1. Circuit breaker has tripped due to excessive load Action Needed Remove one piece of equipment from the ETA C15D and push the breaker reset tab located on the front panel Note We suggest first locating the highest power consumer such as a power amplifier and disconnecting or turning down that unit If the ETA C15D breaker continues to trip relocating some of the gear may be required Issue No power to the AC outlets Abnormal Voltage indicator is illuminated the Volt Meter is Flashing and you hear a buzzer from the unit Possible Cause The AC Mains Voltage exceeded 132VAC or the voltage dropped below 101VAC Action Needed Measure the AC mains before the ETA C15D If the voltage is between 117VAC and 123VAC you may proceed to reset the ETA C15D by restarting the start up sequence Note It is important to have all equipment that was connected to that AC Mains Line to be inspected for proper operation If the problem persists contact your local power company for the cause of unstable AC line conditions Issue Abnormal LED Flashing and you have power to all outlets Possible Cause The AC Mains Voltage exceeded 128VAC or the voltage dropped below 107VAC Action Needed The ETA C15D must be reset to turn off the LED Measure the AC mains before the ETA C15D If the voltage is between 117VAC and 123VAC you may proceed to reset the AP C15D by cycling the Power Switch Off On Note It is important to have all equipment that was connec
2. LED is illuminating it is important to have all equipment that was connected to that AC Mains Line be inspected for proper operation AC Mains Abnormal Voltage Indicator This LED flashes under several AC Mains fault situations listed below Normal operating voltages for AC Mains voltage is considered to be between 108VAC and 127VAC Any voltages exceeding those parameters are considered a risk to damage equipment plugged into the AP C15D High AC Line Mains The Abnormal Voltage LED will flash between 128VAC 132VAC indicating possible damage may occur to equipment due to high AC Mains voltage The ETA C15D outlets will remain active but the LED will stay flashing even if the voltage returns to a normal operating range To stop the LED from flashing the Power switch must be cycled Off Note It is recommended prior to proceeding to have the AC Mains inspected by an electrician Low AC Line Mains The Abnormal Voltage LED will flash between 101VAC 107VAC indicating possible damage may occur to equipment due to low AC Mains voltage The ETA C15D outlets will remain active but the LED will stay flashing even if the voltage returns to a normal operating range To stop the LED from flashing the Power Switch must be cycled Off Note It is recommended prior to proceeding to have the AC Mains inspected by an electrician Extreme High AC Line Mains If the AC Mains reach 133VAC the EVS Extreme Voltage Shutdown circuit will be
3. Power Conditioner Leading by Design N LIMITED WARRANTY All products manufactured by ETA Systems are warranted to the original dealer installer industrial or commercial purchaser to be free from defects in material and workmanship and to be in compliance with our published specifications if any This warranty shall extend from the date of purchase for a period of one year Additionally fuses and lamps carry no warranty ETA Systems will solely at its discretion replace at no charge or repair free of charge defective parts or products when the product has been applied and used in accordance with our published operation and installation instructions We will not be responsible for defects caused by improper storage misuse including failure to provide reasonable and necessary maintenance accident abnormal atmospheres water immersion lightning discharge or malfunctions when products have been modified or operated in excess of rated power altered serviced or installed in other than a workmanlike manner The original sales invoice should be retained as evidence of purchase under the terms of this warranty All warranty returns must comply with our returns policy set forth below When products returned to ETA Systems do not qualify for repair or replacement under our warranty repairs may be performed at prevailing costs for material and labor unless there is included with the returned product s a written request for an estimate of repair
