shall hold the DB 7 0 P signals valid for at least one deskew delay plus one cable skew delay plus one hold time after the assertion of the ACK signal The initiator shall assert the ACK signal for a minimum of an assertion period The initiator may then negate the ACK signal and may one hold time of the transition of the ACK signal to true COMMAND Phase The COMMAND phase allows the target to request command information from the initiator The target shall assert the C D signal and negate the I O and MSG signals during the REQ ACK handshake s of this phase Data Phase The data phase is a term that encompasses both the DATA IN phase and the DATA OUT phase 3 22 M 3099GX GH OEM M anual DATA IN Phase The DATA IN phase allows the target to request that data be sent to the initiator from the target The target shall assert the I O signal and negate the C D and MSG signals during the REQ ACK handshake s of this phase DATA OUT Phase The DATA OUT phase allows the target to request that data be sent from the target to the initiator The target shall negate the
123. k parameter header is defined in Table 3 70 3 88 M 3099GX GH OEM M anual Table 3 70 Mode Parameter Header 6 Bit 7 6 5 4 3 2 1 0 Byte 0 Mode data length 1 Medium type Reserved 2 Device specific parameter Reserved 3 Block descriptor length Reserved When using the MODE SENSE command the mode data length field specifies the length in bytes of the following data that is available to be transferred The mode data length does not include itself When using the MODE SELECT command this field is reserved Medium Type is reserved Device Specific Parameter Block Descriptor Length are Reserved for Scanner Device The mode page format is defined in Table 3 71 Table 3 71 Mode Page Format Bit 7 6 5 4 3 2 1 0 Byte 0 PS Reserved Page Code 1 Page Length 2 Mode Parameter n Each mode page contains a page code a page code length and a set of mode parameters PS parameters savable Ob not saved When using the MODE SENSE command a parameters savable PS bit of one indicates that the mode page can be saved by the target in non volatile vendor specific location A PS bit of zero indicates that the supported parameters cannot be saved When using the MODE SELECT command the PS bit is reserved This scanner does not have page save function M 3099GX GH OEM M anual 3 89 Page Code 3Dh Lamp Timer 3Eh Job
124. l The target shall assert the REQ signal for a minimum of an assertion period The target shall then wait at least the greater of a transfer period from the last transition of the signal to true or a minimum of a negation period from the last transition of the ACK signal to false before asserting the ACK signal The initiator shall send one pulse on the ACK signal for each REQ pulse received The ACK signal may be asserted as soon as the leading edge of the corresponding REQ pulse has been received The Initiator shall assert the ACK signal for a minimum of an assertion period The initiator shall wait at least the greater of transfer period from the last transition of the ACK signal to true or for a minimum of a negation period from the last transition of the ACK signal to false before asserting the ACK signal M 3099GX GH OEM M anual 3 21 If the I O signal is true transfer to the initiator target shall first drive the DB 7 0 P signals to their desired values wait at least one deskew delay plus one cable skew delay then assert the REQ signals The DB 7 0 P signals shall be held valid for a minimum of one deskew delay plus one cable skew delay plus one hold time after the assertion of the REQ signal The target shall assert the signal for a minimum of an assertion period The target may then negate the REQ signals within one hold time of the transition of the signal to true The initiator shall then respond w
125. l 3 65 Vendor Unique Identification Code O0h Image Processing Parameter The vendor unique identification code field specifies type if vendor unique parameter Gamma Correction 00h to 03h resident 80h to 87h downloaded This gamma correction field specifies Gamma Correction Table Table 3 43 Gamma Correction Table Value Gamma Correction Table 00h Default Normal 01h Normal 02h Soft 03h Sharp 04h to 7Fh Reserved 80h to 87h Downloaded Gamma Table 88h to FFh Reserved Outline Extract 00h 80h with IPC2 The outline extract field specifies contour extraction of image Table 3 44 Outline Extract Value Description 00h Default Disable Outline Olh to 7Fh Reserved 80h Enable Outline 81h to FFh Reserved 3 66 M 3099GX GH OEM Manual Image Emphasis 00h 80h with IPC2 The image emphasis field specifies filtering function 01h to 7Fh specifies Emphasis 80h to FFh specifies Smoothing Table 3 45 Image Emphasis Value Description 00h Disable Olh to 2Fh Low Emphasis 30h to 4Fh Medium Emphasis 50h to 7Fh High Emphasis 80h to FFh Smoothing Automatic Separation 00h 80h with IPC2 The automatic separation field specifies automatic separation function Table 3 46 Automatic Separation Value Description 00h Default Disable Automatic Separation Olh to 7Fh Reserved
126. ler Replacement Replace the pick roller as follows Upper transport unit Operator panel Power switch Lever Pick roller en laf LUTEALE Za FSI 4 7 7 Pick roller U shaped clip section White mark e Turn off the power switch 2 Open the upper transport unit See page 4 2 3 Put off U shaped clips on both ends of the pick roller shaft Pull the pick rollers outward each other to remove 2 Install a new pick rollers and put the U shaped clips on the pick roller shaft Close the upper transport unit See page 4 2 NOTICE When you install pick rollers make sure that the white marks on the side of the both pick rollers be in the right hand side of the scanner 4 18 M 3099GX GH OEM M anual Belt Replacement Replace the belt as follows WARNING Wait at least 3 minutes after turning off the power before replacement Upper transport unit Operator panel Turn off the power switch Make sure that the hopper table is at the bottom BASIC OPERATION 2 Open the upper transport unit See page 4 2 L Power switch ever 3 Disconnect two relay Lever green connectors on the roller ASY 4 Push the two levers green towards each other to dis engage with the upper locking holes and lower down the two levers until they engage with the two levers locking holes Roller ASY Guide plate 6 Lift the documen
127. llowing shows simplex mode sequence For Duplex mode refer to 3 9 4 2 RESERVE UNIT SEND Endorser Data ENDORSER Start SET WINDOW ID 00h 5 ECT POSITION Load Object OBJ ECT POSITION Unload Object ENDORSER Stop RELEASE UNIT Reserve exclusive use ofthe scanner Send Endorser Data Start endorser function by sending identifier with STOP bit 0 Specify document scanning parameter Send Halftone M ask and or Gamma Function data if required Feed document into ADF This command is omissible because SCAN or READ command automatically feeds in a document Start scanning operation This command is omissible beacuse READ command automatically starts scanning Transfer image data from scanner READ command would be issued one or more The details of READ command sequence is 4 9 5 Feed out document from ADF This command is omissible because end of scanning automatically feeds out document Stop endorser function by sending identifier with STOP bit 1 Release exclusive use of the scanner 1 Thisloop is used to scan a batch of document 2 Thisloop is used to scan a batch of identical format document at maximum speed M 3099GX GH OEM M anual 3 117 READ command sequences and phase progression This scanner initially has image buffer memory different from former Fujitsu image scanner
128. lows Screen 2 press M ode 1 four times to go MENS TUPA aal to the BUZZER SET screen Screen 16 BUZZER SET TUE 8 Press M ode 2 to see Screen 17 If ON is displayed the buzzer will ring when the error is occured If OFF is displayed it wouldn t BUZZER SET The ON or OFF status flips each time pn ON you press M ode 1 T he status will be set in EEPROM automatically Screen 17 9 you want to return to Screen 16 press M ode 2 W hen yo closethe setup mode go toQ B3 5 Setting pre pick W hen you set the using pre pick you must set as follows QOAt Screen 2 press M ode 1 five times to go Lees S lt SETUPMODE gt tothe PREPICK SET screen Screen 18 PREPICK SET RTRT 0 Press M ode 2 to see Screen 19 If ON is displayed the pre picking will be done when the document 15 If OFF is displayed it PREPICK SET wouldn t The ON or OFF status flips SETUP MODE o B EH each time you press M ode 1 T he status will beset in EEPROM automatically Screen 19 02 you want to return to Screen 18 press M ode 2 When you close the setup mode go to 9 M 3099GX GH OEM M anual B 7 B3 6 Adjusting LCD contrast W hen you adjust theLCD contrast you must set as follows lt lt 5 MODE gt gt LCD CONTRAST Screen 20 LCD CONTRAST Q3 At Screen 2 press ode 1 six times to go to LCD CONTRA
129. ly use sense keys for high level error recovery procedures Additional INTERFACE sense codes provide further detail describing the sense key Additional sense code qualifiers add further detail to the additional sense code The additional sense code and additional sense code qualifier can be used by initiators where sophisticated error recovery procedures require detailed information describing the error and exception conditions The sense key field is mandatory and indicates generic information describing an error or exception condition The sense key used are defined in Table 3 29 M 3099GX GH M anual 3 51 Table 3 29 Sense Key Descriptions Sense Key Description Oh NO SENSE Indicates that there is no specific sense key information to be reported for the designated logical unit This would be the case for a successful command or a command that received CHECK CONDITION or COMMAND TERMINATED status because one of the filemark EOM or ILI bits is set to one 2h NOT READY Indicates that the logical unit addressed cannot be accessed Operator intervention may be required to correct this condition 3h MEDIUM ERROR Indicates that the command terminated with a non recovered error condition that was probably caused by a flaw in the medium or an error in the recorded data This sense key may also be returned if the target is unable to distinguish between a flaw in the medium and a specific hardware fa
