1. EE N 1 NET4 NET3 O00 en O00 FI N Figure 69 Slot numbering for the Fibre Channel pass thru blades CAUTION e FC pass thru blades must always be installed in slot NET3 first This ensures that port A of the FC daughter cards is connected if redundant fibre channel connections are not used e If Gigabit Ethernet daughter cards are installed in the server blades LAN switch blades see page 81 or Ethernet pass thru blades see page 99 must be installed in slots NET3 and NET4 Asynchronous balanced mode of Ethernet blades and fibre channel blades in slots NET3 and NET4 is not permitted PRIMERGY BX600 S2 Basic Unit 117 FC Port Assignment FC Pass Thru Blade Each FC pass thru blade has ten front slots for SFP modules via which the Fibre Channel connections to the server blades are established The SFP modules are assigned to the server blades according to the numbering of the slots see figure 70 and figure 71 Figure 71 Slot numbering for the server blades 118 PRIMERGY BX600 S2 Basic Unit FC Pass Thru Blade FC Port Assignment In the following the assignment of the Fibre Channel ports is shown using configuration examples Configuration with Ten 2 way Server Blades The following figure
2. 5 4 3 Updating the Switch Blade Firmware Before you update the firmware you must allocate IP addresses to the individual switch blades Proceed as follows gt Switch on the basic unit and start the management console Telnet of the management blade Console Menu page_root 1 Management Agent 2 Emergency Management Port 3 Console Redirection 4 TFTP upgrade 5 Logout 6 Reboot Management Blade 7 System Information Dump Enter Selection 3 J gt Inthe management blade console select the menu item Console Redirection Console Redirection Table page_0 1 Console Redirect Server Blade 2 Console Redirect Switch Blade 3 Set Return Hotkey Ctrl a character 0 Enter selection or type 0 to quit 2 L Inthe Console Redirection Table menu select the menu item Console Redirect Switch Blade 64 PRIMERGY BX600 S2 Basic Unit Preparation for Use and Operation Updating BX600 System Components Console Redirection Switch Blade page_3 2 1 Console Redirect Switch Blade_l 2 Console Redirect Switch Blade_2 Enter selection or type 0 to quit 1 L gt Enter the desired switch blade The command line interface session starts Press lt Ctrl Q gt Return Console Menu J L Press the Return key to switch to command mode Command mode is indicated by the prompt Consol e CLI session with the Switch Blade is opened To end the CLI session enter
3. Figure 44 Slots for the switch blades The installation of two LAN switch blades in NET1 and NET2 or NET3 and NET4 enables redundant LAN connections to be provided for the relevant LAN controllers of the server blades CAUTION e LAN switch blades must always be installed in slots NET1 and NET3 first This ensures that port A of the relevant LAN controller is connected if redundant LAN connections are not used e To provide fibre channel functionality FC pass thru blades see page 113 or FC switch blades see page 105 must be installed in slot NET3 and or slot NET4 Asynchronous balanced mode of Ethernet blades and fibre channel blades in slots NET3 and NET4 is not permitted 90 PRIMERGY BX600 S2 Basic Unit Ethernet Switch Blades Port Assignment of the LAN Switch Blades The configuration examples below show the assignment of the onboard LAN controller ports to the LAN switch blades in slots NET1 and NET2 The port assignment for the gigabit Ethernet daughter cards to the LAN switch blade ports in slots NET3 and NET4 takes place accordingly Configuration with Ten 2 way Server Blades The following figure illustrates the assignment of the switch blades to the LAN ports of the server blades in a configuration with ten 2 way server blades Switch blade 1 Switch blade 2 Server blade 8 Server blade 9 Server blade 10 Server blade 1 Server blade 2 Server blade 3 Server blade 4 Se
4. The PRIMERGY BX600 S2 basic unit can have one or two Fibre Channel pass thru blades to provide Fibre Channel functionality for the installed server blades A Fibre Channel FC pass thru blade offers 10 ports for bypass connections between FC daughter cards installed in the server blades and the optical transceivers for serial FC I O and general I O signals e Fibre Channel switch blade The FC switch blade is an alternative to the FC pass thru blade An FC switch blade provides the FC daughter cards of the server blades with up to ten internal fabric ports and up to four external fabric ports The complete Brocade Fabric OS 5 0 4 scope of supply and services is available as an operating system for the FC switch blade Management blade The PRIMERGY BX600 S2 basic unit accommodates two hot swappable redundant management blades with an integrated management solution for complete remote administration of the system PRIMERGY BX600 S2 Basic Unit 11 Features Introduction KVM Blade For administering the server blades the PRIMERGY BX600 S2 basic unit offers a KVM blade which allows the individual server blades to be connected to a console The standard KVM blade allows a monitor PS2 keyboard and PS2 mouse to be connected for local administration of the server blades The adv KVM blade offers the same functionality as the standard version of the KVM blade plus a LAN port for connecting a Web based console The di
5. BX600 Digital KVM Switch User Guide PDF Version auf ServerBooks DVD enthalten Further Sources of Information Further information is provided in the RemoteDeploy manual only relevant for cloning server blades the technical manual for the rack the manual for the monitor the ServerView Server Management manual the manual for the Remote Test and Diagnostic System Remote View your operating system documentation the information files of your operating system see also Related Publications on page 165 PRIMERGY BX600 S2 Basic Unit 9 Features Introduction 1 2 Features The PRIMERGY BX600 S2 basic unit provides a high level infrastructure forthe installed server blades Server capacity The PRIMERGY BX600 S2 basic unit provides slots for up to ten hot pluggable server blades For details of the performance features of the different server blade models see the relevant operating manuals listed under Related Publi cations on page 165 Communication interfaces The PRIMERGY BX600 S2 basic unit has four slots on the back for installing different types of communication blades which allow the installed server blades to be connected to the Ethernet LAN or to SAN environments The connections can be implemented via switch blades and or pass thru blades e Ethernet LAN switch blade To connect the server blades to the LAN the following switch blade models are available Gbit Et
6. CAUTION e Make sure you observe the information on determining how many power supply units are required see chapter Power Supply Concept on page 139 e The power supply units switch on automatically at a mains voltage between 200 240 V The base unit may only be commissioned if the local mains voltage is within the voltage range of the system e The 2100 W power supply units may only be connected to 16 Amp grounding outlets or CEE outlets When ordering the base unit indicate the type of outlet available at the installation site This will allow us to supply a cable with suitable inlet connectors for non heating appliances with the order Figure 13 Connecting the basic unit to the mains First connect the insulated connector of the power cables to the power supply units of the basic unit 1 and then plug the power plug 2 into the USV Power Distribution Unit PDU or into an external socket CAUTION Always connect the power cable to the power supply units first and then to the mains 46 PRIMERGY BX600 S2 Basic Unit Installing the Hardware Connecting the System to the Mains Please make sure that each of the power supply units is connected to a il different phase This will provide you with additional phase redundancy for high availability configurations If one phase has failed the power supply units connected to the other phases keep active You can get full phase redundancy with up to
7. Ergonomics manual PDF file available on the ServerBooks DVD supplied Returning used devices manual PDF file available on the ServerBooks DVD supplied Helpdesk leaflet with worldwide helpdesk telephone numbers Technical Manual for the Dxxxx system board PDF file available on the ServerBooks DVD supplied 8 PRIMERGY BX600 S2 Basic Unit Introduction Overview of the Documentation BIOS Setup PDF file available on the ServerBooks DVD supplied ServerView Suite includes the ServerStart Disc 1 the ServerStart Disc 2 and the ServerBooks DVD The PDF version of the PRIMERGY ServerView Suite ServerStart user manual is also available on the ServerBooks DVD If you need a replacement copy of the ServerBooks DVD send the details of your sever to the following e mail address Reklamat PC LOG fujitsu siemens com PRIMERGY BX Blade Server Systems RemoteView Management Blade User Interface Description PDF Version auf ServerBooks DVD enthalten PRIMERGY BX Blade Server Systems LAN Switch Blade User Interface Description PDF Version auf ServerBooks DVD enthalten PRIMERGY BX Blade Server Systems Cisco Catalyst Blade Switch 3040 Hardware Installation Guide PDF Version auf ServerBooks DVD enthalten PRIMERGY BX Blade Server Systems LAN Router and Switch Blade User Interface Description PDF Version auf ServerBooks DVD enthalten
8. The Adv KVM bladeand the digital KVM blade also offers a LAN connectors RJ45 10 Mb see also figure 85 on page 134 42 PRIMERGY BX600 S2 Basic Unit Installing the Hardware Connecting External Devices VGA keyboard mouse to rear purple green KVM board Figure 10 Special cable 4 4 1 Cable Routing The cables are routed directly on the rack support uprights PCI Cards with Cable at the Front If a PCI expansion module is installed in a server blade you will have to connect the PCI port with an external device on the back of the rack To route the cable from the front to the back of the rack use the side slots of the rack with a cable bezel as shown in figure 11 below You may also route the cable to the back of the rack using the space below the basic unit PRIMERGY BX600 S2 Basic Unit 43 Connecting External Devices Installing the Hardware amp Figure 11 Cable routing from the front to the back of the server top view Server blades with SCSI boards installed via PCI expansion modules can only be installed in slots 5 and 6 of the basic unit This is why about 100 mm of space is required in front of the server due to the bend radius of the SCSI cable The curved design of the PRIMECENTER rack door ensures that there is sufficient room for slots 5 and 6 Figure 12 Routing a SCSI cable 44 PR
9. connection panel indicator elements special cable 43 Standard version KVM Blade adv 137 Anschlussfeld 137 Anzeigeelemente 133 133 133 137 L LAN switch blade 81 Control panel 90 dummy module 94 installing 93 95 Port assignment 90 LED system power LED remains unlit 155 lithium battery 24 low voltage directive 15 25 M mains voltage connecting the system 46 Management blade 125 Battery 128 Control panel 126 exchanging 130 meaning of the symbols 14 model rating plate 34 mouse no mouse pointer on screen 158 N Netzteil 11 12 noise level 17 notational conventions 14 notes on safety 21 6 operating elements system 50 overloading 13 overview BX600 basic unit installation steps 19 P packaging 34 password on boot 69 PDA 12 13 Port assignment Ethernet pass thru blade 101 FC pass thru blade 117 FC switch blade 108 LAN switch blade 90 power supply power supply unit system 139 power supply unit indicators 146 replacing 142 Power Unit Display Elements 141 property protection 69 12 139 12 139 R reliability 12 replacing fan unit 151 power supply unit routing cables 43 142 S safety standards 15 saving energy 29 PRIMERGY BX600 S2 Basic Unit Index screen display drifts 158 flickering stripes 158 no display 158 remains dark 157 security functions 8 password on boot 69 supervisor password 69 user password 69 server data protection 69 property protection 69
10. red arrow and click Apply Changes Start Up Operation Code Image File File Name Ak Apply Changes Apply Figure 27 Selecting Start Up Operation Code Image File gt Select Reset in the navigation bar After resetting the switch blade will reboot However all settings specified previously IP address etc will be lost and must be reentered on the management console gt Repeat the firmware update procedure for each installed switch blade PRIMERGY BX600 S2 Basic Unit 67 6 Property and Data Protection The lockable rack door protects the server against unauthorized access To protect your system and data internally against unauthorized access you can use the BIOS Setup security functions Further security options can also be set in the installed operating system If you wish to do this consult your network administrator or refer to the documentation for the corresponding operating system 6 1 BIOS Setup Security Functions The Security menu in BIOS Setup offers various options for protecting data against unauthorized access By combining these options you can achieve optimum protection for the system A detailed description of the Security menu and how to assign passwords can be found in the manual for the BJOS Setup and on the ServerBooks CD see also Related Publications on page 165 Preventing Unauthorized BIOS Setup Calls This protection mechanism can be acti
11. Blade Server Systems Cisco Catalyst Blade Switch 3040 see Related Publications on page 165 PRIMERGY BX600 S2 Basic Unit 87 10 Gbit Switch Blade 10 2 Ethernet Switch Blades 8 4 10 Gbit Switch Blade 10 2 The 10 Gbit switch blade 10 2 is designed to transport all blade server I O including network and storage between the server blades and their associated I O devices The 10 Gbit switch blade 10 2 provides the following features 10 internal 10 Gbit s ports to the server blades 2 external 10 Gbit s ports with optional X2 transceiver modules for Fiber optical or CX4 copper cable 1 console port CAUTION e You may install 10 Gbit switch blades 10 2 only in slots NET3 and NET4 of the basic unit see figure Slots for the switch blades on page 90 e The 10 Gbit switch blade 10 2 only supports server blades with a 10 GbE daughter card installed 10 GbE daughter cards can be installed in server blades BX620 as of version S3 and BX630 as of version S2 88 PRIMERGY BX600 S2 Basic Unit Ethernet Switch Blades 10 Gbit Switch Blade 10 2 Bedien und Anschlussfeld Figure 43 10 Gbit Switch Blade 10 2 Left CX4 port indicator green LED Glows CX4 link established Blinks CX4 link active 1 Right CX4 port indicator green LED Glows CX4 link established Blinks CX4 link active 3 4 CX4 ports 5 Console port link indicator green LED Glows Link availabl
12. CX4 connector 84 PRIMERGY BX600 S2 Basic Unit Ethernet Switch Blades LAN Switch Blade SB9 6x1 Gbit 2x10 Gbit 9 Power system and 10 GbE status indicators green LEDs P Power indicator green LED Glows green Power enabled Dark Power disabled System indicator green LED Glows green The switch has been selected for identification by the management blade Blinks green Error occured CX4 link active indicator green LED Glows green CX4 network link Blinks green CX4 port port XFP link active indicator green LED Glows green XFP network linkr Blinks green XFP port link The information necessary for configuring and operating the Gbit Ethernet LAN switch blade SB9 6x1 Gbit 2x10 Gbit can be found in the manual PRIMERGY BX Blade Server Systems LAN Router and Switch Blade User Interface Description see Related Publications on page 165 PRIMERGY BX600 S2 Basic Unit 85 Cisco Catalyst Blade Switch 3040 Ethernet Switch Blades 8 3 Cisco Catalyst Blade Switch 3040 The Cisco Catalyst Blade Switch 3040 provides the following features 10 internal 1Gbit downlink ports to the server blades 1 console port 2 external 10 100 1000BASE T copper Gigabit Ethernet uplink ports 4 external small form factor pluggable SFP module uplink ports that support 1000BASE SX fiber and 10 100 1000BASE T copper only Cisco SFP modules are supported Ope
13. Ethernet LAN Pass Thru Blades in slots NET3 and NET4 provide connec tions to channels A and B of the optional Gigabit Ethernet I O modules The ports in a configuration with ten 2 way server blades are assigned according to the same formula 102 PRIMERGY BX600 S2 Basic Unit Ethernet Pass Thru Blade Port Assignment Configuration with Five 4 way Server Blades A PRIMERGY BX6xx 4 way server blade offers two onboard LAN controllers with two LAN channels each and two slots for optional Gigabit Ethernet I O modules also with two LAN channels each The Ethernet LAN Pass Thru Blades in slots NET1 and NET2 provide connec tions to channels A and B of the onboard LAN controllers of the server blades The following figure shows the port assignment in a configuration with five 4 way server blades Gigabit Ethernet Gigabit Ethernet pass thru blade 1 pass thru blade 2 Server Server Server Server Server blade 1 blade 2 blade 3 blade 4 blade 5 Figure 56 Port assignment to the onboard LAN controllers with five 4 way server blades PRIMERGY BX600 S2 Basic Unit 103 Port Assignment Ethernet Pass Thru Blade The following figure illustrates the assignment of the LAN ports of the Ethernet LAN Pass Thru Blades in slots NET3 and NET4 to the channels of the Gigabit Ethernet I O modules daughter cards of the server blades in a configuration with five 4 way server blades Gigabi
14. Exit Condole gt enable Console config Console config interface vlan 1 Console config if ip address 10 50 50 51 255 0 0 0 Console config if exit Console show ip interface and address mode User specified Console ie TP address and netmask 10 50 50 51 255 0 0 0 on VLAN 1 v Enter the commands specified above il The specifications for the IP address and the subnet mask are merely examples and are probably not valid for your system gt Terminate the command line session by pressing Strg Q gt Check the newly created LAN connection by pinging the switch blade on the client system gt Install your TFTP server software and start it gt Download the TFTP update package BX600 S2_TFTP IMAGES_ lt version gt exe from the Fujitsu Siemens download server at http www fujitsu siemens com support downloads html PRIMERGY BX600 S2 Basic Unit 65 Updating BX600 System Components Preparation for Use and Operation gt Extract the firmware file bi x to the root directory of the TFTP file system For information on the image file names see the readme file of the update package gt Start an Internet browser on the client server Enter the IP address specified above in the address field Enter the user name and password admin The home page is displayed gt Inthe navigation bar choose Flash File Only two operation code image files can be stored on th