4. is very fast and can suppress unwanted energy within a nanosecond while sustaining the suppression up to 2 milliseconds thus ensuring virtually trouble free protection High and low AC Main line voltages are another major contributor to equipment failures High line can also be known as surges Surges usually are a slower steady state rise in voltages ranging from 128VAC and up They can be caused from fluctuations in the utility company s power lines or industrial equipment turning on and off and is on the same power leg of the building s incoming AC Low line is also known as brownouts This happens when the AC Mains drops below 107VAC Most of the time this is caused by the utility company not being able to supply enough power during heavy utility consumption time periods such as heat waves Long transmissions could be another factor of voltage drops in AC lines The ETA C15D will not only inform you if one of these conditions occurs but under extreme variances in the AC Mains it will shut off the power to the equipment off The Abnormal Voltage indicator on the front panel will flash if the AC Mains is between 101VAC and 107VAC or 128VAC and 132VAC This is to inform you that a surge occurred and may have damaged voltage sensitive equipment If an extreme voltage swing occurs below 101VAC or above 132VAC the ETA C15D Extreme Voltage Shutdown EVS protection circuit will automatically activate and turn all outlets off until it is manual
5. triggered to shut off the AC outlets while activating the Abnormal Voltage LED The red LED will illuminate steady and the AC Mains Voltage Meter will flash OL Overload indicating possible damage may occur to the equipment plugged into the ETA C15D due to high AC Mains voltage The ETA C15D outlets will remain off until the Power Switch is cycled Off Note It is recommended prior to proceeding to have the AC Mains inspected by an electrician Extreme Low AC Line Mains If the AC Mains lowers to 101VAC the EVS Extreme Voltage Shutdown circuit will be triggered to shut off the AC outlets while activating the Abnormal Voltage LED The red LED will illuminate steady and the AC Mains Voltage Meter will flash OL Overload indicating possible damage may occur to the equipment plugged into the ETA C15D due to low AC Mains voltage The ETA C15D outlets will remain off until the Power Switch is cycled Off Note It is recommended prior to proceeding to have the AC Mains inspected by an electrician 1601 Jack McKay Blvd Ennis Texas 75119 U S A Telephone 800 321 6699 Fax 800 996 3821 a ETAsys com Specifications are subject to change without notice ETA ETA C15D SYSTEMS Power Conditioner Leading by Design N REAR PANEL FEATURES gm OJO O 000 1 AC Mains Input Connect the 9 3m power cord to a 15A 120VAC outlet to provide power to the ETA C15D 2 AC Filtered Outlets The five AC o
6. EN THE DEVICE IS IN USE e Never place heavy objects on the product causing it to fall and or break resulting in personal injury and property damage In addition the product itself may fall and cause injury and property damage e Contact ETA Systems for instructions on cleaning the inside of the unit Large accumulations of dust inside the unit may result in heat buildup and fire e Ensure that the power supply plug is securely plugged into the wall outlet Never allow dust to accumulate on the power plug or inside the wall outlet e When cleaning the unit or the unit is not to be operated for an extended period unplug the power cord from the wall 1601 Jack McKay Blvd Ennis Texas 75119 U S A Telephone 800 321 6699 Fax 800 996 3821 enn ETAsys com Specifications are subject to change without notice ETA C15D E TA Power Conditioner SYSTEMS Leading by Design INTRODUCTION Thank you for purchasing the ETA Systems ETA C15D AC Power Conditioner The ETA C15D has been designed to meet most installation requirements for AC power distribution and equipment power protection The 15A compact 1RU unit AC Mains Voltage can be monitored via the front panel from the precision Digital Volt Meter To light your rack the ETA C15D has incorporated a front panel pull out dimmable LED tube light The rear of the rack can be illuminated by an optional Atlas Power 16 gooseneck LED lamp AP GNL18 connected via an XLR
7. ETA C15D E TA Power Conditioner SYSTEMS Leading by Design ETA SYSTEMS Leading by Design ETA C15D Power Conditioner 1601 Jack McKay Blvd Ennis Texas 75119 U S A Telephone 800 321 6699 Fax 800 996 3821 2 ETAsys com Specifications are subject to change without notice ETA ETA C15D SYSTEMS Power Conditioner Leading by Design N TABLE OF CONTENTS mportant Safety INStrUCtIONS oooocociccnnncccioccnocccooncconnconnconnnnnonn conc cnn n non n nan EAEE EN EAEE EN EENEN nr narran rra 3 OTOMANO Saat sch ace dN eee e 5 ey REGUUNCS 21 stern a 2a o a il illa alto ss 6 PAD BIICALON S lil do a solace an tenetaetadss 6 O 6 O sunils pases EEE E EAE a sor E ada 8 Stallone iio 8 AC Power Cord Retainer O diia 9 MOU ISSO OUI tn nd delirio di 10 SPECIMICAIN Sc O R a 11 AVAVA T a AYAAN AEE E EAE E E EE E laa cadade 12 1601 Jack McKay Blvd Ennis Texas 75119 U S A Telephone 800 321 6699 Fax 800 996 3821 a ETAsys com Specifications are subject to change without notice ETA C15D E TA Power Conditioner SYSTEMS Leading by Design IMPORTANT SAFETY INSTRUCTIONS oN Oar WD 10 Ti 12 13 14 15 16 Vd 18 The lightning flash with arrowhead symbol within an CAUTION equilateral triangle is intended to alert the user to the presence of uninsulated dangerous voltage within the RISK