130. ly unit mechanism driver an image processing control and an interface control This scanner has the following circuit configuration Operator panel Control circuit MPU Video circuit front side back side nterface circuit Duplex circuit back side Motor driver circuit including a stepper motor a clutch driver Power supply unit mage processing circuit IPC II option Memory board Figure 1 5 shows control block diagram Host Interface Control Video Mechanism machine circuit circuit circuit unit M PU front side Video ADF circuit MF back side Image processing circuit Il option Power Duplex front side supply circuit 9 l Image M emory processing y circuit Il option 100to 120 VAC M otor back side 220to 240 VAC Power driver switch circuit Operator panel Figure 1 5 Control block diagram 1 8 M 3099GX GH OEM M anual Main control unit DES This scanner is controlled by a 80C186 MPU This scanner consists of a ROM as a program area internal registers an external RAM as a work area gate arrays for the MPU peripheral and video circuits dither processing and Y conversion RAMs and error diffusion Interface control SCSI 2 interface SCSI small computer system interface circuit consists of SP
131. mA sinking signal assertion 2 5 to 5 25 volts dc signal negation Input characteristics Low level input voltage High level input voltage Low level input current High level input current Minimum input hysteresis 0 0 to 0 8 volts dc 2 0 to 5 25 volts dc 0 4 to 0 0mA at Vi 0 5 volts dc 0 0 to 0 1mA at Vi 2 7 volts dc 0 2 volts dc Connector pin assignments for signal lines See Table 3 2 3 4 M 3099GX GH OEM M anual Termination All signals not defined as RESERVED GROUND or TERMPWR shall be terminated at both ends of the cable The Implementor may choose one of the following two methods to terminate each end see ANSI SCSI 2 ANSI SCSI 2 5 4 Electrical description INTERFACE Single ended alternative a Passive terminator TERMINATOR POWER SIGNAL 220 Q 300 GROUND Figure 3 2 Alternative 1 termination for Single Ended Devices Single ended alternative b Active terminator R3 gt Low dropout voltage regulater Vin Imax gt 600mA Vout Vout 2 85V 77 ule ES See Note 1 RI ud o Vadj Component Description RI 1210 196 0 25W R2 R2 154 Q 1 0 25W R3 R20 110 Q 1 C1 10 uF Alum 15V or 4 7 uF Tant 15V R20 C2 150 uF Alum 10V or 22 uF Tant 10V ESR at 120 Hz lt 4 C3 0 1 uF Ceramic 25V NOTES 1 voltage regulator shown is an adjustable type with Vref 1 25V Rl and R2
132. mmand See ANSI SCSI 2 7 2 5 The INQUIRY command Table 3 11 requests that information regarding parameters of the target and its attached peripheral device s be sent to the initiator An option allows the inititor to request additional information about the target or logical unit See ANSI SCSI 2 7 2 5 2 Vital Product Data 3 32 M 3099GX GH OEM M anual Table 3 11 INQUIRY Command Bit 7 6 5 4 3 2 1 0 Byte 0 Operation Code 12h 1 Logical Unit Number Reserved EVPD 2 Page Code 3 Reserved 4 Allocation Length 5 Control EVPD Enable Vital Product Data This bit of one specifies that the target shall return the optional vital product data specified by the page code field If the target does not support vital product data and this bit is set to one the target shall return CHECK CONDITION status with the sense key set to ILLEGAL REQUEST and an additional sense code of INVALID FIELD IN CDB This bit of zero specifies that the target shall return the standard INQUIRY data If the page code field not zero the target shall return CHECK CONDITION status with the sense key set to ILLEGAL REQUEST and an additional sense code of INVALID FIELD IN CDB Page Code This field specifies which page of vital product data information the target shall return see ANSI SCSI 2 7 3 4 The supported vital product data in this scanner is Page Code FOh The INQUIRY command shall return CH
133. mporary Error is returned to the host computer and an Open the upper transport unit and remove the document on the transport path Then close the unit error message is displayed on Return the the LCD display jammed or The hopper table is lowered double fed to the bottom document to the hopper and read it again 1 More detailed error messages are shown by the method specified in maintenance manual 2 Common action at temporary errors is 0 5 second interval buzzer for 3 seconds 3 The temporary errors are recovered by pressing the stop button M 3099GX GH OEM M anual 5 1 ERROR PROCESSING AND RECOVERY Table 5 1 Device and operator actions for temporary errors continued LCD display Scanner actions Action to recover HOPPER When a read operation is The error is EMPTY activated the pick sensor recovered by SPK goes off but not the hopper empty sensor SHE is off If an error is detected the hopper table is lowered Then Temporary Error is returned to the host computer and an error message is displayed on the LCD display The hopper empty sensor SHE goes on during reading The read operation is terminated normally After the document is ejected into the stacker the hopper table is lowered When a START READ or SENSE command is received from the host computer Temporary Error is returned This status is not detected
134. nd pull the roller ASY out with the other hand 6 Move the guide on the hopper table completely to the end 7 Hold both ends of the guide plate and press them down to remove the guide Adjust the separation pressure by using the separa tion pressure adjustment lever according to paper feed error as follows Slip feed Turn clockwise by 45 In crease the separation pressure Double feed Turn counter clockwise by 45 Decrease the separation pres sure Notice If the paper feed error reccur try this adjustment again until the lever stops C 2 M 3099GX GH M anual Glossary of Terms M size standard paper size used in Japan and other countries Paper is 210 x 297 mm 8 25 x 11 6 inches ASCII The acronym for American Standard Code for Information Interchange ASCII is a set of 256 codes numbered 0 to 255 used to communicate information between a computer and another device such as a scanner Automatic separation The image processing method to detect the difference between text and photos and choose the thresholding accordingly Automatic separation allows the scanner to switch between line mode and half tone mode in one pass Automatic start mode A mode that the scanner starts to read by the command from the host machine Bit The smallest unit of information in computer memory bit isa single digit either a 1 or a 0 in the binary numbering system Eight bits
135. ner M 3099GX GH OEM M anual 3 25 SCSI Bus Phases The order in which phases are used on the SCSI bus follows Sequences prescribed sequence The reset condition can abort any phase and is always followed by the BUS FREE phase Also any other phase can be followed by the BUS FREE phase but many such instances are error conditions The additional allowable sequences shall be as shown in Figure 3 5 The normal progression is from the BUS FREE phase to ARBITRATION from ARBITRATION to SELECTION or RESELECTION and from SELECTION or RESELECTION to one or more of the information tranfer phases COMMAND DATA STATUS or MESSAGE The final information transfer phase is normally the MESSAGE IN phase where a DISCONNECT or COMMAND COMPLETE message is transferred followed by the BUS FREE phase Reset or protocol error M ESSAGE OUT SELECTION IE COMMAND BUS FREE gt ole RESELECTION STATUS MESSAGE IN Figure 3 5 Phase Sequence 3 26 M 3099GX GH OEM M anual Commands ANSI SCSI 2 7 command is communicated by sending a command descriptor block to the target For several commands the command descriptor block is accompanied by a list of parameters sent during the DATA OUT phase The command descriptor block always has an operation code as its first byte and a control byte as its la
136. ng a MESSAGE REJECT message An implied RESTORE POINTERS message shall be performed by the initiator prior to the assertion of the ACK signal for the next phase for an inbound IDENTIFY message sent during reconnection 3 104 M 3099GX GH OEM M anual An implied RESTORE POINTERS message shall be performed by the initiator following successful identification of the nexus during the MESSAGE IN phase of reconnection and before the negation of the ACK signal for the next transfer following the successful identification INTERFACE INITIATOR DETECTED ERROR Init Targ The INITIATOR DETECTED ERROR message is sent from an initiator to inform a target that an error has occurred that does not preclude the target from retrying the operation The source of the error may either be related to previous activities on the SCSI bus or may be internal to the initiator and unrelated to any previous SCSI bus activity Although present pointer integrity is not assured a RESTORE POINTERS message or a disconnect followed by a reconnect shall cause the pointers to be restored to their defined prior status MESSAGE PARITY ERROR Init Targ The MESSAGE PARITY ERROR message is sent from the initiator to the target to indicate that it received a message byte with a parity error see ANSI SCSI 2 6 2 1 In order to indicate its intentions of during this message the initiator shall assert the ATN signal prior to its release of the ACK signal for the
