Emerson 120V Power Supply User Manual
Contents
1. Utility amber overload Site Wiring symbol Fault RJ 45 jacks 2 lt Fault indicator symbol Network protection AD USB interface s Resettabl EMERSON Liebert PSP circuit Network Power AC Power System e Bo protector Surge outlet 1 NEMA 5 15R Battery backup outlets 3 NEMA 5 15R UPS Status Alarm Conditions and Alerts Battery Mode LED 1 Flashes every 3 seconds Every 3 seconds Battery Replacement LED2 Rea Flashes every 1 second for 5 seconds only Every 1 second for 5 seconds ony Fam _LED2 Rea Sold steady glow unti UPS shuts down afer seconds Continuous unti UPS shuts down REPLACING THE BATTERY Servicing of batteries should be performed or supervised by personnel knowledgeable about batteries and required precautions When replacing batteries replace with the same type and size battery CAUTION A Do not dispose of batteries in a fire The batteries may explode A Do not open or mutilate batteries Released electrolyte is harmful to the skin and eyes It is toxic This product is designed for 120V equipment To replace the battery 1 Turn off all connected loads then turn off the UPS and unplug the input 5 a Electric Shock power cord Batteries are NOT hot swappable 2 Carefully lay the UPS on its left side as shown in the diagram 3 Use a 1 Phillips head screwdriver to remove the four screws from the right side cover then pull up the right side cover
2. Liebert PSP Quick Start Guide 350VA 500VA 120V EMERSON Network Power IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS e Locate the UPS near a wall outlet Do not use an extension cord between the UPS and the outlet This manual contains important instructions that should be followed during installation and e The Liebert PSP has been designed for small office home office use only it is NOT maintenance of the UPS recommended for use in life support applications Intended for installation in a controlled environment e Inthe event of an emergency press the On Off button and disconnect the power cord e Maximum ambient temperature 104 F 40 C from the AC power supply to properly disable the UPS A CAUTION e Do not attach power strips or surge suppressors to the UPS To reduce the risk of fire connect only to a circuit provided with 20 amperes e Do not attempt to service any parts inside the UPS except when replacing the batteries maximum branch circuit overcurrent protection in accordance with the national Failure to adhere to this could cause personal injury or equipment malfunction and void code ANSI NFPA 70 the warranty e Do not connect equipment that may overload the UPS or demand half wave rectification such as a laser printer e Connect the UPS only to an earthed grounded outlet that meets national and local electrical safety guidelines e Send an e mail to upstech emersonnetworkpower com e For t
3. and remove it 4 Remove the black wire from the negative terminal and the red wire from the positive terminal 5 Gently remove the battery from the UPS Attention Risk of Electric Shock 6 Verify that the replacement battery matches the dimensions and battery specification 7 Connect the battery leads to the new battery Be sure to reconnect the red wire to the positive terminal and the black wire to the negative terminal Note Small sparks may occur at the battery connectors during reconnection Take care not to short circuit the positive and negative battery terminals while replacing the battery 8 Place the battery in the UPS 9 Ensure correct alignment of front panel then reattach the right side cover Evenly tighten the four screws from Step 3 Do NOT over tighten screws Dispose of the old battery properly at an appropriate recycling facility TROUBLESHOOTING If the UPS detects a fault consult the table below for possible causes and solutions For further assistance please contact your local Emerson Network Power representative The UPS may not be turned on e Press the On Off button to turn on the UPS Utility power is normal but LED 1 is not illuminated The power cord may not be connected properly e Connect the power cord securely into a wall outlet The upstream input circuit breaker may be tripped e Reset the input circuit breaker Be PASNES Cen EVEI S SECONGS DULINETEIS Battery voltage may b