15. Fan Unit on page 151 Lift the basic unit onto the two carrier rails Slide the basic unit into the rack 1 Secure the basic unit in the rack using the four knurled screws 2 40 PRIMERGY BX600 S2 Basic Unit Installing the Hardware Connecting External Devices gt Insert the server blades into their slots see section Adding a Server Blade to the Basic Unit on page 76 Return the power supply units and fan units to the basic unit see section Replacing a Power Supply Unit on page 142 and section Replacing the Fan Unit on page 151 You remove the basic unit by following the above steps in reverse order CAUTION Please note the relevant safety instructions in section Notes on Installing in the Rack on page 28 gt Note the slot assignment of the server blades so that you can insert them correctly again after you have removed the basic unit from the rack Remove server blades fan units and power supplies from the basic unit to reduce weight gt Remove the four knurled screws gt Pull out the basic unit and carefully remove it from the rack 4 4 Connecting External Devices The external connectors of the PRIMERGY BX600 S2 basic unit are located on the rear of the basic unit The external connectors of the server blades are located on the front of the basic unit For information on these connectors see the operating manuals of the different server blade types see Related Publi
16. Guide as well as a detailed description of the different installation options and installation wizards A print version of the ServerStart manual is included in the PRIMERGY ServerView Suite which comes with the BX600 S2 basic unit A PDF version of the manual is contained on the PRIMERGY ServerBooks DVD Cloning of server blades is described in the RemoteDeploy manual print version delivered with RemoteDeploy PDF version contained on the PRIMERGY ServerBooks DVD 20 PRIMERGY BX600 S2 Basic Unit 3 Important Notes In this chapter you will find essential information on safety when working with your system 3 1 Notes on Safety You will also find the following safety instructions in the manual entitled Safety which also includes additional notes on the guarantee and ergonomics This device complies with the relevant safety regulations for data processing equipment including electronic office machines for use in an office environment If you have any questions please contact your sales outlet or the customer service center of Fujitsu Siemens Computers CAUTION The actions described in these instructions should only be performed by technicians service personnel or technical specialists Equipment repairs should only be performed by qualified staff Any failure to observe the guidelines in this manual could expose the user to risks electric shock fire hazards and could also damage the equipment Note that
17. Installation Sequence 2 2 20 ee eee ee eee 73 7 2 Adding a Server Blade to the Basic Unit 76 8 LAN Switch Blades ccs 2 HS eee Bee Se ee 81 8 1 Gbit Ethernet LAN switch blade SB9 6x1Gbit 82 8 2 Gbit Ethernet LAN switch blade SB9 6x1 Gbit 2x10 Gbit 84 8 3 Cisco Catalyst Blade Switch 3040 86 8 4 10 Gbit Switch Blade 1072 22mm 88 8 5 Port Assignment of the LAN Switch Blades 90 8 6 Installing a LAN Switch Blade 22200 93 PRIMERGY BX600 S2 Basic Unit Contents 9 Ethernet Pass Thru Blade 222 99 9 1 Control and Connection Panel 22 222000 100 9 2 Port Assignment of the Gigabit Ethernet Pass Thru Blades 101 9 3 Replacing an Ethernet Pass Thru Blade 104 10 Fibre Channel Switch Blade 2220 nun 105 10 1 Control and Connection Panel 22 2 2000 106 10 2 Port assignment asus uns u HH ini 108 10 3 FC switch blade installation 2 5 111 11 Fibre Channel Pass Thru Blade 2220000 113 11 1 Control and Connection Panel 22 222000 114 11 2 Fibre Channel SFP module 2 2 585 115 11 3 Port Assignment of the FC Pass Thru Blades 117 11 4 Exchanging an FC Pass Thru Blade 121 12 Management Blade 2 020002 eee nee 125 12 1 Control and Connection Panel 22 222000 126 12 2 Exchanging the Battery 222er 128 12 3 Exchanging a Management Blade 2202
18. Interface Card 162 PRIMERGY BX600 S2 Basic Unit Abbreviations NMI Non Maskable Interrupt PCI Peripheral Component Interconnect PDA Prefailure Detection and Analyzing POST Power Up Self Test PSU Power Supply Unit RAID Redundant Arrays of Independent Disks ROM Read Only Memory SAN Storage Area Network SAS Serial Attached SCSI SATA Serial ATA SCA Single Connector Attachment SCSI Small Computer System Interface SCU Server Configuration Utility SFP Small Form Factor Pluggable PRIMERGY BX600 S2 Basic Unit 163 Abbreviations USB Universal Serial Bus VGA Video Graphics Adapter VPD Vital Product Data WOL Wakeup on LAN 164 PRIMERGY BX600 S2 Basic Unit Related Publications PRIMERGY manuals are available in PDF format on the ServerBooks DVD The ServerBooks DVD is part of the PRIMERGY ServerView Suite delivered with each server system The PDF files for the manuals can also be downloaded free of charge from the Internet The overview page showing the online documentation available on the Internet can be found at Attp manuals fujitsu siemens com select industry standard servers 1 2 3 4 5 6 7 8 9 10 11 Safety Ergonomics Warranty DataCenter Rack Technisches Handbuch Technical Manual PRIMECENTER Rack Technisches Handbuch Technical Manual PRIMERGY BX620 Server Blade Operating Manual PRIMERGY BX
19. The minimum requirement is a protected LAN line of category 5 for 10 100 MBps Ethernet and or of category 5e for Gigabit Ethernet The requirements of the specification ISO IEC 11801 must be observed In an emergency e g damage to housing control elements or cables the ingress of liquids or foreign bodies switch the unit off immediately pull the power plug out of the grounding outlet or the CEE outlet and contact Service Proper operation of the device in accordance with IEC 60950 DIN EN 60950 is only ensured if the casing is completely assembled and the dummy units for the installation openings have been put in place electric shock cooling fire protection interference suppression Install only system extensions that satisfy the requirements and rules governing safety and electromagnetic compatibility and relating to telecommunications terminal equipment If you install other exten sions you may damage the system or violate the safety regulations PRIMERGY BX600 S2 Basic Unit 23 Notes on Safety Important Notes and regulations on RFI suppression Information on which system extensions are suitable can be obtained from the customer service center or your sales outlet CAUTION e The components e g power supply marked with a warning label e g lightning symbol may only be opened removed or exchanged by authorized qualified personnel The hot swap or hot plug compo nents are exceptions to this rule e The
20. and connection panel The following indicator and connection elements are provided 1 Serial port connector Standard serial port management communication port 2 LAN connector with two integrated LAN status LEDs see next positions 3 and 4 LAN port RJ45 10Mb management LAN 3 LAN link indicator green LED Lights green The LAN is linked Blinks green Boot up power ready indicator 126 PRIMERGY BX600 S2 Basic Unit Management Blade Control and Connection Panel 4 LAN active indicator amber LED Lights amber The LAN is active Blinks amber Boot up power ready indicator 5 I2C connector Proprietary I2C IPMI connector for Fujitsu Siemens Computers service applications 6 Failure indicator amber LED Dark This management blade is OK see table below Lights amber If only one management blade is present this blade has failed see table below Blinks amber Management blade is running in power up mode gener 2 sec ating heart beat for master slave selection 7 Master indicator green LED Unlit This management blade is a slave standby backup of the master management blade see table below Lights green This management blade is the master responsible for the entire system management see table below Blinks green This management blade is in special mode The following table shows the conditions of the management blades indicat
21. chapter Important Notes on page 21 Do not expose the PRIMERGY BX600 S2 basic unit to extreme environ mental conditions see section Technical Data on page 15 Protect it from dust moisture and heat 4 1 Installation Steps The installation steps are described in detail in the following sections of this chapter e Unpacking the basic unit see section Unpacking the Basic Unit on page 34 e Mounting the basic unit in the rack see section Installing the System in the Rack on page 35 and also the layout arrangement on the order lists e Cabling the basic unit see section Connecting External Devices on page 41 See also the section Cable Routing on page 43 and the section Instructions on Connecting and Disconnecting Cables on page 45 e Connecting the basic unit to the mains voltage see section Connecting the System to the Mains on page 46 PRIMERGY BX600 S2 Basic Unit 33 Unpacking the Basic Unit Installing the Hardware 4 2 Unpacking the Basic Unit CAUTION Please note the safety instructions in the chapter Important Notes on page 21 Do not unpack the PRIMERGY BX600 S2 basic unit until you have finished transporting it We recommend that you do not throw away the original packaging material It may be required for future transportation gt Unpack all the individual parts Check the contents of the package for visible transport damage Check whet
22. designed in accordance with the Fujitsu Siemens Computers standards for environmentally friendly product design and devel opment This means that the designers have taken into account important criteria such as durability selection of materials and coding emissions packaging the ease with which the product can be dismantled and the extent to which it can be recycled This saves resources and thus reduces the harm done to the environment Notes on Saving Energy Devices that do not have to be on permanently should not be switched on until they need to be used and should be switched off during long breaks and on completion of work Notes on Packaging Please do not throw away the packaging It may be needed later for transporting your system unit If possible devices should be transported in their original packaging Notes on Dealing with Consumables Please dispose of printer consumables and batteries in accordance with local government regulations Do not throw batteries and accumulators into the household waste They must be disposed of in accordance with local regulations concerning special waste see also Returning Batteries on page 31 Notes on Labeling Plastic Housing Parts Please avoid attaching your own labels to plastic housing parts wherever possible since this makes it difficult to recycle them PRIMERGY BX600 S2 Basic Unit 29 Environmental Protection Important Notes Returning Used Electrical a
23. household refuse in accordance with the EU directive Figure 3 Symbols for electrical electronic devices 30 PRIMERGY BX600 S2 Basic Unit Important Notes Environmental Protection Returning Batteries Batteries which are marked with one of the following symbols may not be disposed of together with household refuse according to the applicable EU directive Figure 4 Symbols for batteries With batteries containing harmful substances the chemical symbol for the heavy metal contained is indicated below the waste bin Cd Cadmium Hg Mercury Pb Lead The following applies to Germany Private consumers can return batteries at the point of sale or the immediate vicinity thereof free of charge exception starter batteries The final consumer is obligated to return defective or used batteries to the seller or to the return points established for this purpose Local Contacts For details on take back and reuse of devices and consumables within Europe contact your Fujitsu Siemens Computers branch office subsidiary or our recycling centre in Paderborn Fujitsu Siemens Computers Recycling Center D 33106 Paderborn Tel 49 5251 8 18010 Fax 49 5251 8 18015 Internet www fujitsu siemens com recycling PRIMERGY BX600 S2 Basic Unit 31 Installing the Hardware Installation Steps 4 Installing the Hardware CAUTION Please note the safety instructions in the
24. illustrates the assignment of the Fibre Channel ports of the FC pass thru blades and the server blades in a configuration with ten 2 way server blades when two FC pass thru blades and in each server blade an FC daughter board are installed FC pass thru blade1 FC pass thru blade 2 Server blade 1 Server blade 2 Server blade 3 Server blade 4 Server blade 5 Server blade 6 Server blade 7 Server blade 8 Server blade 9 Server blade 10 Figure 72 Fibre Channel port assignment with ten 2 way server blades PRIMERGY BX600 S2 Basic Unit 119 FC Port Assignment FC Pass Thru Blade Configuration with Five 4 way Server Blades Because a 4 way server blade occupies two slots in the blade server chassis there are four connections for four Fibre Channel ports available for a 4 way server blade To use these connections two FC daughter boards must be installed on the 4 way server blade see manual for the relevant server blade type The following figure illustrates the assignment of the FC pass thru blades to the Fibre Channel ports of the server blades in a configuration with five 4 way server blades when two FC pass thru blades and in each 4 way server blade two FC daughter boards are installed in the back of the server Server Server Server Server Server blade 1 blade 2 blade 3 blade 4 blade 5 Figure 73 Fibre Channel port as
25. is the same as for the LAN switch blade see Inserting the LAN Switch Blade on page 95 Inserting the LAN Switch Blade CAUTION Read the safety information and the information on handling electro static sensitive components in the section Components With Electro static Sensitive Devices on page 25 Remove the LAN switch blade from its package PRIMERGY BX600 S2 Basic Unit 95 Installing a LAN Switch Blade Ethernet Switch Blades w Figure 50 Disengaging the switch blade Disengage the locking mechanism of the LAN switch blade by swinging the handle in the direction of the arrow mw N u in u a ER Figure 51 Inserting the switch blade a green touch point Push 1 the LAN switch blade as far as possible into the desired slot here slot 2 gt Swing up 2 the eject handle a of the switch blade until the locking mechanism of the LAN switch blade engages 96 PRIMERGY BX600 S2 Basic Unit Ethernet Switch Blades Installing a LAN Switch Blade Removing the Switch Blade The LAN switch blade is removed in the same way as the dummy module see Removing the Dummy Module on page 94 CAUTION Read the safety information and the information on handling electro static sensitive components in the section Components With Electro static Sensitive Devices on page 25 If you remove the LAN switch blade and do not replace it with a new o
26. module slots must be fitted with a safety plug as shown in the figure below Figure 66 Fibre Channel SFP connector Inserting a Fibre Channel SFP module For each server blade connected via Fibre Channel SFP modules must be plugged into the appropriate FC pass thru blade slots For information on the port assignment see section Installation Sequence on page 73 PRIMERGY BX600 S2 Basic Unit 115 Fibre Channel SFP module FC Pass Thru Blade Figure 67 Inserting an SFP module gt Push the SFP with the label facing upward into the slot assigned to the server blade to be connected Removing an SFP Module Figure 68 Removing an SFP module gt Swivel the locking clip in the direction of the arrow 1 to disengage the locking mechanism of the SFP module and pull it out of the slot 2 116 PRIMERGY BX600 S2 Basic Unit FC Pass Thru Blade FC Port Assignment 11 3 Port Assignment of the FC Pass Thru Blades FC pass thru blades can be installed in slots NET3 and NET4 on the rear of the base unit The FC pass thru blade in slot 1 provides a bypass connection between channel A of the installed fibre channel daughter cards and the corre sponding optical transceivers The FC pass thru blade in slot 2 provides a connection to channel B of the installed fibre channel daughter cards
27. three power supply units With four power supply units two of them are to be connected to one phase see also Related Publications on page 165 Phase redundancy is possible in regions where a single phase provides 200 240V in other regions with lower single phase voltage two phases must be coupled and complete phase redundancy thus is not possible PRIMERGY BX600 S2 Basic Unit 47 5 Preparation for Use and Operation CAUTION e Please note the safety instructions in the chapter Important Notes on page 21 e Beware of energy hazards on the plug in contacts of the midplane A short circuit on these connections can lead to damage to the system All unoccupied component slots are fitted with corresponding dummy modules to ensure that the electromagnetic emission properties of the system are observed and that the system components are cooled properly Figure 14 PRIMERGY BX600 S2 basic unit PRIMERGY BX600 S2 Basic Unit 49 Operating and Indicator Elements Preparation for Use and Operation 5 1 Operating and Indicator Elements of the Basic Unit 5 1 1 The Front 1 II Figure 15 System operating and indicator elements on the front 1 Power indicator bicolor LED Lights amber basic unit is ready for powering ON 5 V standby power present Lights green basic unit is switched ON 2 System power ON OFF button When the basic unit is switched OFF pressing the p
28. warranty is invalidated if the device is damaged during the instal lation or replacement of system extensions e You may set only those resolutions and refresh rates specified in the Technical data section of the monitor description Otherwise you may damage your monitor If you are in any doubt contact your sales outlet or customer service center Batteries CAUTION e Incorrect replacement of batteries may lead to a risk of explosion The battery may only be replaced with an identical battery or with a type recommended by the manufacturer e Do not throw batteries into the trash can They must be disposed of in accordance with local regulations concerning special waste e Replace the lithium battery on the relevant components according to the instructions in this manual e All batteries containing pollutants are marked with a symbol a crossed out garbage can as well as the chemical symbol for the heavy metal which classifies it as a pollutant Cd Cadmium Hg Mercury Pb Lead Other Important Notes e Keep this operating manual and all additional documentation together with the device If you pass on the device to third parties you should also pass on the complete documentation 24 PRIMERGY BX600 S2 Basic Unit Important Notes Components With Electrostatic Sensitive Devices 3 2 Components With Electrostatic Sensitive Devices Electrostatic sensitive components are identified by the following sticker A
29. 0 130 13 KYM Blade 445 Ra Sn a eeeseGee vba taees 133 13 1 KVM Blade Standard Version 222 000 133 13 2 Adv KVM Blades ce ee eee eek Je ee 135 13 3 Digital KVM Blade 2 02 02 ee eee ees 137 PRIMERGY BX600 S2 Basic Unit Contents 14 Power Supply Concept 222 0 139 14 1 Power Supply Units nenn 140 14 1 1 Replacing a Power Supply Unit 142 14 1 2 Adding a Power Supply Unit 145 15 Ventilation Concept 2 2 2 500 eee eee ee 149 15 1 The Fan Unit c ec cc a As HR a nn 150 15 1 1 BeRlaelng NE Fan UE a e og doe Bek edie SOR we Bw pe 151 13 12 Replacnga Fan inthe Unit 30465546244 eee esia 153 16 Troubleshooting and Tips 222 155 16 1 System Power LED Remains Unlit 2222 155 16 2 Front or Rear Identify Fault LED Blinks Amber 156 16 3 System Switches Itself OFF 5000 157 16 4 Screen Remains Dark 22 se ees cee eee ee eee 157 16 5 Flickering Stripes on the Monitor Screen 158 16 6 No Screen Display or Display Drifts 158 16 7 No Mouse Pointer Displayed On the Screen 158 16 8 Floppy Disk Cannot Be Read Written 159 16 9 Time and Date Are Not Correct 222000 159 16 10 Server Blade Does Not Boot 2 25 159 16 11 Defective Drive cs cee ee nn 159 ADDIEVANIONS lt 2 40 Ch dee ORK eee eee Be ee a 161 Related Publications 4 eee Or wee eee teen Fede ORS 165 Index