137. ng edges of successive REQ pulses and of successive ACK pulses to meet the device requirements for successful reception of data REQ ACK Offset O Async 1 to 8 The REQ ACK offset is the maximum number of REQ pulses allowed to be outstanding before the leading edge of its corresponding ACK pulse is received at the target This value is chosen to prevent overflow conditions in the device s reception buffer and offset counter A REQ ACK offset value of zero shall indicate asynchronous data transfer mode a value of FFh shall indicate unlimited REQ ACK offset 3 108 M 3099GX GH OEM M anual The originating device the device that sends the first of the pair of SDTR message sets its values according to the rules above to permit it to receive data successfully If the responding device can also receive data successfully with those values or smaller transfer periods or larger REQ ACK offsets or both it returns the same values in its SDTR message If it requires a larger transfer period a smaller REQ ACK offset or both in order to receive data successfully it substitutes values in its SD TR message as required returning unchanged any value not required to be changed Each device when transmitting data shall respect the limits set by the other s SDTR message but it is permitted to transfer data with larger transfer periods smaller REQ ACK offsets or both than specified in the other s SDTR message The successful completion of an exchan
138. ngth 00000D80h 3456 dot Window Width and Window Length fields are maximum width and length those are available by the scanner The units are pixels counted by the basic resolution 00000110b Function Function field specifies functions supported by the scanner Each bit is set to 1 corresponding to Table 3 15 M 3099GX GH OEM M anual 3 39 INTERFACE Table 3 15 Function Bit Description 0 Data Over Flow Scanners that will cause data over flow sets this bit to 1 Image scanners that will not cause data over flow set this bit to 0 Support of Start Switch is not specified Bit 1 Binary Black and White Scanners support Black and White set this bit to 1 Scanners do not support Black and White set this bit to 0 Bit 2 Dither Halftone Scanners support Dither Halftone set this bit to 1 Scanners do not support Dither Halftone set this bit to 0 Bit3 Grayscale Scanners support Grayscale set this bit to 1 Scanners do not support Grayscale set this bit to 0 Steps of gray is not specified Bit 4 Reserved Bit 4 to 7 are Reserved in JBMS Bit 5 Binary RGB Color Scanners support RGB Color set this bit to 1 Scanners do not support RGB Color set this bit to 0 Bit 6 Dither Halftone RGB Color Scanners support Dither Halftone RGB Color set this bit to 1 Scanners do not support Dither Halftone RGB Color set this bit to 0 Bit 7 Grayscale RGB Color Scanners
139. nnnXXXXb Number of resident Dither XXXXnnnnb Number of registrable Dither 87 nnnnXXXXb Number of resident Gamma Function XXXXnnnnb Number of registrable Gamma Function Image Processing Function 10000001 01000000b without IPC2 11111111 01000000b with IPC2 Image Processing function field of each bit indicates supported Image Processing function Table 3 24 Image Processing Function Byte Bit Description 88 1XXXXXXXb Reverse Image Format X1XXXXXXb Dynamic Threshold Circuit XX1XXXXXb Simplified DTC XXX1XXXXb Outline Extract XXXX1XXXb Image Emphasis XXXXX1XXb Automatic Separation XXXXXX1Xb Mirror Image XXXXXXX1b White Level Follower 89 1XXXXXXXb Subwindow X1XXXXXXb Error Diffusion XX1XXXXXb Reserved XXX1XXXXb Reserved XXXX1XXXb Reserved XXXXX1XXb Reserved XXXXXX1Xb Reserved XXXXXXX1b Reserved M 3099GX GH OEM M anual 3 47 INTERFACE Compression Function 11100000 00000000b Compression Function field of each bit indicates Compression Functions supported by the scanner Table 3 25 Compression Function Byte Description 90 1XXXXXXXb MH X1XXXXXXb MR XX1XXXXXb MMR XXX1XXXXb JBIG XXXX1XXXb JPEG Base Line System XXXXX1XXb JPEG Extended System XXXXXX1Xb JPEG Independent Function XXXXXXX1b Reserved 91 00000000b Reserved Endorser Function 00000000 00000000b without ENDORSER 10000001 000000
140. nsumables Power Switch The power switch is located at the right side of the scanner Operation Figure 4 1 shows switch location Power switch Figure 4 1 Power switch location M 3099GX GH OEM M anual 4 1 BASIC OPERATION Opening the Upper Transport Unit 1 Liftthe lever below operator panel to open the upper transport unit from under WARNING Make sure that the upper transport unit is engaged in the LIFT up position on the LIFT up latch ammed document Closing the Upper Transport Unit Operator panel l Lift up the upper transport unit with both of your hands to release the LIFT up latch and then to lower down the upper transport unit with your hands WARNING Before lowering down the unit make sure that the area between the main machine and the upper transport unit is clear of all objects and fingers NOTICE Press the upper transport unit with both hands to secure the lock 4 2 M 3099GX GH OEM M anual Operator Panel The operator panel is located at right side in front view of this device The operator panel consists of an LCD display 24 columns x 2 lines 3 LEDs and 5 buttons Figure 4 2 shows layout of operator panel Power Read Check amp Co amp LCD 24 2 lines BASIC OPERATION Figure 4 2 Operator panel layout Operator panel function Table 4 1 lists button functions and Table 4 2 lists LED functions M 309
141. ntil the digit you want to change blinks Then press Mode 2 until the digit changes as you want The specifiable range is from 1 to 1999 sec in 1 sec step Press Mode 1 and Mode 2 at a time to see Screen 32 The settings are stored to EEPROM 65 When you close the setup mode go to 9 y P 5 12 M3099GX GH Manual B3 17 Setting hopper time W hen you set the hopper time you must set as follows lt lt SETUP MODE gt gt HOPPER TIMER Screen 34 HOPPER TIMER Screen 35 G6At Screen 2 press M ode 1 seventeen times to go to the HOPPER TIMER screen Screen 34 57 Press M ode 2 to see Screen 35 T he default setting is 7 sec 58At Screen 35 press M ode 1 until the digit you want to change blinks T hen press M ode 2 until the digit changes as you want T he specifiable range is from 0 to 30 sec in 1 sec Step 69 Press M ode 1 and M ode 2 at a time to see Screen 34 T he settings are stored to EEPROM 60 hen you close the setup mode to Q B3 18 Setting heater control W hen you set the heater control you must set as follows lt lt SETUP MODE gt gt HEATER CONTROL Screen 36 HEATER CONTROL Screen 37 63At Screen 2 press M ode 1 eighteen times to to the HEATER CONTROL screen Screen 36 62 M ode 2 to see Screen 37 If ON is displayed the heater control will be d
142. o a signal indicates active low The lines labeled RESERVED in the A cable contact assignment tables shall be connected to ground in the bus terminator assemblies or in the end devices on the SCSI cable The RESERVED lines should be open in the other SCSI devices but may be connected to ground The RESERVED nites lines in this scanner are opened SCSI Bus See ANSI SCSI 2 4 5 Communication on the SCSI bus is allowed between only two SCSI devices at any given time There is a maximum of eight SCSI devices Each SCSI device has an SCSI ID bit assigned as shown in Figure 3 4 DB 7 DB 6 DB 5 DB 4 DB 3 DB 2 DB 1 DB 0 SCSIID 10 7 ID 6 ID 5 10 4 10 3 ID 2 ID 1 ID 0 Figure 3 4 DATA BUS M 3099GX GH OEM M anual 3 7 SCSI Bus Signals See ANSI SCSI 2 4 6 Table 3 3 SCSI Bus Signals Signal Description BSY BUSY An OR tied signal that indicates that the bus is being used SEL SELECT An OR tied signal used by an initiator to select a target or by a target to reselect an initiator C D A signal driven by a target that controls the CONTROL DATA direction of data movement on the DATA BUS with respect to an initiator True indicates input to the initiator This signal is also used to distiguish between SELECTION and RESELECTION phase MSG MESSAGE signal driven by a target during the MESSAGE phase REQ REQUEST signal driven
143. of 4 Otherwise CHECK CONDITION status will be returned and SENSE KEY is set to ILLEGAL REQUEST The Endorser Descriptors Table 3 76 consist of 4 bytes data and are sent during DATA OUT phase in ENDORSER command If one or more Endorser Data are required Endorser Descriptor is repeated 3 92 M 3099GX GH OEM M anual Table 3 76 Endorser Descriptors Bit 7 6 5 4 3 2 0 Byte 0 Endorser Data Identifier 1 STOP BACK Reserved 2 MSB Initial Count 3 158 Endorser Data Identifier 00h The Endorser Data Identifier specifies a Endorser Data previously sent in SEND command Endorser Data Identifiers 00h to FEh are specifiable If FFh is specified all of the registered Endorser Data are selected This scanner supports 00h only STOP STOP bit of zero specifies that specified Endorser Data Identifier Ob Start 1b Stop should start printing STOP bit of one indicates that specified Endorser Data stop printing BACK Ib back side BACK bit of zero indicates that specified Endorser Data is applied to front side of the page BACK bit of one indicates that specified Endorser Data is applied to back side of the page Initial Counts 0000h to FFFFh 0 to 65535 Initial Counts specifies initial value of Endorser Data counter The endorser counter is 16bit length Signed or unsigned is defined by Endorser String One Endorser Data could have one endorser counter Ove