8. Fax 800 996 3821 i ee ETAsys com Specifications are subject to change without notice ETA ETA C15D SYSTEMS Power Conditioner Leading by Design N NN WARNING WHEN THE DEVICE IS IN USE e To prevent electric shock do not remove the product cover as there are high voltage components inside Refer all servicing to ETA Systems e Should any of the following irregularities occur during use immediately switch off the power disconnect the power cord from the AC outlet and contact ETA Systems Do not to attempt to continue operation with the product as this may cause fire or electric shock e Smoke or strange smell coming from the unit e If the product falls or the case is damaged e f water or any metallic objects falls into the product e f the power supply cord is damaged in any way e If the unit is malfunctioning e Do not insert or drop metallic objects or flammable materials into the ventilation holes of the product s cover as this may result in electric shock or fire e Do not place any containers with liquid or metallic objects on the top of the product If any liquid spills into the unit fire or electric shock may result ever operate this product or touch the power supply cord during an electrical storm electric shock may result ever exceed the power rating on the product when connecting equipment Fire and or property damage may result e Operate the product only with the voltage specified on th
9. OF ELECTRIC SHOCK product s enclosure that may be of sufficient magnitude DO NOT OPEN E a to constitute a risk of electric shock to persons ATTENTION eee ee CAUTION The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance servicing instructions in the literature accompanying the product WARNING TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK DO NOT EXPOSE THIS APPLIANCE TO RAIN OR MOISTURE Read these instructions Keep these instructions Heed all warnings Follow all instructions Do not use this device near water Clean only with dry cloth Do not block any ventilation openings Install in accordance with the manufacturer s instructions Do not install near any heat sources such as radiators heat registers stoves or other device including amplifiers hat produce heat Do not defeat the safety purpose of the polarized or grounding type plug A polarized plug has two blades with one wider than the other A grounding type plug has two blades and a third grounding prong The wide blade or the third prong are provided for your safety If the provided plug does not fit into your outlet consult an electrician for replacement of the obsolete outlet Protect the power cord from being walked on or pinched particularly at plugs convenience receptacles and the point where they exit from the device Only use attachments accessories specified by t
10. costs before any non warranty work is performed In the event of replacement or upon completion of repairs return shipment will be made with the transportation charges collect EXCEPT TO THE EXTENT THAT APPLICABLE LAW PREVENTS THE LIMITATION OF CONSEQUENTIAL DAMAGES FOR PERSONAL INJURY ETA SYSTEMS SHALL NOT BE LIABLE IN TORT OR CONTRACT FOR ANY DIRECT CONSEQUENTIAL OR INCIDENTAL LOSS OR DAMAGE ARISING OUT OF THE INSTALLATION USE OR INABILITY TO USE THE PRODUCTS THE ABOVE WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES INCLUDING BUT NOT LIMITED TO WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ETA Systems does not assume nor does it authorize any other person to assume or extend on its behalf any other warranty obligation or liability This warranty gives you specific legal rights and you may have other rights which vary from state to state SERVICE Should your ETA C15D require service please contact the ETA Systems warranty department at 1 877 689 8055 ext 277 to obtain an RA number ETA Systems Tech Support can be reached at 1 800 321 6699 Visit our web site at www ETAsys com to see other ETA Systems products ETA SYSTEMS Leading by Design 2012 ETA Systems All rights reserved All other trademarks are the property of their respective owners ETA003563 RevB 3 12 1601 Jack McKay Blvd Ennis Texas 75119 U S A Telephone 800 321 6699 Fax 800 996 3821 12 ETAsys com S
11. des in Spike Clamping Voltage ax Spike Clamping Voltage ax Spike Clamping Resp Time Spike Clamping Voltage 100A aximum Surge Current Energy Rating 2ms oise Attenuation EMI RFI Temperature Range Humidity Range Mechanical Chassis Finish Mounting Dimensions Weight ETA C15D E TA Power Conditioner SYSTEMS N Leading by Design Power Conditioner amp Suppressor 15A ETL UL 60065 Standard 2 Unswitched 1 Pull Out LED with Dimmer Switch Rocker 15A Resettable Thre Digits Digital AC Power On Abnormal Voltage AC Fault Breaker Open Wiring Fault 8 Total 6 Filtered 1 High Power Non Filtered 1 Unswitched XLR Socket to Provide 12VDC for Optional AL GNL18 Gooseneck Lamp Two Position On Off 9 3 Meters 14 gauge 15 amps 12 watts 102 132VAC Trigger at 133VAC 1ms typically Trigger at 101VAC 1ms typically 1 5VAC DCS Dual Clamping Suppression Circuitry on Incoming AC Mains and Each Section Output 460 VRMS Q 3 0004 6kV 1 nanosecond 1250Vp for 20us 6 500A 2000 Joules 10dB 10 kHz 40dB 100 kHz 100dB 10 MHz 5 to 35 C 5 to 95 R H Black Rack Mount 19 1 RU Height 1 75 44 45mm x Width 19 482 6mm x Depth 8 5 548 64mm 7 6 lbs 3 45kg 1601 Jack McKay Blvd Ennis Texas 75119 U S A Telephone 800 321 6699 Fax 800 996 3821 11 ETAsys com Specifications are subject to change without notice ETA ETA C15D SYSTEMS