4. e too low e Recharge the UPS for 8 hours no output power itl seamen is POMNUOUS Y ANOU any The UPS may be overloaded check LED 2 e Disconnect some equipment from the UPS UPS does not provide expected backup time The UPS battery reached end of life e Replace the internal battery The UPS is on and connected to input power but fails m l a l e If utility power is normal try reconnecting input Utility power may be outside the unit s operating range to operate properly power and restarting the UPS SPECIFICATIONS Backup Outlets NEMA 5 15R 3 Surge Outlets NEMA 5 15R 1 Operating Temperature F C 32 to 104 0 to 40 Storage Temperature F C 5 to 104 15 to 40 Operating Storage Relative Humidity 0 90 non condensing EMI Classification FCC Part 15 Class B Agency Safety UL 1778 c UL Listed FCC Part 15 Class B IEC 61000 4 2 Electrostatic discharge IEC 61000 4 3 Radiated E RFI fields EMC IEC 61000 4 4 Fast E transients IEC 61000 4 5 Surges Lightning IEC 61000 4 6 Conducted RFI ANSI C62 41 Category A Level 3 surges Transportation ISTA Procedure 1A Certification Battery run time may vary depending on load The Liebert PSP is compliant with the Restriction of Hazardous Substances Directive ROHS Rongi 2009 Liebert Corporation Technical Support Service United States prohibiting use of six hazardous materials manufacturing of electronics including lead free solder All rights rese
5. echnical support e Visit www liebert com or SETUP Step 1 Inspect the Package Step 5 Check the Site Wiring Fault Indicator e Check the rear of the UPS to make sure the Site Wiring Fault indicator is NOT illuminated Caution If the Site Wiring Fault indicator is illuminated have a qualified electrician check the wall receptacle wiring and fix any problems Inspect the package and the UPS upon receipt Notify the carrier and dealer of visible damage The package includes e Liebert PSP e USB cable e Quick start guide Step 6 Connect the Loads The UPS has three battery backup outlets that The Liebert MultiLink software may be provide power when the UPS operates on bat Uere DATT downloaded from the Liebert Web site at Quick start te Y There is also one surge only outlet see f Figure 2 below multilink liebert com SPS amde l l e Plug the loads into the battery backup outlets See Step 8 for installation instructions on the rear of the UPS a Caution Do not connect a laser printer to the gt lt UPS Step 2 Decide Where to Place the UPS The UPS must be placed indoors protected from water direct sunlight and excessive heat Step 7 Connect the Network Surge Protection The UPS has two network cable jacks for network lines Provide at least 4 100mm of clearance on all sides of the unit see Figure 2 below for proper ventilation e Connect a single line network cable into the network surge prot
6. ection IN jack on the rear of the UPS e Connect a network cable from the OUT jack on the rear Step 3 Charge the UPS Battery Before Use of the UPS to a port on a PC or network device such as a router The UPS battery is not charged before shipping It MUST be charged before use e Connect the UPS power cord to a wall outlet and charge for at least eight hours Unit Step 8 Set Up Liebert MultiLink software can be charged in the on or off state To start using the Liebert MultiLink software Note If battery is placed in storage charge the battery every six months if kept at e Install the software 5 F to 85 F 15 C to 29 C or every three months if kept at 86 F 30 C or higher See the Liebert MultiLink quick start guide or user manual for installation instructions e Connect one end of the USB cable supplied to the USB port on Step 4 Start the UPS the rear of the UPS Connect the other end to a USB port on the isf l computer After the battery is fully charged See the Liebert MultiLink user manual for operating instructions Turn on the UPS by pressing the On Off button see Figure 1 below Note Emerson recommends connecting the USB cable directly to LED 1 should be illuminated green indicating the UPS is operating in Normal Mode the computer WITHOUT using a USB hub UPS CONTROLS AND CONNECTIONS Figure 1 Front Panel LEDs Figure 2 Rear Panel On Off button Overload LED 1 symbol green LED 2 red fault
7. rved throughout the world Specifications subject to change without notice y Liebert is a registered trademark of Liebert Corporation 800 222 5877 Outside U S 614 841 6755 1050 Dearborn Drive RSON Allnames referred to are trademarks or registered trademarks of their respective owners upstech emersonnetworkpower com P O Box 29186 r SL 23285 REVO _ 03 09 Web site www liebert com Columbus OH 43229