144. one If OFF is displayed warming up will finish within 30 sec necessarily W hen the heater is broken please set OFF The ON or OFF status flips each time you press M ode 1 T he status will be set in EEPROM automatically 63 f you want to return to Screen 36 press M ode 2 When you close the setup mode to M 3099GX GH OEM M anual SETUP MODE 14 M 3099GX GH M anual APPENDIX SEPARATION PRESSURE ADJ USTM ENT Adjust the separation pressure as follows WARNING Wait at least 3 minutes after turning off the power before replacement ACHTUNG Warten Sie mindestens 3 Minuten nach Ausschalten bevor Sie mit dem Austausch beginnen Upper transport unit Operator panel T g h h urn power Switch Make sure that the hopper table is at the bottom 2 Open the upper transport unit See page 4 2 3 Disconnect the two relay connectors on the roller ASY SEPARATION PRESSURE 4 Push the two levers green ADJ USTMENT towards each other to dis engage with the upper locking holes and lower down the two levers until they engage with Roller ASY the two levers locking holes M 3099GX GH OEM M anual C 1 Guide plate Separation pressure adjustment lever Double feed Slip feed 5 Lift the document sensor unit and keep it at the upper position with one hand a
145. oothing filtering and noise removing Power supplies This scanner has two power supplies Their output voltages are as follows Power supply 1 45V For logic circuits 12V For video amplifiers Power supply 2 24V For lamp heater and stepping motor drive 1 10 M 3099GX GH OEM M anual SPECIFICATIONS This chapter provides general electrical environmental physical and option specifications General Table 2 1 list general scanner specifications Table 2 1 General scanner specifications Type M3099GH M3099GX Item 500 sheets hopper 1000 sheets hopper 1000 sheets hopper Sensor CCD image sensor Scanning method ADF automatic document feeder amp MF manual feeder Document MAX 216 x 356 mm A4 Letter Legal 297 x 432 mm A3 Double letter size MIN 76 63 mm 3 x 2 5 Light source Green fluorescent lamp Hopper stacker MAX 500 MAX 1000 MAX 1000 capacity 64 g m sheets sheets sheets Gray scale internal 256 steps Output video Binary Halftone 64 levels Scanning speed A4 Simplex 80 PPM 60 PPM 200dpi portrait Duplex 60 PPM 50 PPM Output density Standard 400 300 240 200dpi Horizontal scanning and vertical scanning are independent If the image processing IPC2 is installed 50 to 400 dpi Horizontal scanning and vertical scanning are independent Binarization and Standard Fixed binarization dither er
146. or message is displayed on ALARM the LCD display od If turning the power on again does not recover the scanner contact the maintenance personal 5 4 M 3099GX GH OEM M anual Table 5 2 Device and operator actions for equipment errors Continued FUSEALARM PRINT RAM ALARM PRINT TIME OUT d ALARM PRINT LCD display Scanner actions 1 Action to recover LAMP ALARM 1 The Check lamp lights Check if the lamp or LAMP ALARM 2 and an error message is heater is attached M displayed on the LCD correctly Replace HEATER ALARM 1 display lamp according to the HEATER ALARM 2 The normally scan replacement method document is ejected to If turning the power CCD UNIT the stacker and the on again does not ALARM 1 mechanism system is recover the scanner CCD UNIT stopped contact the ALARM 2 maintenance staff TEMP ALARM f turning the EEPROM ALARM RAM 6 to 9 ALARM V RAM 1 to 4 ALARM HARDWARE ALARM PROGRAM ERROR The Check lamp lights and an error message is displayed on the LCD display The FAIL signal on power on again does not recover the scanner contact the maintenance personal Check if the termi nator is installed Endorser option only seconds Common action at equipment error is the buzzer activated for 3 M 3099GX GH OEM M anual 5 5 ERROR PROCESSING AND
147. or panel Optical unit front side Automatic document Power inlet Optical unit Hopper back side Power switch Figure 1 4 Arrangement of units 1 6 M 3099GX GH OEM M anual Operation Overview This section outlines the operations of the mechanism and control units of the scanner Operation of the mechanism unit The mechanism unit consists of two optical units front and back sides a hopper and ADF upper and lower transport units a motor drive system and a stacker Each optical unit consists of a CCD image sensor a lens and mirrors The hopper and ADF feeds stacked documents and the upper and lower transport units transport the documents The motor drive system drives these units The stacker stores documents When the power is turned on the lamps are lit and the scanner waits until the light intensities of the lamps become stable Once the light intensities have become stable the scanner is ready for a command from the host machine A document is picked from the hopper and then ADF feeds a document one by one The document width is checked and document top is detected The documents are counted fed and stacked on the stacker The lamps illuminate the document and a lens focuses the images on CCD for photoelectric conversion processing M 3099GX GH OEM M anual 1 7 Operation of the control unit The control unit consists of an operator panel a power supp
148. or until the reservation is superseded by another valid RESERVE UNIT command from the initiator that made the reservation or until released by a BUS DEVICE RESET message from any initiator by a hard reset condition or by a power on cycle The reservation shall not be granted if the logical unit is reserved by another initiator It shall be permissible for an initiator to reserved a logical unit that is currently reserved by that initiator If the logical unit is reserved for another initiator the target shall return RESERVATION CONFLICT status 3rdPty Ob Reserved Third Party Device ID 000b Reserved M 3099GX GH OEM M anual Superseding Reservations An initiator that currntly has a logical unit reserved may modify the current reservation by issuing another RESERVE UNIT command to the same logical unit The superseding reservation shall release the current reservation if the superseding reservation request is granted If the superseding resrvation cannot be granted because of conflicts with a previous reservation other than the current reservation then the target shall return RESERVATION CONFLICT status See ANSI SCSI 2 9 2 10 2 for details RELEASE UNIT Command The RELEASE UNIT command Table 3 9 is used to release previously reserved logical units for the requesting initiator to another specified SCSI device Table 3 9 RELEASE UNIT Command Bit Byte 7 6 5 4 3 2 1 0 Operation Cod
149. ransfer phases because they are all used to transfer data or control information via the DATA BUS The actual content of the information is beyond the scope of this section The C D I O and MSG signals are used to distinguish between the different information transfer phases see Table 3 6 The target drives these three signals and therefore controls all changes from one phase to another The initiator can request a MESSAGE OUT phase by asserting the ATN signal while the target can cause the BUS FREE phase by releasing the MSG C D I O and BSY signals The information transfer phases use one or more REQ ACK handshakes to control the information transfer Each REQ ACK handshake allows the transfer of one byte of information During the information transfer phases the BSY signal shall remain true and the SEL signal shall remain false Additionally during the inforamtion transfer phases the target shall continuously envelope the REQ ACK handshake s with the C D I O and MSG signals in such a manner that these control signals are valid for a bus settle delay before the assertion of the REQ signal of the first handshake and remain valid until after the negation of the ACK signal at the end of the handshake of the last transfer of the phase M 3099GX GH OEM M anual 3 19 Table 3 6 Information Transfer Phases Signal Phase Name Direction of Transfer Comment MSG C D 1 0 0 0 0 DATA OUT Initiator to target Dat
150. recedence over all other phases and condtions Any SCSI device may create the reset condition by asserting the RST signal for a minimum of a reset hold All SCSI devices shall release all SCSI bus signals except the RST signal within a bus clear delay of the transition of the RST signal to true The BUS FREE phase always the reset condition The effect of the reset condition on I O processes which have not completed SCSI device reservations and SCSI device operation modes is determined by whether the SCSI device has implemented the hard reset alternative or the soft reset alternative one of which shall be implemented as defined in ANSI SCSI 2 6 2 2 1 and 6 2 2 2 The hard and soft reset alternative is implemented is provided in the SftRe bit of the INQUIRY data This scanner supports Hard Reset alternative as below Hard Reset Alternative 1 Clear all I O process including queued I O process 2 Release all SCSI device reservations 3 Return any SCSI device operation modes to their appropriate initial conditions similar to those conditions that would be found after a normal power on reset MODE SELECT conditions shall be restored to their last saved values if saved values have been established MODE SELECT conditions for which no values have been save shall be returned to their default values 4 Unit attention condition shall be set Note I O process queuing in 1 and parameter saving in 3 are not supported in this scan
151. rection Table 3 66 344 Qutline ESIBEE 3 66 345 Image Emphasis 3 67 3 67 3AT MITON udin Rakion 3 67 3 48 3 68 DAD DTO M d 3 69 3 50 DIC Mode Byte 48 3 69 2 54 White Level Follower eri tad 3 70 3 52 Paper Se oceani ete i o e d e ri Perl ren e M dts 3 71 DTO Selectii cm 3 72 3 54 OBJECT POSITION Command 3 73 2 55 Posto PORCHON Eai 3 73 2 0 SEND Command 3 74 M eaa a 3 76 3 58 Gamma Function Data 3 78 3 59 SCAN Command Mn 3 79 3 60 READ Command 3 80 J61 Lype Codes Mtm 3 81 39 62 Pixel Size PREMIUM 3 83 3 63 Detected Paper Information 3 84 3 64 Job Separation S Beata event reprobo etr 3 84 3 65 Paper SIZE M 3 85 3 66 MODE SELECT 6 3 86 3 67 MODE SENSE 6 Command eee 3 87 M 3099GX GH OEM M anual Xi 3 68 Supported Mode Page Cade ip 3 88 3 69 Mode Parameter pipe uber 3 88 3 70 Mode Parameter Header 6 sene 3 89 3 71 Mode Page LOCIS