12. e unit Fire and or electric shock may result if a higher voltage is used e Do not modify kink or cut the power cord Do not place the power cord in close proximity to heaters and do not place heavy objects on the power cord including the product itself doing so may result in fire or electrical shock e Ensure that the safety ground terminal is connected to a proper ground Never connect the ground to a gas pipe as a catastrophic disaster may result e Be sure the installation of the product is stable avoid slanted surfaces as the product may fall and cause injury or property damage CAUTION WHEN INSTALLING THE PRODUCT e Installation of this product must be done by a certified electrician for a permanently connected apparatus provided neither with an all pole mains switch nor an all pole circuit breaker A readily accessible disconnect device shall be incorporated in the building installation power wiring The installation shall be carried out in accordance with all applicable installation rules in accordance with all applicable federal state and local laws regulations and safety codes and ordinances e Never install this product in humid or dusty locations nor in direct sunlight near sources of heat or in areas where sooty smoke or steam are present Fire and electric shock may result e Keep all sides of the unit at least 3 away from objects that may obstruct air flow to prevent the unit s internal temperature rise CAUTION WH
13. he manufacturer Use only with the cart stand tripod bracket or table specified by the manufacturer or sold with the device When a cart is used use caution when moving the cart device combination to avoid injury from tip over This product is equipped with a three wire grounding type plug a plug having a third grounding pin This plug will only fit into a grounding type power outlet This is a safety feature If you are unable to insert the plug into the outlet contact your electrician to replace your obsolete outlet Do not defeat the safety purpose of the grounding type plug Unplug this device during lightning storms or when unused for long periods of time Refer all servicing to qualified service personnel Servicing is required when the device has been damaged in any way such as power supply cord or plug is damaged liquid has been spilled or objects have fallen into the device the device has been exposed to rain or moisture does not operate normally or has been dropped WARNING To reduce the risk of fire or electric shock this device should not be exposed to rain or moisture and objects filled with liquids such as a vase should not be placed on this device To completely disconnect this equipment from the mains disconnect the power supply cord plug from the receptacle The mains plug of the power supply cord shall remain readily operable 1601 Jack McKay Blvd Ennis Texas 75119 U S A Telephone 800 321 6699
14. l system use z2 x 1 Placement within a rack is not critical but the rack should be within 6 of a dedicated 15A AC outlet Always make sure the 15A outlet is properly inspected by a certified electrician prior to connecting the ETA C15D Below are a few installation tips e After plugging the ETA C15D into a 15A AC Mains outlet inspect the Wiring Fault LED for illumination The LED should not be on e Inspect the equipment that is to be plugged into the ETA C15D to ensure it does not exceed 15A total amperage draw e Divide the equipment into two categories Pick the outlets that match the outlets equipment use 1601 Jack McKay Blvd Ennis Texas 75119 U S A Telephone 800 321 6699 Fax 800 996 3821 mgs ETAsys com Specifications are subject to change without notice ETA C15D E TA Power Conditioner SYSTEMS Leading by Design AC POWER CORD RETAINER SYSTEM Your ETA Systems product comes with an AC Mains Power Cord Retainer System This system prevents the power cord from being removed without the use of a screwdriver Follow these steps for installation Note Installation of this product must be done by a certified electrician for a permanently connected apparatus provided neither with an all pole mains switch nor an all pole circuit breaker A readily accessible disconnect device shall be incorporated in the building installation power wiring The installation shall be carried out in accordance with a
