Home

Electrolux 335 D Ventilation Hood User Manual

image

Contents

1. con nected to a chimney such as coal or oil room heaters and gas fires in the same room The local decree on fuel burning systems specifies a maximum depression of 0 04 mbar in such rooms Hoods can only be used safely with appliances connected to a chimney if the room and or flat air environment combination is ventilated from outside using a suitable ventilation hole approxi mately 500 600 cm large to avoid the possibility of a depression being created during operation of the hood If you have any doubts contact the relevant controlling authority or building inspector s office Since the rule for rooms with fuel burning appliances is outlet hole of the same size as the ventilation hole a hole of 500 600 cm which is to say a larger hole could reduce the performance of the extractor hood If the hood is used in its recirculation mode it will operate simply and safely in the above conditions without the need for any of the aforementioned measures When the hood is used as an extractor the following rules must be followed to obtain optimal operation short and straight outlet hose keep bends in outlet hose to a minimum never install the hoses with an acute angle they must always follow a gentle curve only keep the hose as large as possible 100 or 120 mm min Failure to observe these basic rules will drastically reduce the performance and increase the noise levels of the extractor hood W
2. the mains power supply before cleaning it Never insert pointed objects in the motor s protective grille Wash the outside surfaces using a mild detergent solution Never use caustic detergents or abrasive brushes or pow ders Only ever clean the switch panel and filter grille using adamp cloth and mild detergents It is extremely important to clean the unit and change the filters at the recommended intervals Failure to do so will cause grease deposits to build up that could constitute a fire hazard Always turn off the electricity before replacing lamps 1 Remove the grid in order to check the lamps and replace them if necessary 2 Unscrew the lamps that do not work and replace them with 40W max lamps E14 If the light does not function check that the lamps are properly screwed in before contacting the AEG Service Dept Attention Failure to observe the instructions on cleaning the unit and changing the filters will cause a fire hazard You are therefore strongly recommended to follow these instructions Technic details Weight 335 D Net 10 8 Kg Maximum connected watt 230 W Motor absorption 150 W Lighting 2 x 40 W E14 Length of the cable 165 cm Extraction rate according to DIN 44971 Min Max Extractor 147 m h 297 m h Recirculating 97 m h 202 m h Special accessories Wall box 120 mm E Nr 647 000 016 Wall box 120 mm 647 000 020 120 mm outlet hose 647 000 012 100 mm outlet h
3. 335 D Extractor Hood Installation and Operating Instructions Contents Description of the appliance General details Extractor version Filter version Safety warnings for kitchen unit installer Electrical connections Safety warnings for electrician Safety warnings for user Hood operation Care and Maintenance Grease filter Active carbon filter Cleaning Replacing the lamps Technic details Special Accessories Technical Assistance Service BW OW O1 O1 10 10 10 11 11 11 Printed on recycled paper AEG putting words into action Description of the appliance 1 Pull out panel 2 Grease filter support grid 3 Hob light 4 Fan speed selector 5 Light switch 0009009090099909000000 O000000000000009000000000000000000000 O00000000090990909TO000000000000000000 O000000000009 NVOO0O000000000000000 000000 9 98988 OO0O0000000000000009 29999999989 SA CZ JBQQQBQ9290 90009 Qe ES BESSER 44 foe Z y yE wo Lo oo AEG General details The hood is supplied as an extractor version but may also be used in the recirculating mode by inserting an active carbon filter Optional extra Exhaust vapours are pushed outwards by means of a pipe Extractor version If the exhaust pipe is in a horizontal position it must be inclined upwards at a angle of 10 so as to guarantee better extraction To connect the fan hood to the wall box we recomm
4. ed intervals Failure to do so could cause grease deposits to build up causing a fire hazard Safety warnings for user Hood operation The control panel of the fan hood is on the front of the appliance see pag 3 The two slide switches are for the various fan functions one is for the fan speed and the other is for the hob light The button with the symbol is used to adjust the fan speed or intensity It is advisable to use low speeds when cooking food that produces an average amount of steam and odour the more steam and odour there is the higher the speed should be The button with the 8 symbol is for switching on and off the hob light aa Moreover the fan hood is equipped with a micro switch which can be found under the lower runner of the pull out panel on the right hand side With this micro switch the appliance may be automatically switched on and off by opening and closing the pull out panel but only if the fan speed has already been set and the light button is turned to I Care and Maintenance Always turn off the appliance before carrying out any repair or maintenance work For safety reasons unplug at the wall socket The purpose of the grease filter is to collect grease particles which form during cooking and it should always be used either in the extraction or recirculation mode You should take out my grease filters every four weeks and wash them either in the dish