152. reset method of endorsers ase vecenrteseseseniuens B 9 Bo Reset ab endorser EDAD B 10 B311 Reset of ink B 10 B3 12 Setting SCSI ID a B 10 B313 Setting Produce 10 14 Setting picking statt time 11 Boel Setting picking HIE 12 B3 16 Setting 12 B3 17 hopper 13 D3 18 Setting heater 13 APPENDIX SEPARATION PRESSURE ADJUSTMENT _ C 1 GLOSSARY OF TERMS ecc GL 1 INDEX IN 1 viii M 3099GX GH OEM M anual Figures 6 1 6 2 6 3 6 4 6 5 6 6 A 1 200 sheets hopper 1 2 1000 sheets hopper type quede aH HEREDES Ip 1 3 Scanner block diagram 1 5 Arrangement Of Ub spalarii UN a Uie tdv eit 1 6 Control block 1 8 Dimensions of 500 sheets hopper type 2 3 Dimensions of 1000 sheets hopper type 2 4 Service QEBdS 2 5 SCSI device COnMECH ON actas cis acini cea PLU ux DR Ua 3 3 Alternative 1 termination for Single Ended Devices 3 5 Alternative 2 termination for Single Ended Devices 3 5 DATA lo we P 3 7 shite 3 26 Verify State Lest m 3 113
153. rflow and Underflow will not be detected Endorser Data is sent in SEND command to the initiator If one or more Endorser Data is specified this data structure is repeated M 3099GX GH OEM M anual 3 93 INTERFACE Table 3 77 Endorser Data Bit 7 6 5 4 3 2 1 0 Byte 0 Endorser Data Identifier 1 Reserved Reserved DECR Reserved CTSTEP 2 MSB Upper Left X EN LSB 6 MSB Upper Left Y 9 o LSB 10 Font 11 Size 12 REVS Reserved DIRS 13 Reserved 14 Reserved 15 Reserved 16 Reserved 17 Endorser String Length 18 Endorser Strings pow eue TEM DECR Ob CTSTEP add DECR bit of zero specifies CTSTEP value is added to endorser counter DECR bit of one specifies CTSTEP value is subtracted from endorser counter CTSTEP 00b no change 015 10b 11b is checked CTSTEP field specifies value to be added to or to be subtracted from endorser counter after printing 1 and 2 are available If 0 is specified no increment decrement executed 3 94 M 3099GX GH OEM M anual Upper Left X 00000000h Upper Left X field specifies X coordinate of upper left corner of endorser strings rectangle in 1 1200 inch This field applies signed long integer This scanner cannot specify Upper Left X coordinate of print position The 00000000h is regarded as default INTERFACE Upper Left Y Upper Left Y field specifies Y coordinate of upper left co
154. rner of endorser strings rectangle to be printed in 1 1200 inch This field applies signed long integer This scanner does not check validity in this field The base point of endorser string is Upper Left likewise SET WINDOW Location of Endorser Strings is different from printer strings This specifies upper left corner of the rectangle Font OOh default Font field specifies character fonts to be printed One Endorser Data could have one font Table 3 78 Font Value Description 00h Default Olhto7Fh Reserved 80h to FFh_ Downloaded Size OOh default Size field specifies character size to be printed in dots One Endorser Data could have one size available This field specifies character height in dots If zero is specified default is used REVS Ob REVS bit specifies Endorser String is reversed The Endorser String is printed from last character This scanner does not support this bit M 3099GX GH OEM M anual 3 95 DIRS 01b Table 3 79 DIRS field specifies direction of Endorser String This scanner supports 01b only Table 3 79 DIRS Value Description 00b Left to Right 01b Upper to Lower 10b Right to Left 11b Lower to Upper Endorser String Length net 20 9696 is considered as 1 character Endorser String Length field specifies length of Endorser String to be followed in bytes The Endorser String Length field forms pascal string in conjunction with
155. rollers 8 5 Index Cleaning the sensors 8 7 Cleaning the transport paths 8 6 Cleaning Tools 8 2 Closing the Upper Transport Unit 4 2 nm COMMAND COMPLETE Init lt Targ 3 103 COMMAND Phase 3 22 ABORT Init gt Targ 3 102 Command Sequence 3 110 Abrasion counter 4 6 B 2 B 6 Commands 3 27 ARBITRATION Phase 3 16 Configuration 1 5 Arbitration Delay 3 12 Configuration of the scanner 1 5 Areas that must not be perforated 6 4 Consumables 7 1 Arrangement ofunits 1 6 CONSUMABLES AND ACCESSORIES 7 1 Assertion period 3 12 Control circuit MPU 1 8 Asynchronous Information Transfer 3 20 Control unit 1 6 Attention Condition 3 24 Automatic document feeder ADF 1 1 1 6 D DATA IN Phase 3 23 DATA OUT Phase 3 23 BASIC OPERATION 4 1 Data Phase 3 22 Basic Scanning Sequence Simplex Mode 3 115 Data Release Delay 3 13 Belt Replacement 4 19 Deskew Delay 3 13 Binarization and halftone function 2 1 Device and Operator Actions for Equipment Buttons 4 7 Errors 5 4 Bus Clear Delay 3 12 Device and Operator Actions for Temporary BUS DEVICE RESET Init Targ 3 103 Errors 5 1 Bus Free Delay 3 12 DISCONNECT Init lt Targ 3 103 BUS FREE Phase 3 15 Disconnection Delay 3 13 Bus Set Delay 3 12 Document detection sensor 8 8 Bus Settle Delay 3 13 Document Limitations 6 4 Buzzer B 2 B 4 Document Quality 6 2 Document Size 2 1 6 1 g DOCUMENT SPECIFICATION 6 1 p Document type 6 2 6 8 Cable Skew Delay 3 13 Document width detection sensor 8 7 charge coupled d
156. ror diffusion halftone function method If the image processing II IPC2 is installed Automatic separation image emphasis outline extraction mirror image inversion simplified DTC Dynamic threshold smoothing filtering nois removing Interface SCSI 2 M 3099GX GH OEM M anual 2 1 Electrical Table 2 2 lists electrical specifications Specifications 2 Table 22 Electrical specifications Item Specification Input power Voltage 100 to 120 VAC 220 to 240 VAC 10 Phase Single phase Frequency 50 60 Hz 2 490 Power consumption 0 25 kVA or less Rush current 30 A or less Momentary power failure 100 0 5 Hz Leakage current 3 5 mA or less Dielectric strength DC 1 8 KV for one minute or more between FG and AC lines AC line noise Voltage 1 2 KV pulse duration 5 is Heat capacity 110 Kcal H 440 BTU H Environmental Table 2 3 lists environmental specifications Specifications m Table 23 Environmental specifications Item Specification Ambient Device status Operating Not operating conditions Temperature 5 to 35 C 20 to 60 C Humidity 20 to 80 8 to 9596 no condensation no condensation Shock 0 2 G less 0 4 G or less Stability 5 or less 10 or less Acoustic noise 59 dBA or less 50 dBA or less ISO 7779 ISO 7779 ESD 8 KV or more 2 2 M 3099GX GH OEM M anual Physical Figure 2 1 to Figure 2 2
157. rtrait After ejecting paper by OBJECT POSITION command Unload Object orientation and paper size are detected 3 This bit is valid only after OBJECT POSITION Load Object Unload Object is completed M 3099GX GH OEM M anual 3 85 INTERFACE MODE SELECT 6 Command The MODE SELECT 6 command Table 3 66 provides a means for the initiator to specify medium logical unit or peripheral device parameters to the target Targets that implement the MODE SELECT command shall also implement the MODE SENSE command Initiators should issue MODE SENSE prior to each MODE SELECT to determine supported pages page lengths and other parameters Table 3 66 MODE SELECT 6 Command Bit 7 6 5 4 3 2 1 0 Byte 0 Operation Code 15h 1 Logical Unit Number Reserved SP 2 Reserved 3 Reserved 4 Parameter List Length 5 Control If an initiator sends a MODE SELECT command that changes any parameters that apply to other initiators the target shall generate a unit attention condition for all initiators except the one that issued the MODE SELECT command see ANSI SCSI 2 7 9 The target shall set the additional sense code to MODE PARAMETERS CHANGED PF Page Format 1b SCSI 2 format SP Save Pages Ob not save pages Parameter List Length 12 Lamp timer 12 Job separation sheet This field specifies the length in bytes of the mode parameter list that shall be transferred from the
158. s configuration and components of the scanner Configuration of the scanner This scanner can be divided into two major sections mechanism and control unit The mechanism unit consists of a hopper to load documents automatic document feeder upper and lower transport units to transport documents a motor drive system and an optical unit The control unit consists of an operator panel a power supply a mechanism driver to drive and control the mechanism unit an image processing control and an interface control Figure 1 3 shows scanner configuration Mechanism unit Front side Back side Front side Back side Printer Optical Optical Transfer Sensor Lamp Lamp system heater heater system system inverter inverter CCD CCD driver driver Video Video circuit circuit Sensor board Control unit Mechanism driver Motherboard Operator Back side IPC 2 Extend Interface Power supply panel reading memory board 5V 12V board board Front side IPC 2 Extend Power supply Back side memory 24v T i Option SCSI 2 100 200VAC Figure 1 3 Scanner block diagram M 3099GX GH OEM M anual 1 5 Arrangement of units Figure 1 4 shows arrangement of these units Power supply units Operat