30. 2 way server blades FC switch blade NET3 FC switch blade NET4 Lo o 4 N m x o o 4 way way ge ge ge 3 3 Server Server S SQ amp S Blade 1 Blade 2 ee cree ee gt gt gt poles z lzs s8 zs 0 0 z0 Fo Fo F0 ND IND DD IND ND AD Figure 63 Fabric port assignment with 4 way and 2 way server blades e When using the 12 port version the fabric ports of the 2 way server l blades 3 and 4 slots 9 and 10 are not available 10 3 FC switch blade installation CAUTION e FC switch blades must always be installed in slot NETS first see page 108 The installation and removal of FC switch blades takes place in the same way as the installation of fibre channel pass thru blades see page 121 PRIMERGY BX600 S2 Basic Unit 111 11 Fibre Channel Pass Thru Blade The 2 2 Gbit Fibre Channel pass thru blade hereinafter referred to as FC pass thru blade provides 10 ports for the bypass connection between FC daughter boards see manual for the relevant server blade type and optical transceivers for serial FC I O and general purpose I O signals The FC pass thru blade features 2 Gbit sec Fibre Channel speed It also provides LEDs for each FC port to indicate the link status FC pass thru blade Figure 64 Fibre Channel pass thru blade The PRIMERGY BX600 S2 basic unit can be fitted with one or two FC pass thru blades The slots fo
31. 25 CE Certificate cc sik ee eda eee an ee 25 FCC Class A Compliance Statement 26 Transporting the Basic Unit 2 27 Notes on Installing inthe Rack 5 28 Environmental Protection 222 220 29 Installing the Hardware 2 02052 800 ee 33 Installation Steps 2 nun 33 Unpacking the Basic Unit 2 22845 34 Installing the System in the Rack 35 Mounting the Assembly Kit 38 Mounting Removing the Basic Unit 40 Connecting External Devices 2 2 45 41 Cable Rouling a r seama 4 4 Ka Re RRR we wR 43 Instructions on Connecting and Disconnecting Cables 45 Connecting the System to the Mains 46 PRIMERGY BX600 S2 Basic Unit Contents 5 Preparation for Use and Operation 49 5 1 Operating and Indicator Elements of the Basic Unit 50 5 1 1 MERONE 2 6 een 50 5 1 2 MERGA oa een ee ee RO 52 5 2 Switching the Basic Unit ON OFF 53 5 3 Management Blade Configuration 55 5 4 Updating System Components 222 00 60 5 4 1 Updating the Server Blade Firmware BIOS and BMC 60 5 4 2 Updating the Management Blade Firmware 62 5 4 3 Updating the Switch Blade Firmware 64 6 Property and Data Protection 222200000 69 6 1 BIOS Setup Security Functions 69 7 Server Blades 2 2 eee eee 71 7 1
32. 620 S2 Server Blade Operating Manual PRIMERGY BX630 Scalable Server Blade Betriebsanleitung PRIMERGY BX660 Server Blade Operating Manual PRIMERGY ServerView Suite ServerStart User Manual PRIMERGY ServerView Suite ServerView S2 Server Management User Manual PRIMERGY BX600 S2 Basic Unit 165 Related publications 12 13 14 15 16 17 18 19 20 21 22 PRIMERGY ServerView Suite ServerView Server Management User Manual PRIMERGY ServerView Suite RemoteView User Manual PRIMERGY RemoteDeploy User Guide PRIMERGY BX Blade Server Systems RemoteView Management Blade User Interface Description User Guide PRIMERGY BX Blade Server Systems LAN Router and Switch Blade User Interface Description User Guide PRIMERGY BX Blade Server Systems Cisco Catalyst Blade Switch 3040 Getting Started Guide PRIMERGY BX Blade Server Systems Cisco Catalyst Blade Switch 3040 Command Reference PRIMERGY BX Blade Server Systems Cisco Catalyst Blade Switch 3040 Hardware Installation Guide PRIMERGY BX Blade Server Systems Cisco Catalyst Blade Switch 3040 Software Configuration Guide PRIMERGY BX Blade Server Systems Cisco Catalyst Blade Switch 3040 System Message Guide BX600 Digital KVM Switch Quick Installation Guide 166 PRIMERGY BX600 S2 Basic Unit Related publications 23 BX600 Digital KVM Switch User Guide 24 BIOS Setup Beschreibung Referenc
33. Ate When you handle components fitted with ESDs you must observe the following points under all circumstances Figure 2 ESD label e Always discharge static build up e g by touching a grounded object before working The equipment and tools you use must be free of static charge Always hold components with ESDs by their edges Do not touch any exposed pins or conductors on a component Use a grounding cable designed for this purpose to connect yourself to the system unit as you install components e Place all components on a static proof base You will find a detailed description of how to handle ESD components in the relevant European or international standards EN 61340 5 1 ANSI ESD 20 20 3 3 CE Certificate The shipped version of this device complies with the requirements of the EEC directives 89 336 EEC Electromagnetic compatibility and 73 23 EEC Low voltage directive The device therefore qualifies for the CE certificate CE Communaut Europ enne PRIMERGY BX600 S2 Basic Unit 25 FCC Class A Compliance Statement Important Notes 3 4 FCC Class A Compliance Statement If there is an FCC statement on the device then The following statement applies to the products covered in this manual unless otherwise specified herein The statement for other products will appear in the accompanying documentation NOTE This equipment has been tested and found to comply with the li
34. IMERGY BX600 S2 Basic Unit Installing the Hardware Connecting External Devices 4 4 2 Instructions on Connecting and Disconnecting Cables CAUTION Make sure you read the documentation on the devices before connecting them Do not connect or disconnect data cables during a thunderstorm When removing a cable always hold it by the plug Connect and disconnect the cables in the order described below Connecting Cables gt Turn off all power and equipment switches gt Pull all power plugs out of grounded power sockets or CEE sockets Plug all cables into the system and peripherals Secure the data trans mission cable connections e g nut retention gt Plug all data communication cables into the utility sockets gt Plug all power cables into the grounded power sockets or CEE sockets Disconnecting Cables gt Turn off all power and equipment switches gt Pull all power plugs out of grounded power sockets or CEE sockets gt Unplug all data communication cables from the utility sockets gt Undo the nut retention on the connector housings and pull the corre sponding cables out of the basic unit and the peripherals PRIMERGY BX600 S2 Basic Unit 45 Connecting the System to the Mains Installing the Hardware 4 5 Connecting the System to the Mains There are slots for four hot swappable 2100 W power supply units on the rear of the basic unit The base system is equipped with two power supply units
35. N activity indicator orange LED Blinks Active LAN connection amber Dark Inactive LAN connection b LAN connection indicator green LED Lights green LAN connection available Dark No LAN connection 100 PRIMERGY BX600 S2 Basic Unit Ethernet Pass Thru Blade Port Assignment 9 2 Port Assignment of the Gigabit Ethernet Pass Thru Blades The PRIMERGY BX600 S2 basic unit offers four slots for Ethernet LAN Pass Thru Blades on the back The Ethernet LAN Pass Thru Blade in slot NET1 is connected to port A of the onboard LAN controller of the installed server blades The Ethernet LAN Pass Thru Blade in slot NET2 is connected to port B of the onboard LAN controller In the same way the Ethernet LAN Pass Thru Blades in slots NET3 and NET4 are connected to port A and B of the gigabit Ethernet daughter cards NET2 CoN NET4 Ooo en 000 Nil e a N Figure 54 Slots for installing pass thru blades The installation of two Ethernet LAN Pass Thru Blades in NET1 and NET2 or NET3 and NET4 enables redundant LAN connections to be provided for the relevant LAN controllers of the server blades CAUTION e Components must always be installed in slots NET1 a
36. PRIMERGY BX600 S2 Basic Unit Operating Manual Edition March 2007 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual Your feedback helps us optimize our documentation to suit your individual needs Feel free to send us your comments by e mail to manuals fujtsu siemens com Certified documentation according to DIN EN ISO 9001 2000 To ensure a consistently high quality standard and user friendliness this documentation was created to meet the regulations of a quality management system which complies with the requirements of the standard DIN EN ISO 9001 2000 cognitas Gesellschaft f r Technik Dokumentation mbH www cognitas de Copyright and Trademarks Copyright 2007 Fujitsu Siemens Computers GmbH All rights reserved Delivery subject to availability right of technical modifications reserved All hardware and software names used are trademarks of their respective manufacturers Contents 1 1 1 2 1 3 1 4 4 1 4 2 4 3 4 3 1 4 3 2 4 4 4 4 1 4 4 2 4 5 Inttodlellan sa 484 2 er oe 7 Overview of the Documentation 22 2000 8 POAIINGS ac ara 10 Notational Conventions 222220 14 Technical Data 2 22 nun 15 Overview Basic Unit Installation Steps 19 Important N tes 22 4 8er BES dee me eee 21 Notes on Safety 2x m ee ee we te eee ees 21 Components With Electrostatic Sensitive Devices
37. PRIMERGY servers are service friendly and modular thus allowing quick and easy maintenance For easy and immediate recognition the levers or handles and locking buttons touch points of the locking mechanisms for the different compo nents have the color green PRIMERGY BX600 S2 Basic Unit 13 Notational Conventions Introduction The flash EPROM program supplied with the Fujitsu Siemens utilities supports fast BIOS update The two redundant and hot swappable management blades with independent management LAN and COM ports ensure complete remote control Together they facilitate remote diagnosis for system analysis remote configuration and remote restart should the operating system or hardware fail 1 3 Notational Conventions The following notational conventions are used in this manual Italics indicate commands menu items or software programs Quotation marks indicate names of chapters and terms that should be emphasized gt Text which follows this symbol describes activities that must be performed in the order given CAUTION Pay particular attention to text marked with this symbol Failure to observe this warning may endanger your life damage the server or lead to loss of data il This symbol introduces supplementary information remarks and tips Table 1 Notational conventions 14 PRIMERGY BX600 S2 Basic Unit Introduction Technical Data 1 4 Tech
38. Read Written 16 8 Floppy Disk Cannot Be Read Written gt Check whether the write protection of the floppy disk is activated Check the entry for the floppy disk drive in the BIOS Setup for the corre sponding server blade Check the BIOS Setup for the corresponding server blade to see whether the floppy disk drive controller and write permission are enabled 16 9 Time and Date Are Not Correct gt Set the time and or date in the operating system or in the BIOS Setup for the corresponding server blade If the time and date are repeatedly wrong when you switch on your server blade you must change the lithium battery see the manual for the relevant server blade type 16 10 Server Blade Does Not Boot The server blade does not boot after a defective hard disk drive has been replaced Incorrect SCSI configuration onboard SCSI HostRAID controller gt Inthe SCSI configuration menu check the settings for the hard disk drives SCSI Device Configuration and the additional settings Advanced Config uration Options 16 11 Defective Drive Drives are identified as dead on system start The configuration of the RAID controller is wrong gt Check and correct the settings for the drives using the utility for the RAID controller For more details see the manual for the RAID controller on the ServerBooks CD under the heading Controllers PRIMERGY BX600 S2 Basic Unit 159 Defective Drive Troubleshooting a
39. Switch Blade Besides the 16 ports version the switch blade unit is available as a 12 ports version with eight internal and four external fabric ports The PRIMERGY BX600 S2 base unit can be fitted with two FC switch blades The slots for the FC switch blades are on the rear of the base unit NET3 and NET4 in figure 60 on page 108 Section Port Assignment on page 108 describes how the fibre channel ports of the server blades are assigned to the FC switch blades PRIMERGY BX600 S2 Basic Unit 105 Control and Connection Panel FC Switch Blade 10 1 Control and Connection Panel Figure 59 Control and Connection Panel of the FC switch blade External FC connection 6x socket for LWL or SWL FC SFP module see section Fibre Channel SFP module on page 115 RJ45 LAN connection with two integrated status LEDs see items 6 and 7 FC switch blade voltage status display green LED lights up when the base unit is switched on 12 V input voltage present FC switch blade status display 2 color LED Dark FC switch blade is not operating Lights green FC switch blade is operating Lights amber Boot phase one or more ports are off line Blinks amber green Warning a fault has occurred il The LED might also
40. Troubleshooting and Tips 16 2 Front or Rear Identify Fault LED Blinks Amber If the front or rear identify fault indicator blinks amber see section Operating and Indicator Elements of the Basic Unit on page 50 one of the malfunctions described below may have occurred in the system One of the power supply units fails The PSU status LED is unlit and or the PSU fan failure LED blinks green ifthere is an error in the corresponding power supply unit e g see also figure Power supply unit LEDs on page 141 General failure alert or fan 1 shutdown Overtemperature any of the fans are not working properly in the corre sponding unit Overcurrent Over or undervoltage The PSU is reaching the end of its life or is operating in an environment which exceeds the specified limits Check the PSU status and or fan failure LEDs to identify the defective unit and exchange it see section Replacing a Power Supply Unit on page 142 One of the fans in the rear fan modules has failed Even though the system can continue operating without one of the fans in the rear fan modules you should Exchange the defective front fan module within a reasonable amount of time see section Replacing the Fan Unit on page 151 and section Replacing a Fan in the Unit on page 153 Switch blade fails The failure LED of the switch blade lights up if there is a general error there gt Check the swi
41. ade select the menu System Property Environ Maintenance Firmware Update Server Blade BMC or System Property Environ Maintenance Firmware Update Server Blade BIOS il For security reasons the BIOS and BMC firmware can only be updated if the relevant server blade was shut down beforehand otherwise the update option is not offered in the web menu Server Blade BIOS System Property Environment Maintenance Firmware Update Server Blade BIOS TFTP Server IP Address Specify Boot Image File Name bios rom Server Blade 1 Server Blade 2 _ADD gt gt Server Blade 3 Server Blade 4 Server Blade 5 DEL lt lt Apply t Figure 22 Updating the server blade BIOS via the web interface gt In the TFTP Server IP Address field enter the IP address of the TFTP server which provides the BIOS image file for the server blade firmware In the Boot Image File Name field enter the file name of the boot image file for the server blade Use the Add and Delete buttons to select the server blades whose BIOS is to be updated Click the Apply button The update file is transferred to all selected server blades and the update process is started The progress of the update process is shown in a status screen Once the update process is complete the server blade s is are restarted Repeat the procedure to update the BMC firmware see figure 23 PRIMERGY BX600 S2 Basic Unit 61 Updating BX600 System Comp
42. an 8 way two 4 way and two 2 way server blades 7 2 Adding a Server Blade to the Basic Unit Depending on the desired configuration the system can be upgraded with up to 10 server blades CAUTION e Read the safety information and the information on handling electro static sensitive components in the section Components With Electrostatic Sensitive Devices on page 25 e Energiegefahr neu Removing the Dummy Module All unoccupied slots in the basic unit are fitted with dummy modules to ensure that the electromagnetic emission properties of the system are observed and that the system components are properly cooled 76 PRIMERGY BX600 S2 Basic Unit Server Blades Adding a Server Blade to the System If you wantto add a server blade you must first remove the dummy module from the corresponding slot amp 4 Figure 35 Removing a server blade dummy module Release the locking mechanism of the ejecting handles by pressing the touch points on the inside of both handles 1 simultaneously The ejecting handles of the dummy module will be disengaged Swing up the upper handle and swing down the lower handle simultaneously 2 until the locking mechanism of the dummy module disengages and the dummy module ejects Remove the dummy module completely from the slot 3 CAUTION Keep the dummy module for future use If the server blade is removed and not replaced with a new server blade t
43. any unauthorized opening of the device will result in the invalidation of the warranty and exclusion from all liability PRIMERGY BX600 S2 Basic Unit 21 Notes on Safety Important Notes Before Setting Up CAUTION During installation and before operating the device observe the instructions on environmental conditions for your device in the section Technical Data on page 15 Ifthe device is brought in from a cold environment condensation may form on both the inside and outside of the machine Before operating the device wait until it is absolutely dry and has reached approximately the same temperature as the installation site Failure to observe these guidelines can lead to physical damage of the device Transport the device only in the original packaging or in packaging which protects it from knocks and jolts Installation and Operation CAUTION For safety reasons make sure you read any warning labels when removing modules from the server Beware of energy hazards on the plug in contacts of the midplane A short circuit on these connections can lead to damage to the system PRIMERGY BX620 S4 server blades are not for use in slots 4 an 10 of the PRIMERGY BX600 S2 basic unit If the server is integrated in a rack installation that receives power from an industrial public power supply network with the IEC309 connector the public power supply protection must comply with the requirements for the non industria