15. ll applicable installation rules in accordance with all applicable federal state and local laws regulations safety codes and ordinances 1 Locate the 6 32 screw retainer clip and zip tie 4 Wrap the zip tie around the power cord as shown in Figure 4 2 Locate the AC wall outlet that will be used to power the de Atlas Power product Remove the center screw securing the y cover plate to the AC outlet 2 A Figure 4 ay gt Y Mi 5 Feed the end of the zip tie through the retainer and pull tightly Figure 1 to secure Note Some adjustment of the retainer may be needed in order to properly align it as shown in Figure 6 3 Place the screw through the retainer clip and insert into the cover plate making sure to securely tighten Inset the zip tie through the retainer clip slots as shown in Figure 3 1A Y Figure 5 Figure 6 a a A 6 Cut the excess zip tie off as shown in Figure 7 Figure 2 Figure 3 Figure 7 1601 Jack McKay Blvd Ennis Texas 75119 U S A Telephone 800 321 6699 Fax 800 996 3821 9 ETAsys com Specifications are subject to change without notice ETA ETA C15D SYSTEMS Power Conditioner Leading by Design N TROUBLESHOOTING GUIDE Issue Wiring Fault LED is illuminated Possible Cause AC Mains outlet is wired incorrectly Action Needed Contact a certified electrician to inspect the building s wiring Issue No power to the AC outlets Possible Cause
16. ly reset The ETA C15D offers intelligent power management control along with noise filtering and spike surge protection making it the most compact effective power management protection system on the market today 1601 Jack McKay Blvd Ennis Texas 75119 U S A Telephone 800 321 6699 Fax 800 996 3821 ETAsys com Specifications are subject to change without notice N ETA ETA C15D SYSTEMS Power Conditioner Leading by Design KEY FEATURES 10 Total Outlets Are Provided 8 Rear Panel Outlets 2 Front Panel and 1 Rear Panel Unswitched Convenience Outlets RFI Noise Filtering to Reduce Radio Frequency Interference EMI To Reduce Electromagnetic Interference Dual Clamping Spike amp Surge Suppression DCS Circuitry Front Panel Digital AC Mains Voltmeter LED Indication of Reversed Live and Neutral Wiring Abnormal AC Line Voltage Indicator for Voltages Between 101V 107V or 128V 132V Extreme Voltage Shutdown EVS Below 101V or Above 132V AC Line Circuit Breaker Protection 15A Indicated by Breaker Open Indicator Front Mounted Pull out LED Light With 2 Position Dimmer Rear Mounted XLR Connector for 12VDC LED Lamp APPLICATIONS The ETA C15D was designed to be flexible with features that allow it to be used in a variety of applications The ETA C15D can be used solely for protection against lightning strikes or voltage surges or for AC Mains Voltage Monitoring If fuzzy video or frequent
17. pecifications are subject to change without notice
18. static pops occur the AC power conditioning will eliminate or reduce those inconveniences The following are just a few examples of applications the ETA C15D can be used Unswitched Outlets are protected by the surge protection circuitry but will not be shut off by the EVS circuit 2 AC Mains Breaker The 15A rated breaker will open if the combined draw of all AC outlets exceeds 15A Note The breaker is designed to exceed its rating for a short period of time If the breaker is tripped you must first remove the load from the ETA C15D Restaurants Houses of Worship Schools Home Theaters Office Buildings Sports Bars FRONT PANEL FEATURES O 060 and then push to reset Power Switch To turn the ETA C15D on or off press the switch to the ON or OFF position 4 Pull Out Light The LED light is designed to be pulled out when needed Pull Out Light Dimmer Switch Use this control for the Pull Out Light Settings include an Off position and two brightness settings Low and High when On 1601 Jack McKay Blvd Ennis Texas 75119 U S A Telephone 800 321 6699 Fax 800 996 3821 rs Specifications are subject to change without notice QO 1 Unswitched AC Outlet The two 120VAC outlets are always live when the ETA C15D power cord is plugged into an AC mains power source and voltage is present Note The AC mains power switch does not affect the Unswitched AC Outlets The ETAs
19. style socket LED lamps are far superior in longevity along with heat reduction when compared to traditional incandescent lamps and the XLR base mounts offer a better connection point over commonly used BNC type bases The ETA C15D features noise filtering for unwanted Radio Frequency Interference RFI that is commonly introduced into the AC lines by nearby radio transmitters or wireless products EMI filters are incorporated to reduce noise from Electromagnetic Interference EMI from such items as electric motors and switching power supplies The benefit of these filters can be seen on video products or audibly by reducing static pops and external signal interference Unstable AC Mains voltage is one of the main reasons for equipment failure AC Spikes or Transients are commonly caused by lightning storms or utility power plant grid switchovers The amount of energy that can be injected into the power system can be immense with voltages reaching 6kV or amperage peaks of 3000A These spikes are very fast and usually only last for a very short period of time To protect against this potential problem the ETA C15D features Dual Clamping Suppression technology DCS If a spike intrudes the AC system the ETA C15D incoming AC Mains has special suppression circuitry to eliminate the unwanted energy and in the unlikely event of any energy getting pass the first stage each output section has redundant DCS circuitry clamping the unwanted energy This circuitry