159. s mode is used when the batch of paper which length are same are scanned When the paper which tears and wrincled are scanned Scanner may mistake it also This mode is used when the batch of paper which length and thickness are same are scanned However when the thin papers are scanned Scanner may mistake to detect the Double feed rarely In case of this please test to scan the thin papers in advance B3 2 Setting IPC 2 pre set mode When you set the using of IPC 2 pre set mode you must set as follows IPC 2 SET lt lt SETUP MODE gt gt Screen 2 press Mode 1 twice to go to 57 the IPC 2 SET screen Screen 8 Screen 8 Press Mode 2 to see Screen 9 or 10 If No is displayed IPC 2 pre set mode is not used IPC 2 SET If pattern number 1 5 is displayed IPC 2 pre set mode is used No or number status flips each time you press Mode 1 Screen 9 The default setting is IPC 2 SET 2f you press the Mode 2 at Screen 9 you LL EE return to Screen 8 The setting is stored to EEPROM If you press the Mode 2 at Screen 10 Screen 10 you go to Screen 12 B 4 M 3099GX GH M anual Panel Host Set Ignore 43 If you press the Mode 1 at Screen 12 IPC 2 pre set mode be not used Also the setting No Model Yes Mode 2 is changed to No obligatory and stored to Screen 11 EEPROM If
160. s of READ command sequence is 4 9 5 Feed out document from ADF This command is omissible because end of scanning automatically feeds out document Release exclusive use of the scanner 1 Thisloop is used to scan a batch of document 2 Thisloop is used to scan a batch of identical format document at maximum speed M 3099GX GH OEM M anual 3 115 Duplex Scanning The duplex scanning is extension of simplex mode scanning For duplex scanning SET WINDOW command must specify front side window window identifier 00h and back side window window identifier 80h in window descriptor SCAN command is required to invoke duplex mode scanning by sending window identifier 00h 80h in data out phase READ command is issued to read image data sequentially front window and back window In the READ command window identifier field must be specified in data type qualifier field to distinguish which side of window data is read When front image data is completely read back image data can be read in this scanner RESERVE UNIT Reserve exclusive use ofthe scanner Y Specify window parameters for front side 00h and back SET WINDOW ID 00h 80h side 80h The window parameters must be sent in one SET WINDOW command SEND Send Halftone M ask and or Gamma Function data if required Feed document into ADF This command is omissible because SCAN or READ command automatically feeds in ECT POSITION
161. sert the lamp unit completely Then turn the thumb screw completely to avoid cover open error 9 Attach the side cover Thumb screw Lamp unit Roller ASY Replace the roller ASY as follows Replacement WARNING W ait at least 3 minutes after turning off the power before replacement Upper transport unit Operator panel D Turn off the power switch 2 O pen the upper transport _ unit See page 4 2 4 16 M 3099GX GH M anual Lever green 8 Disconnect the two relay connectors on the roller ASY front 3 pin back 2pin 4 Push the two levers green towards each other to dis engage with the upper locking holes and lower down the two levers until BASIC Roller ASY they engage with the two OPERATION levers locking holes Document sensor unit 5 Lift the document sensor unit and keep it at the upper position with one hand and pull the roller ASY out with the other hand 6 Install a new roller ASY and return the document sensor unit to its original position Roller ASY Lever green 7 Push the two levers green towards each other to dis engage with the lower locking holes and lift them up until they engage with the two upper locking holes Connect the two relay connectors on the roller Roller ASY ASY front 3 pin back 2 pin 9 Close the upper transport unit See page 4 2 M 3099GX GH OEM M anual 4 17 Pick Rol
162. show the scanner dimensions Figure 2 3 Specifications shows scanner service areas Table 2 4 lists physical specifications SPECIFICATIONS 610 470 Unit mm Figure 2 1 Dimensions of 500 sheets hopper type M 3099GX GH OEM M anual 2 3 610 680 Unit mm Figure 2 2 Dimensions of 1000 sheets hopper type 2 4 M 3099GX GH OEM M anual Table 2 4 Physical specifications Figure 2 3 Service areas Type I 500 sheets hopper type 1000 sheets hopper type em Dimensions Width 610 mm 610 mm Depth 680 mm 680 mm Height 470 mm 530 mm Weight 55kg 65kg 7K 8 Scanner m 8 d T F 8 Y y 200 610 le 600 1 390 Front K Unit mm M 3099GX GH OEM M anual 2 5 SPECIFICATIONS Option Specifications Table 2 5 lists the scanner option specifications Table 2 5 Option specifications Item Specification Detail Remark Endorser CA01023 D004 Ink jet back side print max 20 characters 2 6 M 3099GX GH OEM M anual INTERFACE INTERFACE The M3099G image scanner provides SCSI 2 Small Computer System Interface 2 interface The SCSI 2 is a 8 bit parallel interface standardized by ANSI American National Standard Institute This chapter provides an overview of the SCSI and interface specification of this sc
163. sor 3 Close the upper transport unit See page 4 2 M 3099GX GH OEM M anual 8 9 M 3099GX GH M anual APPENDIX ENDORSER M Specifications Table A 1 lists the endorser specifications Table A 1 Endorser specifications Item Specification Printing method Ink jet printing method Characters Alphabet to Z a to z Number 0 1 to 9 Symbol 96 amp lt gt e Y blank Maximum number 20 of characters Character size 2 9 x 1 5 mm 0 11 x 0 06 hight x width Character pitch Approx 2 54 mm 0 1 Print area Back side of the document gt 5 mm 0 2 gt 28 mm 1 17 ENDORSER C gt 20 mm 0 79 D 5 mm 0 2 Center of the Read reference osition document y Bi Y c Es y 5 Back Figure A 1 Print area M 3099GX GH OEM M anual A 1 A2 Panel By the operator panel you can set following conditions Other operation conditions such as print offset print characters can be set by the host machine A2 1 How to setthe endorser ON or OFF When you use the endorser you must set the endorser ON as follows lt lt SETUP MODE gt gt CD While pressing the Mode 1 turn on the pre neoni eer aea power of the scanner Then the LCD displays the SETUP MODE initial Screen 1 screen Screen 1 2 Press Mode 1 eight times to go to the lt
164. ssue the command again at a later time see ANSI SCSI 2 7 6 3 98 M 3099GX GH OEM M anual Message See The message system allows communication between an initiator and ANSI SCSI 2 6 5 target for the purpose of interface management A message may be one two or multiple bytes in length One or more messages may be sent during a single MESSAGE phase but a message may not be split over MESSAGE phase The initiator is required to end the MESSAGE OUT phase by negating ATN when it sends certain messages identified in Table 3 82 One byte Two byte and extended message formats are defined The first byte of the message determines the format as defined in Table 3 82 Table 3 82 Message Format Value Message Format 00h One Byte Message COMMAND COMPLETE Olh Extended Messages 02h to 1Fh One Byte Messages 20h to 2Fh Two Byte Messages not used 30h to 7Fh Reserved 80h to One Byte Messages IDENTIFY M 3099GX GH OEM M anual 3 99 One byte messages consist of a single byte transferred during MESSAGE phase The value of the byte determines which message is to be performed as defined in Table 3 83 See ANSI SCSI 2 6 6 Table 10 The implemented Message Codes by this scanner is Table 3 83 Table 3 83 Message Codes Code Support Message Name Direction Nefate Before last Init Targ ACK 00h M M COMMA
165. st byte Reserved See ANSI SCSI 2 7 1 1 Reserved bits fields bytes and code values are set aside for future standardization Their use and interpretation may be specified by future extensions to ANSI SCSI standard A reserved bit field or byte shall be set to zero or in accordance with a future extension to this standard A target that receives a reserved bit field or byte that is not zero or receives a reserved code value shall terminate the command with CHECK CONDITION status and the sense key shall be set to ILLEGAL REQUEST Logical Unit Number The logical unit number is defined in the IDENTIFY message The target shall ignore the logical unit number specified within the command descriptor block if an IDENTIFY message was received This scanner supports Logical Unit Number 000b only Followings shows target s response to selection of invalid logical unit In response to an INQUIRY command the target shall return the INQUIRY data with the peripheral qualifier set to the value required In response to any other command except REQUEST SENSE the target shall terminate the command with CHECK CONDITION status In response to an REQUEST SENSE command the target shall return sense data The sense key shall be set to ILLEGAL REQUEST and the additional sense code shall be set to LOGICAL UNIT NOT SUPPORTED M 3099GX GH M anual 3 27 INTERFACE Transfer Length The transfer length field specifies the amount of data
166. t sensor unit and keep it at the upper position with one hand and pull the roller ASY out with the other hand 6 Move the guide on the hopper table completely to the end M 3099GX GH OEM M anual 4 19 7 H old both ends of the guide plate and press them down to remove the guide Pull out the belt ASY Belt ASY Separate the belt roller and shaft from the guide plate Guide plate 10 D etach the belt from the roller Roller Belt ASY Bracket M ount a new belt by following step 7 to 0 in reverse Align the bracket on the shaft as shown in the figure 42 the document sensor unit and keep it at the upper position with one hand and pull the roller ASY out with the other hand Close the document sensor unit downward 4 20 M 3099GX GH M anual 14 Push the two levers green towards each other to dis engage with the lower locking holes and lift them up until they engage with the two upper locking holes 15 Connect the two relay connectors on the roller BASIC ASY OPERATION 16 Close the upper transport unit See page 4 2 Pad Replacement Replace the pad as follows dis WARNING Wait at least 3 minutes after turning off the power before replacement Upper transport nit Operator panel Turn off the power switch Make sure that the hopper table is at the bottom 2 Open the upper transport unit See page B 2 Power switch