44. at the front of the blade server was pressed to identify the system Pressing one of the two ID buttons again deactivates the ID LED Checksum error System error Blinks green KVM connector Allows a VGA monitor PS2 keyboard and PS2 mouse to be connected via a special cable see figure 10 on page 43 134 PRIMERGY BX600 S2 Basic Unit KVM Blade Adv KVM Blade 13 2 Adv KVM Blade The adv KVM blade offers the same functionality as the standard version ofthe KVM blade plus a LAN port for connecting a Web based console with the following features Console emulation in graphics mode Makes the CD ROM drive of the client PC available as a virtual USB 1 1 2 0 CD ROM drive with boot option Makes the floppy disk drive of the client PC available as a virtual USB 1 1 2 0 floppy disk drive with boot option Software controlled server blade selection Password protected user authentication The IP address of the adv KVM blade is configured and the Web based console Global View is invoked via the Web interface of the management blade For more information on the adv KVM blade see the manual PRIMERGY BX Blade Server Systems RemoteView Management Blade User Interface Description Control Panel of the Adv KVM Blade Figure 86 Adv KVM blade PRIMERGY BX600 S2 Basic Unit 135 Adv KVM Blade KVM Blade Rear ID button If you press the ID butto
45. be ks Bee bees rare een 169 PRIMERGY BX600 S2 Basic Unit Introduction 1 Introduction The PRIMERGY BX600 S2 Blade Server System represents a highly compact power saving and scalable servers for integration in 19 inch rack systems Figure 1 PRIMERGY BX600 S2 Basic Unit The PRIMERGY BX600 S2 basic unit occupies seven height units in the rack and can accommodate up to ten server blades of different models and configu rations As economical ultra compact systems the server blades with up to eight CPUs are ideal for use by company data centers and Internet service providers They are perfectly suited for large application servers terminal servers for CPU intensive applications and DBMS servers The PRIMERGY BX600 S2 Blade Server System offers a high level of reliability and availability through highly developed hardware and software components This includes hot swappable server blades switch blades Fibre Channel FC and Ethernet pass thru blades management blades hot swappable power supply units and fan modules the server management software ServerView and Remote Deploy Prefailure Detection and Analyzing PDA and Automatic Server Reconfiguration and Restart ASR amp R PRIMERGY BX600 S2 Basic Unit 7 Overview of the Documentation Introduction Security functions in the BIOS Setup protect the data on the server blades against manipulation Additional security is provided by the lockable rac
46. blink while testing Management blade display 2 color LED Lights up when the FC switch blade is being controlled directly via the management blade user interface 106 PRIMERGY BX600 S2 Basic Unit FC Switch Blade Control and Connection Panel 6 LAN speed display green LED Dark LAN transfer rate 10 Mbit s Lights green LAN transfer rate 100 Mbit s 7 LAN activity indicator of the FC switch blade amber LED Dark No connection Lights LAN connection is available Blinks Data transport 8 Status display of ext FC ports 2 color LED Dark No signal reception Flickers green FC port on line data transport Blinks green slow FC port on line but segmented fast internal loop Lights amber Signal reception but not on line Blinks amber slow 2 sec intervals FC port disabled fast 0 5 sec interval FC port faulty 9 Speed display of ext FC port 2 color LED Dark FC transfer rate 1Gbit s Lights green FC transfer rate 2Gbit s Lights amber FC transfer rate 4Gbit s PRIMERGY BX600 S2 Basic Unit 107 Port Assignment FC Switch Blade 10 2 Port Assignment Connections to the two fabric ports of the optional fibre channel daughter card are provided for each of the ten server blade slots In the case of 4 way server blades connections for a total of four fabric ports are therefore available The FC switch blade in the NETS slot is connected
47. ca tions on page 165 PRIMERGY BX600 S2 Basic Unit 41 Connecting External Devices Installing the Hardware Connectors on the back of the basic unit Figure 9 Connectors for external devices Slots for various types I O blades connected to the server blades on board NICs These I O blades can be Ethernet switch blades or Ethernet pass thru blades see Ethernet LAN Switch Blades on page 81 and Ethernet Pass Thru Blade on page 99 2 8 Slots for various types I O blades connected to the optional I O modules of the server blades These I O blades can be Ethernet or Fibre Channel switch blades or pass thru blades see Ethernet LAN Switch Blades on page 81 Ethernet Pass Thru Blade on page 99 Fibre Channel Switch Blade on page 105 and Fibre Channel Pass Thru Blade on page 113 3 Serial port connector on management blade 2 see also figure 53 on page 100 Standard serial port management communication port LAN connector on management blade 2 see also figure 53 on page 100 LAN port RJ45 10Mb management LAN Serial port connector on management blade 1 see also figure 53 on page 100 Standard serial port management communication port LAN connector on management blade 1 see also figure 53 on page 100 LAN port RJ45 10Mb management LAN KVM connector on rear KVM blade which offers VGA PS2 keyboard and mouse support via a special cable see figure 10 below
48. ches off If one of the small fans on the rear fails the power supply unit continues to run See figure 90 for the location of the power supply unit fans When the base unit is operating normally LEDs 1 and 3 will be on all the time and LED 2 will be off If LED 2 signals a fault by lighting up the power supply unit affected must be replaced as soon as possible This can be done while the base unit is still running see page 142 PRIMERGY BX600 S2 Basic Unit 141 Power Supply Units Power Supply Concept 14 1 1 Replacing a Power Supply Unit If a power unit fails the front orange ID LED blinks in the system unit operator panel The defective power unit can be replaced while the base unit is still running CAUTION Do not under any circumstances remove a fan module if a power supply unit fails The 2100 W power supply unit is not downwardly compatible It may only be used in the S2 variant of the PRIMERGY BX600 base unit If a system fault occurs and the front ID LED fault LED blinks the fault must be remedied before additional components can be removed or added To ensure continuous air circulation through the chassis the slots for the power supply units must not be left empty and or open for more than five minutes when the system is running Components may be damaged if this five minute limit is exceeded gt Check the FAN LED of the power supply units on the back of the system see figure 90 on page 141 to determin
49. e 6 Console port active indicator amber LED Dark 1 Gbit s link available Glows 100 Mbit s link available Blinks Link active 7 Power indicator amber LED Dark Power enabled Glows Power disabled 8 ID indicator green LED Glows Switch blade is operating Blinks The switch blade has been selected for identification by the management blade PRIMERGY BX600 S2 Basic Unit 89 Port Assignment of the LAN Switch Blades Ethernet Switch Blades 8 5 Port Assignment of the LAN Switch Blades For each of the ten server blade slots connections are available to the two ports ofthe onboard LAN controllers and to the two ports of the optional gigabit Ethernet daughter card In the case of 4 way server blades connections for a total of eight LAN ports are therefore available The LAN switch blade in the NET1 slot is connected to port A of the onboard LAN controller of the installed server blades The switch blade in slot NET2 is connected to port B of the onboard LAN controller In the same way the LAN switch blades in slots NET3 and NET4 are connected to port A and B of the gigabit Ethernet daughter cards a a S eee coool _ 000 K
50. e LEDs can be activated via a pushbutton b after the fan unit has been removed from the chassis 150 PRIMERGY BX600 S2 Basic Unit Ventilation Concept The Fan Unit 15 1 1 Replacing the Fan Unit CAUTION If asystem error has occurred and the front identify fault LED is blinking the error must be resolved before any additional components are added or removed Make sure that all necessary power supply units are inserted and functioning before you remove and or install one of the fan units CAUTION The system can continue operating without one fan The defective fan must be replaced within a reasonable amount of time max 2 minutes N j P VAN i N CONNAN XS y Figure 97 Disengaging the fan unit a green touch point gt Press the locking button green to disengage the locking mechanism of the unit handle PRIMERGY BX600 S2 Basic Unit 151 The Fan Unit Ventilation Concept Aa Figure 98 Removing the fan unit gt Swivel the handle completely down to disengage the locking mechanism and pull out the rear fan unit To mount a fan unit follow these instructions in the reverse order 152 PRIMERGY BX600 S2 Basic Unit Ventilation Concept The Fan Unit 15 1 2 Replacing a Fan in the Unit Figure 99 Disengaging the fan unit a green touch point gt Pull 1 the locking handle green to disengage the fan g
51. e Manual PRIMERGY BX600 S2 Basic Unit 167 Index 10 GBit CX4 Anschluss 84 10 GBit XFP Anschluss 84 A adding server blade 76 Adv KVM blade 135 connection panel 135 indicator elements 135 Adv KVM Blade 137 approvals product safety 15 ASR amp R 12 availability 12 B Battery exchanging 128 Management blade 128 BIOS security functions 69 BIOS update 13 BX600 basic unit installation steps overview 19 external devices 45 consumables 29 Control panel Ethernet pass thru blade 100 FC switch blade 106 LAN switch blade 90 Management blade 126 D data manipulation 8 data protection 69 date incorrect 159 delivery note 34 dimensions 16 disconnecting cables 45 Display Elements Power Unit 141 drive defective 159 dummy module installing 76 LAN switch blade 94 server blade 76 Cc E cables ECC 12 connecting 45 electrical data 15 disconnecting 45 electromagnetic compatibility 15 25 carrier rail 39 EMC 15 CE label 15 25 environmental conditions 17 Class A Compliance Statement 26 environmental protection 29 component hot swappable 12 components hardware software 7 configuring server 13 connecting cables 45 PRIMERGY BX600 S2 Basic Unit 5 Index error defective drive 159 display drifts 158 flickering stripes on screen floppy disk cannot be read written 159 incorrect date 159 incorrect time 159 no display on screen 158 no mouse pointer 158 screen remains dark 157 server blade does not boot sys
52. e Redirection TFTP update Logout Reboot Management Blade System Information Dump er selection Connected 0 04 01 vr oo h soen Sal A NUM apur Pant ech Figure 18 Console menu 56 PRIMERGY BX600 S2 Basic Unit Preparation for Use and Operation Management Blade Configuration gt Enter 1 to call up the Management Agent menu The Management Agent menu looks like this e Hyperterminat p Hyperterminal 1 13 ile Wew Cal Transfer Help olej 8 3 la 5 Hanagement Agent Information Hanagement Blade System Information Server Blade Switch Blade Username And Password Blue Screen Event Log Set System Default Server Blade CHOS Backup Restore Switch Blade Configuration Backup Restore Deployment Parameter PPP and Modem Setting Fiber Channel a Power Consumption er selection or type to quit frico fissoosm SRo cars num Cape _ Prntecho Figure 19 Management Agent menu gt Enter 1 to call up the Management Agent Information menu The Management Agent Information menu provides access to the parameters required by the LAN connection PRIMERGY BX600 S2 Basic Unit 57 Management Blade Configuration Preparation for Use and Operation Eile Edt Yew Cal Transfer Help olej 8 3 la Management Agent IP Address 10 90 90 20 Management Agent Network Mask 299 299 Management Agent Gateway t A Management Agent Default Route LAN Management Agen
53. e switch blade If there are already two image files stored you must remove at least one of them before updating the firmware It is recommended that you remove the older file i e the file with the lower number Expand the File Name list red arrow in the Remove Operation Code Image File section to check if there are already two image files stored on the switch blade If so select the older one in the File Name list and click Remove File Remove Operation Code Image File File Name bix Remove File x Figure 25 Removing an operation code image file Enter TFTP Server IP Address Source File Name bix and Destination File Name 66 PRIMERGY BX600 S2 Basic Unit Preparation for Use and Operation Updating BX600 System Components 5 jitsu Siemens Computers L Port11 Mode Active FUJITSU ces Beh Blade 1 k A SIEMENS ee l LinkUp f Link Down Port 13 Firmware Configuration Transfer Operation Code Image File from Server Current Operation Code Version 0 9 1 0 TFTP Server IP Address 0 0 0 0 Source File Name Destination File Name 1 V0 9 1 1 bix 7 Transfer from Server Figure 26 Transferring the new operation code image file Click Transfer from Server gt Wait a few minutes until the update process is complete Refresh the browser for viewing gt Select the new image file in the pop up window
54. e which power supply unit is defective gt First disconnect the power supply cable of the defective PSU from the mains Remove the power supply cable from the insulated socket of the defective PSU CAUTION Be careful The PSU can be very hot 142 PRIMERGY BX600 S2 Basic Unit Power Supply Concept Power Supply Units gt Press the locking button a to disengage the locking mechanism of the PSU handle PRIMERGY BX600 S2 Basic Unit 143 Power Supply Units Power Supply Concept Figure 92 Removing the power supply unit gt Swivel the handle completely in the direction of the arrow to unlock the PSU from the chassis 144 PRIMERGY BX600 S2 Basic Unit Power Supply Concept Power Supply Units Figure 93 Removing the PSU gt Pull the PSU out of the slot CAUTION Be careful The PSU can be very hot To mount a PSU follow these instructions in reverse order 14 1 2 Adding a Power Supply Unit Depending on the desired configuration the system can be upgraded with one or two additional power supply units CAUTION Read the safety information in the chapter Important Notes on page 21 PRIMERGY BX600 S2 Basic Unit 145 Power Supply Units Power Supply Concept CAUTION Because of chassis airflow disruption the power supply unit slot should not be vacant and or uncovered for more than five minutes when the system power is ON Exceeding t
55. ed by the interaction of master indicator and failure indicator LEDs Management blade condition Master indicator Failure indicator green LED amber LED One management blade is ON OFF installed and alive Two management blades are ON Master OFF installed OFF Slave One management blade is ON ON installed and hangs up Two management blades are ON ON installed and both hang up PRIMERGY BX600 S2 Basic Unit 127 Exchanging the Battery Management Blade 12 2 Exchanging the Battery In order to save the system information permanently a lithium battery is installed to provide the CMOS memory with a current When the charge is too low or the battery is empty a corresponding error message is provided The lithium battery must then be replaced CAUTION Read the safety information and the information on handling batteries in the section Batteries on page 24 Incorrect replacement of batteries may lead to a risk of explosion The battery may only be replaced with an identical battery or with atype recommended by the manufacturer Make sure you insert the battery the right way round The plus pole must be at the top The following figure shows the position of the battery 1 on the management blade board Figure 79 Position of the management blade battery arrow 128 PRIMERGY BX600 S2 Basic Unit Management Blade Exchanging the Battery F
56. eginning on page 49 gt Insert the server blades into the slots in the front of the BX600 S2 basic unit see chapter 7 on page 71 gt Configure the management blades see section 5 3 on page 55 so that you can perform further administration of the blade server system via LAN gt Install the desired operating systems and applications on the server blades To do so you have the following options Cloning a server blade from a remote image server with RemoteDeploy Recommended if the following requirements are satisfied the RemoteDeploy software is available an appropriate cloning image is available deployment server and LAN connection are available PRIMERGY BX600 S2 Basic Unit 19 Overview Basic Unit Installation Steps Remote installation with ServerStart This installation method is recommended if a LAN connection and a DHCP server are available but the requirements for cloning are not satisfied Local installation with or without ServerStart Since the local installation is the least convenient installation method it is only recommended if the requirements for remote installation or cloning are not satisfied If you wish to install an operating system that is not supported by Server Start you can perform the installation directly without using ServerStart For further information on remote or local installation of server blades please see the ServerStart manual which contains a Quick Step
57. ent Blade BMC TFTP Server IP Address 192 168 51 20 Agent Update IP Address 192 168 52 245 Boot Image File Name mgmt133B bin TFTP Update Enable disable z Apply t Controller time 03 09 2004 11 34 53 2000 2004 Fujitsu Siemens Computers Figure 24 Updating the management blade firmware via the web interface gt gt Make sure that both management blades are connected to the LAN Enter the IP address of the TFTP server on which the image file for the management blade firmware is provided Enter an IP address in the Agent Update IP Address field The IP address in the Agent Update IP Address field is only used tempo rarily so you can enter any IP address that is not used in the LAN segment of the server In the Boot Image File Name field enter the name of the image file of the management blade Set the value ofthe TFTP Update Enable field to enable Click Apply The firmware of the first management blade Master will now be updated the green LED lights up When the update process is complete this management blade is defined as the Slave and the second management blade which used to be the Slave is now defined as the Master Repeat the update process for the second management blade After the update process for the second management blade the original Master Slave configuration is automatically restored PRIMERGY BX600 S2 Basic Unit 63 Updating BX600 System Components Preparation for Use and Operation
58. er management blade is indicated by a green LED see section Control and Connection Panel on page 126 Initial Configuration via Serial Connection to Client gt Open a HyperTerminal session from the client to the master management blade Use the following settings Bits per second 115200 Data bits 8 Parity None Stop bit 1 Flow control None Terminal type VT100 PRIMERGY BX600 S2 Basic Unit 55 Management Blade Configuration Preparation for Use and Operation Once you have opened the HyperTerminal session the welcome screen of the console menu will be displayed see figure 17 below iolz Bile Edit view Gall Transfer Help Dis 213 ala Welcome to Management Blade 1 31C lt Username gt root lt Password gt Connected 0 01 56 Mio 115200 80 1 oL Cas num Cae Print ech Figure 17 Welcome screen gt Loginas root The initial password reads root CAUTION Change the root password as soon as possible see page 56 Failure to do so may result in unauthorized access and loss of customer data You can change the root password of the management blade via menu item 6 Username and Password of the Management Agent menu see figure 19 on page 57 When you have logged on the main menu of the console menu will be displayed Hyper TerminalMB Hyper Terminal 5I xj Be Wew Gall Transfer Help Die 813 55 a Management Agent Emergency Management Port Consol