5. end the use of venting hoses E Nr 697 000 012 or 647 000 010 120 mm or 100 mm diameter which are supplied as optional extras Filter version Safety warnings for kitchen unit installer Exhaust vapours are purified by means of an active carbon filter Optional extra and directed back into the room To insert the active carbon filter remove the grease filter grid Fit the active carbon filter by inserting it first into the upper hooks and then into the lower ones then lock into position by using the blocking tabs E fig 1 C II ee ee The AEG original KLF 60 80 active filter carbon is necessary for the recirculating mode see paragraph Special accessories The air outlet must not be connected to chimney flues or combus tion gas ducts The air outlet must under no circumstances be connected to ventilation ducts for rooms in which fuel burning appliances are installed It is advisable to apply for authorization from the relevant control ling authority when connecting the outlet to an unused chimney flue or combustion gas duct The air outlet installation must comply with the regulations laid down by the relevant authorities When the unit is used as an extractor version a sufficiently large ventilation hole must be provided with dimensions that are approximately the same as the outlet hole National and regional building regulations impose a number of restrictions on using hoods and fuel burning appliances
6. here flexible ducting is fitted the length should be no more than 3 metres with one 90 bend 2 metres with two 90 bends Bends of more than 90 will reduce the efficiency of the hood and reduce the air flow Electrical connections Please ensure that the voltage and current indicated on the rating plate agree with the voltage of your electricity supply If your appliance has been equipped with a mains lead with a moulded on type plug you must comply with the following regulations The plug moulded on to the lead incorporates a fuse For replacement use a5 amp BS1362 fuse Only ASTA approved or Safety warnings for electrician certified fuses should be used If the fuse cover carrier is lost a replacement cover carried must be obtained from an electrical goods retailer If the socket outlets in your home are not suitable for the plug fitted to the appliance then the plug must be cut off and destroyed for safety reasons and an appropriate plug fitted When wiring the plug ensure that all strands of wire are securely retained in each terminal Do not forget to tighten the mains lead clamp on the plug Electrical connections 230 V using fixed power supply line with plug 240 V using fixed power supply line Great Britain Fuse rating 13 amps The unit should only be connected up by an authorized electrician See rating plate for further information It is recommended that the socket for the plug is si
7. ose 647 000 010 KLF60 80 activated carbon filter 610 899 421 Technical assistance service In case of any enquiries and faults please call AEG After Sales Service AEG Domestic Appliances Limited Head Office 217 Bath Road Slough Berks SL1 4AW Tel 01753 872506 Telefax 01753 512271 AEG Northern Service Centre AEG Scoitish Service Centre Unit 20 Haigh Park Block 11 Unit 1 Haigh Avenue Dundyvan Industrial Estate Stockport Coatbridge GL Manchester SK4 1QR Lanarkshire ML5 4AQ Tel 0161 487 2205 Tel 01236 440387 Telefax 0161 474 1191 Telefax 01236 440256 Service Appointments Bristol 01179 252880 Norfolk 01603 765515 When calling please state the following 1 The model number 2 The E No 3 The F No The manufacturer reserves the right to make alterations in design and colour in the interests of technical development without prior notice 13 AEG Hausgerate AG Postfach 1036 D 90327 Nurnberg Copyright by AEG H 260 287 040 L 509A
8. reen and yellow The wire which is coloured blue must be connected to the terminal which is marked with the letter N or coloured black The wire which is coloured brown must be connected to the terminal which is marked with the letter L or coloured red i BLUE BROWN NEUTRAL LIVE 1i i I o o i e i l O men 2 DP 13A 250V N SUPPLY O T Q Q o GREEN amp YELLOW EARTH The most effective use of the hood is obtained by switching it on a few minutes before you start cooking and leaving it on a for approximately 15 minutes after you have finished thus ensuring all cooking odours are eliminated Never leave a cooking hob or ring on without a pot or pan on top of it to avoid the possibility of excess heat damaging the unit Gas oil or coal cooker flames in particular should never be left uncovered Special care should be taken when using deep fat fryers since the oil in them can overheat and burst into flames The risk of a fat fire increases when using dirty oil It is extremely important to note that overheating can cause a fire Never carry out any flambe cooking under the hood Always disconnect the unit from the power supply before carrying out any work on the hood including replacing the light bulb take the cartridge fuse out of the fuse holder or switch off the automatic circuit breaker lt is very important to clean the hood and the filter at the recommend