167. t unit Cleaning the steel rollers with cleaner F2 This cleaning is required when the toner stick to the roller 1 O pen the upper transport unit See page 4 2 2 Apply a small amount of cleaner F2 to a Q Tips W hileturning the roller slowly wipe its surface with Q Tips Feed roller Cleaning the transport paths Clean the transport paths as follows T O pen the upper transport This roller exists only 1000 sheets unit See page 4 2 HERRE GRA 2 Wipe the transport paths with a dry cloth or cloth soaked in isopropyl alcohol U sea vacuum cleaner when paths removing paper dust from the paths 3 Closethe upper transport unit See page 4 2 8 6 M 3099GX GH M anual Cleaning glass surface Clean the glass surface of the sheet guide assembly as follows Glass Open the upper transport unit See page 4 2 2 Lift the sheet guide assembly by holding the Sheet guide assembly handles on both ends and pull it out of the machine 3 Wipe the glass surface on both sides with a dry cloth or cloth soaked in isopropyl alcohol 4 Re install the sheet guide assembly 5 Close the upper transport unit See page 4 2 Cleaning the sensors Document w idth detection sensor Clean the four document width detection sensors as follows Document sensor unit 1 Open the upper transport unit See page 4 2 2 Hold the handles of the
168. tOfL 2 Reserved MSB Parameter List Length 4 LSB 5 Control PF Page Format Ob ignored SelfTest Self Test 1b SelfTest This bit is of one directs the target to complete its default selftest If the selftest successfully passes the command shall be terminated with GOOD status otherwise the command shall be terminated with CHECK CONDITION status and the sense key shall be set to HARDWARE ERROR DevOfL Device Off Line Ob ignored UnitOfL Unit Off Line Ob ignored Parameter List Length 0000h not supported M 3099GX GH OEM M anual 3 55 SET WINDOW Command The SET WINDOW command provides a means for the initiator to specify one or more windows within the scanning range of the device This duplex scanner supports one window for each front and back page Table 3 32 SET WINDOW Command Bit 7 6 5 4 3 2 1 0 Byte 0 Operation Code 24h 1 Logical Unit Number Reserved 2 Reserved 3 Reserved 4 Reserved 5 Reserved 6 MSB Ed Transfer Length EUN Ps LSB 9 Control The transfer length specifies the length in bytes of the data that shall be sent during the DATA OUT phase A transfer length of zero indicates that no window parameters data shall be transferred This condition shall not be considered as an error The window parameters data shall consist of a header followed by one or more window descriptors Each window descriptor specifi
169. te s n M 3099GX GH OEM M anual Window Identifier OOh front side or 80h back side The window identifier specifies the window defined by the window descriptor window is referenced by the window identifier during data transfers and parameter updates Fujitsu defines for duplex scanner window identifiers 00h to 7Fh are used for front page and 80h to FFh are used for back page INTERFACE implicitly This scanner supports one window for each side therefore window identifier 00h for front page and window identifier 80h for back page Auto Ob Reserved X Axis Resolution 0 400dpi 200 240 300 400 dpi without IPC2 0 400dpi 50 to 400dpi at 1dpi step with IPC2 The x axis resolution field specifies the resolution in the scan line directionThe unit of measure is picture elements pixels per inch A value of zero specifies the default resolution Y Axis Resolution 0 400dpi 200 240 300 400 dpi without IPC2 0 400dpi 50 to 400dpi at 1dpi step with IPC2 The y axis resolution field specifies the resolution in the base line direction The unit of measure is picture elements pixels per inch A value of zero specifies the default resolution X Axis Upper Left 0 to 14592 1 1200 inch for M3099GX 0 to 10368 1 1200 inch for M3099GH The x axis upper left field specifies the x axis coordinate of the upper left corner of the window This coordinate is measured from the scan line using the target s c
170. ter 6 Document Specification Chapter 7 Consumables and Accessories Chapter 8 Cleaning Appendix A Endorser Appendix B Setup Mode Appendix C Separation Pressure Adjustment Glossary of Terms Index SPECIFICATIONS INTERFACE BASIC OPERATION ERROR PROCESSING AND RECOVERY DOCUMENT SPECIFICATION CONSUMABLES ACCESSORIES ENDORSER SETUP MODE SEPARATION PRESSURE ADJUSTMENT GLOSSARY OF TERMS Scanner Types OVERVIEW This chapter provides scanner features configuration and operation The M3099GX GH is a very fast and highly functional image scanner developed for volume filing using charge coupled device CCD image sensors This scanner featuring duplex reading and high quality image processing read documents fed by an automatic document feeder ADF Scanner types of M3099GH and M3099GX are shown in Table 1 1 and 1 2 Those types of the scanner is hereinafter referred to as this scanner Table 1 1 Types of M3099GH Type 500 sheets hopper 1000 sheets hopper with IPC2 with IPC2 Item 100V 200V 100V 200V A4 Letter Legal document size Scanning Simplex 80 PPM A4 200dpi portate Duplex 60 PPM A4 200dpi portrate Hopper capacity 500 sheets 1000 sheets de du IPC2 option Installed Installed Input voltage 100V 200V 100V 200V Appearance Figure 1 1 Figure 1 2 M 3099GX GH OEM M
171. u want to change blinks T hen press M ode Screen 29 2 until the digit changes as you want T he specifiable range 15 from 0 2 to 29 8 sec in 0 2 sec step SETUP MODE 44 P ress M ode 1 and M ode 2 at a time to see Screen 28 T he settings are stored to EEPROM 45 w hen you close the setup mode go to 9 M 3099GX GH OEM M anual 11 B3 15 Setting picking time When you set the picking time you must set as follows lt lt SETUP MODE gt gt PICK TIMER Screen 30 lt lt SETUP MODE gt gt Screen 31 At Screen 2 press Mode 1 fifteen times to go to the PICK TIMER screen Screen 30 Press Mode 2 to see Screen 31 The default setting is 2 sec At Screen 31 press Mode 1 until the digit you want to change blinks Then press Mode 2 until the digit changes as you want The specifiable range is from 0 5 to 99 5 sec in 0 5 sec step Press Mode 1 and Mode 2 at a time to see Screen 30 The settings are stored to EEPROM 69 When you close the setup mode go to 9 B3 16 Setting time out limit When you set the time out limit you must set as follows SETUP MODE TIME OUT SET Screen 32 TIME OUT SET Screen 33 6 At Screen 2 press Mode 1 sixteen times to go to the TIME OUT SET screen Screen 32 62 Press Mode 2 to see Screen 33 The default setting is 30 sec 63 At Screen 33 press Mode 1 u
172. uo een ederet enia 1 6 Operation Over Views ccr roc tonne rae eR 1 7 Operation of the mechanism unit 1 7 Operation cansa 1 8 Resolutio executed hates cana OR 1 9 CHAPTER 2 SPEUIFIGATIONS 2 1 era oer eder 2 1 Electrical Specifications 2 2 Environmental cultura dE 2 2 Physical 2 3 2 6 CHAPTER 3 INTERFACE erc 3 1 Physical SpecificatiofiS 3 3 SCSI Bus See ANSI SGSI 2 45 5 3 7 SCSI Bus Signals See ANSI SCSI 2 4 6 3 8 Signal Pii c 3 9 SO rCE 3 9 SCSI Bus 3 11 rbitr tion Delay dicato nativo e t add mela uiu 3 12 Assertion ki cb bue cx Roe 3 12 Bt deat 3 12 Bus Free Delay 3 12 Bus Set Delay aiino eee o em a OR 3 12 Bus Settle Delay pri os qx ro ii dad 3 13 Cable Sbewr Ca acacia toe ctae anaa 3 13 M 3099GX GH OEM M anual iii 3 13 Deskew Delay 3 13 Disconnection Delay ete renes 3 13 Fold 3 13 ra Cassa ON ue Econ putet ad 3 13 Power On to Selection Time eee 3 14 Reset to Selection Time
173. urrent measurement unit divisor Y Axis Upper Left 0 to 20736 1 1200 inch The y axis upper left field specifies the y axis coordinate of the upper left corner of the window This coordinate is measured from the base line using the target s current measurement unit divisor Window Width 0 to 14592 1 1200 inch for M3099GX 0 to 10368 1 1200 inch for M3099GH M 3099GX GH OEM M anual 3 59 The window width field specifies the width of window in scan line direction The window width is measured using the target s current measurement unit divisor Window Length 0 to 20736 1 1200 inch The window length field specifies the length of the window in the base line direction The window length is measured using the target s current measurement unit divisor Note The relation between X Axis Resolution Y Axis Resolution X Axis Upper Left Y Axis Upper Left Window Width Window Length Upper Left X field value ULX Upper Left Y field value ULY Width field value W Length field value L X Resolution XR Y Resolution YR 1 Maximum Scanning Area limitations 0 lt ULX W 14592 1 1200 inch for M3099GX 10368 1 1200 inch for M3099GH 0 lt ULY L lt 20736 1 1200 inch 2 Width and X Resolution limitation 9 XRxW 1200 lt 4864 dot for M3099GX 3456 dot for M3099GH 3 Length and Y Resolution limitation 1 YRXL 1200 lt 6912 line 4 Horizontal and Vertical limitation M3099GX only if 13200 1
174. ved 29 Reserved 30 Reserved 31 Reserved M 3099GX GH OEM Manual 3 43 INTERFACE Implemented Vendor Specific Command CXh 0000h DXh 0000h EXh 0000h FXh 0000h without ENDORSER CXh 0002h DXh 0000h EXh 0000h FXh 0000h with ENDORSER Implemented Vendor Specific Command field indicates vendor specific command implemented by the scanner This field consists of sets of 2 bytes structure as Table 3 19 Each bit position in these fields indicates lower 4 bits of the command code Implemented Vendor Specific Command field is subdivided to CXh DXh EXh FXh as Table 3 20 Table 3 19 2 bytes structure Bit 7 6 5 4 3 2 1 0 Byte 0 bit 15 bit 14 bit 13 bit 12 bit 11 bit 10 bit9 bit 8 1 bit7 bit6 bit5 bit4 bit3 bit2 bitO Table 3 20 Implemented Vendor Specific Command Bytes Description 42 43 Vendor Specific Command field CXh 44 45 Vendor Specific Command field 46 47 Vendor Specific Command field EXh 48 49 Vendor Specific Command field FXh Table 321 Implemented Vendor Specific Command Field amp Bit Command Code CXh 0 SET SUBWINDOW COh V 1 ENDORSER Clh V DXh EXh FXh 3 44 M 3099GX GH OEM M anual Vendor Unique Parameter See Table 3 22 Vendor Unique Parameter field indicates supported Ven