59. ered or 0 The transfer rate of 10 Mbit sec and the duplex mode of the i management blade must comply with the client LAN controller Automatic synchronization is not supported by the management blade LAN controller gt Enter 0 in this menu and in the preceding menus to leave the management blade console menu Close the HyperTerminal session gt Unplug the power cable from the basic unit and plug it in again to reboot the management blade This ensures that the management blade continues to act as the master after the restart A restart without interruption to the power supply would cause the master slave assignment to change The management blade can now be accessed via the LAN For more infor mation on the management blade configuration see the manual PRIMERGY BX Blade Server Systems RemoteView Management Blade User Interface Description Information on the configuration of the various switch blade models can be found in sparate manuals see Related Publications on page 165 PRIMERGY BX600 S2 Basic Unit 59 Updating BX600 System Components Preparation for Use and Operation 5 4 Updating System Components All files required for updating the PRIMERGY BX600 S2 basic unit components are available from http www fujitsu siemens com support downloads html 5 4 1 Updating the Server Blade Firmware BIOS and BMC You can update both the firmware of the server blade BIOS and the firmware of the se
60. gital KVM blade offers the same functionality as the standard version of the KVM blade plus a LAN port for connecting a Web based console Power Supply Up to four hot swappable power supply units which adjust automatically to any power voltage in the range 200 240 V in a 2 2 redundant power supply config uration ensure enough power for the system If one of these units fails the others ensure that operation continues unimpaired The defective power supply unit can be replaced during operation hot swap Ventilation The system is kept cool by three fans in each power supply unit and four single fans with two of them mounted one after the other in a housing in the rear chassis This configuration is redundant and hot swappable High Level of Availability and Failure Protection When memory data is accessed 1 bit errors in the main memory are recog nized and automatically corrected with the ECC Error Correcting Code method ASR amp R Automatic Server Reconfiguration and Restart restarts the system in the case of an error and automatically hides the defective system components The PDA Prefailure Detection and Analyzing technology from Fujitsu Siemens Computers analyzes and monitors all components relevant for system reliability The hot swappable components provide additional failure protection Failure protection on a complete blade system is ensured by up to four redundant hot swap power supply units PSU as well a
61. he five minute limit may damage components All unoccupied PSU slots in the blade server system are fitted with PSU dummy modules figure 94 to ensure that the electromagnetic emission properties of the system are observed and that the system components are properly cooled Each PSU dummy module includes three fans respectively There is one LED indicator 1 on figure 94 on the front of the PSU dummy module for monitoring the status of built in fans Figure 94 PSU dummy module If you want to install an additional power supply unit you must first remove the PSU dummy module from the corresponding slot Remove the PSU dummy module from the corresponding slot Removal installation is the same as for the power supply unit see section Replacing a Power Supply Unit on page 142 146 PRIMERGY BX600 S2 Basic Unit Power Supply Concept Power Supply Units CAUTION Keep the dummy module for future use If you remove a power supply unit and do not replace it with a new one you must reinstall the dummy module gt Insert the additional power supply unit in the corresponding slot and connect it to the mains PRIMERGY BX600 S2 Basic Unit 147 15 Ventilation Concept The basic unit is kept cool by two fan units two fans each and the fans in the power supply units three fans in each PSU and or the fans in the PSU dummy unit s two fans in each dummy The fan units are accessible from t
62. he rear of the system and contain two fans each Figure 95 PRIMERGY BX600 S2 basic unit fan units When a fan in a fan or power supply unit PSU dummy module fails the amber front identify LED see figure 15 on page 50 on the front panel blinks You can find out which unit is defective by checking the fan status via the server management software ServerView Even though the system can continue operating with a defective fan the defective fan or power supply unit PSU dummy module should be replaced as soon as possible For how to replace a power supply unit PSU dummy module see section Replacing a Power Supply Unit on page 142 Due to the hot swap architecture replacement is also possible during operation PRIMERGY BX600 S2 Basic Unit 149 The Fan Unit Ventilation Concept 15 1 The Fan Unit The fan unit includes two redundant fans There are four LED indicators figure 96 on the front ofthe fan unit for fan status monitoring Figure 96 The fan unit Fan 1 LEDs Fan 2 LEDs Fan condition 1 2 4 3 green amber green amber Present and OK ON OFF ON OFF Not present OFF OFF OFF OFF Present and failed ON ON ON ON Table 2 Fan unit indicators In addition for each fan in the unit an error LED driven by backup capacitor is available These two LEDs a are located on the top of the fan unit to indicate the respective defective fan Th
63. he server blade see the manual for the relevant server blade type To switch OFF the server blade press the power button of the server blade see the manual for the relevant server blade type for 4 seconds Specified switch ON time switch OFF time The server blade is switched ON or OFF at a time specified in the ServerView program Ring indicator The server blade is switched ON via an external modem After power failure The server blade automatically switches ON following a power failure depending on the settings in the BIOS 54 PRIMERGY BX600 S2 Basic Unit Preparation for Use and Operation Management Blade Configuration 5 3 Management Blade Configuration The two redundant management blades provide functionality for remote control of the PRIMERGY BX600 S2 base unit over the LAN see chapter Management Blade on page 125 and the PRIMERGY BX Blade Server Systems RemoteView Management Blade User Interface Description manual To commission the base unit the LAN parameters ofthe management blades must be set using a local client computer To configure the management blade follow the steps listed below Pre Configuration Requirements The procedures that follow assume that the basic unit is connected to the power line Cabling the System gt Connect the serial interface of the client COM1 to the serial interface of the master management blade using an RS232 cable null modem cable The mast
64. hen the dummy module must be reinstalled for cooling to comply with the applicable EMC regulations regulations on electromagnetic compatibility and for fire protection PRIMERGY BX600 S2 Basic Unit 77 Adding a Server Blade to the System Server Blades Installation is the same as for the server blade see Inserting the Server Blade on page 78 Inserting the Server Blade CAUTION Read the safety information and the information on handling electro static sensitive components in the section Components With Electro static Sensitive Devices on page 25 AAAAAAAAAD ARAAAAAAAA ANRARAARARAR N Ss o gt a Lf N Figure 36 Turning the eject handles into the unlocked position 2 way server blade Press the touch points on the inside of the eject handles 1 of the server blade to disengage the locking mechanism of the handles Turn the eject handles outward 2 into the unlocked position The 4 way server blade has the same locking mechanism see figure 37 Figure 37 Turning the eject handles into the unlocked position 4 way server blade How to install a server blade is described in the following using the example of a 2 way server blade 4 way server blades are installed in the same way 78 PRIMERGY BX600 S2 Basic Unit Server Blades Adding a Server Blade to the System Figure 38 Inserting the server blade gt Push the server blade
65. her the delivery matches the details in the delivery note The identification rating plate is located on the front edge of the left side of the basic unit If you find transport damage or inconsistencies between the contents of the package and the delivery note inform your supplier immediately 34 PRIMERGY BX600 S2 Basic Unit Installing the Hardware Installing the System in the Rack 4 3 Installing the System in the Rack CAUTION e For safety reasons at least two people are required to install the PRIMERGY BX600 S2 basic unit because of its weight and size e Please observe the safety precautions and references to rack instal lation in the chapter Important Notes on page 21 e The rack may tip over if more than one unit is removed at the same time Requirements of the Rack The rack systems from Fujitsu Siemens Computers GmbH PRIMECENTER rack DataCenter rack fully support the installation of the PRIMERGY server systems Installation in the common rack systems of other manufacturers 3rd party rack is supported to a large degree To accommodate the ventilation concept and ensure proper ventilation of the components in the rack any unused areas must be closed using dummy covers The unit is connected to the power supply via an external distribution board or a UPS device The main features of the rack systems from Fujitsu Siemens Computers GmbH are PRIMECENTER DataCenter Rack Frontally bolted rail
66. hernet LAN switch blade SB9 6x1Gbit 10 internal 1Gbit downlink ports to the server blades 6 external 1Gbit uplink ports RJ45 Gbit Ethernet LAN switch blade SB9 10Gbit multi mode 10 internal 1Gbit downlink ports to the server blades 6 external 1Gbit uplink ports RJ45 2 external 10Gbit uplink ports 1xSFP 1xCX4 Cisco Catalyst Blade Switch 3040 10 internal 10 1Gbit downlink ports to the server blades 2 external 10 100 1000BASE T copper Gigabit Ethernet uplink ports 4external uplink ports via Cisco SFP modules for 1000BASE SX Fibre Optic and 10 100 1000BASE T copper 10 PRIMERGY BX600 S2 Basic Unit Introduction Features 10 Gbit switch blade 10 2 10 internal 10 Gbit s ports to the server blades 2external 10 Gbit s ports with optional X2 transceiver modules for Fiber optical or CX4 copper cable The 10 Gbit switch blade 10 2 only supports server blades each equipped with a 10 GbE daughter card All switch blades are hot swappable By installing two switch blades redundant LAN connections can be provided for the server blades e Ethernet LAN Pass Thru Blade The Ethernet LAN Pass Thru Blade is an alternative to the switch blade It provides direct pass thru connections to the LAN for the onboard LAN controllers and the optional Gigabit Ethernet I O modules of the server blades The Ethernet LAN Pass Thru Blade has ten RJ45 connectors e Fibre Channel pass thru blade
67. identify Fault indicator green LED Lights green This system has been selected for identification identify LED is lit by pressing the front or rear identify button To deselect the system press either of the identify buttons again Blinks green SUM error A malfunction has occurred in the system 1 Figure 16 shows the operator panel of the standard KVM blade For further information on this KVM blade and on the adv KVM blade see chapter KVM Blade on page 133 52 PRIMERGY BX600 S2 Basic Unit Preparation for Use and Operation Switching the Blade Server ON OFF 5 2 Switching the Basic Unit ON OFF CAUTION e Make sure that the PRIMERGY BX600 S2 basic unit is connected to the mains for at least one minute before pressing the power ON OFF button to switch the system ON e If after switching the basic unit ON you can only see flickering stripes on the attached monitor switch the system OFF immediately see chapter Troubleshooting and Tips on page 155 e The system ON OFF power button does not disconnect the system from the mains voltage To completely disconnect it you must remove the power plugs from the sockets Switching ON the Basic Unit Basic Unit is Powered OFF gt Press the basic unit power ON OFF button position 2 in figure 15 on page 50 for 2 seconds Depending on the BIOS settings the server blades can be switched on automatically one after another according to the slot nu
68. ification substitution or attachment will be the responsibility of the user The use of shielded I O cables is required when connecting this equipment to any and all optional peripheral or host devices Failure to do so may violate FCC and ICES rules 26 PRIMERGY BX600 S2 Basic Unit Important Notes Transporting the Basic Unit 3 5 Transporting the Basic Unit CAUTION Transport the PRIMERGY BX600 S2 basic unit only in its original packaging or in a packaging which protects it from knocks and jolts Do not unpack the basic unit until you have finished transporting it For safety reasons at least two people are needed to install the basic unit because of its weight and size Before lifting the basic unit into the rack remove server blades fan units and power supplies from the system unit to reduce weight Use the handles on the front and the fold away handles on the long sides to lift or carry the base unit Never lift or transport the basic unit using the handles on the rear PRIMERGY BX600 S2 Basic Unit 27 Notes on Installing in the Rack Important Notes 3 6 Notes on Installing in the Rack CAUTION For safety reasons at least two people are needed to install the basic unit because of its weight and size For lifting the basic unit use the handles on the front and the fold out handles on the long sides of the chassis Before lifting the basic unit into the rack remove server blades fan units and
69. igure 80 Inserting removing the management blade battery Push the holding spring in the direction of the arrow 1 so that the lithium battery pops out of its holder and remove the battery 2 Place the new battery of the same type in the holder 3 and push it in the direction of the arrow 4 until it slots into place PRIMERGY BX600 S2 Basic Unit 129 Exchanging a Management Blade Management Blade 12 3 Exchanging a Management Blade CAUTION Read the safety information and the information on handling electro static sensitive components in the section Components With Electro static Sensitive Devices on page 25 Removing the Management Blade Figure 81 Disengaging the management blade gt Press the spring on the underside of the eject handle to unlock it 130 PRIMERGY BX600 S2 Basic Unit Management Blade Exchanging a Management Blade Figure 82 Disengaging the management blade gt Swing the eject handle of the management blade in the direction of the arrow until the locking mechanism disengages and the blade is ejected a few centi meters PRIMERGY BX600 S2 Basic Unit 131 Exchanging a Management Blade Management Blade Figure 83 Removing the management blade Remove the management blade from the slot CAUTION Both management blades must always be plugged in to ensure cooling to comply with the applicable EMC regulations regulat
70. ile the second must be mounted level with the upper edge of the first The brackets are used for the rear fixing of the left carrier rail gt See the installation instructions in the technical manual for the relevant rack model gt Mark the position of the lower edge of the basic unit on the support uprights DI LPF DI LIDS Figure 6 Mounting the support brackets Place the first support bracket at the appropriate height level with the lower edge of the device on the left rear support upright by inserting the positioning nubs 1 in figure 6 in the corresponding holes of the support upright Place the plug washers in the holes of the support uprights and secure the bracket with two screws 38 PRIMERGY BX600 S2 Basic Unit Installing the Hardware Installing the System in the Rack gt Repeat the procedure with the second support bracket Note that the second bracket will be mounted level with the upper edge of the first support bracket mounted see figure 6 on page 38 Figure 7 Mounting the left carrier rail gt Undo the six screws 1 for adjusting the rail length and place the guide lugs a in the corresponding holes of the support brackets Place three plug washers 3 in the appropriate holes of the support brackets and while holding the rail in place fasten it with three screws Place two plug
71. into the slot as far as possible while keeping the eject handles in the unlocked position Please make sure you install the server blade in the right direction The upper narrow side of the server blade is marked TOP SIDE 1 PRIMERGY BX600 S2 Basic Unit 79 Adding a Server Blade to the System Server Blades T Figure 39 Final engaging of the locking mechanism gt Press the eject handles to enable the locking mechanism to engage fully Removing the Server Blade The server blade is removed in the same way as the dummy module see Removing the Dummy Module on page 76 CAUTION Read the safety information and the information on handling electro static sensitive components in the section Components With Electro static Sensitive Devices on page 25 When you remove the server blade and do not replace it with a new one you must insert a dummy module in the empty slot Make sure that the dummy module engages in the slot correctly 80 PRIMERGY BX600 S2 Basic Unit 8 Ethernet LAN Switch Blades This chapter outlines the main features of the switch blades available with the PRIMERGY BX600 S2 blade server For each switch blade it describes the indicator and connection elements of the control and connection panel This chapter also describes the port assignment to the server blades and how to install and uninstall the switch blades in the basic unit The information necessary for configu
72. ion You can also connect cables from the BX600 digital KVM switch to a KVM appliance such as the Fujitsu Siemens s3 1621 Console Switch This capability allows you to create large combinations of servers and switches that you can manage from a common access point or over your IP network The information necessary for configuring and operating the various switch blade models can be found in separate manuals see Related Publications on page 165 The IP address of the Digital KVM blade is configured and the Web based console is invoked via the Web interface of the management blade For more information on the digital KVM blade see the separate manuals listed in Related Publications on page 165 PRIMERGY BX600 S2 Basic Unit 137 Digital KVM Blade KVM Blade Control panel of the digital KVM blade Figure 87 Digital KVM blade 1 LAN connection LAN port RJ45 10 100 Mbit s LED A LAN transfer rate indicator LED B LAN link indicator 2 Power indicator Glows Power enabled Blinks Power disabled 2 KVM connection Offers support for VGA and PS2 keyboard and mouse via a special cable see figure 10 on page 43 or for the connection to an external console switch 4 ID indicator Glows The system has been selected for identification by pressing the front or rear ID button Blinks System failure 138 PRIMERGY BX600 S2 Basic Unit 14 Power Supply Concept In