20. ted to that AC Mains Line inspected for proper operation If the problem persists contact your local power company for the cause of unstable AC line conditions Issue AC Fault LED is Flashing a buzzer is sounding and you have no power at any outlets Possible Cause Although the Dual Clamping Suppression DCS circuit virtually assures protection from most transient voltage spikes and surges nature has a way of occasionally creating electrical forces that are beyond the capabilities of any device to absorb without some degree of damage In the rare instance that this occurs the DCS circuit has been damaged during the suppression Action Needed If this happens the ETA C15D will shut off and the unit will need to be repaired or replaced It is important to have all equipment that was connected to that AC Mains Line inspected for proper operation 1601 Jack McKay Blvd Ennis Texas 75119 U S A Telephone 800 321 6699 Fax 800 996 3821 10 ETAsys com Specifications are subject to change without notice ETA C15D SPECIFICATIONS Type Load Rating Safety Listing Front Panel AC Outlets Lights Activation Switch Circuit Breaker AC Mains Voltmeter Indicators Rear Panel AC Outlets LED Light Socket LED Light Switch AC Mains Power Cord Technical Data Current Rating Power Consumption Operating Voltage High Voltage Surge Protection Low Voltage Surge Protection Voltmeter Accuracy Spike Protection Mo
21. utlets are Live when the power switch is activated These outlets are recommended for products such as Computers Modems Routers DSP Processors Cable SAT DVD or CRT TVs These outlets have a special filter circuit that is optimized to reduce interference to your Digital and Analog components The total maximum draw for this section is 10A and the total current draw for the ETA C15D is 15A 3 AC High Power Outlet This outlet is designed to deliver maximum current to power hungry components like amplifiers and projectors It does not harm low power consuming components when connected to this outlet 4 Unswitched AC Outlet This 120VAC outlet is always live when the ETA C15D power cord is plugged into an AC mains power source and voltage is present If voltage is present at the outlets it will be displayed on the AC Mains Meter Note The AC mains power switch does not affect the Unswitched AC Outlets The Unswitched Outlets are protected by the surge protection circuitry but will not be shut off by the EVS circuit 5 XLR Light Socket A 12VDC XLR light socket provides power for the optional AL GNL18 light 6 Light Socket Power Switch This switch turns the XLR light socket On Off Installation Before installing we strongly suggest you read the entire manual to ensure you benefit from all the features of the ETA C15D The ETA C15D can be placed on a shelf or rack mounted in a standard 19 width rack When mounting to a rack rai
22. ys com ETA C15D E TA Power Conditioner SYSTEMS Leading by Design FRONT PANEL FEATURES 10 AC MAINS VOLTAGE AC Mains Function Display AC Mains Voltage Display This display will illuminate when the AC Mains power cord is plugged into an AC source Note the display has a 1 5 tolerance Power On LED Will illuminate green when the AC Mains Power Switch is in the ON Position AC Mains Wiring Polarity Fault Indicator The red LED will illuminate if the AC Mains Power Cord is plugged into an AC Mains outlet that is wired incorrectly such as when the AC Hot and the AC Neutral are wired backwards AC Mains Breaker Indicator This red LED will illuminate if the maximum unit current draw is exceeded The breaker rating is 15A but will handle higher peaks for a short period of time The LED will illuminate until the AC Mains Breaker is reset AC Fault Indicator Although the Dual Clamping Suppression DCS circuit virtually assures protection from most transient voltage spikes and surges nature has a way of occasionally creating electrical forces that are beyond the capabilities of any device to absorb without some degree of damage In the rare instance that this occurs and the DCS circuit has been damaged the red AC Fault LED indicator will illuminate and an internal buzzer will sound The ETA C15D will also shut off permanently until the unit is repaired Note If the AC Fault