175. w to set the print number reset condition If you want to return to the initial status to read You can choose whether to reset or not when HOPPER EMPTY is detected lt lt SETUP MODE gt gt ENDORSER RESET METHOD Screen 7 HOP EMPTY RESET Screen 8 ENDORSER RESET METHOD screen Screen 7 9 Press Mode 2 to see Screen 8 If ON is displayed the print number will be reset when HOPPER EMPTY is detected If OFF is displayed it wouldn t The ON or OFF status flips each time you press Mode 1 The status will be set in EEPROM automatically 2 If you want to close the job go to A2 How to reset the print number manually You can reset the print number to the initial number by operator panel as follows SETUP MODE ENDORSER RESET Screen 9 Screen 1 press Mode 1 ten times to go to the ENDORSER RESET screen Screen 9 Screen 1 press Mode 1 nine times to go to the 0 If you want to return to Screen 7 press Mode 3099 OEM M anual A 3 ENDORSER RESET VALUE 00001 No Mode 1 Yes Mode 2 Screen 10 RESET Finish 00001 Screen 11 2 Press Mode 2 to see Screen 10 You may see current print number If you want to reset the number press Mode 2 And you can see Screen 11 for 3 sec If you don t want it press Mode 1 to go to Screen 9 If you want to close the job go to
176. wing standards Maximum 0 14 or less Average 0 1 or less M 3099GX GH OEM M anual 6 7 Job Separation Sheet Shape The following Figure 6 6 shows the basic of the document pus Scanning direction ua Center of document Unit mm more than 210 mm Figure 6 6 Shape of document Document type The document type and ream weight specifications given in page 6 2 However the document size shall be A4 or larger 210 mm or more wider 6 8 M 3099GX GH OEM M anual CONSUMABLES AND ACCESSORIES This chapter provides consumables and accessories of the scanner Consumables some spare parts in stock The abrasion counter can be used to check the number of scanned documents See page 4 6 Table 7 1 Consumables Table 7 1 lists consumables used for the scanner Be sure to keep Specification Remark Lamp CA02950 0548 Up to 500 hours or more Two lamps per scanner Pick roller CA01023 F242 Up to 300 000 sheets or one year Requires two per scanner Roller ASY CA02869 F230 Up to 600 000 sheets or one year This part contains Pick Roller but the life of the Roller Units does not include the life of the Pick Roller Belt CA02869 Y218 Up to 300 000 sheets or one year Belt ASY CA02869 F220 Up to 600 000 sheets or one year This part includes Separation Belt but the life of the Belt Assembly does not include the life of the Separat
177. xxxb Standard Paper bits 4 to 0 enable 11xxxxxxb Non Standard Paper Paper Width X Paper Length Y effective xx0xxxxxb Image Transfer Top to Bottom xxlxxxxxb Reserved xxxOxxxxb Orientation Portrait xxxlxxxxb Landscape xxxx0000b Standard Paper Size Undefined xxxx0001b Undefined xxxx0010b Undefined xxxx0011b A3 M3099GX Undefined M3099GH xxxx0100b A4 xxxx0101b AS xxxx0110b 11 x17 M3099GX Undefined M3099GH xxxx0111b 8 5 11 xxxx1000b Undefined xxxx1001b Undefined xxxx1010b Undefined xxxx1011b Undefined xxxx1100b B4 M3099GX Undefined M3099GH 1101 5 xxxx1110b Undefined xxxx1111b 8 5 x14 M 3099GX GH OEM M anual 3 71 INTERFACE Paper Width X The paper width x field specifies paper width in 1 1200 inch when paper size was specified as non standard paper Paper Length Y This field specifies paper length in 1 1200 inch when Paper Size was specified as Non Standard Paper Notes 1 If the ADF is used and this parameter is not specified the paper is scanned as default paper size A3 for M3099GX or A4 for M3099GH 2 This Paper Size is assuming the document which will be fed through ADF The window area specified in window descriptor block Upper Left X Upper Left Y Width Length must be equal or less than specified paper size 3 The Fujitsu Image Scanners calculate window origin from ADF center therefore if Paper Si
178. xxxxx011b xxxxx100b xxxxx101b Dark xxxxx110b Dark for Scanner xxxxx111b Light Table 3 50 DTC Mode Byte 48 value bit Description 000xxxxxb Noise Removing Enable 001xxxxxb Disable 0 matrix size 5 5 Disable 00x1xxxxb Enable 00xx1xxxb 4x4 Disable 00xx0xxxb Enable O0xxxlxxb 3x3 Disable 00xxx0xxb Enable O0xxxxlxb 2x2 Disable 00xxxx0xb Enable O0xxxxxlb Equal to Threshold Black White M 3099GX GH OEM M anual 3 69 INTERFACE White Level Follower 00h 80h COh The white level follower field specifies white level follower operation Table 3 51 White Level Follower value Description 00h Default Depends on IMAGE COMPOSITION IMAGE COMPOSITION 00h Enable 016 Disable Olh to 7Fh Reserved 80h Enable 816 to Reserved COh Disable Reserved Barcode Window List Subwindow List 00000000b Reserved 00000000b Reserved 3 70 M 3099GX GH OEM M anual Paper Size The paper size field specifies paper size which would be fed through ADF If 00h is specified in this field these functions are disabled Table 3 52 Paper Size Value Description OO0xxxxxxb Undefined O1lxxxxxxb Undefined 10xxx
179. y 250 ms recommended Transfer Period set during an SDTR message M 3099GX GH OEM M anual 3 11 Arbitration Delay The minimum time an SCSI device shall wait from asserting BSY for arbitration until the DATA BUS can be examined to see if arbitration has been won There is no maximum time Assertion period The minimum time that a target shall assert REQ or REQB while using synchronous data transfers Also the minimum time that an initiator shall assert ACK or ACKB while using synchronous data transfers REQB and ACKB timings only apply to optional wide data transfers Bus Clear Delay The maximum time for an SCSI device to stop driving all bus signals after The BUS FREE phase is detected SEL is received from another SCSI device during the ARBITRATION phase The transition of RST to true For the first condition above the maximum time for an SCSI device to clear the bus is 1200 nanoseconds from BSY and SEL first becoming both false If an SCSI device requires more than a bus settle delay to detect BUS FREE phase it shall clear the bus within a bus clear delay minus the excess time Bus Free Delay The minimum time that an SCSI device shall wait from its detection of the BUS FREE phase until its assertion of BSY when going to the ARBITRATION phase Bus Set Delay The maximum time for an SCSI device to assert BSY and its SCSI ID bit the DATA BUS after it detects BUS FREE phase for the
180. y other I O process for the same I T x nexus Sense data shall be cleared upon receipt of any subsequent I O process including REQUEST SENSE to the same I T x nexus The sense data format for error code 70h current errors is supported M 3099GX GH OEM M anual 3 49 INTERFACE Table 3 28 Sense Data Format Bit 7 6 5 4 3 2 1 0 Byte 0 Valid Error Code 70h 1 Segment Number 2 Filemak EOM ILI Reserved Sense key 3 MSB Information lel LSB 7 Additional Sense Length 8 MSB Command Specific Information lul LSB 12 Additional Sense Code 13 Additional Sense Code Qualifier 14 Field Replaceable Unit Code 15 SKSV Sense Key Specific 17 Valid Ib Valid Information Segment Number 00h not supported Filemark Ob Reserved EOM End of Medium This bit of 1 indicates end of reading a window ILI Incorrect Length Indicator This scanner use this bit when total read image data is not equal to defined window data M 3099GX GH OEM M anual The sense key additional sense code and additional sense code qualifier provide a hierachy of information The intention of the hierarchy is to provide a top down approach for an initiator to determine information relating to the error and exception conditions The sense key provides generic categories in which error and exception condition can be reported Initiators would typical
181. ze is not specified window will be located in unexpected position Selection 00h 40h with IPC2 80h with IPC2 The selection field specifies which DTC is activated Table 3 53 DTC Selection Value Description 00000000 Default Simplified DTC with IPC2 01000000 Dynamic Threshold Circuit with IPC2 10000000b Simplified DTC with IPC2 11000000b Reserved others Reserved Notes 1 If simplified DTC is selected SDTC parameter will be referenced 2 If DTC is selected DTC mode will be referenced 3 72 M 3099GX GH OEM M anual OBJECT POSITION The OBJECT POSITION command Table 3 54 provides positioning functions Absolute as well as relative positioning is provided A target shall return CHECK CONDITION status and set the sense key to ILLEGAL REQUEST positioning function is requested that is not supported Table 3 54 OBJECT POSITION Command 7 6 5 4 3 2 1 0 Byte 0 Operation Code 31h 1 Logical Unit Number Reserved Position Function 2 MSB 3 Count 4 ESB J Reserved 6 Reserved 7 Reserved 8 Reserved 9 Control This position function field specifies the requested function see Table 3 55 Table 3 55 Position Function Position Function Description 000b Unload Object 001b Load Object others Reserved M 3099GX GH OEM M anual 3 73 Unload Object T
Download Pdf Manuals
Related Search
Related Contents
Netgear GSM7328S RXYQ - Daikin AC MANUAL DE USUARIO AD131 LSB-german 771076128 Panasonic TC-L60E55 60" Full HD SMART VIERA LED television SGN UNIT - Notices d`emploi pour chaudières, chauffe Bianco Rainsaver MK3 Installation and Operating Instructions Samsung 31,5" CURVED монитор серии 5 S32E590C Инструкция по использованию Copyright © All rights reserved.