73. ions on electro magnetic compatibility and for fire protection The management blade is inserted by following these instructions in reverse order 132 PRIMERGY BX600 S2 Basic Unit 13 KVM Blade For administering the server blades the PRIMERGY BX600 S2 basic unit offers a KVM blade which allows the individual server blades to be connected to a console Figure 84 Position of the KVM blade The following models are available KVM blade standard version Adv KVM blade Digital KVM blade 13 1 KVM Blade Standard Version The standard KVM blade allows a monitor PS2 keyboard and PS2 mouse to be connected for local administration of the server blades This requires a special cable see figure 10 on page 43 The server blade is assigned to the KVM blade by pressing the KVM button on the control panel of the server blade to be administered PRIMERGY BX600 S2 Basic Unit 133 KVM Blade Standard Version KVM Blade Control Panel of the KVM Blade Standard Version 12 8 Figure 85 KVM blade Rear ID button When you press the ID button the ID LEDs on the control panel on the front of the server blade and on the KVM blade are switched on or off The ID LEDs on the KVM blade and on the control panel of the blade server are synchronized ID error LED green LED Glows green The ID button on the KVM blade or the ID button on the control panel
74. k door 1 1 Overview of the Documentation PRIMERGY manuals are available in PDF format on the ServerBooks DVD The ServerBooks DVD is part of the PRIMERGY ServerView Suite delivered with each server system The PDF files for the manuals can also be downloaded free of charge from the Internet The overview page showing the online documentation available in the Internet can be found via the URL http manuals fujitsu siemens com primergyservers html Concept and Target Group of this Manual This operating manual is intended for those responsible for installing the hardware and operating the system The manual contains all the information required for mounting and operating your PRIMERGY BX600 S2 basic unit For a brief overview of the installation steps please see chapter 2 on page 19ff To understand the different expansion options you need a knowledge of hardware and data transmission as well as basic knowledge of the operating system used Additional server documentation The PRIMERGY BX600 S2 documentation also includes Quick Start Hardware PRIMERGY BX600 S2 S3 leaflet Quick Start Software PRIMERGY ServerView Suite leaflet Warranty manual print version supplied with the system PDF file available on the ServerBooks DVD supplied Safety notes and other important information manual print version supplied with the system PDF file available on the ServerBooks DVD supplied
75. l public power supply networks for the type A connector For the PRIMERGY BX600 S2 basic unit only 2100W PSUs are allowed Product no A3C40073262 The 1200W PSUs of the PRIMERGY BX600 S1 basic unit is not allowed for the PRIMERGY BX600 S2 basic unit The 2100W PSU is not allowed for the PRIMERGY BX600 S1 basic unit 22 PRIMERGY BX600 S2 Basic Unit Important Notes Notes on Safety Make sure that the PRIMERGY BX600 S2 basic unit is connected to the mains for at least one minute before pressing the power ON OFF button to switch the system ON Q CAUTION The server automatically adjusts to a mains voltage of 200 240 V The server may only be put into operation if the mains voltage range set on the server corresponds to the local mains voltage This device has safety tested power cables and must only be connected to properly grounded power sockets or CEE sockets The power button does not disconnect the device from the mains voltage To completely disconnect it from the mains voltage the power plugs must be removed from the power socket Data transmission cables must not be connected or disconnected during a thunderstorm lightning hazard Make sure that no objects such as bracelets or paper clips or liquids fall spill into the device risk of electric shock or short circuit Data cables must be adequately shielded to avoid interference The LAN wiring must comply with the standards EN 50173 and EN 50174 1 2
76. mbering see figure 29 on page 72 gt f necessary switch ON the required server blades see Switching the Server Blades ON OFF on page 54 The basic unit is switched ON and the activated server blades perform a system test and boot the operating system Switching OFF the Basic Unit System is Powered ON The basic unit is operating server blades are also switched ON gt For graceful shutdown of all server blades press the system power ON OFF button position 2 on figure 15 on page 50 for 4 seconds The server blades will then be powered OFF gt For hard shutdown of all server blades press the system power ON OFF button position 2 on figure 15 on page 50 for 10 seconds The server blades will be powered OFF immediately PRIMERGY BX600 S2 Basic Unit 53 Switching the Blade Server ON OFF Preparation for Use and Operation Other Ways to Switch ON the Basic Unit Using the web interface of the management blade Using the web interface of the management blade you can switch on the basic unit as well as each of the server blades After power failure The basic unit automatically switches ON following a power failure and the server blades which were operating before the power failure are booted automatically Switching the Server Blades ON OFF The basic unit must be powered ON The server blade can be switched ON and OFF in the following ways To switch ON the server blade press the power button of t
77. mits for a Class A digital device pursuant to Part 15 ofthe FCC rules and meets all requirements of the Canadian Interference Causing Equipment Standard ICES 003 for digital apparatus These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in strict accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that inter ference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures e Reorient or relocate the receiving antenna e Increase the separation between equipment and the receiver e Connect the equipment to an outlet on a circuit different from that to which the receiver is connected e Consult the dealer or an experienced radio TV technician for help Fujitsu Siemens Computers is not responsible for any radio or television inter ference caused by unauthorized modifications of this equipment or the substi tution or attachment of connecting cables and equipment other than those specified by Fujitsu Siemens Computers The correction of interferences caused by such unauthorized mod
78. n the ID LED on the rear lights up The front and the rear ID LEDs are synchronized Rear ID error LED green LED Glows green The system has been selected for identification by pressing the front or rear ID button LED glows Press one of the ID buttons to deactivate the ID LED Checksum error System error Blinks green KVM connector Supports the connection of a VGA monitor PS2 keyboard and PS2 mouse via a special cable see figure 10 on page 43 4 LAN connection with two integrated LAN status LEDs see the following items 5 and 6 LAN port RJ45 10 100 Mbit s 5 LAN activity indicator green LED Dark LAN connection not active Blinks green Active LAN connection 6 LAN connection indicator orange LED Dark No connection Glows LAN connection available 136 PRIMERGY BX600 S2 Basic Unit KVM Blade Digital KVM Blade 13 3 Digital KVM Blade The digital KVM blade offers the same functionality as the standard version of the KVM blade plus a LAN port for connecting a Web based console with the following features Console emulation in graphics mode Makes the CD ROM drive of the client PC available as a virtual USB 1 1 2 0 CD ROM drive with boot option Makes the floppy disk drive of the client PC available as a virtual USB 1 1 2 0 floppy disk drive with boot option Software controlled server blade selection Password protected user authenticat
79. n Sequence On the front of the PRIMERGY BX600 S2 basic unit are ten slots for server blades numbered 1 10 from left to right Figure 30 BX600 S2 basic unit with ten 2 way server blades All ten slots are connected to the infrastructure modules on the back of the BX600 S2 basic unit via the midplane of the BX600 S2 basic unit Switch blade s Fibre Channel pass thru blade s optional Ethernet pass thru blade s optional Management blade s KVM blade Power supply units CAUTION PRIMERGY BX620 S4 server blades are not for use in slots 4 an 10 of the PRIMERGY BX600 S2 basic unit In a PRIMERGY BX600 S2 basic unit different models and configurations of server blades can be operated alongside each other PRIMERGY BX600 S2 Basic Unit 73 Installation Sequence Server Blades The order in which the server blade slots are filled depends on whether you are using 2 way server blades or 4 way server blades or a mix of the two and how the server blades are equipped Configuration Diagram for 2 way Server Blades Slot 4 is filled first Next slots 5 through 10 are filled in numerical order followed by slots 1 through 3 2 way server blades with SCSI controller in a PCI extension module can only be installed in slots 5 and 6 because of the cabling arrangement in the rack see section Cable Routing on page 43 Figure 31 I
80. nd Electronic Devices in EU Countries Separate collection Users of electrical and electronic devices are obligated to collect used devices separately Electrical electronic used devices may not be disposed of together with unsorted household refuse The separate collection is a condition for reuse recycling and utilisation of used electrical electronic devices which ensures the protection of resources Return and collection systems Electrical electronic used devices from private households can be returned free of charge To return your used device please use the country specific return and collection systems available to you see Local Contacts on page 31 The return of used devices which pose a health or safety risk for human beings due to soiling during use may be refused Reuse recycling and utilisation By actively using the offered return and collection systems you make your contribution to the reuse recycling and utilisation of electrical electronic devices Effects on the environment and human health Electrical electronic used devices contain parts which must be handled selectively according to the EU directive Separate collection and selective treatment are the basis for environment friendly disposal and the protection of human health Meaning of the symbol Crossed out rubbish bin on wheels Electrical electronic devices which are marked with one of the following symbols may not be disposed of with
81. nd NETS first This ensures that port A of the relevant LAN controller is connected if redundant LAN connections are not used e To provide fibre channel functionality FC pass thru blades see page 113 or FC switch blades see page 105 must be installed in slot NET3 and or slot NET4 Asynchronous balanced mode of Ethernet blades and fibre channel blades in slots NET3 and NET4 is not permitted The following configuration examples show the assignment of the Ethernet ports of the pass thru blades to the server blades PRIMERGY BX600 S2 Basic Unit 101 Port Assignment Ethernet Pass Thru Blade Configuration with Ten 2 way Server Blades A PRIMERGY BX6xx dual server blade offers an onboard LAN controller with two LAN channels and a slot for an optional Gigabit Ethernet I O module with two extra LAN channels The Ethernet LAN Pass Thru Blades in slots NET1 and NET2 provide connec tions to channels A and B of the onboard LAN controllers of the server blades The following figure shows the port assignment in a configuration with ten 2 way server blades Gigabit Ethernet pass thru blade 1 Gigabit Ethernet pass thru blade 2 Server blade 1 Server blade 2 Server blade 3 Server blade 4 Server blade 5 Server blade 6 Server blade 7 Server blade 8 Server blade 9 Server blade 10 Figure 55 Ethernet port assignment with ten 2 way server blades The
82. nd Tips Added drive is identified as defective The RAID controller is not configured for the drive The drive was probably installed while the system was switched off You can configure the RAID controller for the drive after its installation using the relevant utility For how to do this see the documentation for the RAID controller on the ServerBooks CD under the heading Controllers or Remove the drive and reinstall it with the system switched on If the drive is still identified as defective you will need to replace it 160 PRIMERGY BX600 S2 Basic Unit Abbreviations ASR amp R Automatic Server Reconfiguration and Restart ATA Advanced Technology Attachment BIOS Basic Input Output System CD Compact Disk COM Communication CPU Central Processing Unit DBMS Database Management System DDR Double Data Rate RAM DIMM Dual Inline Memory Module DVD Digital Video Disk ECC Error Correcting Code EDC Error Detection Code EMC Electromagnetic Compatibility PRIMERGY BX600 S2 Basic Unit 161 Abbreviations ESD FC GAM HDD HU 1 0 IDE LAN LCD LED MRL NIC Electrostatic Discharge Fibre Channel Global Array Manager Hard Disk Drive Height Unit Input Output Identification Integrated Drive Electronics Internet Protocol Local Area Network Liquid Crystal Display Light Emitting Diode Manually Retention Latch Network
83. ne you must insert a dummy module in the empty slot to ensure cooling to comply with the applicable EMC regulations regulations on electromagnetic compatibility and for fire protection Make sure that the dummy module engages in the slot correctly PRIMERGY BX600 S2 Basic Unit 97 9 Ethernet Pass Thru Blade The Ethernet LAN Pass Thru Blade provides ten RJ45 ports for direct pass thru connections to the server blades Figure 52 Ethernet LAN Pass Thru Blade The PRIMERGY BX600 S2 basic unit offers slots for up to four Ethernet LAN Pass Thru Blades on the back see figure 54 on page 101 Depending on the specific slot an Ethernet LAN Pass Thru Blade establishes connections to the onboard LAN controllers or to the optional Gigabit Ethernet I O modules daughter cards of the server blades For information on the optional Gigabit Ethernet I O modules daughter cards see the operating guides for the relevant server blade types PRIMERGY BX600 S2 Basic Unit 99 Control and Connection Panel Ethernet Pass Thru Blade 9 1 Control and Connection Panel uy Figure 53 Control and connection panel of the Ethernet LAN Pass Thru Blade The following display and control elements are available 1 10 RJ45 connectors The RJ45 connectors are assigned to the server blades in accordance with their numbering for server blade slot numbering see figure 30 on page 73 a LA
84. nical Data Electrical Data single power supply unit Rated voltage range 200 240 V Rated frequency 50 Hz 60 Hz Max rated current 230V 11 6 A Max active power 230 V 2650 W Max apparent power 2680 VA 230V Thermal dissipation 2050 kJ h Protection class Electrical Data basic unit without server blades Power consumption 360 W Thermal dissipation 1300 kJ h Compliance Standards Product safety and ergonomics IEC 60950 EN 60950 UL 1950 3rd Edition CSA 22 2 No 950 Electromagnetic compatibility Emitted interference Harmonic current Noise immunity FCC class A EN 55022 class A EN 61000 3 2 EN 55024 CE label according to EU directives Low Voltage Directive 73 23 EEC Electromagnetic Compatibility 89 336 EEC Certification Product safety Global CB PRIMERGY BX600 S2 Basic Unit Technical Data Introduction Europe ENEC Germany GS USA Canada CSAys CSAc Japan VCCI Mechanical Values Width 446 mm Installation depth 740 mm Height 307 mm oder 7 HE Weight max 131 5 kg depending on the configuration PRIMERGY BX600 S2 Basic Unit Introduction Technical Data Environmental Conditions Environment class 3K2 Environment class 2K2 DIN IEC 721 section 3 3 DIN IEC 721section 3 2 Temperature Operation 3K2 T
85. nstallation sequence for 2 way server blades 74 PRIMERGY BX600 S2 Basic Unit Server Blades Installation Sequence Configuration Diagram for 4 way Server Blades Slots 3 and 4 are filled first Next slots 5 through 10 are filled in pairs in numerical order followed by slots 1 and 2 Figure 32 Installation sequence for 4 way server blades Configuration Diagram for a Mix of 2 way and 4 way Server Blades The 4 way server blades are fitted first followed by the 4 way server blades Begin with a 4 way server blade in slots 3 and 4 1 2 3 4 5 6 7 8 9 10 oO E 5 1 2 3 4 5 D 2 6 D n gt E Q Figure 33 Installation sequence for three 2 way and three 4 way server blades 2 way server blades with SCSI controller can only be fitted in slots 5 and 6 If only one 2 way server blade with SCSI controller is to be fitted it must go in slot 5 with a dummy server blade in slot 6 PRIMERGY BX600 S2 Basic Unit 75 Adding a Server Blade to the System Server Blades Configuration Diagram for a Mix of an 8 way Server Blade with 4 way and 2 way Server Blades Begin with the 8 way server blade in slots 1 4 followed by the 4 way Server Blades and the 2 way Server Blades il Server blades with SCSI controller can only be fitted in slots 5 and 6 Figure 34 Installation sequence for
86. o ensure that the electromagnetic emission properties of the system are observed and that the system components are properly cooled 14 1 Power Supply Units The power supply units PSU are directly accessible at the rear of the system figure 88 on page 139 The power supply unit can communicate with the system service processor via an internal management interface IIC bus The PSU part number FRU data barcode number manufacturer ID and fault data are stored ina VPD EEPROM module and can be recalled via the IIC bus The PSU status can be displayed in the server management software ServerView Each power supply unit has a large fan on the front A and two smaller fans on the rear B that provide air cooling for the system see figure 89 below front rear Figure 89 PSU Fans 140 PRIMERGY BX600 S2 Basic Unit Power Supply Concept Power Supply Units Figure 90 Power supply unit LEDs There are three LED displays on the front of the unit to allow the status of the power supply unit to be monitored 1 On off display green LED D Lights up when the PRIMERGY BX600 S2 base unit is switched on 2 Fault display amber LED N Lights up if a fault occurs on the power supply unit or if a fan fails 3 Mains power supply display green LED Q Lights up when the mains connection is re established If the large fan on the front fails the power supply unit swit
87. onents Preparation for Use and Operation Server Blade BMC System Property Environment Maintenance Firmware Update Server Blade BMG TFTP Server IP Address Specify Boot Image File Name bmctftp bin Server Blade 1 Server Blade 2 _ ADD gt gt Server Blade 3 Server Blade 4 Server Blade 5 DEL lt lt Apply t Figure 23 Updating the server blade BMC via the web interface 5 4 2 Updating the Management Blade Firmware CAUTION The procedure described below must be performed for each of the two management blades Proceed as follows gt Install your TFTP server software and start it Copy the relevant firmware file bin to the root directory of the TFTP file system Check the LAN connection by pinging the relevant management blade gt Enter the IP address of the TFTP server which provides the BMC image file for the management blade firmware Enter the path and the file name of the image file for the management blade You have two options for doing this 1 Inthe management console Telnet select the TFTP Upgrade submenu Activate the option Management Blade TFTP Update 2 In the web interface of the management blade select the entry System Property Environment Maintenance Firmware Update Management Blade BMC Update 62 PRIMERGY BX600 S2 Basic Unit Preparation for Use and Operation Updating BX600 System Components i Management Blade Managem