9. roceed as follows The whire which is coloured brown must be connected to the terminal which is marked with the letter L or coloured red The wire which is coloured blue must be connected to the terminal which is marked with the letter N or coloured black BLUE BROWN NEUTRAL LIVE Appliances with 2 wires Appliances with 3 wires Your appliance must be connected to fixed wiring via the use of a double pole swiched fused spur outlet with or without pilot lamp We strongly recommend the appliance is connected by a quali fied electrician who is a member of the NICEIC who will comply with the IEE and any local regulations NOTE The terminology DOUBLE POLE means that both the live and neutral supplies are swiched and disconnected at the same time The terminations labelled SUPPLY are for the connection for the internal house wiring and the terminations labelled LOAD are for the appliance WARNING THIS APPLIANCE MUST BE EARTHED IMPORTANT The wires in this mains lead are coloured in accordance with the following code Green Yellow Earth Blue Neutral Brown Live As the colours of the wires in the mains lead of this appliance may not correspond with the coloured markings identifying the terminate in your spur box proceed as follows The wire which is coloured green and yellow must be connected to the terminal which is marked with the letter E or by the earth symbol or coloured green or g
10. ted above the cooker hood or above the overhead cabinet This has 2 advantages 1 The socket is not visible 2 The appliance can easily be unplugged when necessary If a fixed connection is required the cooker hood should be connected by an electrical installer registered with a competent electricity company An isolating device is to be provided on the fixed wiring side Switches with a contact opening of more than 3mm apply as isolating devices These include automatic cut out switches fuses and contactors VDE 0730 s 7 Part1 The hood is fitted with a variable speed motor Your appliance must be connected to fixed wiring via the use of a double pole swiched fused spur outlet with or without pilot lamp We strongly recommend the appliance is connected by a quali fied electrician who is a member of the NICEIC who will comply with the IEE and any local regulations NOTE The terminology DOUBLE POLE means that both the live and neutral supplies are swiched and disconnected at the same time The terminations labelled SUPPLY are for the connection for the internal house wiring and the terminations labelled LOAD are for the appliance IMPORTANT The wires of the mains lead supplied with this appliance are coloured in accordance with the following code Blue Neutral Brown Live As the colours of the flexible cord of this appliance may not correspond with the coloured markings identifying the ter minals in your plug p
11. washer or by hand To remove the filter proceed as follows a remove the grid b take out the dirty filter pushing on the locking devices Z figure 2 c Wash the filters in the dishwasher or by hand Soak grease filters for about one hour in hot water with a grease loosening cleaner then rinse off thoroughly with hot water Repeat the process if necessary Refit the grease filters when they are dry Place grease filters in dish washer Select most powerful washing programme and highest temperature at least 65 C Repeat the process Refit the grease filters when they are dry Whenever the filters are washed clean the grid with warm water and a non abrasive liquid detergent Grease filter Hand washing Dishwasher machine Active carbon filter Cleaning Replacing the lamps This filter is used when the hood functions for internal recycling The original AEG active carbon filter should be used see Special accessories It is neither washable nor reusable In normal cooking conditions we recommend that it be replaced every 4 months To replace the active carbon filter push the locking tabs E inwards and the filter downwards see diagram on pag 4 When ordering a new active carbon filter indicate the model description and fan hood serial number This information can be found on the rating plate inside the appliance Filters can be ordered at any AEG retailer Warning always disconnect the hood from

Download Pdf Manuals

image

Related Search

Related Contents

Vers une réification de l`énergie dans le domaine du logiciel    Synology DS713+  Houseworks, Ltd. 94751 Instructions / Assembly  Hank Converter YPbPr + S/PDIF -> HDMI  CX-1500 Manual - Tangent Communications  Payment Gateway Module - Realex Realauth Redirect  InvisiDoor IDHS20MA Instructions / Assembly  Parrot Minikit +  LIMPIA CRISTALES MPL  