88. onitor Screen CAUTION Switch OFF the server blade immediately Monitor does not support the set horizontal frequency Find out which horizontal frequency your monitor screen supports You will find the horizontal frequency also known as the line frequency or horizontal deflection frequency in the documentation for your monitor gt For how to set the correct horizontal frequency for your monitor refer to the documentation for your operating system or the software for your screen controller and follow the procedure accordingly 16 6 No Screen Display or Display Drifts Wrong horizontal frequency or resolution selected for the monitor or for the application program Find out which horizontal frequency your monitor supports You will find the horizontal frequency also known as line frequency or horizontal deflection frequency in the documentation for your monitor gt For how to set the correct horizontal frequency for your monitor refer to the documentation for your operating system or the software for your screen controller and follow the procedure accordingly 16 7 No Mouse Pointer Displayed On the Screen Mouse driver not loaded Check whether the mouse driver is properly installed and activated Infor mation on the mouse driver can be found in the documentation for the mouse the operating system or the application program 158 PRIMERGY BX600 S2 Basic Unit Troubleshooting and Tips Floppy Disk Cannot Be
89. ower button for 2 seconds will switch it ON O When the basic unit is operating and the button is kept pressed for 4 seconds the basic unit will be gracefully shut down When the basic unit is switched ON pressing the power button for 10 seconds will switch it OFF 50 PRIMERGY BX600 S2 Basic Unit Preparation for Use and Operation Operating and Indicator Elements Front identify Fault indicator amber LED Unlit Lights amber Blinks amber The system is normal and not highlighted If power indicator LED lights green basic unit is switched ON 5 V standby power present This system has been selected by pressing the front or rear identify button To deactivate press one of the buttons again You also can activate the LED via CLI The system is directly controlled via the management blade user interface or SUM error A malfunction has occurred in the system Front identify button Pressing this button lights up the integrated front identify indicator The front and rear identify indicators will be synchronized PRIMERGY BX600 S2 Basic Unit 51 Operating and Indicator Elements Preparation for Use and Operation 5 1 2 TheRear Figure 16 System operating and indicator elements on the rear 1 Rear identify button Pressing this button lights up the rear identify indicator The front and rear identify indicators will be synchronized 2 Rear
90. power supplies from the system unit to reduce weight For lifting the basic unit use the handles on the front and the fold out handles on the long sides of the chassis Never lift or transport the server using the handles on the rear For safety reasons only one unit may be withdrawn from the rack ata time when performing assembly or service work Ensure that the anti tilt bracket is correctly mounted when you set up the rack If more than one unit is withdrawn from the rack at any one time the rack is in danger of tilting forward When connecting and disconnecting cables read the relevant notes in the Important notes chapter in the technical manual for the relevant rack The technical manual is supplied with the corre sponding rack The power connection for the rack must be installed by an authorized technician electrician If the server is integrated in a rack installation that receives power from an industrial public power supply network with the IEC309 connector the public power supply protection must comply with the requirements for the non industrial public power supply networks for the type A connector The power supply for the rack should be divided amongst the three phases of a three phase power connection 28 PRIMERGY BX600 S2 Basic Unit Important Notes Environmental Protection 3 7 Environmental Protection Environmentally Friendly Product Design and Development This product has been
91. r these blades are on the back of the system unit NET 3 and NET4 in figure 69 on page 117 If Fibre Channel functionality is to be available for one or more server blades at least one FC pass thru blade or FC switch blade must be installed The assignment of the Fibre Channel channels is described in section Port Assignment of the FC Pass Thru Blades on page 117 PRIMERGY BX600 S2 Basic Unit 113 Control and Connection Panel FC Pass Thru Blade 11 1 Control and Connection Panel Figure 65 FC pass thru blade control connection panel The following indicator and connection elements are provided a Fibre Channel active indicator green LED Fibre Channel link indicator amber LED c Fibre Channel SFP connector Slot for Fibre Channel SFP module see page 115 The slot numbers are assigned to the server blade slots on the front of the BX600 S2 system see figure 29 on page 72 The following table shows the conditions of the Fibre Channel ports indicated by the LEDs Fibre Channel condition a b Power ON ON ON Fibre Channel is online ON OFF Signal acquired OFF ON Loss off synchronization ON Blinks 114 PRIMERGY BX600 S2 Basic Unit FC Pass Thru Blade Fibre Channel SFP module 11 2 Fibre Channel SFP module A Fibre Channel SFP module is required to connect an FC pass thru blade port to a Fibre Channel cable If no cable is plugged in the SFP
92. ransport 2K2 5 0 35 C 20 C 60 C Relative humidity 10 85 Condensation during operation must be avoided Noise Level Sound power level Lwag ISO 7779 7 8 BA Sound pressure level at bystander position lt 59 dB A in the Loam ISO 9296 standard configuration PRIMERGY BX600 S2 Basic Unit 2 Overview Basic Unit Installation Steps In this chapter you will find an overview of the steps necessary to install your BX600 S2 basic unit Links guide you to sections where you can find more detailed information on the individual steps Before you begin please read the chapter Important Notes beginning on page 21 especially the section Notes on Safety gt Unpack the system check the contents of the package for visible transport damage and check whether the delivery matches the details in the delivery note see section 4 2 on page 34 gt Mountthe system in the rack see section 4 3 on page 35 and also the layout arrangement on the order lists Cable the system see section 4 4 on page 41 Please also see the section Cable Routing on page 43 and the section Instructions on Connecting and Disconnecting Cables on page 45 Connect the system to the mains voltage see section 4 5 on page 46 gt Familiarize yourself with the operating and indicator elements on the front and rear sides of the BX600 S2 basic unit see chapter 5 b
93. rating and Indicator Elements ORO RO ye CLE D0 Figure 42 Cisco Catalyst Blade Switch 3040 1 Console port 2 Console port indicator bicolor LED Dark The bootloader is initializing Glows green The blade switch console port is active Glows amber The blade switch console port is inactive the management blade backplane console is active Glows green or Cisco IOS is operating normally amber 3 System status ID indicator green LED Glows green ID The switch has been selected for identification by the management blade 86 PRIMERGY BX600 S2 Basic Unit Ethernet Switch Blades Cisco Catalyst Blade Switch 3040 4 Gigabit Ethernet ports Gigabit Ethernet port indicators bicolor LEDs Dark No link established Glows green Link established but no activity Blinks green Traffic on an established link Glows amber Port disabled either error or STP1 disabled Glows green or Link fault amber 6 SFP module ports SFP module port indicators bicolor LEDs Dark No link established Glows green Link established but no activity Blinks green Traffic on an established link Glows amber Port disabled either error or STP1 disabled Glows green or Link fault amber The information necessary for configuring and operating the Cisco Catalyst Blade Switch 3040 can be found in the manual PRIMERGY BX
94. ring and operating the various switch blade models can be found in separate manuals see Related Publications on page 165 The following switch blade models are available Gbit Ethernet LAN Switch Blade SB9 6x1Gbit Gbit Ethernet LAN Switch Blade SB9 6x1 Gbit 2x10 Gbit Cisco Catalyst Blade Switch 3040 10 Gbit Switch Blade 10 2 PRIMERGY BX600 S2 Basic Unit 81 LAN Switch Blade SB9 6x1Gbit Ethernet Switch Blades 8 1 Gbit Ethernet LAN Switch Blade SB9 6x1Gbit The Gbit Ethernet LAN switch blade SB9 6x1Gbit supports layer 2 3 4 functionality and offers the following connections 10 internal 1Gbit downlink ports to the server blades 6 external 1Gbit uplink ports via RJ45 connectors Operating and Indicator Elements Figure 40 Gbit Ethernet LAN switch blade SB9 6x1Gbit 1 6 1 Gbit uplink LAN connectors with two integrated LAN status LEDs each LED A LAN active indicator bicolor LED Glows amber Port link at 1 Gbit s Glows green Port link at 100 Mbit s Dark Port link at 10 Mbit s LED B LAN link indicator yellow LED Glows yellow Network link Blinks yellow Network activity Dark No network link or port disabled 82 PRIMERGY BX600 S2 Basic Unit Ethernet Switch Blades LAN Switch Blade SB9 6x1Gbit 7 Power and system indicators green LEDs P Power indicator green LED Glows green Power enabled Dark Power disabled S System indica
95. rver blade 5 Server blade 6 Server blade 7 Figure 45 LAN port assignment with ten 2 way server blades PRIMERGY BX600 S2 Basic Unit 91 Port Assignment of the LAN Switch Blades Ethernet Switch Blades Configuration with Five 4 way Server Blades The following figure illustrates the assignment of the switch blades to the LAN ports of the server blades in a configuration with five 4 way server blades Switch blade 1 Switch blade 2 Server Server Server Server Server blade 5 blade 1 blade 2 blade 3 blade 4 Figure 46 LAN port assignment with five 4 way server blades 92 PRIMERGY BX600 S2 Basic Unit Ethernet Switch Blades Installing a LAN Switch Blade Configuration with a Combination of 2 way and 4 way Server Blades The following figure illustrates the assignment of the switch blades to the LAN ports of the server blades in a configuration with two 4 way server blades and six 2 way server blades Switch blade 1 Switch blade 2 To Re a N lt b o 4 way 4 way xe xe ne xo xo ne server server i amp S x a Q blade 1 blade 2 Ko S 2 a gt 00 gt o gt o gt gt gt ollie RO 7o FS z5 Fol Fol FS ADIA D ADINGD AA AD Figure 47 LAN port assignment with 4 way and 2 way server blades 8 6 Installing a LAN Switch Blade Depending on the desired configuration the
96. rver blade BMC BMC stands for Baseboard Management Controller The BMC on the server blade collects management information and forwards it to the management blade There are two possible procedures for updating the firmware of the server blade BIOS and the server blade BMC Updating the server blade firmware from a USB floppy drive This procedure is described in the Operating Manual for the server blade see Related Publications on page 165 Updating the firmware of the server blade with TFTP see below Proceed as follows gt Install your TFTP server software and start it gt Download the TFTP update package BX600 S2_TFTP IMAGES_ lt version gt exe from the Fujitsu Siemens download server http www fujitsu siemens com support downloads html gt Extract the desired BIOS and or BMC firmware files to the root directory of the TFTP file system For information on the image file names see the readme file of the update package gt Check the LAN connection by pinging the relevant server blade Update the firmware of the server blade BIOS and BMC You have two options for doing this 1 In the management console Telnet select the TFTP Update submenu The update process is similar to the process via the management blade web user interface see below 60 PRIMERGY BX600 S2 Basic Unit Preparation for Use and Operation Updating BX600 System Components 2 In the web interface of the management bl
97. s The rails have a linear alignment option to also allow adjustment to different rack depths Extended cable management within the lateral rack area The following applies to rack systems from third party manufacturers PRIMERGY BX600 S2 Basic Unit 35 Installing the System in the Rack Installing the Hardware 3rd Party Rack Certain framework conditions must be fulfilled Installation dimensions see the dimensions shown in figure 5 on page 37 1 rack front 2 rack rear A rack depth comparison PRIMECENTER rack 940 1000 mm B rack width comparison PRIMECENTER rack 700 mm C clearance of the 19 inch installation level C1 front 19 inch installation level C2 rear 19 inch installation level D area for cable routing cable area depth and ventilation area for front panel and ventilation F right and left area for support systems PRIMERGY installation depth al front left support upright a2 front right support upright b1 rear left support upright b2 rear right support upright Please ensure that the security mechanism e g stopper or retention system on the server is working The rack support uprights must allow the rails to be screwed on at the front Frontally bolted rails The rails have with a linear alignment option to also allow adjustment to different rack depths No support for the cable management delivered with the mounting kit This cable management is customized for the Fujits
98. s document have been legally transferred to Fujitsu Technology Solutions Contact and support addresses will now be offered by Fujitsu Technology So lutions and have the format ts fujitsu com The Internet pages of Fujitsu Technology Solutions are available at http ts fujitsu com and the user documentation at http manuals ts fujitsu com Copyright Fujitsu Technology Solutions 2009 Hinweise zum vorliegenden Dokument Zum 1 April 2009 ist Fujitsu Siemens Computers in den alleinigen Besitz von Fujitsu bergegangen Diese neue Tochtergesellschaft von Fujitsu tr gt seit dem den Namen Fujitsu Technology Solutions Das vorliegende Dokument aus dem Dokumentenarchiv bezieht sich auf eine bereits vor l ngerer Zeit freigegebene oder nicht mehr im Vertrieb befindliche Produktversion Bitte beachten Sie dass alle Firmenbez ge und Copyrights im vorliegenden Dokument rechtlich auf Fujitsu Technology Solutions bergegangen sind Kontakt und Supportadressen werden nun von Fujitsu Technology Solutions angeboten und haben die Form ts fujitsu com Die Internetseiten von Fujitsu Technology Solutions finden Sie unter http de ts fujitsu com und Unter http manuals ts fujitsu com finden Sie die Benutzerdokumentation Copyright Fujitsu Technology Solutions 2009
99. s hot swap redundant fans 12 PRIMERGY BX600 S2 Basic Unit Introduction Features Server Management Server management is implemented via the supplied ServerView software and PDA Prefailure Detection and Analyzing technology from Fujitsu Siemens Computers PDA warns of system errors or overloading before they occur so that preventive measures can be taken ServerView allows the management of all PRIMERGY servers in the network via a central console Here ServerView supports the following functions e Remote startup Wake On LAN e Temperature monitoring ofthe CPU and the surrounding area e Watchdog timer for Automatic Server Reconfiguration and Restart ASR amp R in the event of memory modules or processors failing e Power monitoring e End of life monitoring of the fans with timely notification before a failure e Watchdog timer for operating system monitoring and application monitoring with ASR amp R Deployment software makes installing multiple servers fast and easy For further information see the corresponding documentation see Related Publications on page 165 Information on server management with ServerView is provided in the associated documentation see also Related Publications on page 165 ServerStart You can configure the server quickly and precisely with the ServerStart software provided User guided menus are available for installing the server operating systems Service and Support
100. s of the server blades in a configuration with ten 2 way server blades FC switch blade NET3 FC switch blade NET4 Server blade 8 Server blade 9 Server blade 10 Server blade 1 Server blade 2 Server blade 3 Server blade 4 Server blade 5 Server blade 6 Server blade 7 Figure 61 Fabric port assignment with 2 way server blades e When using the 12 port version the fabric ports of the server blades 6 1 and7 slots 9 and 10 are not available PRIMERGY BX600 S2 Basic Unit 109 Port Assignment FC Switch Blade Configuration with five 4 way server blades The illustration below shows the assignment of FC switch blades to the fabric ports of the server blades in a configuration with five 4 way server blades FC switch blade NET3 FC switch blade NET4 Server Server Server Server Server Blade 5 Blade 1 Blade 2 Blade 3 Blade 4 Figure 62 Fabric port assignment with five 4 way server blades e When using the 12 port version the fabric ports of server blade 4 slots 9 1 and 10 are not available 110 PRIMERGY BX600 S2 Basic Unit FC Switch Blade FC switch blade installation Configuration with a combination of 2 way server blades and 4 way server blades The illustration below shows the assignment of FC switch blades to the fabric ports of the server blades in a configuration with two 4 way server blades and six
101. signment with five 4 way server blades 120 PRIMERGY BX600 S2 Basic Unit FC Pass Thru Blade Exchanging an FC Pass Thru Blade 11 4 Exchanging an FC Pass Thru Blade CAUTION e Read the safety information and the information on handling electro static sensitive components in the section Components With Electrostatic Sensitive Devices on page 25 e The FC pass thru blade must always be installed in slots and NET3 first see page 117 Removing the FC pass thru blade 3 19 gt en mn EEE L Figure 74 Disengaging the FC pass thru blade gt Press the spring on the underside of the eject handle to unlock it PRIMERGY BX600 S2 Basic Unit 121 Exchanging an FC Pass Thru Blade FC Pass Thru Blade REES wT Figure 75 Disengaging the FC pass thru blade Swing the eject handle 1 of the FC pass thru blade in the direction of the arrow until the locking mechanism disengages and the blade is ejected a few centimeters Remove the FC pass thru blade from the slot 2 The FC pass thru blade is inserted using these instructions in reverse order 122 PRIMERGY BX600 S2 Basic Unit FC Pass Thru Blade Exchanging an FC Pass Thru Blade CAUTION If you remove the FC pass thru blade and do not replace it with a new one you must insert adummy module into the empty slot to ensure cooling to comply with the applicable EMC regulations regulations on elec
102. system can be upgraded with one additional switch blade CAUTION e Read the safety information and the information on handling electro static sensitive components in the section Components With Electrostatic Sensitive Devices on page 25 e LAN switch blades must always be installed in slots NET1 and NET3 first see page 90 PRIMERGY BX600 S2 Basic Unit 93 Installing a LAN Switch Blade Ethernet Switch Blades Removing the Dummy Module All unoccupied slots in the basic unit are fitted with dummy modules to ensure that the electromagnetic emission properties of the system are observed and that the system components are properly cooled If you wish to install a LAN switch blade you must first remove the dummy module from the corresponding slot i Figure 48 Removing the dummy module a green touch point gt Press the spring 1 on the underside of the handle a to unlock it Swing the handle a in the direction of the arrow 2 until the locking mechanism of the dummy module disengages 94 PRIMERGY BX600 S2 Basic Unit Ethernet Switch Blades Installing a LAN Switch Blade gt b Figure 49 Removing the dummy module a green touch point Remove the dummy module from the slot 2 CAUTION Keep the dummy module for future use If you remove the LAN switch blade and do not replace it with a new one you must reinstall the dummy module Installation
103. t Remove the fan from the unit 2 To mount a fan follow these instructions in the reverse order PRIMERGY BX600 S2 Basic Unit 153 16 Troubleshooting and Tips CAUTION Please note the safety instructions in the chapter Important Notes on page 21 If a fault occurs try to correct it as described inthis chapter inthe chapters for the components installed inthe documentation for the connected devices inthe help system of the individual programs If you do not manage to correct the problem proceed as follows gt Make a note of the steps and the circumstances that led to the fault Also make a note of any error messages displayed gt Switch OFF the defective server blade or the system gt Contact your customer service 16 1 System Power LED Remains Unlit The power LED see figure 15 on page 50 remains unlit after you have switched ON your system Wrongly connected power cables gt Make sure that the power cables are correctly connected to the system power supply units and to the mains socket strip of the rack see section Connecting the System to the Mains on page 46 Power supply overloaded gt Unplug the power cables from the insulated sockets of the power supply units gt Wait a few seconds and plug the power plugs into the insulated sockets again gt Switch ON your system PRIMERGY BX600 S2 Basic Unit 155 Front or Rear Identify Fault LED Blinks Amber
104. t DHCP Configure disable Time Zone i Management Agent Date Time 11 21 2003 13 46 01 Set Management Agent Timeout Sec 908 Agent System Info Management Agent Administrative URL http 10 90 90 20 80 Rutosati aliy Adjust Clock for Daylight Saving Changes disable gent Agent SNMP Agent Telnet Agent DNS Agent SHTP Agent NTP Agent NIC Duplex Mode Change Management Role To Slave r selection or type 0 to quit _ fison 50u CAPs MM Capus Print echo Figure 20 Management Agent Information menu Follow the steps below to make the management blade accessible via the LAN gt Select 1 to set the IP address of the management blade gt Select 2 to enter the network mask of your subnet gt Select 3 to enter the IP address of your gateway gt Select 18 to call up the Agent NTC Duplex Mode menu 58 PRIMERGY BX600 S2 Basic Unit Preparation for Use and Operation Management Blade Configuration The management blade LAN controller only runs at 10 Mbit sec Duplex mode must be defined manually via the Agent NTC Duplex Mode see figure 21 below HyperTerminalMB HyperTerminal lolx Ele Edit View Call Transfer Help Die i3 oll Execution Mode Full Mode 2 Setting Mode Full Mode Enter selection or type 0 to quit Connected 0 13 16 Wro 115200601 i WM Capture Figure 21 Agent NIC Duplex Mode menu gt Enter 2 if the preset duplex mode value needs to be alt
105. t Ethernet pass thru blade 3 Gigabit Ethernet pass thru blade 4 1 0 module dx 1 O module ts O module tex Figure 57 Port assignment to the Gigabit Ethernet I O modules with five 4 way server blades 9 3 Replacing an Ethernet Pass Thru Blade CAUTION e Ethernet pass thru blades must always be installed in slots NET1 and NETS first see page 101 An Ethernet LAN Pass Thru Blade is installed and removed in the same way as a LAN switch blade see section Installing a LAN Switch Blade on page 93 104 PRIMERGY BX600 S2 Basic Unit 10 Fibre Channel Switch Blade The 2 4 Gbit Brocade SilkWorm 4016 Fibre Channel switch blade hereinafter referred to as FC switch blade provides up to ten internal fabric ports to the server blades and up to six external fabric ports for fast and reliable connection to an SAN The FC switch blade automatically adapts to transfer rates of 1 up to 4 Gbit s With the BX600 S2 basic unit it offers transfer rates of 2 Gbit s internal and 4 Gbit s external A 10 100 Mbit s RJ45 connection is available for administration of the FC switch blade across aLAN All features of Brocade Fabric OS 5 0 4 the joint software platform for Brocade fibre channel switches are available as an operating system for the FC switch blade Administration of the FC switch blade is handled by Fabric Watch and Advanced Web Tools from Brocade Figure 58 Fibre Channel
106. tch blade failure LEDs to identify the defective unit gt If the switch blade is still indicated as defective exchange it see section Installing a LAN Switch Blade on page 93 156 PRIMERGY BX600 S2 Basic Unit Troubleshooting and Tips System Switches Itself OFF 16 3 System Switches Itself OFF Server management has detected an error gt Inthe ServerView program check the error list or the error log file with the SCU utility and try to eliminate the error see manual PRIMERGY BX Blade Server Systems RemoteView Management Blade User Interface Description 16 4 Screen Remains Dark Monitor is switched OFF gt Switch ON your monitor Screen has gone blank gt Press any key on the keyboard or gt Deactivate screen blanking screen saver Enter the appropriate password Brightness control is set to dark gt Setthe brightness control to light For detailed information see the operating manual supplied with your monitor Monitor power cable or data cable not connected gt Switch OFF the monitor Check whether the power cable is properly connected to the monitor and to the grounded insulated socket Check whether the data cable is properly connected to the system and monitor if it is plugged in with a connector gt Switch on the monitor PRIMERGY BX600 S2 Basic Unit 157 Flickering Stripes on the Monitor Screen Troubleshooting and Tips 16 5 Flickering Stripes on the M
107. tem switches itself OFF Error Correcting Code 12 ESD devices sensitive to electrostatic discharge 25 ESD sensitive devices 25 Ethernet pass thru blade 99 connection panel 100 Control panel 100 control panel 100 Port assignment 101 slot 101 exchanging Battery 128 FC pass thru blade 121 Management blade 130 external devices connecting 45 158 159 157 F fan module front 12 149 rear 12 149 fan unit replacing 151 fault defective drive 159 display drifts 158 flickering stripes on screen 158 floppy disk cannot be read written 159 incorrect date incorrect time 159 159 no display on screen 158 no mouse pointer 158 screen remains dark 157 server blade does not boot system switches itself OFF FC pass thru blade 113 connection panel 114 control panel 114 exchanging 121 159 157 Port assignment 117 slot 118 FC switch blade Control panel 106 Installing 111 Port assignment 108 FCC statement 26 Fibre Channel pass thru blade 113 SFP module 115 Switch blade 105 flash EPROM 13 floppy disk cannot be read written 159 H height units 38 hot swap fan module 12 management blade 12 power supply unit 12 server blade 12 switch blade 12 l indicators power supply unit system 50 information additional 9 installation steps overview 19 146 PRIMERGY BX600 S2 Basic Unit Index installing dummy module 76 FC switch blade 111 intherack 35 LAN switch blade 93 95 system 35 K KVM blade 133
108. the basic configuration the PRIMERGY BX600 S2 base unit contains two hot swap power supply units PSU1 and PSU2 in figure 88 The power supply units adapt automatically to any voltage within the range 200 V 240 V Em ag Figure 88 PRIMERGY BX600 S2 basic unit power supply units To provide a redundant power supply a third or fourth power supply unit can be installed PSU3 and PSU4 in figure 88 If one of the four power units fails the other two three units will ensure the unit continues to operate normally The defective power supply unit can be replaced while the unit is still running hot swap Please make sure that each of the power supply units is connected to a i different phase This will provide you with additional phase redundancy for high availability configurations If one phase has failed the power supply units connected to the other phases keep active You can get full phase redundancy with up to three power supply units With four power supply units two of them are to be connected to one phase see also Related Publications on page 165 PRIMERGY BX600 S2 Basic Unit 139 Power Supply Units Power Supply Concept Phase redundancy is possible in regions where a single phase provides 200 240V in other regions with lower single phase voltage two phases must be coupled and complete phase redundancy thus is not possible The unoccupied PSU slots are fitted with dummy modules t
109. to port A of the installed fibre channel daughter cards The FC switch blade in the NET4 slot is connected to port B of the installed fibre channel daughter cards i 1 000 000 83 EN Figure 60 Slots for FC switch blades The installation of two FC switch blades enables redundant fibre channel connections to be provided for the server blades CAUTION e FC switch blades must always be installed in slot NET3 first This ensures that port A of the FC daughter cards is connected if redundant fibre channel connections are not used e If Gigabit Ethernet daughter cards are installed in the server blades LAN switch blades see page 81 or Ethernet pass thru blades see page 99 must be installed in slots NET3 and NET4 Simultaneous operation of Ethernet blades and fibre channel blades in slots NET3 and NET4 is not permitted The configuration examples below show the assignment of the FC daughter card ports to the LAN switch blades in slots NET3 and NET4 108 PRIMERGY BX600 S2 Basic Unit FC Switch Blade Port Assignment Configuration with ten 2 way server blades The illustration below shows the assignment of FC switch blades to the fabric port
110. tor green LED Glows green Selected for identification by the management blade Blinks green Error occured The information necessary for configuring and operating the Gbit Ethernet LAN switch blade SB9 6x1Gbit can be found in the manual PRIMERGY BX Blade Server Systems LAN Router and Switch Blade User Interface Description see Related Publications on page 165 PRIMERGY BX600 S2 Basic Unit 83 LAN Switch Blade SB9 6x1 Gbit 2x10 Gbit Ethernet Switch Blades 8 2 Gbit Ethernet LAN Switch Blade SB9 6x1 Gbit 2x10 Gbit The Gbit Ethernet LAN switch blade SB9 6x1 Gbit 2x10 Gbit supports layer 2 3 4 functionality and offers the following connections 10 internal 1Gbit downlink ports to the server blades 6 external 1Gbit uplink ports via RJ45 connectors 2external 10 Gbit uplink ports via XFP module and corresponding fibre optic cable and CX4 connector and corresponding copper cable Operating and Indicator Elements Figure 41 Gbit Ethernet LAN switch blade SB9 6x1 Gbit 2x10 Gbit 1 6 1 Gbit uplink LAN connectors with two integrated LAN status LEDs each LED A LAN active indicator bicolor LED Glows amber Port link at 1 Gbit s Glows green Port link at 100 Mbit s Dark Port link at 10 Mbit s LED B LAN link indicator yellow LED Glows yellow Network link Glows yellow Network activity Dark No network link or port disabled 7 10 Gbit XFP connector 8 10 Gbit
111. transport 27 server blade adding 76 does not boot 159 dummy module 76 server management 13 ServerStart 13 ServerView 13 supported functions 13 SFP module 115 standards 15 sticker 29 Stromversorgung Netzteil 11 12 supervisor password 69 Switch blade Fibre Channel 105 LAN 94 Switch Blade Cisco Catalyst 3040 86 88 SB9 10 Gbit Multimode 84 SB9 6x1Gbit 82 switch OFF time define 54 switch ON time define 54 switching OFF system 53 switching ON system 53 system connecting mains voltage 46 front 50 height units 38 indicators 50 installing 35 operating elements 50 power supply 139 rear 52 routing cables 43 switches itself OFF error 157 switching OFF 53 switching ON 53 unpacking 34 ventilation 149 system power LED remains unlit 155 T target group 8 technical data 15 time incorrect 159 transport damage 34 U unpacking system 34 user password 69 V ventilation fan in power supply unit 12 149 fan module 12 149 system 149 ventilation clearance 16 W weight 16 PRIMERGY BX600 S2 Basic Unit Re FUJITSU Information on this document On April 1 2009 Fujitsu became the sole owner of Fujitsu Siemens Compu ters This new subsidiary of Fujitsu has been renamed Fujitsu Technology So lutions This document from the document archive refers to a product version which was released a considerable time ago or which is no longer marketed Please note that all company references and copyrights in thi
112. tromagnetic compatibility and for fire protection Make sure that the dummy module engages in the slot correctly Figure 76 FC pass thru blade dummy module PRIMERGY BX600 S2 Basic Unit 123 12 Management Blade The PRIMERGY BX600 S2 basic unit accommodates two hot swappable redundant management blades with an integrated management solution for complete remote administration of the system The management blades provide convenient user interfaces A web il interface is available as well as aconsole menu interface using the Telnet protocol For a detailed description please see the manual RemoteView Management Blade User Interface Description The management blades have separate 10 Mbit LAN connections to maintain accessibility to the system even with the standard traffic network connections down The slots for the management blades are located on the rear of the basic unit figure 77 gas ge Management blade 2 kcal x Management blade 1 Figure 77 Management blade slots il Important note Management blades to be used in the PRIMERGY BX600 S2 base unit must have order number A3C40073243 Compatibility with the S1 model management blade used in the PRIMERGY BX600 base unit is not provided PRIMERGY BX600 S2 Basic Unit 125 Control and Connection Panel Management Blade 12 1 Control and Connection Panel Figure 78 Management blade control
113. u Siemens Computers PRIMECENTER rack Climatic conditions For the ventilation of the installed server there must be sufficiently large gaps for air intake at the front of the rack and air discharge at the back of the rack 36 PRIMERGY BX600 S2 Basic Unit Installing the Hardware Installing the System in the Rack In principle the ventilation concept allows for the necessary cooling through horizontal self ventilation of the installed devices air flow from the front to the rear Power supply For installation in 3rd party racks you must ensure that appropriate socket strips are present ASYAW Idd ww GLe OLZ C 450 mm 1 u B Figure 5 Mechanical conditions PRIMERGY BX600 S2 Basic Unit 37 Installing the System in the Rack Installing the Hardware 4 3 1 Mounting the Assembly Kit Mounting the server in the PRIMECENTER DataCenter Rack requires the following parts two support brackets two carrier rails assembled 12 plug washers figure 7 on page 39 and screws For general information see the technical manual for the relevant rack see also Related Publications on page 165 To mount the PRIMERGY BX600 S2 basic unit in the rack you must first mount two support brackets on the rear left support upright of the rack The first one must be mounted level with the lower edge of the device wh
114. vated by setting a supervisor password in the Security menu In addition the Press F2 for Setup message in the Security menu can be suppressed This message is then no longer displayed while the server s startup routine is in progress Preventing Unauthorized System Access This protection mechanism can be activated by setting a user password in the Security menu Preventing Unauthorized Boot Process This protection mechanism can be activated by setting a password on boot in the Security menu PRIMERGY BX600 S2 Basic Unit 69 7 Server Blades This chapter describes how to install and uninstall server blades and server blade dummy modules in the PRIMERGY BX600 S2 basic unit and what you need to be aware of when doing this The information necessary for installing and operating the various server blade models can be found in separate manuals see Related Publications on page 165 When you install a server blade in the basic unit an important factor is the height Figure 28 shows a 2 way server blade which occupies one slot in the basic unit Figure 28 PRIMERGY BX620 S3 S4 2 way server blade PRIMERGY BX600 S2 Basic Unit 71 Server Blades The 4 way server blade is twice the height and occupies two slots figure 29 Figure 29 PRIMERGY BX630 scalable server blade 4 way configuration 72 PRIMERGY BX600 S2 Basic Unit Server Blades Installation Sequence 7 1 Installatio
115. washers in the holes of the front left support upright at the marked attachment points adjust the rail length 2 and while holding the rail in place fasten it with three screws 4 Pull the carrier rail of the rack mounting kit forward as far as possible in the direction of the arrow 2 Fasten the six screws for adjusting the rail length 1 Repeat the procedure for the second rail Note that for this rail no support bracket is necessary PRIMERGY BX600 S2 Basic Unit 39 Installing the System in the Rack Installing the Hardware 4 3 2 Mounting Removing the Basic Unit CAUTION For safety reasons at least two people are required to mount or remove the PRIMERGY BX600 S2 basic unit because of its weight and size Please note the relevant safety instructions in section Notes on Installing in the Rack on page 28 Before lifting the basic unit into the rack remove server blades fan units and power supplies from the basic unit to reduce weight Figure 8 Mounting the basic unit gt Note the slot assignment of the server blades so that you can insert them correctly again once you have lifted the basic unit into the rack Remove server blades fan units and power supplies from the system unit to reduce weight for assembly instructions see section Adding a Server Blade to the Basic Unit on page 76 section Replacing a Power Supply Unit on page 142 and section Replacing the
Download Pdf Manuals
Related Search
Related Contents
Transfere - CONRAD Produktinfo. Tecumseh VSAG475ZXT Performance Data Sheet Lincoln Electric 305LPG User's Manual SERVICE MANUAL CMT6118 IDE Controller and Compact Flash Carrier with Floppy Valueline DVI-I/DVI-I + HDMI, 0.20m Manual de instrucciones Mode d`emploi - Air France Magazine Sartorius Combics 3 脱気モジュール用COT-5 COT−5 取扱説明書 Copyright © All rights